b!design SPC 4,2/0,3 mm + 4,8/0,5 mm I4F with no footstep soundproofing

Page 1

LAYING INSTRUCTIONS SPC 4,2/0,3 mm + 4,8/0,5 mm I4F with no footstep soundproofing bdesign-floors.com
2 Contents Important installation tips 3 10 tips for laying perfect floors 4 Basic rules for laying 5 General requirements for the base layers 6 Underlay materials 10 Conservatories at home 12 Hints for laying 13 SPC 4,2/0,3 mm + 4,8/0,5 mm 15 I4F with no footstep soundproofing Accessories 22 Underlay materials Installation materials Cleaning and care 25 General information on cleaning of LVT and SPC floor coverings General information on cleaning of ecological floors b!design detergents Warranty conditions 32 Summary of contents

IMPORTANT INSTALLATION TIPS

Ideal temperature

SPC: 15-60 ° C

vinyl/susify: 13-32 ° C

Surface temperature

no more than 60 °C for SPC floors and no more than 32 °C for vinyl/susify floors

Acclimatisation

Vinyl/susify for 48 hours

SPC and Multilayer + for 24  hours

Air humidity between 35 % – 60 %

Base layer level tolerance 3 mm over 1.8 m

Underfloor heating

Water-based underfloor heating systems must lie at least 13 mm in the substrate. Electric underfloor heating systems are to be classified as suitable to a limited extent.

Edge clearance

> 8 mm clearance on walls and around heavy, fixed objects, wall cupboards, kitchens etc.

Adhesive

The design floor coverings with click system are designed for floating installation. Gluing them down voids all warranty claims.

Underlay materials

On mineral substrates and with design floor coverings with integrated underlay mat, a moisture protection foil SD ≥ 75m must always be applied over the entire surface and in the form of a trough. The joints between the tiles must be be leveled

Underlay mat

It is generally recommended to use an underlay mat. We recommend the DBCover underlay mat for the installation of our floors.

The underlay mat must fulfill the following values:

• Max. Thickness: 1.5 mm

• CS value: > 500 kPa

• Density: > 800 kg/m3

• No sticky, adhesive or anti-slip surface

For floors with an integrated underlay mat, no additional underlay mat may be laid.

3 Important installation tips

10 tips for laying perfect floors

1. Any flooring that has been purchased should be checked for defects before installation. This stops defective products being used. The guarantee may be invalidated if the floor covering is fitted anyway.

2. Only install on solid, non-floating base layers.

3. Do not install fixed fixtures such as kitchen units, built-in cupboards, washing machines or similar on the installed design flooring. The design flooring must be decoupled using an expansion joint.

4. Use office chairs with soft castors TYPE W in accordance with DIN 68131 on design floors. We also strongly recommend the use of suitable floor protection mats.

5. Always follow the manufacturer’s instructions.

6. Buy the recommended footstep soundproofing for the floor. Carpet is NOT a permitted insulation.

7. Use spacers as you work so that the floor lies straight and does not slip during installation.

8. Keep the recommended offset of 30 cm to the joints in adjacent rows. This provides maximum stability for the connection.

9. Joints can be sealed using PE cord and silicone to prevent cracks from forming. To avoid complaints, it is recommended that if a joint has to be filled, it is important to ensure that a) silicone is used. b) the dimension of the joint is widened by 50%. and c) a joint cord is used to prevent the silicone from sticking to the base.

10. Unless otherwise specified in the installation the specifications of the DIN and SIA standards apply. The specifications of the MMFA and the rules of the trade must also be observed.

4 10 tips for laying perfect floors

Basic rules for laying

USEFUL INFORMATION

Vinyl / SPC / susify is hardwearing, healthy to live with and extremely easy to clean - ideal for use in a wide variety of areas of the home. The large selection of patterns, formats and surface structures lets you create your own completely unique interior design: With contemporary looks and an authentic feel for a homely and pleasant atmosphere.

SERVICE CLASSES

Its properties, requirements and test methods are defined under European standards for vinyl/ SPC/susify flooring. These are presented simply and transparently using the service classes. Depending on the results obtained – in line with the requirements and the load/usage intensity – the flooring is assigned to the classes for private use (around 20), commercial/public use (around 30) or industrial use (around 40).

5 Basic rules for laying
Service classes in private areas Service class Pictogram Load intensity Area of application (e.g.) 21 moderate use Bedrooms, storage rooms 22 normal use Living rooms, dining rooms 22+ normal use as 22, but with heavier use 23 heavy use Kitchen, hallway Service classes in the commercial sector Service class Pictogram Load intensity Area of application (e.g.) 31 moderate use Hotel rooms, small offices 32 normal use Offices, hotel corridors 33 heavy use Classrooms, large offices, clothes shops 34 intensive use as 33 but with increased requirements Service classes in the industrial sector Service class Pictogram Load intensity Area of application (e.g.) 41 moderate use Precision mechanics/electronics workshops with light vehicular traffic 42 normal use Storage areas or workshop areas where there is moderate use 43 heavy use Storage areas or production halls

General requirements for the base layers

As a general rule and as part of their requirement to carry out an inspection and due diligence, the contractor for flooring work or the private individual laying their own flooring must be reasonably satisfied that the base is ready for laying before the flooring is laid. The following points in particular must be taken into account when assessing whether these floors are ready to be laid. Failure to comply with these will render any claims under the guarantee or warranty void.

