Summary

Structure Tech Home Inspections 4205 Raleigh Avenue South Saint Louis Park, MN 55416 www.StructureTech1.com 612-205-5600 Customer Experienced Home Buyer Address 12345 Happy Lane Minneapolis MN This Summary Report includes the items that were, in my opinion, the most important items to bring to your attention. This is not by any means a substitute for the full report. Please read the entire report.

3. Exterior 3.3

Windows (1) The windows at the back of the house indicated in the photos below were rotted and should be replaced. (2) The window at the back of the house indicated in the photo below was beginning to rot at the bottom corners of the mullion, and should be serviced to help forestall further deterioration.

5. Electrical 5.1

Interior Panel Components (3) The circuit breaker at space #18, labeled "upstairs bathroom", supplied power to the upper hallway bathroom, the master bathroom, upper hallway lights, upper den (piano room) lights and outlets, and most of the recessed lights at the west basement family room. This circuit is overloaded, and it tripped several times during the inspection. Have an electrician correct the wiring. Because the main panel was filled to capacity, the fix for this condition might require the installation of a subpanel.

Licensed To Reuben Saltzman