Rinker Residence CD Set with Nava Companies

Page 1

ABBREVIATIONS

3'-0" Min 1'-6" 1'-6"

1. General: all work to be completed in accordance with the new york city building code, article 19, and regulations of all other agenies having jurisdiction. 2. Means of egress: all existing means of egress for tenants of the building to be maintained clear and free of all obstructions, such as building materials, tools, etc. 3. Fire safety: a. All building materials which are stored at the site or any area of the building are to be stored in a locked area. access to the area to be controlled by the owner, or the general contractor. b. All materials to be stored in a orderly fashion. c. All flammable materials to be kept tightly sealed in their respective manutacturers' containers. such materials are to be kept away from heat. d. All flammable materials to be used and stored in an adequately ventilated space. e. All electrical power to be shut off where there are exposed conduits. f. All electrical power in the construction area to be shut off after working hours. g. Contractor, at all times, to ensure there is no natural gas leakage in the buildings, or any flammable gas to be used during construction. 4. Dust control: a. Debris, dirt and dust to be kept to a minimum and confined to the immediate constuction area. b. Contractor to isolate construction area from occupied building area by means of temporary partitions or heavy weight drop cloths. c. Debris, dirt, and dust to be cleaned up and cleared from the building site periodically to avoid excessive accumulation. 5. Noise after hours: a. Construction operations will be confined to normal working hours, as stipulated in the alteration agreement. b. Contractor must obtain written permission from all affected parties to work other than regular hours. 6. Construction operations will not involve interruption of heating, water, or electrical services to other tenants. 7. Construction work will be confined to the apartment interior, and will not create dust, dirt, or other such inconveniences to the other apartment units within the building.

ZONING ANALYSIS

3'-0" Min 1'-6" 1'-6"

3'-6" Min

2'-6" Min

SIDE

SIDE

4'-8" Min

4'-8" Min

5'-6" Min

3'-0"

LAV Clear Floor Space

Clear Floor Space

BLOCK: LOT: ZONING MAP: ZONING DISTRICT:

Nava Companies

1546 7501 9A R8B

31 Union Square West, Suite 2D New York, NY 10003, USA Tel: 212.365.1052 www.navacompanies.com

Clear Floor Space

AREA CALCULATIONS 4'-0" Min

4'-0" Min

5'-0" Min

Mechanical Engineer:

5'-0" SHOWER SIZES AND CLEARANCES

CLEAR FLOOR SPACE FOR ADAPTABLE BATHROOMS

LOT AREA:

2043.4 SF N

RESIDENTIAL FLOOR AREA RATIO MAX F.A.R. MAX F.A.R.

Note: Cross hatched areas to receive blocking for securing grab bars

3.69 2043.4 x 3.69 = 7540.15 SF

3'-0" Max 1'-0"1'-0" Min Min

TP

STANDARD SYMBOLS

Structural Engineer:

INTERIOR ELEVATION 2/A00.01

19" Max 4'-0" Min

TOILET PAPER DISPENSER LOCATION

D'Antonio Consulting Engineers, P.C. 30 West Waukena Avenue Oceanside, NY 11572, USA 576.594.4284

APPROXIMATE BUILT SQUARE FOOTAGE:

(B) BACK WALL

(A) SIDE WALL

BLOCK: 1546 LOT: 7501 ZONING MAP: 9A ZONING DISTRICT: R8B

17" Min 2'-6" Min

1'-7" Min

RESIDENTIAL GROSS AREA

2'-8" Min 3'-2" Max

GENERAL NOTES:

CLEAR FLOOR SPACE AT LAVATORIES

REINFORCING AREAS FOR INSTALLATION OF GRAB BARS IN BATHROOMS

GROUND FLOOR (RESIDENTIAL UNIT 1): FIRST FLOOR (RESIDENTIAL UNIT 1): SECOND FLOOR (RESIDENTIAL UNIT 2): THIRD FLOOR (RESIDENTIAL UNIT 3):

1180 SF 1180 SF 800 SF 800 SF

TOTAL RESIDENTIAL FLOOR AREA:

3960 SF

Robert Silman Associates 32 Old Slip, 10th Floor New York, NY 10005, USA 212.420.7970

#

#

###

#

INTERIOR ELEVATION

Key Plan:

#

3

EXTERIOR ELEVATION

PROPOSED BUILDING ADDITION: X = 0"-25"

2'-1" Max

40" Max 29" Min 27" Min 9" Min

Y = 48"

2'-6"

Note: Dashed line indicates dimensional clearances of optional underlavatory enclosure

X 4'-0"

