Alarm Troubleshooting Flowcharts

Page 1


Troubleshooting/Ice Machine Alarms

ICE MACHINE ALARM

NO POWER TO UNIT

ICE MACHINE ERROR SHUTDOWN MAX/SLOW WATER FILL TIME

ICE MACHINE ERROR SHUTDOWN MAX FREEZE TIME

ICE MACHINE ERROR SHUTDOWN MINIMUM/SHORT FREEZE TIME

LIKELY CAUSE OF ALARM PROBABLE SOLUTION

POWER DISCONNECTED

LOSS OF WATER PRESSURE

WATER LEAK

AIR FILTER/CONDENSER CLOGGED

ICE THICKNESS SENSOR

WATER DISTRIBUTOR

INLET WATER VALVE LEAKS

INCOMPLETE HARVEST

HIGH PRESSURE CUT OUT OPEN

FAN PRESSURE CONTROL OPEN

WATER PUMP NOT PUMPING

PUMP HOSE DISCONNECTED

COMPRESSOR NOT OPERATING

LOW REFRIGERANT CHARGE

HOT GAS VALVE

THERMOSTATIC EXPANSION VALVE

COMPRESSOR INEFFICIENT

GROUNDED ICE THICKNESS SENSOR

WATER DISTRIBUTOR/SPILLWAY SURFACE

BRIDGE THICKNESS

RESET BREAKER

TURN WATER ON REPLACE CLOGGED FILTER CHECK DEMAND PUMP (RO)

CHECK PURGE VALVE, CURTAIN, SUMP, PUMP HOSE

CLEAN AIR FILTERS/CONDENSER

CHECK/CLEAN ICE THICKNESS SENSOR

REMOVE AND CLEAN WATER DISTRIBUTOR

CHECK WATER INLET VALVE

CONTACT SCOTSMAN TECHNICIAN

CHECK GAP, CLEAN, CHECK WIRE

CLEAN BOTH

ADJUST ICE THICKNESS SENSOR TO CORRECT THICKNESS

Troubleshooting/Ice Machine Alarms

ICE MACHINE ALARM

ICE MACHINE ERROR SHUTDOWN MAX HARVEST

ICE BRIDGE THICKNESS TOO SMALL

ICE BRIDGE THICKNESS TOO LARGE

PURGE VALVE DOES NOT OPEN, WATER MELTS ICE BRIDGE

INCOMPLETE ICE FORMATION

CHECK AND ADJUST ICE THICKNESS SENSOR

CHECK PURGE VALVE CLEAN WATER DISTRIBUTOR/SPILLWAY SURFACE

CHECK CURTAIN FOR RESTRICTION CURTAIN OUT OF POSITION

CURTAIN SWITCH DOES NOT SHOW OPEN WHEN CURTAIN OPENS

TEMPERATURE IS TOO COLD

HOT GAS VALVE DOES NOT OPEN

HARVEST ASSIST NOT WORKING OR OUT OF POSITION

DAMAGED EVAPORATOR

FAN MOTOR STAYS ON DURING HARVEST

CONTACT SCOTSMAN TECHNICIAN

ADD COLD WEATHER PACKAGE OR WAIT FOR WARMER WEATHER

CONTACT SCOTSMAN TECHNICIAN

ADJUST HARVEST ASSIST POSITION OR CONTACT SCOTSMAN TECHNICIAN

CONTACT SCOTSMAN TECHNICIAN

ICE MACHINE ERROR SHUTDOWN MAX FREEZE

PUMP NOT WORKING/HOSE DISCONNECTED

DIRTY AIR FILTERS AND/OR CONDENSER

TOO HOT OUTSIDE

WATER LEAK

COMPRESSOR NOT WORKING

LOW ON REFRIGERANT

INCORRECT SUPER HEAT

CHECK PUMP AND HOSE

CHECK/CLEAN FILTERS/CONDENSER

WAIT FOR IT TO COOL DOWN

CHECK PURGE VALVE/HOSE AND INLET VALVE/HOSE

CONTACT SCOTSMAN TECHNICIAN

CHECK ICE THICKNESS SENSOR ADJUST/CLEAN ICE THICKNESS SENSOR

Troubleshooting/Ice Machine Alarms

ICE MACHINE ALARM LIKELY CAUSE OF ALARM

ICE MACHINE ERROR DISCHARGE TEMP SENSOR FAILURE

ICE MACHINE ERROR HIGH DISCHARGE TEMP

ICE MACHINE ERROR SUMP TEMPERATURE

FAN/FAN BLADE VIBRATES

COMPRESSOR VIBRATES

WATER PUMP VIBRATES

SUMP OVERFLOWING

DISCHARGE TEMP SENSOR

DISCHARGE TEMP SENSOR OR FANS

SUMP TEMPERATURE PROBE

BENT/BROKEN BLADE OR MOUNT

MOUNTING BOLTS

PUMP BEARINGS WORN

WATER LEVEL SENSOR

CONTACT SCOTSMAN TECHNICIAN

-CHECK FANS -CONTACT SCOTSMAN TECHNICIAN

-CHECK SUMP TEMPERATURE PROBE -CONTACT SCOTSMAN TECHNICIAN

REPLACE BLADE OR MOUNT

TIGHTEN BOLTS

REPLACE PUMP

-REPLACE/CLEAN SENSOR

-RUN CLEAN CYCLE TO RESET SENSOR

BILL

ALARM

Bill Validator Troubleshooting

BILL PATH JAMMED/LED FLASHES (1)

