All Dual Traction Motor Trucks and Single Traction Motor Trucks <S/N10677Pinout Matrix
150J15-2 GND
Single Traction Motor TruckGround to the Traction Motor (TM) encoder (EN1) from the TPA (JT6-2). If not present, check the TPA, wiring, and connections.
Battery voltage wrt BT1+ TPAEN1
151J15-3 RTM ENCODER CHANNEL B
Dual Traction Motor TruckChannel B from the Right Traction Motor (RTM) encoder (EN1) to the TPA (JCT-14). If not present, check voltage to the encoder, wiring, and connections.
Approx. 5V running; 0V or 10V static
EN1TPA
152J15-3 TM ENCODER CHANNEL B
Single Traction Motor TruckChannel B from the Traction Motor (TM) encoder (EN1) to the TPA (JT6-5). If not present, check voltage to the encoder, wiring, and connections.
Approx. 5V running; 0V or 10V static
EN1TPA
153J15-4 RTM ENCODER CHANNEL A
Dual Traction Motor TruckChannel A from the Right Traction Motor (RTM) encoder (EN1) to the TPA (JCT-13). If not present, check voltage to the encoder, wiring, and connections.
Approx. 5V running; 0V or 10V static
154J15-4 TM ENCODER CHANNEL A
Single Traction Motor TruckChannel A from the Traction Motor (TM) encoder (EN1) to the TPA (JT6-3). If not present, check voltage to the encoder, wiring, and connections.
Approx. 5V running; 0V or 10V static
155J15-5 GND
Ground from the VM (J34-6) to the TM temperature switch (TS1). If not present, check the VM, wiring, and connections.
Battery voltage wrt BT1+
156J15-6 RTM TEMP SW (TS1)
Dual Traction Motor TruckInput to the VM (J34-26) from the RTM temperature switch (TS1). Input will be low under normal operating conditions. If overtemp condition exists [>266°F (130°C)], input will be high. Allow to cool. If still open (high), check the switch, wiring, and connections.
Approx. 0V closed; 5V open
157J15-6 TM TEMP SW (TS1)
Single Traction Motor TruckInput to the VM (J34-27) from the TM temperature switch (TS1). Input will be low under normal operating conditions. If overtemp condition exists [>266°F (130°C)], input will be high. Allow to cool. If still open (high), check the switch, wiring, and connections.
Approx. 0V closed; 5V open
Publication 1160093, Issued: 20 May 2013 8-25
Section 8.Theory of Operation
Model 4700 Maintenance Manual
Pinout MatrixAll Dual Traction Motor Trucks and Single Traction Motor Trucks <S/N10677
158J15-7 thru 9NOT USED
159J16-1+12V+12V to the Left Traction Motor (LTM) encoder (EN2) from the TPA (JCT-11). If not present, check the TPA, wiring, and connections.
160J16-2 GND Ground to the Left Traction Motor (LTM) encoder (EN2) from the TPA (JCT-12). If not present, check the TPA, wiring, and connections.
161J16-3 LTM ENCODER CHANNEL B Channel B from the Left Traction Motor (LTM) encoder (EN2) to the TPA (JCT-23). If not present, check voltage to the encoder, wiring, and connections.
162J16-4 LTM ENCODER CHANNEL A Channel A from the Left Traction Motor (LTM) encoder (EN2) to the TPA (JCT-22). If not present, check voltage to the encoder, wiring, and connections.
163J16-5 GND Ground from the VM (J34-6) to the LTM temperature switch (TS2). If not present, check the VM, wiring, and connections.
164J16-6 LTM TEMP SW (TS2)
Input to the VM (J34-27) from the LTM temperature switch (TS2). Input will be low under normal operating conditions. If overtemp condition exists [>266°F (130°C)], input will be high. Allow to cool. If still open (high), check the switch, wiring, and connections.
Battery voltage wrt BT1+ TPAEN2
Approx. 5V running; 0V or 10V static
Approx. 5V running; 0V or 10V static
EN2TPA
EN2TPA
Battery voltage wrt BT1+ VMTS2
Approx. 0V closed; 5V open TS2VM
165J16-7 thru 9NOT USED
166J20-1 SEAT Input from the Seat switch (SW2). If not present, check the seat switch, jumper at J22-A3 and J22-A4, wiring, and connections.
167J20-2 NOT USED
168J20-3 +V OUTB+ from TPA to Seat switch (SW2). If not present, check the seat switch, battery interlock switch (SW30), jumper at J22-A3 and J22-A4, wiring, and connections.
169J23-1 +V OUT Dual Traction Motor TruckVoltage from TPA to Battery Interlock switch (SW30). If not present, check TPA, switch, wiring, and connections.
SW2TPA
TPASW30, SW2
Publication 1160093, Issued: 20 May 2013