Cyclebar Sunnyvale, CA Design Development

Page 1

9483 HAVEN AVENUE, SUITE 100

RANCHO CUCAMONGA, CA 91730 P. 909.259.9971 | F. 909.944.8409 www.AmorArch.com WEST COAST | CENTRAL | EAST COAST

310 W. WASHINGTON AVENUE SUNNYVALE, CA 94806

7.

8.

9.

SECTION DESIGNATION

DETAIL DESIGNATION X AX.0

SHEET REFERENCE NO.

INTERIOR ELEVATION IDENTIFICATION

0'-0" FINISH FLOOR

A DETAIL DESIGNATION 16 -

D

B SHEET REFERENCE NO.

SECTION / ELEVATION / FLOOR DATUM

N N

2016 CALIFORNIA PLUMBING CODE (CPC)

MECHANICAL CODE

2016 CALIFORNIA MECHANICAL CODE (CMC)

ELECTRICAL CODE

2016 CALIFORNIA ELECTRICAL CODE (CEC)

ENERGY CODE

2016 CALIFORNIA ENERGY CODE

FIRE / LIFE SAFETY CODE

2016 CALIFORNIA FIRE CODE (CFC) W/ LOCAL AMENDMENTS

A7.1 A8.2 A8.3 A8.4 A8.5

ENLARGED RESTROOM PLAN, INTERIOR ELEVATIONS & DETAILS INTERIOR ELEVATIONS INTERIOR ELEVATIONS WALL AND MISCELLANEOUS DETAILS ROOM FINISH PLAN, SCHEDULE & LEGEND WALL SIGNAGE AND GRAPHICS MILLWORK DETAILS (FOR REFERENCE ONLY) EQUIPMENT SPECIFICATIONS (FOR REFERENCE ONLY)

ACCESSIBILITY

PROJECT REFERENCE N

PLUMBING CODE

T2.1 A1.1 A2.1 A6.1 A6.2 A6.3

NORTH ARROW

THESE PLANS ARE INTENDED TO COMPLY WITH ALL OF THE PROVISIONS SET FORTH BY CHAPTER 11B OF THE 2016 CBC

C CODE COMPLIANCE GRID LINE IDENTIFICATION GRID LINE FACE OF STUD FACE OF MASONRY CENTER LINE OF COLUMN

1.0

IF A CONFLICT OCCURS BETWEEN THE DESIGN DRAWINGS AND SPECIFICATIONS, PROMPTLY NOTIFY THE ARCHITECT IN WRITING. AT THAT POINT, A WRITTEN INTERPRETATION WILL BE MADE BY THE ARCHITECT AND SAID WRITTEN DECISION SHALL BE CONSIDERED PART OF THE CONTRACT DOCUMENTS.

ALL CONTRACTORS WILL PROVIDE ADEQUATE BRACING AND / OR SHORING TO INSURE STRUCTURAL STABILITY OF THE BUILDING AND ALL RELATED BUILDING COMPONENTS, I.E.; STRUCTURAL WALLS, INTERIOR WALL ASSEMBLIES, ETC. DURING THE CONSTRUCTION PHASE OF THIS PROJECT.

ELEVATION REFERENCE IDENTIFICATION

ELEVATION DESIGNATION

CONTRACTOR IS RESPONSIBLE FOR THE MORE COSTLY AND TIME CONSUMING RESOLUTION ON ALL CONFLICTING INFORMATION PRESENTED ON THE PLANS, OR BETWEEN THE EXISTING CONDITIONS AND THE PLANS.

THIS ARCHITECT WILL NOT HAVE CONTROL OF, AND WILL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK ON THIS PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK ON THIS SITE, NOR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THE CONTRACT AND OR CONSTRUCTION DOCUMENTS.

SHEET REFERENCE NO.

