TENNIS COURT LIGHTING
OUTDOOR TENNIS COURT LIGHTING
Artificial lighting to sporting facilities needs to be carefully planned in order to meet the high levels of illumination and uniformity required by each sport, as well as avoid glare and provide an energy efficient solution. Each sport has its own specific lighting requirements which are determined by the pace of play, size and speed of the ball, spectator location, and nature of the sport.
Up until recently, particularly for outdoor sporting facilities, it was only metal halide flood lights that could handle this task. The high output lamps could deliver the best luminous efficacy, whilst also provide appropriate levels of colour temperature and colour rendering for this specialist area of lighting.
Advancements in LED technology mean that it is now possible to substitute metal halide fittings for LED’s with an equivalent lumen package that consume only half of the power of their traditional counterparts. This is in addition to all of the other benefits of LED’s over HIT lamps such as reduced maintenance intervals, instantaneous operation, and colour stability.
1
With the above in mind, the following examples illustrate the advantages of contemporary LED area lighting over conventional Metal Halide when applied to Outdoor Tennis Court Lighting.
Tennis is a fast paced sport which demands high levels of visual acuity. Good contrast between the ball and the vertical surrounds are important, however the drop off in illumination levels beyond the boundary lines should not to be too stark as players are also active in those areas.
In addition to the court itself being uniformly lit, the ball should also have a consistent level of illumination for players to better judge its velocity and trajectory during play.
Luminaires should be mounted at a sufficient height in order to mitigate glare.
2
Lighting specifications for outdoor courts
Class I
Top-level national and international competitions (non-televised) with requirements for spectators with potentially long viewing distances.
Class II
Mid-level competition, such as regional or local club tournaments. This generally involves medium-sized numbers of spectators with average viewing distances. High-level training may also be included in this class.
Class III
Low-level competition, such as local or small club tournaments. This does not usually involve spectators. General training, school sportsand recreational activities also fall into this class.
Twin court systems
Single court systems
3 Recommended lighting levels
Residential Standard 4 x Environ 1000 Standard 10 x Environ 1000 9 x Poles Deluxe 12 x Environ 1000 9 x Poles Based on the requirements set out in BS EN 12193:2007 and shown in the table referenced, there are three levels of classification for outdoor tennis courts: * Table from the European Standard for Sports Lighting EN12193
Horizontal illuminance Uniformity of illuminance Glare Lamp colour temperature Lamp colour rendering Eh average (lux) Emix / Eh ave GR (K) R a Class l > 500* > 0.7 < 50 > 4000 > 80 Class ll > 300* > 0.7 < 50 > 4000 > 65 Class lll > 200* > 0.6 < 55 > 2000 > 20 16.5 m 7 m 7 m Mounting Height 7.0 m 33 m 11 m 11 m Mounting Height 7.0 m 33 m 11 m 11 m Mounting Height 7.0 m 33 m
Lighting calculations
The following DIALux illuminance calculations analyse a standard metal halide flood light solution against two contemporary LED flood light options, and how they compare side by side when lighting single and twin outdoor tennis courts.
Whilst traditional (metal halide) lighting installations would require costly additional hardware in order to accommodate staged lighting between the different classes, LED flood lights are better equipped for this scenario allowing for more flexibility (professional, amateur, recreational level of play) and energy savings.
4
5 Metal halide solution SINGLE COURT - Lighting level class III TWIN COURT - Lighting level class II TWIN COURT - Lighting level class III Six of Single 1050W HIT = 6,300W E avg = 355 lx Emin/Eavg = 0.40 Emin = 143 lx E max = 471 lx MUSTANG 34 MS-93051 Six of Single 1050W HIT = 6,300W Three of Dual 1050W HIT = 6,300W E avg = 318 lx Emin/Eavg = 0.38 Emin = 120 lx E max = 738 lx Six of Single 1050W HIT = 6,300W Three of Dual 1050W HIT = 6,300W E avg = 318 lx Emin/Eavg = 0.38 Emin = 120 lx E max = 738 lx
Ten
6
SINGLE
COURT - Lighting level class III TWIN COURT - Lighting level class II TWIN COURT - Lighting level class III BILLUND 3 BIU-90025 Six of Dual 275W LED = 3,300W E avg = 318 lx Emin/Eavg = 0.62 Emin = 197 lx E max = 396 lx LED solution Ten of Dual 275W LED = 5,500W Nine poles total, centre pole with four heads E avg = 300 lx Emin/Eavg = 0.71 Emin = 214 lx E max = 494 lx
of Dual 275W LED = 5,500W Nine poles total, centre pole with four heads E avg = 300 lx Emin/Eavg = 0.71 Emin = 214 lx E max = 494 lx
7 Nine of Dual 210W LED = 3,780W E avg = 211 lx Emin/Eavg = 0.72 Emin = 152 lx E max = 316 lx
SINGLE
COURT - Lighting level class III TWIN COURT - Lighting level class II TWIN COURT - Lighting level class III STEAMER 12 SE-90032 LED solution Nine of Dual 210W LED = 3,780W E avg = 211 lx Emin/Eavg = 0.72 Emin = 152 lx E max = 316 lx Six of Dual 210W LED = 2,520W E avg = 266 lx Emin/Eavg = 0.62 Emin = 164 lx E max = 363 lx
Comparing the various solutions and their respective power consumption, the energy savings that can be made by switching from Metal Halide to LED flood lights quickly become apparent.
