Regenerative Design in Digital Practice

Page 201

Figure 30

34

Comparison between annual energy needs of three wall types. The lava stone is the material of the oldest buildings built in the 1920s. The calculation is based on the Ladybug Tools workflow and accounts for the local microclimate interaction with the buildings (Source: [11])

32

annual energy need [kWh/m²]

+10% 30

28

+5,5%

26 +1,6%

24

22

20 light plaster

dark plaster

living wall

lava stone masonry

light plaster

dark plaster

brick masonry

light plaster

dark plaster

exterior insulation and finishing system masonry

october 15th, 14:00 15th october 2.00 pm light plaster

light plaster

Figure 31 dark plaster

Comparison between UTCI values for dark and light plaster applied on the existing lava stone masonry in April and October (Source: [11])

dark plaster

lava stone

lava stone masonry masonry

utci (°C) 25.00< 24.50 24.00 23.50 23.00

brick brick masonry masonry

22.50 22.00 21.50 21.00 20.50

exterior insulation exterior and finishing insulation system and finishing masonry system masonry

194

REGENERATIVE DESIGN IN DIGITAL PRACTICE

20.00 19.50 19.00 18.50 <18.00


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.