Sample Construction Drawings

Page 1

KEY PLAN:

INDEX OF DRAWINGS

SAFEHUB 1561 QUEBEC STREET, VANCOUVER, BC CANADA V6A 0G5 PROJECT CONTACTS ARCHITECT OF RECORD: COMPANY: HCMA ARCHITECTURE + DESIGN CONTACT: JAY LIN ADDRESS: 675 W HASTINGS ST. #400 VANCOUVER, BC, CANADA V6B 1N2 T: 604.732.6620 E: VANCOUVER@HCMA.CA

DESIGNER: COMPANY: LUCINE DESIGN GROUP CONTACT: LUCINE LU ADDRESS: 5645 BARKER AVE. BURNABY, BC, CANADA V5H 3Z5 T: 778.999.3131 E: LUCINE.LU@HOTMAIL.COM

LOT: 353 BLOCK: N/A

ACCESSORY ADDENDUM

N.I.C P

NOT IN CONTRACT PAINT

ALUM.

ALUMINUM

PL

PLASTIC LAMINATE

AFF.

ABOVE FINISHED FLOOR

PLY

PLYWOOD

BOH

BACK OF HOUSE

R

RADIUS

CL

CEILING

RB

RESILIENT BASE

C

CONCRETE

REQ'D

REQUIRED

CONT'D

CONTINUED

HU.

SQUARE FEET

D.

DIAMETER

S

SOLID SURFACE

ELEV.

ELEVATION

T

TILE

EQ.

EQUAL

TYP.

TYPICAL

EXT.

EXTERIOR

U.N.O.

UNLESS NOTED OTHERWISE

FIRE EXTINGUISHER CABINET (AS

U

UPHOLSTERY

APPLICABLE)

W/

WITH

FOH

FRONT OF HOUSE

WC

WATER CLOSET

H

HEIGHT

WD

WOOD

MAX.

MAXIMUM

WV

WOOD VENEER

HT.

MECHANICAL

WT.

WEIGHT

3. BUILDING CLASSIFICATION: GROUP A, DIVISION 2 GROUP D ART GALLERIES OFFICES RADIO STATIONS AUDITORIA EXHIBITION HALLS GROUP E LECTURE HALLS SHOPS MUSEUMS RESTAURANTS

SITE LOCATION MAP

PLAN: EPP46205

BY COMPARING THE CODE REQUIREMENTS OF GROUP A2, D AND E, THE BUILDING OF SAFEHUB NEEDS TO ACHIEVE THE REQUIREMENTS BASED ON THE BCBC 3.2.2.24. GROUP A, DIVISION 2, UP TO 6 STOREYS, ANY AREA, SPRINKLERED. 4. BUILDING MAJOR OCCUPANCY CLASSIFICATION: REFER TO BCBC 3.2.2.24 GROUP A, DIVISION 2, UP TO 6 STOREYS, ANY AREA, SPRINKLERED 5. ADJOINING MAJOR BUILDING OCCUPANCY CLASSIFICATIONS: REFER TO BCBC #3.2.2.24 GROUP A, DIVISION 2, UP TO 6 STOREYS, ANY AREA, SPRINKLERED 6. PROJECT OCCUPANCY CLASSIFICATION: REFER TO BCBC 3.2.2.24 CLASSIFICATION GROUP A DIVISION 2

ROOM NAME/ NUMBER

O.L. FACTORS

PERMITTED OCCUPANT LOAD

PROPOSED OCCUPANT LOAD

LOBBY

85 (917)

1.85 (reading or writing rooms or lounges)

45

30

11. TYPE OF BUILDING CONSTRUCTION ALLOWED: REFER TO BCBC 3.2.2.24. NONCOMBUSTIBLE CONSTRUCTION

GIFT SHOP

62 (666.5)

4.6 (personal services shops)

13

10

12. FLAME SPREAD RATING REQUIREMENTS: REFER TO BCBC 3.1.13.2. 150 MAX. FLAME SPREAD RATING FOR WALLS AND CEILING (SPRINKLERED)

EXHIBITION

73 (786)

