Uncoated Expanded Polystyrene Systems (EPS)

Page 1

RENDERTEX ® SYSTEM FOR EPS

Uncoated/Unweathered

Expanded Polystyrene Systems

1. RENDER

Renderbase High Polymer Strength (HPS) Render Just add water. Trowel applied.

1 bag covers approx 4-5 m2 @ 3-4 mm thick.

Uncoated unweathered EPS requires a minimum of 2 coats of HPS render with reinforced fibre-glass mesh embedded between coats, see overleaf for more details. Note: For QLD/Nth NSW projects the equivalent Rendertex Renderbase Q can be used as an alternative.

2. PRIMER

Rendertex Renderprime Applied to achieve even suction over render and promotes inter-coat adhesion. Covers up to 150 m2/15 L

3. TEXTURE

COATINGS

Choose from our range of roll-on or trowel-on textures: Rendertex Eureka Marble Medium Covers up to 12 m2/15 L Rendertex Torquay Marble Coarse Covers up to 12 m2/15 L

Rendertex Sovereign Quartz Medium Covers up to 12 m2/15 L

Rendertex Riverina Sand Covers up to 12 m2/15 L

Rendertex Texture coatings can be tinted to an extensive variety of colours.

4.

PROTECTIVE COATINGS

Choose from: Rendershield Low Sheen Covers up to 75 m2/15 L

Rendershield Matt Covers up to 75 m2/15 L

Rendershield Clear Covers up to ~105 m2/15 L Armourguard Low Sheen Covers up to 90 m2/15 L Rendertex Texture coatings can be tinted to an extensive variety of colours.

SUBSTRATE - Uncoated Expanded Polystyrene System Eureka Marble Medium tinted to Colorbond® Paperbark®
RTX0098 V3. May, 2023.
Rendershield Low Sheen tinted to Colorbond® Paperbark®

IMPORTANT REQUIREMENTS

Uncoated EPS panels must be installed in accordance with the manufacturer’s instructions. Refer to the manufacturer’s Technical Manual.

Frame details and panel fixings must comply with relevant building codes.

• Timber framing must comply with AS1684-1992 National Timer Framing Code.

Metal framing must comply with AS3623-1993 Domestic Metal Framing. All exposed corners and bottom edges of the panels must be protected with approved trims designed for a build of 3-6 mm.

• When coating onto uncoated EPS panel where the surface is exposed to U.V (sunlight) even for a few days the panel surface MUST be thoroughly cleaned to remove any oxidised layer on top of the panel. HPS render will NOT stick to oxidised uncoated EPS. Use a stiff bristled brush and remove oxidised layer by scrubbing panels back to clean foam.

• Once application of the Rendertex system has occurred, the applicator is taken to have approved the installation and fixing of the panels.

• Ensure that the surface is clean, sound, dry and free from contaminants including oil, grease, dust, dirt, silicone, mud, salt, efflorescence, animal droppings and any loose or flaking material.

Avoid application in full sun, on hot surfaces or in hot windy conditions. Application should be carried out on a day with temperatures above 10°C and below 32°C.

Colour selection and construction design must always take into consideration the LRV of the colours to be used, the construction material and the surrounding environment. You must read the appropriate ‘Installation and Finishes Guide’ for substrate and follow the minimum LRV specification for the coating system.

• For southern states of Australia Haymes Paint Rendertex Torquay Marble Coarse, Eureka Marble Medium, Riverina Sand and Sovereign Quartz are available in a WINTER formulation. The formula varies in that it is specifically designed to flow, stiffen and cure in colder climates over winter when cooler temperatures slow the stiffening and curing process.

For further advice on requirements contact your Haymes Regional Business Manager or Haymes Service Express on 1800 033 431

PREPARATION COAT #1

Materials required:

• Renderbase HPS render, 20 kg bags.

• Alkali resistant fiberglass mesh, at least 160 gsm x 5 mm – cut pieces of mesh to size before starting the rendering.

Authorised Distributor:

Procedure:

• Prepare Renderbase HPS render as per the relevant Product Data Sheet.

• Apply a coat of HPS render at about 3-6 mm over entire surface.

While the HPS is still wet, embed fibre-glass mesh, angles and reinforcing strips. Overlapping the fibre-glass mesh by 100 mm where two sheets meet.

• The mesh MUST NOT be pushed back through the render to the surface of the panel.

