2 minute read
1-2-5. Rotary switch on the EPS controller
from Caterpillar EP13TCB(J) EP15TCB(J) EP16 18 20TCB(J) EP16 18 20TBCB(J) Controller Service Manual - PDF
The rotary switch (RS) on the EPS controller enables you to select the option settings and adjustment screens shown in the table below.
<Rotary Switch (RS) setting>
RS Functions Remarks
0
MONITORING OK Displayed when key switch is ON. Normal monitor screen Battery discharge indicator, Travel speed, Hour meter, Error, Clock, Calendar Hour meter check Shows hour meter counter (Total, Travel, and Hydraulic) Date / time setting screen Set date and time Slow speed mode setting Set maximum speed in slow speed mode (2, 3, 4, 5, 6, 7, 8, 10, 12 km/h) Travel mode setting Select travel mode (Economy, Normal, Power) Hour meter, odometer, load weight setting Select meter indication (Hour meter, odometer, load weight) Display mode setting Set brightness of the display screen (0-7: back light adjustment) Neutral (accelerator OFF) regeneration mode setting Select neutral regeneration mode (Non, Low, Mid, High) Pitching control Switch pitching control ON / OFF 1 Monitor symbol setting Set monitor symbol (STEER, BATT, OIL, LOAD, BRAKE) 2 Forklift model setting Set the truck model on the travel/hydraulic board
3 Plugging strength setting Set plugging (switch back) brake strength (0-32) Brake strength setting Set regenerative brake strength (0-32) Pitching control volume setting Set pitching control volume (20, 30, 40, 45)
Lift speed limitation 1 setting: Low travel speed Set lift speed limit (0-32): Travel speed 0 - 5 km/h
Lift speed limitation 2 setting: Middle travel speed Set lift speed limit (0-32): Travel speed 5 - 10 km/h
4 Lift speed limitation 3 setting: High travel speed
Set lift speed limit (0-32): Travel speed 10 km/h over Lift speed 1 setting Set lift speed 1 (0 - 32 :1st microswitch) Lift speed 2 setting Set lift speed 2 (0 - 32 :2nd microswich) Tilt speed setting Set tilt speed (0 - 32) Attachment 1 speed Set attachment 1 speed (0 - 32) Attachment 2 speed Set attachment 2 speed (0 - 32) Attachment 3 speed Set attachment 3 speed (0 - 32) Hydraulic handling Set hydraulic handling (1 - 8 : Over drive , Reaction adjustment ) 5 Language selecting Select language (Six languages) 6 Option setting Set optional functions
RS Functions Remarks
7 Status check Check voltage, motor current, transistor temperature
8 RAM and I/O memory data check
9 Error history memory 1 Check error history (latest 10 cases) Error history memory 2 Check error history (all past cases)
A Battery voltage setting Voltage settings for capacity standards
Overload warning setting Set overload weight value
B Reduce turning speed 0 - 16 Electricity consumption/ reduced CO2 setting Electricity rate: 0.0 - 50.0 [Japanese Yen/kWh] Reduced CO2 amount: 0.0 - 1.00 [kg/kWh]
C AOS setting 1 Set lift end / tilt end and other settings
D AOS setting 2 Check lever switch
E Memory initialize Initialize error history memories.
F Normal screen 2 No errors are displayed on the screen.
* See "1-2-6. Adjustment Standards List for EP-TCB series" on the next page for parameters.
NOTE For brake strength and hydraulic speed, "0" is weakest/slowest, "32" is strongest/fastest.