Rinnai

Page 1

To Request a Quote, Please Contact Us:

Tankless Water Heaters

828-735-1978 or 828-538-4311 sales@jxtcompany.com

HIGH-EFFICIENCY (NONCONDENSING TECHNOLOGY)

SUPER-HIGH-EFFICIENCY (CONDENSING TECHNOLOGY)

HE Series

HE+ Series

SE Series

( V MODELS )

( RL MODELS )

( RUCS/RUS MODELS )

(RU MODELS )

( RUR MODELS )

0.81

0.81-0.82

0.85-0.90

0.91-0.93

0.93

AVAILABLE IN NATURAL GAS OR PROPANE

3

3

3

3

3

INDOOR AND OUTDOOR VERSIONS AVAILABLE

3

3

3

3

3

UNIFORM ENERGY FACTOR

SENSEI™ SE+ Series

WI-FI READY

RECIRCULATION SOLUTION MADE POSSIBLE WITH CIRC-LOGICTM TECHNOLOGY

3

3

3

ISOLATION VALVES

3

3

3

THERMACIRC360TM — (RECIRC WITH OR WITHOUT DEDICATED LINE)

3

INCLUDES CONTROL-R™ WI-FI MODULE FOR RECIRCULATION CONTROL

3

Key Benefits • •

• •

Never think about hot water again. Available in multiple sizes, our innovative technology provides an endless supply of hot water whenever and wherever it’s needed – even for simultaneous multiple fixtures. Minimum output. Maximum space. About the size of a small suitcase, the Rinnai can be tucked in a small crawl space, attic or basement. These wall-mounted units can be installed on the interior wall of the home to free up valuable space. Earth-friendly efficiency. Compact heat exchanger design, longer product lifespan compared to a traditional tank and recyclable parts means less waste in landfills. Vertically integrated. All key components are manufactured and assembled by Rinnai – for the highest quality you have come to expect from these products. 2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


NEW! SENSEI SE+ and SE Series Condensing Tankless Water Heater New SENSEI™ Tankless Water Heaters, with an enhanced combustion system, provide all the traditional benefits of a Rinnai, but with a better experience for installers and users. SENSEI provides an endless supply of hot water, energy savings, a space saving design and environmentally friendly features. Rinnai’s dual heat exchanger and condensing technology provides up to a .93 Uniform Energy Factor, ENERGY STAR® certification and up to 40 percent less energy use* than a traditional tank. New Features • Accepts 2" dual pipe or concentric venting • Flexible gas intake allowing for 1/2-inch gas line with zero governor gas valve • Longest 2" vent runs - up to 65' available with new turbo fan feature • Enhanced freeze protection via vent check valves • New rotating isolation valve and adjustable mounting bracket

Tankless Water Heater Changes Max BTU Input

Existing Part Number

New Part Number

199,000

RUC98i / RU98e

RU199i/e

180,000

RUC90i / RU90e

RU180i/e

160,000 Residential (Indoor / Outdoor)

Commercial (Indoor / Outdoor)

RU160i/e

152,000

RUC80i / RU80e

130,000

New

RU130i/e

199,000

RUR98i / RUR98e

RUR199i/e

160,000

New

RUR160i/e

199,000

C199i / C199e

CU199i/e

160,000

New

CU160i/e

SE+ Series (Legacy Models) Condensing Tankless Water Heater (While Supplies Last) High Efficiency, HE+ and HE Series Non-Condensing Tankless Water Heater Rinnai HE and HE+ Series Tankless Water Heaters, our non-condensing line of tankless water heaters, provide homeowners with an endless supply of hot water, energy savings, a compact design and environmentally friendly features. These units provide a .81 Uniform Energy Factor, and up to 40 percent less energy use* than a traditional tank.

* As based on the average cost to run an electric tank water heater per the Department of Energy (DOE) Average Energy Costs (doe.gov) 2017.

2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


SENSEI™ Tankless Water Heaters (Condensing) With an enhanced combustion design, the Rinnai SENSEI Tankless Water Heater provides a better experience for both users and installers. Like all Rinnai Tankless Water Heaters, it’s also vertically integrated. That means all key components are manufactured by Rinnai — to ensure Rinnai quality.

SENSEI™ SE+ Series (Replaces Previous SE+ Series) Model Number

Product Description

Product Dimensions (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

RU130iN

Indoor CTWH 130k Btu 7 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 7 GPM 1 l/min to 26 l/min

0.91/0.95

15,000

130,000

$1,574

RU130iP

Indoor CTWH 130k Btu 7 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 7 GPM 1 l/min to 26 l/min

0.91/0.95

15,000

130,000

$1,574

RU130eN

Outdoor CTWH 130k Btu 7 GPM max w/Valve

14.76 x 33.86 x 22.05

71

0.26 GPM to 7 GPM 1 l/min to 26 l/min

0.92/0.95

15,000

130,000

$1,574

RU130eP

Outdoor CTWH 130k Btu 7 GPM max w/Valve

14.76 x 33.86 x 22.05

71

0.26 GPM to 7 GPM 1 l/min to 26 l/min

0.92/0.95

15,000

130,000

$1,574

RU160iN

Indoor CTWH 160k Btu 9 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.95

15,000

160,000

$1,718

RU160iP

Indoor CTWH 160k Btu 9 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.95

15,000

160,000

$1,718

RU160eN

Outdoor CTWH 160k Btu 9 GPM max w/Valve

14.76 x 33.86 x 22.05

71

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.96

15,000

160,000

$1,718

RU160eP

Outdoor CTWH 160k Btu 9 GPM max w/Valve

14.76 x 33.86 x 22.05

71

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.96

15,000

160,000

$1,718

RU180iN

Indoor CTWH 180k Btu 10 GPM max w/Valve

74

0.26 GPM to 10 GPM 1 l/min to 38 l/min

0.93/0.95

15,000

180,000

$1,886

14.76 x 33.86 x 22.05

2018 SUGGESTED LIST PRICE (USD) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


SENSEI™ SE+ Series Condensing Tankless Water Heaters (Replaces Previous SE+ Series) Cont’d Model Number

Product Description

Product Dimensions (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

RU180iP

Indoor CTWH 180k Btu 10 GPM max w/Valve

14.76 x 33.86 x 22.05

74

0.26 GPM to 10 GPM 1 l/min 38 l/ min

0.93/0.95

15,000

180,000

$1,886

RU180eN

Outdoor CTWH 180k Btu 10 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 10 GPM 1 l/min to 38 l/min

0.93/0.96

15,000

180,000

$1,886

RU180eP

Outdoor CTWH 180k Btu 10 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 10 GPM 1 l/min to 38 l/min

0.93/0.96

15,000

180,000

$1,886

RU199iN

Indoor CTWH 199k Btu 11 GPM max w/Valve

14.76 x 33.86 x 22.05

74

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,054

RU199iP

Indoor CTWH 199k Btu 11 GPM max w/Valve

14.76 x 33.86 x 22.05

74

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,054

RU199eN

Outdoor CTWH 199k Btu 11 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,054

RU199eP

Outdoor CTWH 199k Btu 11 GPM max w/Valve

14.76 x 33.86 x 22.05

73

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,054

2018 SUGGESTED LIST PRICE (USD) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


FEATURING

SENSEI™ SE+ Series with ThermaCirc360™ Condensing Tankless Water Heaters (Replaces Previous SE+ Series) Cont’d SENSEI™ SE+ Series with ThermaCirc360™ Model Number

Product Description

Product Dimensions (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

RUR160iN

Indoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

83

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.95

15,000

160,000

$2,250

RUR160iP

Indoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

83

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.95

15,000

160,000

$2,250

RUR160eN

Outdoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

81

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.96

15,000

160,000

$2,250

RUR160eP

Outdoor CTWH 160k Btu 9 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

81

0.26 GPM to 9 GPM 1 l/min to 34 l/min

0.93/0.96

15,000

160,000

$2,250

RUR199iN

Indoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

84

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,558

RUR199iP

Indoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

84

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,558

RUR199eN

Outdoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

83

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

$2,558

RUR199eP

Outdoor CTWH 199k Btu 11 GPM max pump valve; 14.76 x 33.86 x 22.05 Includes Control-R™ Wi-Fi Module

83

0.26 GPM to 11 GPM 1 l/min to 42 l/min

0.93/0.96

15,000

199,000

WirelessModule_Included_sticker_5-press.pdf

C

M

Y

CM

MY

CY

CMY

K

Wi-Fi Ready

2

$2,558 9/28/18

5:28 PM

Everything You Need for Control of Recirculation, Right in the Box.

CONTROL-R™ RECIRCULATION MODULE INCLUDED (PN: RWM101) The Control-R™ Module must be installed to control recirculation.

NOTES:

• Control-R™ Wi-Fi Module included with SENSEI™ RUR models.

• Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. • For residential applications, the heat exchanger warranty will be 15 years or 12,000 operation hours, whichever occurs first. Note: From date of purchase, period of coverage is reduced to 8 years or 12,000 operation hours, whichever occurs first, if the Rinnai water heater temperature settings exceeds 160° F (71°C). • The integrated controller has a 1 year warranty on parts. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 6 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


SENSEI™ Series for Commercial Applications (Replaces Previous C199) Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

List Price (U.S.)

CU199iN

Commercial Indoor CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 31.3

64

22.1 x 14.8 x 33.9

74

97%

$2,200

CU199iP

Commercial Indoor CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 31.3

64

22.1 x 14.8 x 33.9

74

97%

$2,200

CU199eN

Commercial Outdoor CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 28.4

64

22.1 x 14.8 x 33.9

72

97%

$2,200

CU199eP

Commercial Outdoor CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 28.4

64

22.1 x 14.8 x 33.9

72

97%

$2,200

CU160eN

Commercial Outdoor CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 28.4

62

22.1 x 14.8 x 33.9

71

97%

$1,864

CU160eP

Commercial Outdoor CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 28.4

62

22.1 x 14.8 x 33.9

71

97%

$1,864

CU160iN

Commercial Indoor CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 31.3

62

22.1 x 14.8 x 33.9

72

97%

$1,864

CU160iP

Commercial Indoor CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 31.3

62

22.1 x 14.8 x 33.9

72

97%

$1,864

NOTES: • MCC-91 temperature controller included with commercial units.

2018 SUGGESTED LIST PRICE (USD) • Page 7 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Tankless Water Heaters Rinnai Tankless Water Heaters deliver innovation and technological leadership in Tankless Water Heating design while providing homeowners and businessowners with an endless supply of hot water, energy savings, a space saving design and environmental benefits. Rinnai offers ease of installation now with more venting options right out to the box.

SE+ Series with ThermaCirc360™ (Legacy Condensing Models) Model Number

Product Description

Product Dimensions - Inches (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/Legacy EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

82

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,798

0.92/0.95

15,200

199,000

$2,798

RUR98iN

Indoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34 x 22 Pass w/Valve

RUR98iP

Indoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34x22 Pass w/Valve

82

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

RUR98eN

Outdoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34 x 22 Pass w/Valve

82

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,798

RUR98eP

Outdoor CTWH 199k Btu 9.8 GPM max Deluxe Controller Thermal By 14.5 x 34 x 22 Pass w/Valve

82

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,798

(Limited Quantities)

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. • Full Freight Allowed for 16 pc. and greater, freight added to invoice for less than 16 pc. • When ordering, please specify gas type with a “P” for Propane and a “N” for Natural Gas. • All RUR Legacy Condensing models include a MC-195T-US Temperature Controller • All units, with the exception of RUR models, that are used for applications requiring temperatures above 140°F will require an MCC-91-2W controller (sold separately). RUR models cannot be used in applications exceeding 140°F. • All Product comply with California Lead-Free AB1953 Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 8 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


SE+ Series (Legacy Condensing Models) Model Number

Product Description

Product Dimensions - Inches (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/ Legacy EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

RUC80iN

Indoor CTWH 157k Btu 8.0 GPM max w/Valve

14.5 x 34 x 22

69

0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min

0.92/0.96

15,200

152,000

$1,718

RUC80iP

Indoor CTWH 157k Btu 8.0 GPM max w/Valve

14.5 x 34 x 22

69

0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min

0.92/0.96

15,200

152,000

$1,718

RUC90iN

Indoor CTWH 180k Btu 9.0 GPM max w/Valve

14.5 x 34 x 22

71

0.26 GPM to 9.0 GPM 1 l/min to 29 l/min

0.92/0.96

15,200

180,000

$1,886

RUC90iP

Indoor CTWH 180k Btu 9.0 GPM max w/Valve

14.5 x 34 x 22

71

0.26 GPM to 9.0 GPM 1 l/min to 29 l/min

0.92/0.96

15,200

180,000

$1,886

RUC98iN

Indoor CTWH 199k Btu 9.8 GPM max w/Valve

14.5 x 34 x 22

76

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,054

RUC98iP

Indoor CTWH 199k Btu 9.8 GPM max w/Valve

14.5 x 34 x 22

76

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,054

RU80eN

Outdoor 152K Btu max flow 8.0 GPM w/Valve

14.5 x 34 x 22

67

0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min

0.92/0.96

15,200

152,000

$1,718

RU80eP

Outdoor 152K Btu max flow 8.0 GPM w/Valve

14.5 x 34 x 22

67

0.26 GPM to 8.0 GPM 1 l/min to 30.3 l/min

0.92/0.96

15,200

152,000

$1,718

RU90eN

Outdoor CTWH 180k Btu 9.0 GPM max w/Valve

14.5 x 34 x 22

71

0.26 GPM to 9.0 GPM 1 l/min to 29 l/min

0.92/0.96

15,200

180,000

$1,886

RU90eP

Outdoor CTWH 180k Btu 9.0 GPM max w/Valve

14.5 x 34 x 22

71

0.26 GPM to 9.0 GPM 1 l/min to 29 l/min

0.92/0.96

15,200

180,000

$1,886

RU98eN

Outdoor 199K Btu max flow 9.8 GPM w/Valve

14.5 x 34 x 22

74

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,054

RU98eP

Outdoor 199K Btu max flow 9.8 GPM w/Valve

74

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.92/0.95

15,200

199,000

$2,054

14.5 x 34 x 22

NOTES: • All RUC Indoor units, with exception of RUCS, include an integrated MC-91-2US controller, 98° - 140°F. (Factory Setting 120°F) / RUCS has built-in status monitor. • All RU Outdoor units, with exception of RUS, include an MC-91-2US controller in the box, 98° - 140°F. (Factory Setting 120°F) / RUS has built-in status monitor. • SE+ Series Legacy Condensing models (exluding RUR models) include a MC-91-2US Temperature Controller

2018 SUGGESTED LIST PRICE (USD) • Page 9 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


SE Series (Condensing Models) Model Number

RUCS65iN

RUCS65iP

Product Description

Product Dimensions - Inches (W x H x D)

Indoor CTWH 160K Btu 6.5 GPM 14.5 x 34 x 22

Indoor CTWH 160K Btu 6.5 GPM 14.5 x 34 x 22

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/ Legacy EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

63

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.85/0.93

10,300

130,000

$1,362

63

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.85/0.93

10,300

130,000

$1,362

RUS65eN

Outdoor CTWH 160K Btu 6.5 GPM

14.5 x 34 x 22

62

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.86/0.93

10,300

130,000

$1,362

RUS65eP

Outdoor CTWH 160K Btu 6.5 GPM

14.5 x 34 x 22

62

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.86/0.93

10,300

130,000

$1,362

RUCS75iN

Indoor CTWH 160K Btu 7.5 GPM

14.5 x 34 x 22

63

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.90/0.93

10,300

160,000

$1,572

RUCS75iP

Indoor CTWH 160K Btu 7.5 GPM

14.5 x 34 x 22

63

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.90/0.93

10,300

160,000

$1,572

RUS75eN

Outdoor CTWH 160K Btu 7.5 GPM 14.5 x 34 x 22

63

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.89/0.93

10,300

160,000

$1,572

RUS75eP

Outdoor CTWH 160K Btu 7.5 GPM 14.5 x 34 x 22

63

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.89/0.93

10,300

160,000

$1,572

NOTES: • All RUC Indoor units, with exception of RUCS, include an integrated MC-91-2US controller, 98° - 140°F. (Factory Setting 120°F) / RUCS has built-in status monitor. • All RU Outdoor units, with exception of RUS, include an MC-91-2US controller in the box, 98° - 140°F. (Factory Setting 120°F) / RUS has built-in status monitor.

2018 SUGGESTED LIST PRICE (USD) • Page 10 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


HE+ Series (Non-Condensing) Model Number

Product Description

Product Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/ Legacy EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

RL75iN

Indoor 180k Btu 7.5 GPM max w/Valves

13 x 31 x 17.5

49

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,503

RL75iP

Indoor 180k Btu 7.5 GPM max w/Valve

13 x 31 x 17.5

49

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,503

RL75eN

Outdoor 180k Btu 7.5 GPM max w/Valve

13 x 31 x 17.5

49

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,503

RL75eP

Outdoor 180k Btu 7.5 GPM max w/Valve

13 x 31 x 17.5

49

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,503

RL94iN

Indoor 199k Btu 9.4 GPM max w/ Valve

13 x 31 x 17.5

54

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,828

RL94iP

Indoor 190k Btu 9.4 GPM max w/ Valve

13 x 31 x 17.5

54

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,828

RLX94iN

Indoor 192k Btu 9.8 GPM max w/ Valve

13 x 31 x 17.5

55

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.82/0.82

10,300

192,000

$1,828

RL94eN

Outdoor 199k Btu 9.4 GPM max w/Valve

13 x 31 x 17.5

54

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,828

RL94eP

Outdoor 190k Btu 9.4 GPM max w/Valve

54

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,828

13 x 31 x 17.5

2018 SUGGESTED LIST PRICE (USD) • Page 11 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


HE Series (Non-Condensing) Model Number

Product Description

Product Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Hot Water Capacity Range

UEF/ Legacy EF

Min Heating Input (Btu/h)

Max Heating Input (Btu/h)

List Price (U.S.)

V53eN

Residential, Outdoor, max Btu 120,000, 5.3 GPM (Superceeded by V53DeN)

18.5 x 27 x 10.5

39

0.6 GPM to 5.3 GPM 2.3 l/min to 20.1 l/min

0.81/0.82

19,000

120,000

$899

V53eP

Residential, Outdoor, max Btu 120,000, 5.3 GPM (Superceeded by V53DeP)

18.5 x 26.5 x 10.5

39

0.6 GPM to 5.3 GPM 2.3 l/min to 20.1 l/min

0.81/0.82

20,200

120,000

$899

V53DeN

Residential, Outdoor, max Btu 120,000, 5.3 GPM

18.5 x 27.4 x 11.8

33

0.4 GPM to 5.3 GPM 1.5 l/min to 20 l/min

0.81/0.82

15,500

120,000

$899

V53DeP

Residential, Outdoor, max Btu 120,000, 5.3 GPM

18.5 x 27.4 x 11.8

33

0.4 GPM to 5.3 GPM 1.5 l/min to 20 l/min

0.81/0.82

15,500

120,000

$899

V65iN

Residential, Indoor, max. Btu 150,000, 6.3 GPM

13 x 30 x 17.5

50

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.80/0.82

10,300

150,000

$1,101

V65iP

Residential, Indoor, max. Btu 150,000, 6.3 GPM

17.32 x 30.51 x 12.8

50

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.80/0.82

10,300

150,000

$1,101

V65eN

Residential, Outdoor, max. Btu 150,000, 6.3 GPM

13 x 30 x 17.5

47

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.79/0.82

10,300

150,000

$1,023

V65eP

Residential, Outdoor, max. Btu 150,000, 6.3 GPM

17.32 x 30.51 x 13

47

0.26 GPM to 6.5 GPM 1 l/min to 24.6 l/min

0.79/0.82

10,300

150,000

$1,023

V75iN

Residential, Indoor, max. Btu, 180,000, 7.5 GPM

13 x30 x17.5

50

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.80/0.82

10,300

180,000

$1,345

V75iP

Residential, Indoor, max. Btu, 180,000, 7.5 GPM

12.8 x 30.51 x 17.32

50

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,345

V75eN

Residential, Outdoor, max. Btu, 180,000, 7.5 GPM

13 x 30 x 17.5

47

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,345

V75eP

Residential, Outdoor, max. Btu, 180,000, 7.5 GPM

12.8 x 30.51 x 17.32

47

0.26 GPM to 7.5 GPM 1 l/min to 28.4 l/min

0.81/0.82

10,300

180,000

$1,345

V94iN

Residential, Indoor, max. Btu, 199,000, 9.8 GPM

13 x 30 x 17.5

50

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,579

V94iP

Residential, Indoor, max. Btu, 199,000, 9.8 GPM

13 x 31 x 17.5

50

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,579

V94XiN

Residential, Indoor, max. Btu 192,000, 9.8 GPM

13 x 31 x 17.5

50

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.82/0.82

10,300

192,000

$1,579

V94eN

Residential, Outdoor, max. Btu, 199,000, 9.8 GPM

13 x 30 x 17.5

48

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,579

V94eP

Residential, Outdoor, max. Btu, 199,000, 9.8 GPM

13 x 30 x 17.5

48

0.26 GPM to 9.8 GPM 1 l/min to 37.1 l/min

0.81/0.82

10,300

199,000

$1,579

NEW

NEW

NOTES: • V53 models only with status indicator; no controller

2018 SUGGESTED LIST PRICE (USD) • Page 12 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Accessories for Tankless Water Heaters Controllers Product ID

Product Description

List Price (U.S.)

RWM101

Control-R™ Wi-Fi Module

$125

MC-91-2S

Temperature Controller Silver

$89

MC-91-2W

Temperature Controller White

$89

MCC-91-2W

Commercial Temperature Controller White

$120

BC-100V-1S

Bath Controller Silver (limited quantity)

$145

BC-100V-1W

Bath Controller White (limited quantity)

$145

MC-100V-1S

Controller Silver

$128

MC-100V-1W

Controller White (limited quantity)

$128

RWM101

Control-R™ Wi-Fi Module

$125

MC-195T-US

Recirculation Timer & Temperature Controller

$170

Demand Recirculation Accessories

GTK15

Pump with Timer For Circ-Logic (SE+, HE+)

$320

RWMPB01*

Control-R™ Wi-Fi Push Button (1PB)

$50

RWMMS01

Control-R™ Wi-Fi Motion Sensor (1MS)

$200

Demand Recirculation Kits for SE+ Series featuring ThermaCirc360™ RWMKT01

Control-R™ Wireless Demand Recirculation Kit (Module, 1PB)

$175

RWMKT03

Control-R™ Wireless Demand Recirculation (Module, 1PB, 1MS)

$400

Demand Recirculation Kits for HE+ and SE+ Series featuring Circ-Logic RWMKT01P

Control-R™ Wireless Demand Recirculation (Pump Kit, 1PB)

$525

RWMKT03P

Control-R™ Wireless Demand Recirculation (Pump Kit, 1PB, 1TS)

$750

MIVK-T-LW

Isolation Valve Kit (excludes SENSEI™)

$109

107000284

Isolation Valve Kit (SENSEI™)

$109

REU-PVA-4

Pressure Valve Activating (Legacy SE+, RUC)

$77

Other Accessories

NEW

NEW

• •

804000074

Condensate Neutralizer Kit

$85

809000114

Condensate Neutralizer Refill

$30

103000038

ScaleCutter System

$210

103000039

ScaleCutter Refill Cartridge

$110

104000059

Freeze Protection, Drain Down Kit (SE, HE, HE+)

$400

104000285

Freeze Protection, Drain Down Kit (SENSEI™)

$600

Stand alone venting / accessory orders require a $2,000 minimum to qualify for (FFA) Full Freight Allowed. FOB Rinnai Georgia, Nevada, Pennsylvania. SENSEI™ Isolation Valve

2018 SUGGESTED LIST PRICE (USD) • Page 13 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Accessories for Tankless Water Heaters (Cont’d) Connection Cables NEW

REU-EZC-2*

EZConnect™ (2 Units) (SE+/SE/HE+/HE)

$45

REU-EZC-1-US

EZConnect™ Accessory Cable (2 Units) (SE/HE+/HE)

$22

REU-MSB-M

Multi-Unit Control Kit (+2 Units) (MSB + Multi-Unit Cable) (SE/HE+/HE)

$150

REU-MSB-C2

MSB Cable (+2 Units) (SE/HE+/HE)

$65

REU-MSB-C1

Multi-unit Cable (+2 Units) (SE/HE+/HE)

$46

NEW

REU-OPU3

BMS/Air Handler (Replaces 103000037) (SE+/SE/HE+/HE)

$30

103000037

Domestic Priority Switch for Hydronic Air Handler (SE/HE+/HE)

$30

REU-CSA-C1

Cascade harness 3m (Commercial)

$35

REU-CSA-C2

Cascade harness 8m (Commercial)

$65

PCD07-SM

Pipe Cover for SE+

$128

PCD07-EW

Pipe Cover for SE (Euro White)

$128

Pipe Enclosures

PCD03-SM2

Pipe Cover for HE+

$128

NEW

PCD03-EWV

Pipe Cover for HE (excludes V53De)

$128

NEW

PCD01-EWV

Pipe Cover for V53De (Euro White)

$116

PC-20-W

Pipe Cover for V53e (Euro White)

$116

PCD07-IB

Pipe Cover for Commercial (Indigo Black)

$128

PCD07-SM-BP

Bottom Plate for SE+

$36

PCD07-EW-BP

Bottom Plate for SE (Euro White)

$36

PCD03-SM2-BP

Bottom Plate for HE+/HE/V53

$36

PCD07-IB-BP

Bottom Plate for Commercial (Indigo Black)

$50

RGB-CTWH-4

Recess Box for Condensing Tankless (SENSEI™ SE+, SE Series, Commercial)

$405

RGB-CTWH-3

Recess Box for Condensing SE Series (RUCS and RUS Models)

$405

RGB-25U-C

Recess Box for HE, HE+ Series (excludes V53e Models)

$159

Recess Boxes

RGB-20-U

Recess Box for V53e/V53De

$252

RGB-CTWH-2

Recess Box for Legacy Condensing Models (KB and KBP Generation)

$405

RGB-25U-MSAL-C

Universal Moisture Seal Recess Box for HE, HE+ Series (excludes V53e Models)

$340

109000724

Replacement Door Kit (SENSEI™ SE+)

$0

109000535

Replacement Door Kit for SE

$0

109000824

Replacement Door Kit for V53De

$0

109000284

Replacement Door Kit (Legacy Condensing Models)

$0

109000283

RGB-25U/MSAL Replacement Door Kit (for fitting VC units into old RGB-25U/MSAL boxes)

$0

104000050

RGB-25W Replacement Door Kit (for fitting R94/75LSe units into RGB-25W/MS recess boxes)

$0

104000055

RGB-25MSW Replacement Door Kit (for fitting R94/R75LSe units into RGB-25MSW recess boxes)

$0

NOTES: • Accessory cable used for Freeze Protection, BMS and Air Handler

2018 SUGGESTED LIST PRICE (USD) • Page 14 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Accessories for Tankless Water Heaters (Cont’d) Conversion Kits (LP to NG or NG to LP) (Includes 2 Data Plates: 2 Orifices) 103000076

Conversion Kit - RUR199i, RU199i, CU199i

$28

103000077

Conversion Kit - RUR199e, RU199e, CU199e

$28

103000078

Conversion Kit - RU180i

$28

103000079

Conversion Kit - RU180e

$28

103000080

Conversion Kit - RU160i, RUR160i, CU160i

$28

103000081

Conversion Kit - RU160e, RUR160e, CU160e

$28

103000082

Conversion Kit - RU130i

$28

103000083

Conversion Kit - RU130e

$28

2018 SUGGESTED LIST PRICE (USD) • Page 15 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER

• • • • •

Installation Type

Internal (Indoor) Residential Applications. Manufactured (Mobile) Home Certified

Model Numbers

RU199i (REU-N3237FF-US) RU180i (REU-N2934FF-US) RU160i (REU-N2530FF-US) RU130i (REU-N2024FF-US)

Approved Gas Types

Natural and Propane

Uniform Energy Factor (UEF)

RU199i, RU180i, RU160i: RU130i:

0.93 0.91

Energy Factor (EF) (Canada)

RU199i: RU180i, RU160i, RU130i:

0.96 0.95

High Altitude Approved

Up to 10,200 ft (3,109 m)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Bypass Control

Controller

Standard: Integrated Controller Optional: MC-195T-US, MC-100V-1US, BC-100V-1US, MCC-91-2US

Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe)

Certifications

Non-Direct Vent (Room Air)

AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®

Common Vent (Direct Vent and Room Air)

Warranty

Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes 2 in. (51 mm) 3 in. (76 mm)

• Heat Exchanger: 15 years or 12,000 operation hours, whichever

Vent Lengths

65 ft (20 m)

occurs first

• All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year

150 ft (46 m)

Safety Devices

Concentric Vent Sizes

2 in. X 4 in.

3 in. X 5 in.

Vent Lengths

65 ft (20 m)

150 ft (46 m)

Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase

• • • •

Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2) and Self-Tapping Screws (x2)

Compact Design to Save Space

Additional Features

Wi-Fi Technology for Remote Monitoring and Management

• Mobile Home Certified • Ultra Low NOx • Complies with South Coast • Tankless Rack System™ Compatible Air Quality Management • 1/2 in. (13 mm) Gas Line Compatible

Sliding Mounting Bracket for Easy Installation Simple Gas Conversion

District 14 ng/J or 20 ppm NOx Emission Levels

Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


in. (mm)

Electrical

SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level

RU199i RU180i RU160i RU130i 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm)

FRONT

15,000 199,000

180,000

160,000

130,000

0.26 - 9.8 GPM 0.26 - 9.0 GPM 0.26 - 8.0 GPM 0.26 - 6.6 GPM (1.0 - 37 L/min) (1.0 - 34 L/min) (1.0 - 30 L/min) (1.0 - 24 L/min) 11 GPM 10 GPM 9 GPM 7 GPM (42 L/min) (38 L/min) (34 L/min) (26 L/min) 64 lb (29 kg) 64 lb (29 kg) 62 lb (28 kg) 62 lb (28 kg) 48 dB 47 dB 47 dB 47 dB

Normal Standby

84 W

65 W

52 W

38 W

1.3 W

Freeze Protection Max Current

148 W 4 Amps

Fuse

10 Amps

• Minimum: 98° F (37° C) Default • Maximum: 120° F (49° C) Default

Temperature

SIDE

140° F (60° C) With Parameter Adjustment

By-Pass Flow Control

Electronic

Vent Connection:

Gas Supply Pressure

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

nominal PVC/

• • • •

Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)

Polypropylene or

• • • • • • •

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT

2

Electronic Connections

2 in. (51 mm)

3 in./5 in.

Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)

Water Supply Pressure Controller Cable Service Connections

Clearances

Concentric.

• Back: 0 in. • Sides: 2 in. (51 mm)*** • Vent: 0 in.

Top: 2 in. (51 mm)* Bottom/Ground: 12 in. (305 mm) Front: 0 in.**

* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box

BOTTOM

1

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.

Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.

Connection COLD HOT GAS 0

25

50

75

100

125

150

PRV

F C H B E D G A

in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193


SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type

External (Outdoor) Residential Applications. Manufactured (Mobile) Home Certified

Model Numbers

RU199e (REU-N3237W-US) RU180e (REU-N2934W-US) RU160e (REU-N2530W-US) RU130e (REU-N2024W-US)

Approved Gas Types

Natural and Propane

Uniform Energy Factor (UEF)

RU199e, RU180e, RU160e: RU130e:

0.93 0.92

Energy Factor (EF) (Canada)

RU199e, RU180e, RU160e: RU130e:

0.96 0.95

High Altitude Approved

Up to 10,200 ft (3,109 m)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Bypass Control

Controller

Standard: Integrated Controller Optional: MC-195T-US, MC-100V-1US, BC-100V-1US, MCC-91-2US

Certifications

AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®

Warranty

• Heat Exchanger: 15 years or 12,000 operation hours, whichever • Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion

occurs first

• All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase

Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

• • • •

Tankless Water Heater Pressure Relief Valve and Adapter Isolation Valve Kit Integrated Controller

Additional Features

• Mobile Home Certified • Ultra Low NOx • Complies with South Coast • Tankless Rack System™ Compatible Air Quality Management District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line NOx Emission Levels

Compatible

● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


in. (mm)

Electrical

SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level

FRONT

RU199e RU180e RU160e RU130e 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000 199,000

180,000

160,000

0.26 - 9.8 GPM 0.26 - 9.0 GPM 0.26 - 8.0 GPM (1.0 - 37 L/min) (1.0 - 34 L/min) (1.0 - 30 L/min) 11 GPM 10 GPM 9 GPM (42 L/min) (38 L/min) (34 L/min) 64 lb (29 kg) 64 lb (29 kg) 62 lb (28 kg) 53 dB 52 dB 52 dB

Normal Standby

81 W

62 W

130,000 0.26 - 6.6 GPM (1.0 - 24 L/min) 7 GPM (26 L/min) 62 lb (28 kg) 52 dB

49 W

36 W

1.3 W

Freeze Protection Max Current

152 W 4 Amps

Fuse

10 Amps

• Minimum: 98° F (37° C) Default • Maximum: 120° F (49° C) Default

Temperature

140° F (60° C) With Parameter Adjustment

By-Pass Flow Control

Electronic

Gas Supply Pressure

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

2

Electronic Connections Water Supply Pressure Controller Cable Service Connections

Clearances

SIDE

• • • •

Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)

• • • • • • •

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT

Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)

Top: 2 in. (51 mm)* • Back: 0 in. Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** Front: 0 in.** • Front Exhaust: 24 in. (610 mm)

* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box

BOTTOM

1

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.

Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.

Connection COLD HOT GAS PRV 0

25

50

75

100

125

150

F C H B E D G A

in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193


SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type Model Numbers Approved Gas Types Uniform Energy Factor (UEF) Energy Factor (EF) (Canada) High Altitude Approved Water Flow Control Controller Certifications

• • • • •

Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year

Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Maximum Equivalent Vent Lengths: Twin Pipe:

Concentric:

Vent Sizes

Internal (Indoor) Residential Applications. Manufactured (Mobile) Home Certified RUR199i (REU-NP3237FF-US) RUR160i (REU-NP2530FF-US) Natural and Propane 0.93 RUR199i: 0.96 RUR160i: 0.95 Up to 10,200 ft (3,109 m) Water Flow Sensor, Electronic Water Control and Bypass Control Standard: MC-91-2US Required for Recirculation: MC-195T-US or Control-R™ Wi-Fi Module AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®

2 in. (51 mm)

3 in. (76 mm)

Vent Lengths

65 ft (20 m)

150 ft (46 m)

Vent Sizes

2 in. X 4 in.

3 in. X 5 in.

Vent Lengths

65 ft (20 m)

150 ft (46 m)

Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Thermal Bypass Valve, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2) and Self-Tapping Screws (x2)

Rinnai Circ-Logic recirculation technology allows users to set recirculation patterns that coincide with their hot water usage patterns. Hot water is available when needed, without the expense of circulating it during times of inactivity. Two recirculation modes are available: • Dedicated Mode - With a dedicated return line, the integrated pump recirculates water from the tankless water heater through the return line and back to the heater. • Crossover Mode - In applications where a dedicated return line is not available or is difficult to install, ThermaCirc360® technology allows for the simple installation of a Thermal Bypass Valve (included with purchase) at the fixture farthest away from the water heater.

Additional Features • Mobile Home Certified • Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels

• Ultra Low NOx • Tankless Rack System™ Compatible • 1/2 in. (13 mm) Gas Line Compatible

Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

Thermal Bypass Valve

• • • •

Compact Design to Save Space Wi-Fi Technology for Remote Monitoring and Management Sliding Mounting Bracket for Easy Installation Simple Gas Conversion

● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


in. (mm)

Electrical

SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level

FRONT

RUR199i RUR160i 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000 199,000

160,000

0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 73 lb (33 kg) 49 dB

0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 71 lb (32 kg) 48 dB

Normal Standby

84 W

52 W 1.3 W

Freeze Protection Max Current

160 W 4 Amps

Fuse

10 Amps

• Minimum:

98° F (37° C) Default 120° F (49° C) Crossover Mode • Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment Electronic

Temperature By-Pass Flow Control

SIDE Vent Connection:

Gas Supply Pressure

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

nominal PVC/

• Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital) • Minimum: 50 PSI (Recommended 60-80 PSI for max

Polypropylene or

2

Electronic Connections Water Supply Pressure

2 in. (51 mm)

3 in./5 in. Concentric.

performance) • Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)

Controller Cable

• • • • • • •

Service Connections

Clearances

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT Top: 2 in. (51 mm)* • Back: 0 in. Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** Front: 0 in.** • Vent: 0 in.

* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box 1 2

BOTTOM

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). The maximum gas supply pressure must not exceed the value specified by the manufacturer.

Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.

Connection COLD HOT GAS 0

25

50

75

100

125

150

PRV

F C H B E D G A

in. mm 9.27 235 3.11 79 14.49 368 6.52 166 3.57 91 2.79 71 10.40 264 7.60 193


35 Pump Performance Curve

30

Pump and Tankless Performance Curve @140°F Set

20 15

(5.30 GPM)

10 (1.05 GPM)

Head - Feet

25

5

0 0

1

2

3 Flow Rate (GPM)

4

5

The RUR pump has an operation range of 1.05 GPM to 5.30 GPM

Internal Recirculation Pump Control

Built-in Rinnai Circ-Logic: Recirculation program cycles internal pump

Internal Pump

Integrated pump and bypass technology allow for recirculation through a dedicated return line or thermal bypass valve.