Z=X OR GREATER

GROUND FLOOR (RESIDENTIAL UNIT 1): FIRST FLOOR (RESIDENTIAL UNIT 1): SECOND FLOOR (RESIDENTIAL UNIT 2): THIRD FLOOR (RESIDENTIAL UNIT 2): FOURTH FLOOR (RESIDENTIAL UNIT 2):

1180 SF 1180 SF 800 SF 800 SF 800 SF

TOTAL RESIDENTIAL FLOOR AREA:

4760 SF

MAX ALLOWABLE RESIDENTIAL FLOOR AREA = 7540.15 SF > 4760 SF = OK

Note: X = Reach Distance, Y = Maximum Height, Z = Clear Knee Space. Z is the clear space below the obstruction, which shall be at least as deep as the reach distance

MAXIMUM FORWARD REACH OVER AN OBSTRUCTION

ROOMNAME

3

SPACE DESIGNATION

REVISION DESIGNATION

Legend:

WINDOW DESIGNATION

Notification:

LAVATORY CLEARANCES

DOOR

DOOR DESIGNATION

HEIGHT REQUIREMENTS

28" - 36"

DEMOLITION NOTES 1. Provide selective demolition work as shown and as needed for a complete and proper installation of the work. 2. Contractor to perform selective demolition in a systematic manner. Use such methods as required to complete work indicated in accordance with demolition schedule and governing regulations; comply with new york city building code and regulations of the building. 3. Remove all items necessary to accommodate the new construction. 4. Remove salvageable items as noted for reuse with care to prevent damage. Store in a protected area where directed by the owner. 5. Repair and restore all permanent materials damaged during the demolition process or other construction activity. 6. Remove debris, rubbish and other non-salvageable materials resulting from demolition operations from the site. 7. Demolish and remove all existing partitions, doors, walls, floor coverings and ceilings as noted and/or keyed. 8. Demolish and remove all plumbing lines, fixtures and equipment as noted and/or keyed. All branchwork plumbing to be removed back to the riser. 9. Demolish and remove all existng electrical, telephone and computer wiring, devices, conduits and black boxes back to existing panels as noted and/or keyed. 10. Demolish all soffits, dropped ceilings including pencil rod and chicago bar or other furring materials. 11. Demolish all electrical points, including jboxes, terminations, cabling and switch controls. 12. Demolish all recessed light fixtures, sconces, cabinetry lighting and track lighting. 13. Demolish all air conditoning equipment including condensor units, air handlers, controls, and all duct work and grills. 14. All gas branch work to be demolished back to riser. New shut off valves to be installed. 15. All water, waste and venting branch work to be demolished back to riser locations. New shutoff valves to be installed throughout.

SUGGESTED FLEXIBLE SUPPLY LINES

MIN. BASE HEIGHT MAX. BASE HEIGHT

SUGGESTED SLIP JOINT IN TAIL PIECE

REQUIRED

PROPOSED

55 FT 60 FT

55 FT

1

DRAWING LABEL Scale: SCALE: ACTUAL SIZE

COPYRIGHT NOTICE: THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SECTION 102 OF THE COPYRIGHT ACT 17 U.S.O. AS MENTIONED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS PROTECTION ACT OF 1990. THE PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK, OR BUILDING REPRESENTED CAN LEGALLY RESULT IN CESSATION OF CONSTRUCTION OR BUILDING BEING SEIZED AND/OR MONETARY COMPENSATION TO: NAVA COMPANIES LLC THIS PLAN IS SUBMITTED ONLY FOR WORK INDICATED ON THE APPLICATION SPECIFICATION SHEET. ALL OTHER MATTERS ARE NOT TO BE RELIED UPON OR TO BE CONSIDERED AS EITHER BEING APPROVED OF OR IN ACCORDANCE WITH APPLICABLE CODES.

Issue Description

Date

ISSUE

MAX BLDG. HEIGHT

2'-6" Min BEFORE REMOVAL OF CABINETS AND BASE

75 FT

55 FT NO CHANGE OF USE, OCCUPANCY AND EGRESS

4'-0" Max

28" - 36" Max

CABINETS AND BASE REMOVED AND HEIGHT ALTERNATIVES

Date

Revision

SMOKE DETECTOR/CARBON MONOXIDE NOTES

2'-6" Min CABINETS AND BASE REMOVED AND HEIGHT ALTERNATIVES

BEFORE REMOVAL OF CABINETS AND BASE

LIST OF DRAWINGS

MEP AND STRUCTURAL DRAWINGS:

RINKER RESIDENCE 344 E 84TH STREET NEW YORK, NY 10028

LOCATION OF GRAB BAR REINFORCEMENTS AND CONTROLS OF ADAPTABLE SHOWERS

GENERAL NOTES Seal & Signature: 6" Max 2'-0"

