SS1.THEFABRICATORSHALLBERESPONSIBLEFORSHOPDRAWINGSWHICHSHALLCOMPLYWITHBOTENGINEERINGDRAWINGS.ANYVARIATION SHALLBEAPPROVEDBYBOTENGINEERINGPRIORTOFABRICATION.

SS2.WHERECONNECTIONFORCES(INKILO-NEWTONS)ARESHOWNONTHEDRAWINGS,CONNECTIONSSHALLBEPROVIDEDTOTRANSMITTHESE FORCES.CONNECTIONSSHALLPROVIDEFORAMINIMUMFORCEOF40kN.

SS3.UNO.ALLWELDSTOBE6mmCONTINUOUSFILLETSLAIDDOWNWITHAPPROVEDCOVEREDELECTRODESWITHANOMINALTENSILESTRENGTH OF490MPa..

SS4.UNO.ALLGUSSETPLATESTOBE10mmTHICK.

SS5.UNO.ALLBOLTSTOBEM20-8.8/SIN22mmDIAMETERHOLES.PROVIDEMINIMUMOFTWOBOLTSPERCONNECTION.

SS6.FABRICATORSHALLPROVIDEALLFIXINGSFORARCHITECTURALELEMENTSANDENSURETHEFIXINGDOESNOTADVERSELYIMPACTTHE STRUCTURALINTEGRITYOFTHEOVERALLSTRUCTUREORTHERESPECTIVEELEMENTISBEINGCONNECTEDTOO.

SS7.UNLESSOTHERWISENOTEDCAMBERSHALLBEPROVIDEDTOALLROOFBEAMS,TRUSSES,PORTALS.ATPER2000OFSPAN.NOMEMBER SHALLBEERECTEDWITHNEGATIVECAMBER.

SS8.ALLSTEELWORKBELOWGROUNDSHALLBEENCASEDBYMINIMUM75mmOFCONCRETE.

SS9.CONCRETEENCASEDSTRUCTURALSTEELTOBEWRAPPEDWITHFGW41PLACED25mmCLEAROFSTEEL. PROVIDE50mmMINIMUMENCASING.

SS10.ALLSTEELWORKNOTTOBEENCASEDINCONCRETESHALLBEGIVENONESHOPCOATOFANAPPROVEDPRIMERUNO.FACESOFFRICTION GRIPCONNECTIONSSHALLNOTBEPAINTED.

SS11.THEBOLTINGPROCEDUREDESIGNATEDASFOLLOWS:

-4.6/SREFERSTOCOMMERCIALBOLTSOFSTRENGTHGRADE4.6TOAS1111TIGHTENEDUSINGSTANDARDWRENCH TOSNUG-TIGHTCONDITION.

-8.8/S-REFERSTOHIGHSTRENGTHBOLTSOFSTRENGTHGRADE8.8TOAS1252TIGHTENEDUSINGASTANDARDWRENCHTOA SNUG-TIGHTCONDITION. -

-8.8/TF-REFERSTOHIGHSTRENGTHBOLTSOFSTRENGTHGRADE8.8TOAS1252FULLYTENSIONEDTOAS1511,DESIGNEDASFRICTION TYPEJOINT. -

-8.8/TB-REFERSTOHIGHSTRENGTHBOLTSOFSTRENGTHGRADE8.8TOAS1252FULLYTENSIONEDTOAS4100,DESIGNEDASABEARING TYPEJOINT.

SS12.ALLBOLTSSHALLBEOFSUCHLENGTHTHATATLEASTONEFULLTHREADEXPOSEDBEYONDTHENUTAFTERTHENUTHASBEEN TIGHTENED.

SS13.MINIMUMONEWASHERSHALLBEUSEDUNDERTHENUTINALLSITUATIONS.TIGHTENINGISCARRIEDOUTATTHEHEAD,ANADDITIONAL WASHERSHALLBEUSEDUNDERTHEHEAD.FORSLOTTEDHOLESUSEHARDENEDWASHERUNDERTHENUTANDBOLTHEAD.

SS14.UNO.,ALLMATERIALTOBE

-GRADE300PLUSHOTROLLEDPLATES,FLATS,ANGLESTOAS/NZS3678. -GRADE300PLUSUB,UC,PFCANDANGLES. -GRADE300WB,WC. -GRADEC350L0SHS,RHS,CHS. -GRADE350L0FORALLBENTPLATESANDMEMBERS.

SS15.MANUFACTURERSOFSTRUCTURALSTEELPRODUCEDTOTHEFOLLOWINGAUSTRALIANSTANDARDSMUSTBECERTIFIEDBYACRS (AUSTRALIANCERTIFICATIONAUTHORITYFORREINFORCINGSTEELSLTD)ORANEQUIVALENTTHIRDPARTYPRODUCTCERTIFICATIONSYSTEM ASMAYBEAPPROVEDINWRITINGBYTHESPECIFIER

SS16.SHEARSTUDSSHALLBEWELDEDINACCORDANCEWITHAS1554.2.UNO.ALLWELDSSHALLBE

SS17.HOTDIPPEDGALVANIZINGSHALLBEINACCORDANCEWITHAS4791,AS4792,AS1214,AS4680AS2312

SS18.HOTDIPGALVANSINGMINIMUMCOATINGTHICKNESSOF85MICRONS.

SS19.GALVANIZEDSTEELWORKTHATSITEWELDEDORSUSTAINSANYOTHERFORMOFSURFACEDAMAGEISTOBEPREPAREDTOAS1627.2 CLASSANDPRIMEDWITHCOATSOFGALVANISEORAPPROVEDANAPPROVEDHIGHZINCRICHPRIMERTOMANUFACTURER'S SPECIFICATION.

SS20.WELDINGSHALLBEPERFORMEDONLYBYWELDERSWITHQUALIFICATIONSASDESCRIBEDINAS1554SECTION4.12.2. SS21.WELDINGINSPECTIONSSHALLBEPERFORMEDBYANINDEPENDENTTESTINGAUTHORITYATTHECONTRACTORSEXPENSE.DEFAULTWELD TESTINGSHALLBEASFOLLOWS:ALLTESTINGSHALLBEINACCORDANCEWITHAS1554.1

D1.THESEDRAWINGSARETOBEREADINCONJUNCTIONWITHALLOTHERCONSULTANTS'DRAWINGS,ARCHITECTURALDRAWINGS,STRUCTURAL DRAWINGSANDSPECIFICATIONS

D2.INDICATIVECONFIGURATIONSOFEXISTINGSTRUCTURALELEMENTSREPRESENTEDONTHESEDRAWINGSAREBASEDONINFORMATION PRESENTEDONTHEEXISTINGCONDITIONSFLOORSPLANSPREPAREDBYTHEARCHITECTBASEDONSURVEYDRAWINGS.

D3.THECONTRACTORISRESPONSIBLEFORVERIFICATIONOFEXISTINGSTRUCTURALCONDITIONSPRIORTOCOMMENCEMENTOFDEMOLITIONOF EXISTINGSTRUCTURE.WHEREDISCREPANCIESARISEBETWEENDRAWINGSANDACTUALCONDITIONSENCOUNTEREDONSITE,THE CONTRACTORSHALLCONTACTBOTENGINEERINGFORFURTHERADVICE.

D4.THECONTRACTORMUSTTAKEALLNECESSARYPRECAUTIONSBEFOREANDDURINGDEMOLITIONWORKS.ALLPROPPINGORPROPRIETARY PRODUCTSUSEDDURINGTHEDEMOLITIONORCONSTRUCTIONPHASEMUSTBEINSTALLEDSTRICTLYINACCORDANCEWITHMANUFACTURERS DESIGNSPECIFICATIONSANDDESIGNMANUALS.

D5.ALLDEMOLITIONWORKSARETOBECARRIEDOUTACCORDANCEWITHAPPROVEDSEQUENCESTHATMAINTAINSTHESTRUCTUREINASAFE ANDSTABLECONDITIONATALLTIMES.

D6.ALLELECTRICALCABLESANDOTHERSERVICESSHALLBEDISCONNECTEDPRIORTOTHECOMMENCEMENTOFDEMOLITIONWORKS.

D7.THEWORKSITENEEDSTOHAVEADEQUATEPERIMETERPROTECTIONTOPREVENTUNAUTHORISEDPUBLICACCESSANDENSUREALL ADJOININGPROPERTIESAREADEQUATELYGUARDEDFROMLOOSEDEBRIS.

