2011 Gas Equipment Catalog

Page 1


73 Convenient Locations MAINE

MASSACHUSETTS

138 Leighton Road P.O. Box 5008 207.623.2521 800.322.4700 Fax: 207.622.2533

43 Sword Street Auburn Industrial Park 508.757.9322 800.872.0211 Fax: 508.757.8981

180 Olde Canal Drive 978.937.9322 800.642.9322 Fax: 978.937.5522

Bangor 04401

Bedford 01730

580.584 Broadway 781.322.7111 800.963.7111 Fax: 781.324.7773

Biddeford 04005

Bellingham 02019

Augusta 04330

67 Target Industrial Circle 207.947.6905 800.432.7371 ME only Fax: 207.947.8211 22 Landry Street 207.282.7558 800.443.0505 Fax: 207.282.0299 Caribou 04736

420 Main Street 207.498.2526 800.339.3029 Fax: 207.498.2137 Ellsworth 04605

9 Buttermilk Road 207.667.9322 888.882.9322 Fax: 207.664.0201 Lewiston 04240

9 Forrestall Street P.O. Box 2546 207.784.4575 800.252.2000 Fax: 207.784.4205 S. Portland 04106

150 Postal Service Way 207.772.8364 800.482.0791 ME only Fax: 207.773.4571 Rockland 04841

22 Merrill Drive 207.594.6200 800.287.0015 Fax: 207.594.9185 West Bath 04530

P.O. Box 612 Bull Rock Bridge Road 207.442.7990 800.427.7990 Fax: 207.442.8377 Winslow 04901 Mail to: P.O. Box

1569 Waterville, ME 04903 Ship to: 37 Heywood Rd. Winslow, ME 04901 800.533.1172 F. W. Webb

207.872.5522 800.640.9322 Fax: 207.872.8207 Kennebec Supply

207.873.2111 Fax: 207.873.0152 Kentrol / Sevco

207.873.7741 800.452.1928 Fax: 207.873.2945 Webb Pump

207.873.7741 800.452.1928 Fax: 207.873.2945

Auburn 01501

160 Middlesex Turnpike 781.273.9322 800.221.9322 Fax: 781.270.0208 37 South Maple Street 508.966.4999 Fax: 508.966.1999 Boston 02118

237 Albany Street 617.482.8387 Fax: 617.423.7858 Brockton 02301

60 Industrial Boulevard 508.580.8310 800.544.9322 Fax: 508.584.6418 Canton 02021

152 Will Drive 781.828.5559 Fax: 781.828.8060 Dedham 02026

45 Commerce Way 781.329.6200 866.684.9322 Fax: 781.329.3531 Fitchburg 01420

Lowell 01851

Malden 02148

Methuen 01844

98 Lindbergh Avenue 781.325.7041 866.548.9322 Fax: 781.325.7051 Utilities Supply Co. (USCO)

781.395.9023 800.343.7555 Fax: 781.395.2329

New Bedford 02745

915 Church Street 508.995.9533 888.354.0048 Fax: 508.985.0934

Northampton 01060

135 Industrial Drive 413.586.8100 800.282.7721 MA only Fax: 413.586.6280 Pittsfield 01201

35 Commercial Street 413.448.8205 800.578.9322 Fax: 413.442.2251

135 Falulah Street 978.345.4121 800.322.0899 Fax: 978.343.3749

Plymouth 02360

Gloucester 01930

Salem 01970

51 Great Republic Dr. Blackburn Industrial Pk 978.283.7800 Fax: 978.281.7016 Greenfield 01301

340 Chapman Street 413.773.3644 800.564.3644 Fax: 413.773.8205 Haverhill 01835

270 Neck Road Ward Hill Business Park West 978.374.8448 800.521.7499 Fax: 978.373.7723 Hingham 02043

45 Pond Park Road 781.749.9322 Fax: 781.740.4652 Hyannis 02601

108 Breeds Hill Road 508.775.3890 800.352.3159 MA only Fax: 508.778.0409

3 Collins Avenue 508.830.4666 Fax: 508.830.0481 295 Bridge Street 978.744.6550 800.345.5025 Fax: 978.744.1444 Springfield 01104

153 Plainfield Street 413.781.1700 800.660.3141 Fax: 413.781.1705 Sturbridge 01566 Pipe Depot

9 Picker Road 508.347.3342 Fax: 508.347.4967 Woburn 01801

50 Everberg Road 781.933.1804 800.253.7838 Fax: 781.933.3528 HVAC Controls

781.933.1804 800.341.0110 Fax: 781.933.3528

NEW HAMPSHIRE

CONNECTICUT

NEW YORK

46 Henniker Street 603.223.6580 888.508.0050 Fax: 603.223.6585

182 Route 32 860.642.9081 888.642.9086 Fax: 860.642.9082

17 Erie Boulevard 518.472.9322 800.432.9322 Fax: 518.472.9399

Concord 03301

Franklin 06254

Albany 12204

Dover 03820

Hartford 06114

Binghamton 13904

Exeter 03833

Hartford 06114 Victor

Cazenovia 13035 Kentrol/Sevco – Control Equipment Corp. (CEC) Mail to: PO Box 330 Ship to: One Carriage

10 Sumner Drive 603.749.3100 800.582.7196 Fax: 603.749.5572 18 Continental Drive 603.772.3441 888.993.9322 Fax: 603.772.1866 Gilford 03249

302 Hounsell Avenue 603.524.9322 800.345.1771 Fax: 603.527.1554 Keene 03431

420 Winchester Street 603.357.1877 800 235.1218 NH only Fax: 603.357.7276 Lebanon 03766

55 Etna Road 603.448.1980 800.322.8707 Fax: 603.448.6057 Madison 03849

1173 Conway Road 603.367.8852 800.852.9203 Fax: 603.367.4647 Manchester 03103

25 Union Street 603.668.6488 800.789.6488 Fax: 603.668.7277 Nashua 03062

7 Redmond Street 603.883.3355 800.462.1440 NH only Fax: 603.595.7733

150 Locust Street 860.522.9322 800.252.9322 Fax: 860.246.3718 200 Locust Street 860.722.2433 800.243.9360 Fax: 800.274.2004 New Haven 06519

650 Ella T. Grasso Blvd. 203.865.6124 866.416.9322 Fax: 203.624.5027 Waterbury 06708

737 Bank Street 203.574.5959 800.572.6479 Fax: 203.753.2245 VERMONT Barre 05641

10 Clark Road 802.479.3373 800.244.5044 VT only Fax: 802.479.2932 Bennington 05201

240 East Road 802.447.2312 800.821.9506 Fax: 802.447.1481

Brattleboro 05301

231 John Seitz Dr. Exit 1 Industrial Park 802.257.4316 800.821.9511 Fax: 802.257.7690 Rutland 05701

RHODE ISLAND

3091 Cold River Road 802.775.1922 800.622.4365 Fax: 802.773.7044

3 Slater Road

Springfield 05156

Cranston 02920

Pipe, Valves, Fittings

401.463.3741 800.795.6390 Fax: 401.463.4103

Webb Pump Webb Piping Products

401.463.4108 866.850.7867 Fax: 401.463.6056 Webb Bio–Pharm

401.463.4176 877.932.2246 Fax: 401.463.4160 Warwick 02888

101 Jefferson Blvd. 401.463.8339 888.225.6850 Fax: 401.463.8661

3 Charlestown Road 802.885.8127 800.872.5303 Fax: 802.885.2685 St. Albans 05478

5 Franklin Park West 802.527.0531 800.696.3763 Fax: 802.524.2093 St. Johnsbury 05819

2409 Portland Street 802.748.8101 800.872.8028 Fax: 802.748.3478 Williston 05495

80 Park Avenue 802.879.5155 800.696.0340 Fax: 802.879.4848

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

62 Griswold Street 607.724.3170 888.593.9322 Fax: 607.724.4369

Place Lane 315.655.9700 Fax: 315.655.9701

Canandaigua 14424

5297 Parkside Drive Suite 425 585.393.9322 800.828.8824 Fax: 585-393-6500

Newburgh 12550-6405

600 Corporate Blvd. 845.567.0242 877.494.9322 Fax: 845.567.6019 Plattsburgh 12901

7327 Rte 9 518.562.2575 800.622.9322 Fax: 518.562.0117

Queensbury 12804

3 Highland Avenue 518.792.1316 800.826.0326 Fax: 518.792.1335 Syracuse 13211

6792 Townline Road 315.476.9322 800.262.9222 Fax: 315.472.4139 Utica 13501

415 Broad Street 315.724.3191 Fax: 315.724.4067


To our Valued Customers, We are pleased to bring you our 2011 Heating products catalog. If you’ve used our catalogs in the past, you’ll notice that something has changed with this edition. We’ve bundled our traditional heating catalog and our Victor gas catalog providing you with an easy to use, single source for all your Oil, Natural and LP Gas product needs. Inside you’ll find hundreds of product pictures, descriptions, specifications, and Webb part numbers as well as a wealth of technical and cross reference info. The numbers, when used with our WebbConnect online ordering system, will give you inventory status, pricing and ordering capability, all with a click of the mouse. With over 70 locations throughout New England and New York, you are never far from the products in this catalog. And, of course, we offer free delivery if that best suits your needs. All of our locations are listed to the left for easy reference. Please don’t hesitate to call the location most convenient to you for help at any time. Need to speak to an LP Specialist at Victor? Simply call 800-243-9360. Sincerely,

Jeff Pope President F.W. Webb Company

Easy Ordering ORDER ONLINE at: victormfg.com Charge to your account, or we accept MasterCard, VISA and Business American Express. Victor is in no way responsible for errors, omissions or typos in the Heating Catalog. Furthermore, the pictures, ads and editorials contained in the Heating Catalog are copyrighted and cannot be used in full or any part without express permission of the publisher.


GAS EQUIPMENT Victor is the Northeast’s leading distributor of these premier gas equipment manufacturers.


GAS EQUIPMENT CATALOG Table of Contents Section 1 2

Page Regulators & Accessories

Regulators, Regulator Reliefs, Pigtails, POL Fittings

1

Valves & Accessories

30

3 Meters/Meter Accessories

86

4

90

Cylinder and Service Valves, Multivalve Assemblies, Pressure Relief Valves & Relief Valve Manifolds, Globe & Angle Valves, Ball Valves, Excess Flow Valves, Filler Valves, Vapor Equalizing Valves, Internal Valves & Accessories, Adapters, Connectors & Fittings, Miscellaneous Equipment, Diagrams, Repair Kits Meters, Meters Bars, Manifolds, Accessories

5 6 7

Cylinders, Tanks & Accessories

ASME & Dot Cylinders, Motor Fuel Cylinders, Cylinder Cabinets, Cylinder Inverters, Scales, OPD Tools, Hand Trucks, ASME Tanks, ASME Replacement Parts, CAD Welding & Galvanic Protection

Paint & Supplies

102

Gauges

107

Gas Pipe, Tubing & Fittings

118

Tank Paint & Supplies, Decals & Signs Cylinder Gauges, Tank Gauges, Pressure Gauges TracPipe, Counter Strike, Copper Tubing, Coated Copper Tubing, Underground PE Pipe, Bulk Hose, Sediment Traps, Lyco Fittings, Continental Fittings, Dormont Connectors, SAE Fittings, Barbed Hose Fittings, Black Iron Fittings, Forged Steel Fittings

continued 4


GAS EQUIPMENT CATALOG Table of Contents (continued) Section 8

Page Gas Heating

149

Pumps/Compressors

174

Miscellaneous Equipment

205

Tools & Chemicals

211

13

Appendices

213

Index

9

10 11

Ignition Modules, Ignitors, Water Heater Controls, Gas Valves, Retrofit Kits, Water Safety Valves, Thermocouple & Thermopiles, Gas Orifices, Aluminum Tubing, Pilots, Hot Surface Igniters, Gas Valves Pressure Regulators Positive Displacement Meters, Hose Reels, Flex Connectors, Strainers, Swivel Connectors, Compressor Kits, Pump Station Kits, Propane Pumps, Selection Tables, Bypass Valves, Motors, Repair Parts Gas Conversion Burners, Vaporizers, Gas Lights, Gas Outlet Boxes Electrical Meters & Testers, Thermometers, Leak Detectors, Pressure Detectors, Carbon Monoxide Detectors, Underground Pipe Locators, Vacuum Cleaners, Gloves, Hand Tools, Power Tools, Flashlights, Lubricants, Chemicals, Test Kits

i


SECTION

1

Regulators Compact High Pressure First Stage Regulator

Inlet connection

MFR# LV3403TR

LV3403TR

1/4” F. NPT

outlet orifice connection size 1/2” F. NPT

1/4”

factory delivery pressure

bonnet vent position

vapor capacity btu/hr. propane*

Webb#

10 PSIG

Over Outlet

1,500,000

162774

* Maximum flow based on 15 PSIG inlet pressure and 8 PSIG delivery.

High Pressure First Stage Regulators LV4403 Series

Provides accurate first stage regulation in two-stage bulk tank systems. These regulators handle vaporization of tanks up to 1200 gallons. Reduce tank pressure to an intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Also incorporated in multiple cylinder installations. LV4403TR9

Inlet connection

MFR# LV4403SR4

outlet connection

orifice size

5

1-5

10

5-10

187110

5

1-5

162780

10

5-10

5

1-5

187109

10

5-10

162782

1/2” F. NPT

LV4403SR9

1/4”

LV4403TR9

F. POL

LV4403SR96

3/4” F. NPT

LV4403TR96

vapor capacity btu/hr. propane**

Adjustment range* (psig)

1/2” F. NPT

LV4403TR4

inTEGRAL relief included

factory delivery pressure

Webb# 187108

Yes

2,500,000

162781

* When used for final stage pressure control, must either incorporate integral relief valve or separate relief valve should be specified in accordance with NFPA Pamphlet 58. ** Maximum flow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the setting.

Second Stage Regulator for 2 PSIG Systems LV4403Y & LV5503Y Series

Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG. Systems that utilize this regulator use smaller than normal piping inside of the building. A special final stage regulator, not the appliance regulator, is required to reduce this intermediate 2 PSIG pressure down to 11” w.c. LV4403Y4 MFR#

Inlet connection

outlet connection

orifice size

LV4403Y4

1/2” F. NPT

1/2” F. NPT

1/4”

LV4403Y46R*

1/2” F. NPT

3/4” F. NPT

1/4”

LV5503Y6

3/4” F. NPT

3/4” F. NPT

1/4”

LV5503Y8

3/4” F. NPT

1” F. NPT

9/32”

ADJUSTMENT RANGE 2 PSIG at 10 PSIG Inlet 2 PSIG at 10 PSIG Inlet 2 PSIG at 10 PSIG Inlet 2 PSIG at 10 PSIG Inlet

bonnet vent position

vapor capacity btu/hr. propane**

Webb#

Over Inlet

1,000,000

192612

Over Inlet

1,000,000

250285

Over Inlet

2,200,000

250286

Over Inlet

2,200,000

250287

* Backmount Design ** Maximum flow based on 10 psig inlet pressure and 2 psig delivery pressure.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

1

1 regulators & accessories

Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring no more than 1,500,000 BTU’s/hr. These regulators are factory set to reduce tank pressure to an intermediate pressure of approximately 10 PSIG.


SECTION

1

Regulators

Low Pressure Second Stage Regulators Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11” W.C. Ideal for medium commercial installation, multiple cylinder installations and normal domestic loads.

LV4403B66R

Inlet connection

MFR# LV4403B4

outlet connection

orifice size

factory delivery pressure

ADJUSTMENT RANGE

vent position

vapor capacity btu/hr. propane

1/2” F. NPT

LV4403B46

162775

1/2” F. NPT

162776

LV4403B46R* LV4403B66

#28 Drill

3/4” F. NPT

LV4403B66R*

1” W.C. at 10 PSIG Inlet

935,000 9” to 13” W.C.

Over Inlet

162777 162778 162779

3/4” F. NPT

LV4403B66RA**

Webb#

1,000,000

LV4403B66RAB***

262352 262353

*Backmount Design. **90º Body. ***90º Body with Brackett.

Large Low Pressure Second Stage Regulators Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure. Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic systems.

LV5503B4

MFR#

Inlet connection

LV5503B4

1/2” F. NPT

LV5503B6

3/4” F. NPT

LV5503B8

outlet connection

orifice size

3/4” F. NPT

1/4”

1” F. NPT

9/32”

LV6503B14

11/2” F. NPT

11/2” F. NPT

LV6503B16

2” F. NPT

2” F. NPT

factory delivery pressure

11” W.C. at 10 PSIG Inlet

5/8”

ADJUSTMENT RANGE

BONNET vent position

9” to 13” W.C.

Over Inlet

81/2” to 14” W.C.

vapor capacity btu/hr. propane 1,600,000

Webb# 162783 162784

2,300,000

187111

8,000,000

241847

9,750,000

243018

Low Pressure Second Stage Tobacco Barn Regulator Especially developed for drying barns in the tobacco industry. The LV5503G regulator will supply steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn. LV5503G4

MFR# LV5503G4

2

Inlet connection 1/2” F. NPT

outlet connection 3/4” F. NPT

Gas Equipment Catalog

orifice size 1/4”

factory delivery pressure 15” W.C. at 15 PSIG Inlet

ADJUSTMENT RANGE

BONNET vent position

vapor capacity btu/hr. propane

Webb#

8” to 18” W.C.

Above Inlet

1,750,000

193313

victormfg.com


SECTION

1

Regulators Compact Twin Stage Regulators

1

This compact two-stage regulator is designed to reduce container pressure down to 11” W.C. or 2 psi delivery pressure. It is ideal for “on-site” cylinder applications, mobile homes and average domestic service including small ASME and 100 to 420 pound DOT cylinders.

Inlet connection

MFR# LV404B4 LV404B4V9

1/4” F. NPT

LV404B46

outlet connection

orifice size

factory ADJUSTMENT RANGE delivery pressure 2nd stage

1/2” F. NPT 3/4” F. NPT

LV404B9

.219

1/2” F. NPT

LV404B9V9

F. POL

LV404B96

11” W.C. at 100 PSIG Inlet

9” to 13” W.C.

3/4” F. NPT 1/2” F. NPT

LV404Y9

2 PSI

1.8 to 2.5 PSI

accessories 1st stage vent pipe-away

BONNET vent position 1st stage

BONNET vent position 2nd stage

Down

Over Outlet

162787

9 o’clock

9 o’clock

162788

Down

Over Outlet

Down

Over Outlet

9 o’clock

9 o’clock

Down

Over Outlet

Down

Over Outlet

capacity btu/hr. propane**

Webb#

162789

525,000

404PE

187105 214088 187106

800,000

359411

regulators & accessories

LV404B4

Compact Twin Stage Regulators The compact twin-stage regulator is designed to reduce container pressure down to 11” w.c. delivery pressure. It is ideal for “on site” container applications such as homes, mobile homes and cottages for average domestic service; including small ASME tanks and 100-420 pound DOT cylinders. LV404B34

LV404B39 accessories

Inlet connection

MFR# LV404B34

1/4” F. NPT

LV404B39

F. POL

LV404B34V9

1/4” F. NPT

LV404B39V9

F. POL

outlet connection 1/2” F. NPT

orifice size .100

factory delivery pressure 11” W.C. at 100 PSIG Inlet

ADJUSTMENT RANGE 2nd stage

BONNET vent position 1st stage

BONNET vent position 2nd stage

Rear

Over Outlet

Left

9 o’clock

9” to 13” W.C.

capacity btu/hr. propane**

1st stage vent pipeaway

2nd stage vinyl cover

bracket

162785 450,000

404PE

2302-55

191088

2302-31

162786 202171

Twin Stage Automatic Changeover Regulators These combination automatic changeover, two stage regulators are especially suitable for homes, mobile homes, cottages, construction and other portable two cylinder installations. Empty containers may be replaced without interrupting customer’s gas service. 7525B

MFR# 7525B23 7525B4

Service & reserve indicator Integral

inlet connections 1/4” Inverted Flare

outlet connections 1/2” F. NPT

factory delivery pressure* 11” W.C.

adjustment range 9” to 13” W.C.

Webb#

bonnet vent position Over Outlet

bracket included

capacity btu/hr. propane**

2302-31

200,000

162790

2503-22A

450,000

162792

Webb#

* Set at 100 PSIG inlet pressure. ** Maximum flow based on 25 PSIG inlet pressure and 9” water column delivery pressure.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

3


SECTION

1

Regulators

Automatic Changeover Regulator Outfits These outfits contain the equipment required to provide automatic changeover regulation.

7523B4

automatic changeover regulator included

MFR# 5726B23

7525B23

5727B23

7525B23

5744B4

7526B4

5745B4

7525B4

inlet 1/4”

Inverted Flare

outlet 1/2” F. NPT

pigtails included-2

pigtail sizes

912FA20

11/8” POL

912FS20

7/8” POL

912FA20

11/8” POL

912FS20

7/8” POL

bracket included

capacity btu/hr. propane

2312-31

200,000

2503-22

450,000

webb# 162794 162795 186861 186862

7523B23

Compact Regulators These compact regulators are designed for smaller outdoor grills and fish cookers. It is intended for use on small portable appliances that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe systems per NFPA 58, 1995 edition.

302V

302

MFR#

TYPE

302 302V9LS 302VW

Single Stage

Soft POL Without Orifice Hard Nose

PIGMEGR-766

Vent Port POL Hand Wheel 90º With QCC 1

PIGMEFMCULH

1/4” With QCC 1

302VW

4

OUTLET CONNECTION

ORIFICE SIZE

ADJUSTMENT RANGE

BONNET VENT POSITION

VAPOR CAPACITY BTU/HR. PROPANE

Small Vent Above Inlet

1/4” F. NPT

302V9 302V9

INLET CONNECTION

FACTORY DELIVERY PRESSURE

86837 273820

Drip Lip at 9 o’clock 3/8” F. NPT

Gas Equipment Catalog

No. 50 Drill

11” W.C. at 100 PSIG Inlet

162715 125,000

9” to 13” W.C. 9 o’clock Vent

WEBB#

273820 275124 186839 362733

Straight

362734

victormfg.com


SECTION

1

Regulators High Pressure Pounds-to-Pounds Regulator

1

Industrial/Commercial 597FA-D

Adjustment Method

MFR#

597FA 597FB 597FC 597FD

Tee Handle

Inlet connection

outlet connection

1/4” F. NPT

Recommended delivery PRessure Range (PSIG)

capacity determine at Set pressure of psig

capacity btu/hr. propane

Webb#

1-15 10-30 20-45 40-100

10 20 30 60

1,750,000 3,000,000 3,500,000 4,500,000

162716 162717 162718 162719

1/4” F. NPT

High Pressure Pounds-to-Pounds Regulators Commercial/Industrial

Designed to reduce LP gas and anhydrous ammonia container pressures to between 3 and 125 PSIG. Precision-built with a multi-million BTU capacity, the 1580M Series is perfect for such big, tough jobs as crop dryers, asphalt batch mixing plants, road building “tar wagons”, heat treating and other large industrial and commercial loads. 1584MW

MFR#

AA1582MW AA1582ML AA1582MH

Service

Adjustment Method

NH3

Inlet & outlet connection 1/4” F. NPT

1584MN 1584ML

LP-Gas 1/2” F. NPT

1584MH AA1584MW AA1584ML AA1574MH

NH3

1586MN 1586ML

Tee Handle LP-Gas 3/4” F. NPT

1586MH AA1586MW AA1586ML AA1586MH

1588MH

LP-Gas

3-25 20-50 45-125

1” F. NPT

Width

23/16”

height (max.)

capacity determine at Set pressure of psig

4”

20 30 60

3-30

20

25-50

30

45-125

215/16”

47/8”

60

3-25 20-25 45-125

20 30 60

3-30

20

25-50

30

45-125

60

3-25 20-50 45-125

NH3

1588MN 1588ML

Recommended delivery PRessure Range (PSIG)

31/2”

7”

20 30 60

3-30

20

25-50

30

45-125

60

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

capacity

Webb#

2,100 CFH NH3 2,400 CFH NH3 2,600 CFH NH3 7,000,000 BTU/hr. LPG 7,500,000 BTU/hr. LPG 8,000,000 BTU/hr. LPG 4,500 CFH NH3 4,800 CFH NH3 5,100 CFH NH3 11,000,000 BTU/hr. LPG 12,000,000 BTU/hr. LPG 14,000,000 BTU/hr. LPG 7,000 CFH NH3 7,700 CFH NH3 8,900 CFH NH3 11,000,000 BTU/hr. LPG 12,000,000 BTU/hr. LPG 14,000,000 BTU/hr. LPG

187087 187086 187085 162800 162799 186810 187089 162412 189234 162802 162801 189126 162414 162413 189235 162804 250280 162803

5

regulators & accessories

Designed to reduce propane gas container pressure down to between 3 and 100 PSIG. Ideal for liquid or vapor service, they can be used in a variety of applications including salamander heaters, weed burning torches, fish cookers, tar pot heaters, and other industrial type services.


SECTION

1

Regulator Accessories High Pressure/High Temperature Pounds-to-Pounds Industrial/Commercial

Designed to reduce LP-Gas container pressures to between 3 and 50 PSIG. Ideal for crop drying, heat treating, asphalt batch mixing and other large industrial and commercial load application utilizing high temperature LP-Gas or high temperature atmosphere under conditions up to 300°F.

X1584MW

MFR#

X1584MN X1584ML X1586MN X1586ML

Services

Adjustment Method

Inlet & outlet connection

Recommended delivery pressure range (PSIG)

Capacity determined at set pressure of psig

capacity btu/hr. propane

Webb#

3-20 25-50 3-30 25-50

20 30 20 30

7,000,000 7,500,000 11,000,000 12,000,000

190688 190687 250279 250290

1/2” F. NPT

LP Gas

Tee Handle 3/4” F. NPT

High Pressure Pounds-to-Pounds Regulator Accessories Industrial/Commercial

Designed for use as a relief valve on first stage regulators that comply with NFPA 58 2.57.5 exception: “first stage regulators with a rated capacity of more that 500,000 BTU/hr. shall be permitted to have a seperate relief valve. 3139

MFR#

Set pressure

Regulator settings

3139-18 3139-26 3139-38

18 PSIG 26 PSIG 38-PSIG

10 PSIG 16 PSIG 20 PSIG

connection size 1/4” M. NPT

height 227/32”

width 11/16”

flow capacity at 120% of set pressure (SCFH PRopane)

Webb#

1357* 1725** 2304***

266443 266437 315791

* Flow recorded at 21.6 PSI inlet pressure for this valve. ** Flow recorded at 31.2 PSI inlet pressure for this valve. *** Flow recorded at 45.6 PSI inlet pressure for this valve.

Victor/F.w. Webb offers webbConnect! you can order, check current pricing and inventory 24/7!

6

Gas Equipment Catalog

victormfg.com


SECTION

1

Regulator Accessories Copper Pigtails

MFR#

Connections

Approx. Length

tube

7/8” hex short nipple

11/8” hex long nipple

Webb#

Alt Marshall PIG#

Webb# —

912PS12

12”

188575

912PS20

20”

162812

30”

PIG1664-30

186531

912PS36

36”

162813

912PS48

48”

162814

912FS12

12”

216766

PIG1665-12

186532

162806

275012

162807

PIG1665-48

186535

12”

162808

PIG1663-48

186530

20”

162809

36”

188577

PIG1669-48

186539

912PS30

912FS20 912FS30

M. POL X M. POL

1/4” Inverted Flare X M. POL

912FS36 — 912JS12 912JS20 912JS36 —

POL X 1/4” Inverted Flare 1/4”

M. NPT X M. POL

48”

1/4”

POL X 1/4”

48” 20”

162810

M. POL X M. POL

36”

275011

PIG1660-36

186525

162811

162805

912PA48 912FA20

7/8”

30” 36”

912PA20 912pa36

20”

48” 1/4” Inverted

Flare X M. POL

11/8”

20”

913PS05

5”

273819

913ps12

12”

202603

913ps20

20”

188582

30”

250283

pig1680-30

186544

250284

188581

— —

913ps30

M. POL X M. POL

913ps36

36”

913ps48

48”

913js05a

5”

186999

12”

250282

20”

pig1684-20

186547

20”

187000

pig1679HP-20

186549

913js12 — 913s20

90º Pre Bent POL X 1/2 MPT 1/4” M. NPT X M. POL

3/8”

7/8”

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

7

1 regulators & accessories

912JS20

Pigtails are available in a variety of connections, sizes and styles. Care should always be taken in selecting the proper pigtail for a particular application. Note: Engineered Controls International, Inc., recommends a new pigtail be installed with every new and replaced regulator.


SECTION

1

Regulator Accessories Patented Pigtail Products

Applicatoin: Pigtails are available in a variety of sizes and styles. Care should always be taken in selecting the proper pigtail for a particular application. Patented presto-tap pigtail part numbers 1/4” Tube connections M.POL x M.POL

1/4” Inverted Flare x M.POL 1/4” M. NPT x M.POL

Fugitive emission reduction Webb #

approx. length

7/8” hex short nipple

pigtail length

1/4” tube

3/8” tube

12”

PT912PS12

12”

80%

91%

244167

20”

PT912PS20

20”

82%

NA

433019

48”

PT912PS48

48”

88%

NA

433020

20”

PT912FS20

12”

PT912JS12

20”

PT912JS20

3/8” TUBE

approx. length

7/8” hex short nipple

M.POL x M.POL

12”

PT913PS12

1/4” M. NPT x M.POL

12”

PT913JS12

connections

Pigtails

Patented Tank Pressure Fittings Application: The patented Presto-Tap LDS2000RV is designed to obtain pressure readings and perform system leak testing using tank pressure without ever breaking the system. Meets NFPA 54 & 58 requirements regarding excess flow. Compatible with all Presto-Tap® gauge products when used at correct locations

Patented tank pressure fitting part # LDS2000RV

thread

core

body wrench flat

cap wrench flat hex

#54 orifice

application

1/8 NPT

Viton

7/16

9/16

Yes

Tank Pressure

Webb # 244172

Regulator & Appliance Fitting Application: The RVL low pressure fitting is designed to obtain pressure readings at first and second sage regulators. Compatible with all Presto-Tap® gauge products when used at correct locations.

regulator & appliance fitting part # RVL

8

thread

core

body wrench flat

cap wrench flat hex

#54 orifice

application

1/8 NPT

Viton

7/16

9/16

No

Low Pressure

Gas Equipment Catalog

Webb # 433023

victormfg.com


SECTION

1

Regulator Accessories Presto-Tap® High Pressure Gauge Products & Accessories

1

part numbers

gauge bleeder (244170)

6800-90

90° quick adapter (244173)

straight quick adapter (433013)

X

X

X

244174

X

433007

6800-B90

X

X

X

6800-BH90

X

X

X

6800D-90

glycerin filled gauge (433005)

dry gauge (433004)

belt loop holster (433012)

belt Loop Holster (379916)

X

webb #

433018

X

X

X

433010

X

433010

6800D-B90

X

X

X

6800D-BH90

X

X

X

regulators & accessories

Application: 300# Gauge is used to obtain pressure readings and perform leak tests at tank pressure locations prior to 1st stage regulators such as Presto-Tap® pigtails and RegO “Ready To Go Valves”.

X

433011

Presto-Tap® Low Pressure Gauge Products & Accessories Application: 30# Gauge is used to perform leak tests downstream of 1st stage regulators by connecting quick adapters to Presto-Tap® LDS2000RV installed in 1st & 2nd stage regulator taps accessing 1st stage pressure.

first stage regulator leak testing 0-30# gauge products

part numbers

gauge bleeder (244170)

90° quick adapter (244173)

straight quick adapter (433013)

glycerin filled gauge (433005)

dry gauge (433004)

belt loop holster (433012)

belt Loop Holster (379916)

webb #

first stage regulator leak testing 0-30# gauge products PT30-LP

X

X

X

X

433015

low pressure leak leak testing 0-35# WC gauge products PT-OZ

X

X

N/A

X

X

433016

Presto-Tap® Patented Tank Pressure Fitting Application: Low cost, permanently installed fitting between tank service valve and first stage regulator providing leak test capability without the use of tools. Eliminates the need to discard pigtail to access tank pressure.

tank pressure fitting part #

thread

core

body wrench flat

TPF

1/4” F. NPT

1/4” F. NPT

Up to 90%

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Webb # 260646

9


SECTION

1

Regulator Accessories POL Inlet Fittings

These inlet fittings are available for assembly into either first stage or single stage regulators. All except for 970JR (1/4” hose barb) are machined from brass.

970

970AX

970AW

970HT

970AXS

970S

MFR#

description

Webb#

970 970AX 970AXS 3199W 970AW 970HT 970S 970JR

Hard nose POL with wrench nut. Hard nose POL with wrench nut and excess flow. Soft nose POL with wrench nut and excess flow. Heavy duty hard nose POL with wrench nut and excess flow. Soft nose POL with handwheel. Soft nose POL with handwheel and 60 DMS orifice. Soft nose POL with wrench nut and 60 DMS orifice. Hard nose POL X 1/4” hose barb.

191818 187003 246565 186856 187002 243117 162771 190842

Brackets RegO® Brackets are especially designed for use in installing RegO® Regulators in applications requiring the use of a bracket. MFR#

2503-19

2503-22

2302-31

2302-31 2503-22 2503-19

material Cadium Plated Steel Aluminum

for use with regulator model

Webb#

2302 Series/404B23

162798 162797 162796

LV404 Series, 2503 Series, LV4403 Series

Tee Check Manifolds For use in systems that require uninterrupted gas service during cylinder exchange. Especially for summer cottages, mobile homes and single appliance loads.

1450R 1350R

MFR#

Inlet connections

outlet connection

1350R 1450R

F. POL 1/4” Inverted Flare

M. POL 1/4” M. NPT

Webb#

Marshall PIG#

Webb#

162820 162821

PIG1000A PIG1702A

186519 186552

Multiple Cylinder Manifolds Use with suitable pigtails to connect multiple cylinders together. Ideal for loads that require more than one cylinder to be in service at a time. 1450E 1350E

10

MFR# 1350E 1450E —

Inlet connections

outlet connection

F. POL M. POL 1/4” Inverted Flare 1/4” M. NPT 11/8” HEX L/Check

Gas Equipment Catalog

Webb# 162819 162822 —

Marshall PIG#

Webb#

PIG1701B PIG1702B

186551 186553

victormfg.com


SECTION

1

Regulators Model 046 First Stage Field Regulators description

EQU046-12 EQU06-16 EQU06-20

Body

Webb#

Str

181910 181929 181930

3/4”

High Pressure Regulator First stage with internal relief valve.

1

1” 11/4”

Yellow Spring (04600-021-00) Outlet Pressure 3-10 psi at 75 psi Inlet Pressure Natural Gas (Sp 0.6) Capacity (scfh) Orifice Outlet PRessure PSI 5 10

orifice size Body Size 3/4” 1” 11/4” 3/4” 1” 11/4”

1/8”

3/16”

1/4”

5/16”

3/8”

1/2”

1190 1190 1190 1190 1190 1190

2213 2213 2213 2213 2213 2213

2775 3975 3975 3638 3900 3900

3150 6150 6375 4258 5395 5395

3375 6375 8100 4453 5775 5940

4013 7123 7030 6435 5920 6660

1350 BTU Propane/air mix (Sp 1.20) Capacity (scfh) Orifice Outlet PRessure PSI 5 10

orifice size Body Size 3/4” 1” 11/4” 3/4” 1” 11/4”

1/8”

3/16”

1/4”

5/16”

3/8”

1/2”

845 845 845 845 845 845

1571 1571 1571 1571 1571 1571

1970 2822 2822 2583 2769 2769

2237 4367 4526 3023 3830 3830

2396 4526 5751 3162 4100 4217

2849 5057 4991 4569 4203 4720

propane (sp 1.53) Capacity (btu/hr)* Outlet PRessure PSI 5 10

Body Size 3/4” 1” 11/4” 3/4” 1” 11/4”

orifice size 1/8”

3/16”

1/4”

5/16”

3/8”

1/2”

1,866,000 1,866,000 1,866,000 1,866,000 1,866,000 1,866,000

3,468,272 3,468,272 3,468,272 3,468,272 3,468,272 3,468,272

4,349,024 6,229,952 6,229,952 5,702,496 6,113,016 6,113,016

4,938,680 9,641,000 9,991,808 6,675,304 8,456,712 8,456,712

5,289,488 9,991,808 12,696,264 6,978,840 9,051,344 9,310,096

6,289,664 11,163,656 11,019,352 10,086,352 9,280,240 10,439,648

* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

11

regulators & accessories

MFR#

Pipe Sizes


SECTION

1

Regulators Model 143-80 Second Stage Service Regulators

The 143-80 is designed and built for domestic gas service, as well as for commercial and industrial applications; burners, furnaces, ovens, heaters, gas engines, etc. it can also be used for air, LPG, nitrogen, dry CO2 and other gases. Simple, rugged construction means dependability. Yet, it provides precise pressure control over an amazing range of pressure and load conditions. It is simple to install and adjust. The union nut connection makes it easy to locate the regulator in the best installed position, and servicing is easy and convenient. MFR#

description

143-80-212 143-80-216

Regulator With Internal Relief Valve (IRV)

143-80-220 143-80-2HP

Special High Pressure Outlet Up To 6 psi

Spring Ranges

SIZE

Webb#

3/4” Body

181913

1” Body

181909

11/4” Body

188875

1” Body

247441

Maximum Inlet Pressures

Outlet Pressure ranges

spring color

spring part number

31/2” to 61/2” w.c.

Red

143-62-021-15

181952

5” to 81/2” w.c.

Blue

143-62-021-16

188872

Webb#

6” to 14” w.c.

Green

143-62-021-17

274440

12” w.c. to 1 psi

Orange

143-62-021-18

186673

1/2” psi to 2 psi

Black & White

143-92-021-22

188876

2 psi to 6 psi

Black*

139-16-021-01

* Good for use in 143 802HP Series only

orifice sizes

5/8”

1/2”

3/8”

5/16”

1/4”

3/16”

1/8”

Max Inlet Pressure

10 psi

20 psi

40 psi

40 psi

60 psi

125 psi

125 psi

Capacities for Other Gases For capacities (in SCFH) of other gases, multiply the capacity values by a correction factor from the table below: other gases

specific gravity

correction factor

Propane

1.53

0.63

Natural Gas Chart

143-80-2, and 143-80-2HP­—Capacity in SCFH Natural Gas (0.6 Specific Gravity, 14.65 psia, 60ºF) Pipe size

3/4” X 3/4”

Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125

orifice size 1/8”

250 310 370 530 860 1200 1500 1800

3/16”

420 560 700 830 1200 1570 1660 1710 1900

1/4”

530 600 700 840 950 1220 1330 1520

5/16”

3/8”

1/2”

5/8”

480 560 620 720 860 970 1240 1340

340 500 570 630 730 880 1000 1250 1450

450 510 580 650 770 900 1020 1270

510 530 600 670 790 900 1020

Pipe size

1” X 1”

Pipe size

11/4” X 11/4”

12

Gas Equipment Catalog

Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125 Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125

orifice size 1/8”

250 310 370 530 860 1200 1540 2100

3/16”

420 580 700 840 1230 1700 1900 2000 2100

1/4”

530 650 890 1140 1360 2000 2000 2000

5/16”

3/8”

1/2”

5/8”

480 700 870 1120 1340 1500 1600 1640

350 550 840 1000 1160 1270 1330 1480 1900

460 600 880 920 950 1140 1200 1400

520 650 780 810 970 1060 1180

orifice size 1/8”

250 310 370 630 860 1200 1550 2250

3/16”

420 580 700 840 1230 1800 2100 2200 2400

1/4”

530 650 890 1140 1360 1600 2200 2400

5/16”

3/8”

1/2”

5/8”

480 700 870 1180 1500 1700 1800 1900

350 550 840 1030 1350 1610 1710 1900 2000

460 680 1020 1200 1490 1580 1800 1900

520 760 1030 1050 1060 1060 1180

victormfg.com


SECTION

1

Regulators Model 143-80 Second Stage Service Regulators (continued)

1

143-80-2, and 143-80-2HP­—Capacity in 1000’s of BTU’s of Undiluted Propane (1.5 Specific Gravity, 14.65 psia, 60ºF)

Pipe size

3/4” X 3/4”

Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125

orifice size 1/8”

392 486 580 831 1348 1861 2351 2821

3/16”

658 878 1097 1301 1881 2461 2602 2680 2978

1/4”

831 940 1097 1317 1489 1912 2085 2383

5/16”

3/8”

1/2”

5/8”

752 878 972 1129 1348 1520 1944 2100

533 784 893 987 1144 1379 1567 1959 2273

705 799 909 1019 1207 1411 1599 1991

799 831 940 1050 1238 1411 1599

* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

Pipe size

1” X 1”

Pipe size

11/4” X 11/4”

Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125 Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125

orifice size 1/8”

392 486 580 831 1348 188 2414 3292

3/16”

658 909 1097 1317 1928 2665 2978 3135 3292

1/4”

831 1019 1395 1787 2132 3135 3135 3135

5/16”

3/8”

1/2”

5/8”

752 1097 1364 1756 2100 2351 2508 2571

549 862 1317 1567 1818 1991 2085 2320 2978

721 940 1379 1442 1489 1787 1881 2194

815 1019 1223 1270 1661 1850

orifice size 1/8”

392 486 580 987 1348 1881 2430 3527

3/16”

658 909 1097 1317 1928 2821 3292 3448 3762

1/4”

831 1019 1395 1787 2132 2508 3448 3762

5/16”

3/8”

1/2”

5/8”

752 1097 1364 1850 2351 2665 2821 2978

549 862 1317 1614 2116 2524 2680 2978 3135

721 1066 1599 1881 2335 2477 2821 2978

815 1191 1614 1646 1661 1661 1850

Victor/F.w. Webb has over 125 outside sales people available to help you. If you need technical expertise, we’ve got it!

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

13

regulators & accessories

Propane Gas Chart*


SECTION

1

Regulators Model 243 Second Stage Service Regulators

These large capacity service regulators are designed and built for commercial, industrial and gas distribution work. They are right at home in such places as factories and foundries, district regulator stations, commercial laundries and laundromats, motels-hotels and apartments, bakeries, restaurants, schools, churches and hospitals. The versatile 243 is used for all kinds of gas fueled equipment. . .boilers, burners, furnaces, ovens, heaters, kilns, engines, air conditioners, etc. Remarkable field versatility results from the union connection between the fully interchangeable bodies and diaphragm-case assemblies. They are easy to install, adjust, inspect and service in all kinds of piping arrangements. While used primarily for natural gas services, Model 243 regulators perform equally well on LPG vapor, air, dry CO2, nitrogen and other inert gas applications. Basic Models MFR#

description

243-12-224 243-12-232

SIZES

12” Diaphram with Internal Relief

243-8-220

181915 181916

11/4” Body

181917

243-8-232 243-8HP-2

Webb#

2” Body -20ºF to 150ºF

11/2” Body

8” Diaphram with Internal Relief

243-8-224

Temperature limit

11/2” Body

Special High Pressure Regulator

181918

2” Body

259165

2” Body

247442

Outlet Pressure Ranges and Springs Spring color

Outlet pressure range 243-12

243-8

spring part#

webb#

Red-Black

31/2” to 61/2” w.c.

