Instrument Level AC Fast‐Key Sequence

Coordinates(1)

1‐1‐2‐2‐4

4‐C

1‐3‐1

3‐F

Analog Input Range Hi

1‐2‐2‐2

4‐E

Analog Input Range Lo

1‐2‐2‐3

4‐E

Analog Input Units

1‐2‐2‐1

4‐E

1‐1‐2‐3‐4

4‐D

1‐3‐2

3‐F

1‐1‐1‐3

3‐C

1‐3‐5

3‐G

Date

1‐2‐1‐4

3‐D

Descriptor

1‐2‐1‐3

3‐D

2‐2

2‐F

Function/Variable Actuator Style Analog Input Calibration

Auto Travel Calibration Calibration Location

Device Description Revision Device Identification Device Revision

2‐1‐6 2‐1‐2

Fast‐Key Sequence

Coordinates(1)

1‐1‐2‐3‐2‐2

6‐D

1‐2‐3‐4‐1‐2

5‐H

Pressure Range Hi

1‐2‐3‐5‐1

4‐G

Pressure Range Lo

1‐2‐3‐5‐2

4‐G

1‐1‐2‐3‐2‐1

6‐D

1‐2‐3‐4‐1‐1

6‐G

1‐1‐2‐2‐2

4‐C

Function/Variable Pressure Proportional Gain

Pressure Tuning Set Pressure Units

1‐2‐2‐4

4‐E

Protection

Hot Key‐2

1‐B

1‐1‐1‐2

3‐B

Relay Adjust

1‐1‐2‐3‐3

4‐D

1‐3‐6

3‐G

3‐H

Relay Type

1‐2‐4

3‐E

3‐G

Restore Factory Settings

1‐3‐4

3‐F

1‐1‐1‐1

3‐D 6‐F

1‐1‐2‐2‐5

4‐C

Setup Wizard

Firmware Revision

2‐1‐3

3‐G

Travel Integral Gain

1‐2‐3‐2‐3

Hardware Revision

2‐1‐4

3‐G

Travel Integral Enable

1‐2‐3‐2‐2

6‐F

1‐2‐1‐1

3‐D

1‐1‐2‐3‐1‐4

6‐C

2‐1‐1

3‐G

1‐2‐3‐6

4‐F

2‐1‐5

3‐H

Hot Key‐1

1‐B

Travel Proportional Gain

1‐1‐2‐1

3‐C 3‐D

Feedback Connection

HART Tag HART Universal Revision Input Characterization Instrument Level Instrument Mode Instrument Serial Number Integral Dead Zone Integral Limit

1‐2‐1‐6 1‐2‐3‐3‐1 1‐2‐3‐3‐2

6‐F 6‐F

Manual Travel Calibration

1‐3‐3

3‐F

Maximum Supply Pressure

1‐1‐2‐2‐3

4‐C

Travel MLFB Gain Travel / Pressure Select

1‐2‐3‐2‐1‐4

6‐E

1‐1‐2‐2‐1

4‐C

1‐2‐3‐1

4‐F

1‐1‐2‐3‐1‐2

6‐C

Travel Sensor Adjust

1‐3‐7

3‐G

Travel Sensor Motion

1‐1‐2‐2‐6

4‐C

1‐1‐2‐3‐1‐1

6‐C

Travel Tuning Set Travel Velocity Gain

1‐2‐3‐2‐1‐1

6‐E

1‐1‐2‐3‐1‐3

6‐C

1‐2‐3‐2‐1‐3

6‐E

1‐2‐1‐5

3‐D

Message

1‐2‐1‐2

3‐D

Valve Serial Number

Polling Address

1‐2‐1‐7

3‐E

Valve Style

1‐1‐2‐2‐7

4‐C

Pressure Integral Control Enable

1‐2‐3‐4‐2

6‐G

Zero Power Condition

1‐1‐2‐2‐8

4‐C

Pressure Integral Gain

1‐2‐3‐4‐3

6‐G

1‐1‐2‐3‐2‐3

6‐D

1‐2‐3‐4‐1‐3

5‐H

Pressure MLFB Gain