Sample Property Inspection Report

Page 1

PropertyInspection Report SouthwestPropertyInspection 123ABCDr. SanDiego,CA92067
TableofContents Definitions 2 GeneralInformation 2 LotsandGrounds 3 ExteriorSurfaceandComponents 3 Roof 5 Garage 6 Plumbing 8 Electrical 9 LaundryRoom/Area 11 Attic 11 Structure 12 Fireplace 13 AirConditioning 13 HeatingSystem 15 Bathrooms 17 Bedrooms 19 LivingSpace 20 Kitchen 20 InspectionAgreement 23 Summary 32 SouthwestPropertyInspection Page1of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Definitions NOTE:Alldefinitionslistedbelowrefertothepropertyoritemlistedasinspectedonthisreportatthetimeofinspection. A Acceptable Functionalwithnoobvioussignsofdefect. NINotInspectedItemwasunabletobeinspectedforsafetyreasonsorduetolackofpower,inaccessible,ordisconnectedat timeofinspection. M Maintenance Itemisnotfullyfunctionalandrequiresrepairorservicing. HSHealth&SafetyItemneedsimmediaterepairorreplacement.Itisahealthand/orsafetyconcerntotheoccupants. GeneralInformation PropertyInformation PropertyAddress123ABCDr. CitySanDiegoStateCAZip92067 ClientInformation ClientNameBob&JoanneSmith InspectionCompany InspectorNameSteveLindsey CompanyNameSouthwestPropertyInspection Phone866-302-2387 E-Mailsteve@southwestinspect.com Conditions OthersPresent:Buyer,Buyer'sagentPropertyOccupied?No InspectionDate11/25/2013 StartTime:10:00EndTime:1:00 ElectricOn Yes No NotApplicable Gas/OilOn Yes No NotApplicable WaterOn Yes No NotApplicable Temperature75 Weather:SunnySoilConditions:Dry SpaceBelowGradeNone BuildingType:Singlefamilyhome-TwostoryGarage:Attached YearBuilt1991 Approx.SquareFeet2405 SouthwestPropertyInspection Page2of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

LotsandGrounds

ANIMHS scopeofthisinspection.Aqualifiedlicenseddrainspecialistshouldbeconsulted,priortocloseof escrow,toevaluatethesystem. LawnSprinklers:Note:Thelandscapingirrigationsystemwasnottestedorevaluated.Beyondthe scopeofthisinspection.Aqualifiedlicensedlandscapingcontractorshouldbeconsultedifan evaluationoftheirrigationsystemisdesired.

ExteriorSurfaceandComponents

Note:Regardingtheweatherprotectionatwindows,doors,andslidingglassdoorunits,itisnotuncommonfor Thisinspectionwasconductedbyvisualmeansonlyandthecurrentconditionand/orappropriateinstallationof concealedmoisturebarriers/flashingsatexteriorsiding,doors,windows,balconies,decks,walks,stairs, driveways,exteriorcomponentsorpenetrationscannotbeconfirmed-Pleaserefertoitems12and13inPartIII underLimitations,ExceptionsandExclusionsoftheCREIAStandardsofPractice.

ANIMHS

ExteriorSurface Type:StuccoCheckcrackingpresent. Fascia:WoodRefertothepestcontrolreport. Refertothepestcontrolreport.

A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety
1. Walks:Concrete 2. Steps/Stoops:Compositematerial 3. Patio:Concrete 4. Porch:Concrete 5. Vegetation:Trees,Shrubs 6. Grading:Level 7. Swale:Adequateslopeanddepthfordrainage 8. SurfaceDrains:Note:Theoutsideareadrainswerenottestedforfunctionaldrainage.Beyondthe
9. Driveway:Concrete 10. Fences:Wood 11.
moistureinfiltrationtooccurintothebuilding'sinteriorduringrainyweatherregardlessoftheageoftheproperty-
A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety
1.
2.
3. Eaves:Wood
SouthwestPropertyInspection Page3of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

ExteriorSurfaceandComponents(Continued)

4. DoorBell:Thedoorbellisinoperative.Repairsbyaqualified licensedcontractorarerecommended. 5. EntryDoor:Wood 6. PatioDoors:Vinylsliderwithdual-paneglassThepatio screendoorsaremissing.Recommendreplacement. Repairsbyaqualifiedlicensedcontractorarerecommended. 7. Windows:Moistureandfoggingwerenotedinthedual-paneglassofthewindowsinthefollowing locations:2ndfloormaster,2ndfloorguestbedroomandoveropenareaabove(Defectivehermetic seals.)Repairsbyaqualifiedlicensedwindowcontractorarerecommended. Note:Duetoclimaticconditions,thenatureofthecomponents,andthecleanlinessoftheglass,itis notpossibletodetermineallofthefailurespresent.Evaluationoftheremainingwindowsinthe homebyaqualifiedlicensedglazingcontractorisrecommendedpriortoremovalofpurchase contingencies. SouthwestPropertyInspection Page4of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
ExteriorSurfaceandComponents(Continued) Windows:(continued) 8. Window/DoorScreens: 9. ExteriorLighting:Loosewiringandbulbassemblysideof garage.Repairsbyaqualifiedlicensedelectricianare recommended. 10. ExteriorElectricOutlets:110VACGFCI 11. HoseBibs: 12. GasMeter:AccessibleNote:Thegasmeterislocatedatthesideofthegarage.Installationofan emergencyshut-offwrenchisrecommended-Nonepresent. Roof Note:Thisroofinspectionreportsonthetypeandconditionoftheroofingmaterials,missingand/ordamaged materials,andattachments(excludingsolarsystems,antennas,etc.)wherevisible.Thisdoesnotconstitutea warranty,guarantee,roofcertification,orlifeexpectancyevaluationofanykind.Roofsarenotwatertestedfor leaks.Theconditionoftheroofingunderlaymentmaterialwasnotverified/inspected.Forfurtherevaluationand aroofcertification,werecommendyouconsultaqualifiedlicensedroofingcontractor.Buildingsthathavetileor woodshingle/shakematerialsandaregoingtobetentedfortermitesshouldbereinspectedforpossibledamage causedbytheexterminationprocessbeforethecloseofescrow. A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS SouthwestPropertyInspection Page5of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Roof(Continued) RoofSurface 1.MethodofInspection:Ontheroof 2. UnabletoInspect:75%Note:The2ndstoryroofwasinaccessibleduetoitsheight.Alimited visualinspectionwasdonefromthegroundusingbinoculars.Unseendefectsmayexist.Aqualified licensedroofingcontractorshouldbeconsultedforacompleteevaluation. 3. Material:Concretetile-Flatprofile 4.Type:Gableroof 5. Flashing:Galvanizedsteel 6. Valleys: MainChimney 7. Chimney:Stuccoandframecoveredthree-wallpipe 8. Flue/FlueCap:Metalw/sparkarrestor 9. ChimneyFlashing:Galvanizedsteel 10. PlumbingVents:ABS Garage A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS Garage 1.TypeofStructure:AttachedCarSpaces:2 2. GarageDoors:Metal-sectionalroll-up 3. DoorOperation:Mechanized SouthwestPropertyInspection Page6of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

4. DoorOpener:LiftMasterThepressuresensorsafety reversingsystemonthegaragedooropenerrequires adjustment.Thedoordoesnotreversewhenanobject blocksitspath-Safetyhazard.Repairsbyaqualified licensedgaragedoorcontractorarerecommended.