143-82-021-00

181954

Blue-Black

5” to 81/2” w.c.

143-82-021-01

Green-Black

6” to 14” w.c.

143-82-021-02

Red

31/2” to 61/2” w.c.

143-16-21-03

188870

Blue

5” to 81/2” w.c.

143-16-021-04

Green

6” to 14” w.c.

12” to 28” w.c.

143-16-021-05

254467

Orange-Black

10” to 18” w.c.

143-16-021-11

Orange

12” to 28” w.c.

1 to 2 psi

143-16-021-06

181953

Black

1 to 2 psi

2 to 41/2 psi*

143-16-021-07

181934

Cadium

11/2 to 3 psi

3 to 61/2” psi*

143-16-021-08

188871

Cadium

143-16-021-08

White

6 to 10 psi*

Clamping Plate

143-16-021-13

143161020100

308181

* Good for use in 243 8HP Series only

Capacities for Other Gases For capacities ( in SCFH) of other gases, multiply the capacity values by a correction factor from the table below: other gases

specific gravity

correction factor

Propane

1.53

0.63

14

Maximum Inlet Pressure, psig orifice size and Angle Regulator Model And Size 11/4”, 243-12 11/2”, 243-12 2”, 243-12 11/4”, 243-8 11/2”, 243-8 2”, 243-8 11/4”, 243-8HP 11/2”, 243-8HP 2”, 243-8HP

Gas Equipment Catalog

11/4”

11/4”*

1”

1”*

3/4”

3/4”

1/2”

3/8”

1/4”

.207”

30

10

30

10

30

10

10

10

10

10

15 15 15 — — — — — —

25 25 25 — — — — — —

25 25 25 — 25 25 — 25 25

40 40 40 — — — — — —

— — 40 — — 40 — — —

60 60 60 40 40 40 40 40 40

100 100 100 80 80 80 80 80 80

125 125 125 100 100 100 100 100 100

125 125 125 125 125 125 125 125 125

— — — 125 125 — — — —

victormfg.com


SECTION

1

Regulators 243 Variations

1

Internal Relief Valves

Model 243 Capacity Tables Natural Gas Chart

11/2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size 11/2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05

orifice size and valve angle

Inlet pressure (psi)

11/4”

1”

3/4”

1/2”

3/8”

1/4”

30

30

10

10

10

10

1 2 5 10 15 25 40 60 80 100 125

2700 4000 6000 8800 10000

2300 3500 5600 8200 9800 11500

1900 2700 4500 6500 7700 9700 11500 12500

1100 1900 3500 5500 6800 8100 9700 11500 12000 12500

750 1200 2100 2900 3800 5100 7100 9300 10500 11000 11000

400 600 1000 1400 1750 2400 3200 4400 5600 7000 8000

pipe size 11/2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06

Inlet pressure (psi)

11/4”

1”

3/4”

1/2”

3/8”

30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

6500 8000 9000 12000

5000 7500 8500 11500 13500

4000 6000 8000 10000 11500 13000 15000

2000 4000 5500 7000 9500 11000 13500 15000 16000

1300 2200 3000 4000 5500 7400 10000 13000 14000 14000

500 1000 1400 1800 2400 3300 4500 6000 7000 8500

1/4”

Propane Gas Chart

11/2” Model 243-12-2 Capacity Table in 1000’s of BTU’s or Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle pipe size 11/2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05

orifice size and valve angle

Inlet pressure (psi)

11/4” 30

30

10

10

10

10

1 2 5 10 15 25 40 60 80 100 125

4232 6270 9405 13793 15674

3605 5486 8778 12853 15361 18026

2978 4232 7053 10188 12069 15204 18026 19593

1724 2978 5486 8621 10659 12696 15204 18026 18809 19593

1176 1881 3292 4546 5956 7994 11129 14577 16458 17242 17242

627 940 1567 2194 2743 3762 5016 6897 8778 10972 12540

1”

3/4”

1/2”

3/8”

1/4”

pipe size 11/2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06

Inlet pressure (psi)

11/4” 30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

10188.4 12539.5 14107 18809.3

7837.2 11755.8 13323.2 18025.6 21160.4

6269.76 9404.64 12539.5 15674.4 18025.6 20376.7 23511.6

3134.88 6269.76 8620.92 10972.1 14890.7 17241.8 21160.4 23511.6 25079

2037.67 3448.37 4702.32 6269.76 8620.92 11599.1 15674.4 20376.7 21944.2 21944.2

783.72 1567.44 2194.42 2821.39 3761.86 5172.55 7053.48 9404.64 10972.1 13323.2

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

1”

3/4”

1/2”

3/8”

1/4”

15

regulators & accessories

The 243 is available with an internal relief valve (IRV). It’s a built-in safety device for providing a limited level of over-pressure protection. Like any relief valve, an IRV must be carefully sized. Internal relief valves are not available in the high pressure Model 243-8HP.


SECTION

1

Regulators Model 243 Capacity Tables

(continued)

Natural Gas Chart

11/2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size 11/2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07

orifice size and valve angle

Inlet pressure (psi)

11/4”

1”

3/4”

1/2”

3/8”

1/4”

30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

2800 5500 8000 10000

2450 5100 7500 9100 11000

1500 3700 5700 7100 9300 11000 12500

1200 2400 4000 5300 7300 9300 11000 12500 13000

850 1600 2700 3700 5100 7100 9300 10500 11000 11000

500 950 1400 1750 2400 3200 4600 5600 7000 8000

pipe size 11/2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08

Inlet pressure (psi)

11/4”

1”

3/4”

1/2”

3/8”

30

30

10

10

10

10

5 10 15 25 40 60 80 100 125

6000 10000 13000

5300 9300 12000 14500

4100 7100 8800 11000 13500 15000

2700 4700 6200 8600 11000 13500 15000 16000

1700 2900 3800 5200 7100 10000 12000 12000 12000

900 1400 1700 2400 3200 4600 5600 7000 8000

1/4”

Propane Gas Chart

11/2” Model 243-12-2 Capacity Table in 1000’s of BTU’s or Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle pipe size 11/2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07

orifice size and valve angle

Inlet pressure (psi)

11/4” 30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

4389 8621 12540 15674

3840 7994 11756 14264 17242

2351 5800 8934 11129 14577 17242 19593

1881 3762 6270 8307 11442 14577 17242 19593 20377

1332 2508 4232 5800 7994 11129 14577 16458 17242 17242

784 1489 2194 2743 3762 5016 7210 8778 10972 12540

1”

3/4”

1/2”

3/8”

1/4”

pipe size 11/2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08

Inlet pressure (psi)

11/4” 30

30

10

10

10

10

5 10 15 25 40 60 80 100 125

9405 15674 20377

8307 14577 18809 22728

6427 11129 13793 17242 21160 23512

4232 7367 9718 13480 17242 21160 23512 25079

2665 4546 5956 8151 11129 15674 18809 18809 18809

1411 2194 2665 3762 5016 7210 8778 10972 12540

1”

3/4”

1/2”

3/8”

1/4”

Victor/F.w. Webb can provide customized training for your company! Just ask your victor sales person.

16

Gas Equipment Catalog

victormfg.com


SECTION

1

Regulators Model 243 Capacity Tables

(continued)

1

Natural Gas Chart

orifice size and valve angle pipe size 2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05

orifice size and valve angle

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

1/4”

30

30

30

10

10

10

10

1 2 5 10 15 25 40 60 80 100 125

3400 5600 10500 13000 14000

3000 4700 9000 13000 14000 15000

2100 3700 7800 12000 15000 20000 20000

1950 3400 6900 9200 10500 12000 14500 15500

1150 2000 3500 5500 7000 500 12500 13000 14000 14000

750 1200 2100 3200 4000 5300 7500 10000 12000 12000 12000

400 600 1000 1600 1800 2400 3200 4400 5600 7000 8000

pipe size 2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

30

30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

6500 8000 9000 12000

5000 7500 8500 11000 13500

4000 6000 8000 10000 12500 14000

4000 6000 8000 10000 11500 13000 15000

2000 4000 5500 7000 9500 11000 13500 15000 16000

1300 2200 3000 4000 5500 7400 10000 13000 14000 14000

500 1000 1400 1800 2400 3300 4500 6000 7000 8500

1/4”

Propane Gas Chart

2” Model 243-12-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle pipe size 2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05

orifice size and valve angle

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

1/4”

30

30

30

10

10

10

10

1 2 5 10 15 25 40 60 80 100 125

5329 8778 16458 20377 21944

4702 7367 14107 20377 21944 23512

3292 5800 12226 18809 23512 31349 31349

3057 5329 10815 14420 16458 18809 22728 24295

1803 3135 5486 8621 10972 784 19593 20377 21944 21944

1176 1881 3292 5016 6270 8307 11756 15674 18809 18809 18809

627 940 1567 2508 2821 3762 5016 6897 8778 10972 12540

pipe size 2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

30

30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

10188 12540 14107 18809

7837 11756 13323 17242 21160

6270 9405 12540 15674 19593 21944

6270 9405 12540 15674 18026 20377 23512

3135 6270 8621 10972 14891 17242 21160 23512 25079

2038 3448 4702 6270 8621 11599 15674 20377 21944 21944

784 1567 2194 2821 3762 5173 7053 9405 10972 13323

1/4”

Victor/F.w. Webb can help you layout a petite 7 base board system.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

17

regulators & accessories

2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)


SECTION

1

Regulators Model 243 Capacity Tables

(continued)

Natural Gas Chart

11/4” Model 243-8-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size 11/4” Set Point 11” wc. 2” wc Droop Green Spring 6” to 14” wc 143-82-021-02

Inlet pressure (psi)

3/4”

10

10

1 2 5 10 15 25 40 60 80 100 125

1150 1850 2500 2900 3700 4250 5300

1000 1350 2200 2700 2950 4000 4200 4850 5850

1/2”

3/8”

1/4”

0.207”

10

10

10

650 1000 1750 2450 2600 3300 3800 4400 5600 6000

300 450 800 1300 1700 2400 3200 4400 5600 7000 8000

350 550 900 1100 1500 2100 2900 3700 4500 5600

orifice size and valve angle pipe size

11/4” Set Point 1” psi Droop Orange Spring 1 to 2 psi 143-16-021-06

Inlet pressure (psi)

3/4”

10

10

2 5 10 15 25 40 60 80 100 125

1850 2100 2700 3150 4150 5300

1150 1700 2000 3100 3250 3800 4600 4650

1/2”

3/8”

1/4”

0.207”

10

10

10

850 1350 1950 2050 2850 3600 4250 5600 6000

450 750 1300 1700 2400 3200 4400 5600 7000 8000

500 800 1000 1500 2100 2900 3700 4500 5600

Propane Gas Chart

11/4” Model 243-8-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle pipe size 11/4” Set Point 11” wc. 2” wc Droop Green Spring 6” to 14” wc 143-82-021-02

18

Inlet pressure (psi)

3/4”

1/2”

3/8”

1/4”

0.207”

10

10

10

10

10

1 2 5 10 15 25 40 60 80 100 125

1803 2900 3919 4546 5800 6662 8307

1567 2116 3448 4232 4624 6270 6583 7602 9170

1019 1567 2743 3840 4075 5173 5956 6897 8778 9405

470 705 1254 2038 2665 3762 5016 6897 8778 10972 12540

549 862 1411 1724 2351 3292 4546 5800 7053 8778

Gas Equipment Catalog

orifice size and valve angle pipe size

11/4” Set Point 1” psi Droop Orange Spring 1 to 2 psi 143-16-021-06

Inlet pressure (psi)

3/4”

1/2”

3/8”

1/4”

0.207”

10

10

10

10

10

2 5 10 15 25 40 60 80 100 125

2900 3292 4232 4937 6505 8307

1803 2665 3135 4859 5094 5956 7210 7289

1332 2116 3057 3213 4467 5643 6662 8778 9405

705 1176 2038 2665 3762 5016 6897 8778 10972 12540

784 1254 1567 2351 3292 4546 5800 7053 8778

victormfg.com


SECTION

1

Regulators Model 243 Capacity Tables

(continued)

1

Natural Gas Chart

orifice size and valve angle pipe size 2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07

orifice size and valve angle

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

1/4”

30

30

30

10

10

10

10

2 5 10 15 25 40 60 80 100 125

3350 6600 11000 13000

3000 5900 10000 12000 15000

2000 4200 7600 9300 16500 20000

1900 3900 6500 8300 11000 14000 15500

1200 2400 4100 5600 8500 12500 13000 14000 14000

1000 1600 2800 3800 5300 7500 10000 12000 12000 12000

500 1000 1450 1700 2400 3400 4400 5600 7000 8000

pipe size 2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

30

30

30

10

10

10

10

5 10 15 25 40 60 80 100 125

8200 12500 15500

7400 11300 14500 18000

5200 8700 11500 16500 20000

4800 7800 10000 13500 16500 16500

2900 4800 6500 9000 12500 15500 16000 16000

1900 3000 3800 5300 7600 10000 12000 12000 12000

900 1400 1700 2400 3400 4600 5600 7000 8000

1/4”

Propane Gas Chart

2” Model 243-12-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle pipe size 2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07

orifice size and valve angle

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

1/4”

30

30

30

10

10

10

10

pipe size

2 5 10 15 25 40 60 80 100 125

5251 10345 17242 20377

4702 9248 15674 18809 23512

3135 6583 11913 14577 25863 31349

2978 6113 10188 13010 17242 21944 24295

1881 3762 6427 8778 13323 19593 20377 21944 21944

1567 2508 4389 5956 8307 11756 15674 18809 18809 18809

784 1567 2273 2665 3762 5329 6897 8778 10972 12540

2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08

Inlet pressure (psi)

11/4”

1”

3/4”

3/4”

1/2”

3/8”

30

30

30

10

10

10

10

5 10 15 25 40 60 80 100 125

12853 19593 24295

11599 17712 22728 28214

8151 13637 18026 25863 31349

7524 12226 15674 21160 25863 25863

4546 7524 10188 14107 19593 24295 25079 25079

2978 4702 5956 8307 11913 15674 18809 18809 18809

1411 2194 2665 3762 5329 7210 8778 10972 12540

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

1/4”

19

regulators & accessories

2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)


SECTION

1

Regulators Model 243 Capacity Tables

(continued)

Natural Gas Chart

2” and 11/2” Model 243-8-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size

2” and 11/2” Set Point 11” w.c. 2” w.c. Droop Green Spring 6” to 14” w.c. 143-82-021-02

Inlet pressure (psi) 1 2 5 10 15 25 40 60 80 100 125

orifice size and valve angle

1”

3/4”

1/2”

3/8”

1/4”

0.207

30

10

10

10

10

10

1650 2700 4800 7000 9000 11000

1150 2000 3800 5400 7400 8800 11000

1000 1400 2600 4200 5500 7500 9600 11000 11500

650 1000 1750 2800 3600 5100 7100 9300 10500 11000

300 450 900 1300 1700 2400 3200 4400 5600 7000 8000

350 600 900 1100 1500 2100 2900 3700 4500 5600

pipe size

11/2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06

Inlet pressure (psi) 2 5 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

1/4”

0.207

30

10

10

10

10

10

2100 4000 6500 8400 11000

1650 3200 5200 6500 11000

1200 2100 3100 4400 6500 8600 10500 11500

850 1300 2200 3000 4400 6700 9000 10500 11000

450 850 1300 1700 2400 3200 4400 5600 7000 8000

550 800 1000 1500 2100 2900 3700 4500 5600

orifice size and valve angle pipe size

2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06

Inlet pressure (psi) 2 5 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

1/4”

30

10

10

10

10

10

2400 4000 7000 11000 14500

1800 3400 6000 9000 15000 17500

1700 3300 5400 7000 10000 12000

1200 2200 3500 4600 7400 10500 11000

850 1300 2200 3100 4800 7000 9500 10500 11000

450 900 1400 1700 2400 3400 4600 5600 7000 8000

0.207

Propane Gas Chart*

2” and 11/2” Model 243-8-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle pipe size

2” and 11/2” Set Point 11” w.c. 2” w.c. Droop Green Spring 6” to 14” w.c. 143-82-021-02

Inlet pressure (psi) 1 2 5 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

orifice size and valve angle

1/4”

0.207 10

30

10

10

10

10

2586 4232 7524 10972 14107 17242

1803 3135 5956 8464 11599 13793 17242

1567 2194 4075 6583 8621 11756 15047 17242 18026

1019 1567 2743 4389 5643 7994 11129 14577 16458 17242

470 705 1411 2038 2665 3762 5016 6897 8778 10972 12540

549 940 1411 1724 2351 3292 4546 5800 7053 8778

pipe size

11/2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06

2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06

20

Gas Equipment Catalog

2 5 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

1/4”

0.207

30

10

10

10

10

10

3292 6270 10188 13166 17242

2586 5016 8151 10188 13480 17242

1881 3292 4859 6897 10188 13480 16458 18026

1332 2038 3448 4702 6897 10502 14107 16458 17242

705 1332 2038 2665 3762 5016 6897 8778 10972 12540

862 1254 1567 2351 3292 4546 5800 7053 8778

orifice size and valve angle pipe size

* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

Inlet pressure (psi)

Inlet pressure (psi) 2 5 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

1/4”

30

10

10

10

10

10

3762 6270 10970 17242 22728

2821 5329 9405 14107 23512 27430

2665 5173 8484 10972 15674 18809

1881 3448 5486 7210 11599 16458 19593 21160

1332 2038 3448 4859 7524 10972 14891 16458 17242

705 1411 2194 2665 3762 5329 7210 8778 10972 1250

0.207

victormfg.com


SECTION

1

Regulators Model 243 High Pressure Capacity Tables

Natural Gas Chart

(0.6 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle

*

pipe size 11/4”

Set Point 5 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08

Inlet pressure (psi)

3/4”

1/2”

3/8”

1/4”

10

10

10

10

10 15 25 40 60 80 100 125

3300 3400 4400 5800

2050 3100 3650 3800 4400 4500

2000 2200 3050 3200 4100 5300 6000

1300 1700 2400 3200 4400 5600 7000 8000

orifice size and valve angle

*

pipe size 11/2”

Set Point 5 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08

Inlet pressure (psi) 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

30

10

10

10

10

6000 8600 12000

5500 6500 9300 12000

3200 4400 6100 8500 10000 11000

2300 3200 4800 6100 8700 10000 11000

1300 1700 2400 3200 4400 5600 7000 8000

1/4”

orifice size and valve angle pipe size 2” Set Point 5 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08

Inlet pressure (psi) 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

30

10

10

10

10

6000 8600 13000

5500 6500 8200 12000

3200 4400 6100 8700 10000 11500

2400 3200 4800 6100 8700 10000 11000

1300 1700 2400 3400 4600 5600 7000 8000

1/4”

Propane Gas Chart**

11/4”, 11/2”, 2” Models 243-8HP Capacity Table in 1000’s of BTU’s Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

orifice size and valve angle

*

pipe size 11/4”

Set Point 5 psi 1 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08

Inlet pressure (psi)

3/4”

10

10

10

10

10 15 25 40 60 80 100 125

5173 5329 6897 9091

3213 4859 5721 5956 6897 7053

3135 3448 4781 5016 6427 8307 9405

2038 2665 3762 5016 6897 8778 10972 12540

1/2”

3/8”

orifice size and valve angle

1/4”

*

pipe size 11/2”

Set Point 5 psi 1 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08

Inlet pressure (psi) 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

1/4”

30

10

10

10

10

9405 13480 18809

8621 10188 14577 18809

5016 6897 9561 13323 15674 17242

3605 5016 7524 9561 13637 15674 17242

2038 2665 3762 5016 6897 8778 10972 12540

orifice size and valve angle pipe size 2” Set Point 5 psi 1psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08

Inlet pressure (psi) 10 15 25 40 60 80 100 125

1”

3/4”

1/2”

3/8”

30

10

10

10

10

9405 13480 20377

8621 9405 12853 18809

5016 6897 9561 13637 15674 17242

3762 5016 7524 9561 13637 15674 17242

2038 2665 3762 5329 7210 8778 10972 12540

1/4”

* Special Order ** Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

21

regulators & accessories

11/4”, 11/2”, 2” Models 243-8HP Capacity Table in SCFH of Natural Gas

1


SECTION

1

Regulators Gas Appliance Pressure Regulators

Maxitrol Company manufactures a complete line of gas appliance regulators for domestic, commercial, and industrial needs.

Balance Valve Design — 210D, E & G Main burner and pilot applications. The balanced valve 210 Series are designed for use with intermediate pressure. The balancing diaphragm virtually eliminates inlet pressure effect, which makes them ideal for applications where supply pressure fluctuates.

210D, E & G

MFR#

pipe sizes

capacities to

210D 210E 210G

1”, 11/4”, 11/2”, 2”, 21/2”, & 3”

6500 CFH 12000 CFH 26000 CFH

inlet pressures to

outlet pressures

10 psi (700 mbar)

1.0” to 42” w.c. (2.5 to 105 mbar)

MFR#

body sizes

Qty. per case

webb#

210D-1

1”

4

201676

210D-1010-114

11/4”

4

201679

210D-112

11/2”

4

201678

210D-36-24

11/2”

4

199526

210D412-24

11/2”

4

2”

2

198116

210E412-24

11/2”

2

201673

210E412-32

2”

2

201674

210E-2

Natural Gas Chart

11/2” & 2” Stock Spring Violet 4-12” w.c. Model 210E Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)

22

Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

11/2”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

4450 6300 7000 7000 7000 7000 7000 7000 7000 7000

3650 5750 7500 8800 8800 8800 8800 8800 8800 8800

2550 5150 7050 8500 8500 8500 8500 8500 8500 8500

4050 6300 7950 10450 10500 10500 10500 10500 10500

5450 7250 9950 10500 10500 10500 10500 10500

4050 6300 9250 10500 10500 10500 10500 10500

Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

2”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

5150 7250 8000 8000 8000 8000 8000 8000 8000 8000

4200 6650 8650 10000 10000 10000 10000 10000 10000 10000

2950 5950 8150 9850 10000 10000 10000 10000 10000 10000

4700 7250 9150 12000 12000 12000 12000 12000 12000

6300 8400 11500 12000 12000 12000 12000 12000

4700 7250 10700 12000 12000 12000 12000 12000

Gas Equipment Catalog

victormfg.com


SECTION

1

Regulators Gas Appliance Pressure Regulators

(continued)

Propane Gas Chart*

(1.5 Specific Gravity — 14.65 psia — 60°F) Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

11/2”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

6975 9875 10972 10972 10972 10972 10972 10972 10972 10972

5721 9013 11756 13793 13793 13793 13793 13793 13793 13793

3997 8072 11050 13323 13793 13793 13793 13793 13793 13793

6348 9875 12461 16380 16458 16458 16458 16458 16458

8543 11364 15596 16458 16458 16458 16458 16458

6348 9875 14499 16458 16458 16458 16458 16458

Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

8” w.c. 8072 6583 4624 .5 psi 11364 10423 9326 7367 .75 psi 12540 13558 12775 11364 9875 1 psi 12540 15674 15439 1432 13166 1.5 psi 12540 15674 15674 18809 18026 2” 2 psi 12540 15674 15674 18809 18809 3 psi 12540 15674 15674 18809 18809 5 psi 12540 15674 15674 18809 18809 7.5 psi 12540 15674 15674 18809 18809 10 psi 12540 15674 15674 18809 18809 * Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

7367 11364 16772 18809 18809 18809 18809 18809

Natural Gas Chart

1” & 11/4” Stock Spring Violet 4-12” w.c. Model 210D Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

1”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

2400 3400 3500 3500 3500 3500 3500 3500 3500 3500

1900 3100 4000 4000 4000 4000 4000 4000 4000 4000

1300 2700 3800 4500 4500 4500 4500 4500 4500 4500

2200 3400 4300 4800 4800 4800 4800 4800 4800

2900 3900 4800 4800 4800 4800 4800 4800

2200 3400 5000 5000 5000 5000 5000 5000

Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

11/4”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

3000 4000 4000 4000 4000 4000 4000 4000 4000 4000

2400 3905 5000 5000 5000 5000 5000 5000 5000 5000

1700 3400 4700 5000 5000 5000 5000 5000 5000 5000

2700 4200 5300 6000 6000 6000 6000 6000 6000

3700 4900 6000 6000 6000 6000 6000 6000

2700 4200 6000 6000 6000 6000 6000 6000

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

23

1 regulators & accessories

11/2” and 2” Stock Spring Violet 4-12” w.c. Model 120E Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas


SECTION

1

Regulators Gas Appliance Pressure Regulators

(continued)

Natural Gas Chart

11/2” Stock Spring Violet 4-12” w.c. Model 210D Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

11/2”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

3100 4000 4000 4000 4000 4000 4000 4000 4000 4000

2500 4000 5000 5000 5000 5000 5000 5000 5000 5000

1800 3600 5000 5000 5000 5000 5000 5000 5000 5000

2800 4400 5600 6000 6000 6000 6000 6000 6000

3800 5100 6000 6000 6000 6000 6000 6000

2800 4400 6500 6500 6500 6500 6500 6500

Propane Gas Chart*

1”, 11/4” and 11/2” Stock Spring Violet 4-12” w.c. Model 210D Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F) Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

1”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

3762 5329 5486 5486 5486 5486 5486 5486 5486 5486

2978 4859 6270 6270 6270 6270 6270 6270 6270 6270

2038 4232 5956 7053 7053 7053 7053 7053 7053 7053

3448 5329 6740 7524 7524 7524 7524 7524 7524

4546 6113 7524 7524 7524 7524 7524 7524

3448 5329 7837 7837 7837 7837 7837 7837

Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

11/4”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

4702 6270 6270 6270 6270 6270 6270 6270 6270 6270

3762 6121 7837 7837 7837 7837 7837 7837 7837 7837

2665 5329 7837 7837 7837 7837 7837 7837 7837 7837

4232 6583 8307 9405 9405 9405 9405 9405 9405

5800 7080 9405 9405 9405 9405 9405 9405

4232 6583 9405 9405 9405 9405 9405 9405

Pipe size

Inlet pressure (psi)

Set point 2” w.c.

Set point 4” w.c.

Set point 6” w.c.

Set point 9” w.c.

Set point 12” w.c.

Set point 16” w.c.

11/2”

8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi

4869 6270 6270 6270 6270 6270 6270 6270 6270 6270

3919 6270 7837 7837 7837 7837 7837 7837 7837 7837

2821 5643 7837 7837 7837 7837 7837 7837 7837 7837

4389 6897 8778 9405 9405 9405 9405 9405 9405

5956 7994 9405 9405 9405 9405 9405 9405

4389 6897 10188 10188 10188 10188 10188 10188

* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

24

Gas Equipment Catalog

victormfg.com


SECTION

1

Regulators Straight-Thru-Flow-Design RV52, RV53, RV61, RV81, RV91, RV111, RV131 1/2”, 3/4”, 11/4”, 11/2”, 2”, 21/2”, 3”, & 4” Main burner only

1

RV52 & RV53

RV61

RV81 & RV91

MFR#

pipe sizes

capacities to

RV52 RV53 RV61 RV81 RV91 RV111 RV131

1/2” & 3/4”

900 CFH 130 CFH 2500 CFH 4500 CFH 7500 CFH 1 psi 2 psi

3/4” & 1”

1” & 11/4” 11/4”, 11/2”, 2” & 21/2” 21/2” & 3” 4” Flanged

MFR#

RV111

RV131

outlet pressures

1/2 psi (35 mbar)

1.0” to 12” w.c.

1 psi (70 mbr)

1.0” to 22” w.c.

2 psi (140 mbr)

3.0” to 42” w.c.

body sizes

Qty. per case

webb#

RV52-12

1/2”

25

108537

RV52-34

3/4”

25

196920

RV53-1

1”

25

118670

RV53-34

3/4”

25

108742

RV61-1

Natural Gas Chart

inlet pressures to

1”

18

185908

RV61-114

11/4”

18

188934

RV81-114

11/4”

4

196848

2”

4

109623

RV91-2

Straight thru flow RV regulator (Appliance or combustion regulators) Capacity Table in CFH’s of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) MFR#

Pipe size

rv52 rv53 rv61 rv81 rv91 rv111 rv131

1/2” or 3/4”

3/4” or 1” 1” or 11/4” 11/4” or 11/2” 2” or 21/2” 21/2” or 3” 4”

Pressure drop in w.c.

CSA Max

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

2

3

4

450 710 1100 2500 3275 7500 —

151 217 379 780 1212 2742 4734

214 306 536 1102 1714 3878 6695

362 375 675 1350 2100 4750 8200

302 433 759 1559 2424 5485 9468

338 484 848 1743 2711 6718 11596

370 530 929 1909 2969 6718 11596

400 573 1004 2062 3208 7256 12390

427 612 1073 2204 3429 7757 13390

453 650 1138 2339 3637 8227 13390

478 684 1200 2465 3834 8572 14971

676 968 1742 3465 5422 14134 21172

828 1185 2134 4269 6640 14862 25930

956 1369 2464 4929 7668 17161 29942

Propane Gas Chart*

Straight thru flow RV regulator (Appliance or combustion regulators) Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F) MFR#

Pipe size

CSA Max

Pressure drop in w.c. 0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1/2” or 3/4” 705 237 335 411 473 530 580 627 669 710 749 rv52 rv53 3/4” or 1” 1113 340 480 588 679 759 831 898 959 1019 1072 rv61 1” or 11/4” 1724 594 840 1058 1190 1329 1456 1574 1682 1784 1881 rv81 11/4” or 11/2” 3919 1223 1727 2116 2444 2732 2992 3232 3455 3666 3864 rv91 2” or 21/2” 5133 1900 2687 3292 3799 4249 4654 5028 5375 5701 6010 rv111 21/2” or 3” 11756 4298 6079 7445 8597 9612 10530 11373 12159 12895 13436 rv131 4” — 7420 10494 12853 14841 16593 18176 19632 20988 22261 23466 * Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

2

3

4

1060 1517 2730 5463 8499 22154 33186

1298 1857 3345 6691 10408 23295 40644

1498 2146 3862 7726 12019 26899 46932

25

regulators & accessories

The straight-thru-flow RV Series, size for size, has the highest pressure drop capacity of any regulator design available. They are best used when supply pressure is low enough to cause concern about capacity. Gases: Natural, manufactured, mixed, liquified petroleum, or LP gas-air mixture. Features: • Greater accuracy — higher pressure drop capacity. • Outlet pressure available to 42” w.c. • Available in full range of pipe sizes from 1/2” to 4”. • All models tapped with NPT vent bosses. • A.G.A. Rated (except RV131) — 1/2 psi (35 mbar).


SECTION

1

Regulators 325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators

Features: • CSA certified for up to 5-psi inlet pressure. • Over-pressure protection device (OPD) to limit downstream pressure in case of regulator failure. • Maxitrol OPD approved and tested with the regulator. • Regulators or OPD’s can be ordered as separate items — or as a factory assembled unit. • Self-aligning valve with lever action for dead end regulator lockup. • Optional vent limiter eliminates the need to run vent piping to an outside area. Benefits: • Meets new ANSI standard Z21-80 for line pressure regulators — for use on piping systems such as CSST or semi-rigid copper tubing up to 5-psi. • OPD provides required downstream over-pressure protection for supply pressures in excess of 2-psi. • Pounds to inches regulator provides precise control from pilot flows to full regulator capacity. • Meets many utility specifications.

325-5ALX Outlet Pressure Range (all models) Certified spring – 7-11 in w.c.

7” WC Less Vent Limiter

Attention: To comply with

body sizes

Qty. per case

webb#

325-3L-12

1/2”

50

252139

325-3L-38

3/8”

50

252138

325-5AL-1

1”

18

252142

325-5AL-12

1/2”

18

252140

325-5AL-34

3/4”

18

252141

325-7AL-114

11/4”

4

224151

325-7AL-112

11/2”

4

224152

MFR#

the ANSI Z21-80 Standard for Line Pressure Regulators, installations exceeding 2-psi nominal require a tested and approved over-pressure protection device (OPD) for use with the regulator. (Over-pressure protection is not required for supply pressures up to and including 2-psi.)

11” WC With Vent Limiter MFR#

Description

MXT325-3L-38LP MXT325-3L-12LP MXT325-5AL-12LP MXT325-5AL-34LP MXT325-5AL-1LP MXT325-7AL-114LP

Accessories Vent Limiting Means

Special Order For 325 Series With OPD

MXT325-7AL-112LP

webb#

LP REG 3/8" IPS AT 11"WC W/ VNT LIMITER LP REG 1/2" IPS AT 11"WC W/ VNT LIMITER

432833 432832

LP REG 1/2" IPS AT 11"WC W/VNT LIMITER

LP REG 3/4" IPS AT 11"WC W/ VNT LIMITER LP REG 1" IPS AT 11"WC W/ VNT LIMITER

432834 432836 432835

LP REG 1-1/4" IPS AT 11"WC W/VNT LIMITER LP REG 1-1/2" IPS AT 11"WC W/VNT LIMITER

432838 432837

Ball check permits free inhalation for fast regulator diaphragm response on opening cycle, but limits gas escapement to within ANSI standards should a diaphragm rupture. MFR#

Description

12A04

Optional Automatic Vent Limiting Device for RV48, RV52, RV53, RV61

77527

12A06

192793

12A49

Optional Vent Limiting Orifice for RV48, RV52, RV53, RV61 Optional Automatic Vent Limiting Device for 325-3, 325-3L, 325-3LX, OPD48, OPD600, 325-3L47 (reg. only), 325-3L48 (reg. & OPD), 325-5AL48 (OPD only), 325-5AL600 (OPD only) Optional Automatic Vent Limiting Device for 325-5A, 325-5AL, 325-ALX, 325-5AL48 (reg. only), 325-5AL600 (reg. only) Optional Automatic Vent Limiting Device for 325-7L, 325-7AL

13A15

Outdoor Vent Protector for 3L and 5AL

246350

13A25

Outdoor Vent Protector for 3L and 5AL

433028

12A09 12A39

Vent Limiter 12A09

webb#

109780 192794 436746

Natural Gas Chart

Model 325L Series 2 PSI Max Inlet Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) MFR# 325-3L

Pipe size 3/8” or 1/2”

325-5AL

1/2”

325-5AL

3/4” or 1”

325-7AL

11/4” or 11/2”

26

outlet pressure

1/2 PSI

3/4 PSI

Inlet

1 PSI Inlet

11/2 PSI Inlet

2 PSI Inlet

Max Load Multiple appliances

max individual appliance load

7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.

145 110 335 250 335 250 690 520

200 180 425 420 475 420 970 860

250 230 425 425 550 535 1000 1000

250 250 425 425 550 550 1000 1000

250 250 425 425 550 550 1000 1000

250 250 425 425 550 550 1000 1000

140 140 300 300 300 300 900 900

Inlet

Gas Equipment Catalog

victormfg.com


SECTION

1

Regulators 325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators

1

Propane Gas Chart*

Model 325L Series 2 PSI Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas

MFR# 325-3l

Pipe size 3/8” or 1/2”

325-5al

1/2”

325-5al

3/4” or 1”

325-7l

11/4” or 11/2”

outlet pressure

1/2 PSI

3/4 PSI

Inlet

1 PSI Inlet

11/2 PSI Inlet

2 PSI Inlet

Max Load Multiple appliances

max individual appliance load

7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.

227 172 525 392 525 392 1082 815

313 282 666 658 745 658 1520 1348

392 361 666 666 862 839 1567 1567

392 392 666 666 862 862 1567 1567

392 392 666 666 862 862 1567 1567

392 397 666 666 862 862 1567 1567

219 219 470 470 470 470 1410 1410

Inlet

* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

Natural Gas Chart

Model 325 With OPD Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)

MFR#

Pipe size

325-3l47

3/8”

325-3l47

1/2”

325-3l48

1/2”

325-5al48

1/2”

325-5al48

3/4”

325-5al600

3/4”

325-5al600

1”

outlet pressure

1/2 PSI

3/4 PSI

Inlet

1 PSI Inlet

5 PSI Inlet

Max Load Multiple appliances

max individual appliance load

7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.

125 100 125 105 160 120 235 235 320 245 345 260 375 285

125 125 125 125 200 200 235 235 320 320 425 425 465 465

125 125 125 125 200 200 235 235 320 320 425 425 465 465

125 125 125 125 200 200 235 235 320 320 425 425 465 465

125 125 125 125 200 200 235 235 320 320 425 425 465 465

125 125 125 125 200 200 235 235 320 320 425 425 465 465

Inlet

Propane Gas Chart*

Model 325 with OPD Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)

MFR#

Pipe size

325-3l47

3/8”

325-3l47

1/2”

325-3l48

1/2”

325-5al48

1/2”

325-5al48

3/4”

325-5al600

3/4”

325-5al600

1”

outlet pressure

1/2 PSI

3/4 PSI

Inlet

1 PSI Inlet

5 PSI Inlet

Max Load Multiple appliances

max individual appliance load

7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.

196 157 196 165 251 188 368 368 502 384 541 408 588 447

196 196 196 196 313 313 368 368 502 502 666 666 729 729

196 196 196 196 313 313 368 368 502 502 666 666 729 729

196 196 196 196 313 313 368 368 502 502 666 666 729 729

196 196 196 196 313 313 368 368 502 502 666 666 729 729

196 196 196 196 313 313 368 368 502 502 666 666 729 729

Inlet

* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

27

regulators & accessories

(1.5 Specific Gravity — 14.65 psia — 60°F)


SECTION

1

Regulators Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48 Main burner and pilot applications MFR#

pipe sizes

capacities to

1/8”

1/2” & 3/4”

25 CFH 65 CFH 125 CFH 250 CFH

RV12 RV20 RV47 & CV47 RV48

RV12

1/4” & 3/8” 3/8” & 1/2”

MFR#

RV20

RV47 & CV47

RV48

inlet pressures to 1/2 psi (35 mbar) 1/2 psi

1/2 psi (35 mbr)

body sizes

Qty. per case

webb#

RV20L-38

3/8”

100

185902

RV47CL-12

1/2”

50

185903

RV47CL-38

3/8”

50

188932

RV47L-12

1/2”

50

197256

RV47L-38

3/8”

50

188933

RV48CL-12

1/2”

50

185905

RV48CL-34

3/4”

50

185904

RV48L-12

1/2”

50

185907

RV48L-34

3/4”

50

185906

body sizes

Qty. per case

STD. SPRING

SET POINT

webb#

RV20L-38

3/8"

100

3-5" wc

4"

185902

RV48CL-12

1/2"

50

None

fixed 4 or 10"

185903

RV47CL-38

3/8"

50

None

fixed 4 or 10"

188932

RV47L-12

1/2"

50

4-12"

11"

197256

RV47L-38

3/8"

50

4-12"

11"

188933

RV48CL-12

1/2"

50

None

fixed 4 or 10"

185905

RV48CL-34

3/4"

50

None

fixed 4 or 10"

185904

RV48L-12

1/2"

50

4-12"

11"

185907

RV48L-34

3/4"

50

4-12"

11"

185906

RV48-12

1/2"

50

3-6"

4"

77528

RV48-34

3/4"

50

3-6"

4"

77529

MFR#

outlet pressures 1.0” to 12” w.c.

Natural Gas Chart

Poppet RV Regulator (Appliance Regulators) Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) (Min. Capacity on all models is 150 btu/hr)

MFR# rv12 rv20 rv47 rv47c rv48 rv48 rv48c rv48c

28

Pipe size 1/8”

1/4” or 3/8” 3/8” or 1/2” 3/8” or 1/2” 1/2” 3/4” 1/2” 3/4”

max capacity at .3” w.c. Pressure drop

Suggested Max Supply for Main burner only

Suggested Max Supply for Main burner only and Pilot

max individual load with fixed orifice vent limiter

max individual load with ball check vent limiter

15 30 30 60 130 150 130 150

30 65 125 125 230 230 400 400

25 50 90 125 230 250 275 275

20 30 40 40 40 40 40 40

— — 90 125 160 160 160 160

Gas Equipment Catalog

victormfg.com


SECTION

1

Regulators

Propane Gas Chart*

Poppet RV Regulator (Appliance Regulators) Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas

MFR#

Suggested Max Supply for Main burner only

Suggested Max Supply for Main burner only and Pilot

max individual load with fixed orifice vent limiter

max individual load with ball check vent limiter —

Pipe size

max capacity at .3” w.c. Pressure drop

1/8”

23

47

39

31

47

102

78

47

3/8” or 1/2”

47

196

141

63

141

94

196

196

63

196

1/2”

204

361

361

63

251

235

361

392

63

251

204

627

392

63

251

235

627

392

63

251

rv12 rv20 rv47 rv47c rv48 rv48 rv48c rv48c

1/4” or 3/8” 3/8” or 1/2” 3/4” 1/2” 3/4”

* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.

Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48 DESCRIPTION

USE WITH REGULATOR

WEBB #

MXTR325C10-1022

MFR#

Spring Red 10-22 325-3

325-3

185891

MXTR325C10-1530

Spring Yellow 15-30 325C

325-3

197075

MXT325E-10A-1022

Spring Red 10-22” 325-5A

325-5A

110108

MXTR325E10-26A

Springs 2 to 6 lbs

325-5A

309740

MXTR325E10-412

Spring Violet 4-12

325-5A

185893

MXTR325E10-P12

Spring Tagged

325-5A

185894

MXTR4810-512

Spring Blue 5-12 RV48

RV48

185889

MXTR6110-1022

Maxitrol Spring 10 to 12

RV61

254238

MXTR8110-1022

Spring Red

RV81/210D

192815

MXTR8110-1530

Spring Yellow 15-30 210D

RV81/210D

196945

MXTR8110-2042

Spring Black 20-42

RV81/210D

185897

MXTR8110-412

Spring Violet 4-12 RV

RV81/210D

196956

MXTR8110-512

Spring Blue 5-12

RV81/210D

185898

MXTR8110-515

Spring Green 5-15 RV881 210

RV81/210D

196987

MXTR9110-1022

Spring Red 10-22

RV91/210E

185899

MXTR9110-1530

Spring Yellow 15-30” 210E

RV91/210E

196947

MXTR9110-412

Spring Violet 4-12” Spring

RV91/210E

199275

MXTR9110-512

Spring Blue 5-12

RV91/210E

309737

Victor/F.w. Webb offers webbConnect! you can order, check current pricing and inventory 24/7!

