

LET’s TALK DCI M ABOU T


Security & Environmental Monitoring


• DOOR ACCESS, CCTV, THERMAL AND HUMIDITY MAPPING



Capacity Tracking & Planning


RACK CAPACITY AND GROUPING


Capacity Tracking & Planning

• CUSTOMIZED DEVICE TYPE VIEW– RACK VIEW


Capacity
Tracking & • TREND CHART; PREDICT ANALYSIS



Visual Capacity Optimization
Manager
Sample Integrations







Wireless Tag/Sensor
IP Camera

Intelligent Power Monitoring (PX4 Rack PDU)
HIGH DENSITY OUTLET TECHNOLOGY (HDOT)


High Density Outlet Technology design that removes unnecessary outlet molding to provide space for more outlets in a PDU for increased rack density.
HDOT and Cx Outlet

• Hybrid C13 and C19 outlet accommodating both C20 and C14 power cables in a single flexible
RamLock Mechanical Locking


• Intuitive outlet and power cord locking system.
• Promotes input power cord accessibility to ease deployments.
• Flexible infeed cord design that promotes input power cord accessibility, reduces cord strain, simplifies PDU order specification, and extends the PDU’s power cord lifespan.

The 45-Degree Angled Infeed

iX Controller


Center of intelligence of the PX4, that houses computing, display, and connectivity ports.
Advanced Power Quality Monitoring and Metrics

Allows you to proactively troubleshoot sources of power issues and optimize for PUE, CUE, and more.
Total Harmonic Distortion

Measures how much your electrical load distorts your facility's power.

Circuit Breaker Trip Forensics with Waveform Capture

Determine which outlet and corresponding device cause a circuit breaker to trip.

RECAP


Thank You
COMMENT SLIDE 1
DCIM is Remote monitoring and management software that provides you with valuable information to make better business decisions It is also HTML5based platform features capabilities designed to reduce data center operational expenses, improve system and application reliability and mitigate risk through data analysis
COMMENT SLIDE 2

spot and over-cooling
3D renderings at all levels of the data center as well as across the enterprise (power, space, environment, IT networking, virtualization) and identify problems for a wide array of IT assets including physical servers, VM hosts, VM guests, switches, rack PDUs, UPS and large facility dev 2. Environmental monitoring Create real-time thermal imaging profiles of your environment using temperature, humidity, leak detection, Door closure and air pressure data

COMMENT SLIDE 3
The beauty of VCOM is it has a Capacity Tracking and Planning
Utilize the "what-if" scenarios to understand current usage to ensure capacity is present for upcoming projects you can plot a schedule and plan your rack distribution and groupings ahead of time
- It can also be use as inventory , you can put all the serials and information of your servers
- You can also have a monitoring view of your rack capacities.
COMMENT SLIDE 4
- It also has a dashboard where you can customized device type view and Rack view
COMMENT SLIDE 5
- Examine multilevel reports, role-based dashboards, KPI tracking, trending and predictive analytics
COMMENT SLIDE 6
Any brand can be integrate to VCOM as long there is a network protocol such SNMP, Modbus and Bacnet
Multitenancy -
Support more than one customer/user type by presenting seperate anddistict data that pertains solely to each tenant

COMMENT SLIDE 7
DMM & safety tool (insert header)
COMMENT SLIDE 8
Engineer and patented to eliminate the molding around an individual outlet and uses module to fit more outlet into same space
HDOT Outlet requires less space than standard PDU outlets.
COMMENT SLIDE 9
It creates a hybrid IE C19 outlet that can accommodate C20 and C14 power cables without additional parts or adapters
Rugged and high-strength outlet and cord locking system that ensuresC14 and C20 plugs to your PDU without requiring special cables, sleeves or adapters
COMMENT SLIDE 10
Wherever you feed your cabinet’s branch circuit power, The PX4’s angled infeed creates a one-size-fits-all solution that allows you to position the PDU where needed, Simplifying your deployments while saving time and money.
COMMENT SLIDE 11

Ix Controller fully hot-swappable; it enables live replacement with no power interruption to connected equipment. It's the most powerful, reliable, scalable, secure, and easy-to-use controller platform. The PX4 offers the most complete and accurate set of power quality monitoring and metrics like total harmonic distortion, Reactive power, phase angle, displacement power factor, apparent energy, and inrush current measurements.
COMMENT SLIDE 12
You can closely monitor and visualize harmonic events like voltage dips and swells, crest factor, and much more. When coupled with Waveform Capture, you have intuitive visualizations of the power being fedto the PDU or distributed to the PDU's outlets.
Having this capability at the Rack PDU helps you to ensure your data center’s rack power is running efficiently
When an overload event occurs and a circuit breaker is tripped, You can identify the exact outlet that caused the circuit breaker to trip and visualize the situation via the PX4’s onboard Waveform Capture capability.
Circuit Breaker Forensics, used with Outlet Power On Prevention, allows you to restore power to other devices faster while isolating defective equipment for maintenance.