Maximum Recirculation Pipe Lengths

• •

400 equivalent feet for 3/4 in. pipe diameter 100 equivalent feet for 1/2 in. pipe diameter Take equivalent elbow lengths into consideration when calculating pipe length. For dedicated return lines: Total length includes both hot water supply and dedicated return lines. Cross-over mode: Total length includes both hot water supply and cold water piping length from the tankless water heater to the thermal bypass valve. Cross-over mode requires the use of a thermal bypass valve (included).

6


SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER

Rinnai Circ-Logic recirculation technology allows users to set recirculation patterns that coincide with their hot water usage patterns. Hot water is available when needed, without the expense of circulating it during times of inactivity. Two recirculation modes are available: • Dedicated Mode - With a dedicated return line, the integrated pump recirculates water from the tankless water heater through the return line and back to the heater. • Crossover Mode - In applications where a dedicated return line is not available or is difficult to install, ThermaCirc360® technology allows for the simple installation of a Thermal Bypass Valve (included with purchase) at the fixture farthest away from the water heater. Thermal Bypass Valve

Installation Type

External (Outdoor) Residential Applications

Model Numbers

RUR199e (REU-NP3237W-US) RUR160e (REU-NP2530W-US)

Approved Gas Types

Natural and Propane

Uniform Energy Factor (UEF)

0.93

Energy Factor (EF) (Canada)

0.96

High Altitude Approved

Up to 10,200 ft (3,109 m)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Bypass Control

Controller

Standard: MC-91-2US Required for Recirculation: MC-195T-US or Control-R™ Wi-Fi Module

Certifications

AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®

Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Thermal Bypass Valve, Pressure Relief Valve and Adapter, Isolation Valve Kit, Integrated Controller, and Recirculation Pump Cable Additional Features

• Complies with South Coast • Ultra Low NOx Air Quality Management • Tankless Rack System™ Compatible District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels

Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

• Compact Design to Save Space • Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


in. (mm)

Electrical

SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level

FRONT

RUR199e RUR160e 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000 199,000

160,000

0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 73 lb (33 kg) 53 dB

0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 71 lb (32 kg) 52 dB

81 W

49 W

Normal Standby Freeze Protection Max Current

1.3 W 198 W 4 Amps

Fuse

10 Amps

• Minimum: Temperature By-Pass Flow Control

98° F (37° C) Default 120° F (49° C) Crossover Mode • Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment Electronic

Gas Supply Pressure2

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

Electronic Connections Water Supply Pressure Controller Cable Service Connections

Clearances

SIDE

• • • •

Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)

• • • • • • •

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT Top: 2 in. (51 mm)* • Back: 0 in. Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** Front: 0 in.** • Front Exhaust: 24 in. (610 mm)

Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)

* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box 1 2

BOTTOM

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). The maximum gas supply pressure must not exceed the value specified by the manufacturer.

Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.

Connection COLD HOT GAS 0

25

50

75

100

125

150

PRV

F C H B E D G A

in. mm 9.27 235 3.11 79 14.49 368 6.52 166 3.57 91 2.79 71 10.40 264 7.60 193


35 Pump Performance Curve

30

Pump and Tankless Performance Curve @140°F Set

20 15

(5.30 GPM)

10 (1.05 GPM)

Head - Feet

25

5

0 0

1

2

3 Flow Rate (GPM)

4

5

The RUR pump has an operation range of 1.05 GPM to 5.30 GPM

Internal Recirculation Pump Control

Built-in Rinnai Circ-Logic: Recirculation program cycles internal pump

Internal Pump

Integrated pump and bypass technology allow for recirculation through a dedicated return line or thermal bypass valve.

Maximum Recirculation Pipe Lengths

• •

400 equivalent feet for 3/4 in. pipe diameter 100 equivalent feet for 1/2 in. pipe diameter Take equivalent elbow lengths into consideration when calculating pipe length. For dedicated return lines: Total length includes both hot water supply and dedicated return lines. Cross-over mode: Total length includes both hot water supply and cold water piping length from the tankless water heater to the thermal bypass valve. Cross-over mode requires the use of a thermal bypass valve (included).

6


RL75i (VC2528FFUD-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion / Direct vent

Rinnai Model Number

REU-VC2528FFUD-US

Operation / Installation

Forced combustion; indoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 180,000 BTU/h

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 76 w

Amperage

Max with pump: 8A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)

Temperature

98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with MCC-91-2 controller for hydronic applications

Temperature (without remote)

120° F (49° C) (factory default) or 140° F (60° C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT

Isolation & Pressure Relief Valves Included

Isolation Valves are certified to NSF/ANSI 61 for potable water

Water Flow Control

Water flow sensor, electronic water control device and fixed by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w

Anti-frost protection: 120 w

Max without pump: 4A

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Water Flow gpm (l/min)

Hot Water Flow Rate (gpm)

8.0 (30.3) 8.0

FLOW TABLE

7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0

00

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

125(69.4)

100

150(83.3)

125

150

RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature

© 2017 Rinnai Corporation

RL75i VC SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

SANITATION

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


RL75i (VC2528FFUD-US) External Recirculation Pump Control

Rinnai Circ-Logic™: Recirculation program cycles external pump

Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

 Top of heater - 6 inches(152mm)  Back of heater - 0 inches  Front of heater - 6 inches(152mm)*  Ground / bottom - 12 inches(305mm)  Sides of heater - 2 inches(51mm)  From vent pipe - 0 inches

Clearances from Non-combustibles

 Top of heater - 2 inches(51mm)  Back of heater - 0 inches  Front of heater - 6 inches(152mm)*  Ground / bottom - 12 inches(305mm) Sides of heater - 1/2 inch(13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure (sea level)

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.2” W.C. (5.5mbar) low fire 0.61” W.C. (1.5mbar) Propane Gas: high fire 3.8” W.C. (9.5mbar) low fire 0.87” W.C. (2.2mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Limited Warranty

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS 14.04 (356.6)

WEIGHT: 45.6 lb (20.7 kg) 9.27 (235.5)

0.4~1.8 (10~45) Variable 2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D DIMENSION Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

A

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


RL75e (VC2528WD-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion

Rinnai Model Number

REU-VC2528WD-US

Operation / Installation

Forced combustion; outdoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 180,000 BTU/h

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 57 w

Amperage

Max with pump: 8A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)

Temperature

98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with the MCC-91-2 controller for commercial and hydronic applications

Temperature (without remote)

120° F (49° C) (factory default) or 140° F (60° C)

Installation

Outdoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT

Isolation & Pressure Relief Valves Included

Isolation Valves are certified to NSF/ANSI 61 for potable water

Water Flow Control

Water flow sensor, electronic water control device and fixed by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w

Anti-frost protection: 104 w

Max without pump: 4A

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Water Flow gpm (l/min)

Hot Water Flow Rate (gpm)

8.0 (30.3) 8.0

FLOW TABLE

7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0

00

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

125(69.4)

100

150(83.3)

125

150

RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature

© 2017 Rinnai Corporation

RL75e VC SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

SANITATION

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


RL75e (VC2528WD-US) External Recirculation Pump Control

Rinnai Circ-Logic™: Recirculation program cycles external pump

Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 12 inches(305mm)  Back of heater - 0 inches  Bottom of heater - 12 inches(305mm)  Front (Panel) - 24 inches(610mm)  Front (Exhaust) - 24 inches(610mm)  Sides of heater - 6 inches(152mm)

Clearances from Non-combustibles

 Back of heater - 0 inches  Top of heater - 2 inches(51mm)  Bottom of heater - 2 inches(51mm)  Front (Panel) - 0 inches *  Front (Exhaust) - 24 inches(610mm)  Sides of heater - 1/8 inch(3.2mm)

*24 inches required for serviceability

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.) (sea level)

Natural Gas: high fire 2.0” W.C. (5.0mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 3.5” W.C. (8.7mbar) low fire 0.80” W.C. (2.00mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS 14.04 (356.6)

WEIGHT: 43.6 lb (19.8 kg) 2.23 (56.6)

Limited Warranty

0.28 (7.2)

9.27 (235.5)

0.59 (15)

8.90 (226)

C

F G

E D

22.95 (583)

1.14 (29)

B

DIMENSION Inches (mm)

A

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.91 (73.8)

A (HOT)

1.35 (34.4)

F

1.61 (40.8)

B

3.96 (100.7)

G

2.87 (73)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


RL94i (VC2837FFUD-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion / Direct vent

Rinnai Model Number

REU-VC2837FFUD-US

Operation / Installation

Forced combustion; indoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 199,000 BTU/h

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 97 w

Amperage

Max with pump: 8A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)

Temperature

98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications

Temperature (without remote)

120°F (49°C) (factory default) or 140°F (60°C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT

Isolation & Pressure Relief Valves Included

Isolation Valves are certified to NSF/ANSI 61 for potable water

Water Flow Control

Water flow sensor, electronic water control device and by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w

Anti-frost protection: 120 w

Max without pump: 4A

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE

10.0 (37.9) 10.0

Water Flow gpm (l/min)

9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0

0

0

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

100

125(69.4)

125

150(83.3)

150

delta T - Temperature Rise (ºF) © 2017 Rinnai

RL94i VC SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


RL94i (VC2837FFUD-US) External Recirculation Pump Control

Rinnai Circ-Logic™(Included): Recirculation program cycles external pump

Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

 Top of heater - 6 inches (152mm)  Back of heater - 0 inches  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 2 inches (51mm)  From vent pipe - 0 inches

Clearances from Non-combustibles

 Top of heater - 2 inches (51mm)  Back of heater - 0 inches  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 1/2 inch (13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure (sea level)

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.9” W.C. (7.22mbar) low fire 0.61” W.C. (1.52mbar) Propane Gas: high fire 4.7” W.C. (11.71mbar) low fire 0.87” W.C. (2.17mbar)

NOx

Complies with South Coast Air Quality Management District 40 ng/J or 55 ppm NOx emission levels

Limited Warranty

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS 14.04 (356.6)

WEIGHT: 46.3 lb (21.0 kg) 9.27 (235.5)

0.4~1.8 (10~45) Variable 2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D

A

DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


RLX94i (VC2737FFUD-US) Nat. Gas Unit Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion / Direct vent

Rinnai Model Number

REU-VC2737FFUD-US

Minimum/Maximum Gas Rate (Input)

10,300 - 192,000 BTU/h (3.02-56.3kWh)

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 97 w

Amperage

Max with pump: 8A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)

Temperature

98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications

Temperature (without remote)

120°F (49°C) (factory default) or 140°F (60°C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT

Isolation & Pressure Relief Valves Included

Isolation Valves are certified to NSF/ANSI 61 for potable water

Water Flow Control

Water flow sensor, electronic water control device and by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w

Anti-frost protection: 120 w

Max without pump: 4A

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Water Flow gpm (l/min)

FLOW TABLE

(37.9) 10.0 10.0 (34.1) 9.09.0 (30.3) 8.08.0 (26.5) 7.07.0 (22.7) 6.06.0 (19.0) 5.05.0 (15.1) 4.04.0 (11.4) 3.03.0 (7.6) 2.02.0 (3.8) 1.01.0

0.0 0.0

0

25

50

(13.9)

(27.8)

25

50

75 75

(41.6)

100 100 (55.6)

150

125 125 (69.4)

150 (83.3)

delta T - Temperature Rise ºF (ºC)

© 2017 Rinnai Corporation

RLX94i VC SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


RLX94i (VC2737FFUD-US) Nat. Gas Unit External Recirculation Pump Control Water Temperature Control

Rinnai Circ-Logic™(Included): Recirculation program cycles external pump

Simulation feed forward and feedback

Controller

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

 Top of heater - 6 inches (152mm)  Back of heater - 0 inches  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 2 inches (51mm)  From vent pipe - 0 inches

Clearances from Non-combustibles

 Back of heater - 0 inches  Top of heater - 2 inches (51mm)  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 1/2 inch (13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure (sea level)

Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.93” W.C. (7.3mbar) Low fire 0.61” W.C. (1.5mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Limited Warranty

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS 14.04 (356.6)

WEIGHT: 46.3 lb (21.0 kg) 9.27 (235.5)

0.4~1.8 (10~45) Variable 2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D DIMENSION Inches (mm)

A

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


RL94e (VC2837WD-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion

Rinnai Model Number

REU-VC2837WD-US

Operation / Installation

Forced combustion; outdoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 199,000 BTU/h

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 65 w

Amperage

Max with pump: 8A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)

Temperature

98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications

Temperature (without remote)

120°F (49°C) (factory default) or 140°F (60°C)

Installation

Outdoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT

Isolation & Pressure Relief Valves Included

Isolation Valves are certified to NSF/ANSI 61 for potable water

Water Flow Control

Water flow sensor, electronic water control device and by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Standby: 2 w

Anti-frost protection: 104 w

Max without pump: 4A

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE

10.0 (37.9) 10.0

Water Flow gpm (l/min)

9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0

0

0

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

100

125(69.4)

125

150(83.3)

150

delta T - Temperature Rise (ºF) © 2017 Rinnai Corporation

RL94e VC SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


RL94e (VC2837WD-US) External Recirculation Pump Control

Rinnai Circ-Logic™(Included): Recirculation program cycles external pump

Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 12 inches(305mm)  Back of heater - 0 inches  Bottom of heater - 12 inches(305mm)  Front (Panel) - 24 inches(610mm)  Front (Exhaust) - 24 inches(610mm)  Sides of heater - 6 inches(152mm)

Clearances from Non-combustibles

 Top of heater - 2 inches(51mm)  Front (Panel) - 0 inches * Front (Exhaust) - 24 inches(610mm)

* 24 inches required for serviceability

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

 Back of heater - 0 inches  Bottom of heater - 2 inches(51mm)  Sides of heater - 1/8 inch(3.2mm)

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.) (sea level)

Natural Gas: high fire 2.5” W.C. (6.23mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 4.5” W.C. (11.21mbar) low fire 0.80” W.C. (2.00mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for commercial; All other parts: 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS 14.04 (356.6)

WEIGHT: 44.3 lb (20.1 kg) 2.23 (56.6)

Limited Warranty

0.28 (7.2)

9.27 (235.5)

0.59 (15)

8.90 (226)

C

F G

E D

22.95 (583)

1.14 (29)

B

A

DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.91 (73.8)

A (HOT)

1.35 (34.4)

F

1.61 (40.8)

B

3.96 (100.7)

G

2.87 (73)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


HIGH-EFFICIENCY (NON-CONDENSING) TANKLESS WATER HEATER Installation Type

External (Outdoor) Residential Applications. Manufactured (Mobile) Home Certified

Model Number

V53De (REU-AM1620WD-US)

Approved Gas Types

Natural and Propane

Water Flow Control

Water Flow Sensor, Electronic Water Control and Fixed Bypass

Water Temperature Control Simulation Feed Forward and Feedback Ignition System

Direct Electronic Ignition

Controller

Standard: Status Monitor Optional: MC-601, MC-91-2US Certifications AHRI, ANSI Z21.10.3, CSA 4.3 Uniform Energy Factor (UEF) 0.81 High Altitude Approved

Up to 10,200 Ft (3,109 M)

Minimum Gas Consumption 15,500 Btu/h Maximum Gas Consumption 120,000 Btu/h

To Non-Combustibles in. (mm)

Top

12 (305)

2 (51)

Back

0 (zero)

0 (zero)

Front (Panel)

24 (610)

0 (zero)

Front (Exhaust)

24 (610)

24 (610)

Sides

6 (152)

1/8 (3.2)

Bottom

12 (305)

2 (51)

0.4 - 5.3 GPM (1.5 - 20.0 L/min)

Dimensions - w, h, d

14.0 in. x 19.8 in. x 7.9 in. (356 mm x 503 mm x 202 mm) 29.7 lb (13.5 kg)

Weight Sound Level Normal Standby Freeze Protection

Electrical

To Combustibles in. (mm)

Flow Rate1 (Min - Max)

50 W 2W 64 W

Max Current

1.2 Amps

Fuse

5 Amps

• Minimum: 115° F (46° C) Default • Maximum: 140° F (60° C) Default

Temperature

Without Temperature Controller: 120° F (49° C) Default or 140° F (60° C) Bypass Flow Control

The clearance for servicing is 24 in. (610 mm) in front of the water heater.

Gas Supply Pressure

Fixed 2

Electronic Connections

54 dB

• • • •

Natural: 4.5 in. w.c. - 10.5 in. w.c. Propane: 8.0 in. w.c. - 13.5 in. w.c. Appliance: AC 120 Volts, 60Hz. Temp. Controller: DC 12 Volts (Digital)

• Minimum: 20 PSI (Recommended

Safety Devices: Flame Failure -Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current-Glass Fuse, Remaining Flame (OHS), Automatic Frost Protection, and Thermal Fuse

Water Supply Pressure

• •

Gas Line Compatible: 1/2 in. (13 mm)

Controller Cable

Complies with South Coast Air Quality Management District 40 ng/J NOx Emission Levels

Non-Polarized Two Core Cable (Minimum 22 AWG)

Service Connections

Included with Purchase: V53De Tankless Water Heater and Wall Mounting Bracket

• Gas Supply: 3/4 in. (19 mm) MNPT • Cold Water Inlet: 3/4 in. (19 mm) MNPT • Hot Water Outlet: 3/4 in. (19 mm) MNPT

30-80 PSI for max performance)

• Maximum: 150 PSI

1

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.6 GPM (1.5 L/min).

2

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


in. (mm) A

Width

14.0 (356)

B

Depth

7.9 (202)

C

Height (Unit)

19.8 (503)

D

Height (With Brackets)

22.5 (571)

E

Hot Water Outlet From Wall

3.4 (87)

F

Hot Water Outlet From Center

4.1 (105)

G

Cold Water Inlet From wall

2.7 (68)

H

Cold Water Inlet From Center

0.4 (10)

I

Gas Connection From wall

3.0 (77)

J

Gas Connection From Center

3.3 (83)

K

From Base to Gas Connection

1.6 (40)

From Base to Cold Connection

2.0 (50)

From Base to Hot Connection

1.5 (39)

6.0

Water Flow (GPM)

5.0

4.0

3.0

2.0

1.0

0.0

0

25

50

75

100

Delta T - Temperature Rise (°F)

125

150


V65i (VC2025FFU-US) Type of Appliance

• • •

Rinnai Model Number

REU-VC2025FFU-US

Operation/Installation

Forced combustion; indoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 150,000 BTU/h (3.0-44.0 kWh)

Electrical

• •

Electrical Consumption

Normal: 76 w

Standby: 2 w

Amperage

Max: 4A

Fuse: 10A

Ignition System

Direct Electronic Ignition

Hot Water Capacity

• • •

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)

Temperature

• • •

98°-120° F (37°- 49° C) (factory default) Maximum temperature is selectable at 120° F (49° C) or at 140° F (60° C) 98°-160° F (37°-71° C) available with the MCC-91-2 controller for hydronic applications

Temperature (without remote)

120° F (49° C) (factory default) or 140° F (60° C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.80

Service Connections

• • •

Water Flow Control

Water flow sensor, electronic water control device and fixed bypass

Minimum/Maximum Water Supply Pressure

• •

Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced Combustion / Direct Vent

Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Anti-frost protection: 120 w

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT 20-150 PSI (138-1,035 KPa) Recommend 30-80 PSI (209-552 KPa) for optimal performance

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE

Water Flow gpm (l/min)

7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0 0 0

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

125(69.4)

100

125

150(83.3)

150

delta T - Temperature Rise (ºF) © 2018 Rinnai

V65i SP(03)

6/2018 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


V65i (VC2025FFU-US) Water Temperature Control

Simulation feed forward and feedback

Controller

• • • •

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

• • • •

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

• • •

• Top of heater - 6 inches (152 mm) Front of heater - 6 inches (152 mm)* • Sides of heater - 2 inches (51 mm) •

Back of heater - 0 inches Ground / bottom - 12 inches (305 mm) From vent pipe - 0 inches

Clearances from Non-combustibles

• Top of heater - 2 inches (51 mm) • • Front of heater - 6 inches (152 mm)* • • Sides of heater - 1/2 inch (13 mm) • * 24 inches required for serviceability

Back of heater - 0 inches Ground / bottom - 12 inches (305 mm) From vent pipe - 0 inches

Min/Max Gas Supply Pressure

• •

Natural Gas: Min: 4” W.C. (10 mbar) Propane Gas: Min: 8” W.C. (20 mbar)

Max: 10.5” W.C. (26.1 mbar) Max: 13.5” W.C. (33.6 mbar)

Manifold Gas Pressure (inches W.C.)

• •

Natural Gas: High Fire: 1.8” W.C. (4.5 mbar) Propane Gas: High Fire: 2.8” W.C. (7.0 mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Warranty

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)

• • •

Remaining flame (OHS) Thermal fuse Automatic frost protection

Low Fire: 0.61” W.C. (1.5 mbar) Low Fire: 0.87” W.C. (2.2 mbar)

Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)

DIMENSIONS 14.04 (356.6)

WEIGHT: 45.6 lb (20.7 kg) 9.27 (235.5)

0.4~1.8(10~45) Variable

2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D

A

DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


V65e (VC2025W-US) Type of Appliance

• • •

Rinnai Model Number

REU-VC2025W-US

Operation/Installation

Forced combustion; outdoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 150,000 BTU/h (3.0-44.0 kWh)

Electrical

• •

Electrical Consumption

Normal: 57 w

Standby: 2 w

Amperage

Max: 4A

Fuse: 10A

Ignition System

Direct Electronic Ignition

Hot Water Capacity

• • •

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)

Temperature

• • •

98°-120° F (37°- 49° C) (factory default) Maximum temperature is selectable at 120° F (49° C) or at 140° F (60° C) 98°-160° F (37°-71° C) available with the MCC-91-2 controller for hydronic applications

Temperature (without remote)

120° F (49° C) (factory default) or 140° F (60° C)

Installation

Outdoor only

Uniform Energy Factor (UEF)

0.79

Service Connections

• • •

Water Flow Control

Water flow sensor, electronic water control device and fixed bypass

Minimum/Maximum Water Supply Pressure

• •

Temperature controlled, continuous flow, gas hot water system Certified for installation in manufactured (mobile) homes Forced combustion

Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Anti-frost protection: 104 w

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT 20-150 PSI (138-1,035 KPa) Recommend 30-80 PSI (209-552 KPa) for optimal performance

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. 7.0 (26.5) 7.0

Water Flow gpm (l/min)

FLOW TABLE

6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0 0 0

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

125(69.4)

100

125

150(83.3)

150

delta T - Temperature Rise (ºF) © 2018 Rinnai Corporation

V65e SP(03)

6/2018 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


V65e (VC2025W-US) Water Temperature Control

Simulation feed forward and feedback

Controller

• • • •

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

• • • •

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Clearances from Combustibles

• • •

Top of heater - 12 inches (305 mm) Front (Panel) - 24 inches (610 mm) Front (Exhaust) - 24 inches (610 mm)

• • •

Back of heater - 0 inches Bottom of heater - 12 inches (305 mm) Sides of heater - 6 inches (152 mm)

Clearances from Non-combustibles

• • •

Top of heater - 2 inches (51mm) Front (Panel) - 0 inches * Front (Exhaust) - 24 inches (610 mm)

• • •

Back of heater - 0 inches Bottom of heater - 2 inches (51 mm) Sides of heater - 1/8 inch (3.2 mm)

MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)

• • •

Remaining flame (OHS) Thermal fuse Automatic frost protection

* 24 inches required for serviceability Min/Max Gas Supply Pressure

• •

Natural Gas: Min: 4” W.C. (10 mbar) Propane Gas: Min: 8” W.C. (20 mbar)

Manifold Gas Pressure (inches W.C.)

• •

Natural Gas: High fire 1.30” W.C. (3.24 mbar) Propane Gas: High fire 2.45” W.C. (6.10 mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Low fire 0.52” W.C. (1.30 mbar) Low fire 0.80” W.C. (2.00 mbar)

Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year; (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater)

DIMENSIONS 14.04 (356.6)

WEIGHT: 43.6 lb (19.8 kg) 2.23 (56.6)

Warranty

Max: 10.5” W.C. (26.1 mbar) Max:13.5” W.C. (33.6 mbar)

0.28 (7.2)

9.27 (235.5)

0.59 (15)

8.90 (226)

C

F G

E D

22.95 (583)

1.14 (29)

B

DIMENSION Inches (mm)

A

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.91 (73.8)

A (HOT)

1.35 (34.4)

F

1.61 (40.8)

B

3.96 (100.7)

G

2.87 (73)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


V75i (VC2528FFU-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion / Direct vent

Rinnai Model Number

REU-VC2528FFU-US

Operation / Installation

Forced combustion; indoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 180,000 BTU/h

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 76 w

Standby: 2 w

Amperage

Max: 4A

Fuse: 10A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)

Temperature

98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with MCC-91-2 controller for hydronic applications

Temperature (without remote)

120° F (49° C) (factory default) or 140° F (60° C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT

Water Flow Control

Water flow sensor, electronic water control device and fixed by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Anti-frost protection: 120 w

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Water Flow gpm (l/min)

Hot Water Flow Rate (gpm)

8.0 (30.3) 8.0

FLOW TABLE

7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0

00

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

125(69.4)

100

125

150(83.3)

150

RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature

© 2017 Rinnai Corporation

V75i SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


V75i (VC2528FFU-US) Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

 Top of heater - 6 inches(152mm)  Back of heater - 0 inches  Front of heater - 6 inches(152mm)*  Ground / bottom - 12 inches(305mm)  Sides of heater - 2 inches(51mm)  From vent pipe - 0 inches

Clearances from Non-combustibles * 24 inches required for serviceability

 Top of heater - 2 inches(51mm)  Back of heater - 0 inches  Front of heater - 6 inches(152mm)*  Ground / bottom - 12 inches(305mm)  Sides of heater - 1/2 inch(13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.2” W.C. (5.5mbar) low fire 0.61” W.C. (1.5mbar) Propane Gas: high fire 3.8” W.C. (9.5mbar) low fire 0.87” W.C. (2.2mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Limited Warranty

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.

DIMENSIONS 14.04 (356.6)

WEIGHT: 45.6 lb (20.7 kg) 9.27 (235.5)

0.4~1.8 (10~45) Variable 2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

A

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us


V75e (VC2528W-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion

Rinnai Model Number

REU-VC2528W-US

Operation / Installation

Forced combustion; outdoor only;

Minimum/Maximum Gas Rate (Input)

10,300 - 180,000 BTU/h

Electrical

Appliance: Controller:

Electrical Consumption

Normal: 57 w

Standby: 2 w

Amperage

Max: 4A

Fuse: 10A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)

Temperature

98° - 120° F (37° - 49° C) (factory default) Maximum temperature is selectable at 120° F(49° C) or at 140° F(60° C); 98° - 160° F(37° 71° C) available with MCC-91-2 controller for hydronic applications

Temperature (without remote)

120° F (49° C) (factory default) or 140° F (60° C)

Installation

Outdoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT

Water Flow Control

Water flow sensor, electronic water control device and fixed by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa for optimal performance)

AC 120 Volts - 60 Hz DC 12 Volts Anti-frost protection: 104 w

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Water Flow gpm (l/min)

Hot Water Flow Rate (gpm)

8.0 (30.3) 8.0

FLOW TABLE

7.0 (26.5) 7.0 6.0 (22.7) 6.0 5.0 (19.0) 5.0 4.0 (15.1) 4.0 3.0 (11.4) 3.0 2.0 (7.6) 2.0 1.0 (3.8) 1.0 0.0 0.0

00

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

125(69.4)

100

125

150(83.3)

150

RiseRise (°F) (ºF) deltaDTT –- Temperature Temperature

© 2017 Rinnai Corporation

V75e SP(02)

5/2017 C

U

Low Lead Content NSF/ANSI 372

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

SANITATION


V75e (VC2528W-US) Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic applications)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 12 inches(305mm)  Front (Panel) - 24 inches(610mm)  Front (Exhaust) - 24 inches(610mm)

 Back of heater - 0 inches  Bottom of heater - 12 inches(305mm)  Sides of heater - 6 inches(152mm)

Clearances from Non-combustibles

 Top of heater - 2 inches(51mm)  Front (Panel) - 0 inches *  Front (Exhaust) - 24 inches(610mm)

 Back of heater - 0 inches  Bottom of heater - 2 inches(51mm)  Sides of heater - 1/8 inch(3.2mm)

* 24 inches required for serviceability Min. / Max. Gas Supply Pressure

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.0” W.C. (5.0mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 3.5” W.C. (8.7mbar) low fire 0.80” W.C. (2.00mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.

DIMENSIONS

WEIGHT: 43.6 lb (19.8 kg)

14.04 (356.6)

2.23 (56.6)

Limited Warranty

0.28 (7.2)

9.27 (235.5)

0.59 (15)

8.90 (226)

C

F G

E D

22.95 (583)

1.14 (29)

B

A

DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.91 (73.8)

A (HOT)

1.35 (34.4)

F

1.61 (40.8)

B

3.96 (100.7)

G

2.87 (73)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


V94i (VC2837FFU-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion / Direct vent

Rinnai Model Number

REU-VC2837FFU-US

Operation / Installation

Forced combustion; indoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 199,000 BTU/h (3.02-58.3kWh)

Electrical

Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts

Electrical Consumption

Normal: 97 w

Amperage

Max : 4A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)

Temperature

98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for hydronic applications

Temperature (without remote)

120°F (49°C) (factory default) or 140°F (60°C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control device and by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

Standby: 2 w

Anti-frost protection: 120 w

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE

10.0 (37.9) 10.0

Water Flow gpm (l/min)

9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8)

0.00.0

0

0

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

100

125(69.4)

125

150(83.3)

150

delta T - Temperature Rise (ºF) © 2017 Rinnai

V94i VC SP-01

5/2017 C

U

Low Lead Content NSF/ANSI 372

SANITATION


V94i (VC2837FFU-US) Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

 Top of heater - 6 inches (152mm)  Back of heater - 0 inches  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 2 inches (51mm)  From vent pipe - 0 inches

Clearances from Non-combustibles

 Top of heater - 2 inches (51mm)  Back of heater - 0 inches  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 1/2 inch (13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure (sea level)

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.9” W.C. (7.22mbar) low fire 0.61” W.C. (1.52mbar) Propane Gas: high fire 4.7” W.C. (11.71mbar) low fire 0.87” W.C. (2.17mbar)

NOx

Complies with South Coast Air Quality Management District 40 ng/J or 55 ppm NOx emission levels

Limited Warranty

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.

DIMENSIONS

WEIGHT: 46.3 lb (21.0 kg) 9.27 (235.5)

14.04 (356.6)

0.4~1.8 (10~45) Variable 2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D

A

DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


V94Xi (VC2737FFU-US) Nat. Gas Unit Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion / Direct vent

Rinnai Model Number

REU-VC2737FFU-US

Minimum/Maximum Gas Rate (Input)

10,300 - 192,000 BTU/h (3.02-56.3kWh)

Electrical

Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts

Electrical Consumption

Normal: 97 w

Amperage

Max : 4A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)

Temperature

98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for hydronic applications

Temperature (without remote)

120°F (49°C) (factory default) or 140°F (60°C)

Installation

Indoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control device and by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

Standby: 2 w

Anti-frost protection: 120 w

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

Water Flow gpm (l/min)

FLOW TABLE

(37.9) 10.0 10.0 (34.1) 9.09.0 (30.3) 8.08.0 (26.5) 7.07.0 (22.7) 6.06.0 (19.0) 5.05.0 (15.1) 4.04.0 (11.4) 3.03.0 (7.6) 2.02.0 (3.8) 1.01.0

0.0 0.0

0

25

50

(13.9)

(27.8)

25

50

75 75

(41.6)

100 100 (55.6)

150

125 125 (69.4)

150 (83.3)

delta T - Temperature Rise ºF (ºC)

© 2017 Rinnai Corporation

V94Xi VC SP-01

5/2017 C

U

Low Lead Content NSF/ANSI 372

SANITATION


V94Xi (VC2737FFU-US) Nat. Gas Unit Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles (suitable for closet, attic, and crawl space installations)

 Top of heater - 6 inches (152mm)  Back of heater - 0 inches  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 2 inches (51mm)  From vent pipe - 0 inches

Clearances from Non-combustibles

 Back of heater - 0 inches  Top of heater - 2 inches (51mm)  Front of heater - 6 inches (152mm)  Ground / bottom - 12 inches (305mm)  Sides of heater - 1/2 inch (13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure (sea level)

Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.93” W.C. (7.3mbar) Low fire 0.61” W.C. (1.5mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Limited Warranty

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information. WEIGHT: 46.3 lb (21.0 kg)

DIMENSIONS

9.27 (235.5)

14.04 (356.6)

0.4~1.8 (10~45) Variable 2.67 (67.8)

5.05 (128.1)

B

C

E

F G

22.95 (583)

D DIMENSION Inches (mm)

A

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.89 (73.3)

A (HOT)

1.35 (34.4)

F

1.85 (47)

B

4.21 (106.9)

G

3.44 (87.3)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


V94e (VC2837W-US) Type of Appliance

 Temperature controlled, continuous flow, gas hot water system  Certified for installation in manufactured (mobile) homes  Forced combustion

Rinnai Model Number

REU-VC2837W-US

Operation / Installation

Forced combustion; outdoor only

Minimum/Maximum Gas Rate (Input)

10,300 - 199,000 BTU/h (3.02-58.3kWh)

Electrical

Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts

Electrical Consumption

Normal: 65 w

Amperage

Max : 4A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5l /min) Maximum flow rate: 9.8 GPM (37.1 l/min)

Temperature

98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 120°F (49°C) or at 140°F (60°C) ; 98° - 185°F (37°- 85°C) available with the MCC-91-2 controller for hydronic applications

Temperature (without remote)

120°F (49°C) (factory default) or 140°F (60°C)

Installation

Outdoor only

Uniform Energy Factor (UEF)

0.81

Service Connections

Gas supply: 3/4 inch(19mm) MNPT, Cold water inlet: 3/4 inch(19mm) MNPT Hot water outlet: 3/4 inch(19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control device and by-pass

Minimum/Maximum Water Supply Pressure

20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance)

Standby: 2 w

Anti-frost protection: 104 w

Fuse: 10A

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE

10.0 (37.9) 10.0

Water Flow gpm (l/min)

9.0 9.0 (34.1) 8.0 8.0 (30.3) 7.0 7.0 (26.5) 6.0 6.0 (22.7) 5.0 5.0 (19.0) 4.0 4.0 (15.1) 3.0 3.0 (11.4) 2.02.0 (7.6) 1.01.0 (3.8) 0.0 0.0

0

0

25(13.9)

25

50(27.8)

50

75(41.6)

75

100(55.6)

100

125(69.4)

125

150(83.3)

150

delta T - Temperature Rise (ºF) © 2017 Rinnai Corporation

V94e VC SP-01

5/2017 C

U

Low Lead Content NSF/ANSI 372

SANITATION


V94e (VC2837W-US) Water Temperature Control

Simulation feed forward and feedback

Controller

MC-91-2US (included) Deluxe controller: MC-100V-1US (optional) Bathroom controller: BC-100V-1US (optional) MCC-91-2US (optional; for hydronic and commercial applications)

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 12 inches(305mm)  Back of heater - 0 inches  Bottom of heater - 12 inches(305mm)  Front (Panel) - 24 inches(610mm)  Front (Exhaust) - 24 inches(610mm)  Sides of heater - 6 inches(152mm)

Clearances from Non-combustibles

 Top of heater - 2 inches(51mm)  Front (Panel) - 0 inches * Front (Exhaust) - 24 inches(610mm)

* 24 inches required for serviceability

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

 Back of heater - 0 inches  Bottom of heater - 2 inches(51mm)  Sides of heater - 1/8 inch(3.2mm)

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (10mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.) (sea level)

Natural Gas: high fire 2.5” W.C. (6.23mbar) low fire 0.52” W.C. (1.30mbar) Propane Gas: high fire 4.5” W.C. (11.21mbar) low fire 0.80” W.C. (2.00mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels Heat exchanger: 10 years* for residential and hydronic applications, increased to 12 years* if installed with an isolation valve kit; All other parts: 5 years*; Labor: 1 year (* reduced to 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater) Refer to the manual for complete warranty information.

