SERVO MOTOR
1
XXXXXXX.9663.02400
• Geared d.c. actuator motor with feedback potentiometer for swivel motion of up to 180° for the adjustment of Buschjost heating valves and ventilation flaps in commercial vehicles.
Technical Data
Materials
Gearing: Irreversible
Housing: Polybutylenterephthalat (PBT)
A C T U A TOR S
• Type approval EMV E1 10R-036112
Mounting position: Actuator vertical on top ±90° Other mounting positions by appointment Direction of rotation: Right/left
Kraft
fahrt DE-24
Rotation angle drive shaft: 183° ±3°
E1
-Bun
932
Flensb
desam
t
urg
MITTE ausges
ILUNG
tellt von
:
Kraftfa
hrt-Bu über die Erw ndesa eines eite mt Regel Typs ein rung der es ung Nr. 10 elektrischGenehmig en/ele ung ktronis chen
Rated speed: 5,5 ± 2 min -1
COMM issued
UNICA
by:
TION
Bauteil
es nac
h der
Kraftfa
hrt
concer -Bund nin esamt of a typ g app Regul e of ele roval ext end ctri ation No. 10 cal/electro ed nic sub -as
Numm Approv er der Ge nehmig al No .: ung
Rated torque: 0,4 Nm
1.
2.
Ausfüh Versio rung(en): 9663.0 n(s): 9672.0 2400 9671.0 2400 9663.0 2400 1200 Hande Gener lsbezeich Stellm al comme nung(en): rcial otor descrip tion
Start-up torque: 100 ... 350 Ncm
: 036
112
Fabrikm Make arke (Ha Busch(trade nam ndelsnam Spher jost Gm e of ma e des He nufact os Gm bH rsteller urer): s): bH Typ: Type: 9663
sembly
with
regard
to
Erweite Extens rung Nr. ion No : 02 .:
(s):
Load drive shaft, static: Holding torque max. 15 Nm at room temperature axial force 30 N radial force 50 N Limit stops: Fitted to housing, unsprung Mass: 0,125 kg
63
Installation: Ø bolthead ≥8,5 mm ≤11 mm clamping force 1 kN / bolt Temperature range: -40 ... +110°C
Plug connector: See connection table
Short-circuit current: ≤250 mA
Type of protection: IP 6K9K with suitable power outlet (see connection table)
Control pulse length: ≥65 ms
Reverse polarity protection: All connections on vehicle protected against reverse polarity (max. 28 V, max. 60 sec) to ground and positive operating voltage except for slider connection.
Busy period: ≤30 s
Rated voltage: 24 V d.c.
Overall busy period: ≤200 h, 144.000 limit stops, 90° swivel angle, activation 7.5 sec, pause 30 sec
Operating voltage: 18 ... 32 V d.c. Rated current: ≤100 mA
Electrostatic discharge (ESD): No interferrence (passive components only) Interference immunity: intensity level 3, for ECE-scheme No. 10 Emitted interference: According ECE-Scheme No. 10
No-load current: ≤50 mA
Diagram 250
9 n
U p= 26V
P2
I
P2 [W]
8
200
0,335
7
0,3
I [mA]
5 4
100
n [min-1]
6 150
0,2
3 2
50
0,1
1 0
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
0
0
M [Nm]
For further information, visit store.norgren.com and use the new improved search function. If you cannot see the option you require please contact us.
Online at store.norgren.com
Electrical features