5. FireDoor:Fire-rated,Self-closingClosingmechanism inoperativeonthegaragefiredoor(leadingintothehouse) causingabreachinthefire-resistant-ratedassembly betweenthegarageandthehouse-Firehazard.Repairsby aqualifiedlicensedcontractorarerecommended. SideDoor:Metal 8. Ceiling:DrywallThereareunrepairedholesinthegarage ceilingcausingabreachinthefire-resistant-ratedassembly betweenthegarageandthehouse-Firehazard.Thereisan unrepairedholeinthegarageceilingcausingabreachinthe fire-resistant-ratedassemblybetweenthegarageandthe house-Firehazard.

9. Floor/Foundation:Concreteslab

Garage(Continued)
6.
7. Walls:
SouthwestPropertyInspection Page7of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Garage(Continued) 10. Electrical:110VACGFCIoutlets,LightingWiringforfront lightsrunoffoflightswitch,recommendaddseparate junctionbox,Evaluationbyaqualifiedlicensedelectricianis recommended. Plumbing A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1. WaterServiceLine:Underground 2. MainWaterShutoff:GarageNote:Shut-offvalveswerenottested.Beyondthescopeofthis inspection. 3. WaterPressure:100PSIThewaterpressureisexcessive. Excessivewaterpressurecancausedamageandleaksat theplumbingcomponents.Recommendhavingaqualified licensedplumberreducethewaterpressureto40-80PSI. 4. WaterLines:Copper 5. DrainPipes:ABS 6. ServiceCaps:Accessible 7. VentPipes:ABS 8. GasServiceLines:SteelNote:Asedimenttrapisnotinstalledonthegassupplylinesforthe waterheaterandfurnace.Thismayvoidthemanufacturer'swarrantyontheappliancesandmay causedamageormalfunctionoftheunits.Refertothemanufacturer'sinstallationinstructionsandto thelocalauthorityhavingjurisdictionastowhetherornotoneisrequired. GarageWaterHeater 9. WaterHeater:Functional 10.Type:Naturalgas-FVIRCapacity:50Gallon 11. SeismicStrapping:Installed SouthwestPropertyInspection Page8of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Plumbing(Continued) 12. VentPipe:B-vent 13. TPRValve/DischargeLine:TheTPRvalvedoesnothaveadischargelineinstalled-Safetyhazard. Repairsbyaqualifiedlicensedplumberarerecommended. Electrical Note:Theelectricalservicepanelislocatedattheexteriorgaragewall. A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1.ServiceSizeAmps:200Volts:120/240VAC 2. Service:Underground 3. 110VACBranchCircuits:Copper 4. 220VACBranchCircuits:Copper 5. ConductorType:Non-metallicsheathedcable 6. GFCI:Exterior,garage,kitchen,bathrooms 7. Grounding:Foundationsteel 8. Bonding:Waterpiping 9. SmokeDetectors:Hallways,Bedrooms 10. CarbonMonoxideDetectors:Thereisnotacarbonmonoxidedetectorinstalledinthehome. (Requiredoutsideofthesleepingareasintheimmediatevicinityofthebedrooms,andoneachlevel ofthehome.)Safetyhazardtotheoccupants.Installationisadvisedinaccordancewithcurrent applicablestateandlocalregulations,andintheinterestofoccupantsafety. 11. SecuritySystem:Note:Thesecuritysystemanditscomponentswerenotinspected.Beyondthe scopeofthisinspection. ElectricPanel SouthwestPropertyInspection Page9of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Electrical(Continued) 12. Manufacturer:Cutler-HammerThehingesarelooseontheelectricpanelcover.Thecoverfallsoff. Waterentrymayoccur.Fire/Shockhazard.Repairsbyaqualifiedlicensedelectricianare recommended. 13.MaxCapacity:225Amp 14. MainBreakerSize:200Amp 15. Breakers:Identified 16.Isthepanelbonded? Yes No SouthwestPropertyInspection Page10of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
LaundryRoom/Area Note:Thelaundryconnectionswereinspectedbyvisualmeansonly.Thewatersupplyandwastelinepiping thatisconcealedwithininaccessibleareassuchascoveredwallsandconcreteslabfloorswasnotevaluated. Thewashingmachine,clothesdryer,andanylaundryequipmentwasnotoperatedorevaluatedaspartofthis inspection.Itisadvisedtoconsultwiththecurrentownertoconfirmtherearenocurrentorpreviousproblems withthelaundrysupplyandwastepipingbeforethecloseofescrow. A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1stFloorLaundryRoom/Area 1. Ceiling:Drywall 2. Walls:Drywall 3. Floor:Tile 4. Electrical: 5. WasherHoseBib:Thehotandcoldwatervalvesare leaking.Repairsbyaqualifiedlicensedplumberare recommended. 6. DryerVent:Metalduct 7. WasherDrain:Standpipe Attic Note:Theatticaccessislocatedinthe2ndfloorhallway. A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS Attic 1.MethodofInspection:Intheattic 2. Access:Wooddoor SouthwestPropertyInspection Page11of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Attic(Continued) 3. RoofFraming:Woodtruss 4. Sheathing:O.S.B. 5. Ventilation:Gableandeavevents 6. Insulation:Blownin,Fiberglass 7. InsulationDepth:Approx.91/2" 8. Wiring/Lighting:110VAClightingcircuit Structure A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1. StructureType:Woodframe 2. Foundation:ConcreteslabNotfullyvisible. 3. BearingWalls:Woodframe 4. FloorJoists: 5. Floor/Slab:Notfullyvisibleduetofloorcoverings. 6. Stairs/Handrails:Woodstepswithwoodhandrails SouthwestPropertyInspection Page12of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

Fireplace

Note:Thisinspectionofthefireplace/chimneyislimitedtothereadilyvisibleportions.Theinnerreachesofa chimneyfluearenotvisuallyaccessibleandtheviewfromthetoporbottomisnotadequatetodiscoverpossible deficienciesordamage.ANationalFireProtectionAssociation(NFPA)211Standard,LevelIIinspectionbya qualifiedprofessional,priortoremovalofpurchasecontingencies,isrecommended.Specializedtools,testing procedures,mirrors,andvideocamerascanbeusedbyaqualifiedfireplaceprofessionaltothoroughlyevaluate thefireplacesystem. fireplace-Safetyhazard.Thedamperisrequiredtobe permanentlyblockedopeninfireplacescontainingagas fixturetopreventgasleaksfromenteringthehome. Installationbyaqualifiedlicensedcontractorisadvised.