DIMENSIONS

WEIGHT: 44.3 lb (20.1 kg)

14.04 (356.6)

2.23 (56.6)

Limited Warranty

0.28 (7.2)

9.27 (235.5)

0.59 (15)

8.90 (226)

C

F G

E D

22.95 (583)

1.14 (29)

B

A

DIMENSION

Inches (mm)

DIMENSION

Inches (mm)

A (GAS)

1.31 (33.2)

D

4.33 (110)

A (COLD)

1.93 (49)

E

2.91 (73.8)

A (HOT)

1.35 (34.4)

F

1.61 (40.8)

B

3.96 (100.7)

G

2.87 (73)

C

1.17 (29.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


RUCS65i (KCM2025FFU) Type of Appliance

Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified

Rinnai model number

REU-KCM2025FFU-US

Operation / Installation

Forced combustion; indoor only; Certified for installation in Manufactured (Mobile) Homes

Minimum/Maximum Gas Rate (Input)

10,300 - 130,000 BTU/h

Electrical

Appliance: Temperature Controller:

Electrical Consumption

Normal: 89 w

Standby: 1.3 w Anti-frost protection: 167 w

Amperage

Max: 2.3A

Fuse: 10A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)

Temperature (with remote)

120° - 140° F (49°- 60°C)

Temperature (without remote)

120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)

Approved Gas Types

Natural or Propane (ensure unit matches gas type)

Uniform Energy Factor (UEF)

0.90

Service Connections

Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control and fixed by-pass

Minimum/Maximum Water Supply Pressure

50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)

High Altitude Capability

Up to 5,400 ft (1646 m) elevation above sea level

AC 120 Volts - 60 Hz DC 12 Volts

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

FLOW TABLE

10.0 (37.9)

Water Flow gpm (l/min)

9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0

25 (13.9) 50 (27.8) 75 (41.6) delta T - Temperature Rise ºF (ºC) © 2017 Rinnai Corporation

RUCS65i-SP-2

100 (55.6)

5/2017 C

US

Low Lead Content NSF/ANSI 372

SANITATION

125 (69.4)

150 (83.3)


RUCS65i (KCM2025FFU) Controller (Optional)

MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 6 inches (152mm)  Back of heater - 0 inches  Front of heater - 6 inches *(152mm)  Bottom of heater - 12 inches (305mm)  Sides of heater - 2 inches (51mm)  From vent pipe - 0 inches

* 24 inches (610mm) required for service Clearances from Non-combustibles * 24 inches (610mm) required for service

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

 Top of heater - 2 inches (51mm)  Back of heater - 0 inches  Front of heater - 6 inches *(152mm)  Bottom of heater - 12 inches (305mm)  Sides of heater - 1/2 inches (13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.27” W.C. (5.7mbar) low fire 1.00” W.C. (2.5mbar) Propane Gas: high fire 2.58” W.C. (6.4mbar) low fire 1.08” W.C. (2.7mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Venting

Direct Vent system designed for use with Ubbink Polypropylene Concentric Vent, Twin Pipe PVC/CPVC (3” and 4” configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adapter) See installation and operation manual for details regarding installation and allowed vent lengths.

Limited Warranty

Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

WEIGHT: 57.3 lb (26 kg) 10.1 (257)

ø 5.5 (140.2) 5.9 (150)

2 (50.6)

1.2 (30.7)

DIMENSIONS

D

B C

H

A

28.5 (723)

25.7 (653.2)

31.1 (789.6)

E

F

I

G J

DIM

Inches (mm)

DIM

Inches (mm)

A (GAS)

1.3 (33.2)

D

0.09 (2.2)

A (COLD)

1.93 (49)

E

5.6 (142.3)

A (HOT)

1.35 (34.4)

F

3.24 (82.4)

G

3.99 (101.4)

H

1.58 (40.1)

I

3.17 (80.4)

J

18.3 (466)

A (CONDENSATE OUTLET)

0.94 (23.9)

B

3.93 (100)

C

1.91 (48.6)

8.73 (221.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


RUS65e (KCM2025W) Type of Appliance

Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified

Rinnai model number

REU-KCM2025W-US

Operation / Installation

Forced combustion; outdoor only; Certified for installation in Manufactured (Mobile) Homes

Minimum/Maximum Gas Rate (Input)

10,300 - 130,000 BTU/h

Electrical

Appliance: Temperature Controller:

Electrical Consumption

Normal: 61 w

Standby: 1.3 w

Amperage

Max: 2.3A

Fuse: 10A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1 l/min) Maximum flow rate: 6.5 GPM (24.6 l/min)

Temperature (with remote)

120° - 140° F (49°- 60°C)

Temperature (without remote)

120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)

Approved Gas Types

Natural or Propane (ensure unit matches gas type)

Uniform Energy Factor (UEF)

0.90

Service Connections

Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control and fixed by-pass

Minimum/Maximum Water Supply Pressure

50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)

High Altitude Capability

Up to 5,400 ft (1646 m) elevation above sea level

AC 120 Volts - 60 Hz DC 12 Volts Anti-frost protection: 140 w

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

FLOW TABLE

10.0 (37.9)

Water Flow gpm (l/min)

9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0

25 (13.9)

50 (27.8)

75 (41.6)

100 (55.6)

delta T - Temperature Rise ºF (ºC) © 2017 Rinnai Corporation

RUS65e-SP-2

5/2017 C

US

Low Lead Content NSF/ANSI 372

SANITATION

125 (69.4)

150 (83.3)


RUS65e (KCM2025FFW) Controller (Optional)

MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 12 inches (305mm)  Front (Panel) - 24 inches (610mm)  Front (Exhaust) - 24 inches (610mm)

 Back of heater - 0 inches  Bottom of heater - 12 inches (305mm)  Sides of heater - 6 inches (152mm)

Clearances from Non-combustibles

 Top of heater - 2 inches (51mm)  Front (Panel) - 0 inches *  Front (Exhaust) - 24 inches (610mm)

 Back of heater - 0 inches  Bottom of heater - 2 inches (51mm)  Sides of heater - 1/8 inch (3.2mm)

* 24 inches (610mm) required for service

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.02” W.C. (5.0mbar) low fire 0.89” W.C. (2.2mbar) Propane Gas: high fire 2.32” W.C. (5.8mbar) low fire 0.96” W.C. (2.4mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Limited Warranty

Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS

WEIGHT: 57.3 lb (26 kg) 18.5 (470)

0.4 (10.1)

10.1 (257)

9.4 (238)

D

4.6 (117.3)

18.5 (470) 9.4

4.6

B

25.7 (653.2)

0.44

A

28.4 (721.4)

0.44 (11.1)

C

H E

F

I

G J

DIM

Inches (mm)

DIM

A (GAS)

1.3 (33.2)

D

0.09 (2.2)

A (COLD)

1.93 (49)

E

5.6 (142.3)

A (HOT)

1.35 (34.4)

F

3.24 (82.4)

A (CONDENSATE OUTLET)

G

3.99 (101.4)

0.94 (23.9)

H

1.58 (40.1)

B

3.93 (100)

I

3.17 (80.4)

C

1.91 (48.6)

J

18.3 (466)

Inches (mm)

8.73 (221.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


RUCS75i (KCM2528FFU) Type of Appliance

Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified

Rinnai model number

REU-KCM2528FFU-US

Operation / Installation

Forced combustion; indoor only; Certified for installation in Manufactured (Mobile) Homes

Minimum/Maximum Gas Rate (Input)

10,300 - 160,000 BTU/h

Electrical

Appliance: Temperature Controller:

Electrical Consumption

Normal: 89 w

Standby: 1.3 w Anti-frost protection: 167 w

Amperage

Max: 2.3A

Fuse: 10A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)

Temperature (with remote)

120° - 140° F (49°- 60°C)

Temperature (without remote)

120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)

Approved Gas Types

Natural or Propane (ensure unit matches gas type)

Uniform Energy Factor (UEF)

0.90

Service Connections

Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control and fixed by-pass

Minimum/Maximum Water Supply Pressure

50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)

High Altitude Capability

Up to 5,400 ft (1646 m) elevation above sea level

AC 120 Volts - 60 Hz DC 12 Volts

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

FLOW TABLE

10.0 (37.9)

Water Flow gpm (l/min)

9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0

25 (13.9) © 2017 Rinnai Corporation

RUCS75i-SP-2

50 (27.8) 75 (41.6) 100 (55.6) delta T - Temperature Rise ºF (ºC) 5/2017 C

US

Low Lead Content NSF/ANSI 372

SANITATION

125 (69.4)

150 (83.3)


RUCS75i (KCM2528FFU) Controller (Optional)

MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 6 inches (152mm)  Back of heater - 0 inches  Front of heater - 6 inches *(152mm)  Bottom of heater - 12 inches (305mm)  Sides of heater - 2 inches (51mm)  From vent pipe - 0 inches

* 24 inches (610mm) required for service Clearances from Non-combustibles * 24 inches (610mm) required for service

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

 Top of heater - 2 inches (51mm)  Back of heater - 0 inches  Front of heater - 6 inches *(152mm)  Bottom of heater - 12 inches (305mm)  Sides of heater - 1/2 inches (13mm)  From vent pipe - 0 inches

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 3.37” W.C. (8.4mbar) low fire 1.00” W.C. (2.5mbar) Propane Gas: high fire 3.75” W.C. (9.3mbar) low fire 1.08” W.C. (2.7mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Venting

Direct Vent system designed for use with Ubbink Polypropylene Concentric Vent, Twin Pipe PVC/CPVC (3” and 4” configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adapter) See installation and operation manual for details regarding installation and allowed vent lengths.

Limited Warranty

Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

WEIGHT: 57.3 lb (26 kg) 10.1 (257)

ø 5.5 (140.2) 5.9 (150)

2 (50.6)

1.2 (30.7)

DIMENSIONS

D

B C

H

A

28.5 (723)

25.7 (653.2)

31.1 (789.6)

E

F

I

G J

DIM

Inches (mm)

DIM

Inches (mm)

A (GAS)

1.3 (33.2)

D

0.09 (2.2)

A (COLD)

1.93 (49)

E

5.6 (142.3)

A (HOT)

1.35 (34.4)

F

3.24 (82.4)

G

3.99 (101.4)

H

1.58 (40.1)

I

3.17 (80.4)

J

18.3 (466)

A (CONDENSATE OUTLET)

0.94 (23.9)

B

3.93 (100)

C

1.91 (48.6)

8.73 (221.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


RUS75e (KCM2528W) Type of Appliance

Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified

Rinnai model number

REU-KCM2528W-US

Operation / Installation

Forced combustion; outdoor only; Certified for installation in Manufactured (Mobile) Homes

Minimum/Maximum Gas Rate (Input)

10,300 - 160,000 BTU/h

Electrical

Appliance: Temperature Controller:

Electrical Consumption

Normal: 61 w

Standby: 1.3 w Anti-frost protection: 140 w

Amperage

Max: 2.3A

Fuse: 10A

Ignition System

Direct electronic ignition

Hot Water Capacity

Minimum flow rate: 0.26 GPM (1 l/min) Minimum activation flow rate: 0.4 GPM (1.5 l/min) Maximum flow rate: 7.5 GPM (28.4 l/min)

Temperature (with remote)

120° - 140° F (49°- 60°C)

Temperature (without remote)

120° F (49°C), 125° F (49°C), 135° F (57°C), or 140° F (60°C)

Approved Gas Types

Natural or Propane (ensure unit matches gas type)

Uniform Energy Factor (UEF)

0.90

Service Connections

Gas supply: 3/4 inch (19mm) MNPT Cold water inlet: 3/4 inch (19mm) MNPT Hot water outlet: 3/4 inch (19mm) MNPT

Water Flow Control

Water flow sensor, electronic water control and fixed by-pass

Minimum/Maximum Water Supply Pressure

50 - 150 PSI (345-1035 KPa) ( recommended 60 - 80 PSI (414 - 552 KPa) for optimal performance)

High Altitude Capability

Up to 5,400 ft (1646 m) elevation above sea level

AC 120 Volts - 60 Hz DC 12 Volts

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

FLOW TABLE

10.0 (37.9)

Water Flow gpm (l/min)

9.0 (34.1) 8.0 (30.3) 7.0 (26.5) 6.0 (22.7) 5.0 (19.0) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0.0

25 (13.9) © 2017 Rinnai Corporation

RUS75e-SP-2

50 (27.8) 75 (41.6) 100 (55.6) delta T - Temperature Rise ºF (ºC) 5/2017 C

US

Low Lead Content NSF/ANSI 372

SANITATION

125 (69.4)

150 (83.3)


RUS75e (KCM2528W) Controller (Optional)

MC-91-2US (optional maximum of 4 can be installed) Do not install MC-100V-1US or BC-100V-1US

Controller Cable

Non-polarized two-core cable, minimum 22 AWG

Safety Devices

   

Clearances from Combustibles

 Top of heater - 12 inches (305mm)  Back of heater - 0 inches  Front (Panel) - 24 inches (610mm)  Bottom of heater - 12 inches (305mm)  Front (Exhaust) - 24 inches (610mm)  Sides of heater - 6 inches (152mm)

Clearances from Non-combustibles

 Top of heater - 2 inches (51mm)  Back of heater - 0 inches  Front (Panel) - 0 inches *  Bottom of heater - 2 inches (51mm)  Front (Exhaust) - 24 inches (610mm)  Sides of heater - 1/8 inch (3.2mm)

* 24 inches (610mm) required for service

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Min. / Max. Gas Supply Pressure

Natural Gas: min 4” W.C. (2.5mbar) max 10.5” W.C. (26.1mbar) Propane Gas: min 8” W.C. (20mbar) max 13.5” W.C. (33.6mbar)

Manifold Gas Pressure (inches W.C.)

Natural Gas: high fire 2.97” W.C. (7.4mbar) low fire 0.89” W.C. (2.2mbar) Propane Gas: high fire 3.49” W.C. (8.7mbar) low fire 0.96” W.C. (2.4mbar)

NOx

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels

Limited Warranty

Heat exchanger: 12 years* for residential, All other parts: 5 years*; Labor: 1 year; (* 3 years if used as a circulating water heater within a circulation loop, when the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an aquastat / thermostat, timer, or an on-demand recirculation system is not incorporated.) Refer to the manual for complete warranty information.

DIMENSIONS

WEIGHT: 57.3 lb (26 kg) 18.5 (470) 9.4 (238)

0.4 (10.1)

10.1 (257)

D

4.6 (117.3)

H

28.4 (721.4)

E 25.7 (653.2)

0.44 (11.1)

B C

0.44 (11.1)

4.6 (117.3)

18.5 (470) 9.4 (238)

F

I

G J

DIM

Inches (mm)

DIM

A (GAS)

1.3 (33.2)

D

0.09 (2.2)

A (COLD)

1.93 (49)

E

5.6 (142.3)

A (HOT)

1.35 (34.4)

F

3.24 (82.4)

A (CONDENSATE OUTLET)

G

3.99 (101.4)

0.94 (23.9)

H

1.58 (40.1)

B

3.93 (100)

I

3.17 (80.4)

C

1.91 (48.6)

J

18.3 (466)

Inches (mm)

A 8.73 (221.8)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Vent-Free Fan Convectors The Rinnai Vent-Free Fan Convector is the perfect solution for rooms that are hard to heat. Incorporating a convection fan, this, gas-fired appliance evenly distributes comfortable warm air to eliminate cold spots in the most challenging installations.

Vent-Free Fan Convectors

Product Description

Min/Max Heating Input BTU

Fan Output (CFM Low / High)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs/kg)

Noise Level (dB/A)

List Price (U.S.)

FC510N

Fan Convector Vent Free Heater -10K BTU

5500/10000

67.8 / 97.8

23 x 22 x 13

26.5/12.0

28-38

$892

FC510P

Fan Convector Vent Free Heater -10K BTU

5600/10000

67.8 / 97.8

23 x 22 x 13

26.5/12.0

28-38

$892

FC824N

Fan Convector Vent Free Heater -24K BTU

8400/24000

109.5 / 215.4

27 x 22 x 13

33/14.9

30-44

$1,075

FC824P

Fan Convector Vent Free Heater -24K BTU

8000/22000

109.5 / 215.4

27 x 22 x 13

33/14.9

30-44

$1,075

Model Number

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • When ordering, please specify gas type with a “P” for Propane and a “N” for Natural Gas. Rinnai Vent-Free Fan Convectors are a supplemental heat source according to IFGC and should be used in applications as such. Codes vary from state to state. It is necessary to verify the approval of use of vent-free heaters based on local codes for your area. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial, federal and national gas fuel codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada, and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018


FC510 (RCE-391A-H) Type of Appliance

Vent free gas fan convection heater, suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RCE-391A-H-N (Natural gas)

RCE-391A-H-P (Propane)

Gas Rate Input (BTU/hour)

Low - 5,500 High - 10,000

Low - 5,600 High - 10,000

Minimum Gas Supply Pressure

3.5 in (135 mm) W.C.

8.0 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.5 in (267 mm) W.C

13.0 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 19 watts

Gas Connection

1/2 inch Male NPT

Combustion System

Ceramic Burner

Ignition System

Electronic spark ignition

Fan CFM Output

Low: 67.8

Temperature Settings

Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion

Temperature Control

Electronic thermostat

Weight

Approximately 22.1 lbs (10 kg)

Clearance from Combustibles

Side: 2 in. (50 mm), Top: 2 in. (50 mm), Front: 30 in. (762 mm) Back: 2 in. (50 mm), Bottom: 0 in.

Noise Level

Low-28dB

Warm Air Outlet

Bottom front louvers

Maximum Installation Elevation

5,200 Feet

FEATURES

High: 97.8

High-38dB

99.9% Efficient Cool-to-the-touch cabinet Modulating Technology Programmable Thermostat Child-Safety Lock Digital, Adaptive Control Electronic Iginition - No Pilot Light On Board Self-Diagnostics for Easier Maintenance Tilt Switch Push-Button, Electronic Ignition

© 2015 Rinnai Corporation

FC510 (RCE-391A-H SP)

7/2015

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


FC510 (RCE-391A-H) 

Safety Devices

Overheat Switch: The appliance will automatically shut down when the appliance exceeds a predetermined temperature. Flame Failure Device: The appliance will automatically shut down if the burner flame is extinguished.

Oxygen Depletion Sensor: If the oxygen level in the room drops below a preset limit, this sensor disables the gas supply to the heater.

Tilt Switch: If the heater is knocked over, the tilt switch will disable the gas supply. The fan will continue to purge. Convection fan continues to run after burner shutdown to cool internal parts.

Child Lock: Prevents inadvertent operation.

Power Failure: The appliance will disable the gas supply if it loses electrical power.

Fuse: The electrical circuits are protected by a fuse. When the 5 amp fuse blows, the heater will not operate until the 5 amp fuse is replaced.

Warranty

3 years from date of purchase on all parts

Conversion Kit

NA-Unit is not field convertible

ATTENTION This appliance is intended for supplemental heating only. The International Fuel Gas Code Standard 620-6 “Prohibited Use” states that “One or more unvented room heaters shall not be used as a sole source of comfort heating in any dwelling”.

19.2 in (487 mm)

19.4 in (492 mm)

DIMENSIONS

9.6 in (244 mm)

Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269 Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us ©2015 Rinnai America Corporation. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation.


FC824 (RCE-691TA-H) Type of Appliance

Vent free gas fan convection heater, suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RCE-691TA-H-N (Natural gas)

RCE-691TA-H-P (Propane)

Gas Rate Input (BTU/hour)

Low - 8,400 High - 24,000

Low - 8,000 High - 22,000

Minimum Gas Supply Pressure

5.0 in (135 mm) W.C.

8.0 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.0 in (266 mm) W.C

13.0 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 29 watts

Gas Connection

1/2 inch Male NPT

Combustion System

Ceramic Burner

Ignition System

Electronic spark ignition

Fan CFM Output

Low: 109.5

Temperature Settings

Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion

Temperature Control

Electronic thermostat

Weight

Approximately 26.5 lbs (12 kg)

Clearance from Combustibles

Side: 2 in. (50 mm), Top: 2 in. (50 mm), Front: 30 in. (762 mm) Back: 2 in. (50 mm), Bottom: 0 in.

Noise Level

Low-30dB

Warm Air Outlet

Bottom front louvers

Maximum Installation Elevation

5,200 Feet

FEATURES

High: 215.4

High-44dB

99.9% Efficient Cool-to-the-touch cabinet Modulating Technology Programmable Thermostat Child-Safety Lock Digital, Adaptive Control Electronic Ignition - No Pilot Light On Board Self-Diagnostics for Easier Maintenance Tilt Switch Push-Button, Electronic Ignition

© 2015 Rinnai Corporation

FC824 (RCE-691TA-H SP)

7/2015

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


FC824 (RCE-691TA-H) 

Safety Devices

Overheat Switch: The appliance will automatically shut down when the appliance exceeds a predetermined temperature. Flame Failure Device: The appliance will automatically shut down if the burner flame is extinguished.

Oxygen Depletion Sensor: If the oxygen level in the room drops below a preset limit, this sensor disables the gas supply to the heater.

Tilt Switch: If the heater is knocked over, the tilt switch will disable the gas supply. The fan will continue to purge. Convection fan continues to run after burner shutdown to cool internal parts.

Child Lock: Prevents inadvertent operation.

Power Failure: The appliance will disable the gas supply if it loses electrical power.

Fuse: The electrical circuits are protected by a fuse. When the 5 amp fuse blows, the heater will not operate until the 5 amp fuse is replaced.

Warranty

3 years from date of purchase on all parts

Conversion Kit

NA-Unit is not field convertible

ATTENTION This appliance is intended for supplemental heating only. The International Fuel Gas Code Standard 620-6 “Prohibited Use” states that “One or more unvented room heaters shall not be used as a sole source of comfort heating in any dwelling”.

24 in (610 mm)

19 in (482 mm)

DIMENSIONS

9.4 in (239 mm)

Rinnai America Corporation • 103 International Drive, Peachtree City, GA 30269 Toll-Free: 1-800-621-9419 • Phone: 678-829-1700 • www.rinnai.us ©2015 Rinnai America Corporation. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation.


EnergySaver® Direct Vent Wall Furnaces Designed to constantly monitor room temperatures, the Rinnai Direct Vent Wall Furnaces feature unique modulating technology that responds immediately to even the smallest temperature fluctuations.

Direct Vent Wall Furnaces Model Number

Min/Max Heating Input BTU

AFUE

Shipping Dimensions - Inches (W x H x D)

Shipping Weight lbs (kg)

Noise Level (dB/A)

List Price (U.S.)

EX08CTN

3000/8000

0.82

17 x 31 x 21

48 (21.8)

27-36

$1,385

EX08CTP

3000/8000

0.82

17 x 31 x 21

48 (21.8)

27-36

$1,385

EX11CTN

5500/11000

0.81

17 x 31 x 21

48 (21.8)

31-38

$1,657

EX11CTP

5700/11000

0.81

17 x 31 x 21

48 (21.8)

31-38

$1,657

EX17CTN

8200/16700

0.81

12 x 33 x 32.5

73 (33.1)

33-38

$1,983

EX17CTP

8200/16700

0.81

12 x 33 x 32.5

73 (33.1)

33-38

$1,983

EX22CTN

8200/21500

0.81

12 x 33 x 32.5

73 (33.1)

33-42

$2,192

EX22CTP

8200/20700

0.81

12 x 33 x 32.5

73 (33.1)

33-42

$2,192

EX22CTWN

8200/21500

0.81

12 x 33 x 32.5

73 (33.1)

33-42

$2,192

EX22CTWP

8200/20700

0.81

12 x 33 x 32.5

73 (33.1)

33-42

$2,192

EX38CTN

13200/38400

0.80

16.54 x 30.12 x 39.37

88 (39.9)

39-46

$2,612

EX38CTP

13200/36500

0.80

16.54 x 30.12 x 39.37

88 (39.9)

39-46

$2,612

EX38CTWN

13200/38400

0.80

16.54 x 30.12 x 39.37

88 (39.9)

39-46

$2,612

EX38CTWP

13200/36500

0.80

16.54 x 30.12 x 39.37

88 (39.9)

39-46

$2,612

Conversion Kits Item Number

TO NG

TO LP

List Price (U.S.)

EX08C

204000033

204000037

$11

EX11C

204000034

204000038

$11

EX17C

204000035

204000039

$11

EX22C / EX22CW

204000036

204000040

$11

EX38C / EX38CW

203000001

203000002

$95

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • When ordering, please specify gas type with a “P” for Propane and a “N” for Natural Gas. • All “T” Models require Rinnai Wall Thermostat Installation Kit 204000045 or 204000048 with customer supplied thermostat (2 or 3 wire type). Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 02/01/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Venting for Direct Vent Wall Furnaces Vent Terminations Item Number

Product Description

List Price (U.S.)

FOT-150

S Vent (3” - 4 1/2”)

$115

FOT-151

A Vent (4 1/2” - 9 1/2”) Included with each unit

$117

FOT-152

B Vent (9 1/2” - 15 3/4”)

$156

FOT-153

C Vent (15 3/4” - 23 5/8”)

$156

FOT-154

D Vent (23 5/8” - 31 1/2”)

$233

Extensions Item Number

Fits Model Number

Product Description

List Price (U.S.)

FOT-155

EX11C

12” - 20” Vent Pipe Extension

$102

FOT-156

EX11C

21” - 40” Vent Pipe Extension

$149

FOT-157

EX11C

60” - 80” Vent Pipe Extension

$183

FOT-158

EX11C / EX17C / EX22C

Elbow

$56

FOT-201

EX11C/ EX17C / EX22C

Long Elbow w/Intake Hose

$83

FOT-219

EX17C / EX22C

11” – 20” Vent Pipe Extension

$130

FOT-220

EX17C / EX22C

21” – 40” Vent Pipe Extension

$195

FOT-221

EX17C / EX22C

60” – 80” Vent Pipe Extension

$250

FOT-102

EX38C

11” - 20” Vent Pipe Extension

$125

FOT-103

EX38C

21” - 40” Vent Pipe Extension

$160

FOT-114

EX38C

60” - 80” Vent Pipe Extension

$207

FOT-115

EX38C

Elbow

$59

Extension Pipe Cover Kits & Wall Thermostat Installation Kits Item Number

Product Description

List Price (U.S.)

FOT-132*

Manifold Cover A for ES38, ES38W

$175

FOT-133*

Straight Cover A for ES38, ES38W

$238

FOT-134*

Elbow Cover A for ES38, ES38W

$107

FOT-140*

Manifold Cover B for EX11C, EX17C, EX22C (W)

$165

FOT-141*

Pipe Cover B for EX11C, EX17C, EX22C (W)

$143

FOT-142*

Elbow Cover B for EX11C, EX17C, EX22C (W)

$102

FOT-269

Relay Board Wall Thermostat

$115

204000045

Wall Thermostat Installation Kit (U.S. Market Only)

$80

204000048

Wall Thermostat Installation Kit (Canadian. Market Only)

$116

*Special order, confirm leadtimes.

2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 02/01/2018


EX08CT (RHFE-202FTA2) Type of Appliance

Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RHFE-202FTA2-N (Natural gas)

RHFE-202FTA2-P (Propane)

Gas Rate Input (BTU/hour)

Low - 3,000 High - 8,000

Low - 3,000 High - 8,000

Gas Rate Output (BTU/hour)

Low - 2,400 High - 6,400

Low - 2,400 High - 6,400

AFUE Rating

82%

Minimum Gas Supply Pressure

4.5 in (114 mm) W.C.

8 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 41 watts

Gas Connection

1/2 inch NPT

Combustion System

Stainless steel Bunsen burners

Ignition System

Electronic spark ignition

Fan CFM Output

Low - 48.3

Temperature Settings

Low (LO): minimum combustion 60°- 80° F in 2° increments High (HI): maximum combustion

Temperature Control

 Electronic thermostat  Temperature limiting program to comply with Inside Design Temperature limits

Humidifier Tray

Enameled tray with capacity of 1.5 pints (700 cc)

Weight

Approximately 46 lbs (21 kg)

Clearance from Combustibles

Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)

Noise Level

27 - 36 dB(A)

Warm Air Outlet

Bottom front louvers

High - 78.6

FEATURES Restart capability

Restarts automatically when ignition or combustion fails.

Timer Settings

Starts and turns off the heater at 2 timer settings.

Seven-stage modulating gas valve

Provides precise gas flow by operating from one to seven stages.

Negative coefficient thermistor

Detects temperature change in 1/2 of a degree.

Variable speed inducer motor with pressure switch

Monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph.

Self diagnostic electronics

Continually monitors functions; provides auto shutdown codes; indicates

Quiet operation

Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.

Wall Thermostat connectable

Ability to connect to a field supplied wall thermostat.

© 2017 Rinnai Corporation

RHFE-202FTA2 SP

8/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX08CT (RHFE-202FTA2) Safety Devices

 Flame rod detects flame failure; results in auto shutdown to prevent escape of gas  Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown  3 amp fuse protects against power surge; results in auto shutdown  Abnormal spark at time of ignition results in auto shutdown  Combustion fan purges any gas from the combustion chamber before ignition  Convection fan continues to run after burner shutdown to cool internal parts  Child lock prevents inadvertent operation  Appliance shuts down if room reaches 104° F (40° C)

Venting

Concentric; 3 1/8 inch (80 mm) wall hole

Maximum Vent Length

No extensions allowed; flue manifold termination connects directly to unit

Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)

Name

Kit No.

Fits Walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Warranty

Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years

Conversion Kit

To natural gas: 204000033

To propane gas: 204000037

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX08CT (RHFE-202FTA2)

Clearance for Maintenance

Clearance to Combustibles

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX08CT (RHFE-202FTA2)

Zone Cubic Feet Square Feet* 1

-5,470

-680

2

- 3,550

- 440

3

- 2,980

- 370

4

- 2,520

- 320

5

- 2,080

- 260

6

- 1,700

- 210

7

- 1,550

- 190

 Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai.

 In bathrooms, select a product equal to or less than 6000BTUH.  In bedrooms, select a product equal to or less than 10000BTUH.  In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider.

 Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer.

 Square footage column based off of an 8ft ceiling assumption.  The guidelines apply to average house construction.  This is intended to be used as a guide and not a replacement for a professionally engineered project.

 Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection.

 Sizing does not describe a complete system.  The contractor/engineer must determine the necessary components for and configuration of the particular system being installed.

 Sizing does not imply compliance with local building codes.  It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes.

 Confer with local building officials before installation.  RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation.  For primary heat applications, perform a Manual J sizing calculation.  Chart is to be used for supplemental heat applications only.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX11CT (RHFE-265FTA2) Type of Appliance

Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RHFE-265FTA2-N (Natural gas)

RHFE-265FTA2-P (Propane)

Gas Rate Input (BTU/hour)

Low - 5,500 High - 11,000

Low - 5,700 High - 11,000

Gas Rate Output (BTU/hour)

Low - 4,400 High - 8,800

Low - 4,560 High - 8,800

AFUE Rating

81%

Minimum Gas Supply Pressure

3.5 in (89 mm) W.C.

8 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 44 watts

Gas Connection

1/2 inch NPT

Combustion System

Stainless steel Bunsen burners

Ignition System

Electronic spark ignition

Fan CFM Output

Low - 96.4

Temperature Settings

Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion

Temperature Control

 Electronic thermostat  Temperature limiting program to comply with Inside Design Temperature limits

Humidifier Tray

Enameled tray with capacity of 1.5 pints (700 cc)

Weight

Approximately 46 lbs (21 kg)

Clearance from Combustibles

Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)

Noise Level

31 - 38 dB(A)

Warm Air Outlet

Bottom front louvers

High - 128.5

FEATURES Restart capability

Restarts automatically when ignition or combustion fails.

Timer Settings

Starts and turns off the heater at 2 timer settings.

Seven-stage modulating gas valve

Provides precise gas flow by operating from one to seven stages.

Negative coefficient thermistor

Detects temperature change in 1/2 of a degree.

Variable speed inducer motor with pressure switch

Monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph.

Self diagnostic electronics

Continually monitors functions; provides auto shutdown codes; indicates

Quiet operation

Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.

Wall Thermostat connectable

Ability to connect to a field supplied wall thermostat.

© 2017 Rinnai Corporation

RHFE-265FTA2 SP

8/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX11CT (RHFE-265FTA2) Safety Devices

 Flame rod detects flame failure; results in auto shutdown to prevent escape of gas  Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown  3 amp fuse protects against power surge; results in auto shutdown  Abnormal spark at time of ignition results in auto shutdown  Combustion fan purges any gas from the combustion chamber before ignition  Convection fan continues to run after burner shutdown to cool internal parts  Child lock prevents inadvertent operation  Appliance shuts down if room reaches 104° F (40° C)

Venting

Concentric; 3 1/8 inch (80 mm) wall hole

Maximum Vent Length

13 feet (4 m) with a maximum of 2 bends; maximum 8 ft (2.4 m) vertically for altitudes at or below 2000 ft (610 m) maximum 5 ft (1.5 m) vertically for altitudes above 200 ft (610 m)

Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)

Name

Kit No.

Fits Walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Warranty

Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years

Conversion Kit

To natural gas: 204000034

To propane gas: 204000038

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX11CT (RHFE-265FTA2)

Clearance for Maintenance

Clearance to Combustibles

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX11CT (RHFE-265FTA2)

Zone

Cubic Feet

Square Feet*

1

5,471 -7,430

681

-930

  

2

3,551 - 4,820

441

- 600

3

2,981 - 4,050

371

- 510

4

2,521 - 3,430

321

- 430

5

2,081 - 2,830

261

- 350

6

1,701 - 2,310

211

- 290

7

1,551 - 2,110

191

- 260

         

 

Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX17CT (RHFE-434FTA2) Type of Appliance

Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RHFE-434FTA2-N (Natural gas)

RHFE-434FTA2-P (Propane)

Gas Rate Input (BTU/hour)

Low - 8,200 High - 16,700

Low - 8,200 High - 16,700

Gas Rate Output (BTU/hour)

Low - 6,560 High - 13,360

Low - 6,560 High - 13,360

AFUE Rating

81%

Minimum Gas Supply Pressure

3.5 in (89 mm) W.C.

8 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 46 watts

Gas Connection

1/2 inch NPT

Combustion System

Stainless steel Bunsen burners

Ignition System

Electronic spark ignition

Fan CFM Output

Low: 110.5

Temperature Settings

Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion

Temperature Control

 Electronic thermostat  Temperature limiting program to comply with Inside Design Temperature limits

Humidifier Tray

Enameled tray with capacity of 2.1 pints (1000 cc)

Weight

Approximately 57 lbs (26 kg)

Clearance from Combustibles

Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)

Noise Level

33 - 38 dB(A)

Warm Air Outlet

Bottom front louvers

High: 141.3

FEATURES Restart capability

Restarts automatically when ignition or combustion fails.

Timer Settings

Starts and turns off the heater at 2 timer settings.

Seven-stage modulating gas valve

Provides precise gas flow by operating from one to seven stages.

Negative coefficient thermistor

Detects temperature change in 1/2 of a degree.

Variable speed inducer motor with

Monitors and controls combustion fan and allows the appliance to overcome

Self diagnostic electronics

Continually monitors functions; provides auto shutdown codes; indicates

Quiet operation

Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.

Wall Thermostat connectable

Ability to connect to a field supplied wall thermostat.

© 2017 Rinnai Corporation

RHFE-434FTA2 SP

8/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX17CT (RHFE-434FTA2) Safety Devices

 Flame rod detects flame failure; results in auto shutdown to prevent escape of gas  Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown  3 amp fuse protects against power surge; results in auto shutdown  Abnormal spark at time of ignition results in auto shutdown  Combustion fan purges any gas from the combustion chamber before ignition  Convection fan continues to run after burner shutdown to cool internal parts  Child lock prevents inadvertent operation  Appliance shuts down if room reaches 104° F (40° C)

Venting

Concentric; 3 1/8 inch (80 mm) wall hole

Maximum Vent Length

13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically

Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)

Name

Kit No.

Fits Walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Warranty

Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years

Conversion Kit

To natural gas: 204000035

To propane gas: 204000039

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX17CT (RHFE-434FTA2)

Clearance for Maintenance

Clearance to Combustibles

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX17CT (RHFE-434FTA2)

Zone

Cubic Feet

Square Feet*

1

7,431 -11,270 931

-1,410

  

2

4,821 - 7,310

601

- 910

3

4,051 - 6,150

511

- 770

4

3,431 - 5,200

431

- 650

   

5

2,831 - 4,290

351

- 540

6

2,311 - 3,510

291

- 440

7

2,111 - 3,210

261

- 400

     

 

Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX22CT (RHFE-559FTA2) Type of Appliance

Direct vent wall furnace suitable for homes, apartments, and condominiums, residential or commercial setting; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RHFE-559FTA2-N (Natural gas)

RHFE-559FTA2-P (Propane)

Gas Rate Input (BTU/hour)

Low - 8,200 High - 21,500

Low - 8,200 High - 20,700

Gas Rate Output (BTU/hour)

Low - 6,560 High - 17,200

Low - 6,560 High - 16,560

AFUE Rating

81%

Minimum Gas Supply Pressure

3.5 in (89 mm) W.C.

8 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 56 watts

Gas Connection

1/2 inch NPT

Combustion System

Stainless steel Bunsen burners

Ignition System

Electronic spark ignition

Fan CFM Output

Low: 110.5

Temperature Settings

Low (LO): minimum combustion 60° - 80° F in 2° increments High (HI): maximum combustion

Temperature Control

 Electronic thermostat  Temperature limiting program to comply with Inside Design Temperature limits

Humidifier Tray

Enameled tray with capacity of 2.1 pints (1000 cc)

Weight

Approximately 57 lbs (26 kg)

Clearance from Combustibles

Side: 2 inches (50 mm), Top: 0 inches (0 mm), Front: 40 inches (1 m)

Noise Level

33 - 42 dB(A)

Warm Air Outlet

Bottom front louvers

High: 162.7

FEATURES Restart capability

Restarts automatically when ignition or combustion fails.

Timer Settings

Starts and turns off the heater at 2 timer settings.

Seven-stage modulating gas valve

Provides precise gas flow by operating from one to seven stages.

Negative coefficient thermistor

Detects temperature change in 1/2 of a degree.

Variable speed inducer motor with pressure switch

Monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph.

Self diagnostic electronics

Continually monitors functions; provides auto shutdown codes; indicates

Quiet operation

Reduces noise through use of swept blades in convection fan; quiet expansion / contraction of parts due to temperature changes.

Wall Thermostat connectable

Ability to connect to a field supplied wall thermostat.

© 2017 Rinnai Corporation

RHFE-559FTA2 SP

8/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX22CT (RHFE-559FTA2) Safety Devices

 Flame rod detects flame failure; results in auto shutdown to prevent escape of gas  Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown  3 amp fuse protects against power surge; results in auto shutdown  Abnormal spark at time of ignition results in auto shutdown  Combustion fan purges any gas from the combustion chamber before ignition  Convection fan continues to run after burner shutdown to cool internal parts  Child lock prevents inadvertent operation  Appliance shuts down if room reaches 104° F (40° C)

Venting

Concentric; 3 1/8 inch (80 mm) wall hole

Maximum Vent Length

13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically

Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)

Name

Kit No.