0.4 (standing space)

182

60

CAFE

1088 (101)

1.2 (dining, beverage and cafeteria space)

84

40

KEYNOTE

#

#

KITCHEN/STAFF WC

15 (163)

9.3 (kitchens)

1

1

SECURITY

4.5 (51)

1.85 (reading or writing rooms or lounges)

2

1

EXPERIENCE CENTRE EARTHQUAKE

149.5 (1610)

9.3 (school shops and vocational rooms)

16

34

EXPERIENCE CENTRE FIRE

1652.5 (153.5)

9.3 (school shops and vocational rooms)

16

23

FIRST AID ROOM

11.5 (124.5)

4.6 (laboratories in schools)

2

2

THEATRE

54.5 (587.5)

0.75 (stages for theatrical performance)

72

24

FURN/FIXTURE TAG # ID#.#

FINISH TAG

CH-# -

ELEVATION

ID#.#

WALL TYPE

#

SECTION

CEILING HEIGHT/ TYPE / FINISH

#

1 CS

SITE LOCATION MAP SCALE: N/A

KEY PLAN

SITE PLAN

139'-9"

THEATRE CONTROL ROOM

5.5 (60.5)

1.85 (reading or writing rooms or lounges)

2

1

GAMING ROOM

69.5 (748)

9.3 (school shops and vocational rooms)

7

14

WORKSHOP

90 (968)

1.85 (reading or writing rooms or lounges)

39

30

MULTIPURPOSE ROOM

89.5 (967)

1.85 (reading or writing rooms or lounges)

48

56

MEETING ROOMS (2)

44.5 (479)

0.95 (space with non-fixed seats and tables)

46

12

OFFICE LOUNGE

38.5 (414.5)

1.85 (reading or writing rooms or lounges)

20

18

OPEN OFFICE

57.5 (623)

1.85 (reading or writing rooms or lounges)

31

15

9.3 (offices)

2

WEST GARDEN 36'-9"

87'-11"

53'-1"

PRIVATE OFFICE

YYYY.MM.DD

ISSUE 9

YYYY.MM.DD

ISSUE 8

YYYY.MM.DD

ISSUE 7

YYYY.MM.DD

ISSUE 6

YYYY.MM.DD

ISSUE 5

YYYY.MM.DD

ISSUE 4

YYYY.MM.DD

ISSUE 3

YYYY.MM.DD

ISSUE 2

YYYY.MM.DD

ISSUE 1

2019.04.11

COVER SHEET

INTERIOR DESIGN SHEET #

SHEET TITLE

ID 1.0

LEVEL 1 FURNITURE PLAN

ID 1.1

LEVEL 2 FURNITURE PLAN

ID 1.2

LEVEL 3 FURNITURE PLAN

ID 2.0

CAFE & EXHIBITION FURNITURE PLAN

ID 3.0

CAFE & EXHIBITION CONSTRUCTION PLAN

ID 4.0

CAFE & EXHIBITION REFLECTED CEILING FINISH PLAN

ID 5.0

CAFE & EXHIBITION LIGHTING PLAN

ID 6.0

CAFE & EXHIBITION POWER AND DATA PLAN

ID 7.0

CAFE & EXHIBITION FINISH PLAN

ID 8.0

CAFE & EXHIBITION ELEVATIONS

ID 8.1

CAFE & EXHIBITION ELEVATIONS

ID 8.2

CAFE & EXHIBITION ELEVATIONS

ID 8.3

CAFE & EXHIBITION ELEVATIONS

ID 8.4

CAFE & EXHIBITION ELEVATIONS

ID 8.5

CAFE & EXHIBITION ELEVATIONS

ID 9.0

BAR PLAN / ELEVATIONS

ID 9.1

BAR ELEVATIONS

ID 9.2

BANQUETTE PLAN / ELEVATIONS

ID 9.3

BAR TABLE AND TOUCHSCREEN PLAN / ELEV

ID 10.0

BAR SECTIONS

ID 10.1

BANQUETTE / TOUCHSCREEN / BAR TABLE SECTIONS

COPYRIGHT: This drawing/design is and at all times remains the exclusive property of Lucine Design interior design inc and cannot be used or duplicated without written consent. This drawing shall not be scaled. The general contractor shall verify all dimensions, datums and levels prior to commencement of work. Any errors and omissions are to be reported to the designer immediately.

