Table 14 ALLOWABLE PRESSURE DROP RATINGS FOR 2700A CAGE CONTROL TRIM GRAFOIL PACKING, FLOW DOWN, No.18 Direct Actuator, 3 to 15 psi Spring Allowable Pressure Drops (PSI) Air Leakage Supply Trim Size Class Pressure 1" 1.5" 2" 3" 4" 6” 8” 18 18 18 20 20 20 22 22 22 24 24 24 27 27 27 30 30 30 33 33 33 36 36 36

II IV & VI V II IV & VI V II IV & VI V II IV & VI V II IV & VI V II IV & VI V II IV & VI V II IV & VI V

1,103 924 56 1,896 1,717 911 2,689 2,510 1,704 3,482 3,303 2,497 4,671 4,492 3,686 5,861 5,681 4,876 7,050 6,871 6,065 7,843 7,664 6,858

998 749

949 654

865 481

679 230

311

175

1,752 1,502 381 2,505 2,256 1,134 3,259 3,009 1,887 4,389 4,140 3,018 5,519 5,270 4,148 6,649 6,400 5,278 7,403 7,153 6,031

1,688 1,393

1,584 1,201

1,301 859

671 283

455 24

2,427 2,132 804 3,166 2,871 1,543 4,275 3,980 2,652 5,384 5,089 3,761 6,492 6,197 4,870 7,232 6,937 5,609

2,304 1,920 171 3,023 2,639 914 4,102 3,719 1,993 5,181 4,798 3,072 6,260 5,877 4,151 6,980 6,596 4,871

1,922 1,481

1,031 643

735 323

2,544 2,103 79 3,477 3,036 1,050 4,410 3,969 1,983 5,343 4,902 2,916 5,965 5,524 3,538

1,391 1,003

1,015 603

1,930 1,542

1,435 1,023

2,470 2,082 336 3,010 2,622 876 3,369 2,982 1,236

1,854 1,443 2,274 1,862 2,554 2,142 290

Usually direct acting actuators use a 3-15 psi spring. With an 18 psi air supply pressure, there is a 3 psi (18-15=3) net closure force on the trim, or for a 27 psi supply the net closure force is 12 psi. If a 6-30 psi spring is used in a direct acting actuator, add 15 to pressure in the air supply column.

ALLOWABLE PRESSURE DROP RATINGS FOR 2700A CAGE CONTROL TRIM GRAFOIL PACKING, FLOW DOWN, No.18 Reverse Actuator Allowable Pressure Drops (PSI) Initial  Leakage Air Trim Size Class Pressure 1" 1.5" 2" 3" 4" 6” 8” 3 3 3 6 6 6 9 9 9 12 12 12 

II IV & VI V II IV & VI V II IV & VI V II IV & VI V

1,103 924 56 2,292 2,113 1,307 3,482 3,303 2,497 4,671 4,492 3,686

998 749

949 654

865 481

679 230

311

175

2,129 1,879 757 3,259 3,009 1,887 4,389 4,140 3,018

2,057 1,762 435 3,166 2,871 1,543 4,275 3,980 2,652

1,944 1,560

1,611 1,170

851 463

595 183

3,023 2,639 914 4,102 3,719 1,993

2,544 2,103 79 3,477 3,036 1,050

1,391 1,003

1,015 603

1,930 1,542

1,435 1,023

The Initial air pressure is actuator diaphragm pressure when the valve begins to open. For example, a 315 has an initial pressure of 3 psi. The spring may have additional compression to provide the 6, 9 & 12 psi initial pressures.

//data/public/pdf/valve-sizing-maual.doc 21 of 43 Norriseal – P.O. Box 40525 Houston TX 77240-052–- Ph: (713) 466-3552, Fax: (713) 896-7386

10/10/2008