A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS Fireplace 1. FireplaceConstruction:Factorybuilt 2.Type:Gaslog 3. SmokeChamber:Metal 4. Flue:MetalNotfullyvisible. 5. Damper:MetalAdamperclampisnotinstalledinthe
6. HearthExtension:Tile AirConditioning A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1stFloorACSystem 1. A/CSystem:Functional 2. CondensateRemoval:PVC 3. CondensingUnit: 4.FuelType:220-240VACTemperatureDifferential:18 5.Type:CentralA/CCapacity: 6. VisibleCoil:Coppercorewithaluminumfins 7. RefrigerantLines:Serviceablecondition SouthwestPropertyInspection Page13of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
AirConditioning(Continued) 8. ElectricalDisconnect:TumbleswitchThedead-frontcover ismissingintheelectricaldisconnectboxattheA/C condensingunit-Shockhazard.Recommendrepairsbya qualifiedlicensedcontractor. 2ndFloorACSystem 9. A/CSystemOperation:FunctionalTheA/Crefrigerantlineiscrimped.Reducedsystemefficiency mayoccur.RepairsbyaqualifiedlicensedHVACcontractorarerecommended. 10. CondensateRemoval:PVC 11.FuelType:220-240VACTemperatureDifferential:17 12.Type:CentralA/CCapacity: 13. VisibleCoil:Aluminum 14. RefrigerantLines:Serviceablecondition SouthwestPropertyInspection Page14of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

AirConditioning(Continued) ElectricalDisconnect:TumbleswitchThedead-frontcover ismissingintheelectricaldisconnectboxattheA/C condensingunit-Shockhazard.Recommendrepairsbya qualifiedlicensedcontractor. BlowerFan/Filters:1stfloorfiltermissing.2ndfloorincorrect size,Thefurnaceairfilterisdirty.Reducedefficiencyand shortenedlife-spanoftheunitmayoccur.Recommend replacementofthefilters.

15.
16. ExposedDuctwork:Insulatedflex 17.
18. Thermostats:Programmable HeatingSystem Note:Thefurnacesarelocatedintheattic. A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1stFloorHeatingSystem SouthwestPropertyInspection Page15of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
HeatingSystem(Continued) 1. HeatingSystem:InadequateTheheatingsystemis inoperative.RepairsbyaqualifiedlicensedHVACcontractor arerecommended. 2.Manufacturer:York 3.Type:ForcedairunitCapacity: 4.FuelType:Naturalgas 5. HeatExchanger: 6. BlowerFan/Filters: 7. Distribution:Insulatedflex 8. VentPipe:B-vent 9. Controls: 2ndFloorHeatingSystem 10. HeatingSystemOperation:Functional 11.Manufacturer:York 12.AreaServed:2ndflooronlyApproximateAge: 13.FuelType:Naturalgas 14. HeatExchanger: 15. Distribution:Fiberglassducts 16. FluePipe:B-vent 17. Thermostats:Programmable SouthwestPropertyInspection Page16of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Bathrooms A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1stFloorHallwayBathroom 1. Ceiling: 2. Walls: 3. Floor:Stone 4. Doors: 5. Electrical:110VACGFCIoutlets,Lighting 6. CounterTop:Laminateandcomposite 7. Cabinets:Wood 8. Sinks:Pedestal 9. Plumbing/Fixtures:Thesinkfaucetfixtureisloose.Leakagemayoccur.Repairsbyaqualified licensedplumberarerecommended. 10. Shower:Acrylicpanandsurround 11. Toilet: 12. HVACSource: 13. Ventilation:Exhaustfan 2ndFloorGuestBathroom 14. Ceiling: 15. Walls: 16. Floor:Vinyl 17. Doors: 18. Electrical:110VACGFCIoutlets,Lighting 19. CounterTop:Tile 20. Cabinets:Wood 21. Sinks:Porcelainsingle-bowl 22. Plumbing/Fixtures: 23. Tub: 24. Shower: SouthwestPropertyInspection Page17of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Bathrooms(Continued) 25. Toilet:Thetoiletdoesnotflushproperly.Theflushassemblyrequiresrepairoradjustment.Repairs byaqualifiedlicensedplumberarerecommended. 26. HVACSource: 27. Ventilation:Exhaustfan MasterBathroom 28. Ceiling: 29. Walls: 30. Floor:Carpet 31. Doors: 32. Windows:Thewindowlatchbythetoiletisdamaged. Repairsbyaqualifiedwindowcontractorarerecommended. 33. Electrical:110VACGFCIoutlets,Lighting 34. CounterTop: 35. Cabinets:Wood 36. Sinks:Porcelain-Dualbasin 37. Plumbing/Fixtures: SouthwestPropertyInspection Page18of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Bathrooms(Continued) 38. Tub:Thecaulkingaroundthetopoftubisdeteriorated. Moisturepenetrationmayoccur.Repairsbyaqualified licensedcontractorarerecommended. 39. Shower:Acrylicpanandceramictilesurround 40. Toilet: 41. HVACSource: 42. Ventilation:Window Bedrooms A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS Bedroom 1. Closets: 2. Ceilings:Drywall 3. Walls:Drywall 4. Floors:Hardwood 5. Doors:Thedoorhardwareislooseinthe2ndfloorguest bedroom,Repairsbyaqualifiedlicensedcontractorare recommended. SouthwestPropertyInspection Page19of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Bedrooms(Continued) 6. Windows:Thewindowglassiscrackedinthe2ndfloorfront guestbedroom.Repairsbyaqualifiedwindowcontractorare recommended. 7. Electrical:110VACoutlets,Lighting 8. HVACSource: LivingSpace A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS LivingSpace 1. Closets: 2. Ceilings:Drywall 3. Walls:Drywall 4. Floors:Stone 5. Doors: 6. Windows:Vinylwithdual-paneglass 7. Electrical:110VACoutlets,Lighting 8. HVACSource: Kitchen A=Acceptable,NI=NotInspected,M=Maintenance,HS=Health&Safety ANIMHS 1stFloorKitchen SouthwestPropertyInspection Page20of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.
Kitchen(Continued) 1. CookingAppliances:GeneralElectric 2. Ventilator:Aductfortheovenexhaustfanisnotinstalled.Theexhaustairblowsintotheupper cabinet.Repairsbyacertifiedappliancetechnicianarerecommended. 3. Disposal: 4. Dishwasher:Amana SouthwestPropertyInspection Page21of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

5.AirGapPresent? NoWaterflowsoutoftheairgapandonto thecountertopwhenthedishwasherdrains.Theknock-outatthefood wastedisposalmaynotberemoved.Waterdamagemayoccur. Repairsbyaqualifiedlicensedplumberarerecommended. countertopback-splash.Waterentrymayoccur.Re-grouting byaqualifiedlicensedcontractorisrecommended.