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

29

regulators & accessories

(1.5 Specific Gravity — 14.65 psia — 60°F)

1


SECTION

2

Cylinder & Service Valves Cylinder Valve for RV and Small ASME System Vapor Withdrawal

Designed especially for vapor withdrawal service in small ASME containers with surface area up to 23.8 square feet. UL flow capacity is 645 CFM/air, per NFPA 58.

MFR#

9106CO

9106CO

FIXED LIQUID PresSure LEVEL relief container Service VENT VALVE valve connection Connection STYLE setting 3/4” M. NPT

F. POL CGA 510

None

for use in cylinders with propane capacity up to

312 PSIG

flow capacity SCFM/AIR Webb#

ASME Tanks*

645

186998

* Surface area up to 23.8 square feet.

Cavagna OPD Valve

VCT80-8169

Type 1 valves intended for DOT cylinders up to 40 lbs. LP Gas capacity. This valve has a vapor service outlet, relief valve, captive fixed liquid level gauge, and an overfill prevention device. Type 1 ACME and POL Outlet thread: 4.0 inches Dip tube length: 375 PSI Setting pressure: No Flow limiter: No Plastic cap: Inlet thread: 3/4 Pressure relief valve: Yes Gas type: LP-Gas Packaging: 28 Availability: Yes MFR#

size

Webb#

VCT80-8169

20#

395314

VCT80-9-890-8128

30#

401280

VCT80-9-890-8185

40#

399370

Heavy Duty Cylinder Valves for Vapor Withdrawal This heavy duty cylinder valve is designed for vapor withdrawal of DOT cylinders up to 100 lbs. propane capacity. It is used in domestic hookups, with RV’s and as a heavy duty barbeque cylinder valve.

MFR#

9103D11.6

9103D10.6 9103D11.6

CONTAINER CONNECTION

Service CONNECTION

FIXED LIQUID LEVEL VENT VALVE STYLE

3/4” M. NPT

F. POL CGA 510

Knurled

DIP TUBE PresSure LENGTH relief WITH valve DEFLECTOR setting 10.6” 11.6”

for use in cylinders with propane capacity up to

375 PSIG

100 lbs.

approximate filling rate liquid flow, gpm pressure drop across valves MFR# 9103D10.6 9103D11.6

30

accessories

10 PSIG

25 PSIG

50 PSIG

100 PSIG

POL PLUG

12.7

20.3

29.0

41.3

N970P

Gas Equipment Catalog

Webb# 162726 162727

victormfg.com


SECTION

2

Cylinder & Service Valves Cylinder Valve for Liquid Withdrawal Equipped with excess flow valves and liquid withdrawal tubes, they are designed for liquid withdrawal of DOT cylinders up to 100 lbs. propane capacity. They are most often used with heavy BTU loads found in industrial uses. MFR#

CONTAINER CONNECTION

Service CONNECTION

FIXED LIQUID LEVEL VENT VALVE STYLE

DIP TUBE LENGTH WITH DEFLECTOR

liquid withdrawAl tube length

3/4” M. NPT

CGA 555

Knurled

11.6”

44”

9107K8A

MFR#

9107K8A With Dip Tube

Pressure relief valve setting

For use in cylinders with propane capacity up to

10 psig

375 PSIG

100 lbs.

3.3

9107K8A

closing flow (LP-Gas)*

Pressure drop across valves

vapor

25 50 100 25 psig psig psig psig inlet 5.4

7.7

100 psig inlet

525 SCFH

11.1

liquid Webb#

1,000 SCFH

1.7 GPM

162728

* Closing flows based on 3/8” O.D. withdrawal tube 44” long or less attached. IMPORTANT: 1/4” O.D. pigtails or POL connections for 1/4” O.D. pigtails should not be used with these valves. NOTES: To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use. These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

“Dual” Cylinder Valve for Simultaneous Liquid and Vapor Withdrawal The dual cylinder valve was designed especially for industrial uses. It increases the cylinder’s flexibility by permitting DOT cylinders up to 100 lbs. propane capacity to be used interchangeably or simultaneously for either liquid or vapor withdrawal. MFR# 8556

MFR# 8556

Service Connection

container connection

VAPOR

3/4” M. NPT

F. POL CGA 510

Pressure relief valve setting

For use in cylinders with propane capacity up to

375 PSIG

100 lbs.

LIQUID

FIXED LIQUID LEVEL VENT VALVE STYLE

LIQUID WITHDRAWAL TUBE LENGTH

CGA 555

None

44”

approximate filling rate liquid flow, GPM Pressure drop across valves 10 psig

25 psig

50 psig

100 psig

Liquid closing flow* (LP-Gas)

Webb#

6.6

10.0

14.5

21.0

2.3 GPM

189194

* To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use. NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

Service Valves for ASME and DOT Containers or Fuel Line Applications

9101C

MFR#

9101R11.7

BONNET STYLE

Designed especially for vapor withdrawal service on ASME and DOT containers or in fuel line applications. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity.

container connection

service connection

9101C1 9101DT11.1

Standard

9101DT11.7 9101R11.7

MultiBonnet

3/4” M. NPT

F. POL CGA 510

FIXED LIQUID LEVEL VENT VALVE

APPROXIMATE FILLING RATE liquid flow, gpm pressure drop across valve 10 PSIG

25 PSIG

50 PSIG

100 PSIG

Webb#

No

8.8

12.4

15.8

21.7

186993

Yes

8.6

12.7

16.3

22.3

Yes

7.6

11.7

15.2

20.6

273828 273829 162724

NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

31

valves & accessories

approximate filling rate liquid flow, GPM

2


SECTION

2

Cylinder & Service Valves

Service Valve for DOT Fork Lift Containers Designed especially for vapor or liquid withdrawal service on DOT fork lift containers. Valves with 1.5 GPM closing flow are for use in small and medium size lift truck applications, while those with 2.6 GPM closing flow are for large lift trucks and gantry crane type vehicles. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that cylinders capacity. The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture. When installed for liquid withdrawal, the 9101P6 Series has provisions for attachment of a liquid withdrawal tube. The 9101P5 Series must be installed in containers that have provisions for a separate liquid withdrawal. 9101P5

CLOSING FLOW (LP-GAS)

MFR#

CONTAINER CONNECTION

Service CONNECTION

9101P5 9101P5H 9101P6

3/4” M. NPT

3/8” M. NPT 1/4” NPT

9101P5H 9101P6 9101P6H

100 PSIG INLET (SCFH)

LIQUID (GPM)

430

900

1.5

550

1050

2.6

430

900

1.5

550

1050

2.6

approximate filling rate liquid flow, gpm

accessories

pressure drop across valves

ACME CHECK CONNECTORS

9101P6 9101P5

25 PSIG INLET (SCFH)

None

9101P6H

MFR#

VAPOR

LIQUID WITHDRAWAL CONNECTION

10 PSIG

25 PSIG

50 PSIG

100 PSIG

5.0

7.6

10.7

14.9

Male

7.2

10.3

CAP

7141F

7141M-40 or 7141FP

Webb# 162720

7141M 4.5

FEMALE

14.8

162721 186995 190685

To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use.

Service Valves for ASME Motor Fuel Containers

9101H5

Designed specifically for vapor or liquid withdrawal service on ASME motor fuel containers. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity. The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture. When installed for liquid withdrawal, the 9101H6 has provisions for attachment of a liquid withdrawal tube. All other valves must be installed in containers that have provisions for a separate liquid withdrawal. CLOSING FLOW (LP GAS)

9101H6 MFR#

VAPOR LIQUID container Service WITHDRAWAL 25 PSIG 100 PSIG LIQUID connection Connection CONNECTION INLET (SCFH) INLET (SCFH) GPM Webb#

9101H5* 9101H6* 9101Y5H*

9101Y5H

3/4” M. NPT

* SAE Flare 60° Angle * SAE Flare

None

765**

1300**

3.6**

162499

1/4” NPT

550****

1050****

2.6****

189199

None

550**

1050**

3.6**

162500

*Heavy-duty models. **Based on 3/8” O.D. pigtail, 20” long or less, connected to valve outlet. For greater lengths the pigtail must have a larger O.D. ***Same as (**) . In addition, 1/4” O.D. pigtails or POL connections for 1/4” O.D. should not be used with this valve. ****Based on 3/8” O.D. pigtail: 20” long or less, connected to valve outlet. Also based on 1/4” pipe size dip tube, 42” long or less, attached to special inlet connection. For longer pigtail lengths, the diameter of the pigtail must be increased. To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use.

32

Gas Equipment Catalog

victormfg.com


SECTION

2

Multivalve Assemblies ASME Multivalves® for Vapor Withdrawal These Multivalves® are designed for use in single opening ASME containers equipped with a 21/2” M. NPT riser. They can be used with underground ASME containers up to 639 sq. ft. surface area, and above ground ASME containers up to 192 sq. ft. surface area. A separate opening is required for liquid withdrawal. The MultiBonnet® is standard on this valve. The MultiBonnet® allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM

2

Pressure Drop across valves 10 psig

25 psig

50 psig

100 psig

42

72

98

125

G8475RV

G8475RW

G8475RW

VAPOR EQUALIZING CONNECTION MFR# G8475RV G8475RW

CONTAINER CONNECTION

SERVICE CONNECTION

FILLING CONNECTION

CONNECTION SIZE

UL LISTED CLOSING FLOW

FLOAT GAUGE FLANGE OPENING

21/2” F. NPT

F. POL CGA 510

13/4” M. Acme

11/4” M. Acme

4200 CFH at 100 PSIG

Fits “Junior” Size

FIXED LIQUID LEVEL VENT VALVE STYLE

MFR# G8475RV

Knurled

Pressure relief valve DIP TUBE LENGTH

MFR#

UL

ASME

FOR USE IN *CYLINDERS WITH SURFACE AREA UP TO

M3131G

2020 SCFM/air

1939 SCFM/air

83 sq. ft. Above Ground 276 sq. ft. Underground

187104

MV3132G

3995 SCFM/air

n/a

192 sq. ft. Above Ground 639 sq. ft. Underground

190680

Flow Capacity SETTING

30”*

250 PSIG

G8475RW

Webb#

* Dip tube not installed, may be cut by customer to desired length.

For specific repair parts, see the end of this section.

ASME Multivalves® for Vapor Withdrawal These Multivalves® provide vapor withdrawal and filling of ASME containers. A separate pressure relief valve is required in addition to this valve. The MultiBonnet® is standard on this valve. MultiBonnet® allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves

8593AR16.0

MFR# 8593AR16.0

10 psig

25 psig

50 psig

100 psig

Webb#

42

72

98

125

162498

VAPOR EQUALIZING CONNECTION

MFR# 8593AR16.0

CONTAINER SERVICE CONNECTION CONNECTION 11/2” M. NPT

F. POL CGA 510

FILLING CONNECTION CONNECTION SIZE 13/4” M. Acme

11/4” M. Acme

UL LISTED CLOSING FLOW

Fixed liquid level vent valve style

dip tube length

for use in Containers with surface area up to:

Knurled

16”*

**

4200 CFH at 100 PSIG

* Dip tube not installed, may be cut by customer to desired length. ** Since these Multivalves® have not integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

33

valves & accessories

MFR#


SECTION

2

Multivalve Assemblies DOT Multivalves® for Liquid Withdrawal

These Multivalves® permit liquid withdrawal from DOT cylinders with up to 100 lbs. propane capacity. They eliminate unnecessary cylinder handling when servicing high volume loads and allow on-site filling into the vapor space without interrupting gas service. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves MFR# 8555dl11.6

10 psig

25 psig

50 psig

100 psig

8

23

34

42

8555DL11.6 MFR#

CONTAINER SERVICE CONNECTION CONNECTION

8555dl11.6

MFR#

3/4” M.NPT

CGA 555*

FILLING CONNECTION

Fixed liquid level vent valve style

dip tube length with deflector

13/4” M. Acme

Knurled

11.6”

liquid withdrawal tube length

pressure relief valve setting

for use in cylinders with propane capacity up to

liquid closing flow (Lp. gas)***

Webb#

44”

375 PSIG

100 lbs.**

1.7 GPM

162734

8555dl11.6

*Use adapter 12982 to connect to pipe threads. **Per CGA Pamphlet S-1.1. ***To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use. ®

DOT Multivalves for Vapor Withdrawal

These Multivalves® permit vapor withdrawal from DOT cylinders with up to 200 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves MFR#

25 psig

50 psig

100 psig

Webb#

6555r11.6

359339

6555r12.0

8555d10.6

162732

8555R10.6

162740

8555d11.6

8555D11.6

10 psig

8

23

34

42

162733

8555R11.6

162741

8555dt10.6

273825

8555dt11.6

273826

8555dt8.2

273827

T = Threadsealent

bonnet style

application

for use in containers with size up to

dip tube length with deflector

6555r11.6

MultiBonnet

ASME Containers

25 ft. Surface Area or 60 Gallons Water Capacity

11.6”

8555D10.6

Standard

8555R10.6

MultiBonnet

8555D11.6

Standard

8555R11.6

MultiBonnet

MFR#

10.6”

DOT Containers

200 lbs. Propane

8555DT10.6 8555DT11.6

11.6”

3/4” M. NPT

10.6” Standard

11.6”

8555DT8.2

34

container connection

8.2”

Gas Equipment Catalog

victormfg.com


SECTION

2

Multivalve Assemblies DOT Multivalves® for Liquid Withdrawal (continued)

PRessure relief valve

MFR#

fixed flow liquid capacity* level service filling vent ul connection connection style setting listing asme 793 SCFM/ air

700 SCFM/ air

359339

8555D10.6

162732

8555R10.6

162740

8555D11.6

F. POL CGA 510

13/4” M. Acme

Knurled

162733 375 PSIG

8555R11.6

n/a

n/a

162741

8555DT10.6

273825

8555DT11.6

273826

8555DT8.2

273827

T = Threadsealent * Per CGA Pamphlet S-1.1.

DOT and ASME Multivalves® for Vapor Withdrawal These Multivalves® permit vapor withdrawal from ASME containers up to 50 sq. ft. surface area and DOT containers up to 420 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves

6543A11.7

MFR# 6532A12.0 6532R12.0 6542A12.0 6542R12.0 6533A11.7 6533R11.7

10 psig

25 psig

50 psig

11

16

23

23

32

46

11

16

23

100 psig

— 162735 373827 162737 28

6543A11.1 6543R11.1 6543A11.7

Webb#

162729 162736 162730

23

32

162738

46

162731

6543R11.7

162739

6543AT10.3

273821

6543AT11.7

275093

T = Threadsealent

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

35

2 valves & accessories

250 PSIG

6555r11.6

webb#


SECTION

2

Multivalve Assemblies DOT and ASME Multivalves® for Vapor Withdrawal (continued) MFR#

bonnet style

6532A12.0

Standard

6532R12.0

MultiBonnet

6542A12.0

Standard

6542R12.0

MultiBonnet

6533A11.7

Standard

6533R11.7

MultiBonnet

6543A11.1

Standard

6543R11.1

MultiBonnet

6543A11.7

Standard

6543R11.7

MultiBonnet

MFR#

application

container connection

Service connection

fiLling connection

Fixed Liquid level Vent valve style

F.POL CGA 510

13/4” M. Acme

Knurled

3/4” M. NPT

ASME* 1” M. NPT 3/4” M. NPT

DOT 1” M. NPT

dip tube length with deflector

pressure relief valve setting

for use in cylinders with propane capacity**

For use in containers with surface area up to***

6532A12.0

43 sq. ft.

6532R12.0

12.0”

6542A12.0

250 PSIG

162735

373827

53 sq. ft.

6542R12.0 6533A11.7

162737 162729

11.7”

6533R11.7 6543A11.1

162736

11.1”

6543R11.1 6543A11.7

375 PSIG

420 lbs. Propane

162730

162738 162731

11.7”

6543R11.7

WEBB#

162739

* UL rated flow capacities are 6532A 12.0-1180 SCFM/air, 6542A 12.0-1530 SCFM/air. ** Per CGA Pamphlet S-1.1. *** From NFPA 58, Appendix D.

ASME Multivalves® for Vapor Withdrawal These compact Multivalves® are especially suited for vapor withdrawal of ASME containers where compact groupings of components are necessary. Separate filler valves and pressure relief valves are required. MultiBonnet® allows quick and easy repair of bonnet. VAPOR EQUALIZING CONNECTION

7556R12.0

MFR# 7556R12.0

CONTAINER CONNECTION

SERVICE CONNECTION

CONNECTION SIZE

UL LISTED CLOSING FLOW

3/4” M. NPT

F. POL CGA 510

11/4” M. Acme

4200 CFH at 100 PSIG

7556ZT MFR# 7556R12.0

Special/Thread Connection O-Ring fixed liquid level vent valve style

dip tube length

for use in containers with surface up to

webb#

Knurled

12”

*

162742

7556ZT

* Since these Multivalves® have no integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.

36

Gas Equipment Catalog

victormfg.com


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds Fully Internal “Pop-Action” Pressure Relief Valves for Transport and Delivery Trucks Designed specifically for use as a primary relief valve in ASME transports and delivery trucks with 2” and 3” NPT couplings. A8434G

Start to discharge setting Container PSIG Connection

Overall height

Height Above Coupling

(approx.)

(approx.)

Ul

ASME

(at 120% of Set Pressure)

Suitable for Tanks with Protective Surface cap (included) webb# Area up to*

A8434G

250

2” M. NPT

91/16”

1/2”

3700

3456

175 sq. ft.

A8434-11B

187081

A8436G

250

3” M. NPT

17”

3/4”

10210

9598

602 sq. ft.

A8436-11B

162575

* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.

Fully Internal “Pop-Action” Pressure Relief Valves for Motor Fuel Containers 8544T

8543 Series relief valves are designed for use as a primary relief valve in larger ASME motor fuel containers such as on buses, trucks and construction equipment. 8544 Series relief valves are designed for use as a primary relief valve in smaller ASME and DOT motor fuel containers such as on tractors, lift trucks, cars and taxicabs.

MFR#

Container type

Start to discharge setting PSIG

8544G 8543G

ASME

1”

DOT/ASME

375

1”

8544GT

ASME

250

1”

8544KT

DOT/ASME

375

1”

Flow capacity SCFM/AIR***

MFR#

hex wrenching Section

8544G

15/16”

1020

8543G

111/16”

8544T

Height Above Coupling

57/16”

7/8”

(approx.)

(approx.)

11/4”

312

8544K

Ul

Overall height

1”

250

8544T

Container Connection m. npt

ASME

accessories Protective Cap (included)

pipeaway adapter

webb#

936

7544-41

7544-11A*

162757

1465

1400

7543-40C

7543-10**

189192

15/16”

1282

1158

7544-41

7544-11A

189193

8544K

15/16”

1545***

7544-41

7544-11A

162758

8544GT

15/16”

1020

936

7544-41

7544-11A

273823

8544KT

15/16”

1545***

7544-41

7544-11A

273824

(at 120% of Set Pressure)

T = Threadsealent *1” M.NPT outlet connection. **11/4” M.NPT outlet connection. ***Rating also applies to DOT requirements. ****Flow rates shown are for bare relief valves. Adapters and pipeaway will reduce flow as discussed in forewording information.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

37

valves & accessories

MFR#

2


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds

Fully Internal “Pop-Action” Pressure Relief Valve for DOT Fork Lift Cylinders Designed specifically for use as a primary relief valve on forklift cylinders, the 8545AK reduces the possibility of improper functioning of the relief mechanism due to foreign material build up. All guides, springs, stem and adjusting components are located inside the cylinder — removed from the direct exposure of foreign materials and debris from the atmosphere.

8545AK With Protective Cap

MFR# 8545AK

Start to Container discharge Type setting PSIG Dot

Container connection m. npt 3/4”

375

Flow Capacity scfm/Air**

Accessories (ORder Separately) Deflectors***

(ECII® Rated at 480 PSIG)

Protective cap

45º Elbow

90º Elbow

WEBB#

400*

7545-40

7545-14A

7545-12

162759

* Classified by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders. Meets requirements for use on DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas. ** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information. *** Order protective cap #8545-41 or 7545-40.

Semi-Internal “Pop-Action” Pressure Relief Valve for ASME Containers Designed specifically for use as a primary relief valve on ASME containers such as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists containers systems on which these types of valves are mounted outside the hood without additional protection, if mounted near the hood and fitted with a protective cap.

MFR#

Start to discharge setting PSIG

7583G 8684G

7583G

250

8685G

Container Connection M. NPT

Overall height

3/4”

1” 11/4”

Flow Capacity SCFW/AIR Ul MFR#

38

ASME

(at 120% of Set Pressure)

Height Above Coupling (approx.)

Wrench Hex Section

83/16”

17/16”

13/4”

93/8”

19/16”

17/8”

111/16”

111/16”

23/8”

(approx.)

Suitable for Tanks with Surface Area up to

Protective cap (included)

webb#

7583G

1980

1806

80 sq. ft.

7583-40X

162747

8684G

2620

2565

113 sq. ft.

8684-40

162749

8685G

4385

4035

212 sq. ft.

7585-40X

162750

Gas Equipment Catalog

victormfg.com


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds Semi-Internal “Pop-Action” Pressure Relief Valve for Large Storage Containers Designed specifically for use as a primary relief valve on large stationary storage containers, these low profile relief valves are generally mounted in half couplings. However, they are designed so that the inlet ports clear the bottom of a full 2” coupling. This assures that the relief valve should always be capable of maximum flow under emergency conditions.

7534-40

7534-20

Flow capacity SCFM/AIR* UL

MFR#

Start to discharge setting PSIG

Container Connection

7534G

250

2” M. NPT

ASME

(at 120% of Set Pressure)

11675

accessories

Suitable for tanks with surface area up to**

protective cap

pipeaway adapter

webb#

708 sq. ft.

7534-40

7534-20***

162574

10422

* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the forewording information. ** Per NFPA Pamphlet #58, Appendex D. Area shown is for UL or ASME—whichever is larger. *** 3” F.NPT outlet connection.

External “Pop-Action” Supplementary Pressure Relief Valves for Small Containers and DOT Cylinders

3127 Series

MFR#

Designed for use as a supplementary relief valve on small ASME above ground and underground containers. They may also be used as a primary or secondary relief device on DOT cylinders, or as hydrostatic relief valves. All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage.

3127G

Container Type

Start to discharge setting PSIG

ASME

250

3127G 3129G 3127K

DOT

3129K

Container Connection M. NPT

Overall Height (Approx.)

Wrench HEx Section

1/4”

131/32”

7/8”

1/2”

219/32”

11/8”

1/4”

131/32”

7/8”

1/2”

219/32”

11/8”

375

Flow capacity SCFM/AIR* UL

MFR#

(at 120% of Set Pressure)

3127G

295

3129G

465

3127K 3129K

ASME

­—

accessories Suitable for tanks with surface area up to*

pipeaway adapter protective cap

450

100 lbs./Propane

780

200 lbs./Propane

Outlet Size

MFR#

7545-40

162420 1/2” F. NPT

3129-10 — 3129-10

webb# 162429 162424

1/2” F. NPT

* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

39

valves & accessories

7534G

2


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds

3135-10

External “Pop-Action” Pressure Relief Valve for ASME Containers and Bulk Plant Installations Designed for use as a primary relief valve on ASME above ground and underground containers, bulk plant installations and skid tanks. The 3131 Series may also be used as a primary or secondary relief valve on DOT cylinders, or as a hydrostatic relief valve. All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage. Flow Capacity SCFW/AIR (a)

3135 AA3135

MFR# AA3126L030

Start to discharge setting PSIG 30

AA3126L250 3131G W3132G MV3132G

Overall height (approx.)

Wrench Hex Section

1/2”

2”

3/4”

AA3130UA250 3132G

Container Connection M. NPT

11/4”

AA3135UA250

Suitable for Tanks with Surface area up to (e) —

AA3126L250

23 sq. ft. (f)

AA3130UA250

521/32”

277 (c)

2060

1939

2045

1838

4130

211/16”

5770

6430

5080 (d)

6080

101/2”

41/8”

10390

9153

37/16”

103/4”

2125

1912

515/16”

21/2” 3/4”

accessories pipeaway adapter protective cap

MFR#

outlet size

7545-40

AA3126-10

1/2” M. NPT

85 sq. ft.

3131-40 (g)

249 sq. ft. (f)

AA3130-40P

weep hole deflector

webb# 187092

187093 162436

AA3131-10

1” F. NPT

187095

3132-10

11/4” F. NPT

162444

3132G

200 sq. ft.

MV3132G

190 sq. ft.

3135G

300 sq. ft.

3135-54 (g)

3135-10

1010 sq. ft. (f)

AA3135-40PR

AA3135-10

3133G

320 sq. ft.

3133-40 (g)

A3149G

613 sq. ft.

3149-40

261 sq. ft. (f)

AA3130-40P

(b) (c) (d) (f ) (g) (h) (j)

31/8”

11/2”

154 sq. ft.

AA3130UA265

(b)

3995

W3132G

AA3135UA250

40

265

AA3126L030 3131G

2”

613/32”

A3149G

ASME

(at 120% of Set Pressure)

3340 61/32”

250

3133G

MFR#

13/4”

1”

3135G

AA3130UA265

37/16”

UL

3132-54 (g)

162442

— 3133-11 2” F. NPT

162447 190683 162446

(h) AA3131-10

188588

1” F. NPT

Included (j)

162572

189239

Not UL or ASME rated. .059 sq. in. effective area. Not UL or ASME rated. ECII® rated at 120% of set pressure. Rated at 110% of set pressure. Per ANSI K61.1-1972. Appendix A Cap supplied with chain. Outlet 31/2-8N (F) thread, will accept 3” M. NPT pipe thread. Weep hole deflector is Part No. A3134-11B.

Gas Equipment Catalog

victormfg.com


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds External Hydrostatic Relief Valves Designed especially for protection of piping and shut-off valves where there is a possibility of trapping liquid LP-Gas or anhydrous ammonia. They may be installed in pipelines and hoses located between shut-off valves or in the side of boss in RegO® shut-off valves.

2 SS8022G Accessories

MFR#

Start to discharge setting PSIG

Valve Body Material

SS8001G

1/4”

SS8002G SS8021G SS8022G

Container Connection M. NPT

250

Stainless Steel

1/2” 1/4” 1/2”

Height

(Approx.)

— 1”

Wrench Hex Section

pipeaway protective adapter or cap threads (included)

11/16”

— 11/16”

— —

webb# 283973 189248

1/4” NPSM Thrds

162494

3/8” NPT Thrds

189249

162420

3127G

1/4”

131/32”

3129G

1/2”

219/32”

1”

3129-10

162429

1/4”

131/32”

7/8”

162422

1/2”

219/32”

11/8”

3129-10

186844

1/4”

131/32”

7/8”

186843

1/2”

219/32”

11/8”

3129-10

3127J

1/4”

131/32”

7/8”

162423

3129J

1/2”

219/32”

11/8”

3129-10

162430

1/4”

11/16”

187114

1/4” NPSM Thrds

193305

3/8” NPT Thrds

187116

162424

3129-10

3127H 3129H 3127P 3129P

SS8001J

275 Brass 300

350

SS8021J SS8022J 3127K 3129K

Stainless Steel

375 Brass

3125L 3127L 3129L SS8001L

400 Stainless Steel

SS8021L SS8022L 3127U

Brass

3129U SS8001U SS8002U SS8021U SS8022U

450

1/4” 1/2”

11/16”

7/8”

1/4”

131/32”

1/2”

219/32”

11/8”

19/16”

5/8”

3125-40P

131/32”

7/8”

7545-40

1/2”

219/32”

11/8”

3129-40P

1/4”

7/8”

11/16”

1/4”

1/4” 1/2”

13/8”

1/4”

131/32”

1/2”

219/32”

1/4”

Stainless Steel

1”

7545-40

1/2” 1/4” 1/2”

— 1”

11/16”

7545-40

— 1”

7545-40

11/16”

— 11/16”

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

162426

3129-10

1/4” NPSM Thrds

162495

3/8” NPT Thrds

162428

3129-10

162432

— —

162751

162490 —

1/4” NPSM Thrds

162496

3/8” NPT Thrds

189250

41

valves & accessories

3127G


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds

DuoPort® Pressure Relief Valve Manifolds for Small Storage Containers Designed especially for use as a primary relief device on smaller stationary storage containers, with 2” NPT threaded couplings. These manifolds allow servicing or replacement of either of the two relief valves without evacuating the container or loss of service. The operating lever selectively closes off the entrance port to the relief valve being removed while the remaining valve provides protection for the container and its contents. The rating of each manifold is based on actual flow through the manifold and a single pressure relief valve, taking friction loss into account, it is not merely the rating of the relief valve alone. AA8542UA250

MFR#

start discharge setting psig

application lp-gas

8542G

250

AA8542UA250

250

nh3

Container connection M. NPT

Yes

No

2”

No

Yes

2”

flow capacity scfm/air** (at 120% of set pressure)

Relief valve included MFR#

quantity

MFR#

inlet connection M. NPT

Accessory

8542G

2

3135MG

11/4”

3135-10*

5250 (1)

NA

189191

AA8542UA250

189245

pipeaway adaptors

UL rating

asme rating

webb#

* 2” F. NPT outlet connection. ** Flow rating based on number of relief valves indicated in parenthesis ( ). Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow rates as discussed in forewording information.

Multiport® Pressure Relief Valve Assemblies for Large Storage Containers Designed especially for use as a primary relief device on large stationary pressurized storage containers with flanged openings. These manifolds incorporate an additional relief valve, not included in the flow rating, allowing for servicing or replacement of any one of the relief valves without evacuating the container. The handwheel on the manifold selectively closes off the entrance port to the relief valve being removed while the remaining relief valves provide protection for the container and its contents. All manifold flow ratings are based on flow through the relief valves after one has been removed for service or replacement. start discharge setting psig

MFR#

application lp-gas

nh3

A8564G

3” - 300#

A8574G

A8564G

250

A8564AG

Yes

Yes

A8574AG

quantity

A8564G A8574G A8564AG A8574AG

42

MFR#

3” - 300#

flow capacity scfm/air

inlet connection M. NPT

(at 120% of set pressure)

Accessory pipeaway adaptors

A3149MG 4

4” - 300# 4” - 300#

Relief valve included MFR#

Container Flange connection

21/2”

UL rating

asme rating

27,750 (3)

N/A

Not Applicable

27,400

Outlet 31/2-*N (F) thread, will accept 3” M. NPT pipe thread.

A3149G

Gas Equipment Catalog

webb# 162576 162577 251121 251122

victormfg.com


SECTION

2

Pressure Relief Valves & Relief Valve Manifolds Multiport® Pressure Relief Valve Assemblies for Large Storage Containers (continued) MFR#

consists of

for use with

for connection to

7560-55

1-Bolt Stud and Nut

All RegO MultiportsTM

Modified 3” - 300# and 4” - ASA 300# Welding Neck Flange

webb# 186924

8

Manhold Cover Plate

189178

Flange Dimensions Manifold Sizes

flange size

flange drilling

port diameter

flange gasket

A8560

Modified 3” 300# (4” Port Dia.)

(8) 7/8” Bolt Holes on a 65/8” Bolt Circle Diameter Flat Faced.

4”

3” 7564-48

A8570 AA8570

4” ASA 300#

(8) 7/8” Bolt Holes on a 77/8” Bolt Circle Diameter 1/16” Raised Face.

4”

4” 7565-48

Flanged Internal Valves Gasket Mounting Information MFR# Description MFR#

Description

Webb#

7560-55

1 Nut and Stud

186924

7560-56

2 Nuts and Stud

189178

7560-58

3.50 Length

7560-60

1.13 Hex .64 Thk

Webb#

7565-48

7.00 O.D. 5.00 I.D. 0.13 Thk

273810

7884-30

7.00 O.D. 5.82 I.D. 0.18 Thk

186948

A7883-29

5.75 O.D. 4.75 I.D. 0.18 Thk

187055

A7883-30

8.75 O.D. 4.00 I.D. 0.13 Thk

187057

Victor/F.w. Webb has a “Trade-in” program for multiport pressure relief valves.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

43

2 valves & accessories

7560-56

Number required


SECTION

2

Globe & Angle Valves

“V”–Ring Seal Globe and Angle Valves for Bulk Storage Containers, Transports, Bobtails and Plant Piping Specifically designed to assure positive shut-off and long, maintenance-free service life in liquid or vapor service on bulk storage containers, transports, bobtails, cylinder filling plants and plant piping. The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries. TA7034 A7505AP MFR#

Webb#

TA7034P

TA7034LP

189253

A7505AP

162539

A7506AP

162540

TA7505AP

187120

TA7506AP

A7507AP

162541

A7508AP

162542

TA7507AP

192877

A7509BP

162543

A7510BP

162544

GLOBE

ANGLE

GLOBE

ANGLE

inlet & Outlet connection

TA7509BP

193216

TA7034P

TA7034LP

1/2” F. NPT

TA7510BP

A7505AP A7506AP TA7505AP TA7506AP

3/4” F. NPT

A7511AP

162545

A7512AP

162546

TA7511AP

273830

TA7512AP

A7511FP

A7513AP A7514AP TA7513AP

A7513FP

A7513AP

A7513AP A7517FP

A7517AP flow at 1 psig pressure drop (cv) (gpm/ propane)***

MFR#

BUNA N SEAT DISCS

A7518FP

TEFLON SEAT DISCS* port diameter 3/4”

Globe

angle

10.00

14.8

12.0

17.7

1” F. NPT

1”

17.8

22.0

A7509BP A7510BP TA7509BP TA7510BP

11/4” F. NPT

11/4”

36.5

54.0

A7511AP A7512AP

11/2” F. NPT

43.0

55.5

46.0

A7507AP A7508AP TA7507AP

A7511FP

— A7514FP

­—

TA7511AP

TA7512AP

TA7513FP

TA7614FP

11/2” Flange** 2” F. NPT 2” Flange**

11/2” 2”

75.0

88.5

78.0

133.0

197.0

303.0

accessories hydrostatic relief valve

vent valve

SS8001U #162490

TSS3169 #162450

162547

A7517AP A7518AP TA7517AP TA7518AP

A7514AP

162548

A7517FP

TA7513AP

190681

A7513FP

188570

* Teflon seat discs on valves built to order. ** 300# ANSI R.F. Flange *** To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in chart by square root of pressure drop.

A7514FP

162549

Flange Dimensions

TA7513FP

187124

A7517AP

162550

A7518AP

162551

TA7517AP

187126

TA7518AP

A7517FP

187041

A7518FP

162552

TA7517FP

44

189255

A7518FP

TA7517FP

3” F. NPT 3” Flange**

3”

Valve number

size

flange drilling

D

E

F

H

7511FP

11/2”

7/8” Bolt Holes on a 41/2” Bolt Circle Diameter

61/8”

13/16”

27/8”

3/4”

2”

3/4” Bolt Holes on a 5” Bolt Circle Diameter

61/2”

7/8”

35/8”

13/16”

7517FP

3”

7/8” Bolt Holes on a 65/8” Bolt Circle Diameter

81/4”

11/8”

5”

11/16”

7518FP

7513FP 7514FP

Reducing screwed flanges are available for reducing 11/2” flange or 1” or 11/2” pipe thread and 3” flanged to 21/2” pipe thread. Order from your local supplier.

Gas Equipment Catalog

victormfg.com


SECTION

2

Globe & Angle Valves Quick-Acting Minimum Loss Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations

A7797A

Locking Handle

Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)

webb#

13/4”

Yes

16.0

187049

13/4”

Yes

16.0

162563

MFR#

Inlet Connection F. NPT

outlet connection f. Acme

A7793A

3/4”

A7797A

1”

Quick-Acting Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations

A7707L

Designed especially for safe operator handling of LP-Gas in bobtail delivery truck, dispensing systems and anhydrous ammonia nurse tank service. These valves provide instant, full-on flow at the flip of the handle and provide instant positive shut-off with a handle lock for added protection. accessories

MFR#

Body Design

A7707L

Globe

A7708L

Angle

inlet & outlet connection

locking handle

1”

Yes

Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane) 18.0 22.0

filling connectors extended

compact

Steel

brass

steel

webb#

A7575L4 #162711

3175A #162688

A3175A #162689

187048 162562

Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant Piping

A7704P

Designed to assure positive shut-off and long maintenance-free service life in liquid or vapor service. Ideally suited for use on cylinder charging manifolds, truck filling hoses, bulk storage containers and plant piping. The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries. inlet & outlet connection F. NPT

Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)

MFR#

body design

7704P

Globe

7.3

7704LP

Angle

12.3

A7704P

Globe

A7704LP

Angle

1/2”

Accessories hydrostatic relief valve

7.3 12.3

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Vent valve

webb# 162557

SS8001J or SS8001L

TSS3169

190689 162558 162559

45

2 valves & accessories

Designed to vastly reduce the amount of product vented when disconnecting bobtail trucks, dispensing systems and anhydrous ammonia nurse tanks. These valves provide instant, full-on-flow at the flip of a handle. Shut-off is instant and the handle locks for added protection. This “top of the line” hose-end valve is a fully contained unit that does not require additional filling adapters or connectors.


SECTION

2

Globe & Angle Valves

Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant Piping (continued)

A7706P

inlet & outlet connection F.NPT

Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)

MFR#

body design

7705P

Globe

11.5

7706P

Angle

17.7

A7705P

Globe

A7706P

Angle

3/4”

Accessories hydrostatic relief valve

Vent valve

webb# 163076

SS8001J or SS8001L

11.5

TSS3169

17.7

163077 162560 162561

Flange Seal Liquid Transfer Angle Valves for Bulk Storage Containers

7550P

MFR#

inlet & outlet connection M. NPT

Designed especially for liquid transfer of LP-Gas from consumer bulk storage containers when used with a Chek-Lok® or equipped with an integral excess flow valve. May also be used for vapor LP-Gas service. In NH3 applicator tanks they may be used as a vapor bleeder valve or as a liquid withdrawal valve when installed in a coupling with a dip pipe. These liquid transfer valves are equipped with an integral excess flow valve for liquid transfer directly from the tank fitting, or without an integral excess flow for LP Gas transfer through a Check-Lok®. When equipped with an integral excess flow valve (7550PX), the valve should be mounted in a forged steel 3000 lb. half coupling. When mounted in a 11/4” X 3/4” NPT reducing coupling, the 3/4” female thread in this coupling must be full length — equivalent to a forged steel 3000 lb. half coupling. The excess flow valve will not function properly if these specifications are not met.

outlet connection F. NPT

7550P

No

A7550P 7550PX A7550PX 7551P A7551P

46

Flow at 1 PSIG (CV) integral Pressure excess Drop flow (GPM/Propane) 13.3

accessories Excess Flow HydroApproximate static closing flow Relief (GPM/Propane) valve —

3/4” 3/4”

Yes 1/2”

No

Gas Equipment Catalog

— 8.9

16.0 —

vent valve

webb#

3127U

3165

162760

SS8001J

TSS3169

162474

3127U

3165

162476

SS8001J

TSS3169

162475

3127U

3165

266448

SS8001J

TSS3169

273806

victormfg.com


SECTION

2

Globe & Angle Valves Quick-Acting Valves for Cylinder Charging Hoses Designed primarily for use on cylinder charging hoses to provide fast, convenient shut-off and fast opening. These valves must be installed so that flow through the valve is in the opposite direction to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve, even more important, helps prevent the valve from being forced open by high pump pressure.

MFR#

outlet connection f. NPT

BODY MATERIAL

A7553A

1/4”

1/4”

Ductile Iron

7901TA

3/8”

3/8”

7901TB 7901TC

1/4”

1/2”

Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)

webb# 189220

1.95

Brass

1/2”

162487 162488 162489

Quick-Acting Valves for Crop Driers and Charging Manifold Hoses

7554S

7554S Series valves provide instant shut-off and fast opening control on LP-Gas crop driers. They are ideal for charging manifold hoses, stationary fuel transfer hoses and other applications requiring quick, positive shut-off. They are not for use with delivery truck hoses because the handle could snag on the ground and open the valve as the hose is needed back to the truck 7554L Series valves feature a locking handle device to help prevent accidental opening of the valve. It is ideal for all the same applications as the 7554S Series and may be used on delivery trucks as it incorporates the locking handle design. Both valve series must be installed so that flow through the valve is opposite to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve and prevents the valve from being opened by high pump pressures.

MFR# 7554SAV 7554LAV 7554SV 7554LV

Inlet & Outlet Connection F. NPT 1/2”

3/4”

Locking Handle

Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)

No Yes No Yes

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

7.3 11.5

webb# 186921 186920 162555 162553

47

valves & accessories

7901TA

Inlet Connection F. NPT

2


SECTION

2

Globe & Angle Valves

Multipurpose Valves for Liquid Withdrawal of LP-Gas and NH3 Containers Designed especially for use as a high capacity liquid withdrawal valve on LP-Gas and anhydrous ammonia containers. The A8017DH is equipped with a soft seated automatic differential back pressure check valve in the seat disc assembly. This allows any pressure build up in the liquid transfer line in excess of 10-15 psig above the container pressure to flow back into the container. The transfer hose is protected against excessive liquid or vapor pressure entrapment, which adds materially to the useful life of flexible hose. In addition to increasing hose service life, the equalizing valve adds substantially to the operating safety of liquid transfer systems. Accessories

A8017DP MFR#

Excess Flow Inlet outlet Approximate Connection connection closing flow M. NPT f. NPT (GPM/Propane)

A8017DH A8017DP

11/4”

1”

A8017DLP

Hydrostatic relief valve

vent valve

49

Not Required

55

SS8001J

TSS3169

webb# 187075 162493

190679

Multipurpose Valve for Filling and Liquid Transfer of NH3 Containers Designed primarily for use as a combination filler and liquid withdrawal valve on threeopening applicator tanks or on nurse tanks. This valve incorporates an integral excess flow valve. When product is required, the valve must be completely open and backseated to allow the excess flow valve to function properly.

