ElectricalSystem–5000 Parameters
Parameter#16to19configurableoptionalfunctions
Parameter no. #16, #17, #18 & #19 can be adjusted to activate up to a maximum of 4 pre-programmed functions and configure these to suit optional equipment or customisation of the truck. See “Table 2:List of configurable optional functions” on page 39. These are thus called the configurable optional functions.
•Each parameter can be programmed to cover a specific optional function.
•Each optional function can have up to 4 independent variables associated with it.
•Each independent variable has a value you can change to configure the function.
Parameter no. (range 16-19)
Independent variable: #0 is the option designation
Independent variable value (range 0-63) 0= no option has been activated for this parameter
1 to 63 = Pre-programmed option number. See separate table.)
Settingtheoptionalfunction
Independent variable: #1, #2, #3 & #4 contain the optional function valu Independent variable value (the range depends on the function referred The value depends on the option and independent variable selected. See separate table
16-1-1
Configuringtheoptionalfunction
Fig. 1Summary – option parameter
Changingconfigurableoptionalfunctions
In order to activate a configurable optional function, it must first be assigned a parameter from #16 to #19. This is done by changing independent variable #0 to the pre-programmed option number. Once this has been done, the independent variable for the option must be configured. This is done by changing the values for independent variables #1, #2, #3 and #4.
•Ensure the truck is in parameter mode.
The parameter symbol is lit.