REVISION: DATE

NO.

DESCRIPTION

18.5 (200)

2

KITCHEN

30 (325)

1.2 (dining, beverage and cafeteria space)

25

16

RADIO ROOM

4 (44)

1.85 (reading or writing rooms or lounges)

2

1

13. EXIT LIGHT REQUIREMENT WITH ILLUMINATION LEVELS: REFER TO BCBC 3.2.7.1. AN EXIT SHALL PROVIDE ILLUMINATION WITH AN AVERAGE LEVEL NOT LESS THAN 50 LX AT FLOOR OR TREAD LEVEL 14. LIGHTING FOR PUBLIC AREAS: REFER TO TABLE 9.34.2.7. STORAGE ROOMS WITH 50LX MINIMUM ILLUMINATION. PUBLIC WATER CLOSET ROOMS WITH 100LX MINIMUM ILLUMINATION. RECREATION ROOMS WITH 100LX MINIMUM ILLUMINATION. 15. EXIT CAPACITY & EXIT CAPACITY MULTIPLICATION FACTOR: REFER TO BCBC 3.4.3.2. (1) (B) THE MINIMUM AGGREGATE REQUIRED WIDTH OF EXITS SERVING FLOOR AREAS INTENDED FOR ASSEMBLY OCCUPANCIES, RESIDENTIAL OCCUPANCIES, BUSINESS AND PERSONAL SERVICES OCCUPANCIES, MERCANTILE OCCUPANCIES, AND INDUSTRIAL OCCUPANCIES SHALL BE DETERMINED BY MULTIPLYING THE OCCUPANT LOAD OF THE AREA SERVED BY 8MM PER PERSON. NUMBER OF PEOPLE X MULTIPLICATION FACTOR: 792 PERSONS X 8 MM / PERSON = 6336 MM EXIT CAPACITY: 6336/1066 (42”) = 5.94 DOORS (6 DOORS)

LUCINE LU T:778-999-3131 E:Lucine.lu@hotmail.com

16. TRAVEL DISTANCE REQUIREMENTS: REFER TO BCBC 3.4.2.4. AND BCBC 3.4.2.5. (C) REQUIRED: TRAVEL DISTANCE TO THE EXIT SHOULD BE LESS THAN 45 M PROVIDED: TRAVEL DISTANCE TO THE EXIT SHOULD BE LESS THAN 29.3 M 17. DISTANCES BETWEEN EXITS (INCLUDE MINIMUM DISTANCE): REFER TO BCBC 3.4.2.3. REQUIRED: ONE HALF THE MAXIMUM DIAGONAL OF THE FLOOR AREA BUT NOT LESS THAN 9 M PROVIDED: LESS THAN 26 M, MORE THAN 9 M 18. NUMBER OF EXITS: REFER TO BCBC 3.4.2.1. (1) EACH FLOOR AREA HAS 2 EXITS MINIMUM REQUIRED: 6 EXITS PROVIDED: 13 EXITS 19. MINIMUM WIDTHS OF EXITS: REFER TO BCBC 3.4.3.2. (8) EXIT CORRIDORS AND PASSAGEWAYS TO BE 1100 MM MINIMUM. STAIRS TO BE 1100 MM MINIMUM. DOORWAYS TO BE 800 MM MINIMUM. 20. TOTAL WIDTH OF EXITS:REFER TO BCBC 3.4.3.2.(8) REQUIRED: 1066 mm / EXIT X 6 = 6396 mm (251.8") PROVIDED: 1066 mm / EXIT X 13 = 13858 mm (545.5") 21. BARRIER FREE DESIGN CONFORMANCE REQUIREMENTS: REQUIREMENTS TO BE IN CONFORMANCE WITH BCBC SECTION 3.7 AND 3.8.