A8018DP

MFR# A8018DP

48

Inlet outlet Filling Connection connection Connection M. NPT f. NPT M. acme 11/4”

1”

13/4”

Gas Equipment Catalog

Filling capacity at 20 psig pressure drop gpm/ nh3

Excess Flow Approximate closing flow (GPM/nh3)

Hydrostatic relief valve

vent valve

webb#

74

50

SS8001J

TSS3169

187076

Accessories

victormfg.com


SECTION

2

Ball Valves Gas Ball Valves

For use on LP-Gas, flammable liquids, natural and mfg. gas, air, N2, inert gases, including helium and CO2. • 1/4” – 2” • Operable from -40°F to 300°F • UL listed

Model T/S-100 Webb# 184932 184933 151448 151449 163961 151450 151451 163962 — 151453 151454 151455 151456 151457 151458 151459 —

The new Jomar System-2 FIP to Flare, Flare to Flare and MIP to Flare valves are new products with vision. Equipped with all the features of the Blue-Cap®. • Raised wrench flats for installation ease. • It can be used in temperatures from -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The T-handle can be reversed into a locked position, by turning the handle to the off position, removing the tamper proof alien screw and reversing the handle 180° into the slot. • Each valve is shipped with plastic thread protectors to prevent leak causing nicks. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • AGA and CGA listed 0.5, 2 lb., 5 lb., System. Mfr# Desc. Model T-204 – FIP X FL JOM101-502 1/2” X 3/8” FIP X FL JOM101-503 1/2” FIP X FL Model T-204 – FL X FL JOM101-601 1/2” X 3/8” FL X FL JOM101-602 3/8” FL X FL JOM101-603 1/2” FL X FL JOM101-604 5/8” FL X FL Model T-204 – MIP X FL JOM101-702 1/2” X 3/8” MIP X FL JOM101-703 1/2” MIP X FL

Webb# 165040 58791 178937 184941 184942 184940 164856 164857

T-CS-2000 Series

Model T-204

Jomar’s T-2000 Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP-Gas, natural and manufactured gas, LP gas/air mixtures and anhydrousammonia. They feature solid ball construction, reinforced P.T.F.E. seats, two piece standard port design. Double viton o-rings prevent stem leakage. Special 2000 psi seats available upon request.

Jomar’s Blue Cap® II Manual Gas Valve, Model T-204 is American Gas Association Laboratories design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/air mixtures. The Blue Cap® II may be used as a 150lb. steam valve/600 W.O.G.

Mfr# JOM100-953 JOM100-954 JOM100-955 JOM100-956 JOM100-958

Desc. 1/2” SS 3/4” SS 1” SS 11/4” SS 2” SS

Webb# 184958 184951 184955 184956 184957

Locking Device 100-82-3LD Series • Type 2: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Size 3/4”. • Type 3: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Sizes 1” and 11/4”. Mfr# JOM210-995 JOM210-996

Desc. Webb# 3/4” Locking Device 111377 1 – 11/4” Locking Device —

Mfr# Desc. Model T-204 – FIP X FIP JOM101-401 1/4” FIP X FIP JOM101-402 3/8” FIP X FIP JOM101-403 1/2” FIP X FIP JOM101-404 3/4” FIP X FIP

Webb# 184937 184938 184939 184935

Models T-82 – Mini Valves Are designed for steam, water, oil or gas in commercial and light industrial use. The minivalves are competitive, conventional port, constructed of heavy duty forged brass, 100% Teflon seats and gland follower with double viton o-rings, to prevent stem leakage. Sells and installs cost wise as the leaky plug type, pet cock or gage cock without the leaks. Mfr# JOM100-297 JOM100-299 JOM100-300

Desc. 1/8” F X M 1/4” F X M 1/4” F X F

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Webb# 111346 111348 151225

49

2 valves & accessories

Mfr# Desc. Model T-100 Series JOM100-701 1/4” F. IPS JOM100-702 3/8” F. IPS JOM100-703 1/2” F. IPS JOM100-704 3/4” F. IPS JOM100-705 1” F. IPS JOM100-706 11/4” F. IPS JOM100-707 11/2” F. IPS JOM100-708 2” F. IPS JOM100-709 21/2” F. IPS JOM100-710 3” F. IPS Model S-100 Series JOM100-803 1/2” C X C JOM100-804 3/4” C X C JOM100-805 1” C X C JOM100-806 11/4” C X C JOM100-807 11/2” C X C JOM100-808 2” C X C JOM100-809 21/2” C X C

Models T-204


SECTION

2

Ball Valves Gas Ball Valves (continued) Model T-203 Equipped with all the features of the Blue-Cap®, the System-3 has additional features making it the best value on the valve market today. • A 1/8” NPT side tap allows a manometer to be inserted into the valve to test line pressure, eliminating the test tee and the labor to install it. • It can be used in temperatures down to -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The handle can be reversed into a locked position. Combined with the tamper proof screw, the possibility of unauthorized use is sharply reduced. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • UL Listings: LP-Gas, flammable liquids, natural and manufactured gas, air, N2, inert gases including helium and CO2. • The valve is rated 150 WSP/600 WOG. Remove the plug and you have a drainable ball valve for any fluid system.

T-2000N Series Carbon Steel Jomar’s T-2000N Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP-Gas, natural and manufactured gas, LP-Gas air mixtures and anhydrous–ammonia. They feature solid ball construction, 2nd generation P.T.F.E. seats, two piece standard port design. Double Viton O-Rings prevent stem leakage. Special 2000 PSI seats available upon request. • Conforms to federal specification WW-V-35. • Latch-Lock Feature: Valve comes complete with latch lock, which may be locked in open or closed position. • Pressure Rating: 2000 W.O.G.

Mfr# Desc. Webb# Model T-CS-2000N-SS JOM100-953 1/2” 184958 JOM100-954 3/4” 184951 JOM100-955 1” 184955 JOM100-956 11/4” 184956 JOM100-958 2” 184957

Dimension in Inches Mfr# Desc. Webb# Model T-203 – FIP X FIP JOM102-301 1/4” FEM Side Tap 178938 JOM102-302 3/8” FEM Side Tap 151303 JOM102-303 1/2” FEM Side Tap 151304 JOM102-304 3/4” FEM Side Tap 151305 JOM170-105 1” FEM Side Tap 178939 Model T-203 – FL X FL JOM102-402 3/8” FL Side Tap 151306 JOM102-403 1/2” FL Side Tap 151307 JOM102-404 5/8” FL Side Tap 151308 JOM102-405 1/2” FEM X FL Side Tap 167285

size a b c d

CV*

1/4”

2.07

0.37

1.76

4.33

6.8

3/8”

2.07

0.37

1.76

4.33

6.8

1/2”

2.34

0.50

1.92

4.33

9.8

3/4”

2.80

0.69

2.40

5.83

25

1”

3.23

0.87

2.56

5.83

35

11/4”

3.57

1.00

2.74

7.76

47

11/2”

4.04

1.25

2.98

7.76

81

2”

4.63

1.50

3.17

7.76

105

* The CV Factor is the gallons of water per minute passed through the valve with 1 PSI pressure drop.

50

Gas Equipment Catalog

victormfg.com


SECTION

2

Ball Valves Apollo Valves Made In The USA

Mfr# SIZE Webb# 70 Series With Tee-Handle APO7010307 1/2” 54031 54032 APO7010407 3/4” APO7010507 1” 54033 359 APO7010607 11/4” 360 APO7010707 11/2” APO7010807 2” 361

Mfr# SIZE Webb# 80 Series Lever Handle – UL Listed for Propane APO80103 1/2” 55189 3/4” 55190 APO80104 APO80105 1” 55191 55192 APO80106 11/4” 55193 APO80107 11/2” APO80108 2” 55194

valves & accessories

Lockable Valve for Meter

With tamper proof locking cover. s.80 NPT — 3/4” & 1”

• Special design. • Hot forged brass. • Pure Teflon® seats. • -40°F +350°F temperature. • Approved by AGA & CGA to ASME. B16.33 & AGA Req’t #3-88. • Full port to DIN 3357 for maximum flow. • Double seal system allows valve to be operated in either direction making installation easier. • Two Viton 0-rings at the stem for maximum safety. • No maintenance ever required. • 600 PSI non-shock cold working pressure.

cODE s80e41 s800f41 3/4” 1” D L 2.519 3.188 H 1.801 1.958

Mfr# description webb# 250084 S80E41 3/4” Lockable Valve S80F41 1” Lockable Valve 250085 378023 S80G41 11/4” Lockable Valve 378025 S80H41 11/2” Lockable Valve S80I41 2” Lockable Valve 378026

Rub Brass Locking Gas Shutoffs MFR#

80 Series

VCTS80E41 VCTS80F41 VCTS80G41 VCTS80H41 VCTS80I41 MFR#

8043 Series

VCTS80E43 VCTS80F43 VCTS80G43

Description

Webb#

3/4”

11/4” 11/2” 2”

250084 250085 378023 378025 378026

Description

Webb#

3/4” With Union

378021 378022 378024

1”

1” With Union 11/4” With Union

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

2

51


SECTION

2

Ball Valves

High Pressure Meter Valves — Plug Style

Safe Ball®

The Gas Stops Here! Model 175 LWN & Model 175 LWIN

• Gases: Natural or LP-Gases. • Service Designation: 175 PSIG. • Options: Test Tap at inlet, brass or painted finish. • 100% Leakage Testing: at 1.5 times service designation (263 PSIG); test methods meet or exceed D.O.T and ANSI B16.33. • ISO-EN 9002: Certified. • Threads Conform: To ANSI B1.20.1. • Warranty: 10 years against leakage under normal operating conditions.

Tamperproof • 175 PSIG Flat Head • Lockwing

560B Black Iron Body

560B Black Iron Body

3/4”, 1”, 11/4”, 11/2”, 2”

1/2”, 3/4”, 1”, 11/4”

MFR# dESC. WEBB# 184925 AYM560B-8 1/2”

MFR# dESC. WEBB# 184924 AYM560B-34 3/4”

High Pressure Meter Valves — Ball Style

Model 175 LWN

Model 175 LWiN

Tamperproof • 175 PSIG • Patented Flat Head • Lockwing

Mfr# Desc. Brass Locking Meter Valve With Union JOM241-004B 3/4” JOM241-005B 1”

Webb# 276314 —

Pressure Tap Optional

760B

Special Order

6276B MFR# dESC. WEBB# 216737 AYM6276B-34 3/4” AYM6276B-1 1” 216738 216739 AYM6276B-114 11/4”

Chicago Faucets Chicago Faucets multiple service valves enable the user to access virtually any laboratory gas. Solid brass construction with a high-gloss polished chrome finish and color coded handle index buttons. • Ball valve. • E7 – Removable serrated hose nozzle. • Air, gas and vacuum buttons. • 3/8” NPT male inlet thread. • 124 PSI or approximately 29.9” Hg vacuum. Mfr# Desc. Laboratory Gas Valve CFC909AGVCP 3/4” NPT Inlet

52

Webb# 117590

Gas Equipment Catalog

victormfg.com


SECTION

2

Excess Flow, Check, Filler, Vapor Equalizing Valves Excess Flow Valves for Liquid or Vapor Line Service Designed for top installation, in any position, in liquid or vapor service lines. They are intended for long lines or branch piping where tank mounted excess flow valves cannot suffice.

2

Approximate Closing Flows Body Material

MFR#

1519A2 A1519A2 1519A3 1519A4 A1519A6

Inlet Connection NPT

Outlet Connection F. NPT

Wrench Hex Flats

1”

1”

13/4”

11/2” 2” 3”

11/2” 2” 3”

21/4” 3” 4”

Brass Steel Brass Steel

Liquid (GPM Propane)

Vapor SCHF (Propane) 25 PSIG Inlet

100 PSIG Inlet

25

5,000

8,800

60 100 225

11,500 19,000 45,000

20,200 34,500 82,000

Webb#

162410 273805 275127 189125 —

Excess Flow Valves for Liquid or Vapor Designed for liquid or vapor use for filling, withdrawal and vapor equalizing in container or line applications. They are intended for long lines or branch piping where tank-mounted excess flow valves are inadequate.

3282C

MFR#

12472 3272E 3272F 3272G A3272G 3282A 3282C A3282C 7574 3292A A3292A 3292B A3292B A3292C

Body Material

Brass

A Inlet Connection NPT

3/4”

B Outlet Connection F. NPT

3/4”

C Wrench Hex Flats

1”

D Effective Length (Approx.)

1”

Steel Brass

11/4”

11/4”

2”

115/16”

11/2”

11/2”

21/4”

13/4”

Steel Brass Steel Brass Steel

2”

2”

2”

1”

Approximate Closing Flows* Vapor SCHF (Propane) Liquid (GPM Propane)

25 PSIG Inlet

100 PSIG Inlet

4 10 15

1,050 2,100 2,800

1,700 3,700 5,000

20

3,700

6,900

30

5,850

10,000

50

9,000

16,300

90

15,200

28,100

75

14,200

24,800

100

18,100

32,700

122

22,100

37,600

Webb#

186803 162452 162453 162584 162585 162586 186857 162587 162480 189148 — 162588 162589 162590

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

53

valves & accessories

A1519A6


Excess Flow, Check, Filler, Vapor Equalizing Valves

SECTION

2

Excess Flow Valves for Liquid or Vapor Service Designed for top mounting in storage tank manhole covers for liquid or vapor applications. The tapped inlet allows for an optional 1” NPT dip pipe connection to withdraw liquid from the top of the tank. The 1519C4 is designed for installation in long line or branch piping applications.

1519C4 Approximate Closing Flows MFR#

1519C4

Inlet Connection NPT

filling Connection F. NPT

Wrench Hex Flats

2” Female

2”

3”

Vapor SCHF (Propane) liquid (gpm propane)

25 PSIG Inlet

100 PSIG Inlet

170

28,590

48,600

Webb#

162411

NOTE: Multiply flow rate by .94 to determine liquid butane flow.

Excess Flow Valves for Container Service Designed for mounting in threaded full or half couplings in container installations. They may be used for filling, withdrawal or vapor equalizing applications. The exceptionally low pressure drop makes them ideal for pump suction lines. If a riser pipe to the vapor space is used with these valves, the minimum inside diameter of the riser must be at least two times the valve thread size in order not to restrict flow to the side inlet ports.

A7537N4F

MFR#

A8523 A7537L4F A7537N4 A7537N4F A7537P4 A7537P4F A7539R6F A7539T6 A7539T6F A7539V6 A7539V6F

For Use With This Type Coupling Half Full Half Full Half Full Full Half Full Half Full

Approximate Closing Flows* Inlet Connection M. NPT

Outlet Connection NPT

Wrench Hex Flats

3/4”

3/4” Male

1”

2”

2” Male and 11/4” Female

2”

3”

3” Male and 2” Female

33/4”

Liquid (GPM Propane)

Vapor SCHF (Propane) 25 PSIG Inlet

100 PSIG Inlet

15 75

5,170 13,000

8,800 25,600

125

25,000

42,500

150

30,500

52,000

150

32,100

55,500

200

39,400

68,300

250

51,100

88,700

Webb#

187082 — 189216 — 162594 162595 189217 187043 162473 275006 189219

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow.

54

Gas Equipment Catalog

victormfg.com


SECTION

2

Excess Flow, Check, Filler, Vapor Equalizing Valves Excess Flow Valves for Vapor or Liquid Designed especially for filling, withdrawing or vapor equalizing in half and full coupling installations. Ideal for container service where welded-in dip pipes are not provided. For vapor use, mount in the bottom opening with a threaded dip pipe. For liquid use, mount in the top opening with a threaded dip pipe. These may also be installed in pipe lines provided the connection is made to the male inlet thread and not the female dip pipe connection.

Approximate Closing Flows*** Inlet Connection NPT

Outlet Connection F. NPT

Wrench Hex Flats

A2137A

2”*

27/16”

2139 2139A

2” Male and 11/4” Female

3”**

3” Male and 2” Female

31/2”

MFR#

Liquid (GPM Propane)

Vapor SCHF (Propane)

Webb#

25 PSIG Inlet

100 PSIG Inlet

70

14,000

25,000

162415

125 160

26,500 32,700

46,000 57,200

— 308180

* 11/4” F. NPT Dip Pipe Connection ** 2” F. NPT Dip Pipe Connection *** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

Excess Flow Valves for Liquid or Vapor Withdrawal These valves are designed for bottom mounting in consumer storage tanks for liquid service. They may also be top mounted for vapor service. These valves are designed especially for use with RegO® globe and angle valves.

A8013D Approximate Closing Flows** MFR#

A8013D A8013DA 2723C

Inlet Connection NPT

11/4” 11/4”

Outlet Connection F. NPT* 3/4”

1” 3/4”

Wrench Hex Flats

1” 111/16”

Liquid (GPM Propane) 39 44 20

Vapor SCHF (Propane) 25 PSIG Inlet

100 PSIG Inlet

8,700

14,700

3,900

6,900

Webb#

187071 162491 162418

* 3/4” F. NPT Dip Pipe Connection ** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

55

valves & accessories

A2137A

2


Excess Flow, Check, Filler, Vapor Equalizing Valves

SECTION

2

Excess Flow Valve for DOT Cylinders Designed for use on portable systems with vapor or liquid including torches, heaters, lead melting burners, tar and asphalt burners, wallpaper steamers and other applications involving portable DOT cylinders. The POL inlet attaches directly to the cylinder valve and the outlet mounts to the regulator. 3199W Approximate Closing Flows* MFR#

3199W

Inlet Connection NPT

Outlet Connection F. NPT

Wrench Hex Flats

Male POL

1/4”

7/8”

Vapor SCHF (Propane)

Liquid (GPM Propane) .95

25 PSIG Inlet

100 PSIG Inlet

265

500

Webb#

186856

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

Excess Flow Valve for Presssure Gauges Designed for container use in pressure gauge installations to minimize excess gas discharge in the event the pressure gauges is sheared. A suitable shut-off valve should be installed between this valve and the pressure gauge to allow convenient gauge replacement.

2884D Approximate Closing Flows* MFR#

Inlet Connection m. NPT

Outlet Connection F. NPT

Wrench Hex Flats

3/4”

1/4”

11/16”

2884D

Liquid (GPM Propane)

Vapor SCHF (Propane) 25 PSIG Inlet

100 PSIG Inlet

60

110

N/A

Webb#

186836

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

Excess Flow Valve for Flange Mounting in Container Service Designed for container use in pressure gauge installations to minimize excess gas discharge in the event the pressure gauges is sheared. A suitable shut-off valve should be installed between this valve and the pressure gauge to allow convenient gauge replacement.

A3500P4

MFR#

A3500P4

Approximate Closing Flows*

Inlet Connection NPT

For Installation

2”

Slotted Body

Liquid (GPM Propane) 150

Vapor SCHF (Propane) 25 PSIG Inlet

100 PSIG Inlet

30,500

52,000

Webb#

162591

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

56

Gas Equipment Catalog

victormfg.com


SECTION

2

Excess Flow, Check, Filler, Vapor Equalizing Valves 7590U and 7591U Check-Lok® Valves

7590U With Cap Inlet Connection

Outlet Connection

Body Wrench Hex Flats

Approximate Effective Length

Cap Wrench Hex Flats

Approximate Closing Flow, Liquid GPM (Propaine)*

3/4” M. NPT 11/4” M. NPT

1” UNF

1” 13/4”

17/16” 111/16”

15/16”

20 35

7590U 7591U 8594-1A 7590U-6 7590U-5A

Webb# 162748 204901 186981 372640 378311

Nylon Gasket O-Ring Brass Cap

* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.

Union Style Adapters for 7590U and 7591U The 7590U-10 adapter must be used to connect to the 7590U and 7591U Chek-Lok. This insures a proper connection to open the check mechanism. A built in nylon gasket provides a gas tight seal. 7590U—10 Union Style Adapter

MFR# 7590U-10

Inlet Connection

Outlet Connection

Wrench Hex Flats

Webb#

1” UNF

3/4” F. NPT

13/4”

162762

Check-Lok® Liquid Evacuation Adapter for 7590U and 7591U Valves Designed specifically for use with RegO® 7590U and 7591U Check-Lok® Excess Flow Valves. Adapter’s operating handle opens and closes equalizing stem in the Chek-Lok® valve. Eliminates gas flow through Check-Lok® valve when installing or removing adapter. Use of RegO® adapter ensures proper connections and opening of the check mechanism. 7590U-20 MFR# 7590U-20 8594-3A

Inlet Connection

Outlet Connection

A Wrench Hex Flats

B Approximate Length

15/8” F. UNF

3/4” F. NPT

13/4”

41/8”

Webb# 217164 189195

Plug

7572FC and 7580FC Check-Lok® Valves Design is the original Check-Lok. It has provided the LP-Gas industry with quality and dependable performance for over 35 years. These adapters must be used to connect to the 7572FC and 7580FC Check Loks to open the check mechanism properly. A built in nylon gasket provides a gas tight seal. 7572C-14A

7572C-15A

MFR# 7572C-14A 7572C-15A

Inlet Connection 3/4” M. NPT

Outlet Connection 3/4” F. NPT 3/4” M. NPT

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Wrench Hex Flats

Webb#

1”

162761 162478

57

2 valves & accessories

MFR#

Designed with unique 1” NPS threads on both Chek-Lok® outlet and adapter inlet. This helps prevent activation of the Chek-Lok® without use of the 7590U-10 adapter. Extra strength connection between body and adapter provides increased strength. An o-ring seal on adapter provides a gas tight seal before the adapter opens the equalizing stem. These Chek-Loks® are also designed for use on permanent installations provided the excess flow valve is sized properly for the system and piping. NOTE: In some cases, it may be necessary to use an in-line excess flow valve to protect the downstream piping. This valve is not recommended for use as a liquid source for pumps.


SECTION

2

Excess Flow, Check, Filler, Vapor Equalizing Valves Double Check Filler Valves

RegO® Double-Check Filler Valves incorporate a resilient upper check valve, normally designated as a filler valve, and a lower check valve, commonly called a back pressure check valve. Available in a range of sizes to cover virtually all LP-Gas storage containers, these valves are UL listed and meet NFPA standards, as well as other safety requirements. Flow of liquid into the storage container opens both check valves. When flow stops, they both are designed to close automatically to permit the operator to disconnect the hose coupling. The automatic closing action also helps prevent the discharge of container contents in the event of hose failure. The lower back pressure check affords extra protection by restricting the discharge if the upper check fails to function properly due to accidents or other causes. The double back check construction allows emergency inspection, repair, or replacement of the upper fill assembly without removing product from the container. When the upper filler valve body is removed, the lower back check valve provides a seal, permitting only some leakage, allowing a new upper filler valve body to be installed.

Flat Gaskets Buna-N MFR# A2797-20R A2697-20R A3184-8R A3194-8R

ACME

quantity

Webb#

11/4” 13/4” 21/4” 31/4”

25 Pack 25 Pack 20 Pack 10 Pack

187010 187009 187015 162538

Double Check Filler Valves for Forklift, Motor Fuel and RV Tanks Designed to provide fast filling of forklift, motor fuel, and recreational vehicle tanks.

7647SC

MFR#

(With Lanyard & Cap)

A Hose Connection

B Tank Connection M. NPT

C Wrench Flats

D Effective Length

13/4” ACME

3/4”

11/2” 13/4”

31/16” 21/4”*

7647SA** 7647SC*

(Approx.)

Propane Liquid Capacity at Various Differential Pressures (GPM)*** 10 20 30 40 50 PSIG PSIG PSIG PSIG PSIG 14

20

24

27

50

Webb#

190841 162756

* Larger 13/4” hex wrench flats. ** 30º angle on 11/4” ACME hose connection. *** Multiply flow rate by .94 to determine liquid butane capacity.

Double-Check Filler Valves for Large Motor Fuel and ASME Tanks 7579 6579 MFR# Cap Only

Cap, Chain and Ring

7579 7579P* 6579**

7579C — 6579C**

Designed to provide fast filling of large motor fuel and ASME domestic tanks. The 6579 Series incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations.

ACME Hose Connection

Tank Connection M. NPT

Wrench Hex Flats

13/4”

11/4”

1”

Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG

10 PSIG

25 PSIG

50 PSIG

75 PSIG

50 37 78

70 52 110

111 82 174

157 116 246

192 142 301

Webb#

162745 189180 162467

* Incorporates 3/4 F. NPT dip pipe connection. **Swing-away lower back check valve design for higher filling rate. NOTE: Multiply flow rate by .94 to determine liquid butane capacity.

58

Gas Equipment Catalog

victormfg.com


SECTION

2

Excess Flow, Check, Filler, Vapor Equalizing Valves Double Check Vapor Equalizing Valves for ASME and DOT Containers Designed to facilitate loading operations by providing equalization of pressures in the supply and storage containers. The supplementary excess flow valve closes when the flow from the container being filled exceeds a predetermined rate. The 7573 Series is designed for use in bulk delivery systems and motor fuel containers. The 3183AC is designed for use in delivery trucks and other large containers.

7573DC

Basic

With Chain & Cap

7573D —

7573DC 3183AC

ACME Tank Hose Connection Connection M. NPT 11/4” 13/4”

Wrench Hex Flats

3/4” 11/4”

Approx. Closing Flow at 100 PSIG Inlet Webb# Pressure (SCFH/Propane)

11/4” 2

4,100 10,000

162744 250112

Double Check Filler Valves for Delivery Truck Tanks and Large Storage Designed to provide fast filling of bobtails, transports and large bulk storage tanks. The 6587CD incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations.

7579S

MFR#

ACME Hose Connection

Tank Connection M. NPT

Wrench Hex Flats

7579S

13/4”

11/2”

2”

Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG

10 PSIG

25 PSIG

50 PSIG

75 PSIG

44

62

98

139

170

Webb#

162481

Back Pressure Valves for Container or Line Applications Designed to provide protection of a container opening when desired flow is always into the vessel. May be used in line applications where flow must be limited to one direction. When used with the appropriate single check fill valve, the combination forms a double check filler valve suitable for use in filling of bulk storage tanks.

3146 MFR# Brass

Steel

3146 — 3176 — — —

— A3146 — A3176 A3186 A3196

Propane Liquid Capacity at Various Differential Pressures (GPM)

A Inlet Connection F. NPT

B Outlet Connection M. NPT

C Wrench Hex Flats

D Effective length (approx.)

5 PSIG

10 PSIG

25 PSIG

50 PSIG

3/4”

3/4”

13/8”

115/16”

11

16

25

36

11/4”

11/4”

2”

13/8”

28

40

63

89

2” 3”

2” 3”

27/8” 4”

27/16” 315/16”

124 297

175 420

276 664

391 939

Webb#

162578 187012 162580 162581 162582 162583

Back Pressure Check Valves RegO® Back Pressure Check Valves are designed to allow flow in one direction only. The check, normally held in the closed position by a spring, precludes the possibility of flow out of the container. When flow starts into the container, the pressure overcomes the force of the spring to open the check. When the flow stops or reverses, the check closes. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

59

valves & accessories

MFR#

2


Excess Flow, Check, Filler, Vapor Equalizing Valves

SECTION

2

Single Check Filler Valves for Storage with Supplementary Back Check Valves Designed for use with RegO® Back Check Valves to provide fast filling of bulk storage tanks. Also may be used as a spare or replacement part. These single check filler valves must never be installed directly into container couplings. They must be used with the appropriate back check valve to comply with NFPA Pamphlet #58. 3174C

MFR#

ACME Hose Connection

Outlet Connection M. NPT

Wrench Hex Flats

13/4” 31/4”

11/4” 3”

13/4” 31/2”

3174C 3194C

Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG

10 PSIG

25 PSIG

50 PSIG

23 147

33 208

52 329

74 465

For Use With Back Check Valve

Webb#

3176 A3196

189144 189146

Vapor Equalizing Valves RegO® Vapor Equalizing Valves consist of an upper back check valve and lower excess flow valve. In the closed position, the attachment of a vapor hose coupling with its projecting nozzle, opens the back check valve to permit flow in either direction. The lower excess flow valve is designed to close automatically when flow out of the container being filled exceeds the rated capacity. The valve closes automatically when the coupling is removed. Like the double-check filler valves, the vapor equalizing valves utilize a two-piece body construction. The lower excess flow valve will permit some leakage when the upper back check valve is removed for emergency repairs or replacement. RegO® Vapor Equalizing Valves are designed for use in both ASME and DOT containers.

Flat Gaskets Buna-N MFR# A2797-20R A2697-20R

ACME

quantity

Webb#

11/4” 13/4”

25 Pack 25 Pack

187010 187009

Single Check Vapor Equalizing Valves for ASME and DOT Containers with Supplementary Excess Flow Valves

3170

MFR# Basic

With Chain & Cap

3170 -—

— 3180C

60

Designed for use with RegO® Excess Flow Valves to facilitate loading operations by providing equalization of pressures in the supply and storage containers. Also may be used as a spare or replacement part. These vapor equalizing valves must never be installed directly into container couplings. They must be used with the appropriate excess flow valve to comply with NFPA Pamphlet #58.

Inlet Connection

Outlet Connection

Wrench Hex Flats

Approx. Closing Flow at 100 PSIG Inlet Pressure

11/4” 13/4”

3/4” 11/4”

11/4” 13/4”

7,600 10,000

Gas Equipment Catalog

Webb#

(SCFH/Propane Vapor) 189142 189145

victormfg.com


SECTION

2

Excess Flow, Check, Filler, Vapor Equalizing Valves Bronze Swing Check Valves Class 300 — Y-Pattern — Threaded Ends

Features: • Screwed Cap. • Always install with pressure under the disc in vertical or horizontal position. An arrow cast on the body indicates the correct direction of flow. • MSS-SP-60. Type 3. Working Pressures Non-Shock: 300 psi Steam, Basic Rating. 1000 psi Cold Working Pressure – 1/4” to 2” (6mm – 50mm). 600 psi Cold Working Pressure – 21/2” to 3” (65mm – 80mm).

valves & accessories

Swing Check Valve

2

mfr# webb# CRV76E-38

6143

CRV76E-12

6144

CRV76E-34

6145

CRV76E-1

6146

CRV76E-114

6147

CRV76E-112

6148

CRV76E-2

6149

Bronze Lift Check Valves Class 300 — Threaded Ends

Features: • MSS-SP-80, Type 1. Suggested to be used on a compressor or similar application with constant pulsating supply. Must be installed horizontally only. Working Pressure Non-Shock: 300 psi Steam, Basic Rating. 1000 psi Cold Working Pressure.

Lift Check Valve

mfr# size webb# CRV366E-34

1/4”

CRV366E-1

1”

CRV366E-114 11/4”

CRV366E-112 11/2”

CRV366E-2

2”

6159

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

61


SECTION

2

Internal Valves & Accessories

11/4” Threaded Internal Valve for Small Capacity Pumping Systems and Bobtail Vapor Equalization Designed primarily for use with LP-Gas and anhydrous ammonia as a main valve on small capacity pumping systems, NH3 nurse tanks and in-line installations. It may also be installed in the vapor equalizing opening on bobtail delivery trucks. Installation is quick and easy, and it fits in both full and half couplings, as well as, in-line applications. The valve may be activated manually by hand or cable. A3209D050

MFR# A3209D050 A3209D080

Inlet Connection M. NPT

Outlet Connection F. NPT

11/4” 11/4”

11/4” 11/4”

Closing Flow (GPM) LP Gas 50 80

LP Gas Vapor Capacity SCFH/Propane

Accessories

NH3

25 PSIG Inlet

100 PSIG Inlet

Thermal Latch

Pneumatic Actuator

45 72

13300 15700

22900 26700

A3209TL A3209TL

A3209PA A3209PA

Webb#

251120 251118

Flomatic® Internal Valves for Bobtail Delivery Trucks, Transports and Large Stationary Storage Tanks A7883FK MFR# A7883FK A7884FK

62

Designed primarily for LP-Gas and anhydrous ammonia liquid withdrawal on MC331 bobtail delivery trucks, transports and large stationary storage containers with flanged connections. The valve is fully automatic, opening and closing as the pump is turned on or off.

Inlet Connection ANSI Flange

Outlet Connection ANSI Flange

Strainer Width

Base Width

Overall Height (Approx.)

Height from Indicator to Base

Filter

3-Way Valve

3” - 300# 4” - 300#

3” - 300# 4” - 300#

43/4” 53/4”

81/4” 10”

107/8” 111/4”

413/16” 415/16”

A7884201

A7853A

Gas Equipment Catalog

Accessories

Webb# 162571 193215

victormfg.com


SECTION

2

Internal Valves & Accessories Threaded Internal Valves for Bobtail Delivery Trucks, Transports and Stationary Storage Tanks Designed primarily for use with LP-Gas and anhydrous ammonia for liquid withdrawal; vapor transfer or vapor equalization of bobtail delivery trucks, transports, stationary storage tanks, and in-line installations. The valve may be operated manually by cable or pneumatically.

A3212R105

A3212R105 A3212R250 A3212R250-115 A3213R150 A3213R300 A3213R400

Inlet Connection M. NPT

Outlet Connection F. NPT

2”

2”

3”

3”

Closing Flow (GPM) Full Coupling MFR#

A3212R105 A3212R250 A3212R250-115 A3213R150 A3213R300 A3213R400

LP Gas

NH3

65 130 — 125 250 325

59 117 — 113 225 293

Closing Flow (GPM) Half Coupling LP Gas

NH3

105 250 — 150 300 400

95 225 — 135 270 360

Accessories Thermal Latch

Pneumatic Actuator

rotary pneumatic actuator

A3212TL #189207

A3213PA #162570

A3212RA

A3213TL #189208

A3213PA #162570

A3213RA

Webb#

189206 187019 — 190677 187020 162569

T Series MFR# A3212RT250 A3213T300 A3213T400

Inlet Connection M. NPT

Outlet Connection F. NPT

2”

2”

3”

3”

Closing Flow (GPM) Half Coupling LP Gas

NH3

250 300 400

— — —

Webb# 273831 224357 251119

ESV Pneumatic Controls MFR# 7781AFPN-1 6016-60D 7605PN-50

7605PN-50

7605APN-8A 7605A-BT 7605AP-16 7605AP-15 7605AP-12 P/HPPB430500 P/HA4MC4MG P/HA4TU4MG P/HA4UC4MG

Description

Webb#

Cylinder assembly kit to convert 7781AF ESVs to pneumatic shutdown. Cylinder assembly kit to convert 6016 ESVs to pneumatic shutdown. Pneumatic remote shutdown system kit, complete with 100’ of tubing, fittings, 1 charging valve assembly and 1 remote shutdown valve assembly. Extra shutdown valve assembly. 100’ roll of 1/4” pneumatic tubing. 1/4” tubing tee, with nuts. 1/8” NPT x 1/4” tubing, straight connector. Charging Valve Assembly 1/4” tubing (per foot) 1/4” NPT x 1/4” tubing, stright connector 1/4” tubing tee with nuts 1/4” tubing union

241753 359336

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

189185 246564 189182 186935 186934 266444 228691 228953 228973 228974

63

valves & accessories

MFR#

2


SECTION

2

Adapters, Connectors & Fittings Short Type Hose Couplings for Vapor and Liquid Service

Style A For Liquid Filling

Style C For Vapor Equalizing

MFR#

Material

3175B 3175 3175A 3185

Brass

3195

Style B For Liquid Filling

Style D For Vapor Equalizing

A3175 A3175A A3185 A3195 3171A 3181 3181A 3191

Style A

Brass Nut and Steel Nipple

B

Hose Connection M. NPT 1/2” 3/4” 1” 11/4”

Coupling Connection F. ACME

2”

31/4” 13/4”

1”

11/4” 2” 1/2“ 3/4” 1” 11/4”

B C

Brass

21/4”

3/4”

A

Steel

13/4”

D

MFR#

Tailpiece Bore

3175B 3175 3175A 3185 3195 A3175 A3175A A3185 A3195 3171A 3181 3181A 3191

35/64”

21/4” 31/4” 11/4” 13/4” 21/4”

Hose End To Nut

Overall Length

2”

2”

13/16” 113/16”

21/16” 2”

3” 3”

3/4”

2”

2”

13/16” 113/16” 17/32” 11/16” 15/16” 3/16”

2” 2’

3” 3”

13/16” 2” 1” 2”

27/16” 31/4” 3” 35/16”

3/4”

Webb# 186853 162687 162688 186854 162692 257541 162689 187016 162693 162686 162690 162691 186855

ACME Check Connectors for Lift Trucks

7141M

7141F

These brass connectors are especially designed to join the carburetor fuel line to the service valve on lift truck cylinders. Sturdy, long lasting ACME threads allow quick, hand-tight assembly that provides for quick and simple cylinder replacement. Back checks automatically close in each connector when disconnected. The 7141M couples directly to the service valve. An integral O-ring is designed to seal before the internal check opens, aiding in product loss prevention. A gasket at the ACME thread is a secondary seal when the connectors are tightened together. The connector fits RegO® lift truck cylinder filling adapters for fast, convenient filling. The 7141F accepts fuel line adapter and couples directly to the 7141M. The O-ring seal in the 7141M is designed to seal before the internal check opens to allow product to pass through the connection. The knurled coupling eases threading and the ACME threads provide rapid effortless make-up, even against LP-Gas pressure.

MFR#

Application

Inlet

Outlet

7141M 7141F

Service Valve Fuel Line

3/8” F. NPT 11/4” F. ACME

11/4” M. ACME 1/4” F. NPT

Protective Cap* Rubber

Brass

7141M-40 —

7141FP —

Webb# 162755 162754

* Recommended to minimize foreign material entering valves which could result in leakage.

64

Gas Equipment Catalog

victormfg.com


SECTION

2

Adapters, Connectors & Fittings Unloading Adapters for Container Evacuation Designed to provide an efficient means of evacuating an LP-Gas container for relocation or repair. They thread directly onto the 13/4” ACME male hose connection of RegO® Filler Valves used on RegO® Double Check Filler Valves and Multivalves®. The unloading adapters can be used to withdraw liquid provided the container is equipped with a dip pipe extending from the filler valve to the bottom of the container. Style

3119A 3120 3121

In-Line

A Filler Valve Connection

B Hose Connection

Webb#

13/4” F. ACME

162830 162831 263104

13/4” F. ACME

Angle

3/4” F. NPT

3120

Extended Type Hose Couplings for Vapor and Liquid Service

3121

A7575L

Designed especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of the handle on the tailpiece minimizes spin-off, encouraging cautious removal to properly bleed off trapped product to assure closure of the filler valve and hose end valve. The ACME threads are machined on a rugged steel insert which is permanently cast in the aluminum handle, providing for durability under repeated use. MFR# A7575L2* A7575L3 A7575L4 A7571LB

Type of Service

Hose Connection M. NPT

Coupling Connection F. ACME

Approx. Length

Webb#

7”

275141 162710 162711 189221

1/2”

Liquid

3/4”

13/4”

1” Vapor

3/4”

11/4”

* Includes 7199-33 adapter, shipped loose.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

65

valves & accessories

3119A

MFR#

2


SECTION

2

Adapters, Connectors & Fittings Filler Hose Adapters

These adapters are designed with minimal flow restriction and recommended for use on the outlet of the LP-Gas delivery truck filler hose. If the controlled bleed off of the connection indicates the filler valve on the tank being filled has failed to close, the hose adapter should be left in place on the filler valve and disconnection should be made at the regular filler hose coupling. (Repair of the filler valve must be made as soon as possible). An integral check valve in these adapters helps prevent further loss of product. The standard filler valve cap should be attached to these adapters when left on the container.