Kitchen(Continued)
Yes
6. Sink:Stainlesssteel-Dualbasin 7. Electrical:110VACGFCIoutlets,Lighting 8. Plumbing/Fixtures: 9. CounterTop:TileThegroutingiscrackedatthe
10. Cabinets:Wood 11. Ceiling:Drywall 12. Walls: 13. Floor:Stone 14. Windows:Vinylwithdual-paneglass 15. HVACSource: SouthwestPropertyInspection Page22of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

STANDARDRESIDENTIALINSPECTIONAGREEMENT

THISISINTENDEDTOBEALEGALLYBINDINGCONTRACT,PLEASEREADITCAREFULLY.

SCOPEOFTHEINSPECTION:TherealestateinspectiontobeperformedfortheClientisasurveyandbasic operationofthesystemsandcomponentsofabuildingwhichcanbereached,entered,orviewedwithoutdifficulty, movingobstructions,orrequiringanyactionwhichmayresultindamagetothepropertyorpersonalinjurytothe Inspector.ThepurposeoftheinspectionistoprovidetheClientwithinformationregardingthegeneralconditionof thebuilding(s).InspectorwillprepareandprovideClientawrittenreportforthesoleuseandbenefitofClient.The writtenreportshalldocumentanymaterialdefectsdiscoveredinthebuilding'ssystemsandcomponentswhich,in theopinionoftheInspector,aresafetyhazards,arenotfunctioningproperly,orappeartobeattheendsoftheir servicelives.TheinspectionshallbeperformedinaccordancewiththeStandardsofPracticeoftheCaliforniaReal EstateInspectionAssociation(CREIA),attachedheretoandincorporatedhereinbyreference,andislimitedto thoseitemsspecifiedherein.

CLIENT'SDUTY:ClientagreestoreadtheentirewrittenreportwhenitisreceivedandpromptlycallInspectorwith anyquestionsorconcernsregardingtheinspectionorthewrittenreport.Thewrittenreportshallbethefinaland exclusivefindingsofInspector.ClientacknowledgesthatInspectorisageneralistandthatfurtherinvestigationofa reportedconditionbyanappropriatespecialistmayprovideadditionalinformationwhichcanaffectClient's purchasedecision.Clientagreestoobtainfurtherevaluationofreportedconditionsbeforeremovingany investigationcontingencyandpriortothecloseofthetransaction.IntheeventClientbecomesawareofa reportableconditionwhichwasnotreportedbyInspector,ClientagreestopromptlynotifyInspectorandallow InspectorandlorInspector'sdesignatedrepresentative(s)toinspectsaidcondition(s)priortomakinganyrepair, alteration,orreplacement.ClientagreesthatanyfailuretosonotifyInspectorandallowinspectionisamaterial breachofthisAgreement.

ENVIRONMENTALCONDITIONS:Clientagreeswhatisbeingcontractedforisabuildinginspectionandnotan environmentalevaluation.Theinspectionisnotintendedtodetectidentify,ordiscloseanyhealthorenvironmental conditionsregardingthisbuildingorproperty,including,butnotlimitedto:thepresenceofasbestos,radon,lead, urea-formaldehyde,fungi,molds,mildew,PCBs,orothertoxic,reactive,combustible,orcorrosivecontaminants, materials,orsubstancesinthewater,air,soil,orbuildingmaterials.TheInspectorisnotliableforinjury,health risks,ordamagecausedorcontributedtobytheseconditions.

GENERALPROVISIONS:Thewrittenreportisnotasubstituteforanytransferor'soragent'sdisclosurethatmay berequiredbylaw,orasubstituteforClient'sindependentdutytoreasonablyevaluatethepropertypriortothe closeofthetransaction.ThisinspectionAgreement,therealestateinspection,andthewrittenreportdonot

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

InspectionAgreement PropertyInformation ClientInformation InspectionCompany InspectorNameSteveLindsey CompanyNameSouthwestPropertyInspection Conditions
SouthwestPropertyInspection Page23of35

InspectionAgreement(Continued)

constituteahomewarranty,guarantee,orinsurancepolicyofanykindwhatsoever.Nolegalactionorproceeding ofanykind,includingthosesoundingintortorcontract,canbecommencedagainstlnspector/lnspectionCompany oritsofficers,agents,oremployeesmorethanoneyearfromthedateClientdiscovers,orthroughtheexerciseof reasonablediligenceshouldhavediscovered,thecauseofaction.Innoeventshallthetimeforcommencementof alegalactionorproceedingexceedtwoyearsfromthedateofthesubjectinspection.THISTIMEPERIODIS SHORTERTHANOTHERWISEPROVIDEDBYLAW.

ThisAgreementshallbebindinguponandinuretothebenefitofthepartiesheretoandtheirheirs,successors,and assigns.

ThisAgreementconstitutestheentireintegratedagreementbetweenthepartiesheretopertainingtothesubject matterhereofandmaybemodifiedonlybyawrittenagreementsignedbyallofthepartieshereto.Nooral agreements,understandings,orrepresentationsshallchange,modify,oramendanypartofthisAgreement.

EachpartysigningthisAgreementwarrantsandrepresentsthathelshehasthefullcapacityandauthorityto executethisAgreementonbehalfofthenamedparty.IfthisAgreementisexecutedonbehalfofClientbyanythird party,thepersonexecutingthisAgreementexpresslyrepresentstoInspectorthathelshehasthefullandcomplete authoritytoexecutethisAgreementonClient'sbehalfandtofullyandcompletelybindClienttoalloftheterms, conditions,limitations,exceptions,andexclusionsofthisAgreement.

SEVERABILITY:ShouldanyprovisionofthisAgreementbeheldbyacourtofcompetentjurisdictiontobeeither invalidorunenforceable,theremainingprovisionsofthisAgreementshallremaininfullforceandeffect, unimpairedbythe court'sholding.

MEDIATION:ThepartiestothisAgreementagreetoattend,ingoodfaith,mediationwitharetiredjudgeorlawyer withatleast5yearsofmediationexperiencebeforeanylawsuitisfiled.Allnoticesofmediationmustbeservedin writingbyreturnreceiptrequestedallowing30daysforresponse.Ifnoresponseisforthcomingthemovingparty maythendemandbindingarbitrationunderthetermsandprovisionssetforthbelow.