2016 CALIFORNIA BUILDING CODE (CBC)

CONSULTANT

ADA STANDARDS - ACCESSIBLE DESIGN PLAN LIFE SAFETY PLAN (N) FLOOR PLAN AND EQUIPMENT PLAN (N) REFLECTED CEILING PLAN

A

PROJECT SYMBOL IDENTIFICATION 101

DOOR NUMBER

101

WINDOW NUMBER

P-2

MATERIAL NAME / FINISH NAME

W-1

ROOM IDENTIFICATION (E) CUSTOMER LOBBY CPT-1 B-1

WALL TYPE FIXTURE / EQUIPMENT TYPE

F-1 AP-1

ASSEMBLY EXISTING FIRE SPRINKLERED (NON-SEPARATED PER TABLE 508.4)

PROJECT ANNOTATION IDENTIFICATION

2

B

ASSESSOR PARCEL NUMBER:

209-07-018

BUILDING SUMMARY TENANT IMPROVEMENT AREA TENANT IMPROVEMENT AREA: TENANT GROSS LEASEABLE AREA

2,840 2,964

S.F. S.F.

(NO NEW S.F. ADDED)

TOTAL BUILDING HEIGHT

± 65'-0"

EXISTING MULTI-STORY (BUILDING HEIGHT TO REMAIN)

GRAPHIC NAME

FDXSCXX-1

2 ROOM NAME MATERIAL FINISH WALL BASE FINISH

A-3 II-B

LEGAL DESCRIPTION

F.O.M.

CEILING IDENTIFICATION MATERIAL DESIGNATION ACT-1 +10'-0" HEIGHT REFERENCE NOTE

OCCUPANCY GROUP: CONSTRUCTION TYPE:

REVISION / ADDENDUM NUMBER

PARKING SUMMARY SITE AND PARKING

(EXISTING TO REMAIN UNCHANGED)

1 KEYNOTE NUMBER TYP

WORK WILL BE COORDINATED WITH ALL TRADES IN ORDER TO AVOID INTERFERENCE AND AVOID OMISSIONS.

10. UNLESS NOTED OTHERWISE, ALL MATERIALS USED WILL BE NEW AND BEAR U.L. LABELS WHERE REQUIRED AND MEET APPROPRIATE N.E.M.A. OR OTHER INDUSTRY STANDARDS.

DEFERRED SUBMITTAL

PLUMBING FACILITY ANALYSIS

11. LAYOUT ALL PARTITIONS AND CABINETS BEFORE BEGINNING CONSTRUCTION TO PREVENT ERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONS AND CABINETS WILL BE INSTALLED AS NOTED ON THE DRAWINGS. IF APPLICABLE, GENERAL CONTRACTOR MUST OBTAIN RESOLUTION FROM ARCHITECT FOR ANY DISCREPANCIES PRIOR TO CONSTRUCTION OF WALL PARTITIONS AND CABINETS.

·

(N) EXTERIOR WALL MOUNTED BUILDING SIGNAGE

PER CALIFORNIA PLUMBING CODE 2016, TABLE 422.1 MINIMUM PLUMBING FACILITIES,

·

(N) INTERIOR AND EXTERIOR LED SIGNAGE

(OCCUPANT LOAD OF 26 MALE AND AND 26 FEMALE)

12. EACH SUBCONTRACTOR WILL AMEND AND MAKE GOOD AT THEIR OWN COST, ANY DEFECTS OR OTHER FAULTS IN THEIR WORKMANSHIP AND/OR THEIR SUPPLIED MATERIALS.

·

(E) FIRE SPRINKLER

13. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING AND / OR INSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANY DISCREPANCIES, CONTACT THE ARCHITECT FOR WRITTEN AND / OR GRAPHIC DIRECTION PRIOR TO PROCEEDING WITH THAT WORK.

16. WEATHER CONDITIONS: CONTRACTOR(S) WILL PROTECT ALL PARTS OF THEIR WORK FROM WEATHER DAMAGE DUE TO FROST, RAIN, HEAT, ETC. AND WILL MAKE GOOD TO THE SATISFACTION OF THE ARCHITECT ANY PORTION OF THE WORK WHICH MAY HAVE BECOME DAMAGED. 17. SITE SAFETY: EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS AND RELATED O.S.H.A. STANDARDS FOR THE PROTECTION AND SAFETY FOR THEIR EMPLOYEES ON SITE. THIS ARCHITECT WILL BE HELD HARMLESS BY CYCLEBAR AND GENERAL CONTRACTOR AND RELATED AWARDED TRADES ON THIS PROJECT FOR ACCIDENTS OR INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING THE PRE / ACTUAL / POST CONSTRUCTION PHASES OF THIS PROJECT. 18. CONTRACTORS WILL BE RESPONSIBLE FOR REMOVAL AND ACCOUNT FOR QUANTITY OF DEBRIS ACCUMULATED BY EACH TRADE. HOWEVER, EACH TRADE WILL KEEP THE JOB SITE CLEAN AND SAFE AT ALL TIMES, ALONG w/ A BROOM / VACUUM FINISH AT THE END OF EACH WORKING DAY. 19. TRANSITION OF DIFFERENT FLOORING MATERIALS AT DOORWAYS SHALL SHALL BE FLUSH AND OCCUR AT CENTERLINE OF DOORS TYPICALLY. 20. PAINT ALL WALL SURFACES, DOOR FRAMES, WINDOW FRAMES, BULKHEADS AND CEILINGS IN ROOMS WHERE INDICATED ON ROOM FINISH SCHEDULE. PAINT BEHIND ALL MOVEABLE ITEMS ADJACENT TO WALLS RECEIVING PAINT AND RELOCATE ITEMS. ALL NEW PAINTING SHALL INCLUDE (1) ONE COAT PRIMER AND (2) TWO COATS OF PAINT (UNLESS NOTED OTHERWISE).

LAVATORIES (FIXTURES PER PERSON)

STAMP

REQUIREMENT:

14. CONTRACTOR SHALL NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS OR INFORMATION, CONTRACTOR SHALL NOTIFY THE ARCHITECT. FIGURED AND CALCULATED DIMENSION TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TYPICALLY TAKES PRECEDENCE OVER SMALLER SCALE DRAWINGS VERIFY WITH ARCHITECT. ALL PLAN DETAILS AND WALL SECTIONS ARE ASSUMED TO BE TYPICAL CONDITIONS UNLESS DETAILED OR NOTED OTHERWISE. 15. PROVIDE SUFFICIENT BLOCKING IN STUD WALLS TO SUPPORT ALL ITEMS OR EQUIPMENT SHOWN OR SPECIFIED TO BE ATTACHED TO THE WALLS. PROVIDE ADDITIONAL STRUCTURAL SUPPORT (ANGLES, CHANNELS, ETC.) WITHIN WALLS WHERE THE WEIGHT OF ATTACHED ITEMS OR EQUIPMENT IS TOO GREAT TO BE SUPPORTED BY METAL STUDS. PROVIDE BLOCKING FOR OWNER FURNISHED OR INSTALLED ITEMS.

WATER CLOSETS (FIXTURES PER PERSON)

TITLE SHEET, PROJECT INFORMATION AND GENERAL NOTES

6.

SECTION DETAIL IDENTIFICATION

BUILDING CODE

GENERAL CONSTRUCTION NOTES & RESPONSIBILITY MATRIX

SHEET TITLE

5.

REVISIONS TO WORK OR PLANS MUST BE APPROVED BY THE CITY AND / OR LOCAL JURISDICTION's INSPECTION SERVICES PRIOR TO IMPLEMENTATION. ANY ADDITIONS OR CHANGES TO WORK MUST BE AUTHORIZED IN WRITING BY THE ARCHITECT AND OWNER. NO ALTERATIONS WILL BE MADE ON THIS PROJECT EXCEPT UPON WRITTEN ORDER BY USING PREDETERMINED ARCHITECT SUPPLEMENTAL INSTRUCTIONS, CHANGE ORDER OR CONSTRUCTION CHANGE DIRECTIVES.

SHEET REFERENCE NO.

PARTIAL SECTION IDENTIFICATION X AX.0

THE CONTRACTOR SHALL FOCUS SPECIAL ATTENTION ON A FIELD REVIEW OF THE EXISTING SITE IN WRITING PRIOR TO CONSTRUCTION. ANY CONDITIONS THAT ARE FOUND TO BE INCONSISTENT WITH THESE DOCUMENTS OR WHERE THE INTENT IS IN DOUBT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO BID SUBMITTAL. CONTRACTOR SHALL NOT RELY UPON ORAL COMMUNICATIONS; ALL COMMUNICATIONS MUST BE IN WRITTEN OR GRAPHIC FORMAT.

CURRENT CODES

TITLE SHEET, PROJECT INFORMATION, AND GENERAL NOTES

310 W. WASHINGTON AVENUE SUNNYVALE, CA 94086

4.

HVAC, PLUMBING AND ELECTRICAL DRAWINGS ARE INCLUDED IN, AND NOT SUPPLEMENTARY TO, THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK THE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND OTHER DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION BY THE CONTRACTOR FOR WRITTEN AND GRAPHIC CLARIFICATION.

T1.1 T1.2 T1.3

CYCLEBAR

3.

SHEET REFERENCE NO.

PHONE: (650) 283-6357 jihan.bayyari@cyclebar.com

1 2 3 4 5

PROJECT LOCATION

2.

X AX.0

REVISIONS

PROPOSED TENANT IMPROVEMENT FOR AN INDOOR EXERCISE BIKES STUDIO

DETAIL DESIGNATION

ELEVATION DESIGNATION X AX.0

PROPOSED USE

MECHANICAL

ANGLE LAMINATED LAVATORY POUND(S) LONG LINEAR FOOT LIGHT MATERIAL MAXIMUM / MINIMUM MACHINE BOLT MEZZANINE BD. BOARD MISCELLANEOUS BLDG BUILDING MASONRY OPENING BLK'G BLOCKING MODULAR PANELBOARD B.N. BOUNDARY NAIL SYSTEM BM. BEAM M.S.B. MAIN SWITCH BOARD B.O.C. BOTTOM OF CEILING MTD. MOUNTED B.O.J. BOTTOM OF JOIST MTL. METAL B.U.R. BUILT-UP ROOFING (N) NEW BOTT. or (B) BOTTOM NA OR N/A NOT APPLICABLE CND. CONDUIT N.E.M.A. NAT. ELEC. MFR. ASSOC. C.L. or CL CENTER LINE N.I.C. NOT IN CONTRACT CAB. CABINET NO. or # NUMBER C.B.B. CEMENTITIOUS BACKER BOARD NOM. NOMINAL C.D. CORE DRILL N.T.S. NOT TO SCALE CER. CERAMIC O.C. ON CENTER C.G. CORNER GUARD O.F.C.I. OWNER FURNISHED, C.J. CONTROL JOINT (COLD JOINT) CONTRACTOR INSTALLED CLG. CEILING OFD. OVERFLOW DRAIN CLKG. CAULKING O.F.O.I. OWNER FURNISHED, CLR. CLEAR OWNER INSTALLED C.M.U. CONCRETE MASONRY UNIT O.D. OUTSIDE DIAMETER COL. COLUMN OPN'G. OPENING CONC. CONCRETE OPP. OPPOSITE CONN. CONNECTION O.S.H.A. OCCUPATIONAL SAFETY & CONST. CONSTRUCTION HEALTH ADMINISTRATION CONST. JT. CONSTRUCTION JOINT PART'N PARTITION CONT. CONTINUOUS P. LAM PLASTIC LAMINATE OR CONTR. CONTRACTOR PARALLAM (BEAM) COMP COMPACTED / COMPACTION PL. PLATE C.T. CERAMIC TILE P.L. or PL PROPERTY LINE DBL. DOUBLE PLAS. PLASTER DEG. or ° DEGREE PLBG. PLUMBING DET. DETAIL PLYWD. PLYWOOD DIA. or Ø DIAMETER P.O.C. POINT OF CONNECTION DIAG. DIAGONAL PR. PAIR DIM. DIMENSION PSF POUNDS PER SQ. FOOT DS. DOWNSPOUT PSI POUNDS PER SQ. INCH DWG.(S) DRAWING(S) P.T. PRESSURE TREATED (E) EXISTING Q.T. QUARRY TILE EA. EACH RAD. OR (R) RADIUS E.C. ELECTRICAL CONTRACTOR RCP REFLECTED CEILING PLAN E.G. EDGE GRAIN R.D. ROOF DRAIN ELEC. ELECTRICAL REF. REFERENCE ELEV. ELEVATION REINF. REINFORCEMENT E.N. EDGE NAIL REV. REVERSE E.O.C. EDGE OF COUNTER / EQUIPMENT R.T.U. REMOTE TERMINAL UNIT EQ. or = EQUAL RQMTS. REQUIREMENTS ER EXISTING RELOCATED S.C. SOLID CORE EXP. EXPANSION SCHED. SCHEDULE EXT. EXTERIOR SHT. SHEET FACT. FACTORY SHT'G SHEATHING F.D. FLOOR DRAIN SIM. SIMILAR FDN. FOUNDATION SM SHEET METAL F.E. FIRE EXTINGUISHER SMS SHEET METAL SCREW F.F. FINISHED FLOOR SPEC.(S) SPECIFICATION(S) F.F.L. FINISHED FLOOR LEVEL SQ. SQUARE F.F. & E. FURNITURE, FIXTURES & SQ. IN. / FT. SQUARE INCH / FOOT EQUIPMENT S.S. STAINLESS STEEL F.G. FLOAT GLASS S.T.S.M.S. SELF TAPPING FLR. FLOOR SHEET METAL SCREWS FIN. FINISH STD. STANDARD FACE OF FINISH F.O.F. STL. STEEL F.O.M. FACE OF MASONRY STOR. STORAGE F.O.S. FACE OF STUD STRUCT. STRUCTURAL F.R. FIRE RETARDANT SUSP. SUSPENDED F.R.P. FIBERGLASS REINFORCED PANEL SYM. SYMMETRICAL FT. FOOT / FEET TEMP. OR T° TEMPERATURE FTG. FOOTING THK. THICKNESS F.V. FIELD VERIFY T&G TONGUE & GROOVE GA. GAUGE (GAGE) T.N. TOE NAIL G.B. GRAB BAR T.O.B. TOP OF BEAM G.WB. GYPSUM WALLBOARD T.O.C. TOP OF CURB G.C. GENERAL CONTRACTOR T.O.F. TOP OF FOOTING GALV. GALVANIZED T.O.P. TOP OF PARAPET G.I. GALVANIZED IRON T.O.PL. TOP OF PLATE GL.B. GLUE-LAMINATED BEAM T.O.S. TOP OF SLAB HB HOSE BIBB T.O.W. TOP OF WALL H.C. HOLLOW CORE T.S. TOP OF SHEATHING H.D. HUB DRAIN TYP. TYPICAL HDR. HEADER U.N.O. UNLESS NOTED OTHERWISE HDW. HARDWARE U.L. UNDERWRITERS LABORATORY HGR. HANGER VERT. OR (V) VERTICAL HGT. or HT. HEIGHT V.I.F. VERIFY IN FIELD H.M. HOLLOW METAL V.T.R. VENT THROUGH ROOF HORIZ. or H HORIZONTAL V.W.C. VINYL WALL COVERING H.S.B. HIGH STRENGTH BOLT W/ or W/O WITH, WITHOUT I.D. INSIDE DIAMETER W/C WATER CLOSET I.E. IN EXAMPLE WD. WOOD IN. INCH / INCHES WH WATER HEATER INSUL. INSULATION W.I.B. WALK-IN BOX INT. INTERIOR W.R. WATER RESISTANT INV. INVERTED WT. WEIGHT JT. OR JNT. JOINT WWF. WELDED WIRE FABRIC JST. JOIST WWM. WELDED WIRE MESH

ENLARGED DETAIL IDENTIFICATION

PLUMBING

L LAM. LAV. LB(S). or # LG. LFT. LT. MAT'L. MAX. / MIN. M.B. MEZZ. MISC. M.O. M.P.S.

ELEVATION IDENTIFICATION

310 W. WASHINGTON AVE SUNNYVALE, CA 94086

ELECTRICAL

ANCHOR BOLT ABOVE ASPHALTIC CONCRETE ALUM. COMPOSITE METAL PANEL ACOUSTIC CEILING PANEL ABOVE FINISH FLOOR ALUMINUM ABRASIVE QUARRY TILE ARCHITECT OF RECORD ARCHITECTURAL

ALL CONTRACTORS AND SUBCONTRACTORS WILL THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE CONSTRUCTION DOCUMENTS AND WILL VERIFY EXISTING SITE AND CONDITIONS PRIOR TO SUBMITTING A BID. ALL SUBCONTRACTORS WILL PROVIDE ALL LABOR, SUPERVISION, AND MATERIALS OF EVERY TYPE WHICH MAY BE NECESSARY FOR A SUCCESSFUL COMPLETION. ALL WORK TO BE PERFORMED IN A GOOD AND WORKMANLIKE MANNER ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS.

