1 minute read
Electrical systems – 5000
# 21 - Battery size
Matches the discharge indication to the characteristics of the battery fitted.
To adjust the disconnection point of the battery discharge indicator, measure according to:
•Acid concentration when fully charged battery. To check quality of battery. Shall be between 1,27-1,29.
•When you get lift cut-out (80% discharged of battery capacity) you shall have close to 1,14 not less.
The acid concentration can vary depending on battery brand.
Table 18: Battery size parameter
* TBA = To be announced WARNING!
Ensure you have set the parameter correctly. The battery may otherwise be irreparably damaged.