DVC6200f Menu-Tree Card

Page 1

Field Communicator Menu Tree - DVC6200f Digital Valve Controller RESOURCE BLOCK

FIELDVUEt DVC6200f Digital Valve Controller

Write Lock  Write Lock  Write Priority Configure/Setup  Resource Block Mode  Write Lock  Comm Timeout  Options  Alarm Handling  Identification  Version

www.Fisher.com For the telephone number of the Emerson Process Management sales office nearest you, contact: In North America Fisher Controls International LLC 1 (641) 754–3011 In Latin America Fisher Controls International LLC 1 (314) 746–9900

Top Level  Configure/Setup  Device Diagnostics  Device Variables

In Asia Pacific Emerson Process Management Asia Pacific Private Ltd. (65) 6777–8211

Device Diagnostics  Resource Block Error  Device State  Write Lock  Block Alarm  Maintenance

In Europe Emerson Process Management Ltd. +44 1634 895800

Version  Device Revision  Firmware Revision  Standby Firmware Revision  Hardware Rev  DD Revision  ITK Version Resource Block Error  Other  Block Configuration Error  Simulate Active  Device Needs Maintenance Soon  Memory Failure  Lost Static Data  Lost NV Data  Device Needs Maintenance Now  Power Up  Out of Service Write Lock  Write Alarm Alarm State  Write Lock

For equipment service or support needs, contact your local Emerson Process Management sales office.

Block Alarm  Block Alarm Alarm State  Block Alarm Unacknowledged

475 Field Communicator

Device Variables  Instrument  Options  DD Information

www.Fisher.com D103414X012 March 2010 FIELDVUE and Fisher are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson Electric Co. Emerson, Emerson Process Management, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. EFisher Controls International LLC 2010; All Rights Reserved

Comm Timeout  Shed Remote Cascade  Shed Remote Out

Options  Diagnostic Options  Function Block Options  Miscellaneous Options  Features Available

Maintenance  Restart Actions  Fault State  Set Fault State  Clear Fault State

Options  Diagnostic Options  Function Block Options  Miscellaneous Options  Features Available  Features Selected Alarm Handling  Alert Key  Confirm Time  Limit Notify  Maximum Notify  Block Alm Disabled  Block Alarm Auto Acknowledge  Disc Alm Disabled  Discrete Alarm Auto Acknowlege Identification  Device ID  Electronics Serial Number  Factory Serial Number  Field Serial Number  Tag Description  Strategy  Manufacturer  Device Type  Diagnostics Options

Instrument  Identification  Version

Miscellanous Options  Firmware Download  Travel Control Capable  Pressure Control Capable  Pressure Fallback Capable

Features Available  Reports  Fault State  Soft W Lock  Multi‐bit‐Alarm (Bit‐Alarm) Support

Function Block Options  AO  DO  AI  DI  PID  IS  OS  MAI Miscellaneous Options  Firmware Download  Travel Control Capable  Pressure Control Capable  Pressure Fallback Capable

Menu Tree applies to: Device Revision Hardware Revision 2

8

Firmware Revision

DD Revision

2.0

2

TALK TALK

Features Available  Reports  Fault State  Soft W Lock  Multi‐bit‐Alarm (Bit‐Alarm) Support Features Selected  Reports  Fault State  Soft W Lock  Multi‐bit‐Alarm (Bit‐Alarm) Support Identification  Device ID  Electronics Serial Number  Factory Serial Number  Field Serial Number  Tag Description  Strategy  Manufacturer  Device Type Version  Device Revision  Firmware Revision  Standby Firmware Revision  Hardware Rev  DD Revision  ITK Version Function Block Options  AO  DO  AI  DI  PID  IS  OS  MAI

Attach the Field Communicator to the TALK Connections inside the DVC6200f Digital Valve Controller Terminal Box


TRANSDUCER BLOCK Basic Setup  Device Setup  Performance Tuner

Configure/Setup  Basic Setup  Detailed Setup  Calibration

Top Level  Configure/Setup  Device Diagnostics  Device Variables

Device Diagnostics  Active PlantWeb Alerts  Alert Conditions  Status  Device Record  Stroke Valve  Trend Device Variables  All Block Modes  AO Control - Pre‐Char  AO Control - Post‐Char  DO Control  Input Characterization  :Travel/Pressure State  :PD Inside Status  Protection  Drive Signal  Temperature  Cycle Counter  Travel Accumulator  :Travel Count  Pressures

Response Control  Travel Tuning  Pressure Tuning  Travel Pressure Control  Input Characterization  Custom Characterization Table  Outblock Selection

Detailed Setup  Transducer Block Mode  Protection  Response Control  Alerts  Instrument  Valve and Actuator  MAI Channel Map  Alert Handling

