➱Vendor: EMC
➱Exam Code: DES-4122
➱Exam Name: Specialist - Implementation Engineer, PowerEdge Exam

New Updated Questions from Pdf4test (Updated in Mar, 2023)
Visit Pdf4test and Download Full Version DES-4122 Exam Dumps

NEW QUESTION # 18
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad
1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?
A. iDRAC Datacenter license is installed.
B. iDRAC dedicated NIC port is cabled and the link light is green
C. iDRAC Enterprise license is installed
D. Ethernet port LOM1 is cabled and the link light is green.
Answer: B
NEW QUESTION # 19
A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?
https://pdf4test.com/DES-4122-dump-torrent.html
Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
A. The server has been powered down
B. There are more than the maximum number of active sessions
C. Operating system not installed on remote server
D. The Virtual Console is disabled
Answer: A
NEW QUESTION # 20
A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:

* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed How can the technician upgrade the license?

A. The license cannot be upgraded because the user will not allow the server to be powered on
B. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down
C. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
D. The license cannot be upgraded on a single PSU system
Answer: B

NEW QUESTION # 21
Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?

A. Android devices only
B. iOS devices only
C. iOS, Android, and Windows Phone devices
D. iOS and Android devices only
Answer: D
NEW QUESTION # 22
What is the minimum number of components, beside the system board, required to POST?

A. 1 PSU and 1 CPU only
B. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
C. 1 PSU, 1 DIMM, and 1 CPU only
D. PSUs, CPUs, and DIMMs as configured in BIOS



Answer: C
NEW QUESTION # 23
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
C. Option C
D. Option A
Answer: C
NEW QUESTION # 24
Match each RAID level to its characteristic.
Answer:
Explanation:
NEW QUESTION # 25
You must configure a BOSS card with 2 x 120GB drives for a Dell EMC PowerEdge server. What is the only supported mode?


A. RAID 0
B. RAID 1
C. Non-RAID Mirroring
D. RAID 5

Answer: B
NEW QUESTION # 26
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server? A)
A. Option B


B. Option D



C. Option C
D. Option A
Answer: C
NEW QUESTION # 27
Refer to the exhibit.
Answer:


Explanation:

NEW QUESTION # 28
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?
A. 256 GB
B. 64 GB
C. 128 GB
D. 512 GB
Answer: C
NEW QUESTION # 29
How can a technician know whether IDRAC9 System Lockdown mode is enabled?


A. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots
B. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
C. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
D. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
Answer: B
NEW QUESTION # 30
You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.
Answer:
Explanation:
Send us your suggestion for this simulation task.
NEW QUESTION # 31
What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?
A. All GPU cards must be of the same type but can be a different model
B. All GPU cards must be installed at the same time
C. All GPU cards must be installed on the same riser card.
D. All GPU cards must be of the same type and model
Answer: D
NEW QUESTION # 32
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?


A. 12G
B. 13G
C. 14G
D. 11G
Answer: B
NEW QUESTION # 33 ......