Fits Walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Warranty

Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years

Conversion Kit

To natural gas: 204000036

To propane gas: 204000040

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX22CT (RHFE-559FTA2)

Clearance for Maintenance

Clearance to Combustibles

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX22CT (RHFE-559FTA2)

Zone

Cubic Feet

Square Feet*

1

11,271 -14,510 1,411 -1,810

2

7,311

- 9,410

911 - 1,180

3

6,151

- 7,920

771

- 990

4

5,201

- 6,700

651

- 840

       

5

4,291

- 5,530

541

- 690

6

3,511

- 4,520

441

- 570

7

3,211

- 4,130

401

- 520

     

 

Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX38CT (RHFE-1005FTA2) Type of Appliance

Direct vent wall furnace suitable for homes, apartments, and condominiums; modular/mobile home approved; forced combustion, forced convection

Rinnai Model Number

RHFE-1005FTA2-N (Natural gas) RHFE-1005FTA2-P (Propane)

Gas Rate Input (BTU/hour)

Low - 13,200 High - 38,400

Low - 13,200 High - 36,500

Gas Rate Output (BTU/hour)

Low - 10,560 High - 30,720

Low - 10,560 High - 29,200

AFUE Rating

80%

Minimum Gas Supply Pressure

3.5 in (89 mm) W.C.

8 in (203 mm) W.C.

Maximum Gas Supply Pressure

10.5 in (267 mm) W.C

13 in (330 mm) W.C.

Electrical Connection

AC 120V, 60 Hz, 117 watts

Gas Connection

1/2 inch FNPT

Combustion System

Stainless Steel Bunsen Burners

Ignition System

Electronic spark ignition

Temperature Settings

Low (LO): minimum combustion 60° - 80° F in 1° increments High (HI): maximum combustion

Temperature Control

 Electronic thermostat  Temperature limiting program to comply with Inside Design Temperature limits

Humidifier Tray

Enameled tray with capacity of 6.3 pints (3 liters)

Weight

Approximately 88 lbs (40 kg)

Clearance from Combustibles

Side: 2 inches (50 mm) Front: 40 inches (1 m)

Noise Level

39 - 46 dB(A)

Warm Air Outlet

Bottom front louvers

Top: 10 inches (250 mm)

FEATURES Timer Settings

Starts and turns off the heater at two timer settings

Seven-stage modulating gas valve

provides precise gas flow by operating from one to seven stages

Negative coefficient thermistor

detects temperature change in 1/2 of a degree

Variable speed inducer motor with pressure switch

monitors and controls combustion fan and allows the appliance to overcome winds of up to 40 mph

Quiet operation

reduces noise through use of swept blades in convection fan; and through the design of the combustion chamber and heat exchanger which silently

Self diagnostic electronic

continually monitors functions; provides auto shutdown codes; indicates

Wall Thermostat connectable

Ability to connect to a field supplied wall thermostat

© 2017 Rinnai Corporation

RHFE-1005FTA2-SP

8/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX38CT (RHFE-1005FTA2) Safety Devices

 Flame rod detects flame failure; results in auto shutdown to prevent escape of gas  Thermal fuse, and thermistor detect overheat condition; results in auto shutdown  5 amp fuse protects against power surge; results in auto shutdown  Abnormal spark at time of ignition results in auto shutdown  Combustion fan purges any gas from the combustion chamber before ignition  Convection fan continues to run after burner shutdown to cool internal parts  Function lock prevents inadvertent operation  Appliance shuts down if room reaches 104° F (40° C)

Venting

Concentric; 3 1/8 inch (80 mm) wall hole

Maximum Vent Length

13 feet (4 m) with a maximum of 2 bends

Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance)

Name

Kit No.

Fits Walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Wall Thermostat Kit

204000045 (US); 204000048 Canada

Warranty

Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. DIMENSIONS

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


EX38CT (RHFE-1005FTA2)

Clearance to Combustibles

Clearance for Maintenance

© 2016 Rinnai Corporation

RHFE-1005FTA2-SP

12/2016

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


EX38CT (RHFE-1005FTA2)

Zone

Cubic Feet

Square Feet*

   

1

14,5111 -25,600 1,811 -3,200

2

9,411 - 16,610 1181 - 2,080

3

7,921 - 13,960 991

- 1,750 

4

6,701 - 11,820 841

- 1,480 

5

5,531

- 9,750

691

- 1,220

6

4,521

- 7,980

571

- 1,000

7

4,131

- 7,280

521

- 910

        

 

Selection is based on installation locations at 2000ft or below. If the installation is above 2000ft please contact Rinnai. In bathrooms, select a product equal to or less than 6000BTUH. In bedrooms, select a product equal to or less than 10000BTUH. In single rooms in Region V, multiply the room’s volume by 3.20. The result is the maximum heat input (BTUH) of the product you should consider. Chart should not be used as the sole document for making final product selection. Consult with your Rinnai independent dealer. Square footage column based off of an 8ft ceiling assumption. The guidelines apply to average house construction. This is intended to be used as a guide and not a replacement for a professionally engineered project. Rinnai has not been to the location so this guidance is for your assistance only and should not be the sole factor in making a sizing selection. Sizing does not describe a complete system. The contractor/engineer must determine the necessary components for and configuration of the particular system being installed. Sizing does not imply compliance with local building codes. It is the responsibility of the engineer/contractor to ensure the installation is in accordance with all local building codes. Confer with local building officials before installation. RAC, its agents, employees, directors, officers, parent or affiliate companies assume no liability for damages arising from information provided herein to or by consumers or third parties or for damages arising from or associated with water quality, compliance with local codes, installation methods, materials or other circumstances related to application or installation. For primary heat applications, perform a Manual J sizing calculation. Chart is to be used for supplemental heat applications only.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


Condensing Gas Boilers For maximum momentum. Using proven technology, these boilers offer three distinct advantages above and beyond the average boiler. The M-Series condensing gas boiler from Rinnai is designed to provide fast, easier installation, operational performance with efficient heating, and simplified serviceability.

Rinnai M-Series Wall-Mounted Product Description

Min / Max Input-Heating (Btu/h & kW)

Min / Max Input - DHW (Btuh/kW)

Max Flow Rate Domestic Hot Water (70° F Delta T)

AFUE

Shipping Dimensions - Inches (W x H x D)

Shipping Weight (lbs/kg)

List Price (U.S.)

M060CN

Boiler Max HTG Btu 60K DHW 103K Combi, NG

17,000 / 60,000 (5.0 / 17.6)

17,000 / 103,000 (5.0 / 30.2)

2.6 / 9.8

95.0%

31.5 x 12 x 23

88/40

$3,380

M090CN

Boiler Max HTG Btu 90K DHW 160K Combi, NG

23,500 / 90,000 (6.9 / 26.4)

23,500 / 160,000 (6.9 / 46.9)

4.2 / 15.9

95.0%

31.5 x 12 x 23

95/43

$3,790

M120CN

Boiler Max HTG Btu 120K DHW 160K Combi, NG

23,500 / 120,000 (6.9 / 35.1)

23,500 / 160,000 (6.9 / 46.9)

4.2 / 15.9

95.0%

31.5 x 12 x 23

95/43

$3,895

M160CN

Boiler Max HTG DHW Btu 23,500 / 160,000 160,000 Combi, NG (6.9 / 46.9)

23,500 / 160,000 (6.9 /46.9)

4.2 / 15.9

95.0%

31.5 x 12 x 23

95/43

$4,175

Model Number Combi Boilers

Heat Only Boilers M060SN

Boiler Max HTG Btu 60,000 Solo, NG

17,000/ 60,000 (5.0 / 17.6)

N/A

N/A

95.0%

31.5 x 12 x 23

75/34

$2,965

M090SN

Boiler Max HTG Btu 90,000 Solo, NG

17,000 / 90,000 (5.0 / 26.4)

N/A

N/A

95.0%

31.5 x 12 x 23

75/34

$3,360

M120SN

Boiler Max HTG Btu 120,000 Solo, NG

23,500 / 120,000 (6.9 / 35.1)

N/A

N/A

95.0%

31.5 x 12 x 23

81/37

$3,375

M160SN

Boiler Max HTG Btu 160,000 Solo, NG

23,500 / 160,000 (6.9 / 46.9)

N/A

N/A

95.0%

31.5 x 12 x 23

81/37

$3,710

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • “C” in the model number is for “Combi”, “S” is “Solo”, • LP Conversion Kit included with all Natural Gas, “N” models. • Plumbing kit available for all models. • Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial, federal and national gas fuel codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (U.S.) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Condensing Gas Boilers Rinnai offers condensing gas boilers that can be easily retro-fitted to replace traditional less efficient boilers or provide simple, space-saving installation in new builds. They feature exclusive stainless steel heat exchanger to deliver unparalleled performance efficiency.

Rinnai E-Series Wall-Mounted Condensing Gas Boilers Product Description

Min / Max Input-Heating (Btuh/kW)

Min / Max Input - DHW (Btuh/kW)

Max Flow Rate Domestic Hot Water (70° F Delta T) GPM / LPM

AFUE

Shipping Dimensions Inch;es (W x H x D)

Shipping Weight (lbs/kg)

List Price (U.S.)

E50CRN

Combi Condensing Boiler

13,600 / 50,000 (4 / 14.6)

13,600 / 85,000 (4 / 24.9)

2.3/8.5

95.6%

20 x 26 x 16

93/42

$2,580

E75CRN

Combi Condensing Boiler

13,600 / 75,000 (4 / 22)

13,600 / 85,000 (4 / 24.9)

2.3/8.5

95.5%

20 x 26 x 16

96/44

E75CRP

Combi Condensing Boiler

37,000 / 75,000 (10.8 / 22)

37,000/85,000 (10.8 / 24.9)

2.3/8.5

95.5%

20 x 26 x 16

96/44

E110CRN

Combi Condensing Boiler

26,000 / 110,000 (7.6 / 32.2)

26,000 / 130,000 (7.6 / 38.1)

3.4/13.0

95.5%

20 x 34 x 16

110/50

E110CRP

Combi Condensing Boiler

59,000 / 110,000 (17.3 / 32.2)

59,000/130,000 (17.3 / 38.1)

3.4/13.0

95.5%

20 x 34 x 16

110/50

Model Number Combi Boilers

$2,790

$3,015

Heat Only Boilers E60SRN

Condensing Boiler Heat Only

13,600 / 60,000 (4 / 17.6)

N/A

N/A

95.6%

20 x 26 x 16

90/41

E60SRP

Condensing Boiler Heat Only

37,000 / 60,000 (10.8 / 17.6)

N/A

N/A

95.6%

20 x 26 x 16

90/41

E85SRN

Condensing Boiler Heat Only

13,600 / 85,000 (4 / 24.9)

N/A

N/A

95.4%

20 x 26 x 16

90/41

E85SRP

Condensing Boiler Heat Only

37,000 / 85,000 (10.8 / 24.9)

N/A

N/A

95.4%

20 x 26 x 16

90/41

E110SRN

Condensing Boiler Heat Only

26,000/110,000 (7.6 / 32.2)

N/A

N/A

95.5%

20 x 34 x 16

103/47

E110SRP

Condensing Boiler Heat Only

59,000 / 110,000 (17.3 / 32.2)

N/A

N/A

95.5%

20 x 34 x 16

103/47

$2,190

$2,395

$2,600

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • “C” in the model number is for “Combi”, “S” is “Solo”, “R” is for packaged with modulating pump, parameter changes and without Low Loss Header & Expansion Tank • E50CR model does not include the Concentric Flue Adaptor or Flow Switch. For LP applications, field conversion (NG to LP) is required. • For a list of approved installation venting options, refer to the Owner & Installation Manual.

2018 SUGGESTED LIST PRICE (U.S.) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Rinnai Q-Series Wall-Mounted Condensing Gas Boilers Product Description

Min / Max Input-Heating (Btuh/kW)

Min / Max Input - DHW GPM / LCM

Max Flow Rate Domestic Hot Water (70° F Delta T) GPM / LCM

AFUE

Shipping Dimensions Inch;es (W x H x D)

Shipping Weight (lbs/kg)

List Price (U.S.)

Q130SN

Condensing Boiler

26,000 / 130,000 (7.6/38.1)

N/A

Indirect tank compatible

95.4%

20 x 27 x 15

117/53

$4,250

Q130SP

Condensing Boiler

59,000 / 130,000 (17.3/38.1)

N/A

Indirect tank compatible

95.4%

20 x 27 x 15

117/53

$4,250

Q175SN

Condensing Boiler

35,000 / 175,000 (10.2/51.2)

N/A

Indirect tank compatible

95.0%

26 x 27 x 15

141/64

$4,800

Q175SP

Condensing Boiler

74,000 / 175,000 (21.7/51.2)

N/A

Indirect tank compatible

95.0%

26 x 27 x 15

141/64

$4,800

Q175CN

Condensing Boiler

35,000 / 175,000 (10.2/51.2)

6.2/23.5

4.4/16.6

95.0%

40 x 27 x 15

196/89

$5,800

Q175CP

Condensing Boiler

74,000 / 175,000 (21.7/51.2)

6.2/23.5

4.4/16.6

95.0%

40 x 27 x 15

196/89

$5,800

Q205SN

Condensing Boiler

41,000 / 205,000 (12/60)

N/A

Indirect tank compatible

95.0%

26 x 27 x 15

141/64

$5,200

Q205SP

Condensing Boiler

74,000 / 205,000 (21.7/60)

N/A

Indirect tank compatible

95.0%

26 x 27 x 15

141/64

$5,200

Model Number

Rinnai Q Premier Gas Boilers Model Number

QP130N

Product Description

Min / Max Input-Heating (Btuh/kW)

First Hour Rating (Gallons)

Max Flow Rate Domestic Hot Water (70° F Delta T) GPM / LCM

AFUE

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs/kg)

List Price (U.S.)

Condensing Boiler/ Tank

26,000 / 130,000 (7.6 / 38.1)

211

3.4/13.0

95.4%

24 x 62 x 25

243/110

$6,500

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. • “C” in the model number is for “Combi”, “S” is “Solo”, “QP” is for “Q Premier” All-in-one-system • E50CR model does not include the Concentric Flue Adaptor or Flow Switch. For LP applications, field conversion (NG to LP) is required. • For a list of approved installation venting options, refer to the Owner & Installation Manual.

2018 SUGGESTED LIST PRICE (U.S.) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Accessories for Boilers Item Number 803000023

Product Description Plumbing Kit, M-Series Boiler

List Price (U.S.) $333

804000074

Kit, Condensate Neutralizer (All Models)

$85

809000114

Refill, Condensate Neutralizer (All Models)

$30

808000025

Air Intake Filter (All Models)

$132

809000024

Boiler Tool Kit (All Models)

$72

103000038

ScaleCutter System

$210

103000039

ScaleCutter Refill Cartridge

$110

MIVK-T-LW

Plumbing Isolation Valve Kit, Compact design, Ease in Flushing

$109

804000061

E-Series Low Loss Header Kit (LLH, T/P Gauge, Valves, PRV)

$460

804000071

E75C, E110C Side Mount for Low Loss Header Kit

$315

805000040

Flue Gas Sensor with Cable (All Models Excluding M-Series)

$70

808000023

Concentric Flue Adaptor / E50C

803000011

RS100 Room Controller (Excluding Q Premier, and M-Series)

$300

803000015

Flow Switch Conversion Kit / E50C

$176

$32

804000072

Q85S, Q130S Side Mount Low Loss Header Kit

$420

804000073

Q175S, Q175C, Q205S Side Mount Low Loss Header Kit

$525 $240

804000013

3-Way Diverter Valve Kit Q85S & Q130S

804000014

3-Way Diverter Valve Kit Q175S & Q205S

$240

804000079*

Pre-Bend Connect Kit for Q Premier (LEFT)

$500

804000080*

Pre-Bend Connect Kit for Q Premier (RIGHT)

$500

804000081*

Pre-Bend Connect Kit for Q Premier (TOP)

$500

* Pre-Bend Connect Kits are optional accessories for ease of installation.

2018 SUGGESTED LIST PRICE (U.S.) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Gas Conversion Kits Conversion Kits for NG to LP Item Number

Product Description

List Price (U.S.)

803000024

NG to LP Conversion Kit for M060C

$70

803000026

NG to LP Conversion Kit for M060S

$70

803000028

NG to LP Conversion Kit for M090C

$70

803000030

NG to LP Conversion Kit for M090S

$70

803000032

NG to LP Conversion Kit for M120C

$70

803000034

NG to LP Conversion Kit for M120S

$70

803000036

NG to LP Conversion Kit for M160C

$70

803000038

NG to LP Conversion Kit for M160S

$70

803000014

NG to LP Conversion Kit for E50C/E50CR

$48

803000016

NG to LP Conversion Kit for E60SR

$70

803000018

NG to LP Conversion Kit for E85SR

$70

803000020

NG to LP Conversion Kit for E110SR

$70

804000015

NG to LP Conversion Kit for E75C/E75CR

$70

804000016

NG to LP Conversion Kit for E110C/E110CR

$70

804000017

NG to LP Conversion Kit for Q85S

$135

804000018

NG to LP Conversion Kit for Q130S

$135

804000082

NG to LP Conversion Kit for QP85N

$132

804000083

NG to LP Conversion Kit for QP130N

$132

804000089

NG to LP Conversion Kit for Q175S (replaces 804000019)

$392

804000090

NG to LP Conversion Kit for Q175C (replaces 804000021)

$392

804000091

NG to LP Conversion Kit for Q205S (replaces 804000020)

$392

Conversion Kits for LP to NG Item Number

Product Description

List Price (U.S.)

803000025

LP to NG Conversion Kit for M060C

$70

803000027

LP to NG Conversion Kit for M060S

$70

803000029

LP to NG Conversion Kit for M090C

$70

803000031

LP to NG Conversion Kit for M090S

$70

803000033

LP to NG Conversion Kit for M120C

$70

803000035

LP to NG Conversion Kit for M120S

$70

803000037

LP to NG Conversion Kit for M160C

$70

803000039

LP to NG Conversion Kit for M160S

$70

803000017

LP to NG Conversion Kit for E60SR

$70

803000019

LP to NG Conversion Kit for E85SR

$70

803000021

LP to NG Conversion Kit for E110SR

$135

804000023

LP to NG Conversion Kit for E75C/E75CR

$70

804000024

LP to NG Conversion Kit for E110C/E110CR

$135

804000025

LP to NG Conversion Kit for Q85S

$135

804000026

LP to NG Conversion Kit for Q130S

$135

804000027

LP to NG Conversion Kit for Q175S

$135

804000028

LP to NG Conversion Kit for Q205S

$135

804000029

LP to NG Conversion Kit for Q175C

$135

Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial, federal and national gas fuel codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (U.S.) • Page 6 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


CONDENSING WALL-MOUNTED, GAS-FIRED SOLO BOILER (CENTRAL HEATING) Models

M060S, M090S, M120S, M160S

Appliance Type

Wall-Mounted, Gas-Fired Solo Boiler

Installation

Indoor

Gas Types

Natural Gas (or Propane with field conversion)

Standard Features

• • • • • •

Included with Purchase

• • • • • • • • • • •

Optional Accessories

Closely Spaced Tee/Manifold Kit, Flue Gas Temperature Sensor, Condensate Neutralizer, ScaleCutter, ScaleCutter Refill Cartridge, and Boiler Toolkit

Venting Options

• Direct Vent (Concentric and Twin Pipe) • Room Air • Materials: Polypropylene, Stainless Steel, PVC, CPVC

Measurements: in. (mm)

4.44 (113)

4.25 (108)

1.62 (41)

3.74 (95)

0.39 (10)

27.56 (700)

Factory Installed Modulating Pump Outdoor Reset Control System with Sensor Modulating Ceramic Burner Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Approved for Room and Closet Installations

Condensing Gas Boiler with Integrated Modulating Pump Liquid Propane Field Conversion Kit Wall Mounting Bracket Pressure Relief Valve Condensate Collector Kit Outdoor Reset Sensor Vent Top with Integrated 3 in. (80 mm) PP Adapters 3 in. (80 mm) PP to 3" PVC Adapter (Qty 2) 3 in. PVC to 2 in. PVC or 2 in. (60 mm) PP Adapter (Qty 2) 3 in. X 5 in. Concentric Vent Adapter NPT Adapters: − 1 in. (Qty 2) − 3/4 in. (Qty 1 for Gas Supply Connection) • Documentation: Installation and Operation Manual, User Manual, and ISCL (Installation, Service, and Commissioning Log)

Maximum Equivalent Vent Lengths Twin Pipe and Room Air: Vent Sizes Boiler Model

2 in. PVC and 2 in. (60 mm) PP 3 in. PVC and 3 in. (80 mm) PP M060S, M120S, M060S, M120S, M090S M160S M090S M160S Vent Lengths 60 ft (18 m) 30 ft (9 m) 150 ft (46 m) 140 ft (43 m)

10.46 (266)

17.32 (440)

Gas

Concentric: Vent Sizes Boiler Model Vent Lengths

2 in. X 4 in. M060S, M120S, M090S M160S 60 ft (18 m) 30 ft (9 m)

3 in. X 5 in. M060S, M120S, M090S M160S 150 ft (46 m) 140 ft (43 m)

45° elbow equivalent to 3 ft (1 m). 90° elbow equivalent to 6 ft (2 m). 3.98 (101)

Central Heating Supply

Central Heating Return

2.36 (60) 8.66 (220) 14.96 (380)

● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Model Dimensions (w, h, d) Weight

M060S

M090S

Unit

− Convenient mounting

Shipping

75 lb. (34 kg)

81 lb. (37 kg)

bracket − NPT threads for connection points − More flexible venting options − Simplified parameters for commissioning and setup

Direct Electronic Ignition Stainless Steel 7.3 sq ft

11.8 sq ft

(Min - Max) 68° F - 185° F (20° C - 85° C) 1 Gal. (3.8 L)

1.4 Gal. (5.2 L)

Min

NG: 17,000 LP: 31,500

Max

60,000

NG: 23,500 LP: 73,500

90,000

57 MBH (17 kWh)

84 MBH (25 kWh)

160,000

112 MBH (33 kWh)

148 MBH (43 kWh)

Minimum: 14 PSI (97 kPa) Maximum: 45 PSI (310 kPa)

PRV

375 MBH (110 kWh) 30 PSI (207 kPa)

PRV Rating

UPER 15-78

Sound Level Normal

39 dB

42 dB

155 W

177 W

Standby Max Current

1.62 Amps

164 W

191 W

1.8 Amps

1.67 Amps

1.97 Amps

5 Amps

Clearances

− − − − − −

Top: 2 in. (51 mm)* Bottom: 12 in. (305 mm) Front: 6 in. (152 mm)** Back: 0 in. Sides: 2 in. (51 mm) Vent: 0 in. * 0 in. from vent components. 6 in. (152 mm) for closet installations. ** Clearance for servicing is 24 in. (610 mm) in front of boiler.

8.0 in. - 13.5 in. W.C. (19.9 - 33.6 mbar)

Propane

Electric Voltage

Warranty

AC 120 V, 60 Hz.

Electric Voltage Controls

Residential: −Heat Exchanger: 12 Years

24 V

Circuit Breaker Rating

ENERGY STAR® Certification

54 dB

3.0 in. - 10.5 in. W.C. (7.5 - 26 mbar)

Natural Gas

Turndown Ratio (TDR) Available Pressure Drop at Maximum Input Rate AFUE

48 dB 3.5 W

Fuse

Certifications

120,000

CH

Pump Model

1

design

70 lb. (32 kg)

Temperature Setting

Gas Supply Pressure1

− Compact & lightweight

64 lb. (29 kg)

Heat Exchanger Surface Area

Electrical Data

Faster, Easier Installation

Unit

Heat Exchanger Material

Water Supply Pressure

M160S

12 in. x 23 in. x 31.5 in. (305 mm x 585 mm x 800 mm)

Shipping

Ignition System

Water Content Gas Consumption (Btu/h) Heating Capacity

M120S

17 in. x 28 in. x 10 in. (439 mm x 699 mm x 264 mm)

15 A (Recommended) 3.5:1 / 1.9:1

5.3:1 / 2.9:1

5.1:1 / 1.6:1

6.8:1 / 2.2:1

21.1 ft at 3.2 GPM

16.9 ft at 4.8 GPM

9.5 ft at 6.3 GPM

4.8 ft at 7.5 GPM

95.0% Yes. Recognized as the Most Efficient of ENERGY STAR® 2018 ANSI Z21.13, CSA 4.9

Maximum gas supply pressure must not exceed the value specified by the manufacturer.

−All Other Parts/ Components: 2 Years

−Labor: 1 Year Commercial: − Heat Exchanger: 5 Years

− All Other Parts/ Components: 2 Years

− Labor: 1 Year Important

− If the boiler is to be installed in a system that has multiple zones, a Closely Spaced Tee/ Manifold Kit is recommended to be installed.

− If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator, a Closely Spaced Tee/Manifold Kit must be used. CH = Central Heating PRV = Pressure Relief Valve


CONDENSING WALL-MOUNTED, GAS-FIRED SOLO BOILER (CENTRAL HEATING) Models

M060S, M090S, M120S, M160S

Appliance Type

Wall-Mounted, Gas-Fired Solo Boiler

Installation

Indoor

Gas Types

Natural Gas (or Propane with field conversion)

Standard Features

• • • • • •

Included with Purchase

• • • • • • • • • • •

Optional Accessories

Closely Spaced Tee/Manifold Kit, Flue Gas Temperature Sensor, Condensate Neutralizer, ScaleCutter, ScaleCutter Refill Cartridge, and Boiler Toolkit

Venting Options

• Direct Vent (Concentric and Twin Pipe) • Room Air • Materials: Polypropylene, Stainless Steel, PVC, CPVC

Measurements: in. (mm)

4.44 (113)

4.25 (108)

1.62 (41)

3.74 (95)

0.39 (10)

27.56 (700)

Factory Installed Modulating Pump Outdoor Reset Control System with Sensor Modulating Ceramic Burner Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Approved for Room and Closet Installations

Condensing Gas Boiler with Integrated Modulating Pump Liquid Propane Field Conversion Kit Wall Mounting Bracket Pressure Relief Valve Condensate Collector Kit Outdoor Reset Sensor Vent Top with Integrated 3 in. (80 mm) PP Adapters 3 in. (80 mm) PP to 3" PVC Adapter (Qty 2) 3 in. PVC to 2 in. PVC or 2 in. (60 mm) PP Adapter (Qty 2) 3 in. X 5 in. Concentric Vent Adapter NPT Adapters: − 1 in. (Qty 2) − 3/4 in. (Qty 1 for Gas Supply Connection) • Documentation: Installation and Operation Manual, User Manual, and ISCL (Installation, Service, and Commissioning Log)

Maximum Equivalent Vent Lengths Twin Pipe and Room Air: Vent Sizes Boiler Model

2 in. PVC and 2 in. (60 mm) PP 3 in. PVC and 3 in. (80 mm) PP M060S, M120S, M060S, M120S, M090S M160S M090S M160S Vent Lengths 60 ft (18 m) 30 ft (9 m) 150 ft (46 m) 140 ft (43 m)

10.46 (266)

17.32 (440)

Gas

Concentric: Vent Sizes Boiler Model Vent Lengths

2 in. X 4 in. M060S, M120S, M090S M160S 60 ft (18 m) 30 ft (9 m)

3 in. X 5 in. M060S, M120S, M090S M160S 150 ft (46 m) 140 ft (43 m)

45° elbow equivalent to 3 ft (1 m). 90° elbow equivalent to 6 ft (2 m). 3.98 (101)

Central Heating Supply

Central Heating Return

2.36 (60) 8.66 (220) 14.96 (380)

● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Model Dimensions (w, h, d) Weight

M060S

M090S

Unit

− Convenient mounting

Shipping

75 lb. (34 kg)

81 lb. (37 kg)

bracket − NPT threads for connection points − More flexible venting options − Simplified parameters for commissioning and setup

Direct Electronic Ignition Stainless Steel 7.3 sq ft

11.8 sq ft

(Min - Max) 68° F - 185° F (20° C - 85° C) 1 Gal. (3.8 L)

1.4 Gal. (5.2 L)

Min

NG: 17,000 LP: 31,500

Max

60,000

NG: 23,500 LP: 73,500

90,000

57 MBH (17 kWh)

84 MBH (25 kWh)

160,000

112 MBH (33 kWh)

148 MBH (43 kWh)

Minimum: 14 PSI (97 kPa) Maximum: 45 PSI (310 kPa)

PRV

375 MBH (110 kWh) 30 PSI (207 kPa)

PRV Rating

UPER 15-78

Sound Level Normal

39 dB

42 dB

155 W

177 W

Standby Max Current

1.62 Amps

164 W

191 W

1.8 Amps

1.67 Amps

1.97 Amps

5 Amps

Clearances

− − − − − −

Top: 2 in. (51 mm)* Bottom: 12 in. (305 mm) Front: 6 in. (152 mm)** Back: 0 in. Sides: 2 in. (51 mm) Vent: 0 in. * 0 in. from vent components. 6 in. (152 mm) for closet installations. ** Clearance for servicing is 24 in. (610 mm) in front of boiler.

8.0 in. - 13.5 in. W.C. (19.9 - 33.6 mbar)

Propane

Electric Voltage

Warranty

AC 120 V, 60 Hz.

Electric Voltage Controls

Residential: −Heat Exchanger: 12 Years

24 V

Circuit Breaker Rating

ENERGY STAR® Certification

54 dB

3.0 in. - 10.5 in. W.C. (7.5 - 26 mbar)

Natural Gas

Turndown Ratio (TDR) Available Pressure Drop at Maximum Input Rate AFUE

48 dB 3.5 W

Fuse

Certifications

120,000

CH

Pump Model

1

design

70 lb. (32 kg)

Temperature Setting

Gas Supply Pressure1

− Compact & lightweight

64 lb. (29 kg)

Heat Exchanger Surface Area

Electrical Data

Faster, Easier Installation

Unit

Heat Exchanger Material

Water Supply Pressure

M160S

12 in. x 23 in. x 31.5 in. (305 mm x 585 mm x 800 mm)

Shipping

Ignition System

Water Content Gas Consumption (Btu/h) Heating Capacity

M120S

17 in. x 28 in. x 10 in. (439 mm x 699 mm x 264 mm)

15 A (Recommended) 3.5:1 / 1.9:1

5.3:1 / 2.9:1

5.1:1 / 1.6:1

6.8:1 / 2.2:1

21.1 ft at 3.2 GPM

16.9 ft at 4.8 GPM

9.5 ft at 6.3 GPM

4.8 ft at 7.5 GPM

95.0% Yes. Recognized as the Most Efficient of ENERGY STAR® 2018 ANSI Z21.13, CSA 4.9

Maximum gas supply pressure must not exceed the value specified by the manufacturer.

−All Other Parts/ Components: 2 Years

−Labor: 1 Year Commercial: − Heat Exchanger: 5 Years

− All Other Parts/ Components: 2 Years

− Labor: 1 Year Important

− If the boiler is to be installed in a system that has multiple zones, a Closely Spaced Tee/ Manifold Kit is recommended to be installed.

− If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator, a Closely Spaced Tee/Manifold Kit must be used. CH = Central Heating PRV = Pressure Relief Valve


E50CR Condensing Boiler Standard Features

Optional Accessories

           

       

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water Standard Built-in Domestic Hot Water Plate Heat Exchanger Modulating Ceramic Premix Burner 3.7:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Twin Pipe Venting Standard Approved For Room and Closet Installations (Zero Clearance to Combustibles)

RS100 Single Zone Controller Flue Gas Temperature Sensor Twin Pipe to Concentric Vent Adapters Room Air Filter NG to LP Conversion Kit Flow Switch Conversion Kit Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

0.9 Gal / 3.4 L

Fuel Type

Max. Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

50 MBH / 14.7 kWh

Heating Capacity

47 MBH / 13.8 kWh

Input (DHW)

85 MBH / 24.9 kWh

Minimum Input

13.6 MBH / 4.0 kWh

Turndown Ratio

3.7:1 TDR

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

45 psi / 310 kPa 375 MBH / 110 kWh 30 psi / 207 kPa 81 lbs / 37 kg

Min Inlet Gas Pressure NG

3.0" WC / 7.5 mbar

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

Electrical Voltage Mains Electrical Voltage Controls

NG

120 V / 60 Hz

System Pump Model Max Head Pressure at Flow Rate

24 V

UPER 20-58 6.7 ft at 5.0 GPM 2.0 m at 18.9 LPM

Power Consumption Max Load

145 W

AFUE

Power Consumption Standby Load

14 W

DHW Flow Rate 75°F ΔT

2.1 GPM / 7.9 LPM

Recommended Circuit Breaker Rating

15 A

DHW Minimum Activation

0.5 GPM / 2.0 LPM

Sound Level

39 dB Flow Restrictor Color

95.6%

Brown

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

E50CR-SP-2

8/2017


E50CR Condensing Boiler DIMENSIONS

Additional Information:

If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.

If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.

If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.

Shipping Specifications:

Shipping Weight: 93 lbs (42 Kg)

Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)

A

Height

25.6” / 650 mm

B

Width

19.7” / 500 mm

C

Depth

15.6” / 395 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to Center / Vent and Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

9.8” / 250 mm

H

Left Side / Supply Pipe

5.9” / 150 mm

J

Left Side / Return Pipe

13.8” / 350 mm

K

Left Side / Condensate Pipe

15.9” / 405 mm

N

Left Side / Cold water Pipe

11.2” / 285 mm

O

Left Side / Hot Water Pipe

8.5” / 215 mm

P

Pipe Length of G

1” / 26 mm

Q

Pipe Length of C

1.6” / 40 mm

R

Pipe length of F, K, R, and W

3.5” / 90 mm

S

Back / Center of Pipes C, K, and W

1” / 26 mm

T

Back / Center of Pipes F, G, and R

1.9” / 49 mm

V

Pipe Length Vent Co-axial Pipe Length Vent Parallel

3.7” / 95 mm 7” / 177 mm

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

0

10” / 250 mm

Back

0

0

Front

1” / 25 mm

24” / 600 mm

Left Side

0

2” / 50 mm

Right Side

0

2” / 50 mm

Floor / Ground

0

12” / 300 mm

Vent

0

0

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

E50CR-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


E60SR Condensing Boiler Standard Features

Optional Accessories

          

     

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Integrated Control for External Domestic Hot Water Indirect Tank Modulating Ceramic Premix Burner 4.4:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Concentric Venting System Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)

RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit DHW Indirect Tank Temperature Sensor

SPECIFICATIONS Performance Specifications

General Specifications Water Content

0.9 Gal / 3.4 L

Max. Supply Boiler Temperature

176 °F / 80 °C

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

45 psi / 310 kPa 375 MBH / 110 kWh 30 psi / 207 kPa 75 lbs / 34 kg

Min Inlet Gas Pressure NG

4.0" WC / 10.0 mbar

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

Electrical Voltage Mains Electrical Voltage Controls

120 V / 60 Hz 24 V

Power Consumption Max Load

145 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

39 dB

Fuel Types

NG and LP

Input (Heating)

60 MBH / 17.6 kWh

Heating Capacity

56 MBH / 16.4 kWh

Input (Domestic Hot Water) Minimum Input Turndown Ratio System Pump Model Max Head Pressure at Flow Rate AFUE

N/A NG: 13.6 MBH / 4.0 kWh LP: 37.0 MBH / 10.9 kWh 4.4:1 / 1.6:1 TDR UPER 20-58 7.3 ft at 5.0 GPM 2.2 m at 18.9 LPM 95.5%

DHW Flow Rate 75°F ΔT

N/A

DHW Minimum Activation

N/A

Flow Restrictor Color

N/A

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

E60SR-SP-2

8/2017


E60SR Condensing Boiler DIMENSIONS

Connection for combustion air supply and vent system A

Height

25.6” / 650 mm

B

Width

19.7” / 500 mm

C

Depth

15.6” / 395 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to Center / Vent & Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

9.8” / 250 mm

H

Left Side / Supply Pipe

5.9” / 150 mm

J

Left Side / Return Pipe

13.8” / 350 mm

K

Left Side / Condensate Pipe

15.9” / 405 mm

P

Pipe Length of G

1” / 26 mm

Q

Pipe Length of C

1.6” / 40 mm

S

Back / Center of Pipe C

T

Back / Center of Pipe F, G, and R

1.9” / 49 mm

V

Pipe Length Concentric Vent and Air Supply

7” / 177 mm

1” / 26 mm

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left side

2” / 50 mm

2” / 50 mm

Right side

2” / 50 mm

2” / 50 mm

Floor / Ground

0

12” / 300 mm

Vent

0

0

Additional Information: 

If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed. If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used. If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.