LIGMAN MUSTANG 34 MS-93051 6 of 1050W HIT 6,300W
LIGMAN BILLUND 3 BIU-90025 12 of 275W LED 3,300W Consumes 48% less power than HIT equivalent
LIGMAN STEAMER 12 SE-90032 12 of 210W LED 2,520W Consumes 60% less power than HIT equivalent
LIGMAN MUSTANG 34 MS-93051 12 of 1050W HIT 12,600W
LIGMAN BILLUND 3 BIU-90025 20 of 275W LED 5,500W Consumes 56% less power than HIT equivalent
LIGMAN STEAMER 12 SE-90032 18 of 210W LED 3,780W Consumes 70% less power than HIT equivalent
When taking into account the additional benefits that LED lamps provide – such as longer life, colour stability, sophisticated control options, instantaneous operation, and optimised beam distribution – and thanks to the availability of high output modules, this advanced lighting technology can now be embraced by the specialist field of sports lighting.
8
9 BILLUNDStreet & area lighting luminaires Innovative, high-performance, sustainable street and area lighting family. Future proof solutions offering flexible glarecontrolled optic options, high efficacies, robust environmental protection and a slim attractive profile colour code - 03 - 05 - 06 White Matt Silver Bronze RAL 9003 RAL 9006 RAL 6014 Special finishes upon request - SU03 - SU04 - SW01 - SW02 - SW03 Softscape Stone Corten Oak Walnut Pine Urban Urban Woodland Woodland Woodland
Luminaire Structure
- Die-cast
Thermal
Durable
High-efficiency
High-efficiency
Clear
Feature symbols
10
aluminium housing - Pre-treated before powder coating ensuring high corrosion resistance -
heat dissipation body - Stainless steel fasteners in grade 316 -
silicone rubber gasket -
polycarbonate lens -
PMMA lens -
toughened glass - Surge protection 10kV - Constant lumen output (CLO) and Night-time dimming options T5
Light
symbols M W ME T1 T2 T3 T4 www.ligman.com/billund
11 Product code guide BIU-90025 - T2 - 8030 - SC60 - 01 Spigot CRI & CCT Optic Luminaire colour Spigot SC60 – Dia. 60mm. SC76 – Dia. 76mm. Colour Rendering Index & Colour Temperature 8030 – 3000K CRI80 8040 – 4000K CRI80 Dimming Type ND – Non dimmable DI – 1-10V dimming DA – DALI dimming Luminaire colour 01 – Black 02 – Dark Grey 03 – White 05 – Matt Silver 06 – Bronze BILLUND Street & area lighting luminaires Product code Lamp Power Lumen EEC Weight Optic CRI & CCT Dimming type T1 T2 T3 T4 T5 Large BILLUND 3 BIU-90025 2 x 72 LED 275 W 33136 - 41464 lm A++ 15.1 kg 138°x125° 140°x63° 133°x66° 111°x65° 92°x121° 8030 | 8040 ND | DI | DA 10° 10° 10° 15° 15° 15° 15° 15° 15° Spigot SC42-48 Spigot SC60 Spigot SC76 Spigot SC42-48 Spigot SC60 Spigot SC60 Spigot SC76 99 99 10° 10° 10° 110 Ø60-76 950 455 118 118 15° 15° 15° 137 865 125 125 251 15° 15° 15° BILLUND 1 BILLUND BILLUND 2 BILLUND 3 Spigot SC42-48 Spigot SC60 Spigot SC76 Spigot SC42-48 Spigot SC60 Spigot SC60 Spigot SC76 Ø80 Ø80 Ø100 128 10° 10° 10° 212 381 455 118 118 131 245 15° 15° 15° 137 125 125 251 15° 15° 15° Spigot SC42-48 Spigot SC60 Spigot SC76 Spigot SC42-48 Spigot SC60 Spigot SC60 Spigot SC76 Ø80 Ø100 BILLUND 3 * Please refer to POLES section for different pole options. 1 m 1.5 m 2 m 1.70 m 2.5 m 3 m 3.5 m 4 m 4.5 m 5 m 5.5 m 6 m 4 m - 6 m