3179B 7577V

MFR#

Built-In Vent Valve

Filler Valve Connection

Hose Connection

Propane Liquid Capacity at 80 PSID

Webb#

7577V 3179B 7576

Yes No Yes

13/4” F. ACME

13/4” M. ACME

57 GPM

162764 162763 —

ACME Adapters MFR#

Gasket (Furnished with adapter)

ACME X Female NPT

Material

A M. ACME

Brass

A5764D

Steel

13/4”

MFR#

Material

ACME X Male NPT

5765D 5765E 5767F 5767G 5767H 5769H 5769K A5765C A5765D A5765E A5765F

D

E Diameter

13/4”

1/2”

13/4”

3/4”

1” 1”

For Spare Gasket order MFR#

11/2”

3/8”

1”

3/4”

a269720r

187009

21/4”

25/16”

1”

A31848R

187015

31/2”

3”

2”

A31948R

162538

1”

13/4”

23/16”

3/4”

a269720r

187009

A M. ACME

B M. NPT

C Hex

D

E Diameter

11/4”

3/4”

11/4”

13/4”

7/16”

13/4”

1” 2”

11/16”

21/4”

25/16”

2” 3” 31/2”

27/16” 2” 3”

13/4”

23/16”

31/4”

2”

21/4” 31/4”

13/4” Brass

21/4” 31/4”

Steel

A5769H

66

C Hex

1/4”

5764A 5764B 5764C 5764D 5764E 5766E 5766F 5768G 5768H

5763D Gasket (Furnished with adapter)

B F. NPT

Gas Equipment Catalog

13/4”

31/4”

11/4” 11/2” 2”

3/4”

1” 11/4” 11/2” 2” 2” 3” 1/2” 3/4” 1” 11/4” 2”

3/4” 13/16” 1” 125/64” 1” 2” 17/32” 11/16” 7/8” 15/16”

1”

Webb# 162464 186865 162465 186866 162698 162704 186868 194502 162705 189210

For Spare Gasket Webb# order MFR# A2797- 187010 189153 20r A2697- 187009 186867 20R 162700 189154 A3184- 187015 189155 8R 189156 A3194- 162538 162706 8R 189158 — a2697- 187009 189211 20r 162701 189212 A3194- 187015 162707 8R

victormfg.com


SECTION

2

Adapters, Connectors & Fittings ACME Adapters MFR#

Material

A M. ACME

B M. ACME

C Hex

D Diameter

13/4”

13/4”

21/16”

21/4”

21/4“

25/16”

125/64”

31/4”

1/2”

23/4”

2”

5765M 5767M

(continued)

Brass

5769M

Webb# 162703 189157 162708

MFR#

Material

A M. ACME

B F. NPT

C Hex

D Diameter

Webb#

A5764W

Steel

13/4”

11/4”

111/16”

162699

ACME Plugs (CGA 510) POL

970 Hard Nose POL

Specifically designed to withstand the everyday abuse given hose end valves on delivery trucks and hose end couplings on risers in bulk plants. These rugged plugs protect the coupling tip as well as prevent the entrance of dirt, dust, snow and rain. They also prevent possible gas contamination from these same sources. The heavily ribbed outer surface permits hand-tight make-up. MFR#

(CGA 510) POL

970HT Soft Nose POL With Handwheel

Material

C5762N C5765N 5765PR C5767N C5769N

M. ACME

Chain & Ring Fits Pipe Size Up to:

Webb#

3/4” 11/4” — 11/4” 2”

162463 162466 250302 187102 162709

11/4”

Nylon

13/4”

Brass

21/4” 31/4”

Nylon

POL Plugs Highly recommended for installation in LP-Gas cylinder valve POL outlets whenever the service line is disconnected or when the cylinder is being transported. When properly installed, the POL plug is designed to prevent contamination of the valve outlet and guards against product leakage if the cylinder valve is accidentally opened. n970p

MFR#

Material

N970P 10538P 3705RC

Cycolac Brass

Connection

Webb#

M. POL CGA 510

179491 189118 162456

Male POL Swivel Adapters (CGA 510) POL

970AX Hard Nose POL With Excess Flow

50-70 Micron Filter

3199W Heavy Duty Hard Nose POL With Excess Flow

MFR# 970 970S 970AX 970AXS 3199W 970AW 970HT 970JR

Material M. A NPT

B C Hex Drill 5/16” 3/16”

1/4”

Brass

M. NPT

1/4” Hose Barb

5/16”

1” —

3”

5/32”

D

Vapor at 100 PSIG Inlet (SCFH)

2” 23/32”

25/64”

404

1.10

27/16”

450

0.95

Liquid Webb# (GPM)

21/16” 2”

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

2

191818 162771 187003 246565 186856 187002 243117 190842

67

valves & accessories

For Spare Gasket Order MFR# a2697-20r #187009 A3184-8R #187015 A3194-8R #162538


SECTION

2

Adapters, Connectors & Fittings POL Adapters

(CGA 510) POL

2906G Male POL X Female NPT

MFR#

Material

2906A 2906G

Brass

MFR#

A M. ACME 1/4” 1/2”

1” 2”

Material

A

B

Brass

3/8” M. NPT 3/8” SAE Flare 1/2” SAE Flare

2906D 2906F 2906E MFR#

(CGA 510) POL

5760A 5760B 5760C 5760D

Male POL X Male NPT and SAE Flare

Material

MFR#

Female POL X Female NPT and Female POL

(CGA 510) POL

Female POL X Male NPT

D Diameter

Webb#

1/4”

189131 162828

C Hex

D Diameter

Webb#

15/16”

11/32”

189132

7/8”

9/32”

C Hex

D Diameter

15/16”

1”

11/16” 21/4”

A

B

1/4”

15/8”

11/8”

17/8”

13/8”

POL CGA 510

21/8”

11/8”

A

B

C Hex

13/32”

163431

D Diameter

1/4”

3/16”

3/8”

13/32”

Webb# 162457 162458 162459 162460

43/64”

3/4”

Material

162826

35/64”

1/2”

Brass

162827

13/32”

3/8”

5760S

(CGA 510) POL

C Hex

B

Webb#

5761A 5761B 5761C 5761D

Brass

MFR#

Material

A

B

C

Webb#

1494-1

Brass

12” F. NPT

1/4” F. NPT

1/2” M. NPT

162823

15/8”

1/2”

11/8”

186863 186864 162461 162462

7/16”

3/4”

Excess Flow Adapters MFR# 3188B 3188C

3188 Heavy Duty Hard Nose POL With Excess Flow

Material M. A NPT Brass

B C Hex Drill

1/2” M. NPT

1”

5/16”

D

Vapor at 100 PSIG Inlet (SCFH)

21/2”

700 1180

Liquid Webb# (GPM) 1.9 2.9

246615 246616

Miscellaneous Adapters MFR#

Material

A

B

Webb#

15774-1

Brass

1/4” M. NPT

Female Inverted Flare

162501

Test Adapters MFR# 1328 1331 1332

68

Material Brass

A

B

5/8” - 18 UNF

5/8” - 18 UNF

3/4” - 16 UNF

3/4” - 16 UNF

7/8” - 14 UNF

7/8” - 14 UNF

Gas Equipment Catalog

C HEX 1/2”

Hose Barb

D

E

F

Webb#

13/16”

2” 21/8” 21/2”

11/2”

162816 162817 162818

15/16”

11/16”

13/4”

victormfg.com


SECTION

7141FP Cap Plug

2

Miscellaneous Equipment A5776

3175P Cap Plug

Cap and Reducers

3144-91 Plastic Cap MFR#

Chain & Ring fits pipe size up to:

Cap only MFR#

Material

3144-91

3/4"

3144-9P 224434

Cycolac

1 1/4" F Acme

186849

7141FP Cap Plug

1 3/4" F Acme

907FP 189143

Nylon

F POL CGA510

189128

1 1/4" F Acme

189166

A5776 3174-9P 162832 Reducer Coupling

3174-91 3174-93 3175P

1 1/4"

Cap1708C Plug

3/4"

7141FP

A8016-9P 275116

1 1/4"

Thread Connection

Brass

1 3/4" F Acme

3175P Cap Plug

3184-90

2"

3194-90

3"

A3184-90

2"

A3194-90

3"

A5776 Reducer Coupling

7141FP A8016-9P 275116 Cap Plug 5774

2 1/4" F Acme

Steel

162694

3 1/4" F Acme

162695

1 3/4" M Acme x 3 1/4" F Acme

187024

1708 POL Cap

3144-90 Metal Cap 1708 POL Cap

3144-90 Metal Cap

3194-90G ACME Cap With Stainless Steel Flange

1708 POL Cap

CGA 555 Swivel Adapters MFR#

Material

A

B Hex

C Drill

D

Webb#

12982

Brass

1/4” M. NPT

11/4”

3/16”

115/16”

190684

1708 POL Cap

1708 POL Cap

162695

2 1/4" F Acme

3194-90G ACME Cap With Stainless Steel Flange

907FP

3144-90 Metal Cap

3 1/4" F Acme

907FP

7141FP Cap Plug

907FP

162694

2 1/4" M Acme x 3 1/4" F Acme

907FP

3144-90 Metal Cap

7141FP Cap Plug

192871

3144-90

1 3/4" M Acme x 3 1/4" F Acme 261759 Metal Cap

A5776

A5776 Reducer Coupling

2

162451

3175P 5776

Webb#

valves & accessories

3144-91 Plastic Cap

Reducer Coupling

3194-90G ACME Cap With Stainless Steel Flange

3194-90G ACME Cap With Stainless Steel Flange

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

69


SECTION

2

Miscellaneous Equipment 1” Rotogages for Large Mobile and Stationary Containers ®

Rotogages® are designed to provide an accurate determination of LP-Gas or anhydrous ammonia container contents. They mount in a standard 1” NPT coupling on large mobile or stationary containers. To operate the Rotogages®, the vent valve is opened and the dip tube rotated slowly from the container vapor space to the liquid space. The difference in appearance of the discharge indicates when the liquid level is reached. Dial readings then indicate the percentage of product in the container. MFR# webb# RGOA9091R — RGOA9092R 162597 RGOA9093RS 190686 RGOA9093TS 162598 RGOA9094RS — RGOA9094TS 162600 RGOA9095RS 162602 RGOA9095TS 162678 RGOA9091-M24.0 — RGOA9091-M36.0 162679 RGOA9091-M48.0 162680 RGOA9091-M60.0 162681 RGOA9091-M72.0 162988

MFR# A9091-18L

For Use With LP-Gas For Stationary Containers Only — — 9093RSM48 9094RSM60 9095RSM72

Container Size Webb# All Sizes Over 1200 U.S. Gallons

162682 —

* Dial permits higher filling level, as per NFPA 58, (1983) Par. 4-5.2.1, Table 4.5.2.1

For Container Inside Diameter

For Use With NH3 For Stationary For Mobile Containers or Stationary Only Containers AA9091RM24 — AA9092RM36 — AA9093TSM48* AA9093RSM48 AA9094TSM60* AA9094RSM60 AA9095TSM72* AA9095RSM72

* Supported design.

LP-Gas

A9091-18LX*

MFR# For Mobile or Stationary Containers 9091RM24 9092RM36 9093TSM48* 9094TSM60* 9095TSM72*

Service

Ellipsoidal Heads

Hemispherical HeadS

Side Mounted

End Mounted

Side Mounted

End Mounted

30” - 45” 46” - 61” 62” - 79” 80” - 99” 100” - 147”

30” - 75” 76” - 108” 109” - 147” — —

30” - 45” 46” - 61” 62” - 79” 80” - 99” 100” - 147”

30” - 45” 46” - 61” 62” - 79” 80” - 99” 100” - 147”

NOTE: The dip tube must be cut to the required length (1/2” of container inside diameter minus 5-3/4”).

Sight Flow Indicators for Bulk Plants

A7794

70

Designed to promote maximum pump efficiency, these indicators enable bulk plant operators to visually inspect liquid flow conditions. With glass on both sides of the indicator, flow can be observed from either side, even under some poor light conditions. The integral swing check also serves as a back-check valve to prevent reverse flow and product loss if the hose fails in a loading operation. By installing an indicator on the upstream side of the plant pump, suction conditions can be observed and the pump speed adjusted to obtain the maximum possible flow rate without cavitation. Additionally, if an indicator is installed in the piping at the loading rack, just ahead of the loading hose, the operator can maintain a constant check on pump conditions. Both installations are designed to allow for observation to provide maximum pump efficiency and assure safe plant pump operation. In compressor operations a sign flow indicator installed in the liquid line will give a visual indication when the tank car or transport is emptied. Compressor operation can then be immediately reversed to start recovery of the vapor. MFR#

Inlet/Outlet Connections

Length

Webb#

A7794 A7796

2” F. NPT 3” F. NPT

53/4” 7”

162712 162713

Gas Equipment Catalog

victormfg.com


SECTION

2

Miscellaneous Equipment Pull-Away Valves for Transfer Operations

A2141A6L

A2141A6 A2141A6L** A2141A8 A2141A10 A2141A16

LP-Gas Liquid Flow Capacity at Various Differential Pressures (GPM)*

Inlet/Outlet Connections NPT F.

Disconnect Force Approx-lbs

Reconnect Force Approx-Lbs

Length of Valve

3/4”

130

80

37/8”

11

16

25

36

1” 11/4” 2”

75 160 300

50 25 50

49/16” 55/8” 145/16”

21 52 250

30 75 350

47 120 550

67 170 750

5 PSIG

10 PSIG 25 PSIG 50 PSIG

Webb# 162683 162684 187008 189203 187007

* To determine NH2 liquid flow capacity, multiply by .90. ** Lanyard.

“Swing-Check” ESVs for Bulk Plants Especially designed for installation in liquid transfer lines at LP-Gas or anhydrous ammonia bulk plants to provide for quick shut-off of liquid or vapor flow in the event of an accidental pull-away or hose rupture, both of which can cause a fire. MFR#

6016 2” ESV

6024 6016 6010 MFR# 6016-60C 6016-60D

For use Only With

Inlet/Outlet Connections

Liquid Low Capacity at 10 PSIG Pressure Drop (GPM)

Webb#

LP LP LP

3” F. NPT 2” F. NPT 1¼” F. NPT

427 (NH3) 427 (NH3) 427 (NH3)

394985 308754 370270

description

Webb#

Pneumatic Open/Close Actuator Pneumatic Release for Point of Transfer

361807 359336

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

71

2 valves & accessories

MFR#

Designed especially to provide pull-away protection for LP-Gas and anhydrous ammonia transfer operations including transport and delivery truck loading and unloading, engine fuel container filling and miscellaneous cylinder filling operations. When properly fastened to the inlet end of the discharge hose, the valve is designed to stop gas escape from both upstream and downstream lines in the event of a pull-away. An excessive tension pull causes the valve to automatically separate, closing two internal back pressure checks. Only a few cubic centimeters of gas escape at the instant of separation. It is recommended that a convenient means be provided to safely remove the pressure from the line upstream of each coupling half to enable reassembly of the valve. To reassemble, simply push the male half firmly into the female half until the retaining balls slip into the retaining groove. Check for leaks after reassembly. NOTE: It is recommended that pull-away valves be safety-tested at least monthly to confirm that they will separate properly in the event of a pull-away. Dry nitrogen or other inert gas is suggested for a source of pressure during such tests.


SECTION

2

Miscellaneous Equipment

Hose End Adapters for DOT Cylinder Filling

7193D-10

Designed to provide quick and easy filling of DOT cylinders with POL or Type 1 connections. This adapter may be used with hydraulic and electric automatic systems or with manual systems in conjunction with a RegO® 7901TB Quick Acting Shut-Off valve. These filling connectors have an extended connection on the handwheel, which make it possible to connect the loading hose to valves on cylinders with fixed collars. The handwheel is well outside the collar for easy operation. mfr#

Applications

Inlet Connection

Filling of DOT Cylinders with POL Connections Filling of DOT Cylinders with Type 1 Connections

7193d-10

7193U-10 7193u-10

1/4” M. NPT

Outlet Connection

Materials

Webb#

M. Pol CGA 510

Brass & Stainless Steel

186884

Type 1 Connection (115/16” M. ACME)

Brass

186886

Connector for DOT Cylinder Filling Adapter The 7193T-10 is designed for use on the 7193D-10 Filling Adapters. Connector allows adapter to be used on the 15/16 M. ACME & F. POL connections of Type 1 valves.

7193T-10

mfr#

Applications

Inlet Connection

7193T-10

Converts 7193D-10 Adapter from POL to a Type 1 Connection

M. POL CGA 510

Outlet Connection Type 1 Connection (115/16” M. ACME)

Materials

Webb#

Brass

162472

Brass Type 1 Fittings & Adaptors Type 1 ACME Appliance Side Fitting X 1/4” Male Pipe

Appliance side swivel nut fitting is female 115/16” F. ACME X 1/4” M. NPT. As the appliance side of the Type 1 connection, it makes a positive connection by threading on to the ACME threads of the valve with a user-friendly right hand turn motion. Mfr# description

Webb#

G1855-A03

POL Green 71–200 BTU

242866

G1855-A02

POL Black 0–70 BTU

182659

G-1850 Evacuation Fitting G-1850

Threads onto Type 1 cylinder valves just like the appliance side, swivel nut fittings. For purging only. Mfr# G-1850

72

Webb# 182658

Gas Equipment Catalog

victormfg.com


SECTION

2

Miscellaneous Equipment Hose End Adapter for Lift Truck Cylinder Filling The 7193L-10A is designed to provide quick and easy attachment of the filling hose to DOT cylinders equipped with RegO® 714M check connectors. 7193L-10A

MFR#

Inlet Connection

Application

1/4” M. NPT

11/4” F. ACME

Brass

5760A

162471

* The 7193L-10A is intended to be permanently attached to the filling hose.

Lever Operated Hose End Adapter for Fork Lift Cylinder Filling Designed to drastically reduce labor and time when continuously filling large numbers of lift truck cylinders equipped with RegO® 7141M check connectors.

7193K-10B

MFR#

Application

Inlet Connection

Outlet Connection

MaterialS

Webb#

7193K-10B

Lever Operated for Quick Filling of Fork Lift Cylinders

1/4” M. NPT

Quick Disconnect York

Brass and Steel

162470

For use with RegO® 7141M check connector.

Quick Connect POL Filling Adapter The 7193R-10 is designed for use in LP-Gas filling systems including fill rooms and dispensing stations. The quick acting lever allows fast connection to POL type (CGA 510) cylinder valves. It fits both compact and heavy duty cylinder valves commonly found on 5 to 100 lbs. DOT LP-Gas cylinders.

7193R-10

MFR# 7193R-10

Application

Inlet Connection

Outlet Connection

Webb#

Lever Operated for Quick Filling of Cylinders with POL Outlet

1/2” F. NPT

Fits Female POL CGA 510

189171

Vent Valves

3165CP

3165C

Especially designed to bleed off liquid or vapor pressures trapped in transfer lines. When installed in the downstream boss of RegO® globe and angle valves used at the end of a liquid transfer hose, the bleeder valve allows for the controlled venting of the product and indicates to the operator that the valves are closed and he can disconnect the coupling. They may also be used as a fixed liquid level gauge where the dip tube is part of the container. MFR#

TSS3169

Service

3165C 3165CP

LP-Gas Only

TSS3169

LP-Gas & NH3

Connection

Actuation

1/4” M. NPT

Knurled Knurled

Accessories Warning Plate Kit

Webb#

2550-40P

162449 186852

Tee Handle

162450

Spanner Wrench for ACME Connectors This aluminum spanner wrench is especially designed for use with 21/4” and 31/4” ACME couplings, adapters and caps. 3195-50

MFR#

For Use with ACME Connector Size

Webb#

3195-50

21/4” & 31/4”

162697

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

73

2 valves & accessories

of Fork Lift 7193L-10A Filling Cylinders*

Accessories Outlet Body Connection Material Adapter Webb#


SECTION

2

Miscellaneous Equipment Fixed Liquid Level Gauges

Especially designed to provide a visible warning when containers are filled to the maximum permitted filling level. At the start of the filling operation, with the vent stem opened, the valve discharges vapor. When the maximum permitted filling level is reached, the valve discharges liquid. These valves are normally furnished with a 12”, 3/16” O.D. dip tube and incorporate a No. 54 drill size orifice. An optional instruction plate with “Stop Filling When Liquid Appears” may be ordered for use with these valves.

MFR#

Service

Connection

Actuation

Dip Tube Length

3165CF05.6 3165CF12.0

LP-Gas Only

1/4” M. NPT

Knurled Knurled

5.6” 12”

Accessories Warning Plate Kit 2550-40P

3165CF12.0

Webb# 189141 186851

Combination Valve for Bulk Storage Containers

A2805C

Designed for installation on bulk storage containers, this valve combines a pressure gauge mounting and provision for a fixed tube liquid level gauge. The shut-off valve prevents the pressure gauge from being subjected to constant pressure, thereby prolonging its life and accuracy. The valve may be closed, and the vent valve opened to vent pressure from the gauge to permit replacement. For fixed liquid level gauging, the valve can be mounted at the maximum permitted filling level. When equipped with a dip tube threaded 1/8” M. NPT, it can be installed at any convenient level. MFR#

Container Connection

Service Connection

Liquid Level Vent

Webb#

A2805C

3/4” M. NPT

1/4” F. NPT for Gauge Mounting

Knurled

162685

Needle Valves

1224WA

74

These valves are high quality, “true” throttling valves. Unlike most so-called needle valves, both the body seat and stem are tapered to provide fine, precise control over a wide range of adjustment without stem galling. The 1224 may be used as a small, inexpensive shut-off valve between a pressure gauge and bulk storage container to allow for convenient gauge replacement. The 1316 provides taper pipe thread by left hand hose connection threads and are useful in a wide range of torch and fuel burner applications where an accurate throttling action is required. MFR#

Inlet Connection

1224WA 1316WA

9/16” - 18 L.H.

1/4” M. NPT

Gas Equipment Catalog

Outlet Connection

Height

Length

Webb#

1/4” M. NPT

19/16”

13/4”

186802 189122

victormfg.com


SECTION

2

Diagrams Bulk Transport Truck

R O TO G A U

G

Vapor Return

GO

2 Liquid Fill

valves & accessories

Liquid

RE

E

Rotogage A9093TS

Spray Fill

Pressure Relief Valve A8436G

Vapor Internal Valves A3213A Internal Valve A3212R

Internal Valve A3212R

Internal Valve A3219FA600L or Flomatic® A7884FK

Adapters 5769H 5769K

Pump Globe Valve A7517AP

Globe Valve A7513AP A7517AP

Angle Valve A7704LP Cap 3184-90

Cap 3184-90 3194-90

Domestic Installation Check Lok 7590U 7591U

Multivalve G8475R Series

Multivalve 7556R Series

Filler Valve 6579 7579

Adapters 5767H Cap 3184-90 A3184-90

Adapters 5769K Cap 3194-90 A3194-90

First Stage Regulator LV4403SR/TR Series LV3403TR Pressure Relief Valve 7583G 8684G 8685G Second Stage Regulator LV4403B Series LV5503B Series

Pigtail 913PS12 912PS12

DOT Container

ine

dL

oun rgr

de

Un

ASME Container

Twin Stage Regulator LV404B4 Series LV404B9 Series LV404B23 Series LV404B29 Series

Service Valve 9101R Series 9101D Series

Pigtail 912JS12 913JS12 Pressure Relief Valve 8544 Series

Filler Valve 7647SC with cap

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

75


SECTION

2

Diagrams Bobtail Delivery Truck

Rotogage A9093TS A9094TS A9095TS

Pressure Relief Valve (2) A8434G CAUTION

Internal Valve A3217F Series or Flomatic速 A7883FK

Check Valve A3146

EG

O RO

T O G AU

G

Check Valve A3186

Check Valve A3176

Pump

R

E

Globe Valve A7513AP

Internal Valve A3209R050/80 A3209TL Globe Valve A7509BP Adapter 5765F Cap 3175P

Cap 3194-90 Angle Valve Adapter A7506AP 5769H Globe Valve A7509BP

Hose End Valve Excess Flow Valve Filling Connector 7574 A7797A Hydrostatic Relief Valve SS8021J

Emergency Shut Off Valves

76

Gas Equipment Catalog

victormfg.com


SECTION

2

Diagrams Bulk Storage Plant Capacity 18,000 to 30,000 Gallons

Internal Valves A3212R A3213A

Caps C5765N C5769N Adapters 3185 3195

R

Vapor ESV 7781AF

Angle Valve A7510BP

Angle Valve A7514AP

R

O R O T G A UG O

Liquid Line

EG

O R O T G A UG O

Rotogage A9095RS

Back Check Valves A3186

Shut-Off Valves A7513AP

Vapor Line

Pull Away Coupling A2141A16

EG

Rotogage A9095RS

E

Globe Valves A7509BP A7513AP

Internal Valves A3212R A3213A E

Angle Valve A7510BP

2

Multiport A8564 A8574

By Pass Valve

Globe Valve A7517AP To Railroad Cars

Liquid ESV 6016 Hydrostatic Relief Valves 3127U or SS8001U

Hydrostatic Globe Valves Relief Valves A7513AP 3127U or SS8001U

Pump Hydrostatic Relief Valves 3127U or SS8001U

Motor Fuel Applications

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

77

valves & accessories

Pull Away Coupling A2141A10

Relief Valves A3149MG


SECTION

2

Repair Kits Repair Kits Available by Part Number ECII part # 901 Series 903 Series A2141A6 Series A2141A8 Series A2141A10 A2141A16

Repair Kits Available 903-50 903-51 A2141A6-50 A2141A6M A2141A8-50 A2141A8M A2141A10-50 A2141A10M A2141A16-50 A2141A16M

A3209A Series

A3209A-50

A3210A Series

A3210A-50

A3212A Series A3213A Series A3217 Series

A3212A-K Kits A3212A-50 A3213A-K Kits A3213A-50 A3217F-50 A3217F-80 O-ring flange

A3217 Series A3217F-80G Gasket flange

A3219F-80 O-ring flange A3219F Series A3219F-80G Gasket flange

LV4403 Series 6532, 6533, 6542, 6543, Series Filler Valve

78

See Instruction Sheets 6542B-50 6542B-80

Gas Equipment Catalog

Contents Bonnet stem and seat disc assembly; large handwheel, self tapping screw Bonnet stem and seat disc assembly; small handwheel, self tapping screw O-Ring seal for female connector Male coupling O-Ring seal for female connector Male coupling O-Ring seal for female connector Male coupling O-Ring seal for female connector Male coupling Bearing; cam; gasket; main seat disc assembly; retaining ring, seal-o-ring; seat disc Bushing, gasket; jam ring; main seat disc assembly; upper and lower retaining rings; o-ring; seal rings(2); seat disc Excess flow spring; o-ring Bearing; cam; gasket; o-rings; seat disc; stem packing Excess flow spring; o-ring Bearing; cam; gasket; o-rings; seat disc; stem packing Dust seal; jam ring; stem o-ring; stem seals (3); stem spring; stem washer Cotter pin; dust seal; inner and outer stem bearing; jam ring; main and pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper and lower flange seal o-ring; wear button Dust seal; inner stem bearing; jam ring; lower flange seal gasket; main seat disc; outer stem bearing; pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper flange seal gasket; wear button Bumber; cotter pins (3); dirt seal; inner and outer stem bearing; lever release spring; main seat disc; poppet seat disc; pivot pin locknut; poppet bearing; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; upper and lower flange seal o-ring Bumber; cotter pins (3); dirt seal; inner stem bearing; lever release spring; lower flange seal gasket; main seat disc; poppet bearing; poppet seat disc; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; outer stem bearing; upper flange seal o-ring

Instruction Sheet # 903-300

WEBB# 163019 178960

A2141A-302

A2141A-303

A3209A-301

187018

A3210A-301

A3212-800

A3212A-300

A3213-800

A3213A-300

266446

A3217F-300

A3217F-302

A3217F-302G

A3219F-302

A3219F-302G

Gasket inlet nipple; seat disc assembly

2503-300N

Gaskets; spring; spring guide; stem and seat disc assembly; upper body Gaskets; spring; spring guide; stem and seat disc assembly

6542B-300

162513 162514

victormfg.com


SECTION

2

Repair Kits Repair Kits Available by Part Number (continued) ECII part # 6532, 6533, 6542, 6543, Series Service Valve

Repair Kits Available

7511A-20

Bonnet assembly

19104-50 19104-80 19105

6579 TA7034P TA7034LP 7141M 7177 7188 7193K-10B

7579-50 7579-80 TA7034-50 7141M-50 7177-50 7188-50 7193K-50 7193K-51

A7505AP A7506AP

A7505-50

A7505AP A7506AP

TA7034-50

A7507AP A7508AP

A7507-50

TA7507AP

TA7507-50

TA7509BP A7510BP

7505A-20

7507A-20

TA7509-50 7509B-20 A7509-50 7509B-20

Instruction Sheet #

WEBB#

19104-300

162536

19104-800

162537

19105-300

7579-300

186929

7579-300A

162523

TA7034-300

7141M-300 7177-300 7188-300

162505 186878 186881

A7505-300

TA7034-300

A7507-300

162517

163075

TA7507-300

TA7509-300

A7509-300

162518

TA7509B-300

187121

A7511-300

ta7509BP TA7510BP A7511AP A7511FP A7512AP A7512FP A7511AP A7511FP A7512AP A7512FP

TA7509B-50

TA7511A-50

Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer

TA7511-300

A7513AP A7514AP

A7513-50

A7513-300

162520

A7513AP A7514AP

A7513-20

A7513-300

A7513F-20

Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly

TA7513A-50

Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer

TA7513A-300

162521

TA7513AP TA7513FP TA7514AP TA7514FP

7513A-20

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

79

2 valves & accessories

A7511-50

Contents Complete MultiBonnet Assembly – bonnet assembly, hardwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Gaskets; seat disc and retainer assembly; spring; upper body Gaskets; seat disc and retainer assembly; spring Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Check assembly; gasket; o-ring; retaining ring Diaphragm; gasket; o-ring; seat disc; washer Hydraulic fluid; o-rings; piston; spring; trip latch 7193A-51 assembly; adjusting screw; nut; spring; tee Check body and disc assembly; gasket; nipple; tailpiece nipple; slip washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer


SECTION

2

Repair Kits Repair Kits Available by Part Number (continued) ECII part # A7515AP A7516AP A7517AP/FP A7518AP/FP TA7515AP TA7516AP A7517AP/FP A7518AP/FP 7547B Series 7547BX Series 7547SX Series 7547DX 7547FX 7547HX 7550P 7550UP 7551P A7550P A7550PX A7551P T553T Series

Repair Kits Available A7515-50

Contents Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer

A7515-B20

Bonnet assembly

TA7515A-50

Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer

WEBB#

A7515-300

162522

TA7515A-300

7547B-300

7547B-80

Gaskets; springs; seat disc and retainer assembly; upper body Gaskets; springs; seat disc and retainer assembly

7547B-300A

186909

7547B-80

Gaskets; springs; seat disc and retainer assembly

7547B-300A

7550-15

Bonnet assembly

A7550-15

Bonnet assembly

7553T-50

Bonnet; gasket; lever assembly; seat retainer assembly; stem Gasket; o-ring; seat disc Gaskets; o-ring; roll pin; seat disc; spring; stem assembly

7553T-300

7553T-301

A7553A-300

7547B-50

7553T-80

A7553A

A7553A-50

7554LV 7554LAV 7554SV 7554SAV

7554L-20

Bonnet assembly

7554S-20

Bonnet assembly

19104-300

162536

19104-800

162537

19105-300

162535

8475-300

162533

8475-81A

Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Body; gaskets; spring; stem and seat disc assembly Gaskets; spring, stem and seat disc assembly

8475-300A

162534

TA7513A-50

Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer

TA7513A-300

162521

7573A-300

7579-300

186929

7579-80

Gaskets; spring, seat disc retainer assembly Gaskets; seat disc and retainer assembly; spring; upper body Gaskets; seat disc and retainer assembly; spring

7579-300A

162523

7647B Series

7647B-80

Gaskets; seat disc and retainer assembly; spring

7647B-300

A7704 Series A7705 Series A7706 Series

A7705-50

Flange packing; friction washer; gaskets; seat disc

A7705-300

187046

A7707-50

Gaskets; groove pin; jam ring; o-ring; pressure seal rings; seat disc; washers Bonnet assembly; packing; seat disc and retainer; stem; washers

A7707-300

187047

7556VR, R Series Service Valve

19104-50 19104-80 19100-50B

7556vr, r Series Vapor Equalizing Valve TA7513AP TA7513FP TA7514AP TA7514FP 7573A Series 7579

A7707L A7708BL

80

Instruction Sheet #

8475-51A

7573A-81 7579-50

A7707-75

Gas Equipment Catalog

victormfg.com


SECTION

2

Repair Kits Repair Kits Available by Part Number (continued) ECII part # A7797 A7853A

Repair Kits Available A7797-50 A7797-75 A7853A-50

A7883FK A7883F-80 A7883F-150 A7883F-50 A7884FK A7884F-80 A7884-150 TA7894P

TA7894-50

7901 Series

7901T-50 7901T-80

A8016DP A8017 Series A8018DP A8017DH

A7797-300

162524

162525

A7853A-300

162526

7883-300

247073

7883-300

7883-300

189227

7883-300

247073

7883-300

372636

7883-300

TA7894-300

7901-300 7901-301

162529 —

Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer

A8016B-300

A8017BH-20R

Bonnet stem and seat disc assembly; gasket Upper body; gaskets; seat disc ad retainer assembly; spring Gasket; seal; seat disc and retainer assembly; spring Body; gaskets; spring; stem and seat disc assembly Gaskets, spring, stem and seat disc assembly Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw

A8017BH-300

8475-50

G8475RV G8475RW Vapor Equalizing Valve

8475-51A

8475-80

8475-81A 19104-50 19104-80 19100-50B

G8475RV G8475RW Fixed Liquid Level Gauge

3165C

Fixed liquid level gauge valve

8542G/AA8542 Series

8540-50

8547W/VWN

8547-2

Bleeder valve assemblies; packing; gland; set screw; washer; gasket; key Bonnet; o-ring and stem assembly Gaskets; spring; spring guide; stem and seat disc assembly; upper body Gaskets; spring; spring guide; stem and seat assembly

8555D/R Series Mfg’d 10/9 or before

WEBB#

A8016B-50

G8475RV G8475RW Filler Valve

G8475RV G8475RW Service Valve

Instruction Sheet #

6542B-50 6542B-80

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

8475-300F

162532 186967

8475-300

162533

8475-300A

162534

19104-300

162536

19104-800

162537

19100-300B

162535

8540-300

6542B-300

162513 162514

81

2 valves & accessories

A7883F-50

Contents Gaskets; groove pin; jam ring; o-ring; pressure seal rins; seat disc; washers Bonnet and lever asssembly; stem Block v-packing; gaskets; o-rings - piston, stem and yoke; roll pin; seat disc; seat disc retainer assembly; springs Bleeder assembly; bushing; cap; cap screws; filters; gaskets; lock washers; needle valve kit; orings; retaining ring; roll pin; screen filter; seal; set screws; springs; stem assembly kit; v-ring; x-seal Bushing; cylinder cap screws; filters, gaskets; insert; o-rings; retaining ring; seat disc; v-ring; x-seals Gaskets; seat disc; x-seal Bleeder assembly; bushing, cap; cap screws; filters; gaskets; lock washers; needle valve kit; o-rings; retaining ring; roll pin; screen filter; screw; seal; set screws; springs; stem assembly kit; v-ring; x-seal Bushing; cap screws; filters; gaskets; insert; o-rings; retaining ring; seat disc; v-ring; x-seal Gaskets; seat disc; x-seal Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly; gasket; lever Gasket; o-ring; seat retainer assembly


SECTION

2

Repair Kits Repair Kits Available by Part Number (continued) ECII part #

Repair Kits Available 8555-50

8555D/R Series Mfg’d 10/9 Filler Valve

8555-80

8555DL

19100-50B 19104-50

8555D Series Service Valve

19104-80 19100-50B

8555R Series Service Valve A/AA 8560 Series A/AA 8570 Series 8593A/AR Filler Valve 8593A/AR Vapor Equalizing Valve

19104-50 19104-80 8560-50 8475-50 8475-80 8475-51A 8475-81A 19104-50

8593A/AR Service Valve

19104-80 19100-50B 19104-50

9101C, D, H, R, P, Y Series Service Valve

19104-80 19100-50B 19101-50

9103C, D Series Service Valve

19104-50 19104-80 19100-50B

9103T9F 9106CO 9107K8A, K2A

19105-50 903-50 903-51 19100-50B 19104-50

9300Y/R

19104-80 19100-50B

82

Gas Equipment Catalog

Contents Gaskets; spring; spring guide; stem and seat disc assembly; upper body Gaskets; spring; spring guide; stem and seat disc assembly Bonnet; stem and o-ring assembly; hardwheel; self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bleeder valve assemblies; seat ring assemblies; pressure seal rings; packing gland; jam ring; washer; gasket Gaskets; seat disc and retainer assembly; spring; upper body Gasket; seal; seat disc and retainer assembly; spring Body; gaskets; spring; stem and seat disc assembly Gaskets; spring; stem and seat disc assembly Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Bonnet; stem and o-ring assembly; handwheel (small); self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Bonnet; stem and o-ring assembly; handwheel; self tapping screw Bonnet; stem and seat disc assembly; large handwheel; self tapping screw Bonnet; stem and seat disc assembly; small handwheel; self tapping screw Bonnet; stem and seat disc assembly; handwheel; self tapping screw Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw

Instruction Sheet # 8555-300

WEBB# 378312 378313

19100-300B

162535

19104-300

162536

19104-800

162537

19100-300B

162535

19104-300

162536

19104-800

162537

7564-300

8475-300F

162532 186967

8475-300

162533

8475-300A

162534

19104-300

162536

19104-800

162537

19100-300B

162535

19104-300

162536

19104-800

162537

19100-300B

162535

19101-300

19104-300

162536

19104-800

162537

19100-300B

162535

19105-300

903-300

163019 178960

19100-300B

162535

19104-300

162536

19104-800

162537

19100-300B

162535

victormfg.com


SECTION

2

Repair Kits Repair Kits Available for Obsolete Part Numbers ECII part # 1470 LV 1480V Series 1470W 1480W Series

1470, 1480 Series Service Valve 1470, 1480 Series Vapor Equalizing Valve AA1582E Series AA1584E Series AA1586E Series 2180 Series 2403 Series 2418 2418, 2550 Vapor Equalizing Valve 2465L, 2486 2503 Series 2250 2250 Vapor Equalizing Valve 2555 Series 2577 2577 Series

Contents

Instruction Sheet #

WEBB#

May be replaced with G8475RV Series

May be replaced with G8475W Series

2

3100-80A 3100-80B 3100-81K

Bonnet; Diaphragm assembly; stem Diaphragm assembly; washer Conversion kit; bonnet and stem assembly

3100K-300

162510 162511 162512

1475-80

Seat disc and stem assembly; spring; washer

1475-300F

2418-51

Body, gasket; seat disc and stem assembly; spring; washer

3100-301

AA1582E-300 AA1584E-300 AA158E-300 Replace with 8555D/R for cylinders with up to 200# propane capacity, for containers with capacities up to 400# use 6533A/R See Instruction Gasket; inlet nipple; seat disc assembly 2503-300N Sheet Replace with G8475RV Body, gasket; seat disc and stem assembly; 2418-51 — spring; washer No repair parts available - replace with G8475RV Series See Instruction Gasket; inlet nipple; seat disc assembly 2503-300N Sheet Replace with G8475RV Series Body, gasket; seat disc and stem assembly; 2418-51 — spring; washer Replace with 6532, 6533, 6542, 6543 Series No repair parts or replacement valve available Replace with 6532, 6533, 6542, 6543 Series AA1582E-50

Diaphragm and yoke assembly (standard); screen; small spring; stem and seat disc retainer assembly; tetraseals

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

— — — — — — — — — — — — — —

83

valves & accessories

1470, 1480 Series Service Valves

Repair Kits Available


SECTION

2

Repair Kits Repair Kits Available for Obsolete Part Numbers (continued) ECII part # 2580, 2581 2593, 2594 2593K, 2594K 2593/K, 2594/K Service Valve 2593/K, 2594/K Filler Valve 2593/K, 2594/K Vapor Equalizing Valve 3103

Repair Kits Available

Contents

No repair parts or replacement valve available – replace with 8555D/8555R Series Replace with 8593AR16.0 No replacement available 3100-80A Bonnet; Diaphragm assembly; stem 3100-301 3100-80B Diaphragm assembly; washer 3100-81K Conversion kit; bonnet and stem assembly 3100K-300 1475-80

Seat disc and stem assembly; spring; washer

Body; gasket; seat disc and stem assembly; spring; washer Replace with 9103 for cylinders 100 lbs. or less Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 6477A Vapor Equalizing Valve Gaskets; seat disc and retainer assembly; 5475-81A spring; stem Bonnet assembly; large handwheel; 903-50 6532D, 6533D, 6542D, self tapping screw 6543D Bonnet assembly; large handwheel; Service Valve 903-51 self tapping screw 6542B-50 Body, gasket; seat disc assembly; spring; stem 6532, 6533, 6542, 6543 Filler Valve 6542B-80 Gaskets; seat disc assembly; spring; stem Gaskets; jam ring, o-ring; pressure seal rings; A7016A A7505-50 seat disc; washer 7555 Replace with 8555D/R Series 7556 Mfg’s before 1962 8100-50 Bonnet assembly; handwheel A7762B, A7727B, Gaskets; flange packing; friction washer; AA1582F-50 A7728B seat disc Gaskets; seat disct and retainer assembly; 7747 Series 7547B-50 spring; upper body Bonnet; o-ring and stem assembly; handwheel; 8100 Series 8100-50 self tapping tee 8103 Series No repair kits available - replace with 9103 Series G8475 Mfg’d before 8100-50 Bonnet assembly; handwheel 1962 Body; gaskets; seat disc and retainer assembly; 8475-50 spring G8475 Filler Valves 8475-50 Gaskets; seat disc and retainer assembly; spring Body, gaskets; seat disc and retainer assembly; 8475-51A spring; stem G8475 Vapor Equalizing Valve Gaskets; seat disc and retainer assembly; 8475-81A spring; stem 8477 Replace with G8475RV 8477 Mfg’d before 1962 8100-50 Bonnet assembly; handwheel Service Valve

84

Instruction Sheet #

2418-51

Gas Equipment Catalog

WEBB# — — — 162510 162511 162512

1475-300F

— —

162533

162534

903-300

163019 178960

6542B-300

162513 162514

A7505-300

8100-300

— 162531

A7726B-300

7547B-300

8100-300

162531 —

8100-300 8475-300F

162531 162532 186967

8475-300

162533

8475-300A

162534 —

8100-300

162531

victormfg.com


SECTION

2

Repair Kits Repair Kits Available for Obsolete Part Numbers (continued) ECII part # 8477 Mfg’d before 1962 Vapor Equalizing Valve

Repair Kits Available 8475-51A 8475-81A

Contents Body; gaskets; seat disc and retainer assembly; spring; stem Gaskets; seat disc and retainer assembly; spring; stem

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

WEBB#

8475-300

162533

8475-300A

162534

8100-300

162531 —

19100-300B

162535

8475-300

162533

8475-300A

162534 —

903-300 6542B-300 8475-300F

163019 178960 162513 162514 162532 186967

8475-300

162533

8475-300A

162534 —

8100-300

162531

19100-300B

162535

8475-300F

162532 186967

8475-300

162533

8475-300A

162534

85

2 valves & accessories

8484 Mfg’d before 1962 8100-50 Bonnet assembly; handwheel Service Valve 8484A No replacement valves available 8484A 19100-50B Bonnet assembly; handwheel Service Valve Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 8484/A Vapor Equalizing Valve Gaskets; seat disc and retainer assembly; 8475-81A spring; stem 8555 Series Mfg’d No repair parts available – replace with 8555D/R Series before 1962 Bonnet assembly; large handwheel; 903-50 self tapping screw 8555S Series Service Valve Bonnet assembly; small handwheel; 903-51 self tapping screw 6542B-50 Body; gaskets; seat disc assembly; spring; stem 8555S Series Filler Valve 6542B-80 Gaskets; seat disc assembly; spring; stem Body; gasket; seat disc and retainer assembly; 8475-50 8593/K spring Filler Valve 8475-80 Gaskets; seat disc and retainer assembly; spring Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 8593/K Vapor Equilizing Valve Gaskets; seat disc and retainer assembly; 8475-81A spring; stem 8594 Replace with 8593AR16.0 8594/K Mfg’d before 8100-50 Bonnet assembly; handwheel 1962 Service Valve 8594/K Mfg’d before Bonnet and stem assembly; handwheel; 19100-50B 1962 Service Valve self tapping screw Body; gaskets; seat disc and retainer assembly; 8475-50 spring 8594/K 8475-80 Gaskets; seat disc and retainer assembly; spring Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 8594/K Gaskets; seat disc and retainer assembly; 8475-81A spring; stem

Instruction Sheet #


SECTION

3

Meters/Meter Accessories Single Joint Residential Gas Meter R-275, 275 SCFH

These class 250 residential meters are an improved revision of the R-200 family. The latest design concepts and modern engineering materials have been combined to provide a lighter weight, easier to handle, more durable meter which requires less maintenance and offers greater life expectancy. All models stocked are temperature compensated.

Specifications

Kits Available

capacity scfh 1/2” w.c. diff.

