Pinout Matrix Single Traction Motor Trucks >S/N 10676
42JCM-8 +V Voltage from the HCB to the Left (EV5) and Right (EV6) Sideshift Solenoids. If not present, check the HCB, wiring, and connections. Note: This voltage is common to both solenoids. If this voltage is lost, neither solenoid will work.
43JCM-9 thru 11NOT USED
44JCM-124th FUNCTIONVoltage from the HCB to turn on the 4th Function Solenoid (EV7). If not present, check the HCB, wiring, and connections.
45JCM-13+V Voltage from the HCB to the 4th Function (EV7 and EV8) Solenoids. If not present, check the HCB, wiring, and connections. Note: This voltage is common to both solenoids. If this voltage is lost, neither solenoid will work.
46JCM-144th FUNCTIONVoltage from the HCB to turn on the 4th Function Solenoid (EV8). If not present, check the HCB, wiring, and connections.
47JCM-15R SIDESHIFTVoltage from the HCB to turn on the Right Sideshift Solenoid (EV6). If not present, check the HCB, wiring, and connections.
48JCM-16 thru 18NOT USED
49JCM-19DRAIN Voltage from the HCB to turn on the Drain Solenoid (EVP). If not present, check the HCB, wiring, and connections.
Approx. 18V wrt
B+ (approx. 22ohms across coil)
HCBEV5, EV6
50JCM-20+V Voltage from the HCB to the Drain Solenoid (EVP). If not present, check the HCB, wiring, and connections.
51JCM-21 and 22NOT USED
52JCM-23GND B– supply to optional HCB. This B–is shared by many components prior to and after the VM. If not present, follow back towards B–until loss can be determined.
Approx. 18V wrt B+ (approx. 22ohms across coil)
Approx. 18V wrt B+ (approx. 22ohms across coil)
Approx. 2-13V wrt B+ when requesting lift and/or any aux function. (approx. 18 ohms across coil)
HCBEV7
HCBEV7, EV8
HCBEV8
HCBEV6
HCBEVP
Battery voltage wrt BT1+ B– at J1–HCB
53JCP-1 CAN L Communication between the PPA and the TPA (JCT-2). N/A TPA, PPATPA, PPA