ARCHITECTURAL CONCEPT DESIGN - RESIDENTIAL BUILDING

Page 1

CITISCAPE

Architectural Consulting

352 EAST 119 STREET Manhattan, NY 10035

05/01/2017


CITISCAPE

Architectural Consulting

352 EAST 119 STREET Manhattan, NY 10035

05/01/2017







CITISCAPE

Architectural Consulting

352 EAST 119 STREET Manhattan, NY 10035

05/01/2017


PROPOSED PLANS

SMOKE DETECTOR NOTES PROPERTY LINE 20'-0"

PROPERTY LINE 20'-0"

10' - 0"

50' - 6"

50' - 6" 10' - 0" 1

10' - 0"

PROPERTY LINE 50'-6"

10' - 0"

PROPERTY LINE 50'-6"

43' - 7"

50' - 6"

10' - 0"

1. SMOKE DETECTING DEVICES SHALL CONFIRM TO SUBCHAPTER 17, ARTICLE 6 OF THE BUILDING CODE. 2. SMOKE DETECTING DEVICES SHALL REVIVE THEIR PRIMARY POWER FROM BUILDING WRITING. THERE SHALL BE NO SWITCHES IN THE CIRCUIT OTHER THAN THE OVER CURRENT DEVICE PROTECTING THE BRANCH CIRCUIT. 3. ALL SMOKE DETECTING DEVICES SHALL BE ACCEPTED PURSUANT TO RULES AND REGULATIONS PROMULGATED BY THE COMMISSIONER, APPROVED BY THE BOARD OF STANDARDS AND APPEALS OR LISTED BY A NATIONALLY RECOGNIZED INDEPENDENT LABORATORY. NO DEVICE SHALL BE DEEMED TO BE IN COMPLIANCE WITH THIS PROVISION UNLESS IT IS OF EITHER THE IONIZATION OR PHOTOELECTRIC TYPE.

REAR YARD

A-003.00

ENTRANCE (1ST FL)

1. CARBON MONOXIDE DETECTION DEVICES SHALL CONFORM TO LOCAL LAW 7 OF 2004, DOB RULES RNCY 28 - 02 AND BUILDING CODE REFERENCE STANDARD 17-13 AND 17-14 2. CARBON MONOXIDE DETECTION DEVICES SHALL RECEIVE THEIR PRIMARY POWER FROM BUILDING WIRING SHALL BE NO SWITCHES IN THE CIRCUIT OTHER THAN THE OVER CURRENT DEVICE PROTECTING THE BRANCH CIRCUIT. 3. SUCH DEVICES SHALL BE LOCATED WITHIN 15 FEET ANY ROOM USED FOR SLEEPING PURPOSES , AS PER CHAPTER 28 OF THE RULES AND REGULATIONS. 4. ALL CARBON MONOXIDE DETECTION DEVICES SHALL BE ACCEPTED PURSUANT TO RULES AND REGULATIONS PROMULGATED BY THE COMMISSIONER, APPROVED BY THE BOARD OF STANDARDS AND APPEALS OR LISTED BY A NATURALLY RECOGNIZED INDEPENDENT LABORATORY. NO DEVISE SHALL BE DEEMED TO BE IN COMPLIANCE WITH THIS PROVISION UNLESS IT IS OF EITHER THE IONIZATION OR PHOTO - ELECTRIC TYPE.

A-003.00

8"

6' - 10"

2' - 6"

Architectural Consulting

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

CARBON MONOXIDE DETECTOR NOTES

9' - 0"

1

CITISCAPE

PLAN EXAMINERS SIGN & SEAL :

DOB PERFORATION :

6' - 11"

WALL TYPE 1 1 HOUR RATED INTERIOR NON-BEARING PARTITION WITHIN DWELLING UNITS

100' - 11"

100' - 11"

PROPERTY LINE 20'-0"

BSA# 301- 60SM UL U419 MEA 81-98-M

3 5/8" 5/8"

REAR YARD

R NEW GAS RANGE KITCHENETTE 75 SF

DWELLING UNIT 02 391 SQ.FT CMD/SD NEW DRAIN NEW BOILER NEW HWH

R

2

9' - 0"

6"

ADJACENT BUILDING

RESTROOM 37 SF

LOBBY AND RECREATION SPACE 98 SF 8' - 6"

FINISH FLOOR 1 HR 3' 4" PLYWOOD SUBFLOOR NOTES: 3 5/8" METAL STUDS @ 16" O.C. w/ (1) LAYER, FC #60, 5/8" THK G.W.B. ON BOTH SIDES, (1) HR FIRE RATED, BSA CAL #301-60 SM 3 5/8" 5/8" 5/8"NTS 3 5/8" METAL STUDS @ 16" O.C.

PROJECT NUMBER:

M-42 352 EAST 119 STREET, MANHATTAN, NY KEY PLAN

WALL TYPE 2

TAPE JOINT & CEMENT TYP, EA, SIDE AUCOUSTIC TYP, EA, SIDE 4" 20 GA METAL CLG RUNNER 4" 20 GA METAL STUD @ 16" O.C.

STAIRWAY 110 SF NEW BOILER NEW HWH NEW DRAIN

NEW SHOWER

NEW LAVA

4" 20 GA METAL RUNNER

UP

A-003.00

ADJACENT BUILDING

R

CLOSET 5 SF

BATHROOM 37 SF

5/8"

5/8"

(1) LAYER OF 5/8" SHEETROCK BRAND FIRECODE CORE GYPSUM

CORRIDOR 38 SF

R

DWELLING UNIT 01 325 SQ.FT BEDROOM 95 SF

FILING NUMBER:

5/8"

R

4" 20 GA METAL RUNNER FINISH FLOOR

NEW TOILET NEW LAVA

7' - 8"

3 5/8"

5/8"

NEW SINK

RETAIL 268 SF

R

KITCHEN/DINING ROOM 141 SF CMD/SD 5" 10' - 0"

BIS BAR CODE STICKER:

3' 4" PLYWOOD SUBFLOOR

SHEET TITLE:

PROPOSED PLANS STUDS: CHANNEL SHAPED, FABRICATED FROM MIN 25 MSG CORROSION PROTECTED STEEL, MIN WIDTH 1-1/4" FLANGES AMD 1/4" IN RETURN SPACED A MAX OF 24" OC STUDS TO BE CUT 3/8" TO 3/4" LESS THAN ASSEMBLY HEIGHT

SHEET #:

A-001.00 PAGES:

DATE:

LEGEND:

05/01/2017 ARCHITECT SIGN & SEAL

EXISTING PARTITION ENTRANCE (RESIDENTIAL 1ST FL)

ENTRANCE (RETAIL 1ST FL)

3' - 1"

13' - 10" 20' - 0"

2' - 1" 1' - 0"

D-5 30" x 84" - NEW DOOR 1-1/2 hr-F.P.S.C

503 SQ.FT 2 A-001.00

1ST FLOOR 1/4" = 1'-0"

PROPERTY LINE 20'-0"

CMD/SD

DN

983 SQ.FT 3 A-001.00

2ND FLOOR 1/4" = 1'-0"

(TYPE) (DIMENSIONS) (FIRE-RATED)

NEW PARTITION W-1 30" x 74"

20' - 0"

DATE

BSA# 301- 60SM UL U411 STC RATING: 50-40

ADJACENT BUILDING

40' - 5"

UP

NEW TOILET

CORRIDOR 48 SF

NEW GAS RANGE

2

BC 1021.2.4.5 OPEN, UNOBSTRUCTED AND DIRECT ACCESS TO THE STREET

DESCRIPTION

6"

50' - 5"

50' - 5"

CORRIDOR 188 SF

REV. #

2 HOUR INTERIOR NON-BEARING PARTITION BETWEEN DWELLING UNITS AND MECHANICAL ROOMS

R

3' - 6"

A-003.00

PROPERTY LINE 100'-11"

PROPERTY LINE 50'-5"

GAS METER ROOM 27 SF

PROPERTY LINE 100'-11"

6"

STAIRWAY 32 SF

(1) LAYER OF 5/8" SHEETROCK BRAND FIRECODE CORE GYPSUM

LIVING ROOM 208 SF

ELECTRIC METER ROOM 28 SF 6" 4' - 4" 3' - 8"

9' - 0"

Manhattan, NY 10035

4" 20 GA METAL STUD @ 16" O.C.

MECHANICAL ROOM 22 SF

ENTRANCE (1ST FL)

352 EAST 119 STREET

AUCOUSTIC TYP, EA, SIDE 5/8" 4" 20 GA METAL CLG RUNNER

8' - 4"

BATHROOM 33 SF

ADJACENT BUILDING

PROJECT TITLE TAPE JOINT & CEMENT TYP, EA, SIDE

MECHANICAL ROOM 17 SF

43' - 9"

PROPERTY LINE 50'-5"

10' - 0" PROPOSED REAR YARD

100' - 11"

PROPERTY LINE 20'-0"

PROPERTY LINE 20'-0" R

- NEW WINDOW

(TYPE) (DIMENSIONS)

INTERCONNECTED SMOKE DETECTOR. CARBON MONOXIDE DETECTOR MECHANICAL VENTILATION (EXHAUST 75CFM - 100CFM)

1

- NEW PARTITION TYPE

3 OF 6


PROPOSED PLANS

ROOF PLAN

CITISCAPE

Architectural Consulting

10' - 0"

A-003.00

1

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

PROPERTY LINE 50'-6"

1

PROPERTY LINE 20'-0"

50' - 6"

50' - 6"

PROPERTY LINE 50'-6"

PROPERTY LINE 20'-0"

50' - 6"

PROPERTY LINE 50'-6"

50' - 6"

50' - 6"

PROPERTY LINE 20'-0"

50' - 6"

10' - 0"

A-003.00

10' - 0"

PLAN EXAMINERS SIGN & SEAL :

1 A-003.00

DOB PERFORATION :

10' - 0"

10' - 0"

2" 1/2" / 1

PROPERTY LINE 20'-0"

100' - 11"

PROPERTY LINE 20'-0"

100' - 11"

100' - 11"

PROPERTY LINE 20'-0"

PROJECT TITLE

RAINWATER DRAIN

352 EAST 119 STREET

1/2" / 12"

Manhattan, NY 10035

50' - 5"

DN

2

FILING NUMBER:

A-003.00

BATHROOM 6" 29 SF4' - 6"

DN

CMD/SD

BIS BAR CODE STICKER:

R

KITCHENETTE 83 SF

CORRIDOR 26 SF

NEW LAVA UP CMD/SD

LIVING/KITCHEN/DINING 178 SF

DWELLING UNIT 07 R 515 SQ.FT

2' - 7"

3' - 9"

7' - 11"

BATHROOM 32 SF NEW TOILET

12' - 0"

DWELLING UNIT 07 1' - 6"

7' - 5"

11' - 1"

18' - 8"

1/2" / 12"

ADJACENT BUILDING

NEW GAS RANGE

NEW SINK

BEDROOM 155 SF

ADJACENT BUILDING

NEW SINK

CMD/SD

NEW LAVA

R

NEW TOILET NEW LAVA

BEDROOM 95 SF

R

NEW GAS RANGE

CORRIDOR 38 SF

DWELLING UNIT 03 325 SQ.FT

R

6"

R R

A-003.00

NEW HWH

ADJACENT BUILDING

CLOSET 5 SF

BATHROOM 37 SF

NEW SHOWER NEW TOILET

STAIRWAY 79 SF

2

ADJACENT BUILDING

ADJACENT BUILDING

NEW SHOWER

NEW BOILER

A-003.00

ADJACENT BUILDING

A-003.00

2

ADJACENT BUILDING

2

STAIRWAY 110 SF

PROPERTY LINE 100'-11"

LADDER 3'-0"

50' - 5"

50' - 5"

A-003.00

NEW DRAIN

STAIRWAY 110 SF NEW BOILER NEW HWH NEW DRAIN

1 A-003.00

CORRIDOR 48 SF

R

50' - 5"

50' - 5"

R

KEY PLAN

RAINWATER RAINWATERDRAIN DRAIN

LADDER 3'-0"

ADJACENT BUILDING

R

M-42 352 EAST 119 STREET, MANHATTAN, NY

1/2" / 12"

CORRIDOR 48 SF

PROJECT NUMBER:

5

NEW HWH

SHEET TITLE:

PROPOSED PLANS

SHEET #:

A-002.00

RAINWATER DRAIN

KITCHEN/DINING ROOM 139 SF

20' - 0"

PAGES:

DATE:

05/01/2017 ARCHITECT SIGN & SEAL

20' - 0"

20' - 0"

983 SQ.FT 7 A-002.00

3RD FLOOR 1/4" = 1'-0"

20' - 0"

983 SQ.FT PROPERTY LINE 20'-0"

1 A-002.00

4TH FLOOR 1/4" = 1'-0"

323 SQ.FT

PROPERTY LINE 20'-0"

DATE

8"

33 SF

5' - 2"

6' - 6"

A-003.00

2' - 6" 6' - 7"

0"

R

5 BATHROOM

11' - 8"

DESCRIPTION

2' - 7"

NEW HWH

NEW DRAIN NEW BOILER

1/2" / 12"

5' - 10"

BATHROOM 33 SF

CMD/SD

RAINWATER DRAIN

1/2" / 12"

NEW DRAIN NEW BOILER

KITCHENETTE 75 SF

PROPERTY LINE 50'-5"

CMD/SD

DWELLING UNIT 06 R 391 SQ.FT

50' - 5"

KITCHENETTE 75 SF

PROPERTY LINE 100'-11"

R

PROPERTY LINE 50'-5"

DWELLING UNIT 04 391 SQ.FT

NEW GAS RANGE

REV. #

LIVING ROOM 211 SF

PROPERTY LINE 100'-11"

PROPERTY LINE 50'-5"

LIVING ROOM 211 SF

3 A-002.00

PENTHOUSE FLOOR 1/4" = 1'-0"

PROPERTY LINE 20'-0"

4 OF 6


SECTION 1-1

SECTION 2-2

AXONOMETRIC VIEW. SECTION 2-2

60' - 3"

60' - 3"

Architectural Consulting

8' - 0"

BULKHEAD

8' - 0"

BULKHEAD

ROOF

52' - 3"

52' - 3"

10' - 0"

BEDROOM 155 SF

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

10' - 0"

ROOF

STAIRWAY 79 SF

STAIRWAY 79 SF

PENTHOUSE FLOOR

PENTHOUSE FLOOR

42' - 3"

42' - 3"

LIVING/KITCHEN/DINING 178 SF

BATHROOM 32 SF

STAIRWAY 110 SF

CORRIDOR 48 SF

LIVING ROOM 211 SF

32' - 3"

32' - 3"

STAIRWAY 110 SF

CORRIDOR 48 SF

LIVING ROOM 211 SF

22' - 3"

22' - 3"

STAIRWAY 110 SF

CORRIDOR 48 SF

10' - 0"

3RD FLOOR

10' - 0"

3RD FLOOR

CORRIDOR 38 SF KITCHEN/DINING ROOM 141 SF

LIVING ROOM 208 SF

12' - 3"

12' - 3"

GAS METER ROOM MECHANICAL ROOM 27 SF 22 SF MECHANICAL ROOM ELECTRIC METER ROOM 17 SF 28 SF

12' - 0"

2ND FLOOR

12' - 0"

PROJECT TITLE

352 EAST 119 STREET Manhattan, NY 10035

STAIRWAY 110 SF REV. #

2ND FLOOR

LOBBY AND RECREATION SPACE 98 SF

DOB PERFORATION :

10' - 0"

4TH FLOOR

10' - 0"

4TH FLOOR

CORRIDOR KITCHEN/DINING ROOM 38 SF 139 SF

PLAN EXAMINERS SIGN & SEAL :

BATHROOM 29 SF

10' - 0"

10' - 0"

CITISCAPE

CORRIDOR 188 SF

STAIRWAY 32 SF

DESCRIPTION

DATE

PROJECT NUMBER:

M-42 352 EAST 119 STREET, MANHATTAN, NY KEY PLAN

1ST FLOOR

1ST FLOOR

0' - 3"

0' - 3" EXISTING CELLAR

CELLAR FLOOR -7' - 5"

AXONOMETRIC VIEW. SECTION 1-1

FACADE DETAIL. STREET ENTRANCE

SECTION 3-3

AXONOMETRIC VIEW, SECTION 3-3

FILING NUMBER:

BIS BAR CODE STICKER:

BULKHEAD 60' - 3"

SHEET TITLE:

SECTION 1-1, 2-2

ROOF

SHEET #:

52' - 3"

A-003.00 PAGES:

DATE:

BEDROOM 155 SF

05/01/2017 ARCHITECT SIGN & SEAL

PENTHOUSE FLOOR 42' - 3"

LIVING/KITCHEN/DINING 178 SF KITCHENETTE 83 SF

4TH FLOOR 32' - 3"

5 OF 6


FRONT FACADE

REAR FACADE

PERSPECTIVE VIEW 1

PERSPECTIVE VIEW 2

CITISCAPE

Architectural Consulting

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

BULKHEAD

60' - 3"

60' - 3"

PLAN EXAMINERS SIGN & SEAL :

8' - 0"

8' - 0"

BULKHEAD

DOB PERFORATION :

ROOF

52' - 3"

52' - 3"

10' - 0"

10' - 0"

ROOF

PROJECT TITLE

PENTHOUSE FLOOR

PENTHOUSE FLOOR

42' - 3"

42' - 3"

352 EAST 119 STREET

10' - 0"

10' - 0"

Manhattan, NY 10035

REV. #

32' - 3"

32' - 3"

10' - 0" 3RD FLOOR

22' - 3"

22' - 3"

M-42 352 EAST 119 STREET, MANHATTAN, NY KEY PLAN

10' - 0"

10' - 0"

3RD FLOOR

DATE

PROJECT NUMBER:

52' - 0" PROPOSED BUILDING HEIGHT

4TH FLOOR

52' - 0" PROPOSED BUILDING HEIGHT 10' - 0"

4TH FLOOR

DESCRIPTION

FILING NUMBER:

2ND FLOOR

2ND FLOOR

12' - 3"

12' - 3"

AXONOMETRIC VIEW - FRONT FACADE

AXONOMETRIC VIEW - REAR FACADE

12' - 0"

12' - 0"

BIS BAR CODE STICKER:

SHEET TITLE:

FACADES 1ST FLOOR

1ST FLOOR

0' - 3"

0' - 3"

7' - 8"

SHEET #:

A-004.00 PAGES:

DATE:

05/01/2017 ARCHITECT SIGN & SEAL

CELLAR FLOOR -7' - 5"

6 OF 6


DEMOLITION NOTES

DEMOLITION PLANS

CITISCAPE

Architectural Consulting

2'-9"

H=6'-3"

2'-8" 2'-0"

PROPERTY LINE 50'-6"

9'-8"

CONCRETE WALKWAY

PROPERTY LINE 20'-0"

PROPERTY LINE 50'-6"

11'-8"

CMU WALL

40'-8"

PROPERTY LINE 50'-6"

GRASS

PROPERTY LINE 20'-0"

H=7'-1"

PROPERTY LINE 20'-0"

PROPERTY LINE 50'-6"

PROPERTY LINE 20'-0"

1. CONTRACTOR SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED BY THE WORK. ALL WORK SHALL BE DONE CAREFULLY AND NEATLY, IN A SYSTEMATIC MANNER. 2. ALL EXISTING SURFACES AND EQUIPMENT TO REMAIN SHALL BE FULLY PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE AND SHALL MAKE REPAIRS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. 3. NO DEBRIS SHALL BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AS THE JOB PROCEEDS. THE SITE SHALL BE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION. 4. NO STRUCTURAL ELEMENTS SHALL BE REMOVED UNLESS PORTIONS AFFECTED ARE ADEQUATELY SUPPORTED BY EITHER TEMPORARY SHORING OR NEW STRUCTURAL ELEMENTS AS REQUIRED TO PROTECT THE STABILITY AND INTEGRITY OF THE EXISTING STRUCTURE. 5. ALL ADJOINING PROPERTY AFFECTED BY ANY OPERATIONS OF DEMOLITION SHALL BE PROTECTED PER THE REQUIREMENTS OF SUBCHAPTER 19 OF THE NYC BUILDING CODE. 6. REMOVE OR RELOCATE ALL WIRING, PLUMBING, AND MECHANICAL EQUIPMENT AFFECTED BY REMOVAL OR PARTITIONS. REMOVED PIPES AND/OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW FINISH SURFACES, AND SHALL BE PROPERLY CAPPED OR PLUGGED. 7. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN ALL TEMPORARY BARRIER AND GUARDS, AND ALL TEMPORARY SHORING AND BRACING AS REQUIRED BY DEPARTMENT OF BUILDINGS RULES AND REGULATIONS. 8. THE CONTRACTOR SHALL PROVIDE ADEQUATE WEATHER PROTECTION FOR THE BUILDING AND ITS CONTENTS DURING THE COURSE OF THE WORK. ALL OPENINGS IN ANY WALL OR ROOF SHALL BE PROTECTED FROM ALL FORMS OF WEATHER OR WATER PENETRATION. 9. THE CONTRACTOR SHALL FILE ALL NECESSARY CERTIFICATES OF INSURANCE WITH THE DEPARTMENT OF BUILDINGS, PAY ALL FEES, OBTAIN ALL PERMITS AND PROVIDE ANY AND ALL BONDS REQUIRED BY ANY CITY AGENCY IN ORDER TO DO THE WORK HEREIN DESCRIBED.

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

PLAN EXAMINERS SIGN & SEAL :

DOB PERFORATION :

PROJECT TITLE

352 EAST 119 STREET Manhattan, NY 10035

DN

3'-0"

3'-2" 2'-6"

3'-2" 2'-5"

3'-9"

2'-5"

PROJECT NUMBER:

3'-10"

2'-4"

M-42 352 EAST 119 STREET, MANHATTAN, NY

3'-4"

1'-4"

100'-11" PROPERTY LINE 100'-11"

8'-71/4"

43/4" 8'-4"

FILING NUMBER: KITCHEN / LIVING ROOM H=7'-9"

EXIST. ELECT. GAS RANGE

LEGEND

EXIST SINK

BLOCKED CHIMNEY

19'-3"

4'-01/2" 2'-4"

2'-111/4"

8'-71/4"

1'-5" 3'-4"

RAILINGS

BATHROOM H=7'-9"

3'-7"

15'-7"

UP

4'-2" 2'-4"

EXIST. BATH TUB

17'-10"

PROPERTY LINE 50'-5"

11'-7" 1'-8"

29'-5"

2'-111/4"

6'-17/8"

EXIST SINK

BIS BAR CODE STICKER:

2'-4"

SHEET TITLE:

4'-2" 2'-4"

2'-4"

ADJACENT BUILDING

18'-9"

RAMP UP

2'-4"

BLOCKED CHIMNEY

1'-5"

13'-1"

EXIST SINK

BATHROOM EXIST TOILETH=8'-2" 43,2 SQ.FT.

7"

1'-0"

5'-11"

EXIST LAV.

H=8'-1"

CL.

EXIST. TOILET

7'-0"

BEDROOM H=7'-9"

50'-5"

14'-6"

10'-1"

15'-9"

EXIST. BATH TUB

5"

OFFICE

4'-117/8"

H=8'-4" 60,7 SQ.FT.

4'-13/4"

CORRIDOR 2'-10"

4'-01/2"

2'-3"

100'-11" PROPERTY LINE 100'-11"

8'-71/4" 43/4" 43/4"

DN

3'-0" 1'-5"

10'-9" 2'-4"

28'-10"

PROPERTY LINE 50'-5"

100'-11"

UP

1'-3"

ADJACENT BUILDING

1'-4"

5'-10"

11'-8"

2'-4"2'-1"

HATCH DOOR TO CELLAR

6'-1"

5"

11'-7"

ADJACENT BUILDING

4'-4"

EXIST. ELECTR. GAS RANGE EXIST SINK

5'-41/4"

2'-4" 10"

1'-6" 2'-8"

1'-0"

11'-11"

1'-4"

KEY PLAN 1'-6"

H=7'-5"

7'-5"

5"

PROPERTY LINE 100'-11"

5'-10" 19'-6"

11'-10"

11'-1"

ADJACENT BUILDING

1'-8" 5'-2"

7'-2"

3'-7"

KITCHEN

17'-101/2"

50'-5"

2'-8"

OFFICE

1'-4"

ADJACENT BUILDING

UP

4'-11"

5" 3'-0" 3'-0" 4'-2"

H=8'-5"

H=8'-5"

11"

ADJACENT BUILDING

3'-0"

7'-7" 7'-5" 5" 2'-1" 1'-10" 5'-6"

GAS METER

5'-2"

ADJACENT BUILDING

WOOD COLUMN

OFFICE

3'-11"

EXIST. HWH

11'-11"

10'-1"

2'-0"

50'-5"

EXIST. BOILER

ADJACENT BUILDING

50'-5"

UP

WOOD COLUMN

15'-10"

H=5'-5" - 5'-10"

WALKING CLOSET

5"

7'-0" DN

2'-8" 3'-0"

WOOD COLUMN

EXIST LAV.

HALLWAY

CL.

2'-9"

WOOD COLUMN

SEWER RISER

27'-0"

24' - 11"

24'-11"

EL. METER

H=8'-2"

PROPERTY LINE 50'-5"

WOOD COLUMN

3'-2"

EXIST. TOILET

100'-11" PROPERTY LINE 100'-11"

PROPERTY LINE 50'-5"

17'-2"

2'-11" 3'-0"

10"

PROPERTY LINE 20'-0"

EXIST LAV.

CL.

WOOD COLUMN EL. PANEL

CL.

4'-0"

WOOD COLUMN

DEMOLISION PLANS

SHEET #:

DM-001.00 PAGES:

DATE:

05/01/2017 PARTITION TO BE DEMOLISHED ARCHITECT SIGN & SEAL

4'-0"

EXISTING WALL, EXISTING PARTITION

20'

20'

METAL FENCE

20'

20'

PROPERTY LINE 20'-0"

PROPERTY LINE 20'-0"

METAL GATES

PROPERTY LINE 20'-0"

DATE

10'

PROPERTY LINE 20'-0" 1'-0"

2'-4"

6'-45/8"

WOOD COLUMN WOOD COLUMN

10'

PROPERTY LINE 20'-0"

1'-9"2'-6"

8'-8"

H=7'-7"

DESCRIPTION

6"

9'-9"

13'-11"

3'-9"

H=5'-5"

1'-0"

3'-4"

3'-3"

PROPERTY LINE 20'-0"

10'

4'-11"

2'-11"

H(above floor)=3'-9"

10'

10'-8"

REV. #

PROPERTY LINE 20'-0"

2 OF 6


CITISCAPE

Architectural Consulting

352 EAST 119 STREET Manhattan, NY 10035

05/01/2017


GENERAL NOTES

PROPERTY DATA:

PLOT PLAN

1. SCOPE OF WORK: NEW ONE FAMILY TWO STORY BUILDING.

10' - 0"

10' - 0"

3. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY GOVERNING NEW YORK CITY AGENCIES.

Architectural Consulting

BOROUGH: MANHATTAN

ZONING DISTRICT: R7A/R7X

TAX BLOCK №: 1795

COMMERCIAL OVERLAY: C1-5

TAX LOT №: 32

SPECIAL REGUALTIONS: QUALITY HOUSING PROGRAM

4. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT.

LOT AREA = LOT PORTION R7A (WIDTH X DEPTH) + LOT PORTION R7X (WIDTH + DEPTH) = = 100.92 FT X 10.00 FT + 50.42 FT X 10.00 FT = 1009.2 SQ.FT + 504.2 SQ.FT= 1513.4 SQ.FT

5. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS.

CONDITIONS FOR APPLICATION OF USE REGULATIONS TO ENTIRE ZONING LOT: PERCANTAGE OF LOT PORTION IN R7A DISTRICT: 1000/1513.2*100=66% >50% AS PER ZR.77-11, THEREFORE R7A USE REGULATIONS APPLY TO THE ENTIRE LOT

43' - 9"

EXIST. CONCRETE BLOCK WALL 6'-0" TALL

PROPERTY LINE 50'-6"

8. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.) 9. PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS. 10. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. 11. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED.

PLAN EXAMINERS SIGN & SEAL :

GRASS 311 SQ.FT

FEMA MAP: 3604970091G

MAX PERMITTED FLOOR AREA = 6,053.6 SQ.FT PROPOSED FLOOR AREA

TOTAL ZONING FLOOR AREA

PROPOSED FLOOR AREA RATIO

CELLAR

-

-

NO HABITABLE

NO HABITABLE

1ST FLOOR

728.1 SQ.FT

883.0 SQ.FT

0.58

2ND FLOOR

576.7 SQ.FT

983.0 SQ.FT

-

983.0 SQ.FT

0.65

3RD FLOOR

576.7 SQ.FT

983.0 SQ.FT

-

983.0 SQ.FT

0.65

4TH FLOOR

-

983.0 SQ.FT

-

983.0 SQ.FT

0.65

PENTHOUSE FLOOR

-

983.0 SQ.FT

-

323.0 SQ.FT

0.39

DEDUCTIONS -

133.0 SQ.FT (COMMERCIAL) 850.0 SQ.FT (RESIDENTIAL)

100 SQ.FT (ENTRY WAY) Z.R. 28-11

6' - 9"

13. CERAMIC TILE FOR DETECTABLE WARNING SURFACE SHALL BE PROVIDED AT THE TOP OF ALL STAIR RUNS.

TOTAL

9. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. 10. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. 11. THE CONTRACTOR, UPON COMPLETION OF THE WORK, SHALL APPLY FOR DEPARTMENT OF BUILDINGS INSPECTIONS AND SIGN-OFFS AS REQUIRED.

4,424.6 SQ.FT

2.92

ZONING CALCULATIONS DESIGN FLOOD ELEVATION CALCULATIONS:

PERMITTED <

6,053.6 SQ.FT

FLOOD HAZARD AREA: ZONE AE (EL 12)

OCCUPANCY GROUP: R2 USE GROUP: 1 CONSTRUCTION TYPE: IA

REAR YARD ACCESS NOTES

REV. #

MAXIMUM PERMITTED LOT COVERAGE = 65% (1,513.4 X 0.65 = 983.7 SQ.FT )

THEREFORE OK

PROPOSED LOT COVERAGE = 983.0 SQ.FT,

THEREFORE OK

983.0 SQ.FT/1,513.4 X 100 = 64.95% < 65%

PROJECT NUMBER:

BASE PLANE ELEVATION CALCULATIONS:

M-42 352 EAST 119 STREET, MANHATTAN, NY OPEN SPACE RATIO

STREET WALL ELEVATIONS 10.53' & 10.61'

MINIMUM REQUIRED OPEN SPACE AREA: =

KEY PLAN

MIN. REQ. OPEN SPACE RATIO: 16.5

HEIGHT FACTOR = 3 ( 4,424.6 / 1,513.4 = 2.92 )

BASE PLANE ELEVATION = (SUMM OF STREET WALL ELEVATIONS) / 2

LOT AREA X O.165 = 1,513.6 SQ.FT x 16.5 = 249.7 SQ.FT BASE PLANE ELEVATION = (10.53' + 10.61') / 2 = 10.57'

PROPOSED OPEN SPACE AREA =

LOT AREA - LOT COVERAGE = 1,513.4 - 983 = 530.4 SQ.FT

PROPOSED OPEN SPACE RATIO =

PROPOSED OPEN SPACE AREA / LOT AREA = 530.4 / 1,513.4= 0.35

Z.R. 26-41 STREET TREE PLANTING CALCULATION

PROPOSED OPEN SPACE AREA > MINIMUM REQUIRED OPEN SPACE AREA 530.4 SQ.FT > 249.7 SQ.FT

IN ACCORDANCE WITH APPLICABILITY REQUIREMENTS OF UNDERLYING DISTRICT REGULATIONS, ONE STREET TREE, PRE-EXISTING OR NEWLY PLANTED, SHALL BE PROVIDED FOR EVERY 25 FEET OF STREET FRONTAGE OF THE ZONING LOT. FRACTIONS EQUAL TO OR GREATER THAN ONE-HALF RESULTING FROM THIS CALCULATION SHALL BE CONSIDERED TO BE ONE TREE. SUCH TREES SHALL BE PLANTED AT APPROXIMATELY EQUAL INTERVALS ALONG THE ENTIRE LENGTH OF THE CURB OF THE STREET ADJACENT TO THE ZONING LOT.

THEREFORE OK

PROPOSED OPEN SPACE RATIO > MINIMUM REQUIRED OPEN SPACE RATIO 0.35 > 0.165

THEREFORE OK

STRETT FRONTAGE = 20'-0" REQUIRED NUMBERS OF TREES = 20'-0"/25'-0" = 0.8= 1

BASIC YARD REGULATIONS: BASIC YARD

Z.R. SECTION

REQUIRED YARD

EXISTING

FRONT YARD

Z.R. 23-45

0'-0"

18'-9"

0'-0"

NUMBER OF EXISTING TREES = 1 NUMBER OF PROPOSED TREES (OFF-SITE) = 1 NUMBER OF PROPOSED TREES (ON-SITE) = 0

SIDE YARD LEFT

Z.R. 23-46

0'-0"

0'-0"

1 = 1, THEREFORE COMPLY

SIDE YARD RIGHT

Z.R. 23-462(C)

0'-0" OR 8'-0" IF ANY OPEN AREA

REAR YARD REAR YARD ON SHALLOW PORTION

FILING NUMBER:

BIS BAR CODE STICKER:

30'-0" 10'-0"

Z.R. 23-47 Z.R. 23-52

PROPOSED YARD

40'-8"

43'-8"

CONSTRUCTION CLASS

MAXIMUM HEIGHT OF WALLS AND REQUIRED SETBACK: PARAMETER

Z.R. SECTION

REQUIRED

EXISTING

PROPOSED

STREET WALL HEIGHT

Z.R. 23-662

MIN. BASE: 30'-0"; MAX 65'-0"

35'-0"

52'-5"

MAXIMUM BUILDING HEIGHT

Z.R. 23-662

MAX 80'-0"

35'-0"

60'-5"

SHEET TITLE:

ZONING ANALYSIS

NOTES: 1. BC 1018.1 PROPOSED FIRE RESISTANCE RATING IN ALL CORRIDORS AND STAIRWAYS AT ALL FLOORS - 2 HR. (2 LAYERS GYPSUM BOARDS.) SEE DWG A-101.00, 2 HR. F.R. PARTITION #2. 2. B.C. 1022.1. PROPOSED INTERIOR EXIT STAIR ENCLOSED AT THE TOP AND BOTTOM WITH THE REQUIRED FIRE BARRIER WITH FIRE-RESISTANCE RATING 2 HFR. (2 LAYERS GYPSUM BOARDS.)

ZONING DISTRICT R7X COMMERCIAL OVERLAY C1-5

ENTRANCE (RESIDENTIAL 1ST FL)

10' - 0"

SHEET #:

OFF-STREET PARKING ANALYSIS:

Z-001.00 PAGES:

DATE:

05/01/2017

Z.R. 25-241 PARKING REDUCED REQUIREMENT (RESIDENTIAL)

DN

PROPERTY LINE 20'-0" 18' - 9"

EXCEPTIONS: NO SUCH PASSAGE SHALL BE REQUIRED FOR: 1. BUILDINGS OF TYPE IA OR IB CONSTRUCTION.

GRASS 9.9 SQ.FT

ENTRANCE (RETAIL 1ST FL)

DATE

BASE FLOOD ELEAVTION (BFE) = 12'-0" DESIGN FLOOD ELEVATION (DFE) = 12'-0" + 1'-0" = 13'-0"

DN 1206.2.1 REAR YARD ACCESS FOR MULTIPLE DWELLINGS FOR MULTIPLE DWELLINGS, THERE SHALL BE DIRECT ACCESS FROM THE STREET TO EVERY REAR YARD THROUGH A NONCOMBUSTIBLE 2-HOUR FIRE-RESISTANCE-RATED PASSAGE EITHER IN A DIRECT LINE OR THROUGH A COURT, EXCEPT THAT THE PASSAGE MAY BE 1-HOUR FIRE-RESISTANCE-RATED FOR DWELLINGS NOT EXCEEDING THREE STORIES IN HEIGHT AND OCCUPIED BY NOT MORE THAN TWO FAMILIES ON ANY STORY. SUCH PASSAGE SHALL BE AT LEAST 36 INCHES (914 MM) IN CLEAR WIDTH AND 7 FEET (2134 MM) IN HEIGHT, HOWEVER:

DESCRIPTION

AS PER BC-2014 APPENDIX G, TABLE 4,1: STRUCTURAL OCCUPANCY CATEGORY: II MINIMUM ELEVATION OF LOWEST FLOOR: DFE = BFE + 1'-0"

LOT COVERAGE AS PER Z.R. 23-153

ADJACENT BUILDING

BLOCK: 1575 LOT: 32 ZONING DISTRICT: R7A/R7X ZONING MAP: 6B BIN #3246266

ADJACENT BUILDING

8. PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND REQUIRED SIGN-OFFS.

352 EAST 119 STREET

THEREFORE COMLY Z.R. 23-151

40' - 5"

7. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL DIMENTIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.)

PROPERTY LINE 100'-11"

PROPERTY LINE 50'-5"

PROPOSED MULTI-FAMILY 4-STOREY WITH A PENTHOUSE RESIDENTIAL BUILDING 352 EAST 119 STR, MANHATTAN, NY, 10035

50' - 5"

5. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTORITIES AND BUILDING MANAGEMENT.

490.4 SQ.FT

PROPOSED

GRASS 99.8 SQ.FT

10' - 0"

4. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS.

4,915 SQ.FT

TOTAL: 4,424.6 SQ.FT PERMITTED F.A.R. = 4.00 PROPOSED F.A.R = 4,424.6 / 1,513.4 = 2.92 2.92 < 4.00, THEREFORE OK

ENTRANCE (1ST FL)

3. THE CONSTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT.

2,224. SQ.FT

100' - 11"

100' - 11"

BUILDING DEPARTMENT NOTES

2. BEFORE COMMENCING WORK, THE CONSTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH THE DEPARTMENT OF BUILDING, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL FEES REQUIRED BY GOVERNING NEW YORK CITY AGENCIES.

PROJECT TITLE

Manhattan, NY 10035

PROPERTY LINE 20'-0"

1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODE, FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES.

DOB PERFORATION :

(ANY ADDITIONAL INCREASE IN F.A.R. SHALL BE INCLUDED WITH THE PROPER ZONING SECTION AND SHALL BE REFLECTED IN TOTAL F.A.R. CALCULATION)

EXISTING FLOOR AREA

FLOOR LEVEL

ENTRANCE (1ST FL)

14. TACTILE WARNING SHALL BE PROVIDED AT ALL HAZARDOUS LOCATIONS ON FLOORS, DOORS, STAIRS, ETC AND SHALL COMPLY WITH APPLICABLE REQUIREMENTS SET FORTH IN RS 4-6.

SITE

MAXIMUM PERMITTED COMMERCIAL F.A.R. = 2.0 WITHIN COMMERCIAL OVERLAY C1-5 AREA OF LOT PORTION WITHIN COMMERCIAL OVERLAY C1-5: 50.42 FT X 10.00 FT = 504.2 SQ.FT MAX COMMERCIAL F.A. = 1008,4 SQ.FT

12. UNISEX HANDICAP BATH ROOM:SIZE: LETTERING 1.5" STROKE 1/8", RED LETTERS ON WHITE BACKGROUND PLEXI GLASS 1/8" THICK W/TEMPER PROOF SCREWS.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORTING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK.

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

MAIMUM PERMITTED F.A.R. FOR RESIDENTIAL = 4.0 AS PER SECTION Z.R.23-153 LOT AREA X MAX F.A.R. = TOTAL MAX. F.A 1513.4 SQ.FT X 4.0 = 6,053.6 SQ.FT

50' - 6"

7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK.

CITISCAPE

ZONING ANALYSIS:

EXISTING TREES

6. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING MANAGEMENT.

TAX MAP

ADRESS: 352 EAST 119 STREET, MANHATTAN, NY, 10035

PROPERTY LINE 20'-0"

2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODE, FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES.

ZONING MAP: 6b

ZONING DISTRICT R7A

10' - 0"

ARCHITECT SIGN & SEAL

LESS THAN 10,000 SF LOT AREA = 30% OF DWELLING UNITS; 30% OF 7 UNITS = 2.0 PARKING SPACES REQUIRED

3' - 0"

Z.R. 25-261 MAXIMUM NUMBER OF ACCESSORY OFF-STREET PARKING SPACES FOR WHICH REQUIREMENTS ARE WAIVED IN R7A ZONING - 15 PARKING SPACES.

PROPOSED NEW TREE

THEREFORE, REQUIRED 2 PARKING SPACES (Z.R. 25-241) MAY BE WAIVED.

ZONING DISTRICTS BOUNDARY

EAST 119 STREET ( WIDE )

COMPLIANCE

NYCBC SECTION BC 310

OCCUPANCY GROUP R-2 RESIDENTIAL

COMPLY

BC 503

CONSTRUCTION TYPE PROPOSED: I-A

COMPLY

1 OF 6


CITISCAPE

Architectural Consulting

352 EAST 119 STREET Manhattan, NY 10035

1400 AVENUE Z SUITE 302 BROOKLYN, NY 11235 WWW.CITISCAPEUSA.COM INFO@CITISCAPEUSA.COM TF. 718.554.1741

05/01/2017