REMOVING THE BOOSTER PUMP.............................................................................................................................E2

Hydraulic source60 l/min

Replacing the RH cover

Important: Systematically replace all the seals.

–Clean the housing and cover gasket faces. –Check the presence of the two centring pins on the cover. –Coat the cover seal face with Loctite(510).

Note: Be careful not to obstruct the ducts.

–Refit the cover (1), the filter holder (4) and tighten the screws (3) to 12 daNm. –Refit the solenoid valves. –Tighten the screws(2) to a torque of 2,5daN.m. –Refit the strainer (5). –Connect the hydraulic pipes and hoses. –Check the operation of the electrical components. –If a hydraulic component has been dismantled or replaced, test the hydraulic circuit. Check the seals on the gasket face and the hydraulic connections.

3

394msm1g

1

5 2

6 4

Fig.5