CLIENT INFORMATION:

BCIT 3700 WILLINGDON AVENUE BURNABY, BC CANADA V5G 3H2 604-434-0000 PROJECT INFORMATION:

SAFEHUB 1561 QUEBEC STREET VANCOUVER, BC CANADA V6A 0G5 DRAWING NAME:

COVER SHEET

GUEST PARKING 78'-8"

SIDEWALK

EET

FIREMAN TRAINING DRILLS AREA

129'-6"

R SWITCHMEN ST

15'-1"

30'-1"

27'-7"

95 °

STAFF PARKING FIRE TRUCK TEMPORARY PARKING

SIDEWALK

YYYY.MM.DD

ISSUE 10

10. MINIMUM FIRE RESISTANCE RATING REQUIRED: REFER TO BCBC 3.2.2.24. FLOOR ASSEMBLIES SHALL BE FIRE SEPARATIONS WITH A FIRE-RESISTANCE RATING NOT LESS THAN 1 H. MEZZANINES SHALL HAVE A FIRE-RESISTANCE RATING NOT LESS THAN 1 H.

AREA SQ. M (SQ. FT.)

DOOR NUMBER

#

LEVEL 3 OCCUPANT LOAD: 319 319-10=309/2=154.5 154.5 MALES, 154.5 FEMALES WATER CLOSETS: MALE: 4 FEMALE: 7 UNISEX: 1 LAVATORIES: MALE: 2 FEMALE: 4 UNISEX: 1

ROOM NAME

SYMBOL LEGEND

#

LEVEL 2 OCCUPANT LOAD: 87 87-10=77/2=38.5 38.5 MALES, 38.5 FEMALES WATER CLOSETS: MALE: 1 FEMALE: 2 UNISEX: 1 LAVATORIES: MALE: 1 FEMALE: 1 UNISEX: 1

TOTAL WATER CLOSETS: 29 TOTAL LAVATORIES: 17

8. OCCUPANCY LOAD TABLE WITH ROOM SIZES: REFER TO BCBC 3.1.17.1

VANCOUVER DISTRICT

#

LEVEL 1 OCCUPANT LOAD: 386 386-10=376/2=188 188 MALES AND 188 FEMALES WATER CLOSETS: MALE: 4 FEMALE: 8 UNISEX: 1 LAVATORIES: MALE: 2 FEMALE: 4 UNISEX: 1

CS

YYYY.MM.DD

ISSUE 11

7. GOVERNING CODE SECTION: REFER TO BCBC 3.2.2.24

DISTRICT LOT: FC

#

9. WASHROOMS & HEALTH REQUIREMENTS: REFER TO BCBC 3.7.2.2. WATER CLOSETS REFER TO BCBC 3.7.2.2.A LAVATORIES REFER TO BCBC 3.7.2.3.

2. PROJECT GROSS AREA: 1207.73 S.M.

ACC ADD.

FEC

LEGAL DESCRIPTION

REQUESTED MAXIMUM TOTAL OCCUPANT LOAD: 792

1. GROSS BUILDING AREA: 2322.57 S.M., 3 STOREY BUILDING AND BUILDING HEIGHT TO BE 13.3 M

STANDARD ABBREVIATIONS

CLIENT COMPANY: BRITISH COLUMBIA INSTITUTE OF TECHNOLOGY ADDRESS: 3700 WILLINGDON AVE. BURNABY, BC, CANADA V5G 3H2 T: 604.432.8612

BUILDING CODE ANALYSIS (BASED ON BCBC 2012)

ISSUE 12

DRAWN BY:

LUCINE LU

CHECKED BY: KATHRYN LANGE

SIDEWALK

SIDEWALK

152'-9"

SITE PLAN SCALE: 1/64" = 1'-0"

DATE:

11.04.2019

SCALE:

AS NOTED

FILE NAME:

COMMERCIAL

FILE NUMBER: 01

QUEBEC STREET

2 CS

ROBIN MCINTOSH

85 °

OUTDOOR FEATURE DESIGN / SEATING

3 CS

KEY PLAN SCALE: 1/32" = 1'-0"

DRAWING NUMBER:

OF22