115JPT5-212VPSupplies working voltage to the 120/150 in. switch (S29). If not present, check voltage at STM JPT9-6 and see if IL1 is lit.
116JPT5-1HEIGHT 120/150 in. SW (S29)
Supplies B– to circui try on the STM when the switch is closed. When the switch is open, the lift truck has limited travel speed.
117JPT5-3DGNDB– for S29, su pplied through the STM via B– cable at the TPA.
118JPT5-512VPSupplies work ing voltage to the180 in. switch (S25). If not present, check voltage at STM JPT9-6 and see if IL1 is lit.
119JPT5-4HEIGHT 180 in. SW (S25) Supplies B– to circui try on the STM when the switch is closed. When the switch is open the lift truck has limited travel speed.
120JPT5-6DGNDB– for S25, su pplied through the STM via B– cable at the TPA.
121JPT5-812VPSupplies working voltage to the Lift-Limit Switch (S24). If not present, check voltage at STM JPT9-6 and see if IL1 is lit.
122JPT5-16LIFT LIMIT SW (S24) Supplies B– to circui try on the STM when the switch is closed. When the switch is open the lift truck has no lift unless the bypass switch (S51) is closed.
123JPT5-7DGNDB– for S24, su pplied through the STM via B– cable at the TPA.
124JPT7-212VPSupplies working voltage to the optional switch. If not present, check voltage at STM JPT9-6 and see if IL1 is lit.
125JPT7-1SPARE IN 3Supplies B– to circuitry on the STM when the switch is closed. When the switch is open, the lift truck disables the appropriate function.
126JPT7-3DGNDB– for the optional switch, supplied through the STM via B– cable at the TPA.