Calibration  Auto Calibration  Manual Calibration  Relay  Travel Sensor  Supply Pressure  Pressure A  Pressure B

MAI Channel Map  :MAI Channel 1  :MAI Channel 2  :MAI Channel 3  :MAI Channel 4  :MAI Channel 5  :MAI Channel 6  :MAI Channel 7  :MAI Channel 8

Travel Pressure Control  :Travel/Pressure State  :Travel/Pressure Select  Travel Deviation Pressure Fallback  Travel Cutoff Hi  Travel Cutoff Lo  :Pressure Cutoff Open  :Pressure Cutoff Closed  :Pressure Range Hi  :Pressure Range Lo

Instrument  Tag Description  Pressure Units  Temperature Units  Travel Units  Length Units  Area Units  Spring Rate Units  :Relay Type  :Zero Power Condition  :Maximum Supply Pressure  Calibration Person  Calibration Location  Calibration Date  :Last Calibration Type

Alerts  Elect Alerts  Configuration Alerts  Sensor Alerts  Environment Alerts  Travel Alerts  Prox Alerts  Travel History Alerts  Performance Alerts  PlantWeb Alert Enable  PlantWeb Alert Reporting

Pressure Tuning  :Pressure Tuning Set  :Pressure Proportional Gain  :Pressure MLFB Gain  :Pressure Integral Gain  :Pressure Integral Dead Zone  :Pressure Integral Limit Hi  :Pressure Integral Limit Lo

Travel Tuning  :Travel Tuning Set  Travel Proportional Gain  Travel Velocity Gain  :Travel MLFB Gain  :Travel Integral Enable  :Travel Integral Gain  :Travel Integral Dead Zone  :Travel Integral Limit Hi  :Travel Integral Limit Lo  Performance Tuner  Stabilize / Optimize

Elect Alerts  Drive Current  Drive Signal  Processor Impaired

PlantWeb Alert Enable  Failed Enable  Maintenance Enable  Advise Enable

Valve and Actuator  Valve  Trim  Actuator  Reference Reference Alert Handling  :Trim Style 1  PlantWeb Alert Simulate Simulate Active Alerts  :Trim Style 2  Simulate Active Alerts  Failed Active  :Stroke Time Open  PlantWeb Alert Handling  Maint Active  :Stroke Time Close  Advise Active Self Test Status PlantWeb Alert Handling  Integrator Suspended  PlantWeb Alerts Set PV Status  Integrator Limited Lo  Block Error Reporting  Integrator Limited Hi AO Control - Pre‐Char  Travel Sensor Span Error  :Setpoint  MLFB Error  :Setpoint Status  Travel Sensor Hi Error  :Travel (DeChar)  Travel Sensor Lo Error  Pressure B Sensor Failure Status AO Control - Post‐Char  Pressure A Sensor Failure  Self Test Status  :Travel Target  Supply Sensor Failure  Block Error  :Travel  IOP Failure  :Travel Status  Drive Current Alert Device Record  Simulate Jumper ON  :Maximum Recorded Temperature DO Control  :Maximum Recorded Temperature Time  :Setpoint(D) Block Error  :Minimum Recorded Temperature  :Travel(D)  Block Configuration Error  :Minimum Recorded Temperature Time  Simulate Active Pressures  :Maximum Recorded Supply Pressure  Lost Static Data  :Supply  :Maximum Recorded Supply Pressure Time  Device Needs Maintenance Now  :Pressure A  :Minimum Recorded Supply Pressure  Out of Service  :Pressure B  :Minimum Recorded Supply Pressure Time  :A Minus B

Drive Current  Drive Current  :Drive Current  :Drive Current  :Drive Current  :Drive Current  :Drive Current  :Drive Current

Drive Signal  Drive Signal  :Drive Signal Alert  :Drive Signal Alert Enable

PlantWeb Alert Reporting  Failed Suppress  Maintenance Suppress  Advise Supress

Valve  Valve Manufacturer  Valve Model Number  Valve Serial Number  Valve Style  :Valve Size  :Valve Class  :Rated Travel  :Actual Travel  :Shaft Stem Diameter  :Packing Type  :Inlet Pressure  :Outlet Pressure

Actuator  Actuator Manufacturer  Actuator Model Number  :Actuator Style  Actuator Serial Number  :Actuator Size  Actuator Fail Action  :Feedback Connection  :Travel Sensor Motion  :Lever Style  :Level Arm Length  :Effective Area  :Air  :Upper Bench Set  :Lower Bench Set  :Nominal Supply Pressure  :Spring Rate

