0138ws016e non cbi report

Page 11

Model: Q-Tee II Steel RAIS A/S Industrivej 20, Vangen DK-9900 Frederikshavn Denmark

Table 7 – Dilution Tunnel Gas Measurements and Sampling Data Summary Average Dilution Tunnel Gas Measurements Run

Length of Test (min)

Velocity (ft/sec)

Flow Rate (dscf/min)

Temperature (°F)

1

N/A*

N/A*

N/A*

N/A*

2

112

14.13

158.4

91

3

134

14.30

161.3

85

4

59

14.21

150.9

119

5

N/A*

N/A*

N/A*

N/A*

6

111

13.10

146.7

90

7 154 13.44 152.1 *No results computed due to ceased combustion prior to test completion

83

Table 8 - Average Temperature Data Run

Beginning Surface Temperature Averagea

Ending Surface Temperature Averagea

Surface Delta Tb

1

319.2

N/A*

N/A*

2

410.9

319.4

91.5

3

413.1

301.6

111.5

4

392.8

422.6

29.8

5

304.1

6

364.3

N/A* 326.3

N/A* 38.0

7 351.1 270.1 81.0 a. All temperatures are in degrees F. b. Represents the difference between beginning and ending average surface temperatures. *No results computed due to ceased combustion prior to test completion