KEY PLAN:
INDEX OF DRAWINGS
SAFEHUB 1561 QUEBEC STREET, VANCOUVER, BC CANADA V6A 0G5 PROJECT CONTACTS ARCHITECT OF RECORD: COMPANY: HCMA ARCHITECTURE + DESIGN CONTACT: JAY LIN ADDRESS: 675 W HASTINGS ST. #400 VANCOUVER, BC, CANADA V6B 1N2 T: 604.732.6620 E: VANCOUVER@HCMA.CA
DESIGNER: COMPANY: LUCINE DESIGN GROUP CONTACT: LUCINE LU ADDRESS: 5645 BARKER AVE. BURNABY, BC, CANADA V5H 3Z5 T: 778.999.3131 E: LUCINE.LU@HOTMAIL.COM
LOT: 353 BLOCK: N/A
ACCESSORY ADDENDUM
N.I.C P
NOT IN CONTRACT PAINT
ALUM.
ALUMINUM
PL
PLASTIC LAMINATE
AFF.
ABOVE FINISHED FLOOR
PLY
PLYWOOD
BOH
BACK OF HOUSE
R
RADIUS
CL
CEILING
RB
RESILIENT BASE
C
CONCRETE
REQ'D
REQUIRED
CONT'D
CONTINUED
HU.
SQUARE FEET
D.
DIAMETER
S
SOLID SURFACE
ELEV.
ELEVATION
T
TILE
EQ.
EQUAL
TYP.
TYPICAL
EXT.
EXTERIOR
U.N.O.
UNLESS NOTED OTHERWISE
FIRE EXTINGUISHER CABINET (AS
U
UPHOLSTERY
APPLICABLE)
W/
WITH
FOH
FRONT OF HOUSE
WC
WATER CLOSET
H
HEIGHT
WD
WOOD
MAX.
MAXIMUM
WV
WOOD VENEER
HT.
MECHANICAL
WT.
WEIGHT
3. BUILDING CLASSIFICATION: GROUP A, DIVISION 2 GROUP D ART GALLERIES OFFICES RADIO STATIONS AUDITORIA EXHIBITION HALLS GROUP E LECTURE HALLS SHOPS MUSEUMS RESTAURANTS
SITE LOCATION MAP
PLAN: EPP46205
BY COMPARING THE CODE REQUIREMENTS OF GROUP A2, D AND E, THE BUILDING OF SAFEHUB NEEDS TO ACHIEVE THE REQUIREMENTS BASED ON THE BCBC 3.2.2.24. GROUP A, DIVISION 2, UP TO 6 STOREYS, ANY AREA, SPRINKLERED. 4. BUILDING MAJOR OCCUPANCY CLASSIFICATION: REFER TO BCBC 3.2.2.24 GROUP A, DIVISION 2, UP TO 6 STOREYS, ANY AREA, SPRINKLERED 5. ADJOINING MAJOR BUILDING OCCUPANCY CLASSIFICATIONS: REFER TO BCBC #3.2.2.24 GROUP A, DIVISION 2, UP TO 6 STOREYS, ANY AREA, SPRINKLERED 6. PROJECT OCCUPANCY CLASSIFICATION: REFER TO BCBC 3.2.2.24 CLASSIFICATION GROUP A DIVISION 2
ROOM NAME/ NUMBER
O.L. FACTORS
PERMITTED OCCUPANT LOAD
PROPOSED OCCUPANT LOAD
LOBBY
85 (917)
1.85 (reading or writing rooms or lounges)
45
30
11. TYPE OF BUILDING CONSTRUCTION ALLOWED: REFER TO BCBC 3.2.2.24. NONCOMBUSTIBLE CONSTRUCTION
GIFT SHOP
62 (666.5)
4.6 (personal services shops)
13
10
12. FLAME SPREAD RATING REQUIREMENTS: REFER TO BCBC 3.1.13.2. 150 MAX. FLAME SPREAD RATING FOR WALLS AND CEILING (SPRINKLERED)
EXHIBITION
73 (786)
0.4 (standing space)
182
60
CAFE
1088 (101)
1.2 (dining, beverage and cafeteria space)
84
40
KEYNOTE
#
#
KITCHEN/STAFF WC
15 (163)
9.3 (kitchens)
1
1
SECURITY
4.5 (51)
1.85 (reading or writing rooms or lounges)
2
1
EXPERIENCE CENTRE EARTHQUAKE