Alert Alert Enable Shutdown Manual Recovery Alert Point Alert Time

Prox Alerts  :Travel  Travel Open  Travel Closed  Proximity

Processor Impaired  :Program Memory Alert  :Program Memory Alert Enable  :Program Memory Shutdown  :Program Memory Manual Recovery  :Static Memory Alert  :Static Memory Alert Enable  :Static Memory Shutdown  :Static Memory Manual Recovery  :Processor Alert  :Processor Alert Enable  :I/O Processor Alert  :I/O Processor Alert Enable  :I/O Processor Shutdown  :I/O Processor Man Recovery

Travel Alerts  :Travel Target  :Travel  Travel Deviation  Travel Limit  Travel Hi/Lo Travel Open  :Travel Open  :Travel Open  :Travel Open  :Travel Open

Alert Alert Enable Alert Point Deadband

Travel Closed  :Travel Closed  :Travel Closed  :Travel Closed  :Travel Closed Trim  :Seat Type  :Leak Class  :Port Diameter  :Port Type  :Flow Direction  :Push Down To  :Flow Tends To  :Unbalanced Area

Proximity  :Proximity  :Proximity  :Proximity  :Proximity  :Proximity  :Proximity  :Proximity  :Proximity

Alert Alert Enable Alert Point Deadband

Hi Hi Alert Hi Hi Alert Enable Hi Alert Hi Alert Enable Lo Alert Lo Alert Enable Lo Lo Alert Lo Lo Alert Enable

Performance Critical  Performance Critical Alert  Performance Critical Alert Enable Performance Alerts  :PD Inside Status  :PD Run  Performance Critical  Performance Reduced  Performance Information

Performance Reduced  Performance Reduced Alert  Performance Reduced Alert Enable Performance Information  Performance Information Alert  Performance Information Alert Enable

Output Block Timeout  :Output Block Timeout  :Output Block Timeout  :Output Block Timeout  :Output Block Timeout  :Output Blk Timeout

Configuration Alerts  Output Block Timeout  Blocks Set to Default  Alert Key

Blocks Set to Default  :Blocks Set to Defaults Alert  :Blocks Set to Defaults Alert Enable

Sensor Alerts  Travel Sensor  Pressure Sensors  Pressure Fallback  Temperature Sensor

Travel Sensor  :Travel Sensor  :Travel Sensor  :Travel Sensor  :Travel Sensor

Environment Alerts  Supply Pressure  Temperature Limit

Pressure Sensors  :Pressure A Sensor Alert  :Pressure A Sensor Alert Enable  :Pressure A Sensor Shutdown  :Pressure A Sensor Manual Recovery  :Pressure B Sensor Alert  :Pressure B Sensor Alert Enable  :Supply Pressure Sensor Alert  :Supply Pressure Sensor Alert Enable

Travel Deviation  Travel Deviation  :Travel Deviation  :Travel Deviation  :Travel Deviation  :Travel Deviation  :Travel Deviation

Alert Alert Enable Alert Point Time Deadband

Temperature Sensor  :Temperature Sensor Alert  :Temperature Sensor Alert Enable Supply Pressure  :Supply  :Supply Pressure Hi Alert  :Supply Pressure Hi Alert Enable  Supply Pressure Hi Alert Point  :Supply Pressure Lo Alert  :Supply Pressure Lo Alert Enable  :Supply Pressure Lo Alert Point

Travel Hi/Lo  :Travel Hi Alert  :Travel Hi Alert Enable  :Travel Hi Alert Point  :Travel Hi Deadband  :Travel Lo Alert  :Travel Lo Alert Enable  :Travel Lo Alert Point  :Travel Lo Deadband Cycle Counter  Cycle Counter  :Cycle Counter  :Cycle Counter  :Cycle Counter  :Cycle Counter

Alert Alert Enable Shutdown Manual Recovery

Pressure Fallback  :Pressure Fallback Alert  :Pressure Fallback Alert Enable

Travel Limit  :Travel Hi Hi Alert  :Travel Hi Hi Alert Enable  :Travel Hi Hi Alert Point  :Travel Hi Hi Deadband  :Travel Lo Lo Alert  :Travel Lo Lo Alert Enable  :Travel Lo Lo Alert Point  :Travel Lo Lo Deadband

Travel History Alerts  Cycle Counter  Travel Accumulator

Alert Alert Enable Shutdown Manual Recovery

Temperature Limit  Temperature  :Temperature Hi Alert  :Temperature Hi Alert Enable  Temperature Hi Alert Point  :Temperature Lo Alert  :Temperature Lo Alert Enable  :Temperature Lo Alert Point Alert Alert Enable Alert Point Deadband

Travel Accumulator  Travel Accumulator  :Travel Accumulator  :Travel Accumulator  :Travel Accumulator  :Travel Accumulator

Alert Alert Enable Alert Point Deadband


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.