6.2 Maintenance activities
from Cat Electric Rope Shovel 295HD/ HR Drive Converter Cabinet Bucyrus Shovel Operation & Maintenance Ma
Code Interval code Operating hours Time period Activity
R2 Overhaul 1 24000 h 6 years • Replace the coolant • Coolant pump: Replace and overhaul in an authorized workshop • Clean the DCC - inner spaces • Visibly check the power connections / glands for abnormal color
• Check the main and auxiliary contacts of the contactors as well as the busbar connections in the DCC
4 x I4 32000 h 8 years • Cooling system: Check all of the hose connections to ensure that they are not leaking and are not porous, if required, replace hoses • Check all of the painted surfaces of the DCC for damage, repair the paint finish R3 Overhaul 2 48000 h 12 years • Replace the DCU fan assembly
Check – VI
No. Component Maintenance work
1 Entire DCC Visually check the DCC for dust, dirt, any physical damages Nil
Cross-reference
No. Component
1 Main cooler Clean
Interval 1 - EI
Maintenance work Cross-reference
Refer to Chapter 6.3
Interval 2 – I2
No. Component
1 Insulators
Maintenance work
Check and clean insulators of PTB2 terminals & motor connection terminals on DCC for dirt accumulation
2 Air conditioner Clean the heat sink fins of air conditioner from outer side of DCC
Cross-reference
Nil
Refer to Chapter 6.17
Interval 3 – I3
No. Component Maintenance work
1 Cooling system Check the level of the liquid and if required top up Refer to Chapter 6.4
Siemens Ltd. A5E01511750J/ 4M-2601-1645240 AC Shovel 295HD/ HR DCC Operation & Maintenance Manual
Cross-reference
2 Cooling system Cooling medium specimen, analysis Refer to Chapter 6.5 3 Cooling system Check that the cooling medium connection seals for leaks Refer to Chapter 6.6
4 Coolant pump Check for vibration, noise in operation, damage and leaks
5 Door gaskets Apply grease (jelly) on door gaskets to prevent adhesion/ sticking of gasket to cabinet 6 Air conditioner Check air conditioner fans Refer to the Operating Instructions of the coolant pump Nil
Nil
Interval 4 – I4
No. Component Maintenance work Cross-reference
1 DC link capacitor Check the capacitance value Refer to Chapter 6.10
2 Blower
3 DCU Check the Blower for heat exchanger Refer to Chapter 6.11 Check DCU fans SIBAS equipment manual
2 x I4 - the same activities as I4 - and in addition
No. Component Maintenance work
1 Main blower fan motor Bearings of motor: Replace in qualified workshop
2 Internal cooler Bearings of motor: Replace and overhaul in qualified workshop
Cross-reference
Refer to Chapter 6.11 and the Operating Instructions of the central fan
Refer to Chapter 6.9 and the instructions of the indoor coolers
3 Door gaskets Replace the gaskets on maintenance cover Refer to Chapter 6.16
R2 – overhaul 1
No. Component Maintenance work
1 Cooling system Replace the cooling liquid 2 Cooling medium pump Replace the coolant pump and overhaul in an authorized workshop
3 DCC
Clean the inside space 4 Switching devices Check the main and auxiliary contacts of the contactors as well as the busbar connections in the converter
Cross-reference
Refer to Chapter 6.7 Refer to Chapter 6.8
Refer to Chapter 6.12 Refer to Chapter 6.13
Siemens Ltd. A5E01511750J/ 4M-2601-1645240 AC Shovel 295HD/ HR DCC Operation & Maintenance Manual 76