CHECKING THE MOISTURE LEVEL IN THE BASE LAYER:

The test is conducted using a CM device. The following limit values must not be exceeded:

• For cement screeds ≤ 2 CM % – heated screeds ≤ 1.8 CM %

• For calcium sulphate screeds / calcium sulphate flowing screeds ≤ 0.5 CM % – heated screeds ≤ 0.3 CM %

These values apply to screeds that do not have any admixtures. When using admixtures or fast-drying screeds, the measurements and limits specified by the respective manufacturer must be observed. The test sample must be taken from the lower third of the screed. The thickness of the screed must also be measured and recorded.

CHECKING THAT THE BASE LAYER IS EVEN:

Refer to the current standards when checking that the base layer is even. To do this, place a measuring rod or straight edge on the highest points of the surface. This is how you determine the depth at the deepest point in relation to the supporting surfaces (measurement intervals). With a measurement interval of 180 cm, the vertical deviation must not exceed 3 mm. Larger deviations should be compensated for by taking appropriate action, e.g. by using self-levelling compounds.

Please take care not to exceed or fall below the ideal humidity value shown in the diagram over the course of the year.

6 General requirements for the base layers
Living area climate over the year Air humidity in % Too humid Too dry Ideal value 35-60 % Mar Jan Feb Apr May Jun Jul Aug Sep Oct Nov Dec

CHECKING THE LOAD BEARING CAPACITY OF THE BASE LAYER:

The base layer must be a closed self-supporting layer.

CHECKING THAT THE BASE LAYER IS CLEAN:

The base layer must have been vacuumed beforehand.

CHECKING THE AMBIENT CLIMATIC CONDITIONS:

The following conditions must be met before, during and after installation:

• an indoor room temperature of at least 18 °C

• a ground surface temperature of at least 15 °C

• relative humidity between 35 % – 60 %

When laying floors using a floating installation, any of the base layers can be used if they meet the requirements listed above. This includes in particular:

• all types of screed, including hot water-based heating screeds

• Chipboard constructions

• Fibreboard

• Existing floor coverings such as PVC, linoleum, natural stone slabs and ceramic tiles

Unsuitable base layers:

As a general rule, designer flooring may only be installed on solid, non-floating base layers. Failure to comply with these will render any claims under the guarantee or warranty void.

The maximum surface temperature of 60 °C for SPC flooring and of 32 °C for vinyl/susify flooring must not be exceeded. In addition, a very rapid heating sequence must be avoided.

7 General requirements for the base layers
Ideal temperature

PLEASE NOTE

In each case, temperatures in the area of the installed surface must be typical for living areas throughout the year.

We recommend heating the affected rooms in winter and protecting them from direct sunlight or darkening them in summer by taking appropriate precautions (e.g. roller blinds or venetian blinds).

If these recommendations and regulations are not complied with, any guarantee or warranty claims on the part of HWZI are excluded.

The following are regarded as base layers with limited suitability:

• Electrically operated underfloor heating systems (controlled surface temperature)

Electric underfloor heating systems are classified as base layers with limited suitability. This is because a number of foil-based, electric heating systems can generate surface temperatures much higher than 28 °C. Approval will be given for an electrically operated underfloor heating system: If this can be controlled digitally and there is a guarantee that the surface temperature never exceeds 28° C. In addition, technical approval for designer floors must be given by the manufacturer of the heating system. There is NO guarantee for products that are installed on infrared underfloor heating.

Screeds / concrete bases

When laying floating designer flooring on screeds, please note that rising damp must be expected.

Accordingly, prior to the installation of a systemrelated insulation underlay, all screeds (with the exception of mastic asphalt) must have (see point: Caution! underlay materials) a moisture protection foil SD value ≥ 75 m must be installed as a vapour barrier over the entire surface and in the form of a tray, if the underlay mat does not offer an equivalent function. When properly installed by a professional, the sheets of moisture protection film must overlap by 5 - 20 cm in the joint area, depending on the design. If no underlay mat is being used, the moisture protection foil should still be used for decoupling under the designer flooring.

Screeds with hot water underfloor heating

When installing a heated floor construction, all parties involved (builder, architect, heating planner, heating contractor, installer, flooring manufacturer) must work in coordination with each other. Every surface-heated floor requires use-related planning and coordination with regard to the heating system and the screed. This is to ensure that there is no damage and the best possible functionality over the long term. In addition to the usual tests of the installation's base layer, the underfloor heating or cooling system must be tested for functionality (functional heating or cooling). This proof of proper heating and cooling of the screed construction must be provided at all times of the year and documented in a heating and cooling log.

DIN EN 1264-2

EN 1264-2 specifies the framework conditions and the test for determining the performance of hot water underfloor heating systems as a function of the difference between the heating medium temperature and the room temperature. The heat output is checked by calculation and by taking measurements.

8 General requirements for the base layers

When heating the load or heat distribution layer, a distinction is made between functional heating and heating for readiness for covering.

• The functional heating is the heating contractor's proof of the provision of non-defective workmanship. It also serves to check the functional efficiency of the heated floor construction.

• Heating for readiness for covering is the process of driving out the residual moisture in the screed until it is ready for covering.

