3016 NE Blakeley St

Page 1

ELEMENT CYCLES

3016 NE BLAKELEY ST.

CONTACT INFORMATION

1

DETAIL REFERENCE ALIGN ALIGN WITH ESTABLISHED SURFACES

THERMOSTAT

SECTION REFERENCE

1

VICINITY MAP

ILLUMINATED EXIT SIGNAGE

not to scale

A#.#

BUILDING DATA:

8'-101 4"

30'-0" R.O.W

existing commercial abutter

61'-6" 60'-0"

19'-8"

PROJECT/CODE SUMMARY

DCI G1.0 G1.1 XXX

COVER SHEET GENERAL PROJECT INFORMATION STANDARD ADA ASSEMBLIES SURVEY

A0.1 A0.2 A0.3

AS BUILT PLAN, FLOOR 1 @ 1/4" = 1'-0" AS BUILT PLAN, FLOOR 2 @ 1/4" = 1'-0" AS BUILT PLAN, FLOOR 3 @ 1/4" = 1'-0"

A1.0

PROPOSED AVG GRADE CALC & EXITING PLANS @ 1/8" = 1'-0"

A2.0 A2.1 A2.2 A2.3

PROPOSED PLAN, FLOOR 1 @ 1/4" = 1'-0" PROPOSED PLAN, FLOOR 2 @ 1/4" = 1'-0" PROPOSED PLAN, FLOOR 3 @ 1/4" = 1'-0" PROPOSED PLAN, ROOF @ 1/4" = 1'-0"

A3.0 A3.1 A3.11 A3.2 A3.3

PROPOSED EXTERIOR WEST ELEVATION @ 1/4" = 1'-0" PROPOSED EXTERIOR SOUTH ELEVATION @ 1/4" = 1'-0" UNPROTECTED OPENINGS DIAGRAM PER 705.8 @ 1/4" = 1'-0" PROPOSED EXTERIOR EAST ELEVATION @ 1/4" = 1'-0" PROPOSED EXTERIOR NORTH ELEVATION @ 1/4" = 1'-0"

A4.0 A4.1

PROPOSED BUILDING SECTION @ 1/4" = 1'-0 DETAILED WALL SECTION @ 1-1/2" = 1'-0"

A5.0 A5.1 A5.2

ENLARGED WINDOW ELEVATIONS, FLOOR 1 @ 1/2" = 1'-0" ENLARGED WINDOW ELEVATIONS, FLOOR 2 @ 1/2" = 1'-0" ENLARGED WINDOW ELEVATIONS, FLOOR 3 @ 1/2" = 1'-0"

TRASH

FLOOR 1 SECONDARY ENTRANCE

ALL EXISTING PARKING SPACES TO REMAIN

DRAWING INDEX REFLECTED CEILING PLANS @ 1/8" = 1'-0" ENLARGED BATHROOM ELEVATIONS, FLOOR 2 @ 1/2" = 1'-0" ENLARGED BATHROOM ELEVATIONS, FLOOR 3 @ 1/2" = 1'-0"

A7.0 A7.1

TYPICAL DETAILS @ 3" = 1'-0" STRUCTURAL GLASS GUARDRAIL DETAILS

E-LAB ENTRY FLR 2

FOUNDATION PLAN @ 1/4" = 1'-0" SECOND FLOOR FRAMING PLAN @ 1/4' = 1'-0" THIRD FLOOR FRAMING PLAN @ 1/4' = 1'-0" ROOF FRAMING PLAN @ 1/4' = 1'-0"

S3.1 S3.2 S3.3

STRUCTURAL CONCRETE DETAILS STRUCTURAL CONCRETE DETAILS, CONTINUED STRUCTURAL CONCRETE DETAILS, CONTINUED

S4.1 S4.2 S4.3 S4.4 S4.5

STRUCTURAL FRAMING DETAILS STRUCTURAL FRAMING DETAILS, CONTINUED STRUCTURAL FRAMING DETAILS, CONTINUED STRUCTURAL FRAMING DETAILS, CONTINUED STRUCTURAL FRAMING DETAILS, CONTINUED

FLOOR 3: TENANT TBD; OPEN OFFICE SPACE B BUSINESS (w/ SPRINKLERS)