Shipping Specifications: 

Shipping Weight: 86 lbs (39 Kg)

Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

E60SR-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


E75CR Condensing Boiler Standard Features

Optional Accessories

           

     

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water Standard Built-in Domestic Hot Water Plate Heat Exchanger Modulating Ceramic Premix Burner 5.5:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)

RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Flow Switch Conversion Kit Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

0.9 Gal / 3.4 L

Fuel Types

Max. Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

75 MBH / 22.0 kWh

Heating Capacity

69 MBH / 20.2 kWh

Input (DHW)

85 MBH / 24.9 kWh

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

45 PSI/ 310 kPa 375 MBH/ 110 kWh 30 PSI / 207 kPa 82 lbs / 37 kg

Minimum Input

Min Inlet Gas Pressure NG

4.0" WC / 10.0 mbar

Turndown Ratio

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

Electrical Voltage Mains Electrical Voltage Controls

NG and LP

120 V / 60 Hz 24 V

Power Consumption Max Load

145 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

39 dB

System Pump Model Max Head Pressure at Flow Rate AFUE

NG: 13.6 MBH / 4.0 kWh LP: 37.0 MBH / 10.9 kWh 5.5:1 / 2.0:1 TDR UPER 20-58 6.7 ft at 5.0 GPM 2.0 m at 18.9 LPM 95.5%

DHW Flow Rate 75°F ΔT

2.1 GPM / 7.9 LPM

DHW Minimum Activation

0.5 GPM / 2.0 LPM

Flow Restrictor Color

Brown

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

E75CR-SP-2

8/2017


E75CR Condensing Boiler DIMENSIONS Connection for combustion air supply and vent system

A

Height

25.6” / 650 mm

B

Width

19.7” / 500 mm

C

Depth

15.6” / 395 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to Center / Vent and Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

9.8” / 250 mm

H

Left Side / Supply Pipe

5.9” / 150 mm

J

Left Side / Return Pipe

13.8” / 350 mm

K

Left Side / Condensate Pipe

15.9” / 405 mm

N

Left Side / Cold Water Pipe

11.2” / 285 mm

O

Left Side / Hot Water Pipe

8.5” / 215 mm

P

Pipe Length of G

1” / 26 mm

Q

Pipe Length of C

1.6” / 40 mm

R

Pipe Length of F, K, R, and W

3.5” / 90 mm

S

Back / Center of Pipes C, K, and E

1” / 26 mm

T

Back / Center of Pipes F, G, and R

1.9” / 49 mm

V

Pipe Length Vent Co-axial Pipe Length Vent Parallel

3.7” / 95 mm 7” / 177 mm

Additional Information:

If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.

If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.

Clearances

If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.

Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Shipping Specifications:

Right Side

2” / 50 mm

2” / 50 mm

Shipping Weight: 94 lbs (43 Kg)

Floor / Ground

12” / 300 mm

12” / 300 mm

Shipping Dimensions: 34”x17”x22” (86 cm x 44 cm x 55 cm)

0

0

Vent

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

E75CR-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


E85SR Condensing Boiler Standard Features

Optional Accessories

          

     

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Integrated Control for External Domestic Hot Water Indirect Tank Modulating Ceramic Premix Burner 6.25:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Concentric Venting System Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)

RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit DHW Indirect Tank Temperature Sensor

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

0.9 GAL / 3.4 L

Fuel Types

Max. Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

85 MBH / 24.9 kWh

Heating Capacity

78 MBH / 22.9 kWh

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight Min Inlet Gas Pressure NG

45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa 75 lbs / 34 kg

Input (DHW) Minimum Input

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

System Pump Model

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Head Pressure at Flow Rate

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

AFUE

Electrical Voltage Controls

N/A NG: 13.6 MBH / 4.0 kWh LP: 37.0 MBH / 10.9 kWh

4.0" WC / 10.0 mbar Turndown Ratio

Electrical Voltage Mains

NG and LP

120 V / 60 Hz

6.25:1 / 2.3:1 TDR UPER 20-58 7.3 ft at 5.0 GPM 2.2 m at 18.9 LPM 95.4%

DHW Flow Rate 75°F ΔT

N/A

DHW Minimum Activation

N/A

Flow Restrictor Color

N/A

24 V

Power Consumption Max Load

145 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

39 dB

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

E85SR-SP-2

8/2017


E85SR Condensing Boiler DIMENSIONS

Connection for combustion air supply and vent system

Height

25.6” / 650 mm

B

Width

19.7” / 500 mm

C

Depth

15.6” / 395 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to Center / Vent and Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

9.8” / 250 mm

H

Left Side / Supply Pipe

5.9” / 150 mm

J

Left Side / Return Pipe

13.8” / 350 mm

K

Left Side / Condensate Pipe

15.9” / 405 mm

P

Pipe Length of G

1” / 26 mm

Q

Pipe Length of C

1.6” / 40 mm

S

Back / Center of Pipe C

T

Back / Center of Pipes F, G, and R

1.9” / 49 mm

V

Pipe Length Concentric Vent and Air Supply

7” / 177 mm

1” / 26 mm

Clearances

Additional Information:

If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.

If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.

A

If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.

Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Right Side

2” / 50 mm

2” / 50 mm

12” / 300 mm

12” / 300 mm

0

0

Floor / Ground Vent

Shipping Specifications:

Shipping Weight: 86 lbs (39 Kg)

Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

E85SR-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


E110SR Condensing Boiler Standard Features

Optional Accessories

  

     

       

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Integrated Control for External Domestic Hot Water (DHW) Indirect Tank Modulating Ceramic Premix Burner 4.2:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Concentric Venting System Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)

RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit DHW Indirect Tank Temperature Sensor

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

1.3 Gal / 4.8 L

Fuel Types

NG and LP

Max. Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

110 MBH / 32.2 kWh

45 PSI / 310 kPa

Heating Capacity

101 MBH / 29.6 kWh

Input (DHW)

N/A

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight Min Inlet Gas Pressure NG

375 MBH/ 110 kWh 30 PSI / 207 kPa 81 lbs / 37 kg 4.0" / 10.0 mbar

Max Inlet Gas Pressure NG

10.5"/26.2 mbar

Min Inlet Gas Pressure LP

8.0" / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” / 33.6 mbar

Electrical Voltage Mains Electrical Voltage Controls

120 V / 60 Hz 24 V

Power Consumption Max Load

145 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

49 dB

Minimum Input

NG: 26 MBH / 7.6 kWh LP: 59 MBH / 17.4 kWh

Turndown Ratio

4.2:1 / 1.9:1TDR

System Pump Model

UPER 20-78

Max Head Pressure at Flow Rate

14.2 ft at 5.0 GPM 4.3 m at 18.9 LPM

AFUE

95.5%

DHW Flow Rate 75°F ΔT

N/A

DHW Minimum Activation

N/A

Flow Restrictor Color

N/A

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

E110SR-SP-2

8/2017


E110SR Condensing Boiler DIMENSIONS

Connection for combustion air supply and vent system

A

Height

25.6” / 650 mm

B

Width

19.7” / 500 mm

C

Depth

15.6” / 395 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to Center / Vent and Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

9.8” / 250 mm

H

Left Side / Supply Pipe

5.9” / 150 mm

J

Left Side / Return Pipe

13.8” / 350 mm

K

Left Side / Condensate Pipe

15.9” / 405 mm

P

Pipe Length of G

1” / 26 mm

Q

Pipe Length of C

1.6” / 40 mm

S

Back / Center of Pipe C

T

Back / Center of Pipes F, G, and R

1.9” / 49 mm

V

Pipe Length Concentric Vent and Air Supply

7” / 177 mm

1” / 26 mm

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used.

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Right Side

2” / 50 mm

2” / 50 mm

If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.

Floor / Ground

12” / 300 mm

12” / 300 mm

0

0

Additional Information:

If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed.

Vent

Shipping Specifications:

Shipping Weight: 92 lbs (42 Kg)

Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

E110SR-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


E110CR Condensing Boiler Standard Features

Optional Accessories

           

     

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard Built-in DHW Plate Heat Exchanger Modulating Ceramic Premix Burner 4.2:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Twin Pipe Venting Adapters Included Approved for Room and Closet Installations (Zero Clearance to Combustibles)

RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter Flow Switch Conversion Kit Low Loss Header Plumbing Kit Low Loss Header Side Mount Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

1.3 Gal / 4.8 L

Fuel Types

NG and LP

Max. Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

110 MBH / 32.2 kWh

45 PSI / 310 kPa

Heating Capacity

101 MBH / 29.6 kWh

375 MBH / 110 kWh

Input (DHW)

130 MBH / 38.1 kWh

Minimum Input

NG: 26 MBH / 7.6 kWh LP: 59 MBH / 17.4 kWh

Turndown Ratio

4.2:1 / 1.9:1 TDR

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

30 PSI / 207 kPa 92 lbs / 42 kg

Min Inlet Gas Pressure NG

4.0" WC / 10.0 mbar

System Pump Model

UPER 20-78

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Max Head Pressure at Flow Rate

13.8 ft at 5.0 GPM 4.2 m at 18.9 LPM

Min Inlet Gas Pressure LP

8.00" WC / 19.9 mbar

AFUE

95.5%

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

DHW Flow Rate 75°F ΔT

3.2 GPM / 12.1 LPM

DHW Minimum Activation

0.5 GPM / 2.0 LPM

Flow Restrictor Color

Green

Electrical Voltage Mains Electrical Voltage Controls

120 V / 60 Hz 24 V

Power Consumption Max Load

145 W

Power Consumption Standby Load

14 W

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Recommended Circuit Breaker Rating

15 A

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Sound Level

49 dB Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

E110CR-SP-2

8/2017


E110CR Condensing Boiler DIMENSIONS Connection for combustion air supply and vent system

A

Height

25.6” / 650 mm

B

Width

19.7” / 500 mm

C

Depth

15.6” / 395 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to center / Vent and Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

9.8” / 250 mm

H

Left Side / Supply Pipe

5.9” / 150 mm

J

Left Side / Return Pipe

13.8” / 350 mm

K

Left Side / Condensate Pipe

15.9” / 405 mm

N

Left Side / Cold Water Pipe

11.2” / 285 mm

O

Left Side / Hot Water Pipe

8.5” / 215 mm

P

Pipe Length of G

1” / 26 mm

Q

Pipe Length of C

1.6” / 40 mm

R

Pipe Length of F, K, R, and W

3.5” / 90 mm

S

Back / Center of Pipes C, K, and W

1” / 26 mm

T

Back / Center of Pipes F, G, and R

1.9” / 49 mm

V

Pipe Length Vent Co-axial Pipe Length Vent Parallel

3.7” / 95 mm 7” / 177 mm

Additional Information:

If the boiler is to be installed in a system that utilizes zone circulators and not zone valves a low loss header plumbing kit is required to be installed. If the pressure drop in the loop/system is greater than the available head pressure from the boiler circulator a Low Loss Header Plumbing kit part number: 804000061 must be used. If the boiler is installed in a system with zone valves and the constant recirculation function is activated then a differential pressure bypass valve or a low loss header plumbing kit is required to be installed.

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Right Side

2” / 50 mm

2” / 50 mm

12” / 300 mm

12” / 300 mm

0

0

Floor / Ground Shipping Specifications:

Shipping Weight: 104 lbs (47 Kg)

Shipping Dimensions: 34” x 17” x 22” (86 cm x 44 cm x 55 cm)

Vent

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

E110CR-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


Q130S Condensing Boiler Standard Features

Optional Accessories

  

     

       

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard (with Optional 3-way Valve, Not Included) Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations

3-way Valve DHW Kit RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

1.3 Gal / 5.0 L

Fuel Types

Max Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

130 MBH / 38.0 kWh

Heating Capacity

119 MBH / 34.9 kWh

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight Min Inlet Gas Pressure NG

45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa 117 lbs / 53 kg

Input (DHW) Minimum Input

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

System Pump Model

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Head Pressure at Flow Rate

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

AFUE

Electrical Voltage Controls

N/A NG: 26.0 MBH / 7.6 kWh LP: 59.0 MBH / 17.3 kWh

4.0" WC / 10.0 mbar Turndown Ratio

Electrical Voltage Mains

NG and LP

120 V / 60 Hz

5.0:1 / 2.2:1 TDR UPER 20-78 16.4 ft at 5.0 GPM 5.0 m at 18.9 LPM 95.4%

DHW Flow Rate 75°F ΔT

N/A

DHW Minimum Activation

N/A

Flow Restrictor Color

N/A

24 V

Power Consumption Max Load

144 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

50 dB

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

Q130S-SP-2

8/2017


Q130S Condensing Boiler DIMENSIONS

A

Height

26.8” / 680 mm

B

Width

19.7” / 500 mm

C

Depth

15.2” / 385 mm

D

Left Side / Vent

13.2” / 335 mm

E

Center to Center/Vent and Air Supply

4.7” / 120 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

2.6” / 65 mm

H

Left Side / Supply Pipe

7.8” / 199 mm

J

Left Side / Return Pipe

16.8” / 428 mm

K

Left Side / Condensate Pipe

14.6” / 370 mm

P

Pipe Length of G

0.7” / 18 mm

Q

Pipe Length of C

2” / 50 mm

R

Pipe Length of F and R

17.7” / 450 mm

T

Back / Center of Pipe C

1” / 25 mm

U

Back / Center of Pipe G

1.6” / 40 mm

V1 Back / Center of Pipes f1 and r1

2” / 50 mm

V2 Back / Center of Pipes f2 and r2

2.1” / 54 mm

W

Pipe Length Vent Co-axial Pipe Length Vent Parallel

2.6” / 65 mm 5.8” / 147 mm

X

Bottom Side Boiler to Center Pressure Relief Valve

7.7” / 195 mm

Y

Bottom Side Boiler to Center Low Loss Header

10.2” / 260 mm

Z

Center to Center of f2 to r2

9” / 229 mm

aa

Depth of Low Loss Header

5.6” / 142 mm

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Right Side

2” / 50 mm

2” / 50 mm

12” / 300 mm

30” / 762 mm

Floor / Ground to Bottom of Low Loss Header

0

12” / 300 mm

Vent

0

0

Floor / Ground

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

Q130S-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


Q175S Condensing Boiler Standard Features

Optional Accessories

  

     

       

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard (with Optional 3-way Valve, Not Included) Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations

3-way Valve DHW Kit RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

1.8 Gal / 7.0 L

Fuel Types

Max Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

175 MBH / 51.0 kWh

Heating Capacity

162 MBH / 47.5 kWh

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa 141 lbs / 64 kg

Input (DHW) Minimum Input

Min Inlet Gas Pressure NG

4.0" WC / 10.0 mbar

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

System Pump Model

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Head Pressure at Flow Rate

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

AFUE

Electrical Voltage Mains Electrical Voltage Controls

NG and LP

120 V / 60 Hz 24 V

Power Consumption Max Load

210 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

54 dB

Turndown Ratio

N/A NG: 35 MBH / 10.3 kWh LP: 74 MBH / 21.7 kWh 5.0:1 / 2.4:1 TDR UPER 20-78 16.4 ft at 5.0 GPM 5.0 m at 18.9 LPM 95.0%

DHW Flow Rate 75°F ΔT

N/A

DHW Minimum Activation

N/A

Flow Restrictor Color

N/A

Max Equivalent Exhaust Vent Length

80 ft / 24.4 m

Max Equivalent Combustion Air Vent Length

80 ft / 24.4 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

Q175S-SP-2

8/2017


Q175S Condensing Boiler DIMENSIONS

A

Height

26.8” / 680 mm

B

Width

26” / 660 mm

C

Depth

15.2” / 385 mm

D

Left Side / Vent

19.5” / 495 mm

E

Center to Center / Vent and Air Supply

4.7” / 121 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

2.6” / 65 mm

H

Left Side / Supply Pipe

7.8” / 199 mm

J

Left Side / Return Pipe

19.8” / 504 mm

K

Left Side / Condensate Pipe

20.9” / 530 mm

P

Pipe Length of G

0.7” / 18 mm

Q

Pipe Length of C

2” / 50 mm

R

Pipe Length of F and R

18.5” / 470 mm

T

Back / Center of Pipe C

1” / 25 mm

U

Back / Center of Pipe G

1.6” / 40 mm

V1 Back / Center of Pipes f1 and r1

2” / 50 mm

V2 Back/ Center of Pipes f2 and r2

2.1” / 54 mm

W

Pipe Length Vent Co-axial Pipe Length Vent Parallel

2.6” / 65 mm 5.8” / 147 mm

X

Bottom Side Boiler to Center Pressure Relief Valve

7.7” / 195 mm

Y

Bottom Side Boiler to Center Low Loss Header

10.2” / 260 mm

Z

Center to Center f2 to r2

aa

Depth of Low Loss Header

9” / 229 mm 5.6” / 142 mm

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Right Side

2” / 50 mm

2” / 50 mm

12” / 300 mm

30” / 762 mm

Floor / Ground to Bottom of Low Loss Header

0

12” / 300 mm

Vent

0

0

Floor / Ground

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

Q175S-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


Q175C Condensing Boiler Standard Features

Optional Accessories

           

    

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard Built in DHW 6.6 Gallon Indirect Tank Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations

RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content (Heating)

1.8 Gal / 7.0 L

Water Content (DHW)

3.7 Gal / 14 L

Max Supply Boiler Temperature

176 °F / 80 °C

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

375 MBH / 110 kWh 30 PSI / 207 kPa

Input (Heating)

175 MBH / 51.0 kWh

Heating Capacity

162 MBH / 47.5 kWh

Input (DHW)

175 MBH / 51.0 kWh

Minimum Input

196 lbs / 89 kg 4.0" WC / 10.0 mbar

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

Electrical Voltage Controls

NG and LP

45 PSI / 310 kPa

Min Inlet Gas Pressure NG

Electrical Voltage Mains

Fuel Types

Turndown Ratio System Pump Model Max Head Pressure at Flow Rate AFUE

NG: 35 MBH / 10.3 kWh LP: 74 MBH / 21.7 kWh 5.0:1 / 2.4:1 TDR UPER 20-78 15.9 ft at 5.0 GPM 4.8 m at 18.9 LPM 95.0%

DHW Flow Rate 75°F ΔT

4.1 GPM / 15.5 LPM

DHW Minimum Activation

N/A N/A

120 V / 60 Hz 24 V

Power Consumption Max Load

210 W

Flow Restrictor Color

Power Consumption Standby Load

14 W

80 ft / 24.4 m

Recommended Circuit Breaker Rating

Max Equivalent Exhaust Vent Length

15 A

80 ft / 24.4 m

Sound Level

54 dB

Max Equivalent Combustion Air Vent Length Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

Q175C-SP-2

8/2017


Q175C Condensing Boiler DIMENSIONS

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left side

2” / 50 mm

2” / 50 mm

Right side

2” / 50 mm

2” / 50 mm

12” / 300 mm

30” / 762 mm

Floor / Ground to bottom of Low Loss Header

0

12” / 300 mm

Vent

0

0

Floor / Ground

A

Height

26.8” / 680 mm

B

Width

39.4” / 1000 mm

C

Depth

15.2” / 385 mm

D

Left Side / Vent

19.5” / 495 mm

E

Center to Center / Vent and Air Supply

4.7” / 121 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

2.6” / 65 mm

H

Left Side / Supply Pipe

7.8” / 199 mm

J

Left Side / Return Pipe

19.8” / 504 mm

K

Left Side / Condensate Pipe

20.9” / 530 mm

L

Left Side / Expansion Tank

23.2” / 590 mm

N

Left Side / Cold Water Pipe

34.8” / 885 mm

O

Left Side / Hot Water Pipe

37.6” / 955 mm

P

Pipe Length of G

0.7” / 18 mm

Q

Pipe Length of C

2” / 50 mm

R

Pipe Length of F and R

18.5” / 470 mm

T

Back / Center of Pipe C

1” / 25 mm

U

Back / Center of Pipe G

1.6” / 40 mm

V1

Back / Center of Pipes f1, e, k, r1, and w

2” / 50 mm

V2 Back/ Center of Pipes f2 and r2

2.1” / 54 mm

W

Pipe Length Vent Co-axial Pipe Length Vent Parallel

2.6” / 65 mm 5.8” / 147 mm

X

Bottom Side Boiler to Center Pressure Relief Valve

8” / 200 mm

Y

Bottom Side Boiler to Center Low Loss Header

10.4” / 265 mm

Z

Center to Center of f2 and r2

12” / 305 mm

aa Depth of Low Loss Header

5.6” / 142 mm

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

Q175C-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


Q205S Condensing Boiler Standard Features

Optional Accessories

  

     

       

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Priority Domestic Hot Water (DHW) Standard (with Optional 3-way Valve, Not Included) Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations

3-way Valve DHW Kit RS100 Single Zone Controller Flue Gas Temperature Sensor Room Air Filter NG to LP Conversion Kit NG to LP Conversion Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content

1.8 Gal / 7.0 L

Fuel Types

Max Supply Boiler Temperature

176 °F / 80 °C

Input (Heating)

205 MBH / 60.0 kWh

Heating Capacity

186 MBH / 54.5 kWh

Max Operating Pressure Relief Valve Rating Relief Valve Pressure Rating Unit Weight

45 PSI / 310 kPa 375 MBH / 110 kWh 30 PSI / 207 kPa

Input (DHW)

141 lbs / 64 kg

Minimum Input

Min Inlet Gas Pressure NG

4.0" WC / 10.0 mbar

Turndown Ratio

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

Electrical Voltage Mains Electrical Voltage Controls

NG and LP

120 V / 60 Hz 24 V

Power Consumption Max Load

234 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

57 dB

System Pump Model Max Head Pressure at Flow Rate AFUE

N/A NG: 41 MBH / 12.0 kWh LP: 74 MBH / 21.7 kWh 5.0:1 / 2.8:1 TDR UPER 20-78 23.1 ft at 5.0 GPM 7.0 m at 18.9 LPM 95.0%

DHW Flow Rate 75°F ΔT

N/A

DHW Minimum Activation

N/A

Flow Restrictor Color

N/A

Max Equivalent Exhaust Vent Length

40 ft / 12.2 m

Max Equivalent Combustion Air Vent Length

40 ft / 12.2 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

Q205S-SP-2

8/2017


Q205S Condensing Boiler DIMENSIONS

A

Height

26.8” / 680 mm

B

Width

26” / 660 mm

C

Depth

15.2” / 385 mm

D

Left Side / Vent

19.5” / 495 mm

E

Center to Center / Vent and Air Supply

4.7” / 121 mm

F

Back / Vent

10.6” / 270 mm

G

Left Side / Gas Pipe

2.6” / 65 mm

H

Left Side / Supply Pipe

7.8” / 199 mm

J

Left Side / Return Pipe

19.8” / 504 mm

K

Left Side / Condensate Pipe

20.9” / 530 mm

P

Pipe Length of G

0.7” / 18 mm

Q

Pipe Length of C

2” / 50 mm

R

Pipe Length of F and R

18.5” / 470 mm

T

Back / Center of Pipe C

1” / 25 mm

U

Back / Center of Pipe G

1.6” / 40 mm

V1 Back / Center of Pipes f1 and r1

2” / 50 mm

V2 Back/ Center of Pipes f2 and r2

2.1” / 54 mm

W

Pipe Length Vent Co-axial Pipe Length Vent Parallel

2.6” / 65 mm 5.8” / 147 mm

X

Bottom Side Boiler to Center Pressure Relief Valve

7.7” / 195 mm

Y

Bottom Side Boiler to Center Low Loss Header

10.2” / 260 mm

Z

Center to Center f2 to r2

aa

Depth of Low Loss Header

9” / 229 mm 5.6” / 142 mm

Clearances Minimum required clearance to combustibles and non-combustibles

Recommended service clearances

Top

2” / 50 mm

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

2” / 50 mm

2” / 50 mm

Right Side

2” / 50 mm

2” / 50 mm

12” / 300 mm

30” / 762 mm

Floor / Ground to Bottom of Low Loss Header

0

12” / 300 mm

Vent

0

0

Floor / Ground

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

Q205S-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


QP130 Condensing Boiler Standard Features

Optional Accessories

             

 

Factory Installed Boiler/System Modulating Pump Onboard Outdoor Reset Control System with Sensor Standard Factory Installed Low Loss Header Priority Domestic Hot Water (DHW) Standard 24 Gallon Charged Indirect Stainless Steel Storage Tank Modulating Ceramic Premix Burner 5.0:1 Turndown Ratio Spark Ignition Exceeds SCAQMD 1146.2 Low NOx Requirements Stainless Steel Water Tube Condensing Heat Exchanger Direct Vent Sealed Combustion Concentric and Twin Pipe Venting Adapters Included Approved for Room and Closet Installations Pre-piped to Accept a DHW Recirculation Line

Room Air Filter NG to LP Conversion Kit

Piping Options   

Right Side Pre-bend Piping Kit Left Side Pre-bend Piping Kit Top Side Pre-bend Piping Kit

SPECIFICATIONS General Specifications

Performance Specifications

Water Content (Heating)

1.3 Gal / 5 L

Water Content (DHW)

24 Gal / 90 L

Max Supply Boiler Temperature

176 °F / 80 °C

Max Operating Pressure Relief Valve Rating

375 MBH / 110 kWh 30 PSI / 207 kPa

Unit Weight

243 lbs / 110 kg

Min Inlet Gas Pressure NG

4.0" WC / 10.0 mbar

Max Inlet Gas Pressure NG

10.5" WC / 26.2 mbar

Min Inlet Gas Pressure LP

8.0" WC / 19.9 mbar

Max Inlet Gas Pressure LP

13.5” WC / 33.6 mbar

Electrical Voltage Controls

NG and LP

Input (Heating)

130 MBH / 38.0 kWh

Heating Capacity

119 MBH / 34.3 kWh

Input (DHW)

130 MBH / 38.0 kWh

45 PSI / 310 kPa

Relief Valve Pressure Rating

Electrical Voltage Mains

Fuel Types

120 V / 60 Hz

Minimum Input Turndown Ratio System Pump Model AFUE DHW Flow Rate 75°F ΔT

10 Minute Peak Flow (75°F ΔT) DHW Minimum Activation

NG: 26.0 MBH / 7.6 kWh LP: 59.0 MBH / 17.3 kWh 5.0:1 / 2.2:1 TDR UPER 20-78 95.4% 3.2 GPM / 12.1 LPM 56 Gal / 212 L N/A

24 V

Power Consumption Max Load

176 W

Power Consumption Standby Load

14 W

Recommended Circuit Breaker Rating

15 A

Sound Level

50 dB

First Hour Rating Flow Restrictor Color

211 GPH / 799 LPH N/A

Max Equivalent Exhaust Vent Length

100 ft / 30.5 m

Max Equivalent Combustion Air Vent Length

100 ft / 30.5 m

Approved Venting Materials

Polypropylene, Stainless Steel, PVC, CPVC

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2017 Rinnai Corporation

QP130-SP-2

8/2017


QP130 Condensing Boiler DIMENSIONS P Q R

P Q R

S F

D

G

A

Height

61.8” / 1570 mm

B

Height Including Vent Connection

64.5” / 1640 mm

C

Width

23.6” / 600 mm

D

Depth

25.2” / 640 mm

E

Center Boiler / Vent

F

Back / Vent

18.5” / 470 mm

G

Center to Center / Vent and Air Supply

4.7” / 122 mm

3.7” / 95 mm

Connection Side: Left and Right E C

A B H

J K L

H

Bottom Side Boiler

Supply Pipe

48.4” / 1230 mm

J

Bottom Side Boiler

Return Pipe

45.7” / 1160 mm

K

Bottom Side Boiler

Hot Water Pipe Gas Pipe

42.9” / 1090 mm

L

Bottom Side Boiler

Cold Water Pipe DHW Circulation Return Pipe

40.2” / 1020 mm

M

Bottom Side Boiler

DHW Circulation Return Pipe Cold Water Pipe

37.4” / 950 mm

N

Bottom Side Boiler

Gas Pipe Hot Water Pipe

34.6” / 880 mm

0

Bottom Side Boiler

Condensate Pipe

26.0” / 662 mm

Connection Side: Top MN

P

Center boiler

Gas Pipe Hot Water Pipe

6.9” / 175 mm

Q

Center boiler

DHW Circulation Return Pipe Cold Water Pipe

4.1” / 105 mm

R

Center boiler

Supply Pipe Return Pipe

1.4” / 35 mm

S

Back boiler

Center of all Pipe Connections

1.2” / 30 mm

O

S

Clearances Minimum required clearance Recommended to combustibles and service clearances non-combustibles Top

0

10” / 250 mm

Back

0

0

Front

6” / 150 mm

24” / 600 mm

Left Side

0

2” / 50 mm

Right Side

0

2” / 50 mm

Vent

0

0

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us

© 2017 Rinnai Corporation

QP130-SP-2

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

8/2017


SENSEI™ Commercial Tankless Water Heaters (Condensing) Rinnai Commercial Condensing Tankless Water Heaters are precision-engineered to produce an endless supply of hot water for even the most demanding applications from restaurants to hotels to multi-family residences, schools and more. When the demands are greatest, Rinnai delivers.

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

List Price (U.S.)

CU199iN

Commercial Int CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 31.3

64

199,000

22.1 x 14.8 x 33.9

74

97%

$2,200

CU199iP

Commercial Int CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 31.3

64

199,000

22.1 x 14.8 x 33.9

74

97%

$2,200

CU199eN

Commercial Exterior CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 28.4

64

199,000

22.1 x 14.8 x 33.9

72

97%

$2,200

CU199eP

Commercial Exterior CTWH 199k Btu 11 gpm max w/Valve

18 x 11.4 x 28.4

64

199,000

22.1 x 14.8 x 33.9

72

97%

$2,200

CU160eN

Commercial Exterior CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 28.4

62

160,000

22.1 x 14.8 x 33.9

71

97%

$1,864

CU160eP

Commercial Exterior CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 28.4

62

160,000

22.1 x 14.8 x 33.9

71

97%

$1,864

CU160iN

Commercial Int CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 31.3

62

160,000

22.1 x 14.8 x 33.9

72

97%

$1,864

CU160iP

Commercial Int CTWH 160k Btu 9 gpm max w/Valve

18 x 11.4 x 31.3

62

160,000

22.1 x 14.8 x 33.9

72

97%

$1,864

Model Number

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit www.rinnai.us/warranty or call 1-800-621-9419. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Demand Duo™ Commercial Hybrid Water Heating Systems Combining the on-demand, continuous-supply technology of the Rinnai Tankless with an energy-efficient and durable 119-gallon and 80-gallon storage tank, the Demand Duo™ provides more water-heating capacity than a traditional tank in the first hour. These systems are perfect for emergency replacement situations with connection locations similar to most popular high-efficiency tanks. Models available include condensing and non-condensing tankless units. CHS199100CU CHS19980 CHS398100CU

Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Tank Capacity/ First Hour Delivery (Gallons)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency (or UEF)

List Price (U.S.)

CHS199100CUiN

Commercial Hybrid, Indoor, Max BTU 199,000, First 30.8 x 34.5 x 69.3 Hour Rating: 315 gph

430

199,000

119/ 315

48 x 37.25 x 78

490

97% (N/A)

$7,600

CHS199100CUiP

Commercial Hybrid, Indoor, Max BTU 199,000, First 30.8 x 34.5 x 69.3 Hour Rating: 315 gph

430

199,000

119/ 315

48 x 37.25 x 78

490

97% (N/A)

$7,600

RHS199100SEiN

Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 315 gph

30.8 x 34.5 x 69.3

430

199,000

119/ 315

48 x 37.25 x 78

490

97% (N/A)

$7,600

RHS199100SEiP

Residential Hybrid, Internal, Max BTU 199,000, First 30.8 x 34.5 x 69.3 Hour Rating: 315 gph

430

199,000

119/ 315

48 x 37.25 x 78

490

97% (N/A)

$7,600

CHS19980HEiN

Commercial Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph

27.7 x 34.1 x 64.7

290

199,000

80/ 259

34 x 24 x 63

450

N/A (0.81)

$5,800

CHS19980HEiP

Commercial Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph

27.7 x 34.1 x 64.7

290

199,000

80/ 259

34 x 24 x 63

450

N/A (0.81)

$5,800

CHS19980HEXiN

Commercial Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 251 gph

27.7 x 34.1 x 64.7

290

199,000

80/ 251

34 x 24 x 63

450

N/A (0.81)

$5,800

RHS19980HEiN

Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph

27.7 x 34.1 x 64.7

290

199,000

80/ 259

34 x 24 x 63

450

N/A (0.81)

$5,800

RHS19980HEiP

Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 259 gph

27.7 x 34.1 x 64.7

290

199,000

80/ 259

34 x 24 x 63

450

N/A (0.81)

$5,800

RHS19980HEXiN

Residential Hybrid, Indoor, Max BTU 199,000, First Hour Rating: 251 gph

27.7 x 34.1 x 64.7

290

199,000

80/ 251

34 x 24 x 63

450

N/A (0.81)

$5,800

Commercial Hybrid, Indoor, Max BTU 398,000, First 41.0 x 38.8 x 68.6 Hour Rating: 504 gph

530

398,000

119/504

Rack: 70 x 35 x 66 Tank: 48 x 37.25 x 78

890

97%

$14,200

Commercial Hybrid, Indoor, Max BTU 398,000, First 41.0 x 38.8 x 68.6 Hour Rating: 504 gph

530

398,000

119/504

Rack: 70 x 35 x 66 Tank: 48 x 37.25 x 78

890

97%

$14,200

NEW

CHS398100CUIN NEW

CHS398100CUIP

2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Tankless Rack Systems - Wall Mount (Condensing) The Rinnai Tankless Rack System™ is designed to supply a packaged water heating solution as a fully-assembled system. The TRS includes pre-assembled water and gas connections and manifolds under the tankless water heaters that are properly sized to maintain optimum performance.

TRW23CU

TRW03CU

TRW02CU Rinnai Tankless Wall Rack Systems

Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRW02CUeN

Exterior Wall Hanging Rack, 2 unit NG

44 x 14.1 x 54.8

169

398,000

70 x 35 x 66

390

0.97

N/A

$6,000

TRW02CUeP

Exterior Wall Hanging Rack, 2 unit LPG

44 x 14.1 x 54.8

169

398,000

70 x 35 x 66

390

0.97

N/A

$6,000

TRW02CUiN

Interior Wall Hanging Rack, 2 unit NG

44 x 14.1 x 54.8

170

398,000

70 x 35 x 66

391

0.97

N/A

$6,000

TRW02CUiP

Interior Wall Hanging Rack, 2 unit LPG

44 x 14.1 x 54.8

170

398,000

70 x 35 x 66

391

0.97

N/A

$6,000

TRW23CUeN

2-Unit Exterior Wall Hanging Rack NG

65 x 14.1 x 58

183

398,000

70 x 35 x 66

402

0.97

N/A

$6,000

TRW23CUeP

2-Unit Exterior Wall Hanging Rack LP

65 x 14.1 x 58

183

398,000

70 x 35 x 66

407

0.97

N/A

$6,000

TRW23CUiN

2-Unit Interior Wall Hanging Rack NG

65 x 14.1 x 58

186

398,000

70 x 35 x 66

407

0.97

N/A

$6,000

TRW23CUiP

2-Unit Interior Wall Hanging Rack LP

65 x 14.1 x 58

186

398,000

70 x 35 x 66

407

0.97

N/A

$6,000

TRW03CUeN

Exterior Wall Hanging Rack, 3 unit NG

65 x 14.1 x 54.8

244

597,000

70 x 35 x 66

465

0.97

N/A

$9,000

TRW03CUeP

Exterior Wall Hanging Rack, 3 unit LPG

65 x 14.1 x 54.8

244

597,000

70 x 35 x 66

465

0.97

N/A

$9,000

TRW03CUiN

Interior Wall Hanging Rack, 3 unit NG

65 x 14.1 x 54.8

248

597,000

70 x 35 x 66

469

0.97

N/A

$9,000

TRW03CUiP

Interior Wall Hanging Rack, 3 unit LPG

65 x 14.1 x 54.8

248

597,000

70 x 35 x 66

469

0.97

N/A

$9,000

2018 SUGGESTED LIST PRICE (USD) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Tankless Rack Systems - ST/SE Models (Commercial & Residential) Rinnai SE+ Series Tankless Rack System™ (SE Model) features a sturdy, pre-assembled rack using two super high-efficiency RU199i or RU199e units, providing homeowners with an endless supply of hot water, energy savings, a space saving design and a multitude of environmental benefits. Rinnai SE+ Series Tankless Rack System™ (ST Model) features wall hanging rack that provides redundancy, optimum performance and unparalleled durability. The RUR199i/e or RU199e featuring Rinnai ThermaCirc360™ make recirculation of hot water regardless of the current plumbing configuration. Paired with one or two RUC98i or RUC98e units, the rack will deliver an endless supply of hot water, energy savings, a space saving design and a multitude of environmental benefits.

TRW03ST

TRW02ST

TRW02SE Rinnai ST Series Tankless Wall Rack Systems (Super High-Efficiency with Recirculation) Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRW02STeN

Ext Wall Hanging Rack, 2 unit NG, w/RUR

44 x 14.1 x 58

177

398,000

70 x 35 x 66

398

0.97

0.93

$6,500

TRW02STeP

Ext Wall Hanging Rack, 2 unit LPG, w/RUR

44 x 14.1 x 58

177

398,000

70 x 35 x 66

398

0.97

0.93

$6,500

TRW02STiN

Interior Wall Hanging Rack, 2 unit NG, w

44 x 14.1 x 58

178

398,000

70 x 35 x 66

399

0.97

0.93

$6,500

TRW02STiP

Int Wall Hanging Rack, 2 unit LPG w/RUR

44 x 14.1 x 58

178

398,000

70 x 35 x 66

399

0.97

0.93

$6,500

TRW03STeN

Ext Wall Hanging Rack, 3 unit NG, w/RUR

65 x 14.1 x 58

254

597,000

70 x 35 x 66

472

0.97

0.93

$9,500

TRW03STeP

Ext Wall Hanging Rack, 3 unit LPG, w/RUR

65 x 14.1 x 58

254

597,000

70 x 35 x 66

472

0.97

0.93

$9,500

TRW03STiN

Int Wall Hanging Rack, 3 unit NG, w/RUR

65 x 14.1 x 58

258

597,000

70 x 35 x 66

476

0.97

0.93

$9,500

TRW03STiP

IntWall Hanging Rack, 3 unit LPG, w/RUR

65 x 14.1 x 58

258

597,000

70 x 35 x 66

476

0.97

0.93

$9,500

Rinnai SE Series Tankless Wall Rack Systems (Built with RU199) Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRW02SEeN

Ext Wall Hanging Rack, 2 unit NG, w/RU199

44 x 14.1 x 54.8

169

398,000

70 x 35 x 66

390

0.97

0.93

$5,700

TRW02SEeP

Ext Wall Hanging Rack, 2 unit LPG, w/RU199

44 x 14.1 x 54.8

169

398,000

70 x 35 x 66

390

0.97

0.93

$5,700

TRW02SEiN

Interior Wall Hanging Rack, 2 unit NG, w/ RU199

44 x 14.1 x 54.8

170

398,000

70 x 35 x 66

391

0.97

0.93

$5,700

TRW02SEiP

Int Wall Hanging Rack, 2 unit LPG w/RU199

44 x 14.1 x 54.8

170

398,000

70 x 35 x 66

391

0.97

0.93

$5,700

2018 SUGGESTED LIST PRICE (USD) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Tankless Rack Systems - Corner Rack (Condensing) Rinnai Tankless Rack Systems Corner Rack design solutions are great for food service, hospitality are designed to supply a packaged water heating solution as a fully-assembled system. The TRS includes pre-assembled water and gas connections and manifolds under the tankless water heaters that are properly sized to maintain optimum performance.

