Electrical systems – 5000

Parameters & adjustments

10.5.3 Adjusting operator parameterswithout the CAN service key NOTE!

Operator parameters can only be set without a CAN key if parameter #39 is set to value “1”, “3”, ”5”, “7”, “9” or “11”. See # 39 - Log-in method & operator parameter access on page 47

To change the value of a particular operator parameter carry out the following:

•Switch on the truck and log in with the appropriate PIN-code. This is important if the truck has more than one set of Operator parameters active . Any changes made will only be in effect when that particular “operator” is logged in.

•Select the required parameter.

•Press horn button S18.

Parameter symbol flashes.

•Set parameter value by repeatedly operating speed control L1 up or down

•Press horn button S18 once to confirm the new setting.

Parameters symbol lights. (stops flashing).

•Switch off the truck by pressing on the keypad. You have now completed a parameter change and the next time you start the truck the new parameter setting will be valid.

For detailed descriptions and effects of these parameters, see the section Description of operator parameters on page 37

10.5.4 Displaying & changing parametersCAN service key connected

•Ensure the battery is connected.

•Connect a suitable CAN-service key to X41.

•Ensure the truck is switched off. Press on the keypad.

•Press and hold horn button S18 for at least 1 second and then press on the keypad.