1 minute read

Model 5200 High-Level Orderpicker

Code 7,7

Code 7,7

How

Corrective Actions and Checks

Step on and off the deadman pedal to clear. If the code does not clear, follow the procedure below.

NOTE: Check for shorts to frame. Check for shorts or openings in wiring between the Carriage Manager, Steer/Tractor Manage, and Guidance Manager. Check the power supply voltages on the STM. If they are not steady or dip during operation, test all components and wiring to the components that use 12V or 5V for shorts. Replace the STM.

Publication Number: 1043922B, Revised: 2 Sept 20156-79

Model 5200 High-Level Orderpicker

Code 7,7 6-80Publication Number: 1043922B, Revised: 2 Sept 2015