TRC02CU

Rinnai Tankless Corner Rack Systems Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRC02CUiN

Corner Rack Assembly Indoor 2 unit NG

32.9 x 32.9 x 45

224

398,000

48 x 50 x 31.5

356

0.97

N/A

$6,190

TRC02CUiP

Corner Rack Assembly Indoor 2 unit LPG

32.9 x 32.9 x 45

224

398,000

48 x 50 x 31.5

356

0.97

N/A

$6,190

2018 SUGGESTED LIST PRICE (USD) • Page 6 Š 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Tankless Rack Systems - HE Models (Non-Condensing) Rinnai HE+ Series Tankless Water Heaters are now available in a pre-assembled wall-hanging rack. Free up premium space with wall mount designs that provide redundancy, optimum performance and unparalleled durability. Using up to three highefficiency RL94i or RL94e is ideal for custom homes with high flow requirements such as multi-head showers and high volume garden or whirlpools tubs. The HE+ Tankless Rack System™ is also an excellent option for fast food or fast casual restaurants or other light commercial applications.

TRW02HE

TRW03HE

Rinnai HE Series Tankless Wall Rack Systems (Built with RU199) Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRW02HEeN

2-Unit Wall Hanging Rack, w/RL94

36.5 x 12.5 x 49.1

120

398,000

70 x 35 x 66

345

N/A

0.81

$5,400

TRW02HEeP

2-Unit Wall Hanging Rack, w/RL94

36.5 x 12.5 x 49.1

120

398,000

70 x 35 x 66

345

N/A

0.81

$5,400

TRW02HEiN

2-Unit Wall Hanging Rack, w/RL94

36.5 x 12.5 x 49.1

120

398,000

70 x 35 x 66

345

N/A

0.81

$5,400

TRW02HEiP

2-Unit Wall Hanging Rack, w/RL94

36.5 x 12.5 x 49.1

120

398,000

70 x 35 x 66

345

N/A

0.81

$5,400

TRW02HEXiN

2-Unit Wall Hanging Rack, w/RL94x

36.5 x 12.5 x 49.1

120

384,000

70 x 35 x 66

345

N/A

0.81

$5,400

TRW03HEeN

3-Unit Wall Hanging Rack, w/RL94

51.5 x 12.5 x 49.1

160

597,000

70 x 35 x 66

385

N/A

0.81

$8,100

TRW03HEeP

3-Unit Wall Hanging Rack, w/RL94

51.5 x 12.5 x 49.1

160

597,000

70 x 35 x 66

385

N/A

0.81

$8,100

TRW03HEiN

3-Unit Wall Hanging Rack, w/RL94

51.5 x 12.5 x 49.1

160

597,000

70 x 35 x 66

385

N/A

0.81

$8,100

TRW03HEiP

3-Unit Wall Hanging Rack, w/RL94

51.5 x 12.5 x 49.1

160

597,000

70 x 35 x 66

385

N/A

0.81

$8,100

TRW03HEXiN

3-Unit Wall Hanging Rack, w/RL94

51.5 x 12.5 x 49.1

160

576,000

70 x 35 x 66

385

N/A

0.81

$8,100

2018 SUGGESTED LIST PRICE (USD) • Page 7 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Tankless Rack Systems- Free-Standing (Condensing) TRS03ILWCU

The Tankless Rack System™ is designed to supply a packaged water heating solun as a fully-assembled system. The TRS includes pre-assembled water and gas connections and manifolds under the tankless water heaters that are properly sized to maintain optimum performance.

TRS02ILWCU

TRS23ILWCU

Rinnai Free-Standing Inline Wall Rack Systems Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRS02ILWCUeN

Exterior Inline Wall Mount Rack, 2 NG

47 x 19.3 x 58

208

398,000

70 x 35 x 66

410

0.97

N/A

$8,180

TRS02ILWCUeP

Exterior Inline Wall Mount Rack, 2 LP

47 x 19.3 x 58

208

398,000

70 x 35 x 66

410

0.97

N/A

$8,180

TRS02ILWCUiN

Interior Inline Wall Mount Rack, 2 NG

47 x 19.3 x 58

208

398,000

70 x 35 x 66

410

0.97

N/A

$8,180

TRS02ILWCUiP

Interior Inline Wall Mount Rack, 2 LP

47 x 19.3 x 58

208

398,000

70 x 35 x 66

410

0.97

N/A

$8,180

TRS23ILWCUeN

2-Unit Exterior Wall Standing Rack NG

65 x 19.3 x 58

222

398,000

70 x 35 x 66

424

0.97

N/A

$8,180

TRS23ILWCUeP

2-Unit Exterior Wall Standing Rack LP

65 x 19.3 x 58

222

398,000

70 x 35 x 66

424

0.97

N/A

$8,180

TRS23ILWCUiN

2-Unit Interior Wall Standing Rack NG

65 x 19.3 x 58

222

398,000

70 x 35 x 66

424

0.97

N/A

$8,180

TRS23ILWCUiP

2-Unit Interior Wall Standing Rack LP

65 x 19.3 x 58

222

398,000

70 x 35 x 66

424

0.97

N/A

$8,180

TRS03ILWCUeN

Exterior Inline Wall Mount Rack, 3 NG

65 x 19.3 x 58

297

597,000

70 x 35 x 66

497

0.97

N/A

$12,565

TRS03ILWCUeP

Exterior Inline Wall Mount Rack, 3 LP

65 x 19.3 x 58

297

597,000

70 x 35 x 66

497

0.97

N/A

$12,565

TRS03ILWCUiN

Interior Inline Wall Mount Rack, 3 NG

65 x 19.3 x 58

297

597,000

70 x 35 x 66

497

0.97

N/A

$12,565

TRS03ILWCUiP

Interior Inline Wall Mount Rack, 3 LP

65 x 19.3 x 58

297

597,000

70 x 35 x 66

497

0.97

N/A

$12,565

2018 SUGGESTED LIST PRICE (USD) • Page 8 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Tankless Rack Systems - Free-Standing (Condensing Cont’d) Rinnai Tankless Free-Standing Rack Systems Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRS02CUeN

Exterior Free Standing Rack, 2 unit NG

47 x 31.1 x 55.6

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS02CUeP

Exterior Free Standing Rack, 2 unit LPG

47 x 31.1 x 55.6

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS02CUiN

Interior Free Standing Rack, 2 unit NG

47 x 31.1 x 55.6

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS02CUiP

Interior Free Standing Rack, 2 unit LPG

47 x 31.1 x 55.6

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS03CUeN

Exterior Free Standing Rack, 3 unit NG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS03CUeP

Exterior Free Standing Rack, 3 unit LPG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS03CUiN

Interior Free Standing Rack, 3 unit NG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS03CUiP

Interior Free Standing Rack, 3 unit LPG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS36CUeN

3-Unit Exterior Free Standing Rack NG

65 x 31.1 x 58

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS36CUeP

3-Unit Exterior Free Standing Rack LP

65 x 31.1 x 58

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS36CUiN

3-Unit Interior Free Standing Rack NG

65 x 31.1 x 58

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS36CUiP

3-Unit Interior Free Standing Rack LP

65 x 31.1 x 58

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS04CUeN

Exterior Free Standing Rack, 4 unit NG

65 x 31.1 x 55.6

365

796,000

70 x 35 x 66

562

0.97

N/A

$15,310

TRS04CUeP

Exterior Free Standing Rack, 4 unit LPG

65 x 31.1 x 55.6

365

796,000

70 x 35 x 66

562

0.97

N/A

$15,310

TRS04CUiN

Interior Free Standing Rack, 4 unit NG

65 x 31.1 x 55.6

365

796,000

70 x 35 x 66

562

0.97

N/A

$15,310

TRS04CUiP

Interior Free Standing Rack, 4 unit LPG

65 x 31.1 x 55.6

365

796,000

70 x 35 x 66

562

0.97

N/A

$15,310

TRS46CUeN

4-Unit Exterior Free Standing Rack NG

65 x 31.1 x 58

386

796,000

70 x 35 x 66

586

0.97

N/A

$15,310

TRS46CUeP

4-Unit Exterior Free Standing Rack LP

65 x 31.1 x 58

386

796,000

70 x 35 x 66

586

0.97

N/A

$15,310

TRS46CUiN

4-Unit Interior Free Standing Rack NG

65 x 31.1 x 58

386

796,000

70 x 35 x 66

586

0.97

N/A

$15,310

TRS46CUiP

4-Unit Interior Free Standing Rack LP

65 x 31.1 x 58

386

796,000

70 x 35 x 66

586

0.97

N/A

$15,310

Model Number

2018 SUGGESTED LIST PRICE (USD) • Page 9 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Tankless Rack Systems- Free-Standing (Condensing Cont’d) Rinnai Tankless Free-Standing Rack Systems Model Number

Product Description

Product Dimensions Inches (W x H x D)

Product Weight (lbs)

Max Heating Input (Btu/h)

Shipping Dimensions Inches (W x H x D)

Shipping Weight (lbs)

Thermal Efficiency

Uniform Energy Factor

List Price (U.S.)

TRS05CUeN

Exterior Free Standing Rack, 5 unit NG

65 x 31.1 x 55.6

462

995,000

70 x 35 x 66

658

0.97

N/A

$19,165

TRS05CUeP

Exterior Free Standing Rack, 5 unit LPG

65 x 31.1 x 55.6

462

995,000

70 x 35 x 66

658

0.97

N/A

$19,165

TRS05CUiN

Interior Free Standing Rack, 5 unit NG

65 x 31.1 x 55.6

462

995,000

70 x 35 x 66

658

0.97

N/A

$19,165

TRS05CUiP

Interior Free Standing Rack, 5 unit LPG

65 x 31.1 x 55.6

462

995,000

70 x 35 x 66

658

0.97

N/A

$19,165

TRS06CUeN

Exterior Free Standing Rack, 6 unit NG

65 x 31.1 x 55.6

538

1,194,000

70 x 35 x 66

731

0.97

N/A

$23,020

TRS06CUeP

Exterior Free Standing Rack, 6 unit LPG

65 x 31.1 x 55.6

538

1,194,000

70 x 35 x 66

731

0.97

N/A

$23,020

TRS06CUiN

Interior Free Standing Rack, 6 unit NG

65 x 31.1 x 55.6

538

1,194,000

70 x 35 x 66

731

0.97

N/A

$23,020

TRS06CUiP

Interior Free Standing Rack, 6 unit LPG

65 x 31.1 x 55.6

538

1,194,000

70 x 35 x 66

731

0.97

N/A

$23,020

Rinnai Tankless Free Standing Inline Rack Systems TRS02ILCUeN

Ext Inline Free Standing Rack, 2unit NG

47 x 31.1 x 55.6

212

398,000

70 x 35 x 66

414

0.97

N/A

$8,180

TRS02ILCUeP

Ext Inline Free Standing Rack, 2unit LPG

47 x 31.1 x 55.6

212

398,000

70 x 35 x 66

414

0.97

N/A

$8,180

TRS02ILCUiN

Int Inline Free Standing Rack, 2unit NG

47 x 31.1 x 55.6

212

398,000

70 x 35 x 66

414

0.97

N/A

$8,180

TRS02ILCUiP

Int Inline Free Standing Rack, 2unit LPG

47 x 31.1 x 55.6

212

398,000

70 x 35 x 66

414

0.97

N/A

$8,180

TRS23ILCUeN

2-Unit Exterior Free Standing Rack NG

65 x 19.3 x 58

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS23ILCUeP

2-Unit Exterior Free Standing Rack LP

65 x 19.3 x 58

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS23ILCUiN

2-Unit Interior Free Standing Rack NG

65 x 19.3 x 58

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS23ILCUiP

2-Unit Interior Free Standing Rack LP

65 x 19.3 x 58

214

398,000

70 x 35 x 66

416

0.97

N/A

$8,180

TRS03ILCUeN

Ext Inline Free Standing Rack, 3unit NG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS03ILCUeP

Ext Inline Free Standing Rack, 3unit LPG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS03ILCUiN

Int Inline Free Standing Rack, 3unit NG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

TRS03ILCUiP

Int Inline Free Standing Rack, 3unit LPG

65 x 31.1 x 55.6

290

597,000

70 x 35 x 66

490

0.97

N/A

$12,565

2018 SUGGESTED LIST PRICE (USD) • Page 10 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Common Vent 3” Common Vent Model Number

Product Description

List Price (U.S.)

790130

3” Kit Direct Vent for Corner Rack and In-line

$170

790131

3” Kit Room air for Corner Rack and In-line

$100

790120

Elbow 3” 45 (2x)

$12

790121

Elbow 3” 90

$9

790122

Extension 3”-39”

$12

790123

Bracket 3” metal

$5

790124

Wall terminal 3” plastic

$20

790125

Roof terminal 3” plastic

$46

Model Number

Product Description

List Price (U.S.)

790132

4” Common vent starter kit DV

$105

790134

4” Common vent in-line 6” DV

$140

790137

4” Common vent starter kit room air

$75

4’’ Common Vent

790142

4’’ Common Vent B2B DV Add on Kits

$240

790143

4’’ Common Vent B2B room air add on kits

$160

790139

4” Common vent in-line room air

$95

790026

Elbow 4” 45 (2x)

$16

790027

Elbow 4” 90

$9

790028

Extension 4”-39”

$14

790088

Extension 4”-78”

$21

790091

Bracket 4” metal

$5

790093

Wall terminal 4” plastic

$44

790095

Roof terminal 4” plastic

$127

790097

Rain cap flue terminal 4”

$28

780060

Rain cap air terminal 4”

$22

790099

4” and 6” flashing 25-45 shingle + Spec. adapter

$42

790101

4” and 6” flat roof flashing

$27

790102

4” extension roof terminal kit plastic

$57

2018 SUGGESTED LIST PRICE (USD) • Page 11 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Common Vent (Cont’d) 6’’ Common Vent Model Number

Product Description

List Price (U.S.)

790133

6” Common vent starter kit DV

$115

790135

6” Common vent in-line 6” DV

$155

790136

6” Common vent B2B 6” DV

$275

790138

6” Common vent starter kit 6” room air

$80

790140

6” Common vent in-line 6” room air

$105

790141

6” Common vent B2B 6” room air

$190

790086

Elbow 6”-45 (2x)

$35

790087

Elbow 6”-87

$18

790089

Extension 6”-39”

$26

790090

Extension 6”-78”

$52

790092

Bracket 6” metal

$5

790094

Wall terminal 6” plastic

$53

790096

Roof terminal 6” plastic

$135

790098

Rain cap flue terminal 6”

$32

780061

Rain cap air terminal 6”

$24

790103

6” extension roof terminal kit metal

$100

790099

4” and 6” flashing 25-45 shingle + Spec. adapter

$42

790101

4” and 6” flashing flat roof

$27

2018 SUGGESTED LIST PRICE (USD) • Page 12 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Commercial Accessories Model Number

Product Description

List Price (U.S.)

107000376

Grundfos UPS 26-99 (S)F Circulation Pump

$530

107000377

Grundfos UPS 26-150 (S)F Circulation Pump

$630

107000378

Grundfos UPS40-160 FB Circulation Pump

$2,400

109000733

TACO 265-3 Digital Timer Controller

$225

109000734

Honeywell L6006C Aquastat Controller

$205

109000735

Honeywell L6006A Aquastat Controller

$225

109000736

1’’ NC Solenoid

$250

109000737

1-1/2’’ NC Solenoid

$650

105000195

Freeze Protection Surge Protector kit KT

$400

MCC-91-2W

Commercial Controller (additional)

$120

REU-EZC-2

EZConnect® Cable for connecting 2 units

$45

REU-CSA-C1

Cascade Harness: 3m

$35

REU-CSA-C2

Cascade Harness: 8m

$65

REU-OPU3

BMS/Air Handler

$45

103000038

ScaleCutter® System 3/4” Feed

$210

103000039

ScaleCutter® System Refill

$110

103000067

Commercial Neutralization Tank w/ Media

$400

103000068

Commercial Neutralization Replacement Media (40 lbs)

$100

PCD07-IB

Pipe Cover (Commercial)

$128

PCD07-IB-BP

Pipe Cover bottom plate (Commercial)

$50

RGB-CTWH-4

Recess Box

$405

RWM101

Control-R™ Wireless Module

$125

RWMPB01

Control-R™ Push Button

$50

RWMMS01

Control-R™ Motion Sensor

$200

RWMKT01

Control-R™ Wireless Demand Recirc w/ Push Button

$175

RWMKT01P

Control-R™ Wireless Demand Recirc w/ Pump and Push Button

$525

RWMKT03

Control-R™ Wireless Demand Recirc w/ Push Button and Temperature Sensor

$400

RWMKT03P

Control-R™ Wireless Demand Recirc w/ Pump, Push Button and Temperature Sensor

$750

ST119

Gray 119 Gallon Storage Tank

$2,400

2018 SUGGESTED LIST PRICE (USD) • Page 13 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER Installation Type

Internal (Indoor) Commercial Applications

Model Numbers

CU199i (REU-N3237FFC-US) CU160i (REU-N2530FFC-US)

Approved Gas Types

Natural and Propane

Thermal Efficiency

Up to 97%

Uniform Energy Factor (UEF)

0.93

Energy Factor (EF) (Canada)

CU199i: CU160i:

High Altitude Approved

Up to 10,200 ft (3,109 m) Water Flow Sensor, Electronic Water Control and Bypass Control Standard: Integrated Controller Optional: MC-91-2US

Water Flow Control Controller Certifications

Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Vent lengths up to 150 ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths:

Vent Lengths

2 in. (51 mm)

3 in. (76 mm)

65 ft (20 m)

150 ft (46 m)

Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Included with Purchase Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2), and Self-Tapping Screws (x2) Additional Features • Complies with South Coast • Ultra Low NOx Air Quality Management District 14 ng/J or 20 ppm • Tankless Rack System™ Compatible • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels

Concentric

• • • •

Vent Sizes

2 in. X 4 in.

3 in. X 5 in.

Vent Lengths

65 ft (20 m)

150 ft (46 m)

AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®

Warranty • Heat Exchanger: 8 years or 12,000 operation hours, whichever occurs first • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year

• • • •

Twin Pipe Vent Sizes

0.96 0.95

Commercial Tankless Rack Systems

Compact Design to Save Space Wi-Fi Technology for Remote Monitoring and Management Sliding Mounting Bracket for Easy Installation Simple Gas Conversion

Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Cascade Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

Demand Duo™ Commercial Hybrid System


in. (mm)

Electrical

SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level

CU199i CU160i 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm)

FRONT

15,000 199,000

160,000

0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 64 lb (29 kg) 49 dB

0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 62 lb (28 kg) 48 dB

Normal Standby

84 W

52 W 1.3 W

Freeze Protection Max Current

148 W 4 Amps

Fuse

10 Amps

• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default

Temperature

185° F (85° C) With Parameter Adjustment

SIDE

By-Pass Flow Control

Electronic

Gas Supply Pressure2

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Vent Connection:

Ignition System

Direct Electronic Ignition

2 in. (51 mm)

• • • •

Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)

nominal PVC/

• • • • • • •

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT

Electronic Connections

Polypropylene or

Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)

Water Supply Pressure Controller Cable Service Connections

Clearances

Top: 2 in. (51 mm)* Bottom/Ground: 12 in. (305 mm) Front: 0 in.**

3 in./5 in. Concentric.

• Back: 0 in. • Sides: 2 in. (51 mm)*** • Vent: 0 in.

* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box

BOTTOM

1

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.

Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.

Connection COLD HOT GAS 0

25

50

75

100

125

150

PRV

F C H B E D G A

in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193


SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER

• • • •

Installation Type

External (Outdoor) Commercial Applications

Model Numbers

CU199e (REU-N3237WC-US) CU160e (REU-N2530WC-US)

Approved Gas Types

Natural and Propane

Thermal Efficiency

Up to 97%

Uniform Energy Factor (UEF)

0.93

Energy Factor (EF) (Canada)

0.96

High Altitude Approved

Up to 10,200 ft (3,109 m)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Bypass Control

Controller

Standard: Integrated Controller Optional: MC-91-2US

Certifications

AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®

Warranty

Compact Design to Save Space

• Heat Exchanger: 8 years or 12,000 operation hours, whichever

Wi-Fi Technology for Remote Monitoring and Management

occurs first

Simple Gas Conversion

• All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year

Electronically Connect up to 24 Water Heaters to Operate as One Hot Water Source

Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection

Condensate Neutralizer, ScaleCutter, Drain Down Kit, Additional Controllers, Recess Box, Pipe Cover, Recirculation Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

Included with Purchase

• • • • •

Commercial Tankless Rack Systems

Tankless Water Heater Pressure Relief Valve and Adapter Isolation Valve Kit Integrated Controller Recirculation Pump Cable

Additional Features

• Fully-assembled, comprehensive water heating solutions

• Numerous configurations: Free

• Complies with South Coast • Ultra Low NOx Air Quality Management • Tankless Rack System™ Compatible District 14 ng/J or 20 ppm • 1/2 in. (13 mm) Gas Line Compatible NOx Emission Levels

Standing, Inline Free Standing, Inline Wall Mount, Wall Hanging, and Corner

• Made to Order Customized Solutions

● JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


in. (mm)

Electrical

SPECIFICATION Dimensions - w, h, d Minimum Gas Consumption Btu/h Maximum Gas Consumption Btu/h Flow Rate1 (Min - Max) Max Flow Rate with Parameter Adjustment Weight Sound Level

FRONT

CU199e CU160e 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) 15,000

Normal Standby

199,000

160,000

0.26 - 9.8 GPM (1.0 - 37 L/min) 11 GPM (42 L/min) 64 lb (29 kg) 53 dB

0.26 - 8.0 GPM (1.0 - 30 L/min) 9 GPM (34 L/min) 62 lb (28 kg) 52 dB

81 W

49 W 1.3 W

Freeze Protection Max Current

152 W 4 Amps

Fuse

10 Amps

Temperature

• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default

By-Pass Flow Control

Electronic

Gas Supply Pressure2

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

185° F (85° C) With Parameter Adjustment SIDE

• • • •

Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)

Service Connections

• • • •

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT

Clearances

• Top: 2 in. (51 mm)* • Back: 0 in. • Bottom/Ground: 12 in. (305 mm) • Sides: 2 in. (51 mm)*** • Front: 0 in.** • Front Exhaust: 24 in. (610 mm)

Electronic Connections Water Supply Pressure Controller Cable

Minimum: 50 PSI (Recommended 60-80 PSI for max performance) Maximum: 150 PSI Non-Polarized Two Core Cable (Minimum 22 AWG)

* 0 in. from vent components ** Clearance for servicing is 24 in. (610 mm) in front of water heater *** Add 0.25 in. (6.35 mm) for recess box

BOTTOM

1

Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.

Flow curves apply only to incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures greater than 70° F (21° C), please contact Rinnai. NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.

Connection COLD HOT GAS 0

25

50

75

100

125

150

PRV

F C H B E D G A

in. mm 9.54 242 3.56 90 14.27 362 6.16 156 3.57 91 2.78 71 10.39 264 7.60 193


Demand Duo™ 80 Hybrid Water Heating System Direct Vent Options

• Concentric: Ubbink Concentric Non-Condensing Vent Clearances from Combustibles (RL94iRLX94i)

• Top of heater - 6 in. (152mm)* • Front of heater - 6 in. (152mm)** • Sides of heater - 2 in. (51mm)

• Back of heater - 0 in. • Bottom of heater - 12 in. (305mm) • From vent pipe - 0 in.

Clearances from Non-Combustibles (RL94i/RLX94i)

• Top of heater - 2 in. (51mm)* • Front of heater - 6 in. (152mm)** • Sides of heater - 1/2 in. (13mm)

• Back of heater - 0 in. • Bottom of heater - 12 in. (305mm) • From vent pipe - 0 in.

*54 in. (1371.6mm) required for anode rod serviceability **24 in. (610mm) required for serviceability Safety Features

• • • •

• Remaining flame (OHS) • Thermal fuse • Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Storage Tank

• Pre-installed temperature & pressure relief valve • 2 in. Foam insulation • Brass drain valve • Glass-lined inner tank • 1.5 in. MNPT dielectric hot and cold • Dual magnesium anode rods connections • Hand hole clean-out Limited Warranty

• • • •

Maximum Gas Consumption: 199,000 BTU/h Temperature Range F (C):

• •

Commercial: 98°- 185° (37°- 85°)

• •

RL94i: 259 Gallons (980 L)

Heat Exchanger: Residential - 12 years* / Commercial - 5 years* Tank: 6 years* All Other Parts: 5 years*

Labor: 1 year* (*Reference Tankless Water Heater manual for further warranty information.)

Residential: 98°- 140° (37°- 60°) Tank Capacity: 80 Gallons (303 L) First Hour Delivery (100°F Rise): RLX94i: 251 Gallons (950L)

Front

DIMENSIONS

Side

HOT OUTLET

Top 1-1/2” MNPT (HOT)

27.74 Ø 24.25 12.13 HOT

56.83

28.64 30.00°

Dual Anodes

62.69

54.28 T&P

64.71

29.29 (GAS)

24.53 PRV

4.19 COLD

1-1/2” MNPT (COLD)

3.54 DRAIN

WEIGHT: 290 lb (132 kg) © 2017 Rinnai America Corporation

28.66 (GAS) 34.05

COLD INLET

Demand Duo 80-SP

11/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Demand Duo™ 80 Hybrid Water Heating System Product Number

CHS19980HEiP

Product Description

CHS19980HEXiN

Hybrid System: Non-condensing tankless, Insulated Storage Tank, Pump & Control 10,300 (3.0) 199,000 (58.3) 192,000 (56.3) 80 Gallons (303 Liters) 0.81 259 Gallons 251 Gallons (980 Liters) (950 Liters) 98° F (37° C) to 185° F (85° C) 290 lb (132 kg) 49 dB 278 W 44 W

Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h) Tank Volume Uniform Energy Factor (RL94i) First Hour Delivery Temperature Setting Product Weight Noise level

System Electrical Data

CHS19980HEiN

Normal Standby Anti-frost Protection Max Current Fuse

300 W 5.5 A Tankless Engine - 10 A, System Controller - 10 A Electronic 8.0 - 13.5 inch W.C. 4.0 - 10.5 inch W.C. 4.0 - 10.5 inch W.C.

By-Pass Control Gas Supply Pressure

Gas Supply Inlet - 3/4 in. MNPT Hot Water Outlet - 1-1/2 in. MNPT Cold Water Inlet - 1-1/2 in. MNPT

Connections Ignition System

Direct Electronic Ignition Appliance: AC 120 Volts, 60Hz. Integrated Temperature Controller: DC 12 Volts (Digital)

Electric Connections Water Temperature Control

Simulation Feed forward and Feedback

Maximum Water Supply Pressure

150 PSI

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels (RL94i)

Yes

No

Yes

RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED Tank Capacity

CHS19980HE

CHS19980HEX

°F

30°F 40°F

50°F

60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F

°C

17°C 22°C

28°C

33°C 39°C 44°C 50°C

56°C

61°C

67°C

72°C

78°C

507

405

338

253

225

203

184

169

156

145

303 Liters LPH 2557 1917

1534

1278 1096 959

852

767

697

639

590

548

489

391

326

244

217

195

178

163

150

140

303 Liters LPH 2467 1850

1480

1233 1057 925

822

740

673

617

569

529

80 U.S. Gals.

80 U.S. Gals.

GPH 675

GPH 652

289

279

RL94 Tankless Water Heater maintains the following certifications:

© 2017 Rinnai America Corporation

Demand Duo 80-SP-1

C

US

Low Lead Content NSF/ANSI 372

11/2017

SANITATION


Demand Duo™ 80 Hybrid Water Heating System Product Number

RHS19980HEiP

Product Description Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h) Tank Volume Uniform Energy Factor (RL94i) First Hour Delivery Temperature Setting Product Weight Noise level

System Electrical Data

Normal Standby Anti-frost Protection Max Current Fuse

By-Pass Control Gas Supply Pressure

RHS19980HEiN

RHS19980HEXiN

Hybrid System: Non-condensing tankless, Insulated Storage Tank, Pump & Control 10,300 (3.0) 199,000 (58.3) 192,000 (56.3) 80 Gallons (303 Liters) 0.81 259 Gallons 251 Gallons (980 Liters) (950 Liters) 98° F (37° C) to 140° F (60° C) 290 lb (132 kg) 49 dB 278 W 44 W 300 W 5.5 A Tankless Engine - 10 A, System Controller - 10 A Electronic 8.0 - 13.5 inch W.C. 4.0 - 10.5 inch W.C. 4.0 - 10.5 inch W.C. Gas Supply Inlet - 3/4 in. MNPT Hot Water Outlet - 1-1/2 in. MNPT Cold Water Inlet - 1-1/2 in. MNPT

Connections Ignition System

Direct Electronic Ignition Appliance: AC 120 Volts, 60Hz. Integrated Temperature Controller: DC 12 Volts (Digital)

Electric Connections Water Temperature Control

Simulation Feed forward and Feedback

Maximum Water Supply Pressure

150 PSI

Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels (RL94i)

Yes

No

Yes

RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED Tank Capacity

CHS19980HE

CHS19980HEX

80 U.S. Gals.

°F

30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F

°C

17°C 22°C 28°C 33°C 39°C 44°C 50°C

56°C

61°C

67°C

72°C

78°C

675

289

253

225

203

184

169

156

145

303 Liters LPH 2557 1917 1534 1278 1096

959

852

767

697

639

590

548

279

244

217

195

178

163

150

140

303 Liters LPH 2467 1850 1480 1233 1057

925

822

740

673

617

569

529

80 U.S. Gals.

GPH

GPH

652

507

489

405

391

338

326

RL94 Tankless Water Heater maintains the following certifications:

© 2017 Rinnai America Corporation

Demand Duo 80-SP-1

C

US

Low Lead Content NSF/ANSI 372

SANITATION

11/2017

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


SUPER-HIGH-EFFICIENCY (CONDENSING) HYBRID WATER HEATING SYSTEM

Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Vent lengths up to 150 ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths:

Vent Lengths

2 in. (51 mm)

3 in. (76 mm)

65 ft (20 m)

150 ft (46 m)

2 in. X 4 in.

3 in. X 5 in.

Vent Lengths

65 ft (20 m)

150 ft (46 m)

Model Numbers

RHS199100SE

Approved Gas Types

Natural and Propane

Maximum Gas Consumption

199,000 Btu/h (58.3 kW/h)

Uniform Energy Factor (UEF)

RU199i: 0.93

Energy Factor (EF) (For Canada)

RU199i: 0.96

First Hour Delivery (100°F Rise)

315 Gallons (1,192 L)

High Altitude Approved

Up to 10,200 Ft (3,109 M)

Tank Capacity

119 Gallons (450 L)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Bypass Control

Controller

Standard: Integrated Controller Optional: MC-91-2US

Certifications

AHRI, ANSI Z21.10.3, CSA 4.3, and Energy Star®

Warranty • Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first • Tank: 6 years • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year (Refer to the Installation and Operation Manual for further warranty information.) Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection

Concentric Vent Sizes

Internal (Indoor) Residential Applications

Storage Tank • 2 in. (51 mm) Eco-friendly foam insulation • Glass-lined inner tank • 1-1/2 in. (38 mm) MNPT dielectric hot and cold connections • Pre-installed temperature and pressure relief valve • Brass drain valve • Dual magnesium anode rods • Hand hole clean-out

• • • •

Twin Pipe Vent Sizes

Installation Type

Additional Features • Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels

Condensate Neutralizer, ScaleCutter, Control-R™ Wi-Fi Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

• Ultra Low NOx • 1/2 in. (13 mm) Gas Line Compatible

• Wi-Fi Technology for Remote Monitoring and Management (with Control-R™ Wi-Fi Module accessory)

• Simple Gas Conversion

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


INCHES SPECIFICATION

Condensing Hybrid System: Condensing Tankless Water Heater, Insulated Storage Tank, Pump and Control

Product Description Minimum Gas Consumption Btu/h (kW/h)

15,000 (4.5)

Maximum Gas Consumption Btu/h (kW/h)

199,000 (58.3)

Tank Volume

119 Gallons (450 Liters)

Weight

431 lb (195 kg)

Sound Level

Electrical

TOP

RHS199100SE

49 dB

Normal

265 W

Standby

44 W

Freeze Protection

148 W

Max Current

FRONT

5.5 Amps

Fuse

Tankless Engine: 10 Amps, System Controller 10 Amps

• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default

Temperature

185° F (85° C) With Parameter Adjustment

By-Pass Flow Control

Electronic

Gas Supply Pressure

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

Electronic Connections

• Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital)

Water Supply Pressure

• Maximum: 150 PSI

Service Connections

• • • •

Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 1-1/2 in. (38 mm) NPT Hot Water Outlet: 1-1/2 in. (38 mm) NPT Condensate Drain: 1/2 in. (13 mm) (SOCKET)

T&P - Temperature and Pressure relief valve

RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED

Tank Capacity

°F

30°F

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

140°F

°C

17°C

22°C

28°C

33°C

39°C

44°C

50°C

56°C

61°C

67°C

72°C

78°C

119 U.S. Gals.

GPH

772

579

463

386

331

289

257

232

211

193

178

165

450 Liters

LPH

2922

2192

1753

1461

1253

1093

973

878

799

731

673

625


Demand Duo™ Commercial Hybrid Water Heating System Direct Vent Options

 Concentric: Ubbink Polypropylene Concentric Vent  Twin Pipe: PVC / CPVC (3” and 4” Configurations), or Centrotherm 3” Polypropylene (with Centrotherm Twin Pipe Adaptor)

 Common Vent Solutions  Room Air: PVC or PP 3” or 4 “ (VERTICAL TERMINATIONS ONLY) -Flue check valve for room air included with system. Clearances from Combustibles (C199i)

 Top of heater - 6 in (152mm)*  Front of heater - 6 in (152mm)**  Sides of heater - 2 in (51mm)

 Back of heater - 0 in  Bottom of heater - 12 in (305mm)  From vent pipe - 0 in

Clearances from Non-Combustibles (C199i)

 Top of heater - 2 in (51mm)*  Front of heater - 6 in (152mm)**  Sides of heater - 1/2 in (13mm)

 Back of heater - 0 in  Bottom of heater - 12 in (305mm)  From vent pipe - 0 in

*54 in (1371.6mm) required for anode rod serviceability **24 in (610mm) required for serviceability Safety Features

   

 Remaining flame (OHS)  Thermal fuse  Automatic frost protection

Flame failure - Flame Rod Boiling protection Combustion fan rpm check Over current - glass fuse

Storage Tank

 2” Eco-friendly foam insulation  Glass-lined inner tank  2” MNPT dielectric hot and cold

Maximum Gas Consumption: 199,000 BTU/h

connections

Pre-installed temperature & pressure relief valve Brass drain valve Dual magnesium anode rods Hand hole clean-out

Commercial Limited Warranty

Thermal Efficiency: 96% (C199i) Temperature Range F (C): 98°- 185° (37°- 85°) Tank Capacity: 119 Gallons (450 L) First Hour Delivery (100°F Rise): 315 Gallons (1192 L)

DIMENSIONS

   

Front

   

Heat Exchanger: 6 years* Tank: 6 years* All Other Parts: 5 years*

Labor: 1 year* (*Reference Tankless Water Heater manual for further warranty information.) HOT OUTLET

Side

Top

Dual Anodes

WEIGHT: 428 lb (194 kg) COLD INLET

© 2015 Rinnai Corporation

CHS199100-SP

10/2015

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Demand Duo™ Commercial Hybrid Water Heating System Product Number

CHS199100 Condensing Hybrid System: Condensing tankless, Insulated Storage Tank, Pump & Control

Product Description Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h)

15,200 (4.5) 199,000 (58.3) 119 Gallons (450 Liters) 96% 315 Gallons (1192 Liters) 98° F (37° C) to 185° F (85° C) 428 lb (194 kg) 52 dB 256 W 44 W 326 W 5.5 A Tankless Engine - 10 A, System Controller - 10 A

Tank Volume Thermal Efficiency (C199i) First Hour Delivery Temperature Setting Product Weight Noise level Normal Standby Anti-frost Protection Max Current Fuse

System Electrical Data

By-Pass Control

Electronic Natural Gas Propane

Gas Supply Pressure

4.0 - 10.5 inch W.C. 8.0 - 13.5 inch W.C. Gas Supply Inlet - 3/4" MNPT Hot Water Outlet - 2" MNPT Cold Water Inlet - 2" MNPT

Connections Ignition System

Direct Electronic Ignition Appliance: AC 120 Volts, 60Hz. Integrated Temperature Controller: DC 12 Volts (Digital)

Electric Connections Water Temperature Control

Simulation Feed forward and Feedback

Maximum Water Supply Pressure

150 PSI Yes

Commercial Energy Star Certified (C199i) Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx emission levels (C199i)

Yes

RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED

Tank Capacity

°F

30°F

40°F

°C

17°C 22°C 28°C 579

50°F 463

60°F 70°F 80°F 90°F

100°F

33°C 39°C 44°C 50°C 56°C 386

331

110°F 120°F 130°F 140°F 61°C

67°C

72°C

78°C

119 U.S. Gals.

GPH

772

289

257

232

211

193

178

165

450 Liters

LPH

2922 2192 1753 1461 1253 1093

973

878

799

731

673

625

C199i Tankless Water Heater maintains the following certifications: C

US

Low Lead Content NSF/ANSI 372

SANITATION


SUPER-HIGH-EFFICIENCY (CONDENSING) HYBRID WATER HEATING SYSTEM Installation Type

Internal (Indoor) Commercial Applications

Model Numbers

CHS199100CU

Approved Gas Types

Natural and Propane

Maximum Gas Consumption

199,000 BTU/h

Thermal Efficiency

Up to 97%

First Hour Delivery (100°F Rise)

315 Gallons (1192 L)

High Altitude Approved

Up to 10,200 Ft (3,109 M)

Tank Capacity

119 Gallons (450 L)

Water Flow Control

Water Flow Sensor, Electronic Water Control and Bypass Control

Controller

Standard: Integrated Controller Optional: MC-91-2US

Certifications

AHRI, ANSI Z21.10.3, CSA 4.3, and Energy Star®

Storage Tank • 2” Eco-friendly foam insulation • Glass-lined inner tank • 1-1/2” MNPT dielectric hot and cold connections • Pre-installed temperature & Pressure relief valve • Brass drain valve • Dual magnesium anode rods • Hand hole clean-out

• • • •

Concentric or Schedule 40 PVC/CPVC Direct Vent (Concentric and Twin Pipe) Non-Direct Vent (Room Air) Common Vent (Direct Vent and Room Air) Vent lengths up to 150 Ft with eight Tankless Water Heater units. • Maximum Equivalent Vent Lengths: Twin Pipe Vent Sizes Vent Lengths

2 in. (51 mm)

3 in. (76 mm)

65 ft (20 m)

150 ft (46 m)

Warranty • Heat Exchanger: 8 years or 12,000 operation hours, whichever occurs first • Tank: 6 years • All Other Parts and Components: 5 Years • Reasonable Labor: 1 Year (Refer to the Installation and Operation Manual for further warranty information.) Safety Devices Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection Additional Features • Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels

Concentric Vent Sizes

2 in. X 4 in.