Date: 5/26/2016 Project Number:

9" 5'-0" Max Min

Drawing: Checked:

6" Max

GENERAL NOTES GROUND & SECOND FLOOR DEMO PLAN THIRD & FORTH FLOOR DEMO PLAN FIRST & SECOND FLOOR CONSTRUCTION PLAN THIRD AND FORTH FLOOR CONSTRUCTION PLAN ROOF CONSTRUCTION PLAN AND WALL TYPES SECOND & THIRD FLOOR RCP & POWER PLAN FOURTH FLOOR AND ROOF RCP & POWER PLAN SCHEDULES SCHEDULES ELEVATION

Project Title:

Floor Number:

ARCHITECTURAL DRAWINGS: T-001.00 A-001.00 A-002.00 A-003.00 A-004.00 A-005.00 A-006.00 A-007.00 A-008.00 A-009.00 A-010.00

6" Min 32" Max

4'-0" Max

6" Min

2'-3" Max

32" Max

6" Min

Note: Shower head and control area may be on back wall or on either side

32" Max

1. Smoke/Carbon Monoxide detectors or devices shall be installed in ordinance with the Housing Maintenance Code, Multiple Dwelling Law the New York City Building Code the New York City Electrical Code and LL 7/04. 2. Smoke Detectors and Carbon Monoxide Detectors may be combined providing the devices comply with the provisions of title 27 of the administrative code of the city of New York and any applicable rules promulgated thereunder. 3. Each Smoke/Carbon Monoxide Detector shall be installed in accordance with Reference Standard 17-12 of the New York City Building Code. 4. Each Smoke/Carbon Monoxide Detector shall be installed outside of each sleeping room in the immediate vicinity or within 10-0" of the entrance to a sleeping room. 5. Each Smoke/Carbon Monoxide Detector shall be of a type that allows for readily testing of such device. 6. Duplex units shall have a device located on each level if only one means of egress is provided from each level. 7. Ceiling mounted devices shall be a minimum distance of 4" from any wall. 8. Wall mounted devices shall be a minimum of 4" to a maximum of 12" from the ceiling. 9. Each dwelling unit shall be equipped with an approved type smoke/carbon monoxide detector device receiving primary power from the building wiring with no switches in the circuit other than the over current device protecting the branch circuit as per New York City Building Code Sec. 27-980. 10. Existing buildings that are not equipped with hardwired connections shall be supplied with battery operated devices. 11. Such smoke/carbon monoxide detector must be either the ionization chamber type or the photoelectric detector type as per New York City Building Code Sec. 27-981, (b). 12. A "Certificate of Satisfactory Installation for Smoke/Carbon Monoxide Detectors" must be filed with the division of code enforcement H.P.D., 10 days after installation. 13. Written information of testing and maintenance of the devices shall be provided to the dwelling unit owner.

Drawing Number:

3'-2" 2'-8"

TR8: HVAC SERVICE WATER HEATING EQUIPMENT HVAC SERVICE WATER HEATING SYSTEMS DUCT AND PIPING INSULATION ELECTRICAL METERING LIGHTING AND DWELLING UNITS INTERIOR LIGHTING POWER LIGHTING CONTROLS

