98
Kardioanestezie a perioperační péče v kardiochirurgii
10. Gallagher JD, Moore RA, McNicholas KW et al. Comparison of radial and femoral arterial blood pressures in children following cardiopulmonary bypass. J Clin Monit 1985, 1:168. 11. Boutros A, Albert S. Effect of the dynamic response of transducer-tubing system on accuracy of direct blood pressure measurement. Cri Care Med 1983, 11:124–127. 12. Zaidi NA, Khan M, Naqvi HI, Kamal RS. Cerebral infarct following central venous cannulation. Anaesthesia 1998, 53:186–191. 13. Swan HJC, Ganz W, Forrester JS et al. Catheterization of the heart in man with the use of a flow-directed baloon-tipped catheter. N Engl J Med 1970, 283:447–451. 14. Shah MR, Hasselblad V, Stevenson LW, Binanay C, O’Connor CM, Sopko G, Califf RM. Impact of the pulmonary artery catheter in critically ill patients: Meta-analysis of randomized clinical trials. JAMA 2005, 294:1664–1670. 15. Kearney TJ, Slabot mm. Pulmonary Artery rupture associated with the Swan-Ganz catheter. Chest 1995, 108:1349–1352. 16. Forrester JS, Ganz W, Diamond G et al. Thermodilution cardiac output determination with a single flow-directed catheter. Am Heart J 1972, 83:306. 17. Yelderman M. Continuous measurement of cardiac output with the use of stochastic system identification techniques. J Clin Monit 1990, 6:322–332. 18. Lang RM, Borow KM, Neumann A, Janzen D. Systemic vascular resistance: an unreliable index of left ventricular afterload. Circulation 1986, 74:1114–1123. 19. Gorback ms. Problems associated with the determination of pulmonary vascular resistance. J Clin Monit 1990, 6:118–127. 20. Erlanger NWF, Hooker DR. An experimental study of blood pressure and of pulsepressure in man. Johns Hopkins Hosp Rep 1994, 12:145–378. 21. Huggins RA, Smith EL, Sinclair MA. Comparison of cardiac output by the direct Fick and pressure pulse contour methods in the open/chest dog. Am J Physiol 1949, 159:385–388. 22. Langewouters GJ, Wesseling KH, Goedhard WJ. The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model. J Biomech 1985, 18:613–620. 23. Manecke GR. Edwards FloTrac sensor and Vigileo monitor easy, accurate, reliable cardiac output assessement using the arterial pulse wave. Expert Rev Med Devices 2005, 2(5):523–526. 24. Reuter DA, Kirchner A, Felbinger TW, Weiss FC, Kilger E, Lamm P, Goetz AE. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patiens with reduced cardiac function. Crit Care Med 2003, 31(5):1399–1403. 25. Rödig et al. Continuous cardiac output measurement: pulse contour versus thermodilution techniques in cardiac surgical patiens. Br J Anaesth 1999, 50:525. 26. Jansen et al. A comparison of cardiac output derived from the arterial pressure wave against termodilution in cardiac surgery patiens. Br J Anaesth 2001, 87:212. 27. Kharasch ED, Sivarajan M. Gastroesophageal perforation after intraoperative transesophageal echocardiography. Anaesthesiology 1996, 12:314–316. 28. Shanewise JS, Cheung AT, Aronson S et al. ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: Recommendations of the American Society of Echocardiography Council for intraoperative echocardiography and the Society of Cardiovascular Anaesthesiologists task
Ukázka elektronické knihy, UID: KOS180908