1 minute read

Electrical systems – 5000

# 21 - Battery size

Matches the discharge indication to the characteristics of the battery fitted.

To adjust the disconnection point of the battery discharge indicator, measure according to:

•Acid concentration when fully charged battery. To check quality of battery. Shall be between 1,27-1,29.

•When you get lift cut-out (80% discharged of battery capacity) you shall have close to 1,14 not less.

The acid concentration can vary depending on battery brand.

Table 18: Battery size parameter

* TBA = To be announced WARNING!

Ensure you have set the parameter correctly. The battery may otherwise be irreparably damaged.