1 minute read

Section 6.Messages and Codes

Fault Codes 6-22

Model 4700 Maintenance Manual

Refer to the “Pinout Matrix” located in Theory of Operation section for all voltage and resistance values and component interconnection.

Code Description

8B Code 8B: TPA Fault

The TPA informed the VM that a fault is present.

8C Code 8C: TPA Communication Error

The VM did not receive communication from the TPA.

8D Code 8D: Lift Limit Lift-Limit switch (SW31) is open.

Notes/Corrective Action

Check voltage to the TPA. Check for TPA codes and troubleshoot per them. If none are present, replace the TPA.

If code clears by cycling Key switch, the adjustable parameters have been reset to default values and require resetting to customer’s requirements via FlashWare. Check power to TPA. Check the power cables to the traction motors. Check both traction motor encoders, temperature sensors, and connections. Check communication wires between the TPA and VM for continuity and shorts to frame. If code does not clear by cycling key, replace the TPA.

Check for correct configuration via FlashWare. (This code is normal and will occur when beyond limits for option.)

Check Lift-Limit/Bypass switch (SW31) and wiring. If OK, replace PPA.

8E Code 8E: Bottler’s Tilt Limit

Bottler’s Tilt limit switch (SW30) is open.

8F Code 8F: Requesting Travel In Both Directions

Forward and Reverse switches (directional lever on column) are closed at the same time.

91 Code 91: Configuration Error

The VM has detected a configuration error due to lack of information from the Hydraulic Control Board or Armrest Board during SelfTest.

Check for correct configuration via FlashWare. (This code is normal and will occur when beyond limits for option.)

Check Bottler’s Tilt limit switch (SW30) and wiring. If OK, replace VM.

Troubleshoot switches and wiring. If OK, replace TPA.

Check power to the Hydraulic Control Board (HCB). Check communication wires between PPA, HCB, and Armrest Board for continuity and shorts to frame. Make sure COMBI jumpers are correctly installed at Armrest Board. Check software versions via FlashWare. If the HCB and/or Armrest Board are not displayed on the Truck Setup screen, “flash” the truck. Replace HCB or Armrest Board.

Publication 1160093, Issued: 20 May 2013