1 minute read
Model 4700 Maintenance Manual
Section 8.Theory of Operation
Single Traction Motor Trucks >S/N 10676 Pinout Matrix
272J117-1 DRAIN Voltage from the HCB (JCM-19) to turn on the Drain Solenoid (EVP). If not present, check the HCB, wiring, and connections.
Approx. 2.5V static; Approx. 2 to 13V wrt J117-2 when lifting or performing an aux function (approx. 18ohms across coil)
273J117-2 +V
Voltage from the HCB (JCM-20) to turn on the Drain Solenoid (EVP). If not present, check the HCB, fuse F21, wiring, and connections.
Approx. B+ when lifting or performing an aux function
274J119-1 +V
Voltage is supplied to the optional Lift Limit Bypass solenoid when SW16 is normally closed. When SW16 opens, the Lift-Limit Bypass button PB9 must be depressed to allow lift. If not present, check wiring, fuse, switches, and connections.
+24V
275J119-2 B–
B– supply from Battery. This B– is used by the optional Lift-Limit Bypass Valve (EV12). If not present, follow back towards B– until loss can be determined.
276J137-1 CAN L Communication line between Operator Display and VM (J34-21).
277J137-2 CAN HCommunication line between Operator Display and VM (J34-33).
278J137-3 GND B– supply from Battery. This B– is used by the Operator Display. If not present, follow back towards B–until loss can be determined.
279J137-4 NOT USED
280J137-5 +V +24V supply to Operator Display from the VM (J34-12). If not present, check fuse F14, wiring, and connections.
281J137-6 GND B– supply from Battery to the Operator Display. This connection supplies B– to the CAN-Bus Interface by use of a jumper. If not present, follow back towards B–until loss can be determined.
Publication 1160093, Issued: 20 May 2013
Section 8.Theory of Operation
Pinout
Model 4700 Maintenance Manual
Matrix Single Traction Motor Trucks >S/N 10676
282J138-1 GND B– supply from Battery. This B– is used by the optional Fingertip Armrest Board. If not present, follow back towards B– until loss can be determined.
Battery voltage wrt BT1+ BT1Fingertip Armrest Board
N/A
Armrest Board
284J138-3 GND B– supply from Battery. This B– is used by the optional Fingertip Armrest Board. If not present, follow back towards B– until loss can be determined.
Battery voltage wrt BT1+ BT1Fingertip Armrest Board
N/A PPAFingertip
Armrest Board
+24V VMArmrest
Board
B+ F3HCB 289J140-2 B+ B+
290J140-3
B– supply from Battery. This B– is used by the optional HCB. If not present, follow back towards B–until loss can be determined.
291J140-4 CAN L Communication line between HCB and VM (J40-8).
N/A VMHCB
N/A VMHCB
295J141-1
GND
296J141-2 NOT USED
Optional voltage from Armrest Board to PB13. input to Armrest Board from PB13. closed; 5V open
Armrest Board Armrest
Publication 1160093, Issued: 20 May 2013