R275

MAX. APPROX. METER W.P. SHPG. CONNECTIONS But. prop. PSI WT. LBS AVAILABLE Webb#

MFR# R-275-20 Lt. R-275-30 Lt. R-415-30 Lt. S-275

150

175

5-10

14

225 150

260 175

10-125 5-10

21 14

20 Lt. 30 Lt. 30, 45 Lt. 3/4” NPT

244671 244675 244672 181926

with swivels, nuts & gaskets included. MFR#

Webb#

R-275-20LTK R-275-30LTK R-415-45LTK

181925 244642 181919

Natural Gas Capacities Meter Model

capacity rating at 1/2” w.c. differential

capacity rating at 2” w.c. differential

Webb#

750* 1000*

750 cfh 1000

1600 CFH 2200

181924 181911

* In Stock – Soon to be obsolete

Propane Gauge pressure (PSIG) 0.25 5 10

differential 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow

750 990 1340 1120 1630 1260 1920

1600 990 1340 1120 1630 1260 1920

1000 1360 1850 1540 2240 1740 2640

3000 1860 2520 2100 3060 2370 3600

5000 3100 4200 3500 5100 3950 6000

10000 6200 8400 7000 10200 7900 12000

Specifications

Meter Model 750 1000 3000 wo/flanges* 5000 wo/flanges* 10000 wo/flanges*

MAXIMUM WORKING PRESSURE (PSIG) 20 25 100 100 100

capacity rating at 1/2” w.c. differential of 0.6 Sp. Gr. gas cfh 750 1000 1450 2500 5000

capacity rating at 2” w.c. differential of 0.6 Sp. Gr. gas cfh 1600 2200 3000 5000 10000

STANDARD CONNECTIONS 45 Lt. 45 Lt. 3” - 8” PT 4” - 8” PT 4” - 8” PT

* Special Order

86

Gas Equipment Catalog

victormfg.com


SECTION

3

Meters/Meter Accessories Intermediate and Large Capacity Diaphragm Type Gas Meters (continued) Natural Gas Capacities SCFH of 0.6 Sp. Gr. Gas at Elevated Pressures Gauge Pressure (PSIG) 0.25 5 10

20 25 40 50 70 100

750 1600 1600 1840 2070 2080 2480 2320 2840 2480 3230

1600 1600 1600 1840 2070 2080 2480 2320 2840 2480 3230 2640 3570 3120 4450 3360 5000 3840 5960 4480 7170

1000 2200 2200 2530 2840 2860 3420 3190 3960 3410 4440 3630 4900

3000 3000 3000 3450 3880 3900 4660 4350 5400 4650 5820 4950 6700 5850 8700 6300 9370 7200 11200 8400 13400

5000 5000 5000 5750 6450 6500 7760 7250 9000 7750 10100 8250 11100 9750 13900 10500 15600 12000 18700 14000 22400

10000 10000 10000 11500 12900 13000 15550 14500 18000 15500 20200 16500 22300 19500 27800 21000 31200 24000 37400 28000 44800

Quick Reference Meter Capacity Chart MFR# R275/S275 R415 750 1000 1600 *

NAT GAS CAP 1/2” DIFF. 275,000 415,000 750,000 1,000,000 800,000

NAT GAS CAP 2” DIFF. — — 1,600,000 2,200,000 1,600,000

NAT GAS CAP 5 PSI — — 1,840,000 2,530,000 1,840,000

NAT GAS 10 PSI — 850,000 280,000 3,420,000 2,080,000

LP CAP

1/2” DIFF

435,000 647,000 1,866,000 2,488,000 1,866,000

LP CAP 2” DIFF. — — 2,463,120 3,383,680 263,120

LP CAP 5 PSI — — 2,786,560 3,831,520 2,786,560

LP CAP 10 PSI — — 3,134,880 4,329,120 3,134,880

(2 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.114 Correction Multiplier for 2 PSI at Sea Level (5 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.316 Correction Multiplier for 5 PSI at Sea Level (10 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.654 Correction Multiplier for 10 PSI at Sea Level * 100 PSI Max

To correct the actual cubic foot index reading to base (standard) conditions, the pressure multiplier is calculated by adding the line (gauge) pressure to the average atmospheric (psia) then dividing by the base pressure (psia). Eg: Pressure Multipler = (10 psig + 14.48 psia) ÷ 14.73 psia = 1.662

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

87

3 Meters/meter accessories

15

differential 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow


SECTION

3

Meters/Meter Accessories How to Identify Parts

Material Specifications Body/End Piece

Cast Iron Per ASTM A 126 Class B

Plug/Cap Stem

Cast Brass – ASTM B 584/Alloy 83600 or Alloy 84400

Brass Ball

CDA3600

Brass Nuts & Washers (Plug Valve)

ASTM B 584/Alloy B83600 or Alloy 84400 or MPIF Std. 35 CZ 3002

O-Rings/Torque Seals

Buna-N (Nitrile) or Neoprene Rubber

Port Seals (Ball Valve)

Neoprene Rubber

Union Tailpieces

Zinc plated yellow dichromate finished steel

Insulated Union Tailpieces

Zytel nylon insulation

Union Nut

Malleable Iron Per ASTM A 47 or Ductile Iron Per ASTM

Multiple Meter Manifold MFR# M080KPL070A M080KPL070C MSAFWWEB01

dESCription WEBB# 318128 11/4” Multiple Meter Manifold With Two 1” Outlets Spaced 12” On Center 318127 11/4” Multiple Meter Manifold With Three 1” Outlets Spaced 12” On Center 318552 Meter Manifold Complete 3/4” In 1” Out With Rego LV4403B66 Regulator, Coated Manifold, Meter Bar With 20 LT Swivels, 1” Dielectric Union 24±1/8 12±1/8

6±1/8

2±1/8

7/8±1/64 PORT

M080KPL070A

MSAFWWEB01

36±1/8 6±1/8

12±1/8

2±1/8

7/8±1/64 PORT

M080KPL070C

88

Gas Equipment Catalog

victormfg.com


SECTION

3

Meters/Meter Accessories

Cast Iron Meter Bars

Accessories

Horizontal Inlet and Outlet 6610 Series — 6” Centerline

6610-B

Meter Nuts — 30LT

Meter Nuts are used to connect straight and/or offset swivel gas fittings to the gas meter. Manufactured per ANSI B109.1.

Integral FIP

Meter Plugs — 20LT Meter Plugs are used to prevent the unintentional flow of gas from meter sets without meters attached. They also prevent insects and other foreign matter from entering the gas piping.

6610-F dESC. WEBB# 1” 250082

A 1

B 1

C 1

Gaskets are used to seal malleable iron offset or straight fittings on the face of the gas meter when tightening the swivel nut on meter thread of meter nut plug. These rubber gaskets made of Buna-N or neoprene are resistant to the action of natural and manufactured gases. The inside diameter is intended to lightly grip the pilot O.D. of the fitting to minimize problems during assembly of the swivel nut to the meter

Cast Iron Meter Bars With Integral Swivels Horizontal Inlet and Outlet 6620 Series — 6” Centerline

6620-B

Integral FIP

A 1

6620-F

B 1

C 20LT

MFR# EQU0016115402000 EQU0016115503000 EQU0016215502000 EQU0014116600000 EQU0014116707000 EQU0014116800000

dESCription WEBB# 20 LT Washer 244635 30 LT Washer 244638 45 LT Washer 244643 20 LT Black Nut 244636 30 LT Black Swivel Nut 244639 45 LT Black Nut 244644

Female insulated flat gasket union

Cast Iron Meter Bar

Steel Fabricated Accessories

Rear Center Horizontal Inlet and Vertical Outlet (Direct Center/Horizontal Inlet) 6722 Series — 6” Centerline

Brackets for Risers PRODUCT MFR# dESCription SUPPORT WEBB# BRKL-6 6” Wall Bracket Riser 252457 BRK9H 9” Wall Bracket Riser 253223 BRK38-01 14” Adjustable Wall Bracket Riser 192635

For multiple meter manifold applications.

6722-F

Gasket for Meter Swivels — 20LT & 30LT

Female insulated flat gasket union

MFR# dESC. WEBB# AYM6722-C-C Swivels 250083

A 1

B 1

C 20LT

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

89

Meters/meter accessories

MFR# AYM6610-F-1X1X1

3


SECTION

4

Cylinders, Tanks & Accessories Steel Cylinders

6.5 in./165.1 mm

Worthington’s steel portable cylinders in eight sizes for commercial, industrial, recreational and home applications. These cylinders are manufactured to Department of Transportation (DOT) 4BA-240 specifications.

9.125 in./ 231.8 mm

9.125 in./ 231.8 mm

4.25 lbs. to 60 lbs. LPG Cylinders

16.625 in./ 422.3 mm

11.625 in./ 295.3 mm

6.5 in./165.1 mm

4.25 lbs.

12.125 in./ 308 mm

12.125 in./ 308 mm

11 lbs.

17.625 in./ 447.6 mm

23.687 in./601.6 mm

6.5 in./165.1 mm

6.5 in./165.1 mm

20 lbs.

MFR# G/T4.5-OPD G/T11-OPD G/T20-OPD G/T30-OPD G/T40-OPD G/T43 G/T60

valve Type 1 With OPD Type 1 With OPD Type 1 With OPD Type 1 With OPD Type 1 With OPD POL Valve POL Valve

size 4.5 lbs. 11.0 lbs. 20 lbs. 30 lbs. 40 lbs. 43.5 lbs. 60 lbs.

MFR# G/T20H-OPD G/T30H-OPD G/T40H-OPD

Description 20# Horizontal Cylinders 30# Horizontal Cylinders 40# Horizontal Cylinders

webb# 194227 194228 190980 190983 194229 223351 185251 webb# 259991 259992 253750

12.125 in./ 308 mm

12.125 in./ 308 mm

30 lbs.

6.5 in./165.1 mm

40 lbs.

32.5 in./825.5 mm

29.250 in./743 mm

6.5 in./165.1 mm

G/T40H-OPD

G/T20H-OPD

12.25 in./ 311 mm

43.5 lbs.

6.5 in./165.1 mm

42.2 in./1071 mm

G/T30H-OPD Size LPG Capacity Water Capacity Tare Weight

60 lbs.

Collar Height Footring Dia. o/s

90

4.25 lbs. 1.0 gal. 3.8 liters 12.0 lbs. 5.4 kg. 11.9 lbs. 5.4 kg. 4.0 in. 101.6 mm 9.1 in. 231.2 mm

Gas Equipment Catalog

11 lbs. 2.6 gal. 9.8 liters 26.2 lbs. 11.9 kg. 13.8 lbs. 6.3 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm

20 lbs. 4.7 gal. 17.9 liters 47.6 lbs. 21.6 kg. 17.0 lbs. 7.7 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm

30 lbs. 7.1 gal. 26.8 liters 71.5 lbs. 32.4 kg. 25.4 lbs. 11.5 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm

40 lbs. 9.4 gal. 35.7 liters 95.2 lbs. 43.2 kg. 33.6 lbs. 15.2 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm

43.5 lbs. 10.3 gal. 38.8 liters 103.6 lbs. 47.0 kg. 34.4 lbs. 15.6 kg. 5.1 in. 129.5 mm 12.0 in. 304.8 mm

60 lbs. 14.2 gal. 53.5 liters 142.9 lbs. 64.8 kg. 48.0 lbs. 21.8 kg. 5.1 in. 130.2 mm 12.00 in. 304.8 mm

victormfg.com


SECTION

4

Cylinders, Tanks & Accessories Aluminum Cylinders 6 lbs. to 40 lbs. LPG Cylinders

Attractive, corrosion-resistant aluminum makes the ideal cylinder for home and recreational use. These cylinders are lightweight and easy to handle, but durable for the most demanding applications. The exterior finish is smooth and sleek. The interior is clean, dry and free of foreign matter. All aluminum cylinders meet DOT-4E specifications. MFR# G/TA6-OPD G/TA10-OPD G/TA20-OPD G/TA30-OPD G/TA40-OPD Size LPG Capacity

Tare Weight Collar Height

6 lbS. 1.4 gal. 5.4 liters 15.0 lbs. 6.8 kg. 8.0 lbs. 3.6 kg. 6.5 in. 165.1 mm

size 6 lbs. 10 lbs. 20 lbs. 30 lbs. 40 lbs.

webb# — — 185252 185253 254110

10 lbS. 2.4 gal. 9.8 liters 23.8 lbs. 10.8 kg. 10.1 lbs. 4.6 kg. 5.5 in. 139.7 mm

20 lbS. 4.7 gal. 17.9 liters 47.6 lbs. 21.6 kg. 14.1 lbs. 6.4 kg. 5.5 in. 139.7 mm

30 lbS. 7.1 gal. 26.8 liters 71.5 lbs. 32.4 kg. 18.0 lbs. 8.2 kg. 5.5 in. 139.7 mm

4

40 lbS. 9.4 gal. 35.7 liters 95.2 lbs. 43.2 kg. 20.9 lbs. 9.5 kg. 5.5 in. 139.7 mm

Steel Motor Fuel Cylinders

26.75 in./679.45 mm

33.5 lbs. Forklift Cylinders

Steel forklift cylinders feature two-piece construction with one horizontal weld for a stronger, better looking cylinder with less chance of leakage. The rugged, damage- resistant footring minimizes future repairs. Interior cylinder walls are smooth, dry and free of foreign matter. MFR# description G/T33MF No Filler Valve G/T33MFA 13/4 Filler Valve G/T43MFA 13/4 Filler Valve

size 331/2 lbs. 331/2 lbs. 431/2 lbs.

webb# 185239 185240 252696

Motor Fuel Cylinders

33.5 lbs.

Aluminum Motor Fuel Cylinders 12.5 in./317.5 mm

33.5 lbs. Forklift Cylinders

A: Universal float gauge B. Liquid service valve C. Safety relief valve D. Fixed liquid level E. Vapor service (plugged) F. Liquid fill port (plugged)

Worthington combines the highest standards of manufacturing quality with the light weight and durability of aluminum to provide you lift truck cylinders that readily return your investment through savings in handling, repairs, maintenance, and customer preference. Manufactured in accordance with DOT-4E240 specifications. MFR# DESCRIPTION size webb# — G/TA33MF Aluminum, No Filler Valve 331/2 lbs. G/TA33MFA Aluminum, 13/4 M. ACME Filler Valve 331/2 lbs. 185255

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

91

cylinders, Tanks & accessories

Water Capacity

valve Type 1 With OPD Type 1 With OPD Type1 With OPD Type1 With OPD Type1 With OPD


SECTION

4

Cylinders, Tanks & Accessories Composite Cylinder Pads mfr # description VCT420PAD Composite Pad for 420/200

webb# 433676

DOT/ASME LPG Cylinders 14.625 in./371.5 mm

100, 200, & 420 lbs. Cylinders

48.5 in./1232 mm

6.5 in./165.1 mm

• Exceptional quality and service. Manufactured to DOT, Transport Canada or ASME specifications. • All gas containment welds are automatic MIG/submerged arc welds. • All tanks are 100% leak tested before and after mechanical valve installation. • All tanks pretreated with chemical wash to improve corrosion resistance and powder coating adhesion. • Worthington’s manufacturing process minimizes odorant fade and maximizes paint coating quality. • Worthington’s Durabond 2000 powder paint finish is the highest quality and most durable powder coating available in the industry. • Tank interiors are clean, dry, and free of foreign matter. • Can be used in multiple cylinder installations. • Now with the industry’s largest diameter “user friendly” collar for more work room during filling. • On-time delivery and competitive pricing. Readily available during peak season to service new business.

100 lbs. A: Multi-Valve (3/4”) NPT B: NPT Float Gauge (!”) NPT

92

DOT Cylinders MFR# G/T100ASME G/T100ASME-G G/T100 G/T100M G/T100MW G/T200 G/T200G G/T100M G/T420 G/T420G

valve Tall 100# ASME Less Gauge 100# Squat With Gauge POL Service Multivalve Multivalve Multivalve Multivalve Multivalve Multivalve POL Multivalve POL

Gas Equipment Catalog

size 100 lbs. 100 lbs. 100 lbs. 100 lbs. 100 lbs. 200 lbs. 200 lbs. 200 lbs. 420 lbs. 420 lbs.

Color White White Gray Gray White White Gray Gray White Gray

webb# 263468 269529 185223 185226 194259 185229 192637 185226 185243 192638

victormfg.com


SECTION

4

Cylinders, Tanks & Accessories DOT/ASME LPG Cylinders

(continued)

G/T100ASME G/T100ASME-G

4

24 in./610 mm

39.7 in./1008 mm

ASME Cylinders MFR# G/T200ASME G/T200ASMEG G/T420ASME G/T420ASMEG

valve Multivalve Multivalve Multivalve POL Multivalve POL

size 200 lbs. 200 lbs. 420 lbs. 420 lbs.

Color webb# White 190984 Gray 193312 White 185244 Gray 193311

16 in./407 mm

Size LPG Capacity Water Capacity Tare Weight 30 in./762 mm

51.7 in./1313.2 mm

200 lbs.

Collar Height Footring Dia. o/s

100 lbS. 23.6 gal. 89.3 liters 239.0 lb. 108.4 kg. 71.0 lb. 32.2 kg. 5.1 in. 130.2 mm 14.5 in. 368.3 mm

200 lbS. 47.2 gal. 178.5 liters 474 lbs. 215.0 kg. 158.0 lb. 71.7 kg. 6.6 in. 167.6 mm 19.0 in. 482.6 mm

420 lbS. 99.1 gal. 374.9 liters 1000 lb. 453.6 kg. 272.0 lbs. 123.4 kg. 6.6 in. 167.6 mm 22.0 in. 558.8 mm

How to Order a Truckload 11 bundles make up a truckload. Special colors, or plastic mesh protective coatings are available upon request. There is a quantity of 9-420’s in a bundle, and 16-200’s in a bundle. You must specify DOT or ASME style tanks at time of order. Minimum order of 3 bundles is considered a partial truckload. No more than 3 different stops per truckload within a 150 mile radius.

420 lbs. Description and Size of 420# L.P.G. Cylinder Openings A: Safety Relief Valve (1”) NPT B: Fill Valve (3/4”) NPT C: NPT Float Gauge (1”) NPT D: Vapor Service Valve (3/4”) NPT

Open Collar 100# Cylinders mfr # PIGME350A

Description Multivalve

webb# 186562

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

93

cylinders, Tanks & accessories

16 in./407 mm


SECTION

4

Cylinders, Tanks & Accessories Underground/Aboveground Tanks

Underground Tanks MFR# G/T120UG G/T250UG G/T320UG G/T500UG G/T1000UG

capacity in w.g.

overall length

outside diameter (in)

overall height with 26” riser

weight

number per stack

number per load

webb#

120 250 320 500 1000

5’ - 8” 7’ - 8” 9’ - 6” 10’ - 0” 15’ - 10”

24” OD 30” OD 30” OD 37” OD 41” OD

32” 38” 38” 65” 69”

260 480 620 940 1800

12 5 5 5 5

96 30 25 25 15

265267 185234 185238 185249 185225

Aboveground Tanks MFR# G/T120AG G/T250AG G/T320AG G/T500AG G/T1000AG

capacity in w.g.

overall length

outside diameter (in)

LEG SPACING

weight (lbs)

number per stack

number per load

webb# (WHITE)

WEBB# (GREY)

120 250 320 500 1000

5’ - 7” 7’ - 8” 9’ - 6” 10’ - 0” 15’ - 10”

24” OD 30” OD 30” OD 37” OD 41” OD

371/2” 60” 60” 60” 138”

260 480 620 940 1800

14 9 9 6 5

112 54 45 30 15

205731 185233 185237 185248 185224

— 198025 — 198024 —

AG/UG Tank MFR# G/T120AG/UG G/T250AG/UG G/T320AG/UG G/T500AG/UG G/T1000AG/UG

capacity in w.g.

overall length

outside diameter (in)

overall height w/ riser

LEG SPACING

weight (LBS)

number per stack

number per load

webb#

120 250 320 500 1000

5’ - 8” 7’ - 9” 9’ - 11” 10’ - 0” 15’ - 10”

24” OD 30” OD 30” OD 37” OD 41” OD

36” 40” 40” 47” 51”

371/2” 60” 60” 60” 138”

260 480 620 940 1800

12 9 9 6 5

96 54 45 30 15

185228 202413 193388 194172 204553

500 Aboveground Tank with 11/4 Bottom Opening for Fill Stations MFR# G/T500AG-B

capacity in w.g.

overall length

outside diameter (in)

LEG SPACING

weight (LBS)

webb#

500

10’ - 0”

37” OD

60”

950

215818

All 1000 AG come standard with bottom 11/4 NPT opening.

Notes The chart for AG models is applicable to AG/UG and UG models with the following exceptions: 120 and 150 AG/UGs—stack drops from 14 to 12. 250 and 320 UGs—stack drops from 9 to 5 tanks. 475 and 500 UGs—stack drops from 6 to 5 tanks. • A full load must measure between 46’ and 50’. • We can ship 52’ (not allowed in some states) if the load meets additional criteria. (Must be all AG tanks)

94

Gas Equipment Catalog

victormfg.com


SECTION

4

Cylinders, Tanks & Accessories DOT vs. ASME DOT 240 psi Working Pressure 325 Test Pressure Re-Inspection After 12 Years Transportation Legal With Product

ASME 250 psi Working Pressure 375 Test Pressure No Current Re-Inspection Requirements No Transportation With More than 5% Product

DOT vs. ASME DOT Weld Repairable Heat Treated During Manufacture No Information Data Plate 70,000 Tensile

ASME Not Weld Repairable **Licensing Required Not Heat Treated During Manufacture Information Data Plate 75,000 Tensile

DOT vs. ASME Similar in that:

4

Remote Level Indicator mfr # description RBSRS-228 Remote Level Indicator

webb# 314605

Complete Remote Fuel Level and Temperature Monitoring System MFR#

Description

1000ag

1000ug

420

30K Bulk

WEBB#

REC-1

Controller; Modem Only

RECINT-1

Controller; Modem and Internet

x

x

x

x

432209

ITP-1

Solar Powered Transmitter

x

x

x

x

432205

SEN-1-24

Standard 24” Sensor Cable

x

SEN-1-24-RA

Right Angle 24” Sensor Cable for Underground Tank

ITP-1-STOR

Storage Tank Transmitter with Magnetic L Bracket.

x

432206

SEN-MAG-XX

Sensor for Magnetel Dial with up to 96” length. XX= length. 96” will locate the transmitter on the side of a 30,000 tank. Does not include dial.

x

432212

BATT-ITP-1

Battery Pack for Integrated Transmitter (ITP-1); Installation tool to activate a 6 second RF transmission rate.

CABLE

9V Contoller Cable; Installation tool to allow walkabout testing of receiver.

432204

PROG

Handheld Programmer

432207

432208

x

432210

x

Reusable. One required per installation

432211

432203

RSS has other accessories to suppport custom installations. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

95

cylinders, Tanks & accessories

Similar Wrapper Thickness Same Valves Save the Pressure Relief Same Strong Wide Collar Same Strong Footring Same Liftlugs Same Valve Configurations on 420’s All Vacuum Purged


SECTION

4

Cylinders, Tanks & Accessories “Wall Hugger” Cylinder Vise Big Performance, Small Profile

The unique design of this powerful cylinder vise allows you to replace cylinder valves quickly and easily, yet does not require a lot of valuable dock space. The “Wall Hugger” actually uses less floor space than this catalog! MFR# description AMDCV-1 Cylinder Vise

webb# 202780

Pump Station Enclosure Protect Your Equipment

• Double doors, Heavy duty load bearing floor. • Adjustable top shelf. • “Duty to Warn” decals. • Tamper resistant hardware.

“Wall Hugger” Cylinder Vise

MFR# description PS302LD 68” X 44” X 30” PS303LD 68” X 44” X 39”

webb# — 184880

Pump Station Enclosure

“Little Giant” Stationary Tank Inverter Will lift and invert all cylinders from a single (or double) 100# thru a full 420#. Indexes to 90°, 180° or 45° to facilitate valve relacement, evacuation and bottom maintenance. Doubles as a vice. Small 3’ X 4’ base saves dock space. MFR# description AMDLG Tank Inverter

“Little Giant” Tank Inverter

webb# 184881

20 Pound Cylinder Cabinets MFR# description AMDLB06302SS 6 Capacity AMDLB12302MS 12 Capacity, 3 Wide

webb# 202790 202792

Fork Lift Cabinets MFR# description AMDFH12302LS 12 Capacity, 3 Wide, Horizontal AMDFV06302MS 12 Capacity, 3 Wide, Vertical AMDFH16402LD 16 Capacity, 4 Wide, Horizontal

webb# 202791 202793 202794

Portable Beam Utility Scale Model 1124

42.5” Tall

Applications A general purpose, 1000 lbs., portable scale utilizing a mechanical beam for industrial and commercial use. mFR# description FBS1124 Portable Beam Scale

webb# 181957

Features & Benefits • 1000 lbs. capacity. • 17.75” X 23.5” platform. • Rugged, cast iron base, lever system and platform are designed for durability. • Easy to read, brass beam insert will not fade in direct sunlight. • Easy to maneuver with built-in wheels. • Conforms to NTEP standards for weighing food, commodities, propane and more.

96

Gas Equipment Catalog

victormfg.com


SECTION

4

Cylinders, Tanks & Accessories

OPD Cylinder Vise Wrench Kit

Cylinder Hand Trucks

The Best Way to Install OPD Cylinder Valves The TTW-3 is a totally new concept in valve wrenches. It quickens installation and removal of QC cylinder valves from DOT containers. The wrench works on all Style 1 (QC) valves, particularly the fixed handwheel OPD’s that are mandated by the DOT for all 5 lbs. to 40 lbs. cylinders. The TTW-3 mates to the cylinder valve QC thread, rather than the POL thread, reducing the possibility of valve deformation when removing or installing. The wrench seats flush against the valve face, distributing torque across a wider area. And the compact TTW-3 fits under the handwheel valve and allows rotation inside the cylinder collar, simplifying the removal and installation procedure.

MFR# VCTTTW-3

Cylinder Hand Truck

Appliance Truck MFR# HPREA6061

4

webb# 182215

webb# 192938 Appliance Truck

Methanol Injector mfr # description VCTTMI-1QL Methanol Injector

webb# 215392

POL Valve Wrench Kit Handle

TMI-1QL Methanol Injector

Hand Held Pump Style

Wrench

mfr# description RIMABJ2 Methanol Injector Hand Held Pump Style

webb# 186594

POL Adapter

MFR# description VCT201 Polished POL Plugs VCT202 Valve Wrench VCT203 Handle 20-3

webb# 184417 184418 184419

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

97

cylinders, Tanks & accessories

The TTW-3 also incorporates a bleed orifice safety feature that will indicate any pressure remaining in the cylinder before removing the valve by simply opening the valve slightly prior to loosening. The wrench is made from tough, durable alloy and forged steel components. This long-lasting construction resists corrosion and distortion.

MFR# description webb# HPR70416 For LP Cylinders 182214 VCTNMP79004P For 420 lbs. Cylinders 190693


SECTION

4

Cylinders, Tanks & Accessories Magnesium Anodes

Pipe Wrap

Magnesium anodes have a 10’ length of #12 electric wire attached. MFR# description

MFR# description

webb#

Anode 17

#17

183403

Anode 5

#5

215998

Typical Tank Anode Requirements

Iron Pipe Anode Requirements

17 lbS. Anodes tank size required 500 gals. 1 1,000 gals. 2 3,000 gals. 4 400 to 5,000 gals. 6 10,000 gals. 8 15,000 gals. 10 20,000 gals. 12 25,000 to 30,000 gals. 14

webb# 243386

KMC4130

Yellow Pipe Wrap, 2” X 100’

PAS9052R

Black Pipe Wrap, 2” X 100’

MISUD21

Underground Gas Detector Tape

183516

VCTTRACER

Tracer Wire 500’ – 14GA

359306

ELE1207PE30-4E Tracer Wire 500’ – 12GA

243218

81161

Typical Small ASME Container Underground Installation

Pipe Pipe size length Install 0ne 5 lbs. Anode 3/4” 500’ 11/4” 450’ 11/2” 425’ 2” 400’ Install 0ne 17 lbs. Anode 3” 700’ 14” 500’ 6” 400’ 8” 350’

Conversion Factors Factors

lbs

1 CU Yard of Concrete

4000

CU ft. of Concrete

148

CU ft. of Water

62.4

1 Gal. of Water

8.345

1 CU Yard of Sand

2400

1 CU Yard of Dirt (Clean Humus or Fill)

3800

500 gal. of water X 8.345 (pounds per gallon) = 4172.5 lbs. of water – tank weight (940#) = 3232.5 pounds of buoyancy to overcome. Pad length and width must be converted to feet in the chart below to have the calculator formula’s to work correctly. Good engineering practice would be to make the pad at least 1 ft. (6 inches on each side) bigger than the container so the stainless anchors only have a direct vertical pull when attached to the stainless coated cable. 3/8” coated cable should provide enough tensile strength to overcome the bouyancy factor.

Tank Buoyancy Chart for Concrete Pad Size quality steel tank size

pad length (min)

Pad width (min)

Weight of tank

tank h20 capacity

buoyancy factor needed to keep in ground

4” pad

6” pad

9” pad

12” pad

120 U/G (5’ 8” L X 24” OD)

5.583

3

260

120

741.4

818.0212

1239.426

1859.139

2478.852

250 U/G (7’ 8” L X 30” OD)

7.666

3.5

480

250

1606.25

1310.426

1985.494

2978.241

3970.988

320 U/G (9’ 6” L X 30” OD)

9.5

3.5

620

320

2050.4

1623.93

2460.5

3690.75

4921

500 U/G (10’ 0” L X 37” OD)

10

4.08

940

500

3232.5

1992.672

3019.2

4528.8

6038.4

1000 U/G (15’ 10” L X 41” OD)

15.833

4.417

1800

1000

6545

3415.594

5175.143

7762.714

10350.29

This calculator is for general reference only. When in doubt have an engineer design a system to your individual job specification and local code requirements.

98

Gas Equipment Catalog

victormfg.com


SECTION

4

Cylinders, Tanks & Accessories

Propane Storage Vessels The withdrawal of propane vapor from a vessel lowers the contained pressure. This causes the liquid to “boil” in an effort to restore the pressure by generating vapor to replace that which was withdrawn. The required “latent heat of vaporization” is surrendered by the liquid and causes the temperature of the liquid to drop as a result of the heat so expended.

Simple formulae for determining the proper number of DOT cylinders and proper size of ASME storage containers for various loads where temperatures may reach 0°F will be found in the sections on 100# DOT Cylinders and ASME Storage tanks respectively

Determining Total Load In order to properly size the storage container, regulator and piping, the total BTU load must be determined. The total load is the sum of all gas usage in the installation. It is arrived at by adding up the BTU input of all appliances in the installation. The BTU input may be obtained from the nameplate on the appliance or from the manufacturers literature. Future appliances which may be installed should also be considered when planning the initial installation to eliminate the need for a later revision of the piping and storage facilities. Where it may be more desirable to have ratings expressed in CFH, divide the total BTU load by 2516 for CFH of propane.

Appliance Range, Free Standing, Domestic Built-in Oven or Broiler, Domestic Built-in Top Unit, Domestic

Approx Input (BTU per Hour) 65,000 25,000 40,000

Water Heater, Quick Recovery, Automatic Storage 30 Gallon Tank 40 Gallon Tank 50 Gallon tank Water Heater, Automatic Instantaneous 2 gal./min. 4 gal./min. 6 gal./min. Refrigerator Clothes Dryer, Domestic Incinerator, Domestic

30,000 38,000 50,000 142,800 285,000 482,000 3,000 20,000 32,000

4

100# DOT Cylinders

“Rule of Thumb” Guide for Installing 100 lb. Cylinders For continuous draws where temperatures may reach zero F. Assume the vaporization rate of a 100 lb. cylinder as approximately 50,000 BTU per hour. Number of Cylinders per side = Total load in BTU’s 50,000 Example: Assume total load = 200,000 BTU/hr. Cylinders per side = 200,000 = 4 cylinders per side. 50,000

Vaporization Rate 100 lbs. Propane Cylinders (approximate) Lbs. of Propane in Cyl. 100 90 80 70 60 50 40 30 20 10

Maximum Continuous Draw in BTU Per Hour at Various Temperatures in Degrees F. 0 113,000 104,000 94,000 83,000 75,000 64,000 55,000 45,000 36,000 28,000

20 167,000 152,000 137,000 122,000 109,000 94,000 79,000 66,000 51,000 38,000

40 214,000 200,000 180,000 160,000 140,000 125,000 105,000 85,000 68,000 49,000

60 277,000 247,000 214,000 199,000 176,000 154,000 131,000 107,000 83,000 60,000

70 300,000 277,000 236,000 214,000 192,000 167,000 141,000 118,000 92,000 66,000

This chart shows the vaporization rate of containers in terms of the temperature of the liquid and the wet surface area of the container. When the temperature is lower or if the container has less liquid in it, the vaporization rate of the container is a lower value. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

99

cylinders, Tanks & accessories

The heat lost due to the vaporization of the liquid is replaced by the heat in the air surrounding the container. This heat is transferred from the air through the metal surface of the vessel into the liquid. The area of the vessel in contact with vapor is not considered because the heat absorbed by the vapor is negligible. The surface area of the vessel that is bathed in liquid is known as the “wetted surface”. The greater this wetted surface, or in other words the greater the amount of liquid in the vessel, the greater the vaporization capacity of the system. A larger container would have a larger wetted surface area and therefore would have greater vaporization capacity. If the liquid in the vessel receives heat for vaporization from the outside air, the higher the outside air temperature, the higher the vaporization rate of the system. How all this affects the vaporization rate of a 100 lbs. cylinder is shown in a following section (return to contents and see 100# DOT cylinders. You will note that the worst conditions for vaporization rates are when the container has a small amount of liquid in it and the outside air temperature is low.

Approximate BTU Input for Some Common Appliances


SECTION

4

Cylinders, Tanks & Accessories ASME Storage Containers

Determining Propane Vaporization Capacity “Rule of Thumb” Guide for ASME LP-Gas Storage Containers Where D = Outside diameter in inches L = Overall length in inches K = Constant for percent of volume of liquid in container L D

percentage of container filled

k equals

propane vaporization capacity at 00 F (in Btu.hr.)*

60 50 40 30 20 10

100 90 80 70 60 45

D X L X 100 D X L X 90 D X L X 80 D X L X 70 D X L X 60 D X L X 45

* These formulae allow for the temperature of the liquid to refrigerate to -20°F (below zero), producing a temperature differential of 20°F for the transfer of heat from the air to the container’s “wetted” surface and then into the liquid. The vapor space area of the vessel is not considered. Its effect is negligible.

Vaporizing Capacities for Other Air Temperatures Multiply the results obtained with the above formulae by one of the following factors for the prevailing temperature.

100

prevailing air temperature (in degrees f)

-15 -10 -5 0

Gas Equipment Catalog

multiplier

prevailing air temperature (in degrees f)

multiplier

0.25 0.50 0.75 1.00

+5 +10 +15 +20

1.25 1.50 1.75 2.00

victormfg.com


SECTION

4

Cylinders, Tanks & Accessories Quality Steel Replacement Parts

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

ALT. WEBB # 315792

315792

4 cylinders, Tanks & accessories

QS PART # DESCRIPTION MFR # WEBB # ALT. MFR # Tank Size 120 01-001 Filler Valve 7579-T 162745 01-009-1 Float Gauge B8981-1186 HA-130AQ 01-021 Multi Valve, Tube length 6.7 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-031 U/G Float Gauge JB-302 315650 Tank Size 150 01-001 Filler Valve 7579-T 162745 01-009-1 Float Gauge B8981-1186 HA-130AQ 01-021 Multi Valve, Tube length 6.7 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-008-1 Check Lok 7590-UT 162748 01-031 U/G Float Gauge JB-302 315650 Tank Size 250 01-001 Filler Valve 7579-T 162745 01-010-1 Float Gauge HA 156-AQ 315681 01-023 Multi Valve, Tube length 8.5 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-008-1 Check Lok 7590-UT 162748 01-017 U/G Float Gauge, L.N.R. JB350B 315667 JB332BRN 01-045 U/G Float Gauge, S.N.R. JB224B Tank Size 320 01-001 Filler Valve 7579-T 162745 01-010-1 Float Gauge HA 156-AQ 315679 01-023 Multi Valve, Tube length 8.5 7556-RS 162742 01-007 Relief Valve 7583-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-017 U/G Float Gauge, L.N.R. JB350B 315661 JB332BRN 01-045 U/G Float Gauge, S.N.R. JB224B Tank Size 475 01-001 Filler Valve 7579-T 162745 01-011-1 Float Gauge HA 194-AQRN 315679 01-002 Multi Valve, Tube length 10.5 7556-RS 162742 01-012 Relief Valve 8684-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 01-046 U/G Float Gauge, S.N.R. JB260C Tank Size 500 01-001 Filler Valve 7579-T 162745 01-011-1 Float Gauge HA 194-AQ 315679 01-002 Multi Valve, Tube length 10.5 7556-RS 162742 01-012 Relief Valve 8684-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 01-046 U/G Float Gauge, S.N.R. JB260C Tank Size 1000 01-001 Filler Valve 7579-T 162745 01-016-1 Float Gauge HA 210-AQ 315793 HA210ARN 01-025 Multi Valve, Tube length 11.3 7556-RS 162742 01-013 Relief Valve 8685-GT 162750 01-008-1 Check Lok 7590-UT 162748 01-019 U/G Float Gauge, L.N.R. JB404B 315657 JB386ERN 01-047 U/G Float Gauge, S.N.R. JB280C

315807

315807

315806

315806

315677

315805

101


SECTION

5

Paint & Supplies Premium Industrial Coatings Primers

A single package epoxy primer of high quality that offers excellent corrosion resistance and fast re-coat time. This product is user friendly and offers great coverage. MFR# SUM855G1368 SUM899W1370

description Gray-Green Primer Off White Primer

webb# 184237 184238

Foot Ring Protector Primers

A protective coating that is modified with phenolic resins making this a great product for the bottoms of cylinders. When applied properly, this product aids in corrosion resistance. Can be mopped, brushed or sprayed. MFR#

description

SUM880N2209

Foot Ring Protector, Black

webb# 184248

White Paint Foot Ring Protector

White Paint

Blued White Tank enamel was formulated especially for Propane Tanks offering elasticity, excellent weathering, one coat coverage, and user friendly. Works great with rollers, brushing and also can be sprayed. Silicone Alkyd White is the premium of our Tank Enamels, modified with high percentage of silicone offering excellent gloss and color retention. This product is highly recommended for painting storage tanks when maximized coating life is a must. MFR#

description

SUM880W2203

No. 5 Blued White Tank Enamel

webb# 184244

SUM880W2201

No. 7 Silicone Alkyd White

184249

Aluminum Paint Tank Coating is our most popular aluminum finish that has nearly 2 pounds of aluminum paste in every gallon. SC1000 was formulated using premium blend of oleoresinous varnishes. Strontium Chromate is the premium in our aluminum finishes, all the same great qualities of our SC1000 plus the addition of built in rust inhibitor.

Aluminum Paint

MFR#

description

webb#

SUM880S2205

SC1000 Tank Coating, Aluminum

184233

SUM880S2206

SC1110 Strontium Chromate, Aluminum

184234

SUM880S2207

Aluminum Enamel Paint

184235

Enviro-Tuff Industrial Enamels A high quality industrial enamel offered in an assortment of colors to personalize your tanks. This product is great for many other exterior uses.

Enviro-Tuff Industrial Enamels

MFR#

description

webb#

SUM880G0166

Green Enamel

184182

SUM880L0184

Tan Enamel

184239

SUM885N2100

Black Enamel

184240

SUM880D0130

Mist Gray

184236

SUM885R2108

Red

184241

SUM886Y8625

Industrial Yellow

184245

Paint Thinner

102

MFR#

description

SUM856X2210

XL Thinner

Gas Equipment Catalog

webb# 184251

victormfg.com


SECTION

5

Paint & Supplies Premium Industrial Coatings

(continued)

Coverage Data: Enamels and Primers Tank size (Gallons)

Approx sq. feet

No. 5 blued white

no. 7 sillicone alkyd white

100d8431 hi solids

uni-pox primer 1370 off white

uni-pox primer 1368 gray green

30,000 18,000 12,000 1,000 500 250 Sq. Ft. Coverage per Gal. at 1 dry mil Recommended dft. per coat

1,950 1,250 1,150 225 115 55

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

740

760

810

785

785

1.5 - 2.5 mils 295 - 495 Sq. Ft.

1.5 - 2.5 mils 305 - 505 Sq. Ft.

1.5 - 2.5 mils 325 - 540 Sq. Ft.

1.5 - 2.5 mils 315 - 520 Sq. Ft.

1.5 - 2.5 mils 315 - 520 Sq. Ft.

The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.

Coverage Data: Aluminums and Primers Approx sq. feet

sc 100 aluminum tank covering

sc 1110 strontium chromate

sc 2000 non-glare aluminum

high solids universal primer

epoxy ester primer 1370 off white

30,000 18,000 12,000 1,000 500 250 Sq. Ft. Coverage per Gal. at 1 dry mil Recommended dft. per coat

1,950 1,250 1,150 225 115 55

8 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

8 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

8 Gallons 6 Gallons 5 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon

635

665

740

810

615

1.5 - 2.5 mils 255 - 425 Sq. Ft.

1.5 - 2.5 mils 265 - 445 Sq. Ft.

1.5 - 2.5 mils 295 - 495 Sq. Ft.

1.5 - 2.5 mils 325 - 540 Sq. Ft.

1.5 - 2.5 mils 250 - 415 Sq. Ft.

The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.

Paint Accessories MFR# SUMSC-TTB002 SUMKM-1009 SUMSC-BC003 SUMSC-BG-001 SUMSCL9V14 SUMSC-CR006 SUMSC-TR09K SUMSC-EP03P SUMSC-WB042 SUMSC-CR063

description 12” Trim Brush 5 Gal. Bucket Bucket Cover (3 Per Pkg.) Bucket Grid 9” Lambswool Roller Cover Contour Roller Cover 9” Roller Handle 42” Extension – 3 pc. Pole Wire Brush Contour Roller Complete

webb# 184250 192127 192913 242094 184195 184192 184247 242095 — 264998

Contour Roller Complete Bucket Grid

Wire Brush

12” Trim Brush

Roller Handle

42” Extension

Bucket Cover

Lambswool Roller Cover

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

5 Gallon Bucket

103

5 paint & supplies

Tank size (Gallons)


SECTION

5

Signs/Decals Signs & Decals

Reflective Warning Scotchlite Decals MFR# S22-A S22-B S22-C S29

Updated Test & Retest Kits

description size Railroad Crossing 8” X 36” Railroad Crossing 4” X 36” Railroad Crossing 8” X 12” Railroad Crossing 4” X 36”

webb# — 181431 309162 —

MFR# V31 V32

description size Periodic Inspection Chart 6” X 18” 5 Year Inspection Kit 6” X 18”

webb# — 359351

S22-A S22-B

S22-C

V31

S29

Fuel Signs

Unless otherwise indicated, the items following are red letters on white background. M = Metal (Aluminum) A = 6” letters S = Scotchlite® Brand Reflective B = 4” letters V = Vinyl BB = 3” letters P = Polyethylene (plastic) C = 2” letters D = 1” letters MFR# V72 V288-BB V58 P101 V62 V47

No Smoking Sign

description size webb# Safety First (Blue Only) — — Propane Gas — 192754 LPG (Black On Orange) 21/2” X 3” — Capacity Chart (Red/Blue On Poly) — 260991 Sheet of 10 2# Labels (Black On Yellow) 4” X 51/2” 309285 Propane 9” X 38” 372646

MFR# V49

description size No Smoking Vinyl (Stick-On Decal) 10” X 42”

Placard Holder MFR# MPH69

V32 webb# 188815

V49

description .050 Aluminum With Baked Enamel Finish & Stainless Steel Clip

webb# 181423

V288-BB

CYLINDER FILLING CAPACITY CHART W.C.

