1 minute read

15.7 Battery connector

15.6.2 Battery lock sensor functionality check

1. Connect the supply voltage between the brown (+) and blue (-) wires. 2. Measure the supply voltage between the wires.

The value should be +24Vdc.

3. Measure between the blue (-) and black (output) wires on the voltage area.

When a supply is connected and there are no metallic objects within the sensing range, the value is approximately 0V.

When a metallic object is moved within the sensing range, the value is the same as the supply voltage, i.e. +24Vdc. 4. If the values do not match the above, replace the sensor.

This option is a replacement for a defective battery connector.

NOTE: Make sure that you set the mechanical voltage selector to the correct battery voltage (24 V)! Also note the polarity of the battery cables.

Copyright© 2013 by MCFE. All rights reserved. Revision: B Document ID: 615025 189 (210)