Column-mounted
EUROPE
HEADQUARTERS
CZECH REPUBLIC
LIGMAN Europe s.r.o. VGP Park Ústí nad Labem, P2, 40317, Přestanov 120 Tel: +420 477 071 500 sales.cz@ligman.com
RUSSIA
Люмен Центр OOO TC Möbel Expo, Nakhimovskiy Prospekt 24, Moscow 117218, Russia
Tel: +7 (915) 182 33 00 info@lumencentr.ru
FINLAND
LIGMAN Lighting Co., Ltd. Plaza Business Park PILKE, Äyritie 16 01510, Vantaa Tel: +358 440 428296 sales.fi@ligman.com
FRANCE
LIGMAN SAS FRANCE. 59 Allée Jean Jaurès CS 21531, 31015, Toulouse Tel: +33 6 79 19 27 76 sales.fr@ligman.com
UNITED KINGDOM
DW Windsor Co., Ltd. Pindar Road, Hoddesdon, Hertfordshire EN11 0DX ligman@dwwindsor.uk
SPAIN
LIGMAN Spain S.L. Ronda Sant Pere, 52 Atico, 08010 Barcelona
Tel: +34 659 19 40 17 sales.es@ligman.com
SWEDEN
LIGMAN Sweden Tideliusgatan 35, Södermalm Stockholm
Tel: +46 709 514 156 thomas.ni@ligman.com
NORTH AMERICA
HEADQUARTERS
UNITED STATES
LIGMAN Lighting USA Inc. 7144 NW Progress Court, Hillsboro 97124, Oregon
Tel: +1 503 645 0500 info@ligmanlightingusa.com www.ligmanlightingusa.com
MIDDLE EAST AND AFRICA
HEADQUARTERS
UNITED ARAB EMIRATES
LIGMAN ME (FZE)
PO Box 121064, Q3-031 Sharjah Airport International Free (SAIF) Zone, U.A.E. Sharjah Tel: +971 6557 8950 sales.me@ligman.com
ASIA PACIFIC
HEADQUARTERS
THAILAND
Lighting Experience Center
The LANTERN Building 2300 Rama 9 Rd, Suan Luang, Suan Luang, 10250 Bangkok Thailand
Tel: +66 2 321 8211 info@ligman.com
INDONESIA
PT. LIGMAN Lighting Indonesia Jl. Raya Pos Pengumben No.11 Srengseng, Jakarta Barat 11630 Tel: +62 8787 719 1488 sales.id@ligman.com
PHILIPPINES
LIGMAN Lighting Philippines. Inc. Unit 2STY-2BR-3A, Gomega 1 Condominium, P. Martinez St., Barangay Daang Bakal, Mandaluyong City. 1550 Tel: +63 02 7907 8407 +63 02 8688 9426 sales.ph@ligman.com
HONGKONG
Lumen Design Lighting Co., Ltd. Unit 4112, Tower 2, Metroplaza, 223 Hing Fong Road, Kwai Chung, N.T Tel: +852 2410 1411 info-hongkong@lumendesign.com.hk
KOREA
LIGMAN Korea 362 Heungan dae-ro,Dongan-Gu, Annyang-Ci, Kyungi-do, Korea. (303 Wharang Bldg 303, Pyoungchon-Dong) 14064, Pyoungchon-Dong Tel: +82 31 458 0941 ligmkorea@gmail.com
SINGAPORE
LIGMAN Pte Ltd. 33 Ubi Avenue 3 #01-11 408868, Vertex Tel: +65 6288 7379 sales.sg@ligman.com
AUSTRALIA
Efficient Lighting Systems Pty. Ltd. 39 Tinning Street, VIC, 3056, Brunswick Tel: +61 3 9222 5522 sales@elslighting.com.au
INDIA
LIGMAN Lighting Co., Ltd. 703, Tower-B, The Ithum, A-40, Sector-62 201301, Noida
Tel: +91 951 959 6161 +91 120 427 3974 sales.in@ligman.com
Social
/ligmangroup
Ligman reserves the right to change any specification without pior notification.
Publication on: 2021/4 FM-MA-16/99
Updated: 20/05/21
© Copyright Ligman Lighting Co.,Ltd. All rights reserved.
www.ligman.com