LBS. PROPANE

W.C.

LBS. PROPANE

2.39

1

35.8

1

4.78

2

38.2

2

7.17

3

40.6

3

9.56

4

43.0

4

11.9

5

45.4

5

14.3

6

47.8

6

16.7

7

59.7

7

19.1

8

71.7

8

21.5

9

78.8

9

23.9

10

83.6

10

26.2

11

95.6

11

28.6

12

105.1

12

31.0

13

119.5

13

33.4

14

239

14

P101

V47

104

MPH69

D.O.T. Placarding for Bulk Transporters

V58 V72 PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE

GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

2 2 2 2 2 2 2 2 2 2

P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I.

MFR# V1075 P1075 G1075

description Vinyl Polyethylene Magnetic Blanket

webb# 181435 181426 181418

V1075 P1075 G1075

V62

Gas Equipment Catalog

victormfg.com


SECTION

5

Signs/Decals

Signs and Decals (continued) OPD Signs

Storage Tank Diamond for Propane Red, Yellow, Blue & Black on White Vinyl MFR# V704-3 V704-1

description size 300’ Legibility 15” X 15” 100’ Legibility 7.5” X 7.5”

webb# 308184 269724

MFR# P114 P111

description size Retrofit Chart (Blue On White Poly) 18” X 24” Alert Sign (4 Holes & 2 Colors) 16” X 20”

webb# 359348 251721

V704-3 V704-1

Danger Sign MFR# SP53-R

description size Black On Yellow Vinyl 4” X 9”

webb# 181434

P111 P114

Liquid/Vapor Signs

description size Vinyl 11” X 12” Polyethylene 11” X 12” Vinyl 11” X 12” Polyethylene 11” X 12” Black on Yellow Vinyl 2” X 31/2”

webb# 192753 269726 309161 269725 —

V90-5

V91-5

Emergency Signs MFR# V81 P81 V82 P82 11-V-127 11-P-127

V121/P121

webb# — 309284 269723

V90

Filling Procedure Decals MFR# V121 P121 V122 P122 V79

description size Red On White Vinyl 1” X 4” Red On White Vinyl (5 per Sheet) 1” X 4” Red On White Vinyl (5 per Sheet) 1” X 4”

description size Pull – Red On White Vinyl 10” X 12” Pull – Red On White Polyethylene 10” X 12” Push – Red On White Vinyl 10” X 12” Push – Red On White Polyethylene 10” X 12” Red On White Vinyl 12” X 30” Red On White Polyethylene 12” X 30”

webb# — 359350 — 192752 — —

V122/P122 V81/ P81

V82/ P82 11-V-127 11-P-127

V79

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

105

5 paint & supplies

MFR# V90 V90-5 V91-5


SECTION

5

Signs/Decals Signs and Decals (continued) Propane Filling Station Signs

Portable Cylinder Labels MFR# A16 AA16 A53

description size Curved, Black Imprint — Not Curved — Black on White Vinyl 1.5” X 5”

webb# 181416 181417 223683

MFR# M97A M97-AX M97-AD M97-AXD V14 C37 M97-FR

description size webb# Single Faced (Blue On White Aluminum) 2’ X 4’ 181421 Exchange (Blue On White Aluminum) 2’ X 4’ — Double Faced (Blue On White Aluminum) 2’ X 4’ 181413 Exchange (Blue On White Aluminum) 2’ X 4’ — Red & Black On White Vinyl 12” X 16” 309160 Red & Black On Coroplast 12” X 24” — Frame for 2’ X 4’ Signs With Hardware — 181444

A16 (Curved)

AA16

A53

M97A, M97AD

M97AX, M97AXD

Hazard Sign MFR# HZ116

description size Blue, Yellow, Red & Black 21/2” X 5”

webb# 181419

V14

No Smoking While Refueling Decals MFR# V266 V26-A V26-B M26-C

description size Red On White Vinyl 24” X 36” Red On White Vinyl 12” X 18” Red On White Vinyl 12” X 18” Baked Enamel On Aluminum 24” X 36”

C37 webb# — 309159 — 181441

MFR# description MISSIGNDV Direct Vent Appliance Below

VersaPrinter™

webb# 309803

Label Maker

Quickly create any type of label or sign and print as many as you need in a matter of minutes. . . right from your own computer! MFR# B/S42001

106

Gas Equipment Catalog

description Portable Label Pusher

webb# 193975

victormfg.com


SECTION

6

Gauges The “One” Gauge™ Adjustable Liquid-Level Gauge 49S

Application The “One” Gauge™ is a magnetically-coupled liquid-level gauge that adjusts in length and accepts a variety of float stem lengths. This feature makes it easy to quickly and economically replace non-functional gauges in the field for a large variety of tank sizes. They are UL listed. General Information & Features This gauge features a range of adjustable stems which, when mated with an appropriatelength float assembly, enables LP Gas dealers to easily replace the liquid-level gauge in virtually all LP Gas tanks used for domestic storage or mobile applications. Models are available with Junior™ bolted heads in aluminum or brass, Senior™ bolted heads in aluminum, and a version with a Junior™ 11/4” or 1” male NPTF brass head. The design utilizes a square-brass centershaft telescoping inside a square-aluminum pinionshaft, both of which are housed in telescoping aluminum support tubes. An aluminum locknut compresses an aluminum locking sleeve to secure the tubes at the required stem length. All other components are of the same materials as standard Rochester LP Gas gauges. The proper float assembly is attached to the gear housing on the adjustable stem per instructions shown below. Gear Housing Zinc Approvals Gauges are UL listed for LP Gas Service Applications

6 gauges

Materials of Construction Head Aluminum or Brass Drive Magnet Alnico Centershaft Brass Pinionshaft & Support Tubes Aluminum Gears, Cross Stud, & Bearings Stainless Steel

When ordering, specify: 1. Gauge head size ( Jr., Sr., 11/4” NPTF, or 1” NPTF). 2. Aluminum or brass. 3. Tank diameter, shown on nameplate. 4. Mounting location (top, side, end, or angle). 5. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline, or the distance in inches above or below the horizontal centerline to the center of the gauge opening. 6. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellisoidal). 7. Specify the “H” dimension. This is the distance in inches from the surface of the tank to the top of the mounting surface.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

107


SECTION

6

Gauges Adjustable LP Gas Gauges Jr. Adjustable Gauges—Less Float MFR# 0049s02159bp 0049s02170bp

Description

Webb#

dial

Webb#

359139 361810

5909S02733 5909S02733

184077 184077

Webb#

dial

Webb#

359136 —

5986S02733 5986S02733

184073 184073

Description

Webb#

dial

Webb#

1” - 121/2” to 193/4” Brass Head 1” - 191/2” to 331/4” Brass Head

359137 362437

5909S02733 5909S02733

184077 184077

Jr. 121/2” to 193/4” Brass Head Jr. 191/2” to 331/4” Brass Head

Sr. Adjustable Gauges—Less Float MFR# 0049s02207p 0049s02208p

Description Sr. 121/2” to 193/4” Alum. Head Sr. 191/2” to 331/4” Alum. Head

1” Adjustable Gauges—Less Float MFR# 0049s02160BP 0049s02167BP

11/4” Adjustable Gauges—Less Float MFR#

Description

Webb#

dial

Webb#

11/4” - 121/2” to 193/4” Brass Head 11/4” - 191/2” to 331/4” Brass Head

359138 362436

5909S02733 5909S02733

184077 184077

MFR#

Description

Webb#

6857S11009UP 6857S13759UP 6857S14379UP 6857S17009UP 6857S18509UP

Float 24” Tank ID Float 30” Tank ID Float 32” Tank ID Float 37.5” Tank ID Float 41” Tank ID

359135 359134 359133 359132 361809

Description

Webb#

Jr. Support With 4 Floats

359140

0049s02203BP 0049s02204BP

Float Assemblies

Adjustable Kits MFR# 6287-00001k

108

Gas Equipment Catalog

victormfg.com


SECTION

6

Gauges 6200 Application Junior gauges are supplied standard with 0015-00007 Buna-N gasket and four 0040-00414 zinc-plated steel mounting screws (1/4” — 28 X 7/8”) for attachment to a gauge adapter with 2.03” [51,5] diameter bolt circle (see Rochester Machining Standard MS-501). Models 6281 and 6284 Junior gauges used on above ground ASME storage tanks are equipped with direct reading 5323S01749 percentage dials. Model 6281 Junior gauges used on below ground ASME storage tanks are equipped with direct-reading 5323S01813 percentage dials. Models 6241 and 6244 Junior gauges used on ASME motor fuel tanks are equipped with direct-reading 5323S01789 fractional dials.

Model number = 6244 Support length = 71/2” Tank Diameter = 14” Mfg date = B75 NOTE: Gauge head may also be stamped with model & unique suffix #.

When ordering, specify: 1. Gauge head size, Jr., Sr., or model #. 2. Tank diameter as shown on nameplate. 3. Mounting location (top, side, end or angle). 4. If gauge is angle mounted, state angle. 5. If gauge is end mounted, state the shape of the tank head, hemispherical or semi-ellipsoidal. 6. The “H” dimension, the distance in inches from the surface of the tank to the top of the gauge opening. To order replacement gauge, simply furnish the information stamped on one of the flat sections on the side of the gauge head as shown in the example.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

109

6 gauges

6244 - 71/2”- 14 B75

General Specifications Temperature Range Standard range is -40°F to 158°F, -40°C to 70°C. Accuracy Dependent on proper sizing of gauge and tank configuration. When equipped with Jr.™ dial, overall accuracy is ±5%, Sr.™ dial is ±3%, TwinSite™ sender is ±5%, 4” dial is ±3%. Humidity For high humidity below ground or under chassis applications, brass, stainless steel, or painted aluminum heads are recommended. Shock & Vibration Suitable for mobile service applications. Current 200 mA maximum on TwinSite™ versions. System Voltage 12 to 24 volts on TwinSite™ versions. Working Pressure 375 psi. [25,8 Bar] Approvals Gauges are UL listed for LP Gas service applications.


SECTION

6

Gauges 6300 Series

Application The 6300 Series Magnetel™ liquid-level gauges are designed to accurately determine the percentage of total tank volume for most liquids in stationary-storage applications. UL listed for LP Gas and NH3 service. General Information & Features These Magnetel™ Gauges are available in four basic models: Model 6336 — Incorporates 4” [100 mm] dial and is designed for top mounting. Model 6360 — Incorporates 8” [200 mm] dial and is designed for top mounting. Model 6339 — Incorporates 4” [100 mm] dial and is designed for side, end or angle mounting. Model 6342 — Incorporates an 8” [200 mm] dial and is designed for side, end or angle mounting. The large, easy-to-read dials are also easy to remove and replace. Materials of construction vary depending on the types of liquids to be gauged. Many different optional fea- tures are available to meet your specific needs. These materials and options, along with their pricing impact, are summarized for each model in price list 6300. Magnetel™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.

Ceramic Pointer Magnet Alnico Magnet High and Low Float Arm Stop

99/16” [243] Diameter

140º Float Travel

29/16” [65] From Tank Flange Maximum

Drawing A 4.75” [120] 2” NPT 2.32” [59]

MFR# 0022-00029

3.5” [89]

Drawing B 4.75” [120] 2” NPT 1.93” [49]

3.5” [89]

0022-00525

MATES WITH 6300 Series Y6300 Series Only

TYPE 21/2” NPT 2” NPT sch. 80

material Forged Steel

threads 1/2” - 13 UNC-2B

dimensions

Webb#

Reference dwg A

275098

Reference dwg B

When Ordering, Specify: 1. Liquid to be gauged and specific gravity. 2. Inside diameter of tank, head style: ellipsoidal, semi-ellipsoidal or hemispherical. 3. Complete model number desired from price list 6300, (example M6342-11). 4. Prefix letters for available options from price list 6300. 5. If a dial other than standard is required, furnish drawing and/or details. 6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installa tion in vertical tanks. 7. Tank mounting flange, if required (see chart). NOTE: The dimensions of the threaded neck on this adapter are equivalent to Schedule 80 pipe. CAUTION: For LP Gas or NH3 applications requiring 2” NPT connection, specify Y6300 Series Magnetel™ gauges which includes 0022-00525 schedule 80 adapter assembled to gauge.

110

Gas Equipment Catalog

victormfg.com


SECTION

6

Gauges Magnetel™ Rough Rider™ Liquid-Level Gauges M6300

Application The M6300 series Magnetel™ Rough Rider™ gauges were designed to withstand the vibration and shock inherent in mobile service. Their service life in over-the-road and off-road transports, carrying liquids ranging from LP-gas to crude oil, is unsurpassed. These gauges allow a continuous reading between 5% and 95% of tank contents. General Information & Features The Magnetel™ Rough Rider™ gauges are to be installed in the side or end of mobile tanks at the centerline. They are equipped with an exclusive spring controlled shock absorber on the float arm which substantially reduces the stress that quickly destroys conventional gauges. Angle mounting gauges are also available. The M6339 incorporates a 4” [100 mm] dial and the 6342 incorporates an 8” [200 mm] dial. When necessary, the dials are easily replaceable. Refer to price list P6300 for available types, part numbers, etc., as well as other replacement parts and accessories. Price list M6300 includes information on materials of construction, available options, and sales and pricing policy. The Magnetel™ Rough Rider™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.

6

MFR# 0022-00029

MATES WITH

TYPE

material

threads

dimensions

Webb#

6300 Series

21/2” NPT

Forged Steel

1/2” - 13 UNC-2B

Reference dwg A

When Ordering, Specify: 1. Liquid to be gauged and specific gravity. 2. Inside diameter of tank heads, ellipsoidal, semi-ellipsoidal or hemispherical. 3. Complete model number desired from price list 6300, (example M6342-11). 4. Prefix letters for available options from price list 6300. 5. If a dial other than standard is required, furnish drawing and/or details. 6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installation in vertical tanks. 7. If tank mounting flange is required, order separately from chart above.

Parts and Adapters MFR#

Rough Rider-Bobtails MFR# CM6339-11-72 CM6339-11-79

dESCRIPTION

Webb#

Magnetel 72” Diameter Tank-4” Dial Magnetel 79” Diameter Tank-4” Dial

275104 275102

0015-00019 0022-00029 5137S01262 0093S00001 0040-00413 0044-00403 0044-00404

dESCRIPTION

Webb#

Gasket-Spiral Wound 21/2” MNPT 31/2” Bold Flange 4” Dial-LPG And NH3 4” Dial Brackets SS 4” Dial Bracket Screws Nut-Magnetel Flange Bolt Magnetel Flange

275100 275098 275125 275129 275135 275134 275130

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

111

gauges

Drawing A


SECTION

6

Gauges

The Eliminator™ Rotogauge Replacement For LP Gas & NH3 Service P6293 Series

Application The Eliminator™ direct-reading float gauge is a direct replacement for 1” NPT rotary-type dip-tube gauges in LP and NH3 storage tanks. These gauges are designed for larger tanks up to 84” [2134mm] in diameter. The Eliminator™ is not intended for use in filling tanks - its use is restricted to tanks with fixed liquid level gauges, used to determine when the maximum fill level has been reached. The eliminator can be used in mobile applications up to 60” [1524mm] in diameter. How To Do The Conversion 1. After the storage tank has been evacuated, remove the rotary gauge from the 1” NPT opening at the centerline of the head. Clean and re-tap the female threads. 2. Remove the 2 screws from the bezel. Put the bezel, screws and dial chamber aside for the moment. Remove the 4 mounting screws holding the gauge head to the adapter. 3. Insert the lower portion of the replacement gauge, including the float bulb, float arm, gear housing and counterbalance, into the tank opening. 4. Apply three wraps of 1/2” [12mm] wide Teflon tape, or other suitable thread sealant, to the 1” NPT threads on the steel adapter through which the gauge support passes. 5. Screw the adapter into the tank opening to achieve a leak-tight joint, and align the gauge mounting holes in the horizontal plane. 6. Using the gasket and four mounting screws supplied, attach the gauge to the adapter fingertight. Be sure the gauge is right side up, the bracket tab for locating dial chamber should be on the right. Torque the mounting screws evenly to 140/150 lbs.in., [16,4Nm] using a cross pattern. 7. Reattach the 4” dial chamber and bezel to the Senior™ gauge head brackets using the two screws supplied. 8. If you end up with the dial chamber upside down, you cannot solve the problem by rotating the bracket. You must rotate the entire gauge 180°. MFR#

MATES WITH

Webb#

Up to 44” 44” - 60” 61” - 72” 73” - 84”

— — — —

P6293-R4400 P6293-R6000 P6293-R7200 P6293-R8400

Special Order

When ordering, specify: 1. Model number. 2. Tank I.D. 3. Shape of the head. Warning: Carefully ensure that gauge and adapter are adequately protected from damage that might cause leakage of tank contents.

112

Gas Equipment Catalog

victormfg.com


SECTION

6

Gauges Magnetic Liquid-Level Gauges for LP Gas Service 7200/B7200

Application The 7200 and B7200 Series Junior™ gauges are identical except the former has a zinc diecast head and the latter has a forged-brass head. Both types have 11/4” Male NPTF threads and 2” [51] hex-wrenching sections and are equipped with direct-reading dials appropriate for the tanks in which they are installed. General Information & Features Model 7281 and B7281 direct-indicating gauges are for top mounting. When used on aboveground ASME, horizontal, domestic storage tanks, they are equipped with 5323S01749 percentage or 5323S01789 fractional dials. When used on tanks buried underground, they are equipped 5323S01813 percentage dials. Most 420# [190 kg] vertical cylinders utilize the 5323S01835 dial. For dials used on other vertical cylinders, contact Rochester. Model 7284 and B7284 gauges are for side, end or angle mounting. When used on ASME motor-fuel tanks they are equipped with 5323S01789 fractional dial. Please contact Rochester for the part numbers of the various dials used on gauges mounted in lift-truck cylinders.

Typical Gauge

When ordering, specify: 1. The tank inside diameter (shown on tank nameplate). 2. The mounting location (top, side, end or angle). 3. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline. 4. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellipsoidal). 5. The “H” dimension. This is the distance in inches from the surface of the tank to the top of the threaded opening.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

113

6 gauges

General Specifications Temperature Range Standard range is -40°F to 158°F, -40°C to 70°C. Accuracy Dependent on proper sizing of gauge and tank configuration. With direct reading dials, overall accuracy is ±5%; with TwinSite™ Sender, overall accuracy is ±5%. Current TwinSite™ versions, 200 mA. maximum Voltage TwinSite™ versions, 12 and 24 volts. Working Pressure 375 psig [25, 8 Bar]. Approvals Gauges are appropriately UL listed for LP Gas liquid-level service and/or LP Gas automotive accessories.


SECTION

6

Gauges Jr. & Sr. Gauge Installation MS-501/502 Figure A

Figure B

Is the gauge right for your application? Gauges should only be installed in applications recommended by the manufacturer. Verify that the gauge is the proper gauge for your application prior to attempting installation. The float may or may not have a counterbalance depending on the intended application. Applications for light specific gravity liquids or large tanks normally require counterbalancing of the float. The gauge, mounting gasket and mounting adapter (if applicable) must be constructed of materials compatible with the liquid to be measured and the service environ ment. The float, mounting screws and head must be adequately rated for your specific pressure and temperature service. Is the gauge the proper size? As a general rule, the float pivot point should be on the horizontal centerline of the tank when installed. The float length dimension (measured from the float pivot point to the end of the float) should be proportional to the inside tank height and is usually slightly less than 1/2 of the vertical inside height of the tank. Gauges can be constructed for side, top or angle mounting but must be installed in the position for which they are constructed. Hold the gauge by the support (see Figure A) in the intended mounting attitude and operate the float to see if it is correct for your application (see Figure B). CAUTION: Improper gauge or dial selection or application may result in inaccurate readings. Release of tank contents as well as damage to equipment and safety hazard may result if tank is overfilled. Fuel exhaustion may occur if tank contents are less than indicated. LP Gas & NH3 gauge dials require an appropriate temperature chart. WARNING: This gauge is not a substitute for a fixed liquid level gauge or weight measurement device, which may be required for filling. GAUGE REMOVAL WARNING: Should it appear necessary to remove the gauge from the tank, do not attempt removal unless under competent supervision with all due precautions taken against the hazards of released liquid or high pressure and/or flammable gas. HAZARDS: A hazard of fire or explosion may exist if proper methods are not used when removing or installing the gasket. Replace gasket if gauge head is removed. Do not reuse gasket. When reinstalling gauge align head for proper orientation of the float inside tank.

Installation Check color stripe on O.D. of gasket for material. MS – 502 Sr. Gauges

BLUE STRIPE= NEOPRENE. Order Senior™ part # 0015-00836 or Junior™ part # 001500855 recommended for anhydrous ammonia and specific refrigerant applications. RED STRIPE= BUNA-N. Order Senior™ part # 0015-00004 or Junior™ part # 001500007, recommended for specific LP Gas & petroleum applications. BROWN STRIPE = VITON. Order Senior™ part # 0015-00415 or Junior™ part # 0015-00039. WHITE GASKET = TEFLON. Order Senior™ part # 0015-00401 or Junior™ part # 0015-00405. SPIRAL WOUND TEFLON AND STAINLESS STEEL. Order Senior™ part # 0015-00462.

CAUTION: Use spiral wound gasket only with stainless steel gauge head and allen head cap screws.

A. Fit gasket onto gauge boss. B. Carefully insert float into adapter or cou pling and work gauge’s gear housing and support through adapter being careful not to bend or damage them. C. Check to see that gasket is properly sealed in adapter gasket recess. D. Align head for proper orientation of float inside of tank. Torque screws evenly in several steps to the desired torque value. When torquing use a crossing torque pattern.

CAUTION: Do not over torque. Do not re-torque later unless leaking. Over tightening may cause damage to head and gasket. SCREW SIZE DRY TORQUE GASKET TYPE 1/4 – 28 20 TO 50 IN.LBS [2,3 to 5,6 Nm] BUNA, NEOPRENE, VITON, TEFLON 5/16 – 24 30 TO 60 IN.LBS [3,4 to 6,8 Nm] BUNA, NEOPRENE, VITON, TEFLON 5/16 – 24 140 TO 150 IN.LBS [15,8 to 16,9 Nm] SPIRAL WOUND GASKET

114

Gas Equipment Catalog

victormfg.com


SECTION

6

Gauges MS-516

Figure A

These instructions are prepared to assist tradesmen and others generally familiar with liquid storage tank equipment. Consumers are not qualified to perform the installation described below. If you have any questions concerning installation or operation of the gauge, contact Rochester Gauges or one of our authorized distributors for assistance. This document is not instructions for tank filling.

Figure B

An American National Standard Pipe Threads, General Purpose (INCH)

ANSI/ASME B1.20.1-1983 (Varnish threads due to chamfer on die.)

6 MFR# 6281-15.5-30 6281-19.25-37 6281-21-41 6281-89 6281-85

TANK SIZE

Webb#

dial

Webb#

320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical

275099 275097 275096 275095 184087

5909S02733 5909S02733 5909S02733 5909S02772 5909S02772

184077 184077 184077 275109 275109

TANK SIZE

Webb#

dial

Webb#

320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical

— — — — 275101

5986S02733 5986S02733 5986S02733 5986S02772 5986S02772

184073 184073 184073 275107 275107

gauges

Jr. flange

Sr. flange MFR# 6280-00630 6280-00637 6280-00641 6280-01235 6280-192

1” NPT MFR# B8981-01232 B8981-1237 B8981-1241 B8981-01235 B8981-2009

11/4” NPT TANK SIZE 320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical

Webb# — 361808 359343 — 275106

dial

Webb#

5909S02733 5909S02733 5909S02733 5909S02772 5909S02772

184077 184077 184077 275109 275109

MFR# B7281-130 B7281-137 B7281-141 B7281-00388 B7281-00386

TANK SIZE 320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Webb# 275114 275112 275111 — 372633

dial

Webb#

5909S02733 5909S02733 5909S02733 5909S02772 5909S02772

184077 184077 184077 275109 275109

115


SECTION

6

Gauges Replacing Gaskets 115-793

NOTE: Check color stripe on O.D. of gasket for material.

Senior = 2.06” [52,3] nominal diameter — Junior = 1.56” [39,6] nominal diameter BLUE STRIPE = NEOPRENE RED STRIPE = BUNA-N BROWN STRIPE = VITON WHITE GASKET = TEFLON SPIRAL WOUND TEFLON AND STAINLESS STEEL 5/16 – 24 screw – 30 to 60 In. Lbs., [3,4 to 6,8 Nm] using a crossing pattern. 1/4 – 28 screw – 20 to 50 In. Lbs., [2,3 to 5,6 Nm] using a crossing pattern. #10 screw – 20 to 25 In. Lbs. [2,3 to 2,8 Nm] using a crossing pattern.

Replacement Dials 115-794

Advanced Matrix TwinSite™

Mfr# ROG0040-00414 ROG0040-00415

Description Screw Head, Jr. Screw Head, Sr.

Webb# 184067 184068

ROG0015-00004 ROG0015-00007

Gasket, Sr. Gauge Gasket, Mounting Jr.

184063 184064

ROG5909S02733 ROG5323S01789 ROG5909S02772 RBSRS-228

Dial, Jr. W/5-1749 Dial, Jr. f/331/2 Underground ASME Rep. Remote Level Indicator

184077 184098 275109 314605

R3D Dials-Remote Ready MFR#

Junior™ TwinSite™

5909S02733 5909S02799 5986S02733 5909S02772 5986S02772 5987S02787 5988S02788 5988S02889

Junior™ Direct Reading

dESCRIPTION

Webb#

Jr. ASME Above Ground Jr. ASME Under Ground Sr. AMSE Above Ground Jr. 10-82% Vertical 200/420’S Sr. 10-82% Vertical 200/420’S JY Taylor Style A JY Taylor Style B Jr. Taylor Vertical 420’S Style B

184077 275108 184073 275109 275107 273836 275105 359345

Jr. Dials-Direct Read MFR# 5323S01789 5714S02591 5364S01951 5AAAS02772

116

Screws and Gaskets

dESCRIPTION

Webb#

Jr. Fractional 33 1/3# Snap On 33 1/3# Snap On 200/420’s No Remote Snap On 200/420’s With Remote

184098 283967 184082 415723

Gas Equipment Catalog

MFR# 0015-00004 0015-00007 0040-00414 0040-00415 0040-00675

dESCRIPTION

Webb#

Sr. Gasket Jr. Gasket Jr. Screw Sr. Screw Jr. Screw For Brass Head

184063 184064 184067 184068 372635

victormfg.com


SECTION

6

Gauges Pressure Gauges Mfr# description webb# 21/2” Dial, 1/4” Brass Lower Mount, ABS Case ASH95449 0-30” w.c.

173954

SJIGGAUGE

0-5 PSI

84202

PROP15

0-15 PSI

36483

PROP30

0-30 PSI

36484

PROP60

0-60 PSI

36485

PROP100

0-100 PSI

36486

PROP160

0-160 PSI

36487

PROP200

0-200 PSI

36488

PROP300

0-300 PSI

36489

ASH10256

0-30 PSI

36490

ASH15039

0-600 PSI

36491

ASH14223

0-1000 PSI

36492

21/2” Dial, 1/4” Brass Back Mount, ABS Case ASH00165 0-30 PSI

77875

ASH00166

0-60 PSI

77876

ASH00167

0-100 PSI

77877

ASH00168

0-160 PSI

77878

ASH00169

0-200 PSI

176518 36496

ASH00260

0-30 PSI

36497

ASH00261

0-60 PSI

36498

ASH00262

0-100 PSI

36499

ASH00263

0-160 PSI

36500

ASH00264

0-200 PSI

36501

ASH14143

0-300 PSI

36502

21/2” Liquid Filled Dial, 1/4” Brass Lower Mount, ABS Case ASH00511 0-15 PSI

110914

ASH00512

0-30 PSI

110915

ASH00513

0-60 PSI

110916

ASH00509

0-100 PSI

110917

ASH00514

0-160 PSI

110918

ASH00515

0-200 PSI

110919

ASH00516

0-300 PSI

110920

ASH00517

0-400 PSI

110921

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

6 gauges

4” Dial, 1/4” Brass Lower Mount, ABS Case ASH12194 0-15 PSI

117


SECTION

7

Gas Pipe, Tubing & Fittings Flexible Gas Tubing MFR#

Size

Pkg. Qty webb#

Corrugated Stainless Steel 300 Series With Polyethylene Jacket TRP-SS4-375-100 3/8” 100’ Reel 216967 TRP-SS4-375-250

3/8”

250’ Reel

216966

TRPSS4-500-50

1/2”

50’ Reel

250002

TRP-SS4-500-100

1/2”

100’ Reel

219618

TRP-SS4-500-250

1/2”

250’ Reel

87389

TRPSS4-750-50

3/4”

50’ Reel

250003

TRP-SS4-750-100

3/4”

100’ Reel

219619

TRP-SS4-750-250

3/4”

250’ Reel

87390

TRPSS4-100-50

1”

50’ Reel

250001

TRP-SS4-100-180

1”

180’ Reel

87391

TRPSS4-125-50

11/4”

50’ Reel

250000

TRP-SS4-125-150

11/4”

150’ Reel

205453

TRP-SS4-150-150

11/2”

150’ Reel

219620

TRP-SS4-200-150

2”

150’ Reel

219621

Description/Dimensions

MFR# Size (inch) EDH (AGA Size)* Jacket O.D. (max.) Inside Diameter (nom.) Wall Thickness (in.)

SS4-375 3/8” 15 .668 .440 .01

SS4-500 1/2” 19 .868 .597 .01

SS4-750 3/4” 25 1108 820 .01

SS4-100 1” 31 1.38 1.040 .01

SS4-125 11/4” 37 1665 1290 .012

SS4-150 11/2” 46 1920 1525 .012

SS4-200 2” 62 2590 2060 .012

* EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity. This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.

Underground TracPipe

118

MFR#

Size

Pkg. Qty webb#

TRPUG375-100 TRPUG500-100 TRPUG750-100 TRPUG100-100 TRPUG125-100 TRPUG125-200 TRPUG150-100 TRPUG150-200 TRPUG200-200

3/8”

100’ Coil 100’ Coil 100’ Coil 100’ Coil 100’ Coil 200’ Coil 100’ Coil 200’ Coil 200’ Coil

1/2” 3/4”

1” 11/4” 11/4” 11/2” 11/2” 2”

Gas Equipment Catalog

216985 216986 216987 216988 216989 241888 S720800 242755 242756

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings Counterstrike Tubing MFR# trpcs-375-250 trpcs-500-100 trpcs-500-250 trpcs-750-100 trPcs-750-250 trpcs-100-180 trpcs-125-150 trpcs-150-150 trpcs-200-150

tubing size

pkg. qty

Webb#

3/8”

250’ Reel 100’ Reel 250’ Reel 100’ Reel 250’ Reel 180’ Reel 150’ Reel 150’ Reel 150’ Reel

368348 368349 368160 368350 368159 368344 368345 368346 368347

1/2” 1/2” 3/4” 3/4”

1” 11/4” 11/2” 2”

Installation Bulletin for CounterStrike® CounterStrike® Installation Instructions for all products date coded 0731 and higher (manufactured after July 30, 2007). CounterStrike CSST with the black, protective sleeve uses the same easy to install AutoFlare® fittings as conventional TracPipe® with the yellow jacket. CounterStrike systems are sized in the same manners as TracPipe either using Capacity Tables or other approved methods.

2.

The instructions for cutting the tubing and for making fitting connections to CounterStrike are identical to standard yellow-jacketed TracPipe. The Jacket shall remain intact as much as practical when attaching the fitting.

3.

There are no special installation requirements for CounterStrike date coded 0731 and higher. The bonding requirements for CounterStrike are per National Electrical Code NFPA 70 Article 250.104 and the National Fuel Gas Code NFPA 54. No additional bonding is required.

4.

CounterStrike date coded 0731 and higher meets building code requirements (ASTM E84) with respect to flame spread and smoke density. This permits installation in drop ceilings used as return air plenums.

5.

CounterStrike date coded 0731 and higher has thru penetration UL classifications for 1, 2 and 4 hours with the black jacket intake.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

7 gas pipe, tubing & fittings

1.

119


SECTION

7

Gas Pipe, Tubing & Fittings AutoFlare Fittings ®

Brass Fitting AutoFlare Insert

Straight Mechanical Fittings, Reducing Fittings

Straight Fitting

Reducing Fitting

MFR# type

Size pkg. qty.

TRP-FST-375 TRP-FST-500 TRP-FST-750 TRP-RST750-500 TRP-FST-1000 TRP-RST1000-750 TRP-FST-1250 TRP-FST-1500 TRP-FST-2000

3/8” (1/2” NPT)

Straight Straight Straight Reducing Straight Reducing Straight Straight Straight

1/2” 3/4”

3/4” - 1/2” NPT

1” 1” - 3/4” NPT 11/4” 11/2” 2”

webb# 216968 87393 87394 219624 87395 219625 205454 219622 219623

24/box 24/box 16/box 16/box 16/box 16/box 6/box 4/box 4/box

Termination Mount, Meter Termination MFR# type pkg. qty. Size Termination Mount

90° Termination Mount

Meter Termination

Flange Mount Fitting

TRP-TM-375 TRP-TM-500 TRP-TM-750 TRP-TM-1000 TRP-90TM-375 TRP-90TM-500 TRP-MT6-500 TRP-MT12-500 TRPMT6-750

Termination Mount Termination Mount Termination Mount Termination Mount 90° Termination Mount 90° Termination Mount 6” Meter Termination 12” Meter Termination 6” Meter Termination

12/Box 12/Box 8/Box 8/Box 8/Box 8/Box 1 ea. 1 ea. 1 ea.

3/8”

Flange Fittings TRP-BFF-375 TRP-BFF-500 TRP-BFF-750 TRP-BFF-1000 TRP-BFF-1250 TRP-TERM-BRAC TRP-ELLS-375 TRPFGP-ELLS-500

Iron Flange Brass Iron Flange Brass Iron Flange Mount Brass Iron Flange Mount Brass Iron Flange Mount Brass Flange Bracket 90° Elbow Flange Mount 90° Elbow Flange Mount

12/box 12/box 8/box 8/box 4/box 1 ea. 8/box 8/box

3/8”

webb# 217405 217406 217407 219626 217401 217402 246855 246856 250428

1/2” 3/4”

1”

3/8” 1/2” 1/2” 1/2” 3/4”

1/2”

3/4” 1” 11/4” All 3/8” 1/2”

Grounding Clamps VCTC11N 1/2”, 3/4” 1” VCTC22 11/4” - 2” 90° Elbow Flange Mount

372312 372313

Mounting Bracket

TracPipe by Pipe Outlet

TracPipe by TracPipe Outlet MFR# type

Size

Pkg. Qty webb#

TRP-TF500-T500 TRP-TF750-T750 TRP-TF1000T1000 TRP-TF750-T500 TRP-TF1000-T500 TRP-CPLG-375 TRP-CPLG-500 TRP-CPLG-750 TRP-CPLG-1000

1/2” X 1/2”

14/box 12/box 10/box — — 24/box 24/box 16/box 16/box

120

216975 87398 87399 87376 216976 222077 216981 216982

Tee Tee Tee Tee Tee Coupling Coupling Coupling Coupling

3/4” X 3/4”

1” X 1”

1/2” X 3/4”

1” X 3/4” 3/8” 1/2” 3/4” 1”

Gas Equipment Catalog

260025 222079 263584 222081 222082 216977 216978 216979 216980

MFR# type

Size

TRPT500-500 TRPT750-750 TRPT750-500 TRPT1000-1000

1/2” FIP

Tee

Tee Tee Tee Tee

Coupling

3/4” FIP

3/4” X 1/2” FIP

1” FIP

webb# 222078 222084 308740 222080

TracPipe by Pipe Outlet Tee

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings Accessories Spare Split Rings

Full Striker Plate

MFR#

Size

webb#

TRPRING-375 TRPRING-500 TRPRING-750

3/8” Spare 1/2” Spare 3/4” Spare

222083 242572 247210

Striker Plates Half Striker Quarter Striker

MFR#

Description

Size

TRPSP-025 TRPSP-050 TRPSP-100 TRPFGP-SF-617

Quarter Striker Plate Half Striker Plate Full Striker Large Plate

3” X 2” 500/box 3” X 7” 100/box 3” X 12” 50/box 61/2” X 17”

Pkg. Qty

webb# 87381 87380 87379 276535

Floppy Galvanized Steel Conduit Floppy Strip Wound Conduit

Coated Manifold

MFR#

Description Size

Pkg. Qty

TRPFPY-375 TRPFGP-FPY-500 TRPFGP-FPY-750 TRPFGP-FPY-1000 TRPFPY-1250 TRPFPY-1500

Floppy Fits 3/8” Floppy Fits 1/2” Floppy Fits 3/4” Floppy Fits 1” Floppy Fits 11/4” Floppy Fits 2”

50’ Coil 50’ Coil 25’ Coil 25’ Coil 25’ Coil 25’ Coil

3/4”

1” 11/4” 11/2” 2” 21/2”

webb# 216969 216970 216971 216972 205456 216973

Manifolds

Manifold Bracket

Description

Size

Pkg. Qty

TRP-MI-PC TRP-MB2 TRPTERM-BRAC TRPP-LC TRPFGP-MI-PC-1X

Coated Manifold Manifold Bracket Flange L Bracket Load Center With Bracket Coated Manifold

3/4” X 1/2” X 1/2” (4)

1 ea. 1 ea. 1 ea. 1 ea. 1 ea.

* * * 11/4” X 1” X 3/4” (4)

Vent Tees

(Use when required by local codes)

(Two required for each run)

Vent Tees

246854 217403 222077 216983 256174

Underground TracPipe Accessories Shrink Cuffs

Shrink Cuffs

webb#

MFR# TRPHST-12 TRPHST-34 TRPHST-1 TRPHST-300 TRPHST-350-6 TRPHST-2

Size 1/2” 3/4” 1” 11/4” 11/2” 2”

MFR# TRPVT-125 TRPVT-150 TRPVT-200

webb# 216991 216992 216993 216994 242757 242758

Size webb# 3/8” and 1/2” 216996 3/4” and 1” 216997 242759 11/4”

Pipe Wrap

TracPipe Tools

Tube Cutter

MFR#

Desc.

TRPTC-151 TRPTC-152

Tube Cutter for 3/8” – 11/4” Tube Cutter for 11/4” – 2”

TracPipe Pipe Wrap webb# 205455 216984

MFR#

Desc.

TRP915-10H-12

Yellow Outdoor

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

7 gas pipe, tubing & fittings

Load Center With Bracket

MFR#

webb# 242814

121


SECTION

7

Gas Pipe, Tubing & Fittings Coated Copper Tubing For Natural Gas and Liquefied Petroleum Gas Copper has proven to be reliable and economical source for interior natural gas and liquefied petroleum installations for over 25 years. It’s use has introduced vertical subdivision concepts, individual metering and new add-on markets. Copper’s demand ranges from single-family dwellings to row houses to multi-story apartments. Within these dwellings, gas can be a source for furnaces, room heaters, air conditioning units, gas-fired heating boilers and domestic hot water heaters. Gas also economizes the use of cooking ranges, clothes dryers, gas fireplaces, gas barbeques and decorative gas lamps. mfr# size webb# General Purpose, Yellow Coating 190668 KMCPC38OD50 3/8” X 50” 190669 KMCPC12OD50 1/2” X 50” 190670 KMCPC58OD50 5/8” X 50” 190671 KMCPC380D100 3/8” X 100” 190672 KMCPC120D100 1/2” X 100” 190673 KMCPC580D100 5/8” X 100” 191023 KMCPC380D250 3/8” X 250” 191024 KMCPC120D250 1/2” X 250” 245837 KMCPC580D250 5/8” X 250” Oil Tech, Orange Coating KMC38X50CTD 3/8” X 50” 1/2” X 50” KMC12X50CTD KMC38X100CTD 3/8” X 100” KMC12X100CTD 1/2” X 100”

201445 213315 201446 213316

Type “L” KMCPC38L60 KMCPC12L60 KMCPC58L60 KMCPC38L100 KMCPC12L100

190674 190675 190676 191820 191821

3/8” X 60” 1/2” X 60” 5/8” X 60”

3/8” X 100” 1/2” X 100”

Can Gas-Tec be used underground? Yes, our material can be direct buried. In Canada, Gas-Tec G/Gas is currently the only tubing that can be used both above and below ground without any modification. In the United States, most areas allow Gas-Tec Refrigeration grade or Type “L” tubing to be buried, but we recommend our Gas-Tec type “L” (G/Gas) due to the heavier wall thickness on most sizes.

Standard Copper Tubing MFR #

Type L-G/Gas, ASTM B88/B837 nominal outside wall standard size diameter thickness lengths* 1/4” L

3/8” G/Gas

1/2”L

5/8” G/Gas

3/8”L 5/8”L 3/4”L

.030” .035” .040” .042” .045”

1/2” G/Gas 3/4” G/Gas 7/8” G/Gas

30’ 60’ 100’ 250’ 30’ 60’ 100’ 250’ 30’ 60’ 100’ 250’ 30’ 60’ 100’ 30’ 60’ 100’

* Custom sizes available upon request

General Purpose, ASTM B68/B280 Refrigeration outside wall standard diameter thickness lengths* 3/8” 1/2” 5/8”

122

.032” .032” .035”

Safer Installation for Gas Easy to Identify • Permanent yellow polyethylene coating. • Continuous line marking. • Traceable back to origin of manufacturing. • Mill test reports available upon request. Easy to Install • No additional training required for installation. • Flexible • Easy to join • Compact size • Requires smaller and fewer tools than steel pipe. • Cleaner than threaded steel pipe. Cost Efficient • Most economical line-marked tubing on the market. • Minimal labor costs due to quick and easy installation. • No on-site sleeving required for underground gas lines. Recyclable • Copper is fully recyclable.