PLEASE NOTE

Functional heating does not ensure that the screed has reached the residual moisture required for readiness for covering. As a result, heating to readiness for covering is usually required.

Natural stone and ceramic tiles

Residual moisture must be expected to rise and, accordingly, before the system-related insulation underlay (see point: Caution! underlay materials) a moisture protection foil SD value ≥ 75 m must be installed as a vapour barrier over the entire surface and in the form of a tray. If footstep soundproofing is laminated on the back of the design floor, you must not lay any further insulation underlay. The joints of the tiles must be leveled before laying.

OSB, chipboard and fibreboard

To improve the footstep soundproofing, lay a system-appropriate insulating underlay before installing designer flooring (see point: Caution! underlay materials). If no underlay mat is being used or if you are installing a floor covering with an

integrated underlay mat, a 0.2 mm PE construction foil should be installed for decoupling purposes.

Wooden floorboards

Any loose panels should be properly screwed in place. To improve the footstep soundproofing, lay system-appropriate insulation underlay before installing the designer flooring (see point: Caution! underlay materials). If no underlay mat is being used or if you are installing a floor covering with an integrated underlay mat, a 0.2 mm PE construction foil should be installed for decoupling purposes.

Elastic floor coverings (PVC, linoleum, vinyl)

These floor coverings do not require a moisture protection film. As this elastic floor covering acts in the same way as the vapour barrier. To improve the footstep soundproofing, lay a system-related insulation underlay before installing the designer flooring. If no underlay mat is used or if you are laying a floor covering with an integrated underlay mat, a 0.2 mm PE construction foil should be installed for decoupling. (see point: Attention! Underlay materials)

Wet rooms / damp rooms

You can even install designer flooring in damp rooms – with the exception of saunas. Failure to comply with these will render any claims under the guarantee or warranty void.

DIN 18365

The DIN 18365 standard for "floor covering work" applies to the laying of floor coverings in sheets and tiles made of linoleum, plastic, elastomer, textiles and cork as well as to the laying of multi-layer elements.

9 General requirements for the base layers

Underlay materials

The correct base layer is crucial when laying floor coverings. This is why we recommend that an underlay mat is used. If this is not used and therefore the specifications for the base for the floor are not fulfilled, the guarantee will be invalidated. The following values are crucial here:

DL: SPECIFICATIONS FOR DYNAMIC STRESS

Dynamic stress (DL) is created when people walk around in a room and also when chairs are used. In such cases, the underlay must be able to withstand short-term loads without changing its properties in the long term. This ability is expressed by the DL value. The higher the DL value, the longer the underlay will withstand dynamic demands. A DL value of 10,000 cycles is recommended. For increased stress, the DL value should be at least 100,000 cycles.

CS, CC AND PC: SPECIFICATIONS FOR STATIC STRESS

The CS and CC values define the requirements for static loading. This is created when the floor covering is permanently loaded by fixed, heavy furniture. The underlay should be able to withstand very high static loads without giving way an excessive amount. A high CS value is important to maximise the service life of the click connections. The underlay must not give too much so that the floor covering is protected from deformation and damage due to vertical movement. The CS value

must be greater than 500 kPa. This means that the higher the CS value, the better the protection against this damage. In terms of longterm exposure, the CC value is an important factor. Heavy pieces of furniture that are in a permanent location on the floor subject the floor to constant stress. The CC value is used to evaluate how the underlay behaves over a load period of 10 years. For increased requirements, the CC value should be at least 20 kPa. In addition, the underlay mat should not exceed a point levelling capacity (PC) of up to 0.5 mm at a thickness of 1.5 mm.

WHY ARE UNDERLAYS NEEDED WHEN LAYING FLOORING?

An underlay only makes sense if it also contributes to the quality of the flooring system. The underlay represents the connection of the floor to the base layer and must therefore meet certain requirements. Most importantly, this includes clearing up any unevenness in the base layer. The floor is protected from everyday wear and tear and also from residual moisture. In addition to footstep soundproofing and walking comfort, thermal insulation is also an important factor.

10 Underlay materials

WE RECOMMEND THE DB COVER UNDERLAY MAT WHEN LAYING OUR FLOORING:

An outstanding feature of the elastic footstep soundproofing underlay is the unique reduction in the walking noise from footsteps. The DB Cover is produced using state-of-the-art technology from recyclable and renewable raw materials and is the ideal insulating underlay for designer flooring. The compressive strength of the DB Cover underlay mat is particularly remarkable. Its CS value of 1677 kPa is significantly higher than conventional underlay mats. It is easy to handle and install. The underlay mat is a winner twice over thanks to its long service life and its maintenance-free design. The icing in the cake is the fact that these advantages are complemented by its excellent value for money. With designer flooring the insulation underlay is laid with the white textile side facing upwards.

11
Underlay materials

Conservatories at home

A residential conservatory is a conservatory that is intended for use as a living area throughout the year and therefore also for use at comfortable temperatures (more than 19 °C). This means that the temperature cannot drop below 15 °C even in the winter. Solar heating in summer is limited by natural shading and/or design elements such as ventilation, appropriate glazing and solar shading depending on local conditions and the direction the conservatory faces, so as to avoid excessive temperature fluctuations at ground level. The indoor climatic conditions must be accounted for:

• Climate during laying: The indoor air temperature should be 20 °C (at least 15 °C), relative air humidity between 35 % and 60 %

• Permanent living climate: The indoor air temperature should be between 18 °C and 22 °C, relative air humidity between 35 % and 60 %

The surface temperature of the floor must not exceed 32 °C for vinyl/susify flooring or 60 °C for SPC floor coverings.