D8.PROPPINGANDSCAFFOLDSOLEPLATESMUSTBESIZEDTOEVENLYTRANSFERTHEAPPLIEDLOADSTOTHEFOUNDATION.

D9.ENSURETHATALLADJUSTABLEBASESORBASEPLATESAREINFULLCONTACTWITHTHEIRSUPPORTS.

D10.ITISRECOMMENDEDTOHAVENOTICESDISPLAYING'DANGERDEMOLITIONWORKSINPROGRESS'ORSIMILARARETOBEFIXED TOTHEHOARDING.

D11.THEEXTENTOFTHEDEMOLITIONOFEXISTINGSTRUCTURE(REPRESENTEDONTHESEDRAWINGS)ISINDICATIVEONLY.THECONTRACTORISTO REFERTOTHEARCHITECTURALDRAWINGSFORALLDIMENSIONALANDSETOUTINFORMATION.

D12.THEDEMOLITIONDRAWINGSPREPAREDBYBOTENGINEERINGSHOWTHEGENERALEXTENTOFDEMOLITIONANDIDENTIFIESWHERE PERMANENTSUPPLEMENTARYSUPPORTSTRUCTUREISREQUIREDTOFACILITATEDEMOLITIONANDTOMAINTAINTHESTRUCTURALINTEGRITY OFTHEEXISTINGSTRUCTURETHATREMAINSAFTERTHEDEMOLITIONWORKHASBEENCOMPLETED.

D13.NOWALL,CHIMNEYOROTHERSIMILARSTRUCTURESHALLBELEFTUNSUPPORTEDINSUCHADANGEROUSCONDITIONITMAYCOLLAPSEDUE TOWINDORVIBRATIONS.

D14.TEMPORARYPROPPINGDESIGNEDBYBOTENGINEERINGSHALLBEINSTALLEDWHERENECESSARYTOSUPPORTANYSTRUCTURALELEMENTS WHERETHEEXISTINGCONDITIONSHAVEBEENALTEREDDURINGTHEDEMOLITIONPHASE.

D15.THECONTRACTORISTOCO-ORDINATETHELOCATIONSIZEOFSERVICESPENETRATIONSPROVIDESETOUTFORREVIEWBYTHE STRUCTURALENGINEERPRIORTODEMOLITION.

D16.ITISTHECONTRACTOR'SRESPONSIBILITYTOUSEAPPROPRIATEDEMOLITIONSEQUENCES,PROCEDURESANDMETHODSTOENSURETHAT DEMOLITIONWORKSDONOTDISTURBORADVERSELYIMPACTTHESTRUCTURALINTEGRITYOFANYADJOININGPROPERTY.

D17.THECONTRACTORSHALLENSURETHESTRUCTUREREMAINSINASTABLECONDITIONATALLTIMES.

D18.ITISTHECONTRACTOR’SRESPONSIBILITYTOSECUREALLLOOSEANDUNSTABLEBUILDINGCOMPONENTSDURING THEDEMOLITIONPROCESS

D19.STRUCTURALELEMENTSTHATRESULTEXPOSEDREINFORCEMENTBEINGVISIBLEARETOBEPROTECTED/COATEDBYHIGHSTRENGTH EPOXYOREQUIVALENTPRODUCT.

TW1.TEMPORARYWORKSREQUIREMENTSDURINGCONSTRUCTIONPHASETHERESPONSIBILITYOFTHECONTRACTORANDDOESNOTFORMPART OFBOTENGINEERINGDESIGNPACKAGEUNLESSSEPARATELYAGREED.

TW2.THEDESIGN,FABRICATION,ERECTIONANDREMOVALOFALLTEMPORARYWORKSSHALLBETHERESPONSIBILITYOFTHECONTRACTOR BUILDERANDISTOBEDESIGNEDANDDOCUMENTEDBYSUITABLYQUALIFIEDENGINEER.

TW3.THEDESIGNMUSTCONSIDERTHETEMPORARYSTABILITYOFTHEPARTIALLYCOMPLETEDSTRUCTUREANDADJACENTINFRASTRUCTURE TAKINGINTOACCOUNTALLEXISTINGANDPROPOSEDBELOWGROUNDSERVICESANDAREAS.