CLIMATE ZONE

5 & MARINE 4 Roofs

Insulation entirely above roof deck R-38ci Metal buildingsb 25 + R-22 LS Attic and other R-49 Walls, Above Grade Exterior R-16ci Mass Interior (wood stud) R-13 + R-6ci Interior (metal stud) R-13 + R-10ci R-19ci, or R-13 + R-13ci Metal building R-13 + R-10ci Steel framed R-13 + R-7.5 ci Wood framed and other Walls, Below Grade R-10ci Exterior R-19 Below-grade walld Interior (wood stud) R-13 + R-6ci Interior (metal stud) Floors R-30ci Mass Steel frame: R-38 + R-4ci Joist/framing Wood frame: R-38 Slab-on-Grade Floors R-10 for 24" below Unheated slabs Heated slabsd R-10 perimeter & under entire slab Opaque Doors Swinging U-0.37 Nonswinging; Roll-up or sliding U-0.34

CLIMATE ZONE 5 & MARINE 4 VERTICAL FENESTRATION U-factor 0.26 Nonmetal framing (all)a 0.31 0.38 Metal framing (fixed)b 0.38 0.40 Metal framing (operable)c 0.60 Metal framing (entrance doors)d 0.35 SHGC (SEW Orientation) SKYLIGHTS 0.45 U-factor 0.32 SHGC

EXISTING BATHROOMS (on third floor) TO BE REMODELED TO MEET ADA COMPLIANCE REQ'S MINIMUM FIXTURE PER OCCUPANT [PER SUITE]

existing conc.

23'-7"

34'-8"

PROPOSED INFILL/ADD.

x = 500 sf RETAIL/ OFFICE ADA ENTRY FLR 2

EXISTING BUILDING OVERHANG

ALL EXISTING PARKING SPACES TO REMAIN

B = 25 < 50; 1 per 25 for the first 50 = 1 WATERCLOSETS B = 25 < 40; 1 per 40 for the first 1,520 = 1 LAVATORY = 2 WATERCLOSETS & 2 LAVATORIES REQUIRED TOTAL FLOOR 3: (PROPOSED OFFICE SPACE) = 29 Occ.

76 78

DN 15'-0" 8'-41 2"

6'-4"

per Column 'B' of Table C402.4 (permit submitted prior to Jan 1st 2018)

DN

REMOVE EXISTING ROOF LADDER

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 4.88 kg/m2, 1 pound per cubic foot = 16 kg/m3. ci = Continuous insulation, NR = No requirement, LS = Liner system. a. Assembly descriptions can be found in Chapter 2 and Appendix A. b. Where using R-value compliance method, a thermal spacer block with a minimum R-value of 3.5 shall be provided, otherwise use the U-factor compliance method in Table C402.1.2. c. (Reserved) d. Where heated slabs are below grade, they shall comply with the insulation requirements for heated slabs. e. (Reserved) f. "Mass floors" shall include floors weighing not less than: 1. 35 pounds per square foot of floor surface area; or 2. 25 pounds per square foot of floor surface area where the material weight is not more than 120 pounds per cubic foot. g. For roof, wall or floor assemblies where the proposed assembly woudl not be continuous insulation, alternate nominal R-value compliance options for assemblies with isolated metal fasteners that penetrate otherwise continuous insulation are as shown in Columns B and C of Table C402.1.3(g).

REQUIRED EXITING PER OCCUPANCY GROUP PER FLOOR

84

EXISTING ROCKERY TO REMAIN

82

existing residential abutter 64'-0"

18 "

DE C

SITE PLAN NORTH

NOTES GENERAL NOTES Any specific reference to codes, rules, regulations, standards, manufacturer's instructions or requirements of regulatory agencies shall mean the latest printed edition of each is in effect at the date of submission or bid unless the document is shown dated. A copy of the approved plan must be on site whenever construction is in progress. Paved surfaces including roadways, sidewalks, and curbs that are damaged by new construction shall be repaired as required by the street use inspector. INTERPRETATIONS: These documents are in part diagrammatic and subject to interpretation. They do not necessarily show complete details of construction, work, or materials, performance or installation, and do not necessarily show how construction details of other items of the work may affect any particular installation, these must be ascertained by the contractor and correlated to bring the parts together as a completed whole. Any detail, dimension, or statement not completely clear to the contractor shall be referred to the architect for interpretation. DIMENSIONS: The drawings may not be drawn to scale in some instances; follow dimensions but do not scale drawings the work. All dimensions are given to the face of existing finish materials, and to the face of the studs at new construction unless noted otherwise. TREE PROTECTION:

STAIR NOTES:

Handrails shall be no less than 36 inches in height with a maximum spacing between intermediate rails to prevent passage of 4-inch sphere. Treads shall be a minimum of 11" deep and risers shall be a maximum of 7" high.

FLOOR 2 MAX ALLOWABLE 'M' TRAVEL DISTANCE TO EXIT (with sprinkler) (PER TABLE 1017.2) = 250' FLOOR 2 MAX ALLOWABLE 'B' TRAVEL DISTANCE TO EXIT (with sprinkler) (PER TABLE 1017.2) = 300' (E-LAB)

---> two exits

FLOOR 3 MAX ALLOWABLE 'B' TRAVEL DISTANCE TO EXIT (with sprinkler) (PER TABLE 1006.2.1) = 100'

---> one exit

REFER TO SHEET A6.0 FOR REFLECTED CEILING PLAN / FIXTURE INFO

FLOOR 1: FLOOR 2: FLOOR 3:

RETAIL = 1.01 W/SF (3875 SF)= RETAIL = 1.01 W/SF (3977 SF)= OFFICE = 0.66 W/SF (3752 SF)=

3,913.75 W 4,016.77 W 2,476.32 W

EMERGENCY LIGHTING per C405.3 Exit signs (mandatory). Internally illuminated exit signs shall not exceed 5 watts per side. PER C405.4.2(1) EXTERIOR LIGHTING (ZONE 3)

Stairways shall have a minimum clear width of 36" and ceilings shall be a minimum of 6'-8" vertically above nosing Outdoor stairs and their approaches shall be designed so that water will not accumulate on walking surfaces INSURANCE: The contractor shall carry comprehensive general liability insurance in the amount of $1,000,000 combined single limit bodily injury and property damage.

ADDITIONAL ENERGY REQUIREMENTS:

1

The contractor shall provide certificate of insurance naming owner and architect as additional insured at contract signing. The owner shall carry standard course of construction coverage for fire, theft and owner liability. PROTECTION OF EXISTING PROPERTY: The contractor shall take all necessary precautions to avoid damage to existing property to remain, including masking adjacent surfaces, and constructing fences or barricades.

PER C503.8.3, ENERGY EFFICIENCY; FOR BUILDINGS UNDERGOING SUBSTANTIAL ALTERATION: SECTION C503.4.6, NEW AND REPLACEMENT HVAC HEATING SYSTEM EQUIPMENT PER C406.1 REQUIREMENTS. BUILDINGS SHALL COMPLY WITH NO LESS THAN TWO LISTED. (we propose the following two from C406.1 requirements):

The contractor shall take the same precautions to avoid damage to landscape as with other property.

08/08/2017 CLEAN UP: Keep the premises clean and orderly as required for safety and efficient performance of the work.

Fencing must be kept in place for the duration of construction

Pick up underfoot daily. Haul off debris approximately weekly or arrange for dumpster to remain at the site.

No soil disturbance or activity allowed within fenced area, such as but not limited to: material storage / stockpiling, trenching / tunneling, parking, dumping or washing

---> two exits

Walls and soffits of enclosed usable space underneath stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction.

