DISINFECTION CABIN Clean Gate is a disinfection and sanitisation walk-through cabin for the sanitisation of objects and people in conjuction with suitably installed water based atomised biocides and/or virucide sprays delivered under high pressure through multi-nozzles. This helps to reduce or eliminate the number and species of bacteria, viruses, and parasites apparent on lifeless surfaces which can enter the the human body via the eyes, nose and mouth by touching these surfaces causing servere infections. The COVID-19 virus, which is present today on all continents and causes serious health problems, is a prime example.
CABIN FEATURES Clean Gate system is triggered through sensitive receivers located on the side walls once a person enters the activation area of the cabin. Disinfectant in the tank is transmitted to the sprayer nozzles via high pressure stainless steel pipes powered by a high pressure pump rated up to 90 bar. A non-contact thermometer is fitted to the front of the cabin which displays the temperature of person entering the cabin. Clean Gate System can be integrated into PACS software (personnel attendance control system) and thus personnel-based fever information can be recorded. A red warning light shows up on the screen will alert operatives if a temperature of over 98.6F / 38C is detected. Sensors to monitor tank disinfectant levels are fitted and audible warnings given when a low level is reached.
CABIN FEATURES Easy to install and use Easy portability High pressure fogging method Maximum surface access Input-Output Sensor Adjustable to the ground Light Control Warning System Special coated metal body Electrical installation in accordance with IP65 protection class Temperature measuring sensor and instrument panel PACS integration
WHY HIGH PRESSURE? Clean Gate is different from other disinfection cabinets on the market by its system that provides high pressure propagation. To be able to perform the disinfection process at the highest level and disinfectant to reach all points, the molecules should spread out over the maximum area. Fluid coming out of the spray nozzles with high pressure, much smaller molecules than the low and normal pressure system are given to the environment. Delivery of molecules to the environment at a minimum level provides much more contact with the surface and makes the disinfection process more successful and effective. Disinfectant molecules that can be broken down up to 5-15 microns in diameter provide maximum surface access.
USAGE AREAS Private and Official Organizations
Libraries
Police and Military Units
Schools and Universities
Hospitals
Prisons
Airports
Nursing Homes
Shopping Malls
Bus Stations
Entertainment Centers
Busy Streets and Squares
Concert Areas
Sports Complexes
INSTALLATION & USE Steps to follow for installation; 1. Once the Clean Gate is removed from all packaging, it is placed on flat ground in the desired loction. 2. Clean Gate can been position correctly with the use of the casters. 3. Once the cabin is level, the suitable disinfectant to be used is filled via the tank intake located on the top of the tank. 4. After the tank is full, the cabin electrical cable is plugged in and controlled by the ON/OFF button at the right side of the cabin. Steps to follow for use; 1. After switching on the cabin and before allowing people to pass, the operator must check that the non-contact thermometer is operational and the green sign shows up on the screen indicating normal body temperature. Should a high temperature be detected, the red sign will be seen on the screen. 2. A green sign on the screen indicates the person approaching the cabin has normal body temperature and is permitted to enter. A red sign indicates a high temperature has been recorded and the operator(s) should follow the measures put in place by their management for such an incident. 3. On entering the cabin, the cabin entry sensor is activated and the disinfection process begins. 4. The disinfection process takes 3 seconds (adjustable) and the spray nozzles will stop automatically. The person exits the other end. 5. When the level of disinfectant in the tank is low, red warning lamp on the right side of the cabin lights up. The cabin should be switched OFF and the tank refilled. 6. The ON-OFF button on the right side of the cabin is used to stop the operation of the CLEAN GATE.
TECHNICAL SPECIFICATIONS Working Environment:
Spray Time :
220x150x120 cm
10-50 C
3 sec. (Adjustable)
Working Voltage :
Fog Making Way :
Spray Efficiency:
220 V AC
High Pressure (Maksimum: 90 bar)
4500 person at full capacity
Equipment Material :
Disinfection Type :
Hydrofor :
Stainless Steel
Automatic Sensor Fogging
35 lt/min. 50 Hz 22V IPX4
Body Material :
Number of Nozzles :
High Pressure Pump :
Composite Aluminum
12
HPE-M 230 V 50 Hz Max. 90 bar
Tank Material :
Tank Capacity :
Light Weight :
Polypropylene
200 lt.
150 kg
Size
:
LED Ceiling Lamp
Electrical Control Panel
High Pressure Nozzles Stainless Steel Pipes
Emergency Button Disinfectant Level Indicator
Thermal Fever Detector
Pump Failure Indicator Manual-Auto Switch
Face Recognition
High Pressure Pump
Filling Cap Aluminum Composite Panel Disinfection Tank Disinfection Filter Non-Skid Ramp Power Input
Hydrophor