DISABLED FROM SYSTEM/LED FLASHES (2)

NEEDS CLEANING OR THE LOWER HOUSING HAS BEEN REMOVED/LED FLASHES (3)

CROSS CHANNEL BLOCKED/LED FLASHES (4)

MAGAZINE REMOVED/LED FLASHES (5)

UNIT FAILURE/LED FLASHES CONTINUOUS SLOW

STACKER FULL/LED FLASHES CONTINUOUS FAST

BILL STUCK IN VALIDATOR

MACHINE OR COIN MECHANISM IN ALARM

DIRTY SENSORS/ROLLERS OR THE LOWER HOUSING ISN’T INSERTED FULLY

BILL VALIDATOR INTERNAL ERROR

MAGAZINE REMOVED/NOT FULLY ATTACHED

BILL VALIDATOR INTERNAL ERROR

BILL VALIDATOR IS FULL AND CANNOT ACCEPT ANY MORE BILLS

REMOVE STUCK BILL

-FIX ANY ALARMS ON THE PLC -FIX ANY ALARMS ON THE COIN MECHANISM -CYCLE THE ICE TALK POWER

CLEAN SENSORS AND ROLLERS REINSERT THE LOWER HOUSING FULLY

REPLACE BILL VALIDATOR

REATTACH CASSETTE

REPLACE BILL VALIDATOR

EMPTY CASSETTE

Coin Mechanism Troubleshooting

COIN MECH ALARM

COIN JAM ALARM

DISABLED BY VENDOR/ALL COINS INHIBITED

COMMS ERROR/NO VMC COMMUNICATION

TUBE JAM ALARM

HARDWARE ERROR

ACCEPT GATE ERROR

ALERT DISPENSER A,B,C,D, AND/OR E

ALTERNATING RED AND GREEN LED LIGHTS

COIN STUCK IN COIN MECH

DOOR OPEN OR OTHER ALARM ON MACHINE

NO COMMUNICATION WITH ICE TALK

COIN STUCK IN COIN CASSETTE TUBE

INTERNAL ERROR

COIN JAM

COIN JAM AND/OR DISPENSER ARM OUT OF POSITION

INTERNAL ERROR

REMOVE STUCK COIN OR FOREIGN MATERIAL

-CLOSE DOOR -CLEAR OTHER MACHINE ALARMS -CYCLE POWER ON ICE TALK

-CHECK WIRING FROM COIN MECH TO ICE TALK

-CYCLE POWER ON ICE TALK

REMOVE STUCK COIN OR FOREIGN MATERIAL

REPLACE COIN MECH

REMOVE STUCK COIN OR FOREIGN MATERIAL

REMOVE THE CASSETTE AND REMOVE STUCK COIN OR FOREIGN MATERIAL. THEN PRESS THE YELLOW BUTTON TWICE. ONCE ALL THE ARMS ARE BACK INTO POSITION REPLACE THE CASSETTE.

REPLACE COIN MECH

PLC/ICETALK

PLC and ICETALK Troubleshooting

NO COMM ALARM

PLC DISCONNECTED (IT)

SIGNAL DROP

COMMUNICATION HAS BEEN LOST BETWEEN THE ICE TALK AND PLC

OUT OF ICE/VEND TIME OUT

DOOR OPEN

FAULT DURING VEND CYCLE

DOOR SENSOR/SWITCH NOT SENSING DOOR CLOSURE

-MAKE SURE ANTENNA IS ATTACHED AND NOT DAMAGED

-TURN THE POWER TO THE ICE TALK OFF THEN TURN IT BACK ON AGAIN

-VERIFY THE ETHERNET CABLE IS NOT CUT

-VERIFY BOTH ENDS OF THE CABLE HAVE A SECURE CONNECTION

-VERIFY THERE ARE NO PLC OR ICE

TALK FAILURES

-REPLACE CABLE

-VERYIFY YOU HAVE ICE IN THE BIN

-VERIFY YOU HAVE BAGS ON THE MACHINE

-MAKE SURE ALL MOTORS ARE WORKING

-CHECK THAT THE BAG FILL SENSOR IS WORKING AND THE SESITIVITY IS ADJUSTED PROPERLY

-VERIFY THE ICE AT THE BOTTOM OF THE BIN IS NOT ALL CRUSH

-VERIFY DOOR IS SHUT ALL THE WAY

-VERIFY THE DOOR COMES IN CONTACT WITH THE DOOR SENSOR/SWITCH

OUT OF BAGS

DRAWER FAULT (KI510 & KI810)