Fencing must be installed prior to demolition and ground disturbance Modifications to fencing by approval of project planner only (206.386.1357)

FLOOR 1 MAX ALLOWABLE 'M' TRAVEL DISTANCE TO EXIT (with sprinkler) (PER TABLE 1017.2) = 250'

PER C405.4.2(1) INTERIOR LIGHTING

Refer to DCI CSC sheet for additional information Tree Protection Fencing required around entire drip line on the permit site plan (the Tree Protection Area - TPA)

(per SBC 1017.2)

ILLUMINATION DATA:

SCALE: 3/32" = 1'-0"

Footnotes for Table C402.4

Footnotes for Table C402.1.3

EGRESS DATA:

ROCKERY PORTION TO BE REMOVED 26'-31 2"

29'-4"

44'-03 4" EXISTING COTTONWOOD TO BE REMOVED

10'-0" SETBACK

DN

B = 29 < 50; 1 per 25 for the first 50 = 2 WATERCLOSETS TOTAL B = 29 < 40; 1 per 40 for the first 1,520 = 1 LAVATORY TOTAL

NEW EXTERIOR STAIR TO THIRD FLR

4'-8"

4'-8" 15'-0"

10'-0" SETBACK

DN

15'-0" RESIDENTIAL SETBACK

a. "Nonmetal framing" includes framing materials other than metal, with or without metal reinforcement or cladding. b. "Metal framing" includes metal framing, with or without thermal break. "Fixed" includes curtain wall, storefront, picture windows, and other fixed windows. c. "Metal framing" includes metal framing, with or without thermal break. "Operable" includes openable fenestration products other than "entrance doors." d. "Metal framing" includes metal framing, with or without thermal break. "Entrance door" includes glazed swinging entrance doors and automatic glazed sliding entrance doors. Other doors which are not entrance doors, including sliding glass doors, are considered "operable."

(per SBC 2902.1)

M = 95/500 = 0.19 95/750 = 0.13

REMOVE EXIST. SITE STEPS

PROP. BICYCLE PARKING

1

3,875 SF TOTAL 3741 SF / 130 GROSS FACTOR = 28.78 Occ. 29 Occ.

FIXTURE / EQUIPMENT DATA:

PROP BIKE PARKING

FLOOR 1 MAIN ENTRY

DASHED LINE INDICATES SUBLOT DIVISION

TABLE C402.4 BUILDING ENVELOPE REQUIREMENTS -- FENESTRATION

3,977 SF TOTAL 2412.9 SF / 60 GROSS FACTOR = 40.2 Occ. 40 Occ. BUSINESS (w/ SPRINKLERS) 1229.1 SF / 50 GROSS FACTOR = 24.6 Occ. *E-LAB is an Exercise Room < 50 Occupants 25 Occ.

FLOOR 1 & 2: ELEMENT CYCLES (PROPOSED SUITE) for Occupancy Group M = 95 Occ.

REMOVE EXISTING SITE STEPS

TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHODa

3,875 SF TOTAL 3161.0 SF / 60 GROSS FACTOR = 52.7 Occ. 490.7 SF / 300 GROSS FACTOR = 1.64 Occ. 55 Occ.

existing conc.

64'-9" 4'-0"

existing conc.

ENERGY CODE

(per SBC 1004.1.2)

55 + 40 + 25 = 120 Occupant Load for Floor 1 & 2

14'-8"

S2.1 S2.2 S2.3 S2.4

PROP. NEW ROOF

69'-5"

STRUCTURAL GENERAL NOTES STRUCTURAL GENERAL NOTES, CONTINUED

B

EXISTING 3 STORY WOOD FRAME BUILDING FOOTPRINT

PROP. LOWER AWNING

HYD2100R ELEVATOR NOTES & DRAWINGS S1.1 S1.2

RECYCLE

FLOOR 1: ELEMENT CYCLES, LLC M (MERCANTILE) S-2 (STORAGE)

EXISTING DECK & COLUMNS TO REMAIN 3016 NE BLAKELEY ST

70

OCCUPANT LOAD PER PROPOSED SUITE AREA BREAKDOWN

NEW SCREENED TRASH ENCLOSURE

1

V-B (w/ SPRINKLERS)

FLOOR 2: ELEMENT CYCLES, LLC M (MERCANTILE)

EXISTING PLANTER TO REMAIN A6.0 A6.1 A6.2

CONSTRUCTION TYPE:

1

EXISTING BUILDING OVERHANG

ALL WORK TO COMPLETED IN COMPLIANCE WITH THE NEWEST VERSION OF THE FOLLOWING CODES AND REGULATIONS AS REQ'D

1

16'-0" EXISTING ALLEY

71 2"

4'-8"

