1 minute read

ift AS3Line Inspection Form - AutoSh

Next Article
Opening

Opening

Line Inspection Form - AutoShift AS3

Eaton® Fuller® AutoShift™ AS3

Line Inspection OEM: Chassis S/N: Trans Model: Trans S/N: Clutch Size/Type:

Description Pre-Start Checks 1. Ignition Bus Check: Does service light turn on and tone sound? 2. Power Supply check: (manual reset type) or fuse Min. 10 amp Ignition Bus Min. 30 amp Main Power 3. Oil Fill (see lubricant section for details) 4. Power up procedure: System powers up and “N” on Gear Display DYNO/Road Test Checks 1. Verify the engine doesn't crank in any position other than neutral 2. Verify correct clutch free travel and adjustment- see OEM clutch literature 3 All forward and reverse gears obtained with engine control 4. Verify transmission temperature gauge is functional - if equipped 5. Verify gear display module works correctly 6. Verify engine retarder is functional - if equipped 7. Verify shift input device panel lights are functional 8. Verify no transmission oil leaks or residue 9. Verify the transmission diagnostic connector is accessible 10. Verify correct Shift Label 11. Verify lubricant type and brand label affixed to transmission fill plug 12. Clear Fault Codes and verify diagnostic connector functions 13. Prior to shipment of Eaton Automated Transmission Systems installed at OEM plants, the engine ECU must contain the proper configuration settings. For the proper engine configuration settings required for Eaton Automated Transmission operation refer to the “Engine Configuration Settings Installation Guide” on roadranger.com under the literature center. Comments: Yes No Corrected

Final Inspection Date: Signature: