DK-Lok Tube Fittings Catalog, Complete

Page 17

Dk-Lok

Tube Fittings

'Bulkhead Retainer

IDBR Body

Jam Nut

Hex

Port B

Port A

Bulkhead retainer acts as a backup wrench on panel construction. This allows one person to tighten the jam nut on port A side and following tubing connection on port A and B without a backup wrench.

Connects fractional tube

If

Dk-Lok

Part No.

O.D.

B

C

0

E

F

Drive Screw

Number

9.52 12.7 14.28 15.87

7.94

3.18

7.94

31

3.18 3.18

10.31

#6-318

31

11.90

3.97 3.97 3.97

#6-3/8

12.7 14.28

3.97 5.55 6.35

#6-318

31

15.87 17.46

3.18 3.18

12.7

7.14 7.94

18.0

3.18 3.18

#6-3/8 #6-3/8 #6-3/8 #6-3/8 #10-1/2 #10-1/2 #10-1/2 #10-1/2 #10-1/2 #10-1/2

31

14.28 14.28

3.97 3.97 3.97 3.97 5.55 5.55 5.55 5.55 5.55 5.55

mm

in

DBR-1-S DBR-2-S DBR-3-S DBR-4-S DBR-5-S DBR-8M-S DBR-6-S DBR-10M-S DBR-8-S DBR-10-S DBR-12-S DBR-14-S DBR-16-S

A

1/16 1/8

3/16

3M.4M

1/4

6M

5/16

17.46 17.46 19.05

8M

3/8 10M

23.81

1/2

12M

23.81

5/8

15M.16M

314

18M

25.4 26.98

28.57 32.54

7/8 1

19.05

22.0 23.81 26.98

3.18

30.16

3.18

33.33 41.27

3.18

3.18 3.18

3.18

7.94 8.73

15.87 19.05 19.05

10.31

20.64 23.02 26.19 29.37

10.31

10.31

11.90 13.49 14.28

31 31 31

27 27 27 27

27 27

Dril Hol Dia

3.05 3.05 3.05 3.05 3.05 3.05 3.05 3.66 3.66 3.66 3.66 3.66 3.66

Bulkhead Elbow Union

DBL

Connects metric tube Width across flat

E

Tube 0.D. (rnm)

Min.

h

h,

H

6

4.8

15.8

14.2

14.0

15.3

17.7

36.5

20.6

8

6.4

17.4

17.4

16.0

18.6

10

7.9

22.0

22.0

19.0

19.5

46.0 48.5

23.2 26.9

DBL-12M DBL-16M

12

9.5

23.8

50.8

13.5

22.0 25.0

22.0

16

24.0 27.0

40.9 44.5 46.9

22.0

52.3

DBL-20M DBL-25M

20

15.9 21.8

34.9 41.0

35.0

32.0 38.0

26.0 31.3

22.0 26.5

Part No. DBL-6M DBL-8M DBL-10M

25

Oklisah Oarporatkm

27.0

41.0

A

Panel Panel Hole Max Drill size Thickness

L

Li

43.9 48.4

30.0

11.5

10.2

13.1

11.2

52.1

30.7 34.5

16.2

11.2

26.9

57.0

37.0

19.5

12.7

53.5

34.1

63.7

44.5

22.8

12.7

68.4 74.2

39.0

78.2 86.5

48.7 58.4

29.0

17.0

331

19.1

11

46.1

All dimensions are in millimeters unless otherwise specified and only for reference subject to change.

16

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
DK-Lok Tube Fittings Catalog, Complete by RMC Process Controls & Filtration, LLC. - Issuu