3 in. X 5 in.

Vent Lengths

65 ft (20 m)

150 ft (46 m)

• Ultra Low NOx • Tankless Rack System™ Compatible • 1/2 in. (13 mm) Gas Line Compatible

Room Air Screen, Condensate Neutralizer, ScaleCutter, ControlR™ WI-FI Module, Wireless Accessories, and many more. Visit rinnai.us for a complete list of accessories.

• Wi-Fi Technology for Remote Monitoring and Management • Simple Gas Conversion

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


INCHES SPECIFICATION

CHS199100CU Condensing Hybrid System: Condensing Tankless, Insulated Storage Tank, Pump & Control

Product Description Minimum Gas Consumption Btu/h (kW/h) Maximum Gas Consumption Btu/h (kW/h)

15,000 (4.5) 199,000 (58.3) 119 Gallons (450 Liters) Up to 97% 431 lb (195 kg) 49 dB

Tank Volume Thermal Efficiency (CU199i) Weight Sound Level

Electrical

TOP

Normal Standby

265 W 44 W

Freeze Protection Max Current

148 W 5.5 Amps

Fuse

Tankless Engine: 10 Amps, System Controller 10 Amps

• Minimum: 98° F (37° C) Default • Maximum: 140° F (60° C) Default

Temperature

185° F (85° C) With Parameter Adjustment

By-Pass Flow Control

Electronic

Gas Supply Pressure

• Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.

Ignition System

Direct Electronic Ignition

2

Electronic Connections Water Supply Pressure Service Connections

FRONT

• • • • • • •

Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital) Maximum: 150 PSI Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 1-1/2 in. ( mm) NPT Hot Water Outlet: 1-1/2 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) (SOCKET)

RECOVERY CAPACITIES U.S. GALLON/HR LITERS/HR AT TEMPERATURE RISE INDICATED

Tank Capacity

°F

30°F

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

140°F

°C

17°C

22°C

28°C

33°C

39°C

44°C

50°C

56°C

61°C

67°C

72°C

78°C

119 U.S. Gals.

GPH

772

579

463

386

331

289

257

232

211

193

178

165

450 Liters

LPH

2922

2192

1753

1461

1253

1093

973

878

799

731

673

625


rinnai.us

1-800-621-9419

SPECIFICATIONS

Tankless Rack System

Free-Standing Rack with Six Rinnai Tankless Water Heaters

For complete details on commercial water heating solutions and maintenance services call 866-383-0707 or email commercialservices@rinnai.us. Rinnai Tankless Rack System Specification Sheet JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

1


Configurations TRS configurations and part numbers are listed in the following tables.

WALL-HANGING RACKS CU Series Part No.* TRW02CUiN

Rack type

Configuration

Illustration

Configuration

Illustration

2-unit interior wall-hanging rack, NG

TRW02CUeN 2-unit exterior wall-hanging rack, NG TRW02CUiP

2-unit interior wall-hanging rack, LP

TRW02CUeP 2-unit exterior wall-hanging rack, LP TRW23CUiN

2-unit interior wall-hanging rack, NG

TRW23CUeN 2-unit exterior wall-hanging rack, NG TRW23CUiP

2-unit interior wall-hanging rack, LP

TRW23CUeP 2-unit exterior wall-hanging rack, LP TRW03CUiN

3-unit interior wall-hanging rack, NG

TRW03CUeN 3-unit exterior wall-hanging rack, NG TRW03CUiP

3-unit interior wall-hanging rack, LP

TRW03CUeP 3-unit exterior wall-hanging rack, LP

SE Series Part No.*

Rack type

TRW02SEiN

2-unit interior wall-hanging rack, NG RUC

TRW02SEeN

2-unit exterior wall-hanging rack, NG RUC

TRW02SEiP

2-unit interior wall-hanging rack, LP RUC

TRW02SEeP

2-unit exterior wall-hanging rack, LP RUC

SE+ Series Featuring ThermaCirc360â„¢ Part No.*

Rack type

TRW02STiN

2-unit interior wall-hanging rack, NG

TRW02STeN

2-unit exterior wall-hanging rack, NG

TRW02STiP

2-unit interior wall-hanging rack, LP

TRW02STeP

2-unit exterior wall-hanging rack, LP

TRW03STiN

3-unit interior wall-hanging rack, NG

TRW03STeN

3-unit exterior wall-hanging rack, NG

TRW03STiP

3-unit interior wall-hanging rack, LP

TRW03STeP

3-unit exterior wall-hanging rack, LP

Configuration

Illustration

* Part No. Legend: TR = Tankless Rack; W = Wall Hanging; S = Stand Alone; IL = Inline; ILW = Inline Wall Mount; 2/3/4/5/6 = Number of Water Heaters; i/e = Interior/Exterior; NG/LP = Natural Gas/Liquid Propane 2

Rinnai Tankless Rack System Specification Sheet


Wall Hanging Configurations (Continued)

HE+ Series Part No.*

Rack type

TRW02HEiN

2-unit interior wall-hanging rack, NG [1]

TRW02HEXiN

2-unit interior wall-hanging rack, NG [2]

TRW02HEeN

2-unit exterior wall-hanging rack, NG

TRW02HEiP

2-unit interior wall-hanging rack, LP

TRW02HEeP

2-unit exterior wall-hanging rack, LP

TRW03HEiN

3-unit interior wall-hanging rack, NG [1]

TRW03HEXiN

3-unit interior wall-hanging rack, NG [2]

TRW03HEeN

3-unit exterior wall-hanging rack, NG

TRW03HEiP

3-unit interior wall-hanging rack, LP

TRW03HEeP

3-unit exterior wall-hanging rack, LP

[1] [2]

Configuration

Illustration

For use with Rinnai RL94i Tankless Water Heaters. For use with Rinnai RLX94i Tankless Water Heaters.

WALL-MOUNT RACKS Part No.*

Rack type

TRS02ILWCUiN

Configuration

Illustration

2-unit interior wall-mount rack, NG

TRS02ILWCUeN 2-unit exterior wall-mount rack, NG TRS02ILWCUiP

2-unit interior wall-mount rack, LP

TRS02ILWCUeP 2-unit exterior wall-mount rack, LP TRS23ILWCUiN

2-unit interior wall-mount ount rack, NG

TRS23ILWCUeN 2-unit exterior wall-mount mount rack, NG TRS23ILWCUiP

2-unit interior wall-mount rack, LP

TRS23ILWCUeP 2-unit exterior wall-mount rack, LP TRS03ILWCUiN

3-unit interior wall-mount rack, NG

TRS03ILWCUeN 3-unit exterior wall-mount rack, NG TRS03ILWCUiP

3-unit interior wall-mount rack, LP

TRS03ILWCUeP 3-unit exterior wall-mount rack, LP

CORNER-HANGING RACKS Part No.*

Rack type

TRC02CUiN

2-unit interior corner-hanging rack, NG

TRC02CUiP

2-unit interior corner-hanging rack, LP

Configuration

Illustration

* Part No. Legend: TR = Tankless Rack; W = Wall Hanging; S = Stand Alone; IL = Inline; ILW = Inline Wall Mount; 2/3/4/5/6 = Number of Water Heaters; i/e = Interior/Exterior; NG/LP = Natural Gas/Liquid Propane Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

3


FREE-STANDING RACKS Part No.*

Rack type

Configuration

TRS02CUiN

2-unit interior free-standing rack, NG

TRS02CUeN

2-unit exterior free-standing rack, NG

TRS02CUiP

2-unit interior free-standing rack, LP

TRS02CUeP

2-unit exterior free-standing rack, LP

TRS02ILCUiN

2-unit INLINE interior free-standing rack, NG

TRS02ILCUeN

2-unit INLINE exterior free-standing rack, NG

TRS02ILCUiP

2-unit INLINE interior free-standing rack, LP

TRS02ILCUeP

2-unit INLINE exterior free-standing rack, LP

TRS23ILCUiN

2-unit INLINE interior free-standing rack, NG

TRS23ILCUeN

2-unit INLINE exterior free-standing rack, NG

TRS23ILCUiP

2-unit INLINE interior free-standing rack, LP

TRS23ILCUeP

2-unit INLINE exterior free-standing rack, LP

TRS03ILCUiN

3-unit INLINE interior free-standing rack, NG

TRS03ILCUeN

3-unit INLINE exterior free-standing rack, NG

TRS03ILCUiP

3-unit INLINE interior free-standing rack, LP

TRS03ILCUeP

3-unit INLINE exterior free-standing rack, LP

TRS03CUiN

3-unit interior free-standing rack, NG

TRS03CUeN

3-unit exterior free-standing rack, NG

TRS03CUiP

3-unit interior free-standing rack, LP

TRS03CUeP

3-unit exterior free-standing rack, LP

TRS36CUiN

3-unit interior free-standing rack, NG

TRS36CUeN

3-unit exterior free-standing rack, NG

TRS36CUiP

3-unit interior free-standing rack, LP

TRS36CUeP

3-unit exterior free-standing rack, LP

TRS04CUiN

4-unit interior free-standing rack, NG

TRS04CUeN

4-unit exterior free-standing rack, NG

TRS04CUiP

4-unit interior free-standing rack, LP

TRS04CUeP

4-unit exterior free-standing rack, LP

TRS46CUiN

4-unit interior free-standing rack, NG

TRS46CUeN

4-unit exterior free-standing rack, NG

TRS46CUiP

4-unit interior free-standing rack, LP

TRS46CUeP

4-unit exterior free-standing rack, LP

TRS05CUiN

5-unit interior free-standing rack, NG

TRS05CUeN

5-unit exterior free-standing rack, NG

TRS05CUiP

5-unit interior free-standing rack, LP

TRS05CUeP

5-unit exterior free-standing rack, LP

TRS06CUiN

6-unit interior free-standing rack, NG

TRS06CUeN

6-unit exterior free-standing rack, NG

TRS06CUiP

6-unit interior free-standing rack, LP

TRS06CUeP

6-unit exterior free-standing rack, LP

Illustration

Back to Back

* Part No. Legend: TR = Tankless Rack; W = Wall Hanging; S = Stand Alone; IL = Inline; ILW = Inline Wall Mount; 2/3/4/5/6 = Number of Water Heaters; i/e = Interior/Exterior; NG/LP = Natural Gas/Liquid Propane

4

Rinnai Tankless Rack System Specification Sheet


Specifications WALL-HANGING RACKS Available Configurations • 2-Units • 3-Units

CU Series

2-Unit Wa l l - H a n g i n g F r a m e LEFT

FRONT

BACK

7.58

BOTTOM Model

Configuration

Illustration

TRW02CU

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

5


CU Series 2-Unit Wall-Hanging Frame (Continued) Model Water Heater Model

TRW02CUi CU199i (NG/LP)

TRWCU02CUe CU199e (NG/LP)

Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs Rack Frame - Specifications Frame Material Frame Finish Color

66 x 70 x 35 170 380

169 379

14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray

16 Gauge Stainless Steel 1.5” Square Tube Stainless Stainless

Water & Gas Connections Hot Water Trunk Line Diameter

2"

Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type

2" Rigid Copper Rigid Copper 2" Pipe 1-1/4" 1-1/4” MNPT

Gas Trunk Line Material Gas Branch Line Material Electric Requirements Voltage

Sch 40 Steel PVC Over CSST AC 120 Volts—60 Hz

Maximum Current (Amperes)

8 BTU and Flow Rates for C199i, CU199e (NG/LP)

Number of Tankless Water Heaters

2

Flow rate @ 70°F rise (gpm)

10.8

Flow rate @ 100°F rise (gpm)

7.6

Minimum input rate (Btuh) Maximum input rate (Btuh)

15,200 398,000

TRW02CU

6

Rinnai Tankless Rack System Specification Sheet


WALL-HANGING RACKS → CU SERIES

CU Series

3-Unit Wa l l - H a n g i n g F r a m e

FRONT

LEFT

BACK

BOTTOM

Model

Configuration

Illustration

TRW03CU

TRW23CU

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

7


CU Series 3-Unit Wall-Hanging Frame (Continued) Model

TRW03CUi

Water Heater Model

TRW03CUe

TRW23CUi

CU199i (NG/LP) CU199e (NG/LP) 66 x 70 x 35 248 244 469 465

Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs

TRW23CUe

CU199i (NG/LP) CU199e (NG/LP) 66 x 70 x 35 186 183 407 402

Rack Frame - Specifications 14 Gauge Hot Rolled 16 Gauge Steel 1.5” Square Stainless Steel Tube 1.5” Square Tube

Frame Material Frame Finish Color

14 Gauge Hot Rolled Steel 1.5” Square Tube

16 Gauge Stainless Steel 1.5” Square Tube

Powder Coat

Stainless

Powder Coat

Stainless

Gray

Stainless

Gray

Stainless

Water & Gas Connections Hot Water Trunk Line Diameter

2"

Cold Water Trunk Line Diameter

2"

Hot Water Trunk Line Material

Rigid Copper

Cold Water Trunk Line Material

Rigid Copper

Water Trunk Connection Type

2" PIPE

Gas Trunk Line Diameter

1-1/4"

Gas Trunk Connection Type

1-1/4” MNPT

Gas Trunk Line Material

Sch 40 Steel

Gas Branch Line Material

PVC Over CSST

Electric Requirements Voltage

AC 120 Volts—60 Hz

Maximum Current (Amperes)

12

8

BTU and Flow Rates for CU199i, CU199e (NG/LP) Number of Tankless Water Heaters

3

2

Flow rate @ 70°F rise (gpm)

16.2

10.8

Flow rate @ 100°F rise (gpm)

11.4

7.6

Minimum input rate (Btuh)

15,200

15,200

Maximum input rate (Btuh)

597,000

398,000

TRW03CU

8

TRW23CU

Rinnai Tankless Rack System Specification Sheet


WALL-HANGING RACKS → SE SERIES

SE Series

2-Unit Wa l l - H a n g i n g F r a m e

LEFT

FRONT

BACK

36.00

BOTTOM Model

Configuration

Illustration

TRW02SE

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

9


SE Series 2-Unit Wall-Hanging Frame (Continued) Model Water Heater Model

TRW02SEi RU199i (NG/LP)

TRW02SEe RU199e (NG/LP)

Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs

66 X 70 X 35 170 391

169 390

14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray

16 Gauge Stainless Steel 1.5” Square Tube Stainless Stainless

Rack Frame - Specifications Frame Material Frame Finish Color Water & Gas Connections Hot Water Trunk Line Diameter

2"

Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type

2" Rigid Copper Rigid Copper 2" PIPE 1-1/4" 1-1/4” MNPT

Gas Trunk Line Material Gas Branch Line Material Electric Requirements Voltage

Sch 40 Steel PVC Over CSST AC 120 Volts—60 Hz

Maximum Current (Amperes)

8 BTU and Flow Rates for RU199i, RU199e (NG/LP)

Number of Tankless Water Heaters

2

Flow rate @ 70°F rise (gpm)

10.8

Flow rate @ 100°F rise (gpm)

7.6

Minimum input rate (Btuh) Maximum input rate (Btuh)

15,200 398,000

TRW02SE

10

Rinnai Tankless Rack System Specification Sheet


WALL-HANGING RACKS → SE+ SERIES FEATURING THERMACIRC360™

SE+ Series Featuring ThermaCirc360™

LEFT

2-Unit Wa l l - H a n g i n g F r a m e

FRONT

BACK

14.38 HOT (2”COPPER) 9.38 COLD (2”COPPER)

14.50 HOT (2”COPPER) 4.50 GAS(1-1/4”NPT)

9.50 COLD (2”COPPER) 4.63 GAS (1-1/4”NPT)

BOTTOM

Model

Configuration

Illustration

TRW02ST

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

11


SE+ Series Featuring ThermaCirc360™ 2-Unit Wall-Hanging Frame (Continued)

Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs

TRW02STi TRW02STe RUR199i AND RU199i (NG/LP) RUR199e AND RU199e (NG/LP) 66 X 70 X 35 178 177 399 398

Rack Frame - Specifications 14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray

Frame Material Frame Finish Color

16 Gauge Stainless Steel 1.5” Square Tube Stainless Stainless

Water & Gas Connections Hot Water Trunk Line Diameter

2"

Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type

2" Rigid Copper Rigid Copper 2" PIPE 1-1/4" 1-1/4” MNPT

Gas Trunk Line Material

Sch 40 Steel

Gas Branch Line Material Electric Requirements Voltage

PVC Over CSST AC 120 Volts—60 Hz

Maximum Current (Amperes)

8

BTU and Flow Rates for RUR199i, RUR199e, RU199i, RU199e (NG/LP) Number of Tankless Water Heaters

2

Flow rate @ 70°F rise (gpm)

10.8

Flow rate @ 100°F rise (gpm)

7.6

Minimum input rate (Btuh)

15,200

Maximum input rate (Btuh)

398,000

TRW02ST

12

Rinnai Tankless Rack System Specification Sheet


WALL-HANGING RACKS → SE+ SERIES FEATURING THERMACIRC360™

SE+ Series Featuring ThermaCirc360™

3-Unit Wa l l - H a n g i n g F r a m e

FRONT

LEFT

BACK

BOTTOM

Model

Configuration

Illustration

TRW03ST

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

13


SE+ Series Featuring ThermaCirc360™ 3-Unit Wall-Hanging Frame (Continued) Model

TRW03STi

Water Heater Model

TRW03STe

RUR199i AND RU199i (NG/LP)

Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs Rack Frame - Specifications Frame Material Frame Finish Color

RUR199e AND RU199e (NG/LP)

66 x 70 x 35 258 476

254 472

14 Gauge Hot Rolled Steel 1.5” Square Tube

16 Gauge Stainless Steel 1.5” Square Tube

Powder Coat

Stainless

Gray

Stainless

Water & Gas Connections Hot Water Trunk Line Diameter

2"

Cold Water Trunk Line Diameter

2"

Hot Water Trunk Line Material

Rigid Copper

Cold Water Trunk Line Material

Rigid Copper

Water Trunk Connection Type

2" PIPE

Gas Trunk Line Diameter

1-1/4"

Gas Trunk Connection Type

1-1/4” MNPT

Gas Trunk Line Material

Sch 40 Steel

Gas Branch Line Material

PVC Over CSST

Electric Requirements Voltage

AC 120 Volts—60 Hz

Maximum Current (Amperes)

12

BTU and Flow Rates for RUR199i, RUR199e, RU199i, RU199e (NG/LP) Number of Tankless Water Heaters

3

Flow rate @ 70°F rise (gpm)

16.2

Flow rate @ 100°F rise (gpm)

11.4

Minimum input rate (Btuh)

15,200

Maximum input rate (Btuh)

597,000

TRW03ST

14

Rinnai Tankless Rack System Specification Sheet


WALL-HANGING RACKS → HE SERIES

HE Series

2-Unit Wa l l - H a n g i n g F r a m e

FRONT

LEFT

BACK

38.50 30.50 5.65

15.00

49.10

11.50 HOT (2”COPPER) 7.50 COLD (2”COPPER) 3.25 GAS (1-1/4”NPT)

30.50

BOTTOM

Model

Configuration

Illustration

TRW02HE

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

15


HE Series 2-Unit Wall-Hanging Frame (Continued) Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs

TRW02HEi

TRW02HEXi

TRW02HEe

RL94i (NG/LP)

RLX94i (NG) 66 x 67 x 35 120 334

RL94e (NG/LP)

120 334

120 334

Rack Frame - Specifications Frame Material

14 Gauge Hot Rolled Steel 1.5” Square Tube

Frame Finish Color

16 Gauge Stainless Steel 1.5” Square Tube

Powder Coat

Stainless

Gray

Stainless

Water & Gas Connections Hot Water Trunk Line Diameter

1-1/2"

Cold Water Trunk Line Diameter

1-1/2"

Hot Water Trunk Line Material

Rigid Copper

Cold Water Trunk Line Material

Rigid Copper

Water Trunk Connection Type

1-1/2" PIPE

Gas Trunk Line Diameter

1-1/4"

Gas Trunk Connection Type

1-1/4” MNPT

Gas Trunk Line Material

Sch 40 Steel

Gas Branch Line Material

PVC Over CSST

Electric Requirements Voltage

AC 120 Volts—60 Hz

Maximum Current (Amperes)

8 BTU and Flow Rates for RL94i, RLX94i, RL94e (NG/LP)

Number of Tankless Water Heaters

2

2

2

Flow rate @ 70°F rise (gpm)

9.5

9

9.5

Flow rate @ 100°F rise (gpm)

6.6

6.3

6.6

Minimum input rate (Btuh)

10,300

10,300

10,300

Maximum input rate (Btuh)

398,000

384,000

398,000

TRW02HE / TRW02HEX

16

Rinnai Tankless Rack System Specification Sheet


WALL-HANGING RACKS → HE SERIES

HE Series

3-Unit Wa l l - H a n g i n g F r a m e FRONT

LEFT

BACK

BOTTOM

Model

Configuration

Illustration

TRW03HE

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

17


HE Series 3-Unit Wall-Hanging Frame (Continued)

Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs

TRW03HEi

TRW03HEXi

TRW03HEe

RL94i (NG/LP)

RLX94i (NG) 66 x 67 x 35 160 374

RL94e (NG/LP)

160 374

160 374

Rack Frame - Specifications Frame Material

14 Gauge Hot Rolled Steel 1.5” Square Tube

16 Gauge Stainless Steel 1.5” Square Tube

Powder Coat

Stainless

Gray

Stainless

Frame Finish Color Water & Gas Connections Hot Water Trunk Line Diameter

1-1/2"

Cold Water Trunk Line Diameter

1-1/2"

Hot Water Trunk Line Material

Rigid Copper

Cold Water Trunk Line Material

Rigid Copper

Water Trunk Connection Type

1-1/2" PIPE

Gas Trunk Line Diameter

1-1/4"

Gas Trunk Connection Type Gas Trunk Line Material

1-1/4” MNPT Sch 40 Steel

Gas Branch Line Material

PVC Over CSST

Electric Requirements Voltage

AC 120 Volts—60 Hz

Maximum Current (Amperes)

12 BTU and Flow Rates for RL94i, RLX94i, RL94e (NG/LP)

Number of Tankless Water Heaters

3

3

3

Flow rate @ 70°F rise (gpm)

14

13.5

14

Flow rate @ 100°F rise (gpm)

9.8

9.4

9.8

Minimum input rate (Btuh)

10,300

10,300

10,300

Maximum input rate (Btuh)

597,000

576,000

597,000

TRW03HE / TRW03HEX

18

Rinnai Tankless Rack System Specification Sheet


WALL-MOUNT RACKS Available Configurations • 2-Units • 3-Units

2-Unit Wa l l - M o u n t F r a m e LEFT

FRONT

BACK

47.00 20.50 5.91 TYP

BOTTOM

Model

Configuration

Illustration

TRS02ILWCU

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

19


2-Unit Wall-Mount Frame (Continued) Model

TRS02ILWCU CU199i, CU199e (NG/LP)

Water Heater Model Crate Dimensions (HxLxD) - in

66 x 70x 35

Weight - Fully Assembled - lbs

208

Weight - Shipping (total) - lbs Rack Frame - Specifications Frame Rail Type

410 Sheet Metal Aluminum (0.090 5052-H32)

Frame Material Frame Finish

Powder Coat

Color

Gray

Water & Gas Connections Hot Water Trunk Line Diameter Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type

2" 2" Rigid Copper Rigid Copper 2" PIPE 1-1/4" 1-1/4” MNPT

Gas Trunk Line Material

Sch 40 Steel

Gas Branch Line Material Electric Requirements

PVC Over CSST

Voltage

AC 120 Volts—60 Hz

Maximum Current (Amperes)

8 BTU and Flow Rates for CU199i, CU199e (NG/LP)

Number of Tankless Water Heaters

2

Flow rate @ 70°F rise (gpm)

10.8

Flow rate @ 100°F rise (gpm)

7.6

Minimum input rate (Btuh)

15,200

Maximum input rate (Btuh)

398,000

TRS02ILWCU

20

Rinnai Tankless Rack System Specification Sheet


3-Unit Wa l l - M o u n t F r a m e

FRONT

LEFT

BACK

BOTTOM

Model

Configuration

Illustration

TRS03ILWCU

TRS23ILWCU

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

21


3-Unit Wall-Mount Frame (Continued) Model

TRS03ILWCU

Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs Rack Frame - Specifications

TRS23ILWCU

CU199i, CU199e (NG/LP) 66 x 70 x 35 297

222

497

424

Frame Rail Type

Sheet Metal

Frame Material

Aluminum (0.090 5052-H32)

Frame Finish Color

Powder Coat Gray

Water, Gas, and Condensate Connections Hot Water Trunk Line Diameter

2"

Cold Water Trunk Line Diameter Hot Water Trunk Line Material

2" Rigid Copper

Cold Water Trunk Line Material

Rigid Copper

Water Trunk Connection Type Gas Trunk Line Diameter

2" PIPE 1-1/4"

Gas Trunk Connection Type

1-1/4” MNPT

Gas Trunk Line Material Gas Branch Line Material

Sch 40 Steel PVC Over CSST

Condensate Trunk Line Diameter

3/4”

N/A

Condensate Trunk Line Material

Sch–40 PVC

N/A

3/4” Pipe

N/A

Condensate Trunk Connection Type Electric Requirements Prewired Electrical Assembly Voltage

Yes (Indoor Models Only) AC 120 Volts—60 Hz

Maximum Current (Amperes)

12

N/A 8

BTU and Flow Rates for CU199i, CU199e (NG/LP)

Number of Tankless Water Heaters

3

2

Flow rate @ 70°F rise (gpm)

16.2

10.8

Flow rate @ 100°F rise (gpm)

11.4

7.6

Minimum input rate (Btuh)

15,200

15,200

Maximum input rate (Btuh)

597,000

398,000

TRS03ILWCU

22

TRS23ILWCU

Rinnai Tankless Rack System Specification Sheet


CORNER-HANGING RACKS Available Configurations • 2-Units

2-Unit Corner-Hanging Frame TOP

FRONT

Model

Configuration

Illustration

TRC02CU

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

23


2-Unit Corner-Hanging Frame (Continued)

Model Water Heater Model Crate Dimensions (HxLxD) - in Weight - Fully Assembled - lbs Weight - Shipping (total) - lbs

TRC02CUi CU199i (NG/LP) 31.5 x 48 x 50 224 356

Rack Frame - Specifications Frame Material Frame Finish Color

14 Gauge Hot Rolled Steel 1.5” Square Tube Powder Coat Gray

Water & Gas Connections Hot Water Trunk Line Diameter

1-1/2"

Cold Water Trunk Line Diameter Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type Gas Trunk Line Diameter Gas Trunk Connection Type

1-1/2" Rigid Copper Rigid Copper 1-1/2" PIPE 1-1/4" 1-1/4” MNPT

Gas Trunk Line Material Gas Branch Line Material Electric Requirements Voltage Maximum Current (Amperes) Number of Tankless Water Heaters

Sch 40 Steel PVC Over CSST AC 120 Volts—60 Hz 8 BTU and Flow Rates for CU199i, (NG/LP) 2

Flow rate @ 70°F rise (gpm)

10.8

Flow rate @ 100°F rise (gpm)

7.6

Minimum input rate (Btuh) Maximum input rate (Btuh)

24

15,200 398,000

Rinnai Tankless Rack System Specification Sheet


FREE-STANDING RACKS Available Configurations • 2-Units, 3-Units, 4-Units, 5-Units, 6-Units

4-Unit Free-Standing Frame FRONT

LEFT

20.50

18.81

5.92 TYP

56.82

4.50 GAS (1-1/4”NPT) 9.38 COLD (2”COPPER)

34.53

14.38 HOT (2”COPPER)

26.29 28.59 BOTTOM

Model

Configuration

Illustration

Model

Configuration

Illustration

Inline

TRS02ILCU (facing same

TRS04CU

direction)

TRS02CU

TRS03CU

Back to Back

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

25


4-Unit Free-Standing Frame (Continued)

Model

TRS04CU

TRS03CU

Water Heater Model

TRS02CU

TRS02ILCU

CU199i, CU199e (NG/LP)

Crate Dimensions (HxLxD) - in

66 x 70 x 35

Weight - Fully Assembled - lbs

365

290

214

214

Weight - Shipping (total) - lbs

562

490

416

416

Rack Frame - Specifications Frame Rail Type

Sheet Metal

Frame Material

Aluminum (0.090 5052-H32)

Frame Finish

Powder Coat

Color

Gray

Water & Gas Connections Hot Water Trunk Line Diameter

2”

Cold Water Trunk Line Diameter

2”

Hot Water Trunk Line Material

Rigid Copper

Cold Water Trunk Line Material

Rigid Copper

Water Trunk Connection Type

2” PIPE

Gas Trunk Line Diameter

1-1/4”

Gas Trunk Connection Type

1-1/4” MNPT

Gas Trunk Line Material

Sch 40 Steel

Gas Trunk Branch Line Material

PVC Over CSST

Condensate Trunk Line Diameter

3/4”

N/A

Sch-40 PVC

N/A

3/4” Pipe

N/A

Yes (Indoor Models Only)

N/A

Condensate Trunk Material Condensate Trunk Connection Type Electric Requirements

Prewired Electrical Assembly Voltage Maximum Current (Amperes)

AC 120 Volts—60 Hz 16

12

8

BTU and Flow Rates for CU199i, CU199e (NG/LP) Number of Tankless Water Heaters

4

3

2

Flow rate @ 70°F rise (gpm)

21.6

16.2

10.8

Flow rate @ 100°F rise (gpm)

15.2

11.4

7.6

796,000

597,000

Minimum input rate (Btuh) Maximum input rate (Btuh)

TRS04CU

26

15,200

TRS03CU

398,000

TRS02CU

TRS02ILCU

Rinnai Tankless Rack System Specification Sheet


6-Unit Free-Standing Frame LEFT

FRONT

BOTTOM

Model

Configuration

Illustration

Model

TRS06CU

TRS36CU

TRS05CU

TRS46CU

TRS03ILCU

TRS23ILCU

Configuration

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

Illustration

27


6-Unit Free-Standing Frame (Continued)

Rack Frame - Specifications Frame Rail Type

Sheet Metal

Frame Material Frame Finish

Aluminum (0.090 5052-H32) Powder Coat

Color

Gray

Water & Gas Connections Hot Water Trunk Line Diameter

2-1/2"

2”

Cold Water Trunk Line Diameter

2-1/2"

2” Rigid Copper Rigid Copper

Hot Water Trunk Line Material Cold Water Trunk Line Material Water Trunk Connection Type

2-1/2” PIPE

2” PIPE

Gas Trunk Line Diameter Gas Trunk Connection Type

1-1/2" 1-1/2” MNPT

1-1/4” 1-1/4”MNPT

Gas Trunk Line Material Gas Branch Line Material

Sch 40 Steel PVC Over CSST

Condensate Trunk Line Diameter

3/4”

N/A

Condensate Trunk Line Material

Sch-40 PVC

N/A

3/4” Pipe

N/A

Condensate Trunk Connection Type Electric Requirements Prewired Electrical Assembly

Yes (Indoor Models Only)

Voltage

N/A

AC 120 Volts—60 Hz

Max Current (Amperes)

24

20

16

12

12

8

BTU and Flow Rates for CU199i, CU199e (NG/LP)

Number of Tankless Water Heaters

6

5

3

4

2

Flow rate @ 70°F rise (gpm)

32.4

27.0

16.2

21.6

10.8

Flow rate @ 100°F rise (gpm)

22.8

19.0

11.4

15.1

7.6

796,000

398,000

Minimum input rate (Btuh) Maximum input rate (Btuh)

TRS06CU

28

TRS05CU

15,200 1,194,000

TRS03ILCU

995,000

TRS36CU

597,000

TRS46CU

TRS23ILCU

Rinnai Tankless Rack System Specification Sheet


Venting Venting components are packaged separately from the pre-assembled rack for field assembly of the vent system by the contractor. The following vent options are available: • Direct Vent with Concentric Pipe IMPORTANT HE+ Series tankless water heaters must use concentric venting with a metal exhaust pipe. Refer to the Installation and Operation Manual supplied with the HE+ Tankless Water Heater for venting options. • •

Direct Vent with Twin Pipe Common Vent

Direct Vent (Concentric Pipe)

Direct Vent (Twin Pipe)

Combustion air and exhaust vent directly through a single concentric connection. Hot exhaust exits through the interior tube, while combustion air enters through the outer layer.

Combustion air and exhaust vent directly through separate penetrations. Exhaust Combustion air

Exhaust Combustion air

Combustion air

Common Vent

(Indoor Units Only. Direct Vent and Non-Direct/Room Air Vent)

Direct Vent

Non-Direct (Room Air) Vent

Multiple water heaters sharing a combustion air header and a separate exhaust header that vents directly through separate penetrations to the outside.

Multiple water heaters using room air for combustion while sharing an exhaust header that vents directly to the outside.

Exhaust

Exhaust

Combustion Air Room Air For Combustion

Rinnai Tankless Rack System Specification Sheet

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

29


Vent Options The following table lists the vent options for the CU Series, SE Series and SE+ Series tankless water heaters. HE+ Series tankless water heaters must use concentric venting with a metal exhaust pipe. Refer to the Installation and Operation Manual supplied with the HE+ Tankless Water Heater for venting options.

Vent Options for CU Series, SE Series, and SE+ Series Tankless Water Heaters Vent Options

Common Vent

Vent Material Exhaust

Polypropylene or Schedule 40 PVC/CPVC

Intake

Polypropylene or Schedule 40 PVC/CPVC

Diameter

Max. Units

Maximum Vent Length

3 in.

2

65 FT

4 in.

4

1-3 Units: 150 FT 4 Units: 65 FT

7

1-6 Units: 150 FT 7 Units: 70 FT

8

150 FT

Header Vent

4 in.

6 in.

6 in.

Concentric Pipe

Twin Pipe

Polypropylene

Polypropylene* or Schedule 40 PVC/CPVC

Schedule 40 PVC

Schedule 40 PVC/CPVC

5 in.

150 FT 1

4 in.

65 FT

3 in.

150 FT 1

2 in.

65 FT

* Twin Pipe Polypropylene venting is provided by Centrotherm through their own distribution network.

Multiple Water Heaters With use of cascade cable(s) up to 24 water heaters can be electronically connected. This connection will rotate water heater operation order to ensure equal usage among the entire system and enables all water heaters connected to modulate operation and function as one hot water source.

30

Rinnai Tankless Rack System Specification Sheet


COMMON VENT SYSTEM Features and Benefits The CVent Common Venting system provides longer vent lengths and fewer wall or roof penetrations than conventional single-unit venting. For the exhaust flue, CVent utilizes a CSA certified and tested venting (PPTL) and for Canada ULC-S636-certified and tested venting (PPS) material from Ubbink, the same supplier for Rinnai's innovative line of concentric venting. The various sections are self locking and sealing and can be pushed together without use of cement or glue. CVent is for use in U.S. and Canada only. PPTL components are certified for U.S. installations whereas PPS components are certified for Canadian installations.

