Display access and settings

Once the inverter has been commissioned, it is possible/necessary to configure the inverter by accessing the Settings Menu directly from the display. The following are the main adjustable parameters (see the section on “Menu descriptions”) • RS485 address: setting required in the case of system monitoring via the RS485 line • Vstart: setting required if requested by the configurator during the system sizing procedure ("Vstart" parameter) • MPPT scan: allows maximum power point tracking with settable sensitivity and time interval ("MPPTScan EN/DIS" parameter). • Reactive power feed-in setting (where present): setting necessary for managing the different ways of feeding reactive power into the grid (“Reactive Power" parameter) • Active power limitation setting (where present): setting necessary to set a limit on the active power supplied by the inverter (“Power reduction” parameter)