2015 UNIFORM PLUMBING CODE 2014 NATIONAL ELECTRIC CODE 2015 SEATTLE ENERGY CODE

number

FIRE VALVE CABINET

A#.#

(3.25) 7,206.10 sf = 23,419.825

2015 SEATTLE BUILDING CODE 2015 SEATTLE FIRE CODE 2015 SEATTLE MECHANICAL CODE

FIRE VALVE WITHOUT CABINET

FV EQUIPMENT TAG / REFERENCE

1

3016 NE BLAKELY STREET SEATTLE, WA 98105

FAR:

FIRE EXTINGUISHER CABINET

1

TO NEW RETAIL BIKE SHOP (FLOORS 1 & 2); OFFICE (FLOOR 3)

FINISH TAG / REFERENCE

ELEMENT CYCLES

Rear and Side: NO residential Rear and Side: WITH residential One-half of the width of an abutting alley may be counted as part of the required setback. For the purpose of this Section 23.47A.014, the alley width and the location of the rear lot line shall be determined prior to any dedication that may be required for alley improvement purposes.

CPT-1

FIRE EXTINGUISHER WITHOUT CABINET

17-06

A#.#

per 23.47A.014

Front: The required setback forms a triangular area. Two sides of the triangle extend along the street lot line and side lot line 15 feet from the intersection of the residentially zoned lot's front lot line and the side lot line abutting the residentially zoned lot. The third side connects these two sides with a diagonal line across the commercially-zoned lot.

TENANT IMPROVEMENT: CHANGE OF USE FROM WAREHOUSE/OFFICE (FLOORS 1 & 2); LIGHT MANUFACTURING (FLOOR 3)

EXTERIOR ELEVATION REFERENCE

08/08/2017 10/16/2017

SETBACKS:

KEYNOTE REFERENCE FE

1

EXCEPT THE SOUTHWESTERLY 10 FEET THEREOF CONDEMNED IN KING COUNTY SUPERIOR COURT CAUSE NO. 74496 FOR WIDENING OF RAILROAD AVENUE, AS PROVIDED BY ORDINANCE 22601 OF THE CITY OF SEATTLE. SCOPE:

1

permit intake submittal permit corrections 1

NO CHANGE

PROJECT NOTES & INFORMATION

PARKING:

FIRE HOSE CABINET

project

40 Feet

A#.#

Remodel for:

HEIGHT LIMIT:

INTERIOR ELEVATION REFERENCE

ENLARGED PLAN REFERENCE

DATE

7,206.10 SF

A#.#

WALL / ASSEMBLY REFERENCE

1

1 4

LOT SIZE:

NEW PARTITION

1

REVISION

LOTS 30 AND 31, BLOCK 5, EXPOSITION HEIGHTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 15 OF PLATS, PAGE 83, IN KING COUNTY, WASHINGTON;

C1-40

EXISTING CONSTRUCTION TO DEMOLISHED

REVISION CLOUD

#

LEGAL:

3016 NE BLAKELEY ST. 243620-0630

ZONING:

COLUMN GRID

Issue

ADDRESS: TAX I.D. #:

1

ZONING INFORMATION

6585763

NEW METAL LAMINATE FRAME AND/OR MDF WALL.

A

2

DPD PROJECT# :

EXISTING CONSTRUCTION TO REMAIN

NORTH ARROW

3

PROJECT INFORMATION

STRUCTURAL ENGINEER SWENSON SAY FAGET CONTACT: CHRIS POTTER 932 BROADWAY TACOMA, WA 98402 (253) 284-1685 -phone cpotter@swensonsayfaget.com

PERMIT

DESIGNER RYAN RHODES DESIGNS, INC. CONTACT: RYAN RHODES 303 NICKERSON ST SEATTLE, WA 98109 (206) 632-1818 -phone ryan@ryanrhodesdesigns.com

1

TENANT ELEMENT INVESTMENTS, LLC CONTACT: DENNIS WEIBLING 2205 CARILLON POINT KIRKLAND, WA 98033 (425)-889-4331 -phone dennis@rallycapllc.com

SYMBOL LEGEND

sheet

G1.0 number


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
3016 NE Blakeley St by Greener4588 - Issuu