1850 Level Control Specification, Order Code & Parts Manual

Page 1

Section No. 13.1

Series

1850

1850 Float Nose Application The WellMark Float Nose is an inexpensive mechanical lever control that provides convenient vessel access. The 7" x 12" float provides sufficient lift torque to operate WellMark’s near-balanced 1250 Series lever valve as well as other industry balanced valves. The float nose is widely used as an oil or water dump control on separators, water knockouts, horizontal emulsion treaters, and other similar accumulators.

Features • 500 psi Working Pressure, Std. • Cast Steel Float Nose, Std. • Cast Steel Hammer Union Ring, Std. • ACME Thread for Long Wear

Dimensional Data 8 3/8 (w/8"X5" Weld Neck) 11 3/8 (w/8"X8" Weld Neck)

Installation

8" Union Type

3 3/8

14"

6 1/2 Dia. 6" Dia.

1/2

WellMark Float Nose

18" Std.

Max. Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . 500 psi Materials Float Nose . . . . . . . . . . . . . . . . . . . . . . . . . WCB Cast Steel Hammer Union . . . . . . . . . . . . . . . . . . . . . . WCB Cast Steel Stuffing Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steel Stem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 S.S. Float . . . . . . . . . . . . . . . . . . . . . . . . . 7" x 12" Plated Steel (3/8" NPT Connection) Weld Neck . . . . . . . . . . . . . . . . . . Sch. 100 A106 GR. B Pipe

14"

11 1/2

Specifications

WellMark Lever Operated Oil Valve

14"

8"-150 Flange Type

The

18" Std.

13 1/2

4"

18" Std.

6" Weld Type

Company, L.L.C. • Oklahoma City, Oklahoma • Tel: (405) 672-6660 • Fax: (405) 672-6661 • wellmarkco.com

©2002 The WellMark Company • Litho USA • WM1850-10/02 • All registered trademarks are the property of their respective owners.