BAG SENSOR SENSING BAG BACKING PLATE

VERIFY THERE ARE MORE THAN 50 BAGS ON THE MACHINE

-VERIFY CAM TAB IS LOCATED OVER THE CAM SENSOR

DRAWER DIDN’T RETURN TO THE HOME POSITION

-UV SYSTEM FAILURE

-VERIFY THE SENSOR LED IS LIT WITH TAB INFRONT OF THE SENSOR

-VERIFY CAM CHAIN IS NOT BROKEN

-VERIFY RO TANK IS NOT EMPTY

WATER FAULT

WATER FLOW FAULT

-OW PLUG NOT JUMPED OUT (2019 AND OLDER MODELS)

-VERIFY THE OW PLUG HAS A JUMPER AND IS MAKING A GOOD CONNECTION (2019 AND OLDER)

-VERIFY THE BLUE UV LIGHT IS ON

-VERIFY THE FUSE IN THE UV IS GOOD

-VERIFY THE UV BULB IS GOOD

-VERIFY WATER SYSTEM IS ENABLED

-VERIFY DEMAND PUMP IS WORKING

PLC DID NOT SENSE ONE GALLON OF WATER WITHIN 90 SECONDS

-VERIFY CUT OFF VALVE NEAR UV LIGHT IS OPEN

-VERIFY FILTERS ARE NOT CLOGGED

General Troubleshooting

PROBLEM

MACHINE READS “SOLD OUT”

MACHINE READS “BAD MEM3” OR “INIT”

MACHINE WILL TAKE MONEY, DOESN’T REGISTER AND DOESN’T VEND OR RETURN MONEY

ICE COMING OUT OF CHUTE WITHOUT A BAG

MACHINE WILL TAKE MONEY, SAYS “VEND” ON THE DISPLAY BUT NEVER VENDS A BAG, AND NO ALARMS

BILL VALIDATOR TAKES BILL THEN BECOMES DISABLED

ICE BAG NOT FILLING UP

WILL NOT VEND WATER

PROBABLE SOLUTION

-CHECK FOR ANY ACTIVE ALARMS ON THE SEIMANS

TOUCH SCREEN, CORRECT ALARM

-VERIFY DOORS ARE CLOSED

-VERIFY THE MACHINE IS NOT OUT OF ICE

-VERIFY THE MACHINE IS NOT OUT OF BAGS

-TURN THE PLC BREAKER OFF AND THEN BACK ON

REPLACE THE SD CARD IN THE ICE TALK (1 OR 2 GIGS ONLY) , OR DELETE THE FILES ON THE CARD

VERIFY THERE ARE NO COINS JAMMED IN THE COIN MECH

-VERIFY THE MACHINE HAS BAGS

-VERIFY THERE ARE MORE THAN 50 BAGS ON THE MACHINE

-VERIFY THE BAGS ARE NOT ON BACKWARDS

-VERIFY THE BLOWER IS OPERATIONAL

-VERIFY THERE IS NOT A PLC DISCONNECT ALARM

-VERIFY THERE IS NOT A BAG STUCK

-VERIFY THE BAG FILL SENSOR IS NOT LIT UP WHEN THERE IS NOT ANY ICE INFRONT OF IT

-(KI510 & KI810) VERIFY THE CAM TAB IS INFRONT OF THE CAM SENSOR.

-(KI510 & KI810) VERIFY THE CAM SENSOR LED IS LIT

-(KI510 & KI810) VERIFY THE DRAWER CHAIN ISN’T LOOSE, BROKE, OR STRECHED

-VERIFY THERE ARE NO ERRORS ON THE COIN MECH

-VERIFY THE BILL BOX IS FULLY ENGAGED AND SECURE

-VERYIFY YOU HAVE ICE IN THE BIN

-VERIFY THERE IS NOT ANY ICE STUCK IN THE CHUTE ABOVE THE BAGS

-MAKE SURE ALL MOTORS ARE WORKING

-CHECK THAT THE BAG FILL SENSOR IS WORKING AND THE SESITIVITY IS ADJUSTED PROPERLY

-VERIFY THAT THE BAG FILL SENSOR IS SECURE AND THE WINGNUTS THAT HOLD IT IN PLACE HAVEN’T LOOSENED.

-VERIFY THE ICE AT THE BOTTOM OF THE BIN IS NOT ALL CRUSHED

-VERIFY THE AUGER OVERRLOAD IS NOT TRIPPED, RESET BY PRESSING THE BLUE BUTTON

-(KI510 & KI810) VERIFY THE DRAWER SHIM WING NUTS HAVE NOT BECOME LOOSE

-VERIFY THAT WATER HAS BEEN ENABLED

-CHECK FOR ANY ALARMS ON THE SEIMANS TOUCH SCREEN

-VERIFY YOU HAVE WATER PRESSURE COMING FROM YOUR SOURCE

-VERIFY THE FILTERS ARE NOT CLOGGED

-VERIFY THE UV SYSTEM HAS POWER AND THE BLUE LED

LIGHT ON THE UV IS LIT

-(RO) VERIFY THE HOLDING TANK IS FULL

-(RO) VERIFY THE DEMAND PUMP IS WORKING

-VERIFY THE CUTOFF VALVE NEAR THE UV IS ON