FlowScanner Valve Diagnostic User Guide

Page 29

FlowScanner User Guide 5.4.1.1.1

Transducers for Sliding-Stem Valve

Celesco Cable Transducer

W6670

W6673

Celesco Cable Transducers

The long stroke transducer comes in two varietites and can measure up to 25 inches. The 25-inch Celesco is the standard transducer provided in the accessory tool kit. The resolution of this transducer is0.0001 inches. The 50-inch Celesco is also available, with a resolution of 0.001inches. The transducer should be mounted so that stem movement will extend the cable and so that the cable is parallel to the stem. The cable must be securely attached to the feedback arm. The transducer is typically mounted to the actuator casing so the stretching of the yoke legs is detected at shutoff Linear Transducer

W6675

2-inch DRC

The DRC transducer (also available) will measure stem travel less than 2 inches. The resolution of this transducer is .0001. The trans-

29