149.5 (1610)
9.3 (school shops and vocational rooms)
16
34
EXPERIENCE CENTRE FIRE
1652.5 (153.5)
9.3 (school shops and vocational rooms)
16
23
FIRST AID ROOM
11.5 (124.5)
4.6 (laboratories in schools)
2
2
THEATRE
54.5 (587.5)
0.75 (stages for theatrical performance)
72
24
FURN/FIXTURE TAG # ID#.#
FINISH TAG
CH-# -
ELEVATION
ID#.#
WALL TYPE
#
SECTION
CEILING HEIGHT/ TYPE / FINISH
#
1 CS
SITE LOCATION MAP SCALE: N/A
KEY PLAN
SITE PLAN
139'-9"
THEATRE CONTROL ROOM
5.5 (60.5)
1.85 (reading or writing rooms or lounges)
2
1
GAMING ROOM
69.5 (748)
9.3 (school shops and vocational rooms)
7
14
WORKSHOP
90 (968)
1.85 (reading or writing rooms or lounges)
39
30
MULTIPURPOSE ROOM
89.5 (967)
1.85 (reading or writing rooms or lounges)
48
56
MEETING ROOMS (2)
44.5 (479)
0.95 (space with non-fixed seats and tables)
46
12
OFFICE LOUNGE
38.5 (414.5)
1.85 (reading or writing rooms or lounges)
20
18
OPEN OFFICE
57.5 (623)
1.85 (reading or writing rooms or lounges)
31
15
9.3 (offices)
2
WEST GARDEN 36'-9"
87'-11"
53'-1"
PRIVATE OFFICE
YYYY.MM.DD
ISSUE 9
YYYY.MM.DD
ISSUE 8
YYYY.MM.DD
ISSUE 7
YYYY.MM.DD
ISSUE 6
YYYY.MM.DD
ISSUE 5
YYYY.MM.DD
ISSUE 4
YYYY.MM.DD
ISSUE 3
YYYY.MM.DD
ISSUE 2
YYYY.MM.DD
ISSUE 1
2019.04.11
COVER SHEET
INTERIOR DESIGN SHEET #
SHEET TITLE
ID 1.0
LEVEL 1 FURNITURE PLAN
ID 1.1
LEVEL 2 FURNITURE PLAN
ID 1.2
LEVEL 3 FURNITURE PLAN
ID 2.0
CAFE & EXHIBITION FURNITURE PLAN
ID 3.0
CAFE & EXHIBITION CONSTRUCTION PLAN
ID 4.0
CAFE & EXHIBITION REFLECTED CEILING FINISH PLAN
ID 5.0
CAFE & EXHIBITION LIGHTING PLAN
ID 6.0
CAFE & EXHIBITION POWER AND DATA PLAN
ID 7.0
CAFE & EXHIBITION FINISH PLAN
ID 8.0
CAFE & EXHIBITION ELEVATIONS
ID 8.1
CAFE & EXHIBITION ELEVATIONS
ID 8.2
CAFE & EXHIBITION ELEVATIONS
ID 8.3
CAFE & EXHIBITION ELEVATIONS
ID 8.4
CAFE & EXHIBITION ELEVATIONS
ID 8.5
CAFE & EXHIBITION ELEVATIONS
ID 9.0
BAR PLAN / ELEVATIONS
ID 9.1
BAR ELEVATIONS
ID 9.2
BANQUETTE PLAN / ELEVATIONS
ID 9.3
BAR TABLE AND TOUCHSCREEN PLAN / ELEV
ID 10.0
BAR SECTIONS
ID 10.1
BANQUETTE / TOUCHSCREEN / BAR TABLE SECTIONS
COPYRIGHT: This drawing/design is and at all times remains the exclusive property of Lucine Design interior design inc and cannot be used or duplicated without written consent. This drawing shall not be scaled. The general contractor shall verify all dimensions, datums and levels prior to commencement of work. Any errors and omissions are to be reported to the designer immediately.