ARBITRATION:AnydisputeconcerningtheinterpretationorenforcementofthisAgreement,theinspection,the inspectionreportoranyotherdisputearisingoutofthisrelationship,shallberesolvedbetweenthepartiesby bindingarbitrationconductedinaccordancewithCaliforniaLaw,exceptthatthepartiesshallselectanarbitrator whoisfamiliarwiththerealestateprofession.Thepartiesagreethattheyshallbeentitledtodiscoveryprocedures withinthediscretionofthearbitrator.ThearbitratorshallmanageandhearthecaseapplyingthelawsoftheState ofCaliforniatoallissuessubmittedinthearbitrationproceeding.Theawardofthearbitratorshallbefinal,anda judgmentmaybeenteredonitbyanycourthavingjurisdiction.Anydisputesaretobearbitratedby:Construction ArbitrationServices,Inc.

RESIDENTIALSTANDARDSOFPRACTICE-FOURORFEWERUNITS

PartI.DefinitionsandScope

TheseStandardsofPracticeprovideguidelinesforarealestateinspectionanddefinecertaintermsrelatingto theseinspections.ItalicizedwordsintheseStandardsaredefinedinPartIV,GlossaryofTerms.

A.Arealestateinspectionisasurveyandbasicoperationofthesystemsandcomponentsofabuildingwhichcan

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

SouthwestPropertyInspection Page24of35

InspectionAgreement(Continued)

bereached,entered,orviewedwithoutdifficulty,movingobstructions,orrequiringanyactionwhichmayresultin damagetothepropertyorpersonalinjurytotheInspector.ThepurposeoftheinspectionistoprovidetheClient withinformationregardingthegeneralconditionofthebuilding(s).Cosmeticandaestheticconditionsshallnotbe considered.

B.Arealestateinspectionreportprovideswrittendocumentationofmaterialdefectsdiscoveredintheinspected building'ssystemsandcomponentswhich,intheopinionoftheInspector,aresafetyhazards,arenotfunctioning properly,orappeartobeattheendsoftheirservicelives.ThereportmayincludetheInspector's recommendationsforcorrectionorfurtherevaluation.

C.InspectionsperformedinaccordancewiththeseStandardsofPracticearenottechnicallyexhaustiveandshall applytotheprimarybuildinganditsassociatedprimaryparkingstructure.

PartII.StandardsofPractice

Arealestateinspectionincludesthereadilyaccessiblesystemsandcomponentsorarepresentativenumberof multiplesimilarcomponentslistedinSECTIONS1through9subjecttothelimitations,exceptions,andexclusions inPartIII.

SECTION1-Foundation,Basement,andUnder-floorAreas

A.Itemstobeinspected:

B.TheInspectorisnotrequiredto:

1.Determinesize,spacing,location,oradequacyoffoundationbolting/bracingcomponentsorreinforcingsystems

SECTION2-Exterior

A.Itemstobeinspected: 1.Surfacegradedirectlyadjacenttothebuildings

3.Attacheddecks,porches,patios,balconies,stairways,andtheirenclosures

B.TheInspectorisnotrequiredto:

1.Inspectdoororwindowscreens,shutters,awnings,orsecuritybars

2.Inspectfencesorgatesoroperateautomateddoororgateopenersortheirsafetydevices

SECTION3-RoofCovering

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

1.Foundationsystem 2.Floorframingsystem 3.Under-floorventilation 4.Foundationanchoringandcripplewallbracing 5.Woodseparationfromsoil 6.Insulation
2.Determinethecompositionorenergyratingofinsulationmaterials
2.Doorsandwindows
4.Wallcladdingandtrim 5.Portionsofwalkwaysanddrivewaysthatareadjacenttothebuildings
3.Usealaddertoinspectsystemsorcomponents
SouthwestPropertyInspection Page25of35

InspectionAgreement(Continued)

A.Itemstobeinspected:

1.Covering

B.TheInspectorisnotrequiredto:

1.WalkontheroofsurfaceifintheopinionoftheInspectorthereisriskofdamageorahazardtotheInspector

2.Warrantorcertifythatroofsystems,coverings,orcomponentsarefreefromleakage

SECTION4-AtticAreasandRoofFraming

A.Itemstobeinspected:

1.Framing

B.TheInspectorisnotrequiredto:

1.Inspectmechanicalatticventilationsystemsorcomponents

2.Determinethecompositionorenergyratingofinsulationmaterials

SECTION5-Plumbing

A.Itemstobeinspected:

B.TheInspectorisnotrequiredto:

1.Fillanyfixturewithwaterorinspectoverflowdrainsordrain-stops,orevaluatebackflowdevices,wasteejectors, sumppumps,ordrainlinecleanouts

2.Inspectorevaluatewatertemperaturebalancingdevices,temperaturefluctuation,timetoobtainhotwater,water circulation,orsolarheatingsystemsorcomponents

3.Inspectwhirlpoolbaths,steamshowers,orsaunasystemsorcomponents

4.Inspectfueltanksordetermineifthefuelgassystemisfreeofleaks

5.Inspectwellsorwatertreatmentsystems

SECTION6-Electrical

A.Itemstobeinspected:

1.Serviceequipment

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

2.Drainage 3.Flashings 4.Penetrations 5.Skylights
2.Ventilation 3.Insulation
1.Watersupplypiping 2.Drain,waste,andventpiping 3.Faucetsandfixtures 4.Fuelgaspiping 5.Waterheaters 6.Functionalflowandfunctionaldrainage
2.Electricalpanels 3.Circuitwiring 4.Switches,receptacles,outlets,andlightingfixtures SouthwestPropertyInspection Page26of35

InspectionAgreement(Continued)

B.TheInspectorisnotrequiredto:

1.Operatecircuitbreakersorcircuitinterrupters

3.Inspectde-icingsystemsorcomponents

4.Inspectprivateoremergencyelectricalsupplysystemsorcomponents

SECTION7-HeatingandCooling

A.Itemstobeinspected:

B.TheInspectorisnotrequiredto:

1.Inspectheatexchangersorelectricheatingelements

2.Inspectnon-centralairconditioningunitsorevaporativecoolers

3.Inspectradiantsolar,hydronic,orgeothermalsystemsorcomponents

4.Determinevolume,uniformity,temperature,airflow,balance,orleakageofanyairdistributionsystem

SECTION8-FireplacesandChimneys

A.Itemstobeinspected:

B.TheInspectorisnotrequiredto: 1.Inspectchimneyinteriors

3.Operateanyfireplaceordetermineifafireplacecanbesafelyused

SECTION9-BuildingInterior

A.Itemstobeinspected:

1.Walls,ceilings,andfloors

3.Stairways,handrails,andguardrails

4.Permanentlyinstalledcabinets

5.Permanentlyinstalledcook-tops,mechanicalrangevents,ovens,dishwashers,andfoodwastedisposers

7.Vehicledoorsandopeners

B.TheInspectorisnotrequiredto:

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

2.Removecoverplates
1.Heatingequipment 2.Centralcoolingequipment 3.Energysourceandconnections 4.Combustionairandexhaustventsystems 5.Condensatedrainage 6.Conditionedairdistributionsystems
5.Inspectelectronicairfilteringorhumiditycontrolsystemsorcomponents
1.Chimneyexterior 2.Sparkarrestor 3.Firebox 4.Damper 5.Hearthextension
2.Inspectfireplaceinserts,seals,orgaskets
2.Doorsandwindows
6.Absenceofsmokealarms
SouthwestPropertyInspection Page27of35

InspectionAgreement(Continued)

1.Inspectwindow,door,orfloorcoverings

2.Determinewhetherabuildingissecurefromunauthorizedentry

3.Operateortestsmokealarmsorvehicledoorsafetydevices

4.Usealaddertoinspectsystemsorcomponents

PartIII.Limitations,Exceptions,andExclusions

A.Thefollowingareexcludedfromarealestateinspection:

1.Systemsorcomponentsofabuilding,orportionsthereof,whicharenotreadilyaccessible,notpermanently installed,ornotinspectedduetocircumstancesbeyondthecontroloftheInspectororwhichtheClienthasagreed orspecifiedarenottobeinspected

2.Siteimprovementsoramenities,including,butnotlimitedto;accessorybuildings,fences,planters,landscaping, irrigation,swimmingpools,spas,ponds,waterfalls,fountainsortheircomponentsoraccessories

3.Auxiliaryfeaturesofappliancesbeyondtheappliance'sbasicfunction

4.Systemsorcomponents,orportionsthereof,whichareunderground,underwater,orwheretheInspectormust comeintocontactwithwater

5.CommonareasasdefinedinCaliforniaCivilCodesection1351,etseq.,andanydwellingunitsystemsor componentslocatedincommonareas

6.Determiningcompliancewithmanufacturers'installationguidelinesorspecifications,buildingcodes,accessibility standards,conservationorenergystandards,regulations,ordinances,covenants,orotherrestrictions

7.Determiningadequacy,efficiency,suitability,quality,age,orremaininglifeofanybuilding,system,or component,ormarketabilityoradvisabilityofpurchase

8.Structural,architectural,geological,environmental,hydrological,landsurveying,orsoils-relatedexaminations

9.Acousticalorothernuisancecharacteristicsofanysystemorcomponentofabuilding,complex,adjoining property,orneighborhood

10.Conditionsrelatedtoanimals,insects,orotherorganisms,includingfungusandmold,andanyhazardous, illegal,orcontrolledsubstance,orthedamageorhealthrisksarisingtherefrom

11.Risksassociatedwitheventsorconditionsofnatureincluding,butnotlimitedto;geological,seismic,wildfire, andflood

12.Watertestinganybuilding,system,orcomponentordetermineleakageinshowerpans,pools,spas,orany bodyofwater

13.Determiningtheintegrityofhermeticsealsatmulti-paneglazing

14.Differentiatingbetweenoriginalconstructionorsubsequentadditionsormodifications

15.Reviewinginformationfromanythird-party,includingbutnotlimitedto;productdefects,recalls,orsimilar notices

16.Specifyingrepairs/replacementproceduresorestimatingcosttocorrect

17.Communication,computer,security,orlow-voltagesystemsandremote,timer,sensor,orsimilarlycontrolled systemsorcomponents

18.Fireextinguishingandsuppressionsystemsandcomponentsordeterminingfireresistivequalitiesofmaterials orassemblies

19.Elevators,lifts,anddumbwaiters

20.Lightingpilotlightsoractivatingoroperatinganysystem,component,orappliancethatisshutdown,unsafeto operate,ordoesnotrespondtonormalusercontrols

21.Operatingshutoffvalvesorshuttingdownanysystemorcomponent

22.Dismantlinganysystem,structure,orcomponentorremovingaccesspanelsotherthanthoseprovidedfor homeownermaintenance

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

SouthwestPropertyInspection Page28of35

InspectionAgreement(Continued)

B.TheInspectormay,athisorherdiscretion:

1.Inspectanybuilding,system,component,appliance,orimprovementnotincludedorotherwiseexcludedby theseStandardsofPractice.AnysuchinspectionshallcomplywithallotherprovisionsoftheseStandards.

2.IncludephotographsinthewrittenreportortakephotographsforInspector'sreferencewithoutinclusioninthe writtenreport.Photographsmaynotbeusedinlieuofwrittendocumentation.

PartIV.GlossaryofTerms

*NOTE:Alldefinitionsapplytoderivativesofthesetermswhenitalicizedinthetext.

Appliance:Anitemsuchasanoven,dishwasher,heater,etc.whichperformsaspecificfunction Building:Thesubjectoftheinspectionanditsprimaryparkingstructure

Component:Apartofasystem,appliance,fixture,ordevice Condition:Conspicuousstateofbeing

Determine:Arriveatanopinionorconclusionpursuanttoarealestateinspection

Device:Acomponentdesignedtoperformaparticulartaskorfunction

Fixture:Aplumbingorelectricalcomponentwithafixedpositionandfunction

Function:Thenormalandcharacteristicpurposeoractionofasystem,component,ordevice

FunctionalDrainage:Theabilitytoemptyaplumbingfixtureinareasonabletime

FunctionalFlow:Theflowofthewatersupplyatthehighestandfarthestfixturefromthebuildingsupplyshutoff valvewhenanotherfixtureisusedsimultaneously

Inspect:RefertoPartI,"DefinitionandScope",ParagraphA

Inspector:Onewhoperformsarealestateinspection

NormalUserControl:Switchorotherdevicethatactivatesasystemorcomponentandisprovidedforusebyan occupantofabuilding

Operate:Causeasystem,appliance,fixture,ordevicetofunctionusingnormalusercontrols

PermanentlyInstalled:Fixedinplace,e.g.screwed,bolted,nailed,orglued

PrimaryBuilding:AbuildingthatanInspectorhasagreedtoinspect

PrimaryParkingStructure:Abuildingforthepurposeofvehiclestorageassociatedwiththeprimarybuilding

ReadilyAccessible:Canbereached,entered,orviewedwithoutdifficulty,movingobstructions,orrequiringany actionwhichmayharmpersonsorproperty

RealEstateInspection:RefertoPartI,"DefinitionsandScope",ParagraphA

RepresentativeNumber:Example,anaverageofonecomponentperareaformultiplesimilarcomponentssuchas windows,doors,andelectricaloutlets

SafetyHazard:Aconditionthatcouldresultinsignificantphysicalinjury

ShutDown:Disconnectedorturnedoffinawaysoasnottorespondtonormalusercontrols

System:Anassemblageofvariouscomponentsdesignedtofunctionasawhole

TechnicallyExhaustive:Examinationbeyondthescopeofarealestateinspection,whichmayrequiredisassembly, specializedknowledge,specialequipment,measuring,calculating,quantifying,testing,exploratoryprobing, research,oranalysis

NOTE:SouthwestPropertyInspectionshasaffiliationswiththird-partyserviceproviders(TPSP)inordertooffer value-addedservicestoourClients.ThecompanymayarrangefortheseTPSPstosendliteratureormake post-inspectioncontactwithourclients.