The installation can only be carried out on a base layer that meets the specifications of DIN 18356 "Parquet floorboards" and DIN 18365 "Floor covering work".

• The construction is permanently protected against rising damp from the ground.

• The substructure should be insulated in such a way that damage due to temperature differences or condensation cannot occur.

• In the case of screeds, the residual moisture values must be checked using a CM meter before laying and should be adhered to strictly:

• Cement coating heated/unheated: 1.8 CM% / 2.0 CM%

• Calcium sulphate screed heated/unheated: 0.5 CM% / 0.5 CM%

• The base layer must be checked to ensure that it is ready for the flooring to be laid. In particular, this must be even, dry, non-slip, clean, free of cracks, free of separating agents and resistant to tension and pressure.

If a levelling compound is being applied to the base layer, the prescribed indoor climatic conditions, the required base preparation (sanding, priming, ...) and the drying times must be strictly adhered to.

The packages must be allowed to acclimatise before they are opened. To do this, leave them unopened and flat on the floor for about 48 hours (in winter about 3 - 4 days) in the middle of the room in which you want them to be laid. In the case of full-surface adhesion, the manufacturer's specific requirements (indoor climatic conditions, open time, sufficient adhesive quantity of the suitable adhesive) must be observed. The light fastness of our floors has been tested in accordance with the EN ISO 105-B02 test standard and meets the highest requirements. However, changes in colour due to strong and prolonged exposure to high levels of sunlight cannot be ruled out. The product-specific installation instructions must be observed.

12
Conservatories at home

Hints for laying

KEEP CONNECTING POINTS CLEAN

When installing designer flooring, make sure that the connecting joints are free of dust, dirt and foreign matter. The cleaner the clic system, the better the connection between the panels. It is best to leave the panels in the box until shortly before they are laid.

Please note that long-term continuous temperatures of > 32 °C / < 13 °C for vinyl/susify and > 60 °C / < 15 °C for SPC floor coverings, may damage the floor, especially when combined with direct sunlight.

CHECK THE SURROUNDING AREA AND THE BASE LAYER

The floor layer should raise any concerns noted during their inspection before the floor covering is laid. In particular if:

• there are larger irregularities

• there are cracks in the base layer

• the base layer is not dry enough

• the surface of the base layer is not sufficiently firm, too porous or too rough

• the surface of the base layer is contaminated, e.g. by oil, wax, varnish or paint residues

• the height of the surface of the base in relation to the height of adjoining parts of the building is not correct

• the base layer is not at a suitable temperature

• the indoor climate is not suitable

• there is no heating protocol for heated floor constructions

• the edge insulation strip has no projection

• no measuring points are marked in heated floor constructions

• there is no joint plan

MEASURING THE ROOM

Measure the length and width of the room If the room has any alcoves, then these must be measured separately. This gives you the floor area of the room. Buy at least 10% more to allow for defects, offcuts or replacements. However, this may vary depending on the size and layout of the room. The first thing you should check is that the opposite walls are parallel to each other. If they are not parallel, you can make adjustments to the first row of the floor. Start by laying out a row of loose panels to see if you need to adjust the length of the first panel.

13 Hints for laying

Measure the length of the room and divide it by the panel length so you do not end up with a short piece of less than 30 cm on the opposite wall. If the remaining piece is smaller than 30 cm, calculate half of the remaining piece and shorten the first panel by this length. To do this, take measurements and mark the first panel. Then use a straight edge and a multi-purpose knife to score the panel and break it off.

RECYCLE ANY LEFTOVER PIECES

When cutting vinyl floors to length, always make sure that you cut the short side of the panel with the groove. The leftover piece can then be used on the opposite side of the room at the end of this rowif the arrangement allows this.

GET ANY DAMAGED FLOORING REPLACED

Be sure to have some extra vinyl panels in reserve in case an unforeseen replacement needs to be made. Vinyl panels that have click joints can be removed and replaced with new ones. If you need to replace a vinyl panel, take a multi-purpose knife and simply cut along the long side of the damaged panel and lift it out. Then take a spare panel and cut off the tongue and groove only on the long side of the replacement panel. Leave the tongue and groove at the short end of the panel. Then simply fit in and snap the two short ends into place. If you have any problems or questions, please contact your sales partner.

RANGE OF USE AND APPLICATION

CAUTION: The flooring has been designed for indoor use only. Do not lay the floors over existing carpets, foam underlays or in saunas or solariums.

FLOATING INSTALLATION AND EXPANSION JOINTS

For a floating installation to be successful, the floor covering must be able to move freely on all sides. When laying, ensure that expansion joints are maintained to all fixed parts of the structure in the horizontal plane. Similarly, rooms on passageways or areas with different climates must be separated from each other by expansion joints. Expansion joints in the substructure must comply with the “DIN18560” standard.

