1 minute read
When Required
AS REQUIRED
Operations to be performed when the relevant indicators are activated:
1. Indicator - hydraulic oil filter clogged 2. Indicator - engine air cleaner clogged
Operation to be performed when indicator 3 on the instrument board comes ON indicating that the return oil filter is clogged. See operation no. 19. 37. FUEL FILTERS Draining the condensation
Operation to be performed when the blue indicator on the monitor panel comes ON, indicating the requirement for the draining of water from the fuel filter.
3550-M005
35. ENGINE AIR CLEANER CLOGGED Clean the cartridges
Operation to be performed when indicator 1, located on the instrument board indicates that the air cleaner is clogged. See operation no. 27.
36. OIL FILTER ON EQUIPMENT HYDRAULIC CIRCUIT RETURN Replace the filtering cartridge
WARNING Fluid under pressure. Turn the cap slowly to release the pressure before removing it. Draining condensation
D350M0063
Open the left upper panel of the engine compartment, perform the draining of the water and sediments from the fuel filter through the draining valve indicated. With engine inoperative, loosen the valve located under the filter about 4 full turns and move it downward about 2 cm. Let any water and sediment flow until clean fuel only gets-out. Push the valve upward and tighten, avoiding overtightening.
D350M0123