4.7 Emergency stop operation

4.7 Emergency stop operation

Press the emergency stop switch. When this switch is pressed, the engine stops and all of the functions are disabled. Press the emergency stop switch in the following cases:

(1) To stop the engine. (2) When personnel on board the platform stops all of the machine movements to avoid danger. (3) When the machine is uncontrollable due to malfunction.

Emergency stop switch

Engine start switch

ADVICE To resume operation, pull the emergency stop switch.

CAUTION If the boom descends gradually after pressing the emergency stop switch, this may be caused by a natural descent of the hydraulic cylinder. In this case, restart the engine with the engine start switch and operate the boom to prevent the boom and the platform from coming into contact with any obstacles. Then, lower the platform to the ground and stop using the machine. If the emergency stop operation was used as a result of malfunctions, stop using the machine and contact Aichi service shop for inspections.