14
for laying
Hints
I4F with no footstep soundproofing SPC 4,2/0,3 MM + 4,8/0,5 MM
bdesign-floors.com

SPC 4,2/0,3 mm + 4,8/0,5 mm

RECOMMENDED TOOLS

Universal knife and straight edge

Tape measure

8-10 mm spacers

Pencil

Tapping block

Rubber mallet

Carpenter's angle

Drawbar

PROPERTIES

The flooring incorporates innovative I4F edgelocking technology. Simply hook in, press firmly and lock with a light tap.

The flooring's unique connection points click into place, just like a door lock. Insert a panel at an angle into the long edge of another panel. Then position it so that the front edges are close together, push them together and fold down the short side. Then lock in place with a light tap.

The flooring is easy and quick to install. The panels are not fixed to the floor underneath, but are laid as a floating installation. To shorten a panel, simply score it and break it off.

The flooring is available in panels with surface embossing for a beautiful and stylish room design with a natural wood effect.

The flexibility of the flooring allows the panels to be installed over existing floor coverings, such as natural wood, concrete, vinyl, linoleum and even ceramics. (See Preparing the floor underneath from page 4)

The floor is also suitable for use in conservatories, it is waterproof and can therefore be installed in damp areas such as basements or bathrooms that were previously unsuitable for traditional wood flooring and laminate products. (See Preparing the floor underneath from page 4) In addition, the Strong SPC Structure can be installed in rooms where there may be large variations in temperature. (See TECHNICAL DETAILS, temperature range).

LAYING INSTRUCTIONS

CAUTION: Do not lay the flooring on soft underlays such as carpets or foam mats.

Prepare the floor for laying. Check the products for material or transport damage in daylight before use. If defects (e.g. differences in colour or gloss) are visible during installation, further work must be stopped immediately so that the goods can be inspected or, if necessary, replaced.

16
SPC
no footstep soundproofing
4,2/0,3 mm + 4,8/0,5 mm – I4F with

Later complaints of visible and surface defects, which can be detected before or during the installation, will no longer be accepted! The manufacturer's corresponding warranty obligation shall become null and void.

You should store the flooring horizontally in the room where it will be laid for 24 hours before installation. Maintain a room temperature between 15 °C and 60 °C for SPC floors. Do not remove the panels from the packets during this acclimatisation period. Maintain this temperature during installation (at least 2 days).

PREPARING THE FLOOR UNDERNEATH

Before installing the floor, please observe the general requirements for the base layers.

The floor underneath must be smooth, level, dry, clean and firm. Carpet staples or adhesive residues must be removed to ensure correct installation.

The floor underneath should be level, with a deviation tolerance of 3 mm over a distance of 1.8 m. Any unevenness above this must be sanded down or filled using a floor levelling agent. The flooring cannot be locked correctly if there are cavities or bulges in the floor underneath. Damage to the floor covering may occur with use if the floor covering does not lie fully on the surface.

The base layer must be carefully checked for moisture. The floor is waterproof, but is NOT a vapour barrier. Any problems with humidity must be rectified before installation. Allow new concrete floors to set and dry out for at least 90 days.

If you are laying on concrete, wood or wood-based materials, a 0.2 mm thick PE construction foil must be laid so that the SPC covering is able to move freely.

NEVER lay a floating floor on a floating base layer! This is not considered to be fixed and must be screwed or glued down or removed!

If a footstep soundproofing underlay is desired or required, please refer to the information in the chapter "Underlays".

17
SPC 4,2/0,3 mm + 4,8/0,5 mm – I4F with no footstep soundproofing

LAYING THE FLOORING

1. Flooring should only be laid if it is free of faults

After unpacking, check the panels immediately for damage and defects (e.g. differences in colour or gloss level). Defective panels should not be installed.

3. Underlay mat

We recommend the use of an underlay mat for floors that do not have footstep sound insulation. SPC 4,2/0,3 mm + 4,8/0,5 mm – I4F with no

2. Long end pieces

Measure the room before installing the flooring. The end pieces must be at least 5 cm wide on the long side.

4. Keep spacing in mind

Start the installation on the left-hand side in the corner and with the groove facing the wall. Keep a distance of 8 -10  mm from the edge to compensate for movements of the base.

18
footstep soundproofing

5. At least 30 cm of offset

The short edges (head joints) must always be offset by at least 30 cm from row to row.

6. Lay the first row

The first row (short side) is the Droplock connection, it is hung vertically. When joining the short edges of the first row, slide the face of the second panel over that of the first panel. Make sure that the two grooves are positioned precisely on top of each other. Press the inside in and tap the panel at the seam with a rubber mallet until it clicks into place. Tap from the inner corner where the two panels meet, outwards to the opposite side.

7. Sawn-off end pieces

If the end piece sawn off in the last row is 30 cm or longer, you can use this as the first panel in the next row.

8. Prepare the second row

For the second row, cut the panel to size for the desired installation pattern as desired - but this must not be shorter than 30 cm. Measure the desired length and mark with a pencil. Then score the surface of the panel several times using a universal knife and crease the panel. Now cut through the coating on the underside.

19
SPC 4,2/0,3 mm + 4,8/0,5 mm – I4F with no footstep soundproofing

9. Follow the sequence

1: Long side: Click tongue into groove.

2: Push the short sides together.

3 and 4: Press panel down.

5: Tap down using a rubber mallet.