REVISION: DATE
NO.
DESCRIPTION
18.5 (200)
2
KITCHEN
30 (325)
1.2 (dining, beverage and cafeteria space)
25
16
RADIO ROOM
4 (44)
1.85 (reading or writing rooms or lounges)
2
1
13. EXIT LIGHT REQUIREMENT WITH ILLUMINATION LEVELS: REFER TO BCBC 3.2.7.1. AN EXIT SHALL PROVIDE ILLUMINATION WITH AN AVERAGE LEVEL NOT LESS THAN 50 LX AT FLOOR OR TREAD LEVEL 14. LIGHTING FOR PUBLIC AREAS: REFER TO TABLE 9.34.2.7. STORAGE ROOMS WITH 50LX MINIMUM ILLUMINATION. PUBLIC WATER CLOSET ROOMS WITH 100LX MINIMUM ILLUMINATION. RECREATION ROOMS WITH 100LX MINIMUM ILLUMINATION. 15. EXIT CAPACITY & EXIT CAPACITY MULTIPLICATION FACTOR: REFER TO BCBC 3.4.3.2. (1) (B) THE MINIMUM AGGREGATE REQUIRED WIDTH OF EXITS SERVING FLOOR AREAS INTENDED FOR ASSEMBLY OCCUPANCIES, RESIDENTIAL OCCUPANCIES, BUSINESS AND PERSONAL SERVICES OCCUPANCIES, MERCANTILE OCCUPANCIES, AND INDUSTRIAL OCCUPANCIES SHALL BE DETERMINED BY MULTIPLYING THE OCCUPANT LOAD OF THE AREA SERVED BY 8MM PER PERSON. NUMBER OF PEOPLE X MULTIPLICATION FACTOR: 792 PERSONS X 8 MM / PERSON = 6336 MM EXIT CAPACITY: 6336/1066 (42”) = 5.94 DOORS (6 DOORS)
LUCINE LU T:778-999-3131 E:Lucine.lu@hotmail.com
16. TRAVEL DISTANCE REQUIREMENTS: REFER TO BCBC 3.4.2.4. AND BCBC 3.4.2.5. (C) REQUIRED: TRAVEL DISTANCE TO THE EXIT SHOULD BE LESS THAN 45 M PROVIDED: TRAVEL DISTANCE TO THE EXIT SHOULD BE LESS THAN 29.3 M 17. DISTANCES BETWEEN EXITS (INCLUDE MINIMUM DISTANCE): REFER TO BCBC 3.4.2.3. REQUIRED: ONE HALF THE MAXIMUM DIAGONAL OF THE FLOOR AREA BUT NOT LESS THAN 9 M PROVIDED: LESS THAN 26 M, MORE THAN 9 M 18. NUMBER OF EXITS: REFER TO BCBC 3.4.2.1. (1) EACH FLOOR AREA HAS 2 EXITS MINIMUM REQUIRED: 6 EXITS PROVIDED: 13 EXITS 19. MINIMUM WIDTHS OF EXITS: REFER TO BCBC 3.4.3.2. (8) EXIT CORRIDORS AND PASSAGEWAYS TO BE 1100 MM MINIMUM. STAIRS TO BE 1100 MM MINIMUM. DOORWAYS TO BE 800 MM MINIMUM. 20. TOTAL WIDTH OF EXITS:REFER TO BCBC 3.4.3.2.(8) REQUIRED: 1066 mm / EXIT X 6 = 6396 mm (251.8") PROVIDED: 1066 mm / EXIT X 13 = 13858 mm (545.5") 21. BARRIER FREE DESIGN CONFORMANCE REQUIREMENTS: REQUIREMENTS TO BE IN CONFORMANCE WITH BCBC SECTION 3.7 AND 3.8.