Model Applicability The common vent system is CSA certified (ANSI Z21.10.3, Gas Water Heaters Standards) for use with the following Rinnai tankless condensing water heaters only: RU98i (REU-KB3237FFUD-US), RUC98i (REU-KBD3237FFUD-US), and C199i (REU-KBD3237FFUDC-US)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 1 SP-CV-4

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


COMMON VENT SYSTEM Maximum Equivalent Vent Length When determining equivalent exhaust and intake vent lengths add:

• •

6 feet for each 90° elbow

3 feet for each 45° elbow

Add any vent extension lengths which are added within the header due to increased spacing of the water heaters Header kits have already been counted and do not need to be added.

Tankless Rack System (TRS) Venting Configuration Summary (PPTL & PPS) TRS Configuration

Tankless Models

# of Tankless Units

Minimum Equivalent Vent Length (Ft)

Maximum Equivalent Vent Length (Ft)

Exhaust*

Exhaust*

Intake*

8

8 7 2 to 6

C199i (REU-KBD3237FFUDC-US); RUC98i (REU-KBD3237FFUD); RU98i (REU-KB3237FFUD-US)

8

One Elbow + Termination

2 to 6

Intake*

Vent Option

Appliance Adapter

Room Air Configuration

Exhaust Position

41 Appliance Adapter

7 C199i (REU-KBD3237FFUDC-US)

Approved C-Vent Configuration

80 100

9

41

41

80

80

100

100

41

41

15 2 to 7

100

100

Parallel Pipe Configuration (Different Pressure Zone) (Page 23) Parallel Pipe Configuration (Same Pressure Zone & Face the Same Direction) (Page 23)

Vertical Only

Vertical or Horizontal

*Approved exhaust and intake diameter is 8 inches.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 2 SP-CV-4


COMMON VENT SYSTEM When ordering the CVent exhaust components and the Tankless Rack System (TRS) together, please use the following table and part numbers.

Direct Vent 8" Common Venting Direct Vent Common Venting Description 8" back-to-back 3 unit header kit 8" back-to-back 4 unit header kit 8" back-to-back 5 unit header kit 8" back-to-back 6 unit header kit 8" back-to-back 7 unit header kit 8" back-to-back 8 unit header kit 8" in-line 3 unit header kit 8" in-line 4 unit header kit 8" in-line 5 unit header kit 8" in-line 6 unit header kit 8" in-line 7 unit header kit 8" in-line 8 unit header kit

Back-to-Back Configuration

U.S. (PPtl)

Canada (PPs)

Item Number

Item Number

CV8BB3USDV CV8BB4USDV CV8BB5USDV CV8BB6USDV CV8BB7USDV CV8BB8USDV CV8IL3USDV CV8IL4USDV CV8IL5USDV CV8IL6USDV CV8IL7USDV CV8IL8USDV

CV8BB3CADV CV8BB4CADV CV8BB5CADV CV8BB6CADV CV8BB7CADV CV8BB8CADV CV8IL3CADV CV8IL4CADV CV8IL5CADV CV8IL6CADV CV8IL7CADV CV8IL8CADV

In-line Configuration

Key: CV = common vent; 8 = 8 inch diameter; IL/BB= stand alone/back-to-back; US/CA = United States/Canada; DV/RA = direct vent/room air; 4/5/6/7/8 = no. of water heaters

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 3 SP-CV-4

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


COMMON VENT SYSTEM Room Air 8" Common Venting U.S. (PPtl)

Canada (PPs)

Item Number

Item Number

8" back-to-back 3 unit header kit 8" back-to-back 4 unit header kit

CV8BB3USRA CV8BB4USRA

CV8BB3CARA CV8BB4CARA

8" back-to-back 5 unit header kit

CV8BB5USRA

CV8BB5CARA

8" back-to-back 6 unit header kit

CV8BB6USRA

CV8BB6CARA

8" back-to-back 7 unit header kit

CV8BB7USRA

CV8BB7CARA

8" back-to-back 8 unit header kit

CV8BB8USRA

CV8BB8CARA

8" in-line 3 unit header kit

CV8IL3USRA

CV8IL3CARA

8" in-line 4 unit header kit

CV8IL4USRA

CV8IL4CARA

8" in-line 5 unit header kit

CV8IL5USRA

CV8IL5CARA

8" in-line 6 unit header kit

CV8IL6USRA

CV8IL6CARA

8" in-line 7 unit header kit

CV8IL7USRA

CV8IL7CARA

8" in-line 8 unit header kit

CV8IL8USRA

CV8IL8CARA

Room Air Common Venting Description

Back-to-Back Configuration

In-line Configuration

Key: CV = common vent; 8 = 8 inch diameter; IL/BB= stand alone/back-to-back; US/CA = United States/Canada; DV/RA = direct vent/room air; 4/5/6/7/8 = no. of water heaters

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 4 SP-CV-4


COMMON VENT SYSTEM CVent Starter Kit 790005 / 791008PPS* 8-Inch For Back-to-Back or In-line Combustion Air & Exhaust

1

2

3

4

7

NO

QTY

PPTL PART #’S

*PPS PART #’S

1

1

DESCRIPTION CVENT ENDPIECE (EXHAUST) W/ CLEANOUT & CONDENSATE DRAIN (32mm)

790042

NA

2

1

CVENT COMB AIR ENDPIECE D8

780046

NA

3

1

CVENT CONDENSATE TRAP (32mm Connection)

790048

NA

4

1

CVENT DRAIN HOSE AND CLAMPS

790049

NA

6

1

UBBINK INSTALLATION INSTRUCTION

NA

NA

7

1

CENTROCERIN LUBRICANT

NA

NA

CVent In-line Kit 790007 / 791009PPS* 8-Inch Header Kit For In-line Combustion Air & Exhaust

1

2

3

4

Ø4”

5

7

6 Ø3”

NO QTY DESCRIPTION

PPTL PART #’S

*PPS PART #’S

1

1

CVENT COLLECTOR, 1 CONNECTION, D8 X L20 X D4 (Exhaust)

790040

NA

2

1

CVENT ELBOW D4 X 87° WITH CLEANOUT

790039

NA

3

1

CVENT EXTENSION, D4 X L18

790035

NA

4

1

CVENT APPLIANCE ADAPTER WITH CHECK VALVE AND HOSE TRAP

790038

NA

5

1

CVENT COMB. AIR COLLECTOR, 1 CONNECTION, D8 X L20 X D3

780044

NA

6

1

CVENT COMB AIR FLEX FITTING, D3

780050

NA

7

1

CENTROCERIN LUBRICANT

NA

NA

*PPS kits and components are certified for use in Canada

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 5 SP-CV-4

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


COMMON VENT SYSTEM CVent Back-2-Back Kit 790008 / 791010PPS 8-Inch Header Kit For Back-to-Back Combustion Air & Exhaust 1

5

Ø4”

Ø3”

Ø3”

Ø4”

2

4

3

6

7

PPTL PART #’S

*PPS PART #’S

1

NO QTY DESCRIPTION 1

CVENT COLLECTOR, 2 CONNECTION, D8 X L20

790041

NA

2

2

CVENT ELBOW D4 X 87° WITH CLEANOUT

790039

NA

3

2

CVENT EXTENSION, D4 X L18

790035

NA

4

2

CVENT APPLIANCE ADAPTER WITH CHECK VALVE AND HOSE TRAP

790038

NA

5

1

CVENT COMB. AIR COLLECTOR, 2 CONNECTION, D8 X L20 X D3

780045

NA

6

2

CVENT COMB. AIR FLEX FITTING, D3

780050

NA

7

1

CENTROCERIN LUBRICANT

NA

NA

*PPS kits and components are certified for use in Canada

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 6 SP-CV-4


COMMON VENT SYSTEM CVent Starter Kit-Room Air 790058 / 791011PPS* 8-Inch For Back-to-Back or In-line Combustion Air & Exhaust (Room air is only for C199i in Commercial Common Vent Applications) 1

2

3

6

NO QTY DESCRIPTION

PPTL PART #’S

*PPS PART #’S

1

1

CVENT ENDPIECE (EXHAUST) W/ CLEANOUT & CONDENSATE DRAIN (32mm)

790042

NA

2

1

CVENT CONDENSATE TRAP (32mm Connection)

790048

NA

3

1

CVENT DRAIN HOSE AND CLAMPS

790049

NA

5

1

UBBINK INSTALLATION INSTRUCTION

NA

NA

6

1

CENTROCERIN LUBRICANT

NA

NA

CVent In-line Kit-Room Air 790059 / 791012PPS* 8-Inch Header Kit For In-line Combustion Air & Exhaust (Room air is only for C199i in Commercial Common Vent Applications) 1

1

Ø4”

2

3

2 Ø4”

3 4

NO QTY DESCRIPTION

4

5

PPTL PART #’S

*PPS PART #’S

1

1

CVENT COLLECTOR, 1 CONNECTION, D8 X L20 X D4 (Exhaust)

790040

NA

2

1

CVENT ELBOW D4 X 87° WITH CLEANOUT

790039

NA

3

1

CVENT EXTENSION, D4 X L18

790035

NA

4 5

1 1

CVENT APPLIANCE ADAPTER (ROOM AIR), CHECK VALVE, HOSE TRAP CENTROCERIN LUBRICANT

NA NA

NA NA

*PPS kits and components are certified for use in Canada

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 7 SP-CV-4


COMMON VENT SYSTEM CVent Back-to-Back Kit-Room Air 790060 / 791013PPS* 8-Inch Header Kit For Back-2-Back Combustion Air & Exhaust (Room air is only for C199i in Commercial Common Vent Applications)

2 1

1

2

Ø4”

3 Ø4”

4

3

4

5

PPTL PART #’S

*PPS PART #’S

1

1

CVENT COLLECTOR, 2 CONNECTION, D8 X L20

790041

NA

2

2

CVENT ELBOW D4 X 87° WITH CLEANOUT

790039

NA

3

2

CVENT EXTENSION, D4 X L18

790035

NA

4

1

CVENT APPLIANCE ADAPTER (ROOM AIR), CHECK VALVE, HOSE TRAP

NA

NA

5

1

CENTROCERIN LUBRICANT

NA

NA

NO QTY

DESCRIPTION

*PPS kits and components are certified for use in Canada

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 8 SP-CV-4

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


COMMON VENT SYSTEM

Termination Kits Cvent 8-in Roof Termination Kit 790057 / 791007PPS (can be used as Intake or Exhaust)

If roof termination is being used as intake the assembly must include the intake rain cap Centrocerin Lubricant

CVent 8-in Roof Termination (Outer shell: available in PPtl or PPS)

Cvent 8-in Wall Termination Kit (Combustion Air & Exhaust) 790004 (for use with PPtl and PPS material) Ø0.24” (Qty. 4) 31”

Ø7.89”

Ø12.2”

Centrocerin lubricant

Interior Slip Fit Wall Plate

(Material: Stainless Steel)

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 9 SP-CV-4

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


COMMON VENT SYSTEM

COMMON VENT COMPONENTS

CVent Elbow D8x90 degree #790023 / 791003PPS

CVent Elbow D8x45 degree

Inverter Coupling Kit With Condensate Trap #790032

CVent 8in Vent Rain Cap (Intake) #780053

CVent Elbow D8x90 degree Vertical Support #790029

CVent Extension D8xL18” #790020, D8xL39” #790021 / 791001PPS D8xL78” #790052 / 791006PPS

CVent 8in Vent Rain Cap (Exhaust) #790034

CVent Flat Roof Flashing #790002

Combustion Air PVC Adapter Kit #780037

CVent 8-in Bracket #790024

CVent 8-in Chase Cover #790030

CVent 8in Vent Distancer #790031

CVent Extension D4xL18” #790035 / 791004PPS D8xL39” #790028

CVent Pitched Roof Flashing (Including Storm Collar) #790003

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 10 SP-CV-4


COMMON VENT SYSTEM Intake Material Options for Combustion Air Vent:

•For extended Intake pipe runs, PVC can be used between the Intake Header and Termination. •Use the PVC adapter (described below) when transitioning from the PPTL/PPS intake header to the stainless steel Combustion Air Termination.

WARNING

The materials described below can only be used on the combustion air vent. The Ubbink Polypropylene CVent can be used on both the combustion air and exhaust. Field supplied PVC material can only be used on the combustion air side and MUST NOT be used for the exhaust.

Item Description

Approval Codes for Installation

Flue Material

United States Plastic Vent and/or combustion air components

PVC Schedule 40

ANSI/ASTM D1785

PVC - DWV

ANSI/ASTM D2665

CPVC Schedule 40

ANSI/ASTM F441

PVC

ANSI/ASTM D2564

CPVC

ANSI/ASTM F493

Plastic pipe cement and primer

Combustion Air PVC Adapter Kit (Part #: 790037) includes both a transition from the 8” (200mm) PP header to 8” PVC and an 8”PVC to 8” (200mm) termination PP to PVC ADAPTER: 8” (200mm) PP header to 8” PVC

PVC to TERMINATION ADAPTER: 8”PVC to 8” (200mm) termination

FIELD SUPPLIED PVC PIPE

Plastic pipe cement and primer

Fasten, secure, and support all vent materials using manufacturer and industry standards to avoid potential intake air leaks or blockage. Support horizontal vent runs a minimum of every 4 feet and all vertical vent runs a minimum of every 6 feet.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 11 SP-CV-4

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


COMMON VENT SYSTEM Terminations This appliance is only certified to use Rinnai terminations and mounted in the orientation shown below. Horizontal Termination Combustion Air Vent

Min 36”

Exhaust Vent

Min 36”

Combustion Air Vent

The exhaust and intake terminations must follow these clearances: [1] 12 inch minimum vertically from bottom of combustion air termination to ground or anticipated snow line.

INTAKE IS NOT ALLOWED WITHIN THE SHADED AREA

Combustion Air Vent Combustion Air Vent

Min 12” above grade or anticipated snow level

[2] From edge of exhaust termination to edge of intake termination: Minimum of 36 inches Maximum of 20 feet

Min 36” Max 20’

Combustion Air Vent

[3] 36 inch minimum from multiple exhaust CVents There should be a minimum of 36 inches between exhaust terminations in multiple common vent installations. The vent (exhaust and combustion air) terminations to be as specified in table in “Maximum Equivalent Vent Length” Section (model specific).

NOTE: During colder weather when the exhaust temperature is much hotter than the outside air, the exhaust fumes condense producing water vapor. As a result a plume of water vapor may be seen leaving the exhaust.

EXHAUST - CVent

MAXIMUM 20’ MINIMUM 36”

INTAKE - PVC

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us 12 SP-CV-4


Installation Venting Components for Use with SE+, SE, HE+ (Condensing & Non-Condensing), Commercial Tankless Water Heaters & Boilers Product ID

Product Description

List Price (U.S.)

146141

Roof Flashing Assembly Flat

$40

169044

Pipe Clamp Universal Plastic

$7

189950

Shingle Roof Flashing, 1/12 to 6/12 pitch

$71

189951

Shingle Roof Flashing, 6/12 to12/12 pitch

$71

189952

Shingle Roof Flashing, 8/12 to16/12 pitch

$71

222053

Condensate Trap, Version II

$48

224042

Universal Bug Guard

$130

224045

3 in. / 5 in. Thimble (1 piece per box)

$58

224049

3 in. / 5 in. Vent Support Bracket

$43

242141

Flashing for Metal Roof

$136

710342

3 in. / 5 in. Rubber Wall Plate White

$7

710602

3 in. / 5 in. Rubber Wall Plate Black

$7

50171949

Tile/Shingle Roof Flashing, 1/12 to 6/12

$78

50171954

Tile/Shingle Flashing, 8/12 to 16/12

$78

50171961

Tile/Shingle Flashing, 6/12 to 12/12

$78

102000012

3 in. / 5 in. Horizontal Flashing Panel

$14

222716

2 in. Pipe Clamp Plastic (Qty 10) (SENSEI™ SE+ ONLY)

$28

224055

2 in. / 4 in. Thimble (SENSEI™ SE+ ONLY)

$52

710265

2 in. / 4 in. Rubber Wall Plate White (SENSEI™ SE+ ONLY)

$6

710192

2 in. / 4 in. Rubber Wall Plate Black (SENSEI™ SE+ ONLY)

$6

169013

2 in. / 4 in. Pipe Clamp Metal (SENSEI™ SE+ ONLY)

$6

224056

2 in. / 4 in. Vent Support Bracket (SENSEI™ SE+ ONLY)

$39

169043

3 in. / 5 in. Pipe Clamp Metal (SENSEI™ SE+ ONLY)

$7

2018 SUGGESTED LIST PRICE (USD) • Page 2 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


Installation Venting Components for Use with HE+ (Former Luxury) and HE (Former Value) Series Tankless Water Heaters (Non-Condensing) Concentric Venting Termination & Termination Kits for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) Product ID

Product Description

List Price (U.S.)

184127

Roof Discharge Termination 18 in. (above roof)

$125

224046

Raised Horizontal Termination Kit (“Snorkel”)

$545

223191

8.7 in. Universal Non-Condensing Horizontal Termination Kit

$91

223181

11.5 in. Universal Non-Condensing Horizontal Termination Kit

$114

223183

11.5 in. Universal Non-Condensing Horizontal Termination

$62

223182

21 in. Universal Non-Condensing Horizontal Termination Kit

$120

223184

21 in. Universal Non-Condensing Horizontal Termination

$69

223187

21 in. Non-Condensing Horizontal Termination Diverter Kit Termination for Minimal Clearance

$120

185342

Roof Termination Ext Kit

$70

224054

Telescoping Vent Length

$60

184118-S

Roof Discharge Termination 18 in. (above roof)

$104

184119

Roof Discharge Termination 38 in. (above roof); cold climate

$145

223188

12 in. Universal Termination Metal Kit

$136

Concentric Venting Elbow Components for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) 224063

90 Degree Elbow

$52

224050

45 Degree Elbow (Qty of 2)

$71

224255

90 Degree Elbow (Metal)

$60

224250

45° Elbow (Metal)

$85

Concentric Venting Vent Pipe Extensions for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) 224051

10 in. Vent Pipe Extension

$41

224052

19.5 in. Vent Pipe Extension

$58

224053

39 in. Vent Pipe Extension

$64

224260

10 in. Vent Pipe Extension (Metal)

$52

224265

19.5 in. Vent Pipe Extension (Metal)

$69

224270

39 in. Vent Pipe Extension (Metal)

$79

Installation Accessories for Use with HE+ and HE Series Tankless Water Heaters (Non-Condensing) 222053

Condensate Trap

$48

224245

Condensate Collector

$77

2018 SUGGESTED LIST PRICE (USD) • Page 3 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


3 in. / 5 in. Installation Venting Components for Use with SE+ and SE Tankless Water Heaters (Condensing) and M, E, Q Series Boilers Product ID

Product Description

List Price (U.S.)

184162PP

3 in. / 5 in. Condensing Roof Discharge Termination 20in Above Roof

$90

185344PP

3 in. / 5 in. Roof Termination Extension Kit

$70

185346PP

3 in. / 5 in. Condensing Termination Extension

$82

185347PP

Separation Kit

$28

187585PP

Twin Pipe Adapter for use w/ PVC/CPVC (Special Order Only)

$60

223174PP

3 in. / 5 in. Condensing Horizontal Term Kit 8.7 in.

$84

223176PP

3 in. / 5 in. Condensing Horizontal Term Kit 12 in.

$90

223177PP

3 in. / 5 in. Condensing Horizontal Term Kit 21 in.

$94

223186PP

3 in. / 5 in. Condensing Horizontal Term Diverter Kit 19 in.

$100

224047PP

3 in. / 5 in. Condensing Raised Horiz Term Kit Snorkel

$380

224077PP

3 in. / 5 in. Condensing 45 Degree Elbow (Qty 2)

$50

224078PP

3 in. / 5 in. Condensing 90 Degree Vent Pipe Elbow

$36

224079PP

3 in. / 5 in. Condensing Vent Pipe Extension 19.5 in.

$40

224080PP

3 in. / 5 in. Condensing Vent Pipe Extension 39 in.

$47

224087PP

3 in. / 5 in. Condensing Vent Pipe Extension 10 in.

$32

196116PVC

3 in. Concentric PVC

$87

196985PVC

3 in. Low Profile PVC

$27

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. • “PP” at the end of the part number signifies Polypropylene venting components for use with SE and SE+ Condensing Tankless Water Heaters and Condensing Gas Boilers (M, E, Q Series) Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 4 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com


2 in. / 4 in. Installation Venting Components for Use with SENSEI™ SE+ Tankless Water Heaters (Condensing) and M-Series Boilers SENSEI™ Tankless Models

M-Series Condensing Boilers

RU130

RU199

M060SN

M160SN

M120CN

RU160

RUR160

M090SN

M060CN

M160CN

RU180

RUR199

M120SN

M090CN

CU160

CU199

Product ID

Product Description

List Price (U.S.)

222710NPP

2 in. Condensing 45 Degree Elbow (20/Box)

$8

222711NPP

2 in. Condensing 90 Degree Elbow (20/Box)

$10

222712NPP

2 in. Condensing Vent Pipe Extension 39 in. (4/Box)

$70

222714NPP

2 in. Condensing Vent Pipe Extension 79 in. (4/Box)

$95

222715NPP

2 in. Condensing Fixing Clip Metal (Qty 10)

$30

184470NPP

2 in. Condensing Flex Termination Kit

$230

222720NPP

2 in. Flex Connector

$24

222721NPP

2 in. Flex Roll (41.5 ft.)

$300

223085NPP

2 in. Condensing Wall Terminal Twin Pipe

$80

187595NPP

2 in. x 2 in. / 4 in. Condensing Twin Pipe Adaptor

$75

710202NPP

2 in. / 4 in. Condensing 90 Degree Diverter Nose

$17

710215NPP

2 in. / 4 in. Condensing 45 Degree Diverter Nose

$12

229011NPP

2 in. / 4 in. Condensing Horizontal Termination Kit 8.7 in.

$75

229012NPP

2 in. / 4 in. Condensing Horizontal Termination Kit 12 in.

$80

229013NPP

2 in. / 4 in. Condensing Horizontal Termination Kit 21 in.

$84

229016NPP

2 in. / 4 in. Condensing 21 in. Wall Term (2 wall plates)

$55

224356NPP

2 in. / 4 in. Condensing Roof Discharge Term 20 in. Above Roof

$80

229205NPP

2 in. / 4 in. Condensing 45 Degree Elbow Qty 2

$45

229230NPP

2 in. / 4 in. (60/100) Condensing 90 Degree Elbow

$32

229253NPP

2 in. / 4 in. Condensing Horizontal Starter Adapter

$35

229308NPP

2 in. / 4 in. Condensing Vent Pipe Extension 10 in.

$29

229309NPP

2 in. / 4 in. Condensing Vent Pipe Extension 19.5 in.

$36

229310NPP

2 in. / 4 in. Condensing Vent Pipe Extension 39 in.

$42

227412NPP

2 in. / 4 in. Condensing Vertical Starter Adapter

$45

185348NPP

2 in. / 4 in. Condensing Roof Term Extension Kit

$63

196005PVC

IPEX 2 in. Concentric Termination 2 x 16

$79

196105PVC

IPEX 2 in. Concentric Termination 2 x 28

$87

196125PVC

IPEX 2 in. Concentric Termination 2 x 40

$96

196984PVC

IPEX PVC Low Profile Termination 2 in.

$27

NOTES: • Warranty may change depending on application and use. For complete warranty details, visit rinnai.us/warranty or call 1-800-621-9419. * “NPP” signifies Polypropylene venting components for use with the NEW Rinnai SENSEI™ Condensing Tankless Water Heaters and M-Series Condensing Gas Boilers. Rinnai is continually updating and improving products; therefore, specifications and pricing are subject to change without prior notice. Local, state, provincial and federal and national fuel gas codes must be adhered to prior to installation. FOB Rinnai Georgia, Nevada and Pennsylvania.

2018 SUGGESTED LIST PRICE (USD) • Page 5 © 2018 Rinnai America Corporation | Effective Date 05/01/2018 | Revision Date 10/15/2018


Ubbink Vent Components - Concentric Non-Condensing  For concentric venting, non-condensing models.  Current water heater models incorporate a condensate collector and do not require an “adapter” vent component. (For models manufactured prior to 2008 a separate condensate collector is available)  Plastic vent components consist of an outer plastic vent for the air intake (ø5”) and an inner metal vent for the exhaust gases (Ø3”). Metal vent components consist of metal inner and outer vents.  Plastic and metal vent components are completely interchangeable. Refer to the Rinnai installation manual and the Ubbink installation instructions for complete installation details and requirements. PLASTIC VENT COMPONENTS

(Plastic Outer Pipe, Metal Inner Pipe)

Universal Non-Condensing Termination Kit

Part No.: 185342

L”

8.7”

223191

11.5” 21”

Part No.: 184118-S

Termination Only Length “L”

Part Number

223181

11.5”

223183

223182

21”

223184

61.4”

8.8”

39”

Part Number

Part No.: 184119

Roof Discharge Termination 18”

Termination Kit (termination, elbow, rubber wall plates) Length “L”

Roof Discharge Termination 38” (Cold Climate)

Roof Termination Extension Kit

Part No.: 223187 L”

Telescoping Vent Length Part No.: 224054

21”

(21” Non-Condensing Horizontal Termination Diverter Kit)

Rubber Wall Plate

Part No.: 710342 (White) Part No.: 710602 (Black) 45 Degree Elbow Part No.: 224050

Vent Pipe Extension

39”

224053

22.3”

224052

7.4”

19.5”

Effective Length 2.2-12 Inches

4.9”

224051

7.8”

10”

Condensate Collector Part No.: 224069

7.2”

2.3”

Part Number

6.4”

Length “L”

90 Degree Elbow Part No.: 224063

Ø0.78”

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us

© 2017 Rinnai Corporation

Ubbink-VA-SP-19

JXT Company | 828-735-1978 or 828-538-4311 | sales@jxtcompany.com

1/2017


Ubbink Vent Components - Concentric Non-Condensing METAL VENT COMPONENTS

(Plastic Outer Pipe, Metal Inner Pipe)

Universal Termination Kit (Metal)

Roof Termination (Metal)

Part No.: 223188 12”

90 Degree Elbow (Metal)

Part No.: 224255

Rubber Wall Plate

Part No.: 710342 (White) Part No.: 710602 (Black) 21”

12” Universal Horizontal Termination (Metal)

39”

7.8”

8.8”

7.2”

6.4”

L”

Part No.: 224250 Vent Support Bracket Part No.: 224049

Thimble Part No.: 224045

10”

224260

19.5”

224265

39”

224270

Part No.: 224245

Ø0.78” Raised Horizontal Termination Kit “Snorkel”

Roof Flashing

Part No.: 224046

15.75”

*Fits 2x4 or 2x6 Wall Construction

Roof Pitch 8.6” Ø5.0”

Horizontal—Flashing Panel Part No.: 102000012

1/12 to 6/12 6/12 to 12/12 8/12 to 16/12

7.4”

45 Degree Elbow (Metal)

Part Number

4.9”

2.3”

Condensate Collector (Metal) Length “L”

Part No. for Part No. for Shingle Roofs Tile Roofs 189950 189951 189952

50171949 50171961 50171954

Condensate Trap Part No.: 222053

Roof Flashing—Flat Part No.: 146141

NSF Cover Part No.: 224040

Flashing for Metal Roof Part No.: 242141

12.25”

Universal Bug Guard Part No.: 224042

4.15”

Pipe Clamp Part No.: 169044

Kit Includes: 14.2” Vent Extenstion, Qty 3-90° Elbow, 19.5” Vent pipe extension, Special wall terminal, Cover.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us


(PPs) - Polypropylene Ø3/5 (80/125) Ubbink Vent Components • For use on Rinnai CONDENSING water heaters only.

• Material of Outer/Combustion Air - Plastic.

• Do not combine the vent components illustrated on this page with any other vent components.

• Vent components consist of an outer plastic vent for air intake Ø5 in. (80 mm) and an inner polypropylene vent for the exhaust gases Ø3 in. (125 mm).

• Material of Inner/Exhaust - Polypropylene, Flame Retardant (ULC S636 Gas Vent-BH Class IIC 110°C/230°F)

Refer to the Rinnai Water Heater Installation and Operation manual for complete installation details and requirements. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

(PPs) POLYPROPYLENE VENT COMPONENTS

8.7” (221 mm)

223174PP

12” (305 mm)

223176PP

21” (533 mm)

223177PP

3/5 (80/125) Condensing Horizontal Termination Diverter Kit 19” (483 mm) Part #: 223186PP

3/5 (80/125) Condensing Vent Pipe Extension

L” 3/5 (80/125) Rubber Wall Plate Part No.: 710342(White) Part No.: 710602 (Black)

8.8” (223.5 mm)

3/5 (80/125) Thimble Part #: 224045

*Fits 2x4 or 2x6 Wall Construction

Part Number

10” (254 mm)

224087PP

19.5” (241 mm)

224079PP

39” (991 mm)

224080PP

Kit Includes: • 14.2” (361mm) Vent Extension (Qty. 3) • 90° Elbow • 19.5” (495mm) Vent Pipe Extension • Special wall terminal • Cover

3/5 (80/125) Condensing 45 Degree Elbow (Qty. 2) Part #: 224077PP

2” (53 mm)

3/5 (80/125) Vent Support Bracket Part #: 224049

Roof Flashing Assembly- Flat* Part #: 146141

Roof Flashing*

3/5 (80/125)Condensing 90 Degree Elbow Part #: 224078PP

5.5” (130 mm )

Universal Bug Guard* Part #: 224042

15.75” (400 mm)

8.6” 218 mm

3/5 (80/125) Pipe Clamp Metal Part #: 169043

Length “L”

25” (635 mm)

Part Number

4.7” (119 mm)

3/5 (80/125) Condensing Termination Extension Part #: 185346PP

Maximum Wall thickness “L”

3/5 (80/125) Condensing Roof Discharge Termination 25” (635 mm) above Roof Part #: 184228PP (for 6” B-Vent Flashing)

38” (203.2 mm)

L”

3/5 (80/125) Condensing Raised Horizontal Termination Kit “Snorkel” Part #: 224047PP

5.2” (32 mm)

3/5 (80/125) Condensing Horizontal Termination Kit (termination, elbow, rubber wall plates)

3/5 (80/125) Roof Termination Extension Kit Part #: 185344PP

20.3” (516mm)

38” (965mm)

3/5 (80/125) Condensing Roof Discharge Termination 20” above Roof Part #: 184162PP

Ø5.0” (127 mm)

Pipe Clamp Universal Plastic* Part #: 169044

3/5 (80/125) Horizontal— Flashing Panel Part #: 102000012

12.25” (311 mm)

4.15” (105 mm)

Roof Pitch

Part No. Shingle Roofs

Part No. Tile Roofs

1/12 to 6/12

189950

50171949

6/12 to 12/12

189951

50171961

8/12 to 16/12

189952

50171954

Flashing for Metal Roof* Part #: 242141 *Components are universal for use with 2/4(50/100) and 3/5 (80/125) components.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us © 2017 Rinnai Corporation

Ubbink-PP-SP-07

11/2017


(PPs) - Polypropylene Ø2” UBBINK COMPONENTS For use with the following models: RU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), CU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US). Refer to the Rinnai Water Heater Installation and Operation manual for complete installation details and requirements. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

(PPs) POLYPROPYLENE COMPONENTS 2 in. TWIN PIPE 2 in. (60) Condensing Wall Terminal Twin Pipe Part #: 223085NPP

2 in. TO CONCENTTRIC

2 in. FLEX

2 in. X 2/4 (60/100) Condensing Twin Pipe Adaptor Part #: 187595NPP

NOTE: FLEX VENTING MUST ONLY BE INSTALLED IN CONDENSING, VERTICAL, ROOM AIR APPLICATIONS. 2 in. (60) Condensing Flex Termination Kit Part #: 184470NPP

2/4 (60/100) Condensing Horizontal Termination Kit 21” (533 mm) (termination, rubber wall plates)

2 in. (60) Condensing Vent Pipe Extension

222712NPP

79” (2 m)

222714NPP

21” (533 mm)

2/4 (60/100) Rubber Wall Plate Part #: 710265 (White) Part #: 710192 (Black) 2 in. (60) Flex Roll X 41.5 Ft (12.5 m) Part #: 222721NPP

2 in. (60) Condensing 45 Degree Elbow Part #: 222710NPP

Roof Flashing*

2/4 (60/100) Vent Support Bracket Part #: 224056 15.75” (400 mm)

Ø4.0”(102 mm)

2/4 (60/100) Horizontal— Flashing Panel Part #: 102000022

12.25” (311 mm)

Fixing Clip Metal (Qty. 10) Part #: 222715NPP

38” (965 mm)

Includes: • 4 Vent Pipe Extensions • 4 Fixing Clips

(1) Clip required per vent connection

Pipe Clamp Universal Plastic* Part #: 169044

8.6” (218 mm)

39” (1 m)

Part #: 229016NPP

20.3” (516 mm)

Part Number

6.6” (168 mm)

L”

Length “L”

2/4 (60/100) Condensing Roof Discharge Termination 20” above Roof Part #: 224356NPP

Roof Flashing Assembly- Flat* Part #: 146141

2/4 (60/100) Thimble Part #: 224055

2 in. (60) Condensing 90 Degree Elbow Part #: 222711NPP 2 in. (60) Flex Connector Part #: 222720NPP

2 in. (60) Pipe Clamp Plastic (Qty. 10) Part #: 222716

Roof Pitch

Part No. Shingle Roofs

Part No. Tile Roofs

1/12 to 6/12

189950

50171949

6/12 to 12/12

189951

50171961

8/12 to 16/12

189952

50171954

Flashing for Metal Roof* Part #: 242141

Universal Bug Guard* Part #: 224042

* Components are universal for use with 2/4 (50/100) and 3/5 (80/125) components.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us © 2017 Rinnai Corporation

Ubbink-PP2-SP-00

11/2017


(PPs) - Polypropylene Ø2/4” (60/100) Ubbink Vent Components • For use with the following models: RU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), CU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US). • Do not combine the vent components illustrated on this page with any other vent components.

• Material of Inner/Exhaust - Polypropylene. • Material of Outer/Combustion Air - Plastic. • Vent components consist of an outer plastic vent for air intake Ø4 in. (100 mm) and an inner polypropylene vent for the exhaust gases Ø2 in. (60 mm).

Refer to the Rinnai Water Heater Installation and Operation manual for complete installation details and requirements. Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

(PPs) POLYPROPYLENE VENT COMPONENTS 2/4 (60/100) Condensing Horizontal Termination Kit (termination, elbow, rubber wall plates)

2/4 (60/100) Condensing 45 Degree Diverter Nose Part #: 710215NPP

2/4 (60/100) Condensing 90 Degree Diverter Nose Part #: 710202NPP

L”

Part Number

8.7” (221 mm)

229011NPP

12” (305 mm)

229012NPP

21” (533 mm)

229013NPP

2/4 (60/100) Condensing 21 in. Wall Termination (includes 2 wall plates) Part #: 229016NPP

2/4 (60/100) Condensing Horizontal Starter Adapter Part #: 229253NPP

2/4 (60/100) Condensing Vertical Starter Adapter Part #: 227412NPP Ø2/4” (60/100) connection

Ø2/4” (60/100) connection

7.9” (200mm)

19.5” (495mm)

Maximum wall thickness “L”

4.6” (117mm) Ø3/5” (80/125) connection

Fits 2x4 or 2x6 Wall Construction

Length “L”

Part Number

10” (254 mm)

229308NPP

19.5” (240 mm)

229309NPP

39” (991 mm)

229310NPP

2/4 (60/100) Vent Support Bracket Part #: 224056

4.0” (107mm)

Roof Flashing Assembly- Flat* Part #: 146141

Roof Flashing*

2/4 (60/100) Condensing 45 Degree Elbow (Qty. 2) Part #: 229205NPP

2/4 (60/100) Condensing 90 Degree Elbow Part #: 229230NPP

4.9” (124mm)

L”

Ø3/5” (80/125) connection

2.0” (51mm) Universal Bug Guard* Part #: 224042

8.6” (218mm)

2/4 (60/100) Pipe Clamp Metal Part #: 169013

2/4 (60/100) Condensing Vent Pipe Extension

3.35” (85mm)

2/4 (60/100) Rubber Wall Plate Part #: 710265 (White) Part #: 710192 (Black)

6.6” (168mm)

2/4 (60/100) Thimble Part #: 224055

3.3” (84mm)

2/4 (60/100) Condensing Roof Termination Extension Kit Part #: 185348NPP

20.3” (516mm)

38” (965mm)

2/4 (60/100) Condensing Roof Discharge Termination 20” above Roof Part #: 224356NPP

Ø4.0”(102mm) 2/4 (60/100) Horizontal— Flashing Panel Part #: 102000022

12.25” (311mm)

4.15” (105mm)

Pipe Clamp Universal Plastic* Part #: 169044

Roof Pitch

Part No. Shingle Roofs

Part No. Tile Roofs

1/12 to 6/12

189950

50171949

6/12 to 12/12

189951

50171961

8/12 to 16/12

189952

50171954

Flashing for Metal Roof* Part #: 242141 *Components are universal for use with 2/4(60/100) and 3/5 (80-125) components.

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us © 2017 Rinnai Corporation

Ubbink-PP24-SP-00

11/2017


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.