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

SouthwestPropertyInspection Page29of35
InspectionAgreement(Continued) ESCROWBILLING:Anadditionalfeeof$100.00willbeincurredforthoseclientsbillingthroughescrow.Ifescrow iscancelledforanyreason,yourcreditcardwillbebilledfortheentireinspectionfee. REPORTDELIVERY:Theinspectionreportwillbedeliveredtoallrealestateagentsinvolvedinthetransaction unlessyourequestusnotto. SouthwestPropertyInspection Page30of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

REGARDINGREPAIRS:Itisrecommendedthatanydeficienciesandthecomponents/systemsrelatedto thesedeficienciesnotedinthereportbeevaluated/inspectedandrepairedasneededbylicensed contractors/professionalsPRIORTOTHECLOSEOFESCROW.FurtherevaluationPRIORtothecloseof escrowisrecommendedsoaproperlylicensedprofessionalcanfurtherevaluateourconcernsandinspect theremainderofthesystemorcomponentforadditionalconcernsthatmaybeoutsideourareaofexpertise orthescopeofthisinspection.

PHOTOS:Thephotosshowninthisreportarerepresentative.Theremaynotbephotosofalldeficientitems present.Aqualifiedlicensedprofessionalshouldbeconsultedtodeterminethefullextentofrepairs necessaryforeachdeficientitemnoted.

WATER/MOISTURE:Waterleaks,waterintrusion,andmoisturecancausemoldandmildew.Ifsuch conditionswerenotedinthisreport,furtherinvestigationbyacertifiedmicrobialconsultantoralicensed industrialhygienistisrecommended.

NOTICETOTHIRDPARTIES:ThisinspectionreportisforthesolebenefitandrelianceoftheClientnamed intheoriginalreportandisnottransferabletoanythirdparty.Thereportoftheinspectionandall consultationbetweentheInspectorandtheClientisissuedsubjecttotheterms,conditions,andlimitations underwhichtheinspectionwasperformed.Theterms,conditions,andlimitationsareapartofthisreport andareattachedheretoandincorporatedhereinbyreference.TheInspectorassumesnoliabilityforthird partyintervention,reliance,oruseofthisreportpreparedfortheClientnamedherein.THIRDPARTIES AREENCOURAGEDTOOBTAINAHOMEINSPECTIONFROMAQUALIFIEDINSPECTOROFTHEIR CHOICE.ANYTHIRDPARTY,INCLUDINGOTHERPURCHASERSWHOARENOTPARTOFTHIS CONTRACT,MAYNOTRELYON,ORUSE,THISREPORTFORANYPURPOSEANDSHOULDNOT MAKEANYDECISIONSBASEDONTHISREPORT.THEINSPECTORASSUMESNOLIABILITYFOR THIRDPARTYINTERPRETATIONORUSEOFTHISREPORT.

HAZARDOUSMATERIALWARNING:Lead,asbestos,radon,andotherenvironmentalhazards,materials, orconditionsarebeyondthescopeofthispropertyinspectionandarespecificallyexcluded.Asbestoswas widelyusedinbuildingmaterialspriorto1978,withlimitedusethereafter.Paintmanufacturedpriorto1978 commonlycontainedlead.Yourrealestateagentmaybeabletoprovideyouwithinformationregarding these,andother,hazardousmaterialsthatmaybepresent.Anenvironmentalsurveymaybeobtainedby contractingwithanappropriatespecialist.

CHINESEDRYWALL:TheInspectorisnotqualifiedtodetectthepresenceofChinesedrywall.Accordingly, theissueofChinesedrywall(anditspotentialproblems)isbeyondthescopeofthisinspection.

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

FinalComments
SouthwestPropertyInspection Page31of35

MaintenanceSummary

IMPORTANTNOTE-PLEASEREAD:Thissummaryprovidesabriefoverviewofthereport.Itisnotall-encompassing.Readingthis summaryisnotasubstituteforreadingthereportinitsentirety.Theentireinspectionreportmustbereadtofullyassessthefindingsof theinspection.Thislistisnotintendedtodeterminewhichitemsmayneedtobeaddressedperthecontractualrequirementsofthe saleoftheproperty.Anyareasofuncertaintyregardingthecontractshouldbeclarifiedbyconsultinganattorneyorrealestateagent.

Itisrecommendedthatanydeficienciesandthecomponents/systemsrelatedtothesedeficienciesnotedinthereportbe evaluated/inspectedandrepairedasneededbylicensedcontractors/professionalsPRIORTOTHECLOSEOFESCROW.Further evaluationPRIORtothecloseofescrowisrecommendedsoaproperlylicensedprofessionalcanfurtherevaluateourconcernsand inspecttheremainderofthesystemorcomponentforadditionalconcernsthatmaybeoutsideourareaofexpertiseorthescopeof thisinspection.

ExteriorSurfaceandComponents

1.DoorBell:Thedoorbellisinoperative.Repairsbyaqualifiedlicensedcontractorarerecommended.

2.PatioDoors:Vinylsliderwithdual-paneglassThepatioscreendoorsaremissing.Recommendreplacement. Repairsbyaqualifiedlicensedcontractorarerecommended.

3.Windows:Moistureandfoggingwerenotedinthedual-paneglassofthewindowsinthefollowinglocations: 2ndfloormaster,2ndfloorguestbedroomandoveropenareaabove(Defectivehermeticseals.)Repairsbya qualifiedlicensedwindowcontractorarerecommended.

Note:Duetoclimaticconditions,thenatureofthecomponents,andthecleanlinessoftheglass,itisnot possibletodetermineallofthefailurespresent.Evaluationoftheremainingwindowsinthehomebyaqualified licensedglazingcontractorisrecommendedpriortoremovalofpurchasecontingencies.

4.ExteriorLighting:Loosewiringandbulbassemblysideofgarage.Repairsbyaqualifiedlicensedelectricianare recommended.

Garage

5.GarageElectrical:110VACGFCIoutlets,LightingWiringforfrontlightsrunoffoflightswitch,recommend addseparatejunctionbox,Evaluationbyaqualifiedlicensedelectricianisrecommended.

Plumbing

6.WaterPressure:100PSIThewaterpressureisexcessive.Excessivewaterpressurecancausedamageand leaksattheplumbingcomponents.Recommendhavingaqualifiedlicensedplumberreducethewaterpressure to40-80PSI.

LaundryRoom/Area

7.1stFloorLaundryRoom/AreaWasherHoseBib:Thehotandcoldwatervalvesareleaking.Repairsbya qualifiedlicensedplumberarerecommended.

AirConditioning

8.2ndFloorACSystemA/CSystemOperation:FunctionalTheA/Crefrigerantlineiscrimped.Reducedsystem efficiencymayoccur.RepairsbyaqualifiedlicensedHVACcontractorarerecommended.

9.BlowerFan/Filters:1stfloorfiltermissing.2ndfloorincorrectsize,Thefurnaceairfilterisdirty.Reduced efficiencyandshortenedlife-spanoftheunitmayoccur.Recommendreplacementofthefilters.

HeatingSystem

10.1stFloorHeatingSystemHeatingSystem:InadequateTheheatingsystemisinoperative.Repairsbya qualifiedlicensedHVACcontractorarerecommended.

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

SouthwestPropertyInspection Page32of35

MaintenanceSummary(Continued)

Bathrooms

11.1stFloorHallwayBathroomPlumbing/Fixtures:Thesinkfaucetfixtureisloose.Leakagemayoccur.Repairs byaqualifiedlicensedplumberarerecommended.

12.2ndFloorGuestBathroomToilet:Thetoiletdoesnotflushproperly.Theflushassemblyrequiresrepairor adjustment.Repairsbyaqualifiedlicensedplumberarerecommended.

13.MasterBathroomWindows:Thewindowlatchbythetoiletisdamaged.Repairsbyaqualifiedwindow contractorarerecommended.

14.MasterBathroomTub:Thecaulkingaroundthetopoftubisdeteriorated.Moisturepenetrationmayoccur. Repairsbyaqualifiedlicensedcontractorarerecommended.

Bedrooms

15.BedroomDoors:Thedoorhardwareislooseinthe2ndfloorguestbedroom,Repairsbyaqualifiedlicensed contractorarerecommended.

16.BedroomWindows:Thewindowglassiscrackedinthe2ndfloorfrontguestbedroom.Repairsbyaqualified windowcontractorarerecommended.

Kitchen

17.1stFloorKitchenVentilator:Aductfortheovenexhaustfanisnotinstalled.Theexhaustairblowsintothe uppercabinet.Repairsbyacertifiedappliancetechnicianarerecommended.

18.1stFloorKitchenAirGapPresent?YesWaterflowsoutoftheairgapandontothecountertopwhenthe dishwasherdrains.Theknock-outatthefoodwastedisposalmaynotberemoved.Waterdamagemayoccur. Repairsbyaqualifiedlicensedplumberarerecommended.

19.1stFloorKitchenCounterTop:TileThegroutingiscrackedatthecountertopback-splash.Waterentrymay occur.Re-groutingbyaqualifiedlicensedcontractorisrecommended.

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

SouthwestPropertyInspection Page33of35

Health&SafetySummary

IMPORTANTNOTE-PLEASEREAD:Thissummaryprovidesabriefoverviewofthereport.Itisnotall-encompassing.Readingthis summaryisnotasubstituteforreadingthereportinitsentirety.Theentireinspectionreportmustbereadtofullyassesthefindingsof theinspection.Thislistisnotintendedtodeterminewhichitemsmayneedtobeaddressedperthecontractualrequirementsofthe saleoftheproperty.Anyareasofuncertaintyregardingthecontractshouldbeclarifiedbyconsultinganattorneyorrealestateagent.

Itisrecommendedthatanydeficienciesandthecomponents/systemsrelatedtothesedeficienciesnotedinthereportbe evaluated/inspectedandrepairedasneededbylicensedcontractors/professionalsPRIORTOTHECLOSEOFESCROW.Further evaluationPRIORtothecloseofescrowisrecommendedsoaproperlylicensedprofessionalcanfurtherevaluateourconcernsand inspecttheremainderofthesystemorcomponentforadditionalconcernsthatmaybeoutsideourareaofexpertiseorthescopeof thisinspection.

Garage

1.GarageDoorOpener:LiftMasterThepressuresensorsafetyreversingsystemonthegaragedooropener requiresadjustment.Thedoordoesnotreversewhenanobjectblocksitspath-Safetyhazard.Repairsbya qualifiedlicensedgaragedoorcontractorarerecommended.

2.GarageFireDoor:Fire-rated,Self-closingClosingmechanisminoperativeonthegaragefiredoor(leading intothehouse)causingabreachinthefire-resistant-ratedassemblybetweenthegarageandthehouse-Fire hazard.Repairsbyaqualifiedlicensedcontractorarerecommended.

3.GarageCeiling:DrywallThereareunrepairedholesinthegarageceilingcausingabreachinthe fire-resistant-ratedassemblybetweenthegarageandthehouse-Firehazard.Thereisanunrepairedholein thegarageceilingcausingabreachinthefire-resistant-ratedassemblybetweenthegarageandthehouseFirehazard.

Plumbing

4.GarageWaterHeaterTPRValve/DischargeLine:TheTPRvalvedoesnothaveadischargelineinstalledSafetyhazard.Repairsbyaqualifiedlicensedplumberarerecommended.

Electrical

5.CarbonMonoxideDetectors:Thereisnotacarbonmonoxidedetectorinstalledinthehome.(Requiredoutside ofthesleepingareasintheimmediatevicinityofthebedrooms,andoneachlevelofthehome.)Safetyhazard totheoccupants.Installationisadvisedinaccordancewithcurrentapplicablestateandlocalregulations,andin theinterestofoccupantsafety.

6.ElectricPanelManufacturer:Cutler-HammerThehingesarelooseontheelectricpanelcover.Thecoverfalls off.Waterentrymayoccur.Fire/Shockhazard.Repairsbyaqualifiedlicensedelectricianarerecommended.

Fireplace

7.FireplaceDamper:MetalAdamperclampisnotinstalledinthefireplace-Safetyhazard.Thedamperis requiredtobepermanentlyblockedopeninfireplacescontainingagasfixturetopreventgasleaksfrom enteringthehome.Installationbyaqualifiedlicensedcontractorisadvised.

AirConditioning

8.1stFloorACSystemElectricalDisconnect:TumbleswitchThedead-frontcoverismissingintheelectrical disconnectboxattheA/Ccondensingunit-Shockhazard.Recommendrepairsbyaqualifiedlicensed contractor.

9.2ndFloorACSystemElectricalDisconnect:TumbleswitchThedead-frontcoverismissingintheelectrical disconnectboxattheA/Ccondensingunit-Shockhazard.Recommendrepairsbyaqualifiedlicensed contractor.

Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.

SouthwestPropertyInspection Page34of35

Health&SafetySummary(Continued)

SouthwestPropertyInspection Page35of35 Palm-TechInspector,Copyright©1998-2018,PDmB,Inc.