1 minute read
844/642 TelehandlerFRAME LEVELING CYLINDER
Frame Leveling Cylinder Removal
NOTE: See Section 605 of this Service Manual for the repair of this cylinder.
Mandatory Safety Shutdown Procedure
BEFORE cleaning, lubricating, or servicing this equipment:
1.Bring the machine to full stop on a level surface. (If parking on a slope or hillside cannot be avoided, park across the slope and block the tires.)
2.Fully retract the boom and lower the attachment to the ground.
3.Place controls in NEUTRAL and set park brake.
4.Idle Engine for gradual cooling.
5.Turn the starter key switch to OFF position and remove key (take key with you for security reasons).
ONLY when you have taken these precautions can you be sure it is safe to proceed. Failure to follow the above procedure could lead to death or serious personal injury.
Relieving Hydraulic Pressure
1.Fully retract and lower the telescoping boom to the ground.
2.Turn the key switch to the OFF position to shut down the engine. (See above Mandatory Safety Shutdown Procedure.)
3.Move the frame leveling joystick in all directions to relieve hydraulic pressure.

Template Name: OML_2_col
907872
Template Date: 1994_04_22 Alt= to hide template information Alt+ to display template information