Fibre-glass mesh should never overlap where two EPS panels meet. Do not render over expansion or control joints.

Screed the render coat and float off.

Allow minimum 3 to 4 hours curing time before applying second and subsequent render coats.

PREPARATION COAT #2

Apply a second coat of HPS at about 2-3 mm thick (No mesh required in this coat) to ensure your surface is level ensuring the best finish for your subsequent texture coating.

CURING TIME

Curing time allows the render to develop sufficient strength to resist mechanical damage before over coating.

In warm conditions, wetting or tempering of the freshly applied Render is recommended to ensure adequate curing.

MULTIPLE RENDER COATS

Allow minimum 3 to 4 hours curing time before applying second and subsequent render coats.

• Allow 2 to 3 days curing per coat of render before applying texture or paint coatings.

PRIMER

The render coat must be primed prior to texture coating.

• Apply one coat of Rendertex Renderprime in strict accordance to Data Sheet. Rendertex renderprime covers up to 150 m2 per 15 litre pail.

• Allow Primer to dry before commencing following coats.

TEXTURE COATING

• Apply the selected Rendertex texture and follow the appropriate Product Data Sheet. Rendertex texture coatings can be tinted to a wide range of colours to bring colour to your project.

• Application must be carried out in a brisk uniform fashion, terminating only when a whole area or section is completely coated, for example, at an expansion joint or corner.

Do not texture over expansion or control joints.

• Rendertex texture coatings should not be extended (spread) too far; otherwise durability and/or hiding power may suffer. Coverage will depend on texture profile chosen. Please refer to data sheets for spread rates.

• Allow a minimum 48 hours before commencing the paint coat.

PROTECTIVE COATING

Painting of texture with Rendertex Rendershield or Armourguard is required to fully protect against water ingress, minimize dirt build up on the surface and to extend the life of the coating system. Refer to the appropriate Product Data Sheet.

• Rendertex Rendershield Low Sheen and Matt can be tinted to a wide range of colours.

• Armourguard Low Sheen can be tinted to a wide range of colours. Apply Rendertex Rendershield or Armourguard as detailed in the current version of the Product Data Sheet.

Coverage for Rendershield will be up to 4-6 m2 per litre depending on the profile of the texture. Coverage for Armourguard will be up to 10 m2 per litre depending on the profile of the texture.

RENDERTEX RENDERSHIELD CLEAR

To maintain the sparkly finish in Sovereign Quartz, Rendertex Rendershield Clear must be used.

Rendershield Clear covers up to 105 m2 per 15 litre pail.

Apply two coats of Rendershield Clear as per the Product Data Sheet.

WARRANTY

The Haymes Rendertex system is covered by a material only replacement warranty for up to ten years subject to all products being correctly applied by experienced applicators on properly prepared substrate as recommended in Haymes Rendertex System Guides or per Project Specification, and compliance with other specified warranty terms. Among other things, the warranty applies only when complete Rendertex systems are used in accordance with Product Data Sheets and the Maintenance and Warranty Manual is adhered to. For a copy of our Warranty Statement, or our Maintenance and Warranty Manual, please see the Product Data Sheet supplied with the relevant Rendertex product or visit www.haymespaint.co.au/rendertex. To develop a more extensive project or commercial warranty contact your Haymes Regional Business Manager or Haymes Service Express on 1800 033 431.

For
Haymes Paint Head Office Waringa Drive, Wendouree Industrial Park, Ballarat, Victoria 3355 ABN 14 004 201 638 ACN 004 201 638 PO Box 167 Waringa Drive, Wendouree Victoria 3355 P: 1800 033 431 F: 1800 801 892 E: info@haymespaint.com.au W: haymespaint.com.au
more information or to find your local distributor please contact:
Information provided herein is considered correct at the time of publication. Colour may vary during the print process. It is the responsibility of those using this information to check that it is current prior to specifying or using any of the products or coating systems. Any advice, recommendation or information provided by any of the officers of Haymes Paint in relation to goods manufactured by it for their use and application, is given in good faith and is believed by Haymes Paint to be appropriate and reliable. However, this advice, recommendation and information is provided without liability or responsibility without excluding or limiting responsibility under relevant Government acts. Rendertex and other marks followed by the symbol ® or ™ are trademarks. RTX0098 V3. May, 2023.

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Uncoated Expanded Polystyrene Systems (EPS) by haymes_paint - Issuu