11. Lay the remaining rows

Continue this pattern for the remaining rows. Always lay the cut side of the shortened planks on the wall side.

10. Lay the third row

Start the third row with a panel that you have cut to two-thirds of the length. The remaining end can again be used at the end of a row - if the floor space permits this.

12. Adjust panels as needed

Fitting around uneven objects is no problem. Use a piece of cardboard to make a pattern of the cut-out around pipes or irregular objects. Draw this pattern on the panel. Using a universal knife, cut along these markings to obtain the required cut-out.

20
SPC 4,2/0,3 mm + 4,8/0,5 mm – I4F with no footstep soundproofing

13. Remove spacers

You only need the spacers at the edge during installation. Remove these once your floor has completely laid.

15. Direct sunlight

The flooring must be protected from direct sunlight. The warranty will become invalid if the temperature is not within the recommended range.

14. Do not lay flooring under objects

Start by placing your furniture in the room and then lay your flooring around the objects – and not underneath.

21
SPC 4,2/0,3 mm + 4,8/0,5 mm – I4F with no footstep soundproofing

bdesign-floors.com

ACCESSORIES Underlay materials assembly materials

Underlay mat LVT/SPC 1.5

We recommend a heat- and sound-insulating underlay made of environmentally friendly latex foam that is stable under pressure. Note on the use of an underlay mat: The underlay mat should be laid on the floor with the textile side facing upwards and the vapour barrier film facing downwards.

• Format 1 x 10 m

• Thickness 1.5 mm

• Increased walking comfort

• Absorbs sound and noise (14 - 18 dB)

• Resistant to pressure (1677 kPa) and highlyelastic

• With an integrated vapour barrier film

• Latex-based

• Manufactured using renewable raw materials

• Suitable for hot water underfloor heating

TECHNICAL DATA

Thickness

EN 1849 - 1 1.5 mm

Specific weight EN 1849 - 1,950 Kg / m3

Footstep sound level UNE 104-B 717/12 14-18 dB

Walking noise level > 38,1 %

Reaction to fire DIN 4102 Bfl-s1

Thermal conductivity EN 12667 0.0091 m2K/w

Suitable for underfloor heating yes

Suitable for chair rollers yes

23 Accessories – Underlay materials

Tapping block

Using a high-quality tapping block makes professional installation even easier! A practical and professional tool for laying floors with click profiles.

As far as click coverings are concerned, the only way to ensure a permanent connection of the individual strips with each other is using friction to interlock the panels. Using a professional tapping block means that you have a professional installation aid for laying floor coverings with a click system. Specifically developed for laying click coverings, it protects the grooves and tongues of the panels with every tap.

24 Accessories – assembly materials

General information on cleaning of LVT and SPC floor coverings

General information on cleaning of ecological floors

b!design detergents

bdesign-floors.com

CLEANING AND CARE

General information on cleaning of LVT and SPC floor coverings

Congratulations! You have finished laying your new flooring. Your new flexible floor covering has been manufactured to the highest quality standards and will give you long-lasting enjoyment. Follow the recommendations in these instructions to keep your floor looking like new and maintain the factory finish.

PREVENTATIVE CARE

1. Use protective mats WITHOUT A LAYER OF RUBBER by doors that lead outside. This stops sand and gravel getting onto your floor. With all floor coverings, coarse-grained sand is public enemy number one.

2. Attach suitable furniture glides (preferably made of felt) to all pieces of furniture that you place on an elastic floor covering. Furniture glides allow chairs to be moved across the floor easily without any scratches or scuffs. Clean the furniture glides regularly to remove dirt that may have accumulated underneath. For swivel chairs and other pieces of furniture on castors, please use 5 cm wide, nonmarking castor feet (type W). Do not use rubber rollers. For office swivel chairs or other wheeled furniture, use wide, non-marking, soft double swivel castors compliant with DIN EN 12529. Floor protection mats should be used in areas that are subject to heavy wear (desks etc.).

3. To keep your floor looking great, clean it at least twice a week using a broom, dust mop or vacuum cleaner, more often if it gets a lot of use. Do not use household anti-dust cleaners as they may make

the floor slippery or damage the surface. Just give the floor a clean with a dust mop or broom as often as you need to.

4. Protect your floor from damage by pets with uncut claws. They may scratch the surface badly. The same applies to high-heeled shoes that do not have appropriate heel protection or objects and furniture with sharp edges.

5. Protect your floor from prolonged exposure to sunlight. Use curtains or blinds during the period of strongest sunlight to prevent direct sunlight from reaching the designer flooring. Most floor coverings are sensitive to constant, strong sunlight. To avoid an uneven appearance, move any existing strips of carpet to a different location every so often. High temperatures (> 60 °C for SPC flooring, > 32 °C for vinyl/susify flooring) will damage vinyl designer floor coverings. The use of air conditioning should be considered in empty buildings. If indoor temperatures are below 10 °C or above 35 °C for an extended period, this will damage your design floor when combined with strong, direct sunlight and may lead to fading of the pattern, bowls, corrugations or loosening of the joints.

6. DO NOT use a steam cleaner on the floor coverings, as this may cause permanent damage to the flooring and invalidate your warranty claims.

26 Cleaning and care – General information on cleaning

TIP

To avoid dirt from driveways or parking areas, always use NON-stick or rubberised floor mats in entrance areas. You should use special accessories for hard surfaces when vacuuming your floor.

REGULAR CARE

1. Only use a high-quality liquid cleaner that is suitable for PU-coated floors for care and cleaning. Ensure correct use in terms of applicable regulations as indicated on the product label. Hand wiping may be required to remove stains from tricky areas. Sweep or vacuum the designer flooring before each cleaning so that any loose dirt or particles are removed. We advise against using all-purpose cleaners, as they often contain abrasive powder or oily soaps.

2. Normal household dirt can be cleaned with a designer flooring cleaner as described in the product's instructions. Stubborn stains and spilt liquids may need to be cleaned by hand. Sweep or vacuum your designer flooring before cleaning to remove loose dirt and particles. For best results, you should avoid using combined cleaning and care products.

3. Food stains should be removed as quickly as possible and cleaned using a high-quality cleaner suitable for designer flooring.

4. Do not use cleaning cloths or cleaning utensils that contain micro-fibres. These are abrasive and frequent use of these will make the PU surface rougher.

5. If the scratches are caused by normal household use and are thin but not too deep, all you need to do is clean the affected surfaces, wash them with water and treat them after drying with a cleaning and sealing agent suitable for PU-coated surfaces. Then the surface will shine like new again.

6. Damaged panels may need to be replaced if your floor has unusually deep scratches.

7. Only mats made of vinyl (PVC) or cotton should be used as floor mats / floor protection mats for e.g. dirt traps, office chair castors etc. Rubbercoated mats are unsuitable and may cause a chemical reaction, discolouration and detachment of the protective layer.

8. DO NOT USE WAX POLISH ON YOUR DESIGNER FLOORING! The surface is very dense and nonporous; this means that the wax cannot penetrate, but accumulates on the surface and leads to yellowing and the accumulation of dirt. The impermeability and robustness of the PU surface of the designer flooring provides the required protection against wear and dirt.

9. There is no need to panic If your flooring has been exposed to excessive amounts of water due to flooding. Vinyl is waterproof! Just use a water vacuum cleaner or other device to remove the water as quickly as possible and ventilate the room. You should place a dehumidifier in the room immediately to get the humidity back to normal levels. Do not dry the room beyond the normal level of humidity that was present beforehand.

27 Cleaning and care – General information on cleaning

General information on cleaning of ecological floors

Congratulations! You have finished laying your new flooring. Your new flexible floor covering has been manufactured to the highest quality standards and will give you long-lasting enjoyment. Follow the recommendations in these instructions to keep your floor looking like new and maintain the factory finish.

PREVENTATIVE CARE

1. Use protective mats WITHOUT A LAYER OF RUBBER by doors that lead outside. This stops sand and gravel getting onto your floor. With all floor coverings, coarse-grained sand is public enemy number one.

2. Attach suitable furniture glides (preferably made of felt) to all pieces of furniture that you place on an elastic floor covering. Furniture glides allow chairs to be moved across the floor easily without any scratches or scuffs. Clean the furniture glides regularly to remove dirt that may have accumulated underneath. For swivel chairs and other pieces of furniture on castors, please use 5 cm wide, nonmarking castor feet (type W). Do not use rubber rollers. For office swivel chairs or other wheeled furniture, use wide, non-marking, soft double swivel castors compliant with DIN EN 12529. Floor protection mats should be used in areas that are subject to heavy wear (desks etc.).

3. To keep your floor looking great, clean it at least twice a week using a broom, dust mop or vacuum cleaner, more often if it gets a lot of use. Do not use household anti-dust cleaners as they may make

the floor slippery or damage the surface. Just give the floor a clean with a dust mop or broom as often as you need to.

4. Protect your floor from damage by pets with uncut claws. They may scratch the surface badly. The same applies to high-heeled shoes that do not have appropriate heel protection or objects and furniture with sharp edges.

TIP

To avoid dirt from driveways or parking areas, always use NON-stick or rubberised floor mats in entrance areas. You should use special accessories for hard surfaces when vacuuming your floor.

REGULAR CARE

susify floor coverings are easy to clean: vacuuming, damp mopping or sweeping with a broom is sufficient. Please do not wet vacuum. Suitable cleaning agents: You can add a little universal cleaner to the mopping water. Please do not use alkaline cleaning agents.

28 Cleaning and care – General information on cleaning

Basic cleaner

PRODUCT DESCRIPTION

b!design basic cleaner is the basic care for your b!design vinyl floor. For easy cleaning of small and large surfaces - so your floor will be clean again with ease.

APPLICATION

Processing (larger areas):

Dilute b!design Basic Cleaner Concentrate 1:10 with water (e.g. 0.5 L to 5 L water) and spread evenly over the floor with an articulated mop or wipe (do not leave puddles). Also suitable for cleaning machines.

Processing (smaller areas):

Apply b!design Basic Cleaner Concentrate diluted directly and spread with wrung-out damp cloth. Allow to react for 5 - 20 minutes. During this time, re-treat dried areas. Thoroughly remove loosened dirt with an articulated wiper or damp cloth. Wipe clean 2 - 3 times with clear water. Wipe dry. After complete drying, treat with b!design refresher.

STORAGE

Store b!design Basic Cleaner in the closed original. Store in a cool, dry place, protected from frost. Store under lock and key and out of reach of children.

