KATIE GUILLEN INTERIOR DESIGN
GENERAL PROJECT NOTES
PROJECT DATA
VIRGINIA TECH
COLLEGE OF ARCHITECTURE + DESIGN
222 BURRUSS HALL, BLACKSBURG, VA 24060
1. THE GENERAL CONTRACT DOCUMENTS ARE THE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. 2.
"INSTALL" MEANS SUPPLIED BY OTHERS, TO BE INSTALLED BY CONTRACTOR.
3.
"PROVIDE MEANS FURNISH AND INSTALL COMPLETE AND IN PLACE.
4.
"TYPICAL" MEANS IDENTICAL FOR CONDITIONS NOTED.
PROJECT DESCRIPTION: THIS PROJECT IS A PARTIAL RENOVATION OF THE SECOND FLOOR AT THE NORTH SIDE OF BURRUSS HALL. THERE IS NO CHANGE OF USE, INCREASE IN AREA, OR ACTIVITY FUNCTIONS. APPLICABLE CODES AND REFERENCE STANDARDS: INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) NATIONAL ELECTRIC CODE (NEC) AMERICANS WITH DISABILITIES ACT (ADA)
BURRUSS OPEN OFFICE
5. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. VERIFY DIMENSIONS WITH FIELD DIMENSIONS, IF DISCREPANCIES ARE DISCOVERED BETWEEN INDIVIDUAL DRAWINGS, CONTACT THE DESIGNER FOR RESOLUTION BEFORE PROCEEDING.
USE GROUP CLASSIFICATION (EXISTING SPACE): E (EDUCATION) A (ASSEMBLY)
6. HORIZONTAL DIMENSIONS INDICATED ARE TO/FROM FINISHED FACE OF CONSTRUCTION EXPECT WHEN NOTED AS CENTERLINE (CL), DIMENSIONS ARE TO CENTERLINE OF FRAMING.
USE GROUP CLASSIFICATION (PROPOSED SPACE): A (ASSEMBLY) *NOTE: THERE IS NO CHANGE OF USE
7. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB, EXPECT WHERE NOTED TO BE FROM ABOVE FINISHED FLOOR (A.F.F.).
CONSTRUCTION TYPE: 24 NON-COMBUSTIBLE, PROJECTED
8. CUT AND FIT COMPONENTS FOR ALTERATION OF EXISTING WORK AND INSTALLATION OF NEW YORK. PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES.
OCCUPANT LOADS: EDUCATION AREAS CALCULATED AT ASSEMBLY AREAS CALCULATED AT
20 SQ.FT. PER OCCUPANT 15 SQ.FT. PER OCCUPANT
9. PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REMOVED DURING PERFORMANCE OF THE WORK. FIREPROOF NEW PENETRATIONS REQUIRED BY THE WORK AND EXISTING PENETRATIONS IN EXPOSED PLENUM AREAS.
OCCUPANT LOAD: PROPOSED SPACE, SECOND FLOOR
CODE: 482
PROJECT SQUARE FOOTAGE: PROPOSED SPACE, SECOND FLOOR
9550 NET SQFT.
10. CONTRACTOR AND SUBCONTRACTORS SHALL COORDINATE THE LAYOUT AND EXACT LOCATIONS OF ALL PARTITIONS, DOORS, ELECTRICAL/TELEPHONE OUTLETS AND LIGHT SWATCHES WITH DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION.
VIRGINIA TECH
ACTUAL: 130
11. CONTRACTOR SHALL PROVIDE MANUFACTURER'S SPECIFICATIONS, INSTALLATION INSTRUCTIONS, SHOP DRAWINGS AND SAMPLES FOR REVIEW AND APPROVAL OF ALL MATERIALS AND METHODS TO BE USED PRIOR TO ORDERING OR PROCEEDING WITH THE WORK. ISSUED FOR:
12. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMEND SPECIFICATIONS AND INSTALLATION PROCEDURES. IF THESE ARE CONTRARY TO THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY THE DESIGNER, IN WRITING IMMEDIATELY, TO RESOLVE DISCREPANCIES PRIOR TO PROCEEDING. 13. CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS IN AMPLE TIME IN ORDER TO AVOID DELAYS IN CONSTRUCTION. IF AN ITEM IS FOUND TO BE UNAVAILABLE, CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY TO ALLOW DESIGNER A REASONABLE AMOUNT OF TIME TO SELECT A REASONABLE SUBSTITUTE. 14. THE FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUM, LEVEL, WITH SMOOTH, CLEAN, UNIFORM APPEARANCE WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, CRACKS, STAINS, OR DISCOLORATION. JOINTING SHALL BE TIGHT FITTING, NEAT AND WELL SCRIBED. THE FINISH WORK SHALL NOT HAVE EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS. ALL WORK SHALL HAVE THE PROVISION FOR EXPANSION CONTRACTION, AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS. 15. CONTRACTOR SHALL COMPLY WITH ALL BASE BUILDING REQUIREMENTS AND DESIGN CRITERIA. 16. ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS, ORDINANCES, LAWS, ORDERS, APPROVALS, ETC., THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL COMPLY. REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO THE CURRENT APPLICABLE EDITION PUBLICATIONS OF THE FOLLOWING (OR OTHERWISE NOTED): A. INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) B. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) C. NATIONAL ELECTRIC CODE (NEC) D. INTERNATIONAL PLUMBING CODE (IPC 2009 EDITION) E. INTERNATIONAL MECHANICAL CODE (IMC 2009 EDITION) F. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) G. AMERICANS WITH DISABILITIES ACT (ADA) H. LOCAL MUNICIPAL ORDINANCES AND AMENDMENTS TO THE CODES.
DATE:
SHEET INDEX SHEET # A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A114 A115
SHEET NAME COVER SHEET FIRE AND LIFE SAFETY PLAN EXISTING PLAN DEMOLITION PLAN PLAN ENLARGED PLAN INTERIOR SECTIONS WALL SECTIONS INTERIOR ELEVATIONS INTERIOR WALL DETAILS MILLWORK DETAILS FINISH PLAN FURNITURE PLAN POWER + DATA PLAN RCP ENLARGED RCP
Consultant Address Address Address Phone
Consultant Address Address Address Phone
Consultant Address Address Address Phone
DATE PROJECT NUMBER DRAWN BY
T O N
SITE PLAN
VICINITY MAP
BURRUSS HALL, ROOM 224A
BURRUSS HALL, ROOM 224A
VIRGINIA TECH, BLACKSBURG, VIRGINIA
TH R
AREA OF NEW CONSTRUCTION
TRUE NORTH
C JE O PR
PROJECT NORTH
CHECKED BY
COVER SHEET
A100
01 MAY 2018 2018_0001 KATIE GUILLEN M. WAGNER