SHEET INDEX

MALE 1:1-125

FEMALE 1:1-65

MALE 1:1-200

FEMALE 1:1-200

MALE 1

FEMALE 1

MALE 1

FEMALE 1

PROVIDED:

NOTE: ALL INTERIOR LED SIGNAGE AND EXTERIOR SIGNAGE WILL BE UNDER SEPARATE APPLICATION SUBMITTAL BY OWNER.

SHEETS BEARING THIS SEAL AND WET SIGNATURE ARE AUTHENTICATED. RESPONSIBILITY FOR ALL OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS ARE DISCLAIMED.

DESCRIPTIVE SUMMARY OF WORK THE WORK INCLUDES ALL LABOR, MATERIALS, AND EQUIPMENT TO BUILD, FINISH, AND PROVIDE TENANT IMPROVEMENT FOR A PROPOSED CORPORATE INDOOR EXERCISE BIKES STUDIO. THE WORK SHALL INCLUDE ALL ITEMS REQUIRED AS SHOWN ON THE DRAWINGS. ALL MECHANICAL EQUIPMENT AND SYSTEMS, ALL ELECTRICAL SYSTEMS, AND EQUIPMENT ARE TO BE INCLUDED FOR A COMPLETE OPERATING SYSTEM WITH COORDINATION AND INSTALLATION INCLUDED. INTERIOR: NEW FINISHES (PAINT, FLOORING, GRAPHICS, ETC.) NEW FIXTURES NEW WALLS

21. ALL WEATHER - EXPOSED SURFACES SHALL HAVE A WEATHER RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF.

C COPYRIGHT 2019 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL.

PROJECT TEAM TENANT CYCLEBAR 310 W. WASHINGTON AVENUE SUNNYVALE, CA 94086 CONTACT: JIHAN BAYYARI PHONE: (650) 283-6357 EMAIL: jihan.bayyari@cyclebar.com

ARCHITECT AMORARCHITECTURALCORPORATION 9483HAVENAVENUE,SUITE100 RANCHOCUCAMONGA,CA91730 CONTACT: JOSEREYNOSO PROJECTMANAGER PHONE: (909)259-9971 FAX: (909)944-8409 EMAIL: jreynoso@amorarch.com

MECHANICAL, & ELECTRICAL

PLUMBING

REVISIONS

VICINITY MAP THIS MAP IS REFERRED FROM GOOGLE MAPS WEBSITE

DUNHAMENGINEERING 50SOUTHSTREET,SUITE1100 MINNEAPOLIS,MN55402 CONTACT: CULLENMURTAUGH PROJECTMANAGER PHONE: (612)465-7550 FAX: (612)465-7551 EMAIL: Cullen.Murtaugh@dunhameng.com

APPROVED VENDOR SUPERIORPERFORMANCESURFACING CONTACT: KENNYFLAKE PHONE: (713)805-8296 EMAIL: kenny@spsurfacing.org PLATINUMSLV,LLC 4416SUNBELTDR. ADDISON,TX75001 CONTACT: ERICGALDIANO PHONE: (972)380-9500 EMAIL: egaldiano@platinumslv.com

DATE 2019.09.03

PROJECT SITE

PROJECT NUMBER A2214

SHEET NUMBER

N

T1.1

30% SET : 2019_09_03

Plotted: 9/9/2019 10:23 AM (jlavenant) File: 01_a2214_t1.1_title sheet.dwg

A.B. ABV. A.C. ACM A.C.P. A.F.F. ALUM. A.Q.T. AOR ARCH.

1.

F.O.S.

(NOT ALL ABBREVIATIONS MAY BE USED IN THIS DOCUMENT)

PROJECT INFORMATION

SYMBOL LEGEND

ARCHITECTURAL

GENERAL NOTES

ABBREVIATIONS

CLIENT


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.