AFC built for fire

www.australianfirecontrol.com.au

BOUNDARY PROTECTION

DEFENDER SCREENS FIRE ATTENUATION SCREENS Building on a boundary [Class 2-9] OR BAL FZ [Class 1, 1a & 10] AS3959-2009

• • • • • • • •

Note that the angle of the light relative to the mesh may reduce the light into the room more than expected. AFC Defender Screen provides radiation attenuation to protect windows close to a boundary [Class 2-9] or to provide BAL FZ performance to AS3959-2009 for Class 1, 1a & 10 construction. Fire Engineers use this data in their design and calculations to determine whether the radiation attenuation is sufficient to prevent non-piloted ignition and therefore fire spread to nearby materials/buildings.

10 Y

Z

10 YE

Z

Subject to

maintenance

SIZES Width 750 900 1200 1500 2400 3000

advantages

1YEAR0

OPERATIONAL WARRANT Y*

SIZES

AFC Defender - Radiation Attenuation Screen Specially developed for Fire Engineers and Architects to be used in lieu of deemed-to-satisfy systems, this solution can also provide security.

• • •

STRUCTUR WARRANT AL Y

ENDER SERIES BA DEF LF

Assessed to AS1530 section 8.1 using radiant heat flux exposure up to & including 40kW/m2 [BAL40]. Radiation attenuation achieved 42% to 50% of radiant heat flux. Furnace Temperature > 850C Complies with dimensional requirements of AS3959 section 9.5.1.A ‘Construction of Buildings in Bushfire Prone Areas’ - 2009 Impact resistance equivalent to 4kg mass @15m/s 304mm Stainless Steel 0.90mm Wire Diameter 1.5mm x 1.5mm Aperture 10 strands per inch 42% Open Area.

ATIONAL OPER WA AR

Height 3000 3000 3000 2400 2400 2100

Available with powder coated perimeter frame. Can fulfil a security function. Allows the use of standard sliding or sash [with restrictor] windows behind. Minimal side wall clearance/usage requirements.

SYSTEM DETAIL - SAMPLE SHOP DRAWING SYSTEM NOTES: • Assessed to AS1530 section 8.1 using radiant heat flux exposure up to & including 40kW/m2 [BAL40]. • Radiation attenuation achieved 42% to 50% of radiant heat flux. • Furnace Temperature > 850C • Complies with dimensional requirements of AS3959 section 9.5.1.A ‘Construction of Buildings in Bushfire Prone Areas’ - 2009 • Impact resistance equivalent to 4kg mass @15m/s • 304mm Stainless Steel • 0.90mm Wire Diameter • 1.5mm x 1.5mm Aperture • 10 strands per inch 42% Open Area.

Opening width A

Height 3000 3000 3000 2400 2400 2100

DEFENDER SCREEN

DETAIL CC

Exsiting window

DETAIL CC Opening height

SIZES Width 750 900 1200 1500 2400 3000

AFC built for fire

“In the game since 1979”

Phone: 9399 6957 Address: 17 Williams Road Kelmscott WA 6111 Email: Sales@AustralianFireControl.com.au

Project Address: ________________________________________________ Project Ref No: ________________________________________________

AFC Defender Screen (radiation attenuation screen)

Opening Width: ________________________________________________ Opening Height: ________________________________________________

D8 x 75mm Dynabokt @ 300mm centers

Colour Selection:

(40 x 40 x 3 thick) mm angle (four sides) Anotec® Silver Grey

Windspray®

Evening Haze®

Ironstone®

Wilderness®

Jasper®

Black (C/B Night Sky)

Blue Ridge®

Surfmist®

SHOP DRAWING APPROVAL

OTHER PLEASE SPECIFY

SCALE: NTS

IMPORTANT INFORMATION REGARDING THIS SHOP DRAWING.

A

This is a production document based on our understanding of project requirements.

(5x25)mm Mushroom head screws with rubber gromets @ 300mm centers

SECTION AA

It is important to note that material will be manufactured from this information. Whilst we understand that it is our responsibility to determine all manufacturing information we ask that you review this document as a double check to assist in having the correct product delivered to site. Drawn by: ______________________________________________ Date: _____/_____/_____ Shop Drawing Approval Name: _____________________________ Sign: _______________________________ Date: _____/_____/_____

How to specify

Radiation Attenuation Mesh shall be Australian Fire Control’s (08 9399 6957) proprietary AFC Defender Radiation Attenuation Screen [System FRBCAFC001] supplied and installed by an accredited installer. System shall be assessed to AS15030 section 8.1 and comply with AS3959 section 9.5.1.A. Radiation attenuation when subjected to 40kW/m2 radiant heat flux shall be in the range of minimum 42% to maximum 50%.

www.AustralianFireControl.com.au

programme

ENDER SERIES BA DEF LF

The AFC Defender system consists of a perimeter aluminum frame that can be powder coated a standard colour. This is fixed to the perimeter of the window opening using a continuous angle. The mesh consists of a 0.9mm thick woven 304 stainless steel which is coated black to reduce the reflection of light and maximize the clarity of the view. The free area of the mesh is 42%.

1YEAR0

Phone: 9399 6957| Address: 17 Williams Road Kelmscott WA 6111 |Email: Sales@AustralianFireControl.com.au

Y ANT RR

facts and figures

Y ANT RR

DEFENDER SCREENS

TRUCTURAL W RS A EA


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.