TECHNICAL DATA

Ingredients AQUA; Tetradecanol, ethoxylated <2.5 EO, sulphates, sodium salts; sodium, 4-undecan3-ylbenzenesulfonate; CETEARYL ALCOHOL; PHENOXYETHANOL; 4-isopropenyl-1-methylcyclohexene

29
detergents
Cleaning and care – b!design

Refresher

PRODUCT DESCRIPTION

b!design refresher, the natural-based vinyl cleaning and care product. Initial care with b!design refresher is also recommended for freshly laid, industrially finished floors. Also suitable for oil and wax treated wooden surfaces. Protects the surface, regenerates, refreshes. Water and dirt repellent.

APPLICATION

The floor covering must be cleaned carefully before use so that it is free of dirt and grease afterwards. Carefully sand damaged areas with the gray sanding fleece, so that any excess scratches are evened out. Remove fine sanding dust with a slightly damp cloth. Shake the spray can vigorously for approx. 20 seconds before use. Spray on in an inconspicuous place as a test to check the color and paint compatibility. Spray b!design refresher onto the surface to be treated at a distance of approx. 30 - 40 cm in the form of a mist. To achieve an optimum result 2 to 3 coats should be applied. Between the individual applications, allow the paint film to flash off for approx. 5 - 10 minutes between the individual applications. In the case of partial repairs optical differences to the remaining surface cannot be ruled out (e.g. differences in gloss level). This can only be eliminated by full-surface renovation (e.g. with PU sealer).

STORAGE

Store the b!design refresher in the closed original. Store in a cool, dry place, protected from frost. Store under lock and key and out of reach of children.

TECHNICAL DATA

Ingredients

AQUA; STEARYL BEESWAX; Tetradecanol, ethoxylated <2.5 EO, sulphates, sodium salts; sodium;4-undecan-3-ylbenzenesulfonate; 1,2-Benzisothiazol-3(2H)-on; Gemisch aus 5-Chlor-2-methyl- 2Hisothiazol-3-on [EG Nr.247-500-7] und 2-Methyl2Hisothiazol3-on [EG Nr. 220-239-6] (3:1)

30 Cleaning and care – b!design detergents

Wipe care

PRODUCT DESCRIPTION

b!design Wiping Care Concentrate is a concentrated wiping water additive with washing-active substances and and natural care additives. For all vinyl surfaces as well as for wood and cork floors with waxed or oiled surfaces and all other wipeable floors, such as PVC, linoleum, ceramics, tiles... Cleans gently and thoroughly and streak-free. Freshens up the surface and makes it dirt-repellent. Low foamingtherefore also suitable for cleaning machines.

APPLICATION

Simply add to the wiping water - 2 closing caps are sufficient for approx. 5 liters of water. Wring out the cloth and wipe with a damp cloth. Wipe dry if necessary.

Note: For the removal of particularly strong stains, as well as for occasional refreshing and intensive care of the floor, we recommend b!design refresher.

STORAGE

Store b!design Wiping Care in the closed original Store in a cool, dry place, protected from frost. Store under lock and key and out of reach of children.

TECHNICAL DATA

Ingredients

AQUA; sodium;4-undecan-3-ylbenzenesulfonate; Tetradecanol, ethoxylated <2.5 EO, sulphates, sodium salts; Alcohol C13, branched, ethoxylated; N,N-bis(2-hydroxyethyl) dodecanamide

31 Cleaning and care
b!design detergents

Warranty conditions

The flooring has a 25-year warranty when used in private homes. And a 5-year full commercial warranty.

1. AREA OF VALIDITY

Provided that the flooring has been maintained as specified in the user manual and used within the specified usage class and installed in accordance with the installation instructions, the warranty covers the following areas only:

• Manufacturing faults

• Delamination

• Strong, unusual colour deviations and fadingprovided that the panels have not been exposed to direct sunlight.

2. THE FOLLOWING ARE EXCLUDED FROM THE WARRANTY:

• Normal wear and tear, intentional or wilful damage: Damage due to improper installation or maintenance, chemical decomposition due to unsuitable cleaning agents, alkaline base layers or defects due to hydrostatic pressure, burns, cracks, dents, stains or loss of gloss due to normal ageing or external influences.

• Visual and textural variations that can be detected before or at the latest during

installation. Laying the flooring or applying adhesive is assumed to mean that this condition has been accepted.

• Labour or labour costs for the removal of the damaged flooring and installation of the replacement flooring.

• Consequential damage in the event of restrictions of use, delayed letting date, etc., associated with the removal or re-location of the affected material. Any further compensation for incidental or consequential damages is explicitly excluded.

If consequential damages cannot be excluded due to local legal provisions, the restrictions listed under point 2 may only be partially applicable.

Specific rights are conferred by this warranty, no further claims or rights may be derived therefrom.

This warranty coverage can only be claimed by notifying the distributor/dealer immediately. The notification must be accompanied by a copy of the original invoice and a fully completed claim report with pictures, the warranty claim may only be authorised by the distributor/dealer.

32
Warranty conditions
BAUHAUS E-Business GmbH & Co. KG Gutenbergstraße 21 68167 Mannheim Deutschland T +49 800 3905 000 service@bauhaus.info www.bdesign-floors.com © Bauhaus 01.04.2024

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.