CLIENT INFORMATION:
BCIT 3700 WILLINGDON AVENUE BURNABY, BC CANADA V5G 3H2 604-434-0000 PROJECT INFORMATION:
SAFEHUB 1561 QUEBEC STREET VANCOUVER, BC CANADA V6A 0G5 DRAWING NAME:
COVER SHEET
GUEST PARKING 78'-8"
SIDEWALK
EET
FIREMAN TRAINING DRILLS AREA
129'-6"
R SWITCHMEN ST
15'-1"
30'-1"
27'-7"
95 °
STAFF PARKING FIRE TRUCK TEMPORARY PARKING
SIDEWALK
YYYY.MM.DD
ISSUE 10
10. MINIMUM FIRE RESISTANCE RATING REQUIRED: REFER TO BCBC 3.2.2.24. FLOOR ASSEMBLIES SHALL BE FIRE SEPARATIONS WITH A FIRE-RESISTANCE RATING NOT LESS THAN 1 H. MEZZANINES SHALL HAVE A FIRE-RESISTANCE RATING NOT LESS THAN 1 H.
AREA SQ. M (SQ. FT.)
DOOR NUMBER
#
LEVEL 3 OCCUPANT LOAD: 319 319-10=309/2=154.5 154.5 MALES, 154.5 FEMALES WATER CLOSETS: MALE: 4 FEMALE: 7 UNISEX: 1 LAVATORIES: MALE: 2 FEMALE: 4 UNISEX: 1
ROOM NAME
SYMBOL LEGEND
#
LEVEL 2 OCCUPANT LOAD: 87 87-10=77/2=38.5 38.5 MALES, 38.5 FEMALES WATER CLOSETS: MALE: 1 FEMALE: 2 UNISEX: 1 LAVATORIES: MALE: 1 FEMALE: 1 UNISEX: 1
TOTAL WATER CLOSETS: 29 TOTAL LAVATORIES: 17
8. OCCUPANCY LOAD TABLE WITH ROOM SIZES: REFER TO BCBC 3.1.17.1
VANCOUVER DISTRICT
#
LEVEL 1 OCCUPANT LOAD: 386 386-10=376/2=188 188 MALES AND 188 FEMALES WATER CLOSETS: MALE: 4 FEMALE: 8 UNISEX: 1 LAVATORIES: MALE: 2 FEMALE: 4 UNISEX: 1
CS
YYYY.MM.DD
ISSUE 11
7. GOVERNING CODE SECTION: REFER TO BCBC 3.2.2.24
DISTRICT LOT: FC
#
9. WASHROOMS & HEALTH REQUIREMENTS: REFER TO BCBC 3.7.2.2. WATER CLOSETS REFER TO BCBC 3.7.2.2.A LAVATORIES REFER TO BCBC 3.7.2.3.
2. PROJECT GROSS AREA: 1207.73 S.M.
ACC ADD.
FEC
LEGAL DESCRIPTION
REQUESTED MAXIMUM TOTAL OCCUPANT LOAD: 792
1. GROSS BUILDING AREA: 2322.57 S.M., 3 STOREY BUILDING AND BUILDING HEIGHT TO BE 13.3 M
STANDARD ABBREVIATIONS
CLIENT COMPANY: BRITISH COLUMBIA INSTITUTE OF TECHNOLOGY ADDRESS: 3700 WILLINGDON AVE. BURNABY, BC, CANADA V5G 3H2 T: 604.432.8612
BUILDING CODE ANALYSIS (BASED ON BCBC 2012)
ISSUE 12
DRAWN BY:
LUCINE LU
CHECKED BY: KATHRYN LANGE
SIDEWALK
SIDEWALK
152'-9"
SITE PLAN SCALE: 1/64" = 1'-0"
DATE:
11.04.2019
SCALE:
AS NOTED
FILE NAME:
COMMERCIAL
FILE NUMBER: 01
QUEBEC STREET
2 CS
ROBIN MCINTOSH
85 °
OUTDOOR FEATURE DESIGN / SEATING
3 CS
KEY PLAN SCALE: 1/32" = 1'-0"
DRAWING NUMBER:
OF22