TW4.PRIORTOCOMMENCINGTHEWORKSTHEBUILDER/CONTRACTORISTOINSTALLALLNECESSARYTEMPORARYSOLUTIONSANDBRACINGTO MAINTAINSTRUCTURALSTABILITYDURINGTHEWORKSANDTOENSURETHATTHESTRUCTUREDOESNOTBECOMEOVERSTRESSED, UNSTABLEORDAMAGEDDURINGTHEWORKS.

TW5.IFTHEREISREQUIREMENTTOTRANSFERLOADSINTOTHEPERMANENTSTRUCTURESTANYTIMEDURINGTHECONSTRUCTIONPHASE,THE BUILDER/CONTRACTORSHALLCOORDINATETHEPROPOSEDTEMPORARYDESIGNSOLUTIONANDPROVIDEENOUGHINFORMATIONAND COMPUTATIONSFORAPPROVALBYBOTENGINEERINGTHATTHEPERMANENTSTRUCTURECANADEQUATELYSUPPORTTHEINDUCEDLOADSIN

SS22.BUILDER/CONTRACTORTOALLOWFORTRIMMINGPURLINSTOHIPS,VALLEYS,OPENINGSTHATISNOTDIRECTLYSHOWNONPLANS.

SS23.REFERTOARCHITECTURALSPECIFICATIONSFORDURABILITYANDPAINTTREATMENTOFALLEXPOSEDSTEELWORK.UNO.ALLEXPOSED STEELWORKANDSTEELWORKINPOTENTIALLYCORROSIVEENVIRONMENTSHALLBEHOTDIPGALVANISED.

SS24.STEELWORKFIRERATINGREQUIREMENTSARETOMEETTHOSESPECIFIEDBYTHEBUILDINGSURVEYOR.

SS25.THESTRUCTUREHASBEENDESIGNEDFORTHEFINALCONDITIONONLY.ISTHEBUILDERS/CONTRACTOR'SRESPONSIBILITYTOENSURETHAT DURINGCONSTRUCTIONTHESTRUCTUREISMAINTAINEDINASTABLECONDITIONANDNOPARTOFTHESTRUCTUREISOVERSTRESSEDOR OVERLOADED

SS26.SUBSTITUTIONSFORSTEELSECTIONSSHOWNONDRAWINGSSHALLNOTBEMADEWITHOUTTHEWRITTENAPPROVALOFTHE SUPERINTENDENT.

SS27.ALLDETAILS,GAUGELINESETC,WHERENOTSPECIFICALLYSHOWNARETOBEINACCORDANCEWITHTHELATESTEDITIONOFTHEASIDESIGN CONNECTIONHANDBOOKANDASIDESIGNGUIDES.

SS28.ALLSTEELWORKSHARP/ROUGHEDGESTOBEGROUNDBACKTOSMOOTHSURFACE.

PRECASTWALLSCHEDULE(LOAD-BEARING)

RETAININGWALLSCHEDULE

PRECASTWALLSCHEDULE(LOAD-BEARING)

WALLSCHEDULE

SHED-FOUNDATIONANDFOOTINGPLAN

SCALE1:100INA0

SHED-GROUNDFLOORGENERALARRANGEMENTPLAN

SCALE1:100INA0

SHED-ROOFGENERALARRANGEMENTPLAN

SCALE1:100INA0

EXCAVATIONAREENCOUNTERED THEENGINEERSHALLBEADVISEDIMMEDIATELYANYGROUNDWATERISENCOUNTERED ONSITE,SOTHATADECISIONCANBEMADEASTOWHETHERLOCALDE-WATERINGIS REQUIRED GROUNDCONDITIONNOTES

GRIDLINEDIMENSIONSHAVEBEENSHOWNONLYASAGUIDEDURINGDESIGN DOCUMENTATIONSTAGE.FORALLDIMENSIONSANDSETOUTREQUIREMENTSREFERTO ARCHITECTURALDRAWINGSONLY.BOTDRAWINGSANDTHEDIMENSIONSSHOWNON THEPLANSARENOTTOBERELIEDONATANYTIME. REFERTOARCHITECTURAL'SFORALLFALLS,STEPS,LEVELS,INSULATIONAND WATERPROOFINGREQUIREMENTS. THECONTRACTOR/BUILDERANDALLCONSULTANTSARERESPONSIBLEFOR MAINTAININGTHESTRUCTUREANDANYADJACENTSTRUCTURESINSAFEANDSTABLE