2'-3" Max

ZONING INFORMATION

4'-6" Min 1'-0" Max 3'-6" Min

1. The general conditions of the American Institute of Architects for the contract of the construction of interiors, latest edition, is hereby made a part of this contract as if they were printed herein in full. 2. The contractor shall provide owner with all applicable certificates of insurance, liability and workman's compensation as required by law and building regulations. 3. The contractor shall take all necessary precautions to protect the owner, tenants and job site from damage or fire. 4. The contractor shall inspect the job site to verify all conditions, measurements and job requirements and shall report any inconsistencies to the architect immediately. 5. The contractor shall furnish all labor, materials, equipment, and services required to perform a finished job and for the proper completion of all trades whether or not such items are expressly mentioned in the contract documents. 6. The contractor shall coordinate the work of all trades and cooperate with the the work of all trades whether or not part of this contract. 7. All work performed must comply with all current rules and regulations of all municipal agencies having jurisdiction over this work and with all department of building rules and the rules of the particular building in which the work is located. 8. The job site shall be kept broom clean at all times. upon completion of the work the contractor shall provide a broom clean space, free of all dust and debris. 9. The owner's signature must be obtained prior to ordering any materials or executing any work in excess of the original contract. 10. All work shall comply with current trade practices and conform to the standards of good workmanship. 11. The contractor shall cause the owner and architect and their agents to be held harmless from all liabilities resulting from any and all situations resulting from this work. 12. The contractor shall maintain a complete and up to date set of drawings on the job site at all times. 13. The contractor shall prepare and submit shop drawings to the architect for approval. Contractor shall inspect shop drawings prior to submission and no material shall be ordered prior to approval of shop drawings. 14. The contractor shall protect all property from damage. Any damage caused by the contractor's workmen or sub-contractor's workmen shall be repaired or replaced at no cost to the owner. 15. Contractor shall coordinate the work of all trades and shall cooperate with all trades not specifically part of this contract. 16. Contractor shall submit samples to the architect of all finishes of hardware, wood, switch plates, stone, tile, etc., for approval, prior to ordering. 17. Contractor shall be responsible for arranging with building management for elevators and/or other hoisting facilities for the handling of materials and shall bear all costs for same. 18. Tenant shall, through its building code consultant, arrange for drawings to be filed with the building department in the municipality having jurisdiction over the work, and for final sign-off. Contractor shall obtain permits and all other licenses and sign-offs required and shall bear all costs for same. 19. General contractor shall properly protect the owner and any adjacent property or work. Any damage to the same caused by contractor's workmen or subcontractor's workmen shall be repaired or replaced without delay. Patching and replacing of damaged work shall be done by general contractor. General contractor shall provide all necessary protection for the work until same is turned over to the client. 20. Shareholder is responsible for all elec. radiant heat 21. No solenoids or restrictions on the building HVAC/fan coil units. 22. All cabinetry to be removable

1'-6"

01

TR1: FIRE STOP/DRAFT STOP/FIRE BLOCK MECHANICAL VENTILATION FINAL ENERGY CODE COMPLIANCE

Architect:

TENANT SAFETY NOTES: RENOVATION IN RESIDENTIAL BUILDING:

Note: Cross hatched areas to receive blocking for securing grab bars

CONTROLLED INSPECTIONS

PLOT PLAN (NTS)

0.

AIR CONDITIONING ADJUSTABLE ABOVE FINISH FLOOR ALUMINUM AS NOTED ARCHITECT ACOUSTIC TILE CEILING BUILDING BY OTHERS BUILDING STANDARD CABINET CABINET CONTRACTOR CENTERLINE CLOSET CEILING COLUMN CONCRETE CONTINUOUS CARPET CERAMIC TILE DOWN DOOR DETAIL DRAWING ELEVATION ELECTRIC EQUAL EXISTING TO BE RELOCATED ELECTRIC WATER COOLER EXISTING FURNISH & INSTALL FINISH FULL HEIGHT FLOOR FINISH OPENING FIREPROOF FIREPROOF SELF CLOSING FIRE RATED FRAME FLUSH VALVE GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GYPSUM WALL BOARD HOLLOW METAL HOLD OPEN HOUR HEIGHT HEATING/VENTILATION INSULATION INTERIOR INSTALL ONLY JANITOR CLOSET JUNCTION BOX JAMB OPENING JOINT LAVATORY LIGHTING MAXIMUM MINIMUM MECHANICAL MANUFACTURER MASONRY OPENING METAL NO HOLD OPENING NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OPENING OPPOSITE PLATE PLASTIC LAMINATE PLUMBING PLYWOOD PANEL POLISHED PAIR PAINT QUARRY TILE RADIUS REFLECTED REINFORCE REQUIRED ROOM SEPARATE CIRCUIT SIMILAR STAINLESS STEEL SPECIFICATION SPEAKER SPRINKLER SQUARE STANDARD STEEL STRUCTURAL TELEPHONE TRIMMED OPENING TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD VINYL TILE WITH WOOD

THERE IS NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION

A0

A/C ADJ AFF ALUM AN ARCH ATC BLDG BO BS CAB CABC CL CLOS CLG COL CONC CONT CPT CT DN DR DTL DWG EL ELEC EQ ER EWC EXTG F/I FIN FH FLR FO FP FPSC FR FRM FV GA GALV GC GL GWB HM HO HR HT HVAC INSUL INT I/O JAN CL JB JO JT LAV LTG MAX MIN MECH MRF MO MTL NHO NIC NO NTS OC OPNG OPP PL PLLA PLMB PLY PNL POL PR PT QT RAD REF REINF REQ'D RM SC SIM STNSTL SPEC SPKR SPR SQ STD STL STR TEL TO TYP UON VIF VT W/ WD

GENERAL NOTES

T-001.00 FOOT

BACK Note: Cross hatched areas to receive blocking for securing grab bars

LOCATION OF GRAB BAR REINFORCEMENTS AND CONTROLS OF ADAPTABLE BATHTUBS