25’ 50’ 100’ 250’ 25’ 50’ 100’ 250’ 25’ 50’ 100’ 250’

Gas Equipment Catalog

SIZE LENGTH WEBB#

refrigeration tubing C/T38OD 3/8 50 C/T38OD100 3/8 100 C/T12OD 1/2 50 C/T12OD100 1/2 100 C/T58OD 5/8 50 C/T58OD100 5/8 100 K Tubing C/T38K60 3/8 60 C/T38K100 3/8 100 C/T12K60 1/2 60 C/T12K100 1/2 100 C/T58K60 5/8 60 L Tubing C/T38L60 3/8 60 C/T38L100 3/8 100 C/T12L60 1/2 60 C/T12L100 1/2 100

2582 58835 2583 58836 2584 58837 2526 191720 2539 150326 111921 2552 190614 2553 91639

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings Gates Bulk Hose Spiral Reinforced

Series 7132 LP Gas Hose

Features a smooth, abrasion resistant cover and the flexibility of the 4 spiral reinforcements result in a hose that is easier to handle and glides smoothly over any surface. • Tube: Black Nitrile. • Cover: Perforated Black Neoprene. • Reinforcement: Multiple Textile Braids. • Temp. Range: -50°F to 180°F.

Underground PE Gas Pipe MFR#

SIZE WEBB# 378760 193140 319632 193141 183524 165738 165739 165740 183399 165571 263102 165741 165742 183429 183525 165572 165743 165744 183430 165573 165745 165746 183431

mfr# HFBLP350X34X1FT HFBLP350X34X3FT HFBLP350X34X12FT HFBLP350X34X18FT HFBLP350X34X20FT HFBLP350X34X50FT HFBLP350X1X15FT HFBLP350X1X100FT HFBLP350X1X150FT

DESC. Webb# 3/4” X 1 FT 438652 3/4” X 3 FT 438653 3/4” X 12 FT 438654 3/4” X 18 FT 438655 3/4” X 20 FT 438656 3/4” X 50 FT 438657 1” X 15 FT 438658 1” X 100FT 438659 1” X 150 FT 438660

Drip Leg Packages mfr# size Webb# 3/8” X 3” 184977 DLKDL6-3 1/2” X 3” 184978 DLKDL8-3 1/2” X 6” 184979 DLKDL8-6 3/4” X 3” 184975 DLKDL12-3 3/4” X 6” 184976 DLKDL12-6

7 gas pipe, tubing & fittings

YGP12CTS090-75 1/2 CTS X 75’ YGP12CTS090-100 1/2 CTS X 100’ YGP12CTS090-150 1/2 CTS X 150’ YGP12CTS090-200 1/2 CTS X 200’ YGP12CTS090-500 1/2 CTS X 500’ YGP12SDR93-100 1/2 IPS X 100’ YGP12SDR93-150 1/2 IPS X 150’ YGP12SDR93-200 1/2 IPS X 200’ YGP12SDR93-500 1/2 IPS X 500’ YGP34SDR11-50 3/4 IPS X 50’ YGP34SDR11-75 3/4 IPS X 75’ YGP34SDR11-100 3/4 IPS X 100’ YGP34SDR11-150 3/4 IPS X 150’ YGP34SDR11-500 3/4 IPS X 500’ YGP1CTS099-500 1 CTS X 500’ YGP1SDR11-100 1 IPS X 100’ GP1SDR11-150 1 IPS X 150’ YGP1SDR11-200 1 IPS X 200’ YGP1SDR11-500 1 IPS X 500’ YGP114SDR11-100 1-1/4 IPS X 100’ YGP114SDR11-150 1-1/4 IPS X 150’ YGP114SDR11-200 1-1/4 IPS X 200’ YGP114SDR11-500 1-1/4 IPS X 500’ YGP112SDR11-150 1-1/2 IPS X 150’ YGP112SDR11-500 1-1/2 IPS X 500’ YGP2SDR11-100 2 IPS X 100’ YGP2SDR11-200 2 IPS X 200’ YGP2SDR11-500 2 IPS X 500’

Certified & Tested

In-Line Trap mfr# Description Webb# VCT93UT-08 In-Line Low 361067 Pressure Sediment Trap

165575 183432 165749 165751 183433

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

123


SECTION

7

Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems Lower Installation Costs — Fewer Repairs Over Time

The LYCOFIT® connection system by Lyall, which requires no pipe preparation or special training, is much easier and faster to install compared to other mechanical fittings, electrofusion, and thermal fusion methods. Even more important is that installation failures due to bad pipe cuts, poor fusion, and weak connections are eliminated in the process. Add to that the durability of Lyall chemically resistant fittings and you will no longer have to concern yourself with re-installation due to typical joint failures.

Residential Application

Lyall provides a wide variety of product sizes and configuration to meet residential needs. ®

LYCOFIT Mechanical Fittings

• 100% leak-proof, easy to install • Cost effective, maintenance free joining system • Unprecedented performance levels and proven reliability • Excellent durability resistant to harsh chemicals and cracking • Simple installation, no fusion equipment required • No measuring or calculating required • Absolutely no slippage or pull-out

124

LYCOFIT® is a mechanical fitting for connecting underground Polyethylene (PE) gas piping systems. Lyall offers over 900 configurations allowing for varied installation requirements. Patented 100% Leak-Proof Design The LYCOFIT® fitting takes advantage of the natural sealing properties of the PE pipe, in a superior patented design that uses a barbed spigot to seal the inside diameter (ID) of the PE gas pipe, and a completion sleeve that provides the force necessary for a leak-proof, reliable connection every time. By using the polyethylene as the gasket material, this assures a positive seal between the coupling and the pipe regardless of the outside condition of the pipe. The system eliminates the use of O-rings and rubber gaskets that could leak on scratched pipe or deteriorate under adverse conditions like exposure to chemicals. Compact LYCOFIT® designs allow for installation in confined spaces.

Eliminates Pull-Out The design provides a connection so strong that it provided enough gripping power to eliminate pull-out 100% of the time. In ASTM Quick Burst and Tensile Testing, PE Pipe fails before the LYCOFIT® coupling every time! Instant Visual Check LYCOFIT® provides the installer with a full visual quality check — first “pipe-on” and the “sleeve on” in each installation for a gas tight connection.

Gas Equipment Catalog

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings

R.W. Lyall Propane Piping Systems (continued) LYCOFIT® Mechanical Fittings mfr# description PE Pipe to Copper Tube Adapter LYCLC375010B-GCR 3/8” O.D. Flare X 1/2” CTS LYCLC500010B-GCR 1/2” O.D. Flare X 1/2” CTS

webb#

179091 179093

Double End Couplings

LYCLC010B-DER LYCLC030B-DER LYCLC030D-DER LYCLC050W-DER LYCLC060Y-DER LYCLC070Y-DER LYCLC080X-DESR LYCLC090Y-DESR LYCLC200Y-DESR

1/2” CTS 1” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 11/2” IPS 2” IPS

183448 179004 179005 183453 183449 183450 183451 179012 183452

Stop & Go Couplings

LYCLC010B-SGR LYCLC050W-SGR LYCLC060Y-SGR

1/2” CTS 1/2” IPS 3/4” IPS

179025 179027 179028

Reducer Couplings

1” CTS X 1/2” CTS 1” CTS X 3/4” IPS 11/4” CTS X 1/2” CTS 1/2” IPS X 1/2” CTS 3/4” IPS X 1/2” CTS 3/4” IPS X 1/2” IPS 1” IPS X 1/2” CTS 1” IPS X 1/2” IPS 1” IPS X 3/4” IPS 1” IPS X 1” CTS 11/4” IPS X 3/4” IPS 11/2” IPS X 3/4” IPS 11/2” IPS X 1” IPS 2” IPS X 1” IPS 2” IPS X 11/4” IPS 2” IPS X 11/2” IPS 2” IPS X 3/4” IPS

179066 179068 179069 179073 193507 179074 179077 183465 179080 179081 359260 359259 359261 360328 179084 355654 359262

LYCLC010B-3TR LYCLC030B-3TR LYCLC050W-3TR LYCLC060Y-3TR LYCLC070Y-3TR LYCLC080X-3TR LYCLC200Y-3TR

1/2” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 2” IPS

179029 179031 183470 183467 179037 183520 183469

1/2” IPS 1/2” CTS

1” CTS 3/4” IPS 1” IPS 11/4” IPS 2” IPS

183462 179040 179042 183458 183459 183460 183461

11/4” IPS 2” IPS

179086 179087

1/2” CTS 1/2” IPS 3/4” IPS

179014 183457 179021 183455 179023 179024

90° Elbow Couplings

LYCLC050W-ELR LYCLC010B-ELR LYCLC030B-ELR LYCLC060Y-ELR LYCLC070Y-ELR LYCLC080X-ELR LC200Y-ELR Repair Couplings LYCLC080X-DER LYCLC200Y-DER End Caps

LYCLC010B-ECR LYCLC050W-ECR LYCLC060Y-ECR LYCLC070Y-ECR LYCLC080X-ECR LYCLC200Y-ECR

1” IPS 11/4” IPS 2” IPS

Steel Pipe to PE Pipe Transitions

Reducing Tees LYCLC050W050W010BR LYCLC020B020B010BR LYCLC070Y070Y10BR LYCLC070Y070Y60YR LYCLC080X080X030BR LYCLC060Y060Y010BR

1/2” IPS X 1/2” IPS X 1/2” CTS 3/4” X 3/4” X 1/2” CTS 1” X 1” IPS X 1/2” CTS 1” X 1” IPS X 3/4” IPS 11/4” X 11/4” IPS X 1” CTS 3/4” CTS X 3/4” IPS X 1/2” CTS

202396 194154 194161 194164 194169 202397

LYCLC050S050W-SPB 1/2” NPT X 1/2” IPS LYCLC060S060YSPB 3/4” NPT X 3/4” IPS LYCLC070S070YSPB 1” NPT X 1” IPS LYCLC080S080XSPB 11/4” NPT X 11/4” IPS LYCLC200S200YSPB 2” NPT X 2” IPS

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

274130 183510 183511 183512 179062

125

7 gas pipe, tubing & fittings

LYCLC030D010B-RR LYCLC030D060Y-RR LYCLC040B010B-RR LYCLC050W010B-RR LYCLC060Y010B-RR LYCLC060Y050W-RR LYCLC070Y010B-RR LYCLC070Y050W-RR LYCLC070Y060Y-RR LYCLC070Y030B-RR LYCLC080X060Y-RR LYCLC090Y060Y-RR LYCLC090Y070Y-RR LYCLC200Y070Y-RR LYCLC200Y080X-RR LYCLC200Y090Y-RR LYCLC200Y060Y-RR

mfr# description Webb# 3-Way Tee Couplings


SECTION

7

Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems (continued) Lyall Risers

Chamfer Tools mfr# description LYC0000-33-5647-00 Chamfer Tool 1/2” IPS X 1/2” CT LYC0000-33-5481-00 Chamfer Tool 3/4” IPS X 1/2” CTS LYC0000-33-5516-00 Chamfer Tool 1” IPS X 3/4” IPS LYC0000-33-6580-10 Chamfer Tool 11/4” IPS LYC0000-33-6580-16 Chamfer Tool 11/2” IPS LYC0000-33-6580-17 Chamfer Tool 2” IPS

webb# 269235 269231 269234 371813 269646 371809

LYCOFIT® Mechanical Tapping Tees mfr# description Mechanical Tapping Tees

LC080010B-TTR LC080030D-TTR LC080070Y-TTR LC200010B-TTR LC200050W-TTR LC200060Y-TT

11/4” IPS X 1/2” CTS 11/4” IPS X 1” CTS 11/4” IPS X 1” IPS 2” IPS X 1/2” CTS 2” IPS X 1/2” IPS 2” IPS X 3/4” IPS

webb#

179131 179133 179143 198639 179154 355653

Test Cap, Mechanical Tapping Tees LCTESTCAP Fits All Lyall Mechanical Tapping Tees Wrench, “T” Handled LYCLCT

LYCSTDLY050010T LYCSTDLY060010T LYCSTDLY060050T LYCSTDLY060060T LYCSTDLY070010T LYCSTDLY070030T LYCSTDLY070050T LYCSTDLY070060T LYCSTDLY070070T LYCKPLGS080080C-T LYCSTDLY090090T LYCSTDLY200200T

1/2” NPT X 1/2” CTS 3/4” NPT X 1/2” CTS 3/4” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS 1” NPT X 1/2” CTS

1” NPT X 1” CTS 1” NPT X 1/2” IPS 1” NPT X 3/4” IPS 1” NPT X 1” IPS 11/4” NPT X 11/4” IPS 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS

193302 192989 180062 180063 193893 193894 193895 193896 183406 370409 193897 193898

3/4” NPT X 1/2” CTS 3/4” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS 1” NPT X 1/2” CTS 1” NPT X 1/2” IPS 1” NPT X 3/4” IPS

192494 192628 192630 192631 192632 192634

Anodeless Flexible Riser LYCSTDLY060010FXT LYCSTDLY060050FXT LYCSTDLY060060FXT LYCSTDLY070010FXT LYCSTDLY070050FXT LYCSTDLY070060FXT

Anodeless LPG Flexible Tank Risers

For Lycofit® Mechanical Tapping Tee Cutter

Transition Fittings mfr# description Threaded Steel End

mfr# description Webb# Anodeless 90° Bend Rigid Riser

webb#

LYCSTDLY050010FXPGS LYCSTDLY050050FXPGS LYCSTDLY060060FXPGL

1/2” NPT X 1/2” CTS Short 1/2” NPT X 1/2” IPS Short 3/4” NPT X 3/4” NPT Long

252451 252452 252456

Service Head Risers— No Coupling Required LYCLT050S010B-BT LYCLT050S050W-BT LYCLT060S060Y-BT LYCLT070S030B-BT LYCLT070S070Y-BT LYCLT080S080Y-BT LYCLT090S090Y-BT LYCLT200S200Y-BT

1/2” NPT X 1/2” CTS 1/2” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS

1” NPT X 1” CTS 1” NPT X 1” IPS 11/4” NPT X 11/4” IPS SDR11 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS

263208 283833 198865 202405 198870 215554 202399 202400

Lyall Polyethylene Ball Valves Available through special order: Sizes , 1/2” CTS — 2” IPS

126

Gas Equipment Catalog

mfr# description Webb# lycshafc050010b-36 36” 1/2” npt x 1/2” cts 261875 36” 1/2” npt x 1/2” ips 261876 LYCSHAFC050050W-36 LYCSHAFC060010B-36 36” 3/4” npt x 1/2” cts 261877 LYCSHAFC060050W-36 36” 1/2” npt x 1/2” ips 261878 LYCSHAFC060060Y-36 36” 3/4” npt x 3/4” ips 261879 LYCSHAFC050010B-48 48” 1/2” npt x 1/2” cts 261880 LYCSHAFC050050W-48

LYCSHAFC060010B-48 LYCSHAFC060050W-48 LYCSHAFC060060Y-48 LYCSHAFC050010B-84

LYCSHAFC050050W-84 LYCSHAFC060010B-84 LYCSHAFC060050W-84 LYCSHAFC060060Y-84 LYCSHA-CFCY10-SEAL LYCSHA-CFCY14-SEAL

48” 1/2” npt x 1/2” ips 48” 3/4” npt x 1/2” cts 48” 3/4” npt x 1/2” ips 48” 3/4” npt x 3/4” ips 84” 1/2” npt x 1/2” cts 84” 1/2” npt x 1/2” ips 84” 3/4” npt x 1/2” cts 84” 3/4” npt x 1/2” ips 84” 3/4” npt x 3/4” ips 1/2” cts Service Head Gasket 1/2” ips Service Head Gasket

261881 261882 261883 261884 261885 261886 261887 261888 261889 269409 269408

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems (continued) Accessories for QRP Tool mfr# description Pipe Jaw Vise-Grip LYCAPJ070 LF-BOXQRP

webb#

1/2” CTS

3/4” CTS / 1/2” IPS

1” CTS / 3/4” IPS 11/4” CTS / 1” IPS Tool Box for QRP-100

183540 179097 179098 183518 179100

Time is money

To make sure you do each operation quickly, easily, and properly every time Lyall offers the right tools to assure the job is done correctly.

Accessories for LAP Tool mfr# description Pipe Clamp

LYCAPJ200PB-01 LYCLF-BOXLAP

webb#

Standard – 11/4” IPS Standard – 11/2” IPS Standard – 2” IPS Pull-Back – 2” IPS Tool Box for LAP-100

179105 193027 179107 179108 179109

7

Tools that make every job quick and easy. LYCOFIT® Tools allow for quick and easy installation of LYCOFIT® fittings. These tools provide perfect alignment and precision installment each and every time, without special training or time consuming measurements required. Quick Ratchet Press (QRP-100) The QRP-100 is a light weight, durable, single ratchet field assembly tool that installs all LYCOFIT® couplings from 1/2” CTS/IPS through 1” CTS. Dual Quick Ratchet Press (QRP-200) Designed for manual installations, the dual ratchet design of the QRP-200 makes it simple to install of medium to large sized piping systems. Installs all LYCOFIT® couplings from 3/4” IPS through 2” IPS. mfr# description LYCQRP-100 1/2” CTS — 1” IPS LYCQRP-200 3/4” CTS — 2” IPS

webb# 179095 252450

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

127

gas pipe, tubing & fittings

LYCOFIT® Installation Tools


SECTION

7

Gas Pipe, Tubing & Fittings

R.W. Lyall Propane Piping Systems (continued) Large Auto Press (LAP-100) This heavy duty hydraulic tool is designed to provide thousands of worry free installations quickly and easily. Installs 11/4”, 11/2” and 2” IPS LYCOFIT® couplings. mfr# description Hydraulic Tool & ENERPAC™ LYCLAP100 11/4” IPS — 2” IPS LYCAHP100 ENERPAC™ LYCHYDPRESS Kit

webb# 183440 183535 191819

LycoRing® Lightweight, disposable plastic ring that easily slips over the PE pipe and securely grips the pipe while inserting the pipe onto the LYCOFIT® spigot. The LycoRing® is included with the matching LYCOFIT® fitting and can be used with all LYCOFIT® configurations that use QRP and LAP tools, including tapping tee outlets. LycoRing® is provided with each LYCOFIT® fitting and eliminates the need for additional gripping tools to install fittings. Specifications • Meets or exceed all requirements for the Categorization of Mechanical Fittings within ASTM D2513-90c Category 1, and requirements from the Code of Federal Regulations, Title 49 Part 192.281 and 192.283. • Meets or exceeds NFPA-58 – 1002, DOT and ISO requirements. • Listed with IAPMO/UPS and CSA • Conforms to the Mechanical Fitting Specification as defined in ASTM F 1924. A complete set of specifications and test results for the product are available upon request.

128

Gas Equipment Catalog

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings

7 gas pipe, tubing & fittings

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

129


SECTION

7

Gas Pipe, Tubing & Fittings

The internal seal enables each fitting to seal on scratched pipe. A seal is maintained on the smooth inside surface of the polyethylene pipe, regardless of the exterior surface of the piping. This improved seal protection creates the ultimate design for mechanical joints. Each Con-Stab fitting provides the following unique features: • Two internal seals • Fixed stiffener • Self-locking gripper • Moisture lip • Uni-body construction The Con-Stab I.D. Seal® fittings provide the user with the following advantages: • Cost effective joining method • Simple assembly • No additional assembly equipment required for installation (just chamfer pipe and push) • Expanded product line with various configurations and material options (PE 3408/4710 or PE 2406) • Uni-body design eliminating all external parts • Meets or exceeds all D.O.T., ASTM and NFPA 58 requirements Continental Industries is an ISO 9001 Certified Company. Continental’s Con-Stab I.D. Seal® product line is manufactured and tested to the following industry standards. • ASTM D 2513 “Standard Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings” • ASME B31.8-1995 “Gas Transmission and Distribution Piping Systems” • D.O.T., Title 49 of the Code of Federal Regulations, Part 192.283 (b) • NFPA 58, LP-Gas Code

Chamfer Tools The CONSTAB CHAMFER tool is required for all CONSTAB fittings. Other Manufacturere’s tools will not produce a gas-tight connection. MFR#

SIZE WEBB#

Corrugated Stainless Steel 300 Series With Polyethylene Jacket CST0000-33-6580-04 1/2” CTS 371814 CST0000-33-6580-12 1/2” IPS 411913 CST0000-33-6580-13 3/4” IPS 371810 CST0000-33-6580-08 1” CTS 411526 CST0000-33-6580-14 1 IPS 371811 CST0000-33-6580-10 1-1/4 IPS 371813 CST0000-38-6580-16 1-1/2 IPS 269646 CST0000-33-6580-17 2 IPS 371809

130

Gas Equipment Catalog

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings Service Head Risers Connection is made above-ground. No tool or fitting is required. MFR#

SIZE WEBB#

CST1253-92-1004-36 CST1253-92-1004-84 CST1253-92-1012-36 CST1252-92-1012-84 CST1353-92-1012-36 CST1353-92-1012-84 CST1353-92-1013-36 CST1353-92-1013-84

36” 1/2 NPT X 1/2 CTS 84” 1/2 NPT X 1/2 CTS 36” 1/2 NPT X 1/2 IPS 84” 1/2 NPT X 1/2 IPS 36” 3/4 NPT X 1/2 IPS 84” 3/4 NPT X 1/2 IPS 36” 3/4 NPT X 3/4 IPS 84” 3/4 NPT X 3/4 IPS

261875 261885 261876 261886 261878 261888 261879 261889

Risers without Couplings MFR#

SIZE WEBB#

CST1253-91-4604-00 CST1353-91-4604-00 CST1353-91-4612-00 CST1353-91-4613-00 CST1453-91-4614-00 CST1553-91-4615-0A CST1652-91-4616-00 CST1752-91-4617-00

1/2 NPT X 1/2 CTS 3/4 NPT X 1/2 CTS 3/4 NPT X1 /2 IPS 3/4 NPT X 3/4 IPS 1 NPT X 1 IPS 1-1/4 NPT X 1-1/4 IPS 1-1/2 NPT X 1-1/2 IPS 2 NPT X 2 IPS

193302 192989 180062 180063 183406 414143 193897 193898

7

Risers with Couplings SIZE WEBB#

CST1253-91-4604-25 CST1353-91-4604-25 CST1353-91-4612-25 CST1353-91-4613-25 CST1453-91-4614-25 CST9953-99-0503-25 CST1652-91-4616-25 CST1752-91-4617-25

1/2 NPT X 1/2 CTS 3/4 NPT X 1/2 CTS 3/4 NPT X 1/2 IPS 3/4 NPT X 3/4 IPS 1 NPT X 1 IPS 1-1/4 NPT X 1-1/4 IPS 1-1/2 NPT X 1-1/2 IPS 2 NPT X 2 IPS

gas pipe, tubing & fittings

MFR#

411528 411530 411533 411534 411542 411589 411547 411548

Couplings MFR#

SIZE WEBB#

CST3259-52-1004-00 CST3259-52-1012-00 CST3259-52-1013-00 CST3259-52-1008-00 CST3259-52-1014-00 CST3259-52-1015-AA CST3259-52-1016-00 CST3259-52-1017-00

1/2 CTS 1/2 IPS 3/4 IPS 1 CTS 1 IPS 1-1/4 IPS 1-1/2 IPS 2 IPS

269237 269238 269239 370557 269289 269240 269645 269241

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

131


SECTION

7

Gas Pipe, Tubing & Fittings Reducing Couplings MFR #

SIZE WEBB#

CST3259-54-1204-00 CST3259-54-1304-00 CST3259-54-1404-00 CST3259-54-1312-00 CST3259-54-1413-00 CST3259-54-1513-0A CST3259-54-1514-00 CST3259-54-1615-0A

1/2 IPS X 1/2 CTS 3/4 IPS X 1/2 CTS 1 IPS X 1/2 CTS 3/4 IPS X 1/2 IPS 1 IPS X 3/4 IPS 1-1/4 IPS X 3/4 IPS 1-1/4 IPS X 1 IPS 1-1/2 IPS X 1-1/4 IPS

269251 269252 269254 269253 269255 413038 269257 269644

Repair Couplings MFR#

SIZE WEBB#

CST3238-14-4415-AA CST3238-14-4417-00

1-1/4 IPS 2 IPS

371843 269267

Tees MFR#

SIZE WEBB#

CST3259-50-1004-00 CST3259-50-1012-00 CST3259-50-1013-00 CST3259-50-1008-00 CST3259-50-1014-00 CST3259-50-1015-AA CST3259-50-1016-00 CST3259-50-1017-00

1/2 CTS 1/2 IPS 3/4 IPS 1 CTS 1 IPS 1-1/4 IPS 1-1/2 IPS 2 IPS

269212 269213 269214 370558 269215 370556 269648 269217

Reducing Tees MFR#

SIZE WEBB#

CST3259-49-1304-00 CST3259-49-1404-00 CST3259-49-1413-00 CST3259-49-1715-0A

3/4 IPS X 1/2 CTS 1 IPS X 1/2 CTS 1 IPS X 3/4 IPS 2 IPS X 1-1/4 IPS

269259 269260 269261 269262

90째 Elbows

132

MFR#

SIZE WEBB#

CST3259-51-1004-00 CST3259-51-1012-00 CST3259-51-1013-00 CST3259-51-1008-00 CST3259-51-1014-00 CST3259-51-1015-AA CST3259-51-1016-00 CST3259-51-1017-00

1/2 CTS 1/2 IPS 3/4 IPS 1 CTS 1 IPS 1-1/4 IPS 1-1/2 IPS 2 IPS

Gas Equipment Catalog

269218 269219 269220 370559 269221 370554 269647 269223

victormfg.com


SECTION

7

Gas Pipe, Tubing & Fittings Cap-N-Go Fittings MFR#

SIZE WEBB#

CST3259-57-1004-00 CST3259-57-1013-00 CST3259-57-1015-0A CST3259-57-1017-00

1/2 CTS 3/4 IPS 1-1/4 IPS 2 IPS

269224 269225 269226 269227

Cap End MFR#

SIZE WEBB#

269242 269243 269244 370555 269246

CST3259-53-1004-00 CST3259-53-1013-00 CST3259-53-1014-00 CST3259-53-1015-0A CST3259-53-1017-00

1/2 CTS 3/4 IPS 1 IPS 1-1/4 IPS 2 IPS

Pex Copper Transition Couplings MFR#

SIZE WEBB#

CST9943-99-0064-00 CST9943-99-0065-00

1/2 PE X 1/2 OD COPPER 1/2 PE X 5/8 OD COPPER

269249 269250

Underground Gas Line Markers MFR#

DESCRIPTION WEBB#

MISUD21 VCTTRACERWIRE ELE1207PE30-YE

TAPE UNDERGROUND GAS 31-140 TRACER WIRE 500’ 14A Tracer Wire 500’ 12A

7 gas pipe, tubing & fittings

183516 359306 243218

Anode Bags - 17 lbs MFR#

DESCRIPTION WEBB#

CPRANODE17 ANODE MAGNESIUM BAGS 183403

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

133


SECTION

7

Connectors Stainless Steel Gas Connectors Residential Stainless Steel Gas Appliance Connectors

Dormont’s complete line of flexible, corrugated, Supr-Safe® stainless steel connectors attach all types of gas appliances to gas utility lines. . .easily and safely. We carry the largest inventory in the business, with connectors ranging from 3/8” through 11/2” O.D. MFR# od id lENGTH tHREAD tYPE WEBB# Water Heater, Gas Log, Space Heater, Connectors With Fittings 12” 3/8 mnpt end 242096 DOR10-2121-12 3/8” 1/4” 18” 3/8 mnpt end 202067 DOR10-2121-18 3/8” 1/4” 24” 3/8 mnpt end 185424 DOR10-2121-24 3/8” 1/4” 30” 3/8 mnpt end 246859 DOR10-2121-30 3/8” 1/4” 36” 3/8 mnpt end 244976 DOR10-2121-36 3/8” 1/4” 48” 3/8 mnpt end 246858 DOR10-2121-48 3/8” 1/4” 12” 3/8 fnpt end 185448 DOR10-2222-12 3/8” 1/4” 18” 3/8 fnpt end 188283 DOR10-2222-18 3/8” 1/4” 24” 3/8 fnpt end 215474 DOR10-2222-24 3/8” 1/4” 36” 3/8 fnpt end 213164 DOR10-2222-36 3/8” 1/4” 48” 3/8 fnpt end 245962 DOR10-2222-48 3/8” 1/4” 18” 1/2 mnpt end 209723 DOR10-3131-18 3/8” 1/4” 36” 1/2 mnpt end 209724 DOR10-3131-36 3/8” 1/4” Dryer Connections With Fittings 18” 3/8 mnpt/fnpt 163856 DOR20-2122-18 1/2” 3/8” 30” 3/8 mnpt/fnpt 163857 DOR20-2122-30 1/2” 3/8” 36” 3/8 fnpt 192747 DOR20-2222-36 1/2” 3/8” 48” 3/8 fnpt 206103 DOR20-2222-48 1/2” 3/8” 12” 1/2 mnpt–3/8 fnpt 191054 DOR20-3122-12 1/2” 3/8” 18” 1/2 mnpt–3/8 fnpt 192608 DOR20-3122-18 1/2” 3/8” 24” 1/2 mnpt–3/8 fnpt 191055 DOR20-3122-24 1/2” 3/8” 36” 1/2 mnpt–3/8 fnpt 192613 DOR20-3122-36 1/2” 3/8” 48” 1/2 mnpt–3/8 fnpt 192610 DOR20-3122-48 1/2” 3/8” 60” 1/2 mnpt–3/8 fnpt 192611 DOR20-3122-60 1/2” 3/8” 72” 1/2 mnpt–3/8 fnpt 191056 DOR20-3122-72 1/2” 3/8” 12” 1/2 mnpt 166786 DOR20-3131-12 1/2” 3/8” 18” 1/2 mnpt 209421 DOR20-3131-18 1/2” 3/8” 24” 1/2 mnpt 166228 DOR20-3131-24 1/2” 3/8” 36” 1/2 mnpt 209422 DOR20-3131-36 1/2” 3/8” 48” 1/2 mnpt 166229 DOR20-3131-48 1/2” 3/8” 60” 1/2 mnpt 209423 DOR20-3131-60 1/2” 3/8” 36” 1/2 mnpt–1/2 fnpt 215815 DOR20-3132-36 1/2” 3/8” 48” 1/2 mnpt–1/2 fnpt 224158 DOR20-3132-48 1/2” 3/8” Range Connectors With Fittings 12” 1/2 mnpt 245963 DOR30-3131-12 5/8” 1/2” 18” 1/2 mnpt 218889 DOR30-3131-18 5/8” 1/2” 24” 1/2 mnpt 193511 DOR30-3131-24 5/8” 1/2” 30” 1/2 mnpt 201236 DOR30-3131-30 5/8” 1/2” 36” 1/2 mnpt 79589 DOR30-3131-36 5/8” 1/2” 48” 1/2 mnpt 179822 DOR30-3131-48 5/8” 1/2” 60” 1/2 mnpt 212867 DOR30-3131-60 5/8” 1/2” 72” 1/2 mnpt 218890 DOR30-3131-72 5/8” 1/2” 24” 1/2 mnpt–1/2 fnpt 204534 DOR30-3132-24 5/8” 1/2” 30” 1/2 mnpt–1/2 fnpt 163854 DOR30-3132-30 5/8” 1/2” 48” 1/2 mnpt–1/2 fnpt 163855 DOR30-3132-48 5/8” 1/2” 12” 1/2 fnpt 185449 DOR30-3232-12 5/8” 1/2” 18” 1/2 fnpt 68547 DOR30-3232-18 5/8” 1/2” 24” 1/2 fnpt 68548 DOR30-3232-24 5/8” 1/2” 36” 1/2 fnpt 68549 DOR30-3232-36 5/8” 1/2” 48” 1/2 fnpt 68692 DOR30-3232-48 5/8” 1/2” 60” 1/2 fnpt 185458 DOR30-3232-60 5/8” 1/2” 72” 1/2 fnpt 185460 DOR30-3232-72 5/8” 1/2”

134

Gas Equipment Catalog

victormfg.com


SECTION

7

Connectors Stainless Steel Gas Connectors (continued) Low Visibility Hearth Connectors Black mfr#

OD ID Length Thread type webb#

DOR10A-2121-12 DOR10A-212-18 DOR10A-2121-24 DOR10A-3131-12 DOR10A-3131-18 DOR10A3131-24 DOR10A-3131-30

3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”

MFR# od

1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4”

12” 18” 24” 12” 18” 24” 30”

3/8 mnpt end 3/8 mnpt end 3/8 mnpt end 1/2 mnpt end 1/2 mnpt end 1/2 mnpt end 1/2 mnpt end

308566 308567 308568 308576 308577 308578 308579

id lENGTH tHREAD tYPE WEBB#

Range Connectors With End Fittings 18” DOR30-4141-18 5/8” 1/2” 24” DOR30-4141-24 5/8” 1/2” 36” DOR30-4141-36 5/8” 1/2” 18” DOR30-4144-18 5/8” 1/2” 24” DOR30-4144-24 5/8” 1/2” 36” DOR30-4144-36 5/8” 1/2” 48” DOR30-4144-48 5/8” 1/2” 18” DOR30-4242-18 5/8” 1/2” 24” DOR30-4242-24 5/8” 1/2” 36” DOR30-4242-36 5/8” 1/2” 48” DOR30-4242-48 5/8” 1/2” 60” DOR30-4242-60 5/8” 1/2” 72” DOR30-4242-72 5/8” 1/2” 3/4” 24” DOR40-4142-24 1”

3/4 mnpt 3/4 mnpt 3/4 mnpt

3/4 mnpt–3/4” mnpt 90 3/4 mnpt–3/4” mnpt 90 3/4 mnpt–3/4” mnpt 90 3/4 mnpt–3/4” mnpt 90 3/4 fnpt 3/4 fnpt 3/4 fnpt 3/4 fnpt 3/4 fnpt 3/4 fnpt

3/4 mnpt–3/4 fnpt

213943 213944 197947 67650 55306 67651 67653 55305 67652 55307 55308 185457 185459 184568

End Fittings mfr#

Description

246634 179505 185463 209028 185462 185461

Connector Flow Capacity (Per ANSI Z21.24)

Series

Nominal connector ID, INCH

10

1/4”

20

3/8”

30

1/2”

Straight LEngth Capacity – BTU PEr Hr (w) 0.64 Sp. Gr. 1000 BTU Per Cu Ft. (37.2 MJ/m3) Gas at 0.5 Inch Water Column (124 Pa) Pressure Drop 1 foot (0.30 m) 48000 (14 067) 102000 (29 893) 180000 (52 811)

11/2 Foot (0.48 m) 43800 (12 837) 93100 (27 285) 164200 (48 122)

2 foot (0.61 m) 400000 (11 723) 85000 (24 911) 150000 (43 961)

21/2 Foot (0.76 m) 36400 (10 668) 77100 (22 742) 136000 (40 034)

3 Foot (0.91 m) 33400 (9 789) 71100 (20 837) 125000 (36 634)

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

4 foot (1.22 M) 28300 (8 294) 60500 (17 731) 106000 (31 066)

5 foot (1.52 M) 24900 (7 297) 53200 (15 591) 93200 (27 314)

6 Foot (1.83 m) 23100 (6 770) 49100 (14 390) 86000 (25 380)

135

gas pipe, tubing & fittings

Dryer 20 Series (Fittings for 1/2” OD Connectors) 1/2” fnpt For 1/2” OD (3/8” ID) DOR90-2032 3/4” fnpt For 1/2” OD (3/8” ID) DOR90-2042 Dryer 30 Series (Fittings for 5/8” OD Connectors) 1/2” mnpt For 5/8” OD (1/2” ID) DOR90-3031 3/4” mnpt For 5/8” OD (1/2” ID) DOR90-3041 DOR90-3032 1/2” fnpt For 5/8” OD (1/2” ID) 3/4” fnpt For 5/8” OD (1/2” ID) DOR90-3042

7

webb#


SECTION

7

Connectors Stainless Steel Gas Connectors (continued)

Commercial Supr-Safe® Disconnect Gas Appliance Connectors – BPQ Series Stainless Steel corrugated hose, encased in a stainless steel braid, covered with a thick SuperFlex coating and fitted with an A Type “Push-to-Connect” quick disconnect coupling.

Dormont Moveable Connector with Push-to-Connect Quick Disconnect.

mfr# description webb# 1/2” Quick Couplings 1/2” X 36” 213236 DOR1650BPQ36 1/2” X 48” 185437 DOR1650BPQ48 1/2” X 60” 185439 DOR1650BPQ60 3/4” Quick Couplings 3/4” X 36” 185435 DOR1675BPQ36 3/4” X 48” 185436 DOR1675BPQ48 3/4” X 60” 185438 DOR1675BPQ60 1” Quick Couplings DOR16100BPQ24 1” X 24” 216370 DOR16100BPQ36 1” X 36” 216371 DOR16100BPQ48 1” X 48” 204050 3/4” Quick Coupling with Restraining Device* 3/4” X 36” 163870 DOR1675BPQR36 Restraining Device Coils DORRDC-36 For 36” Commercial Flex DORRDC-48 For 48” Commercial Flex

163862 163863

SnapFast™ Connectors DORA50 1/2” Snap Fast Connector 163860 DORA75 3/4” Snap Fast Connector 163861 * Also available as kit with restraining device, special order.

BTU Flow Capacities Gas Connectors for Moveable Equipment length MFR# 1650b, 1650bp 1650bq, bpq, bpqb, bpcf 1675b, 1675bp 1675bq, bpq, bpqb, bpcf 16100b, 16100bp 16100bq, bpq, bpqb, bpcf 16125b, 16125bp 16125bq, bpq

inside dia. 1/2” 1/2” 3/4” 3/4” 1” 1” 11/4” 11/4”

12” 15,2000 98,000 326,000 260,000 652,000 425,000 1,204,000 783,000

24” 150,000 870,00 291,000 232,000 582,000 414,000 1,075,000 699,000

36” 120,000 77,000 256,000 218,000 512,000 379,000 946,000 615,000

48” 106,000 68,000 225,000 180,000 451,000 334,000 833,000 541,000

60” 93,000 60,000 198,000 158,000 397,000 294,000 733,000 476,000

72” 87,000 55,000 175,000 139,000 350,000 279,000 645,000 419,000

Gas Connectors for Moveable Equipment With Safety Quik and Supr-Swivel Fittings length MFR# 1650bpqs, bpcfs 1650bpq2s, bpcf2s 1675bpqs, bpcfs 1675bpq2s, bpcf2s 16100bpqs, bpcfs 16100bpq2s, bpcf2s

inside dia. 1/2” 1/2” 3/4” 3/4” 1” 1”

12” 92,000 88,000 242,000 230,000 396,000 377,000

24” 81,000 77,000 216,000 205,000 385,000 366,000

36” 72,000 69,000 203,000 193,000 353,000 336,000

48” 63,000 60,000 167,000 160,000 310,000 295,000

60” 56,000 54,000 147,000 140,000 274,000 261,000

72” 51,000 48,000 130,000 124,000 260,000 247,000

CSA International design certifies gas connectors for a maximum operating pressure of 0.5 psig. Capacities shown, which exceed minimum ANSI requirements, are results from independent testing laboratories. Minimum required BTU capacities for gas connectors (B & BP models) are defined by ANSI Z21.69. Flow capacities for connector assemblies exclude manual shut-off valves. BTU capacities decrease when the length of the connector increase. Flow rating BTU 0.64 SP.GR at 0.5 W.C. pressure drop.

136

Gas Equipment Catalog

victormfg.com


SECTION

7

Fittings

Brass Flare Fittings #42 Flare X Flare Union MfR# Code

Size

U2-2 U2-3 U2-4 U2-5 U2-6 U2-8 U2-10 U2-12 U2-14

1/8

SAE18UN SAE316UN SAE14UN SAE516UN SAE38UN SAE12UN SAE58UN SAEU2-12 SAE78UN

webb# 19795 19796 19797 19798 19799 19801 19802 19803 19804

3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8

#42R Flare X Flare Reducing Union MfR# Code

Size

UR2-64 UR2-86 UR2-108 UR2-84 UR2-106 UR2-128

3/8 X 1/4

SAE38X14UN SAE12X38UN SAE58X12UN SAE12X14UN SAE58X38UN SAE34X12UN

webb#

1/2 X 3/8 5/8 X 1/2 1/2 X 1/4 5/8 X 3/8 3/4 X 1/2

30291 34574 34820 34818 34819 19792

#46 Flare X Female (FPT) Union Size webb#

U3-3A U3-4A U3-4B U3-6A U3-6B U3-6C U3-6D U3-6E U3-8B U3-8C U3-8D U3-8E U3-10C U3-10D U3-10E U3-12E

3/16 X 1/8

SAE316ODX18FA SAE14ODX18FA SAE14ODXFA SAE38ODX18FA SAE38ODX14FA SAE38ODXFA SAE38ODX12FA SAE38ODX34FA SAE12ODX14FA SAE12ODX38FA SAE12ODXFA SAE12ODX34FA SAE58ODX38FA SAE58ODX12FA SAE58ODX34FA SAE34ODX34FA

1/4 X 1/8 1/4 X 1/4 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 3/4

19747 19748 19749 19754 19755 19756 19757 19758 19759 19760 19761 19762 19763 19764 19765 19767

#114 Swivel Nut Female Flare X Female Flare MfR# Code

Size webb#

1/4 US4-4 SAE14SWIVELNUT US4-6 SAE38SWIVELNUT 3/8 US4-8 SAE12SWIVELNUT 1/2 US4-10 SAE58SWIVELNUT 5/8 US4-86 SAE12X38SWIVELNUT 1/2 X 3/8 US4-108 SAE58X12SWIVELNUT 5/8 X 1/2

78995 77598 77599 78996 95739 95738

MfR# Code

Size

U1-2A U1-3A U1-4A U1-4B U1-4C U1-4D U1-5A U1-5B U1-5C U1-6A U1-6B U1-6C U1-6D U1-6E U1-8B U1-8C U1-8D U1-8E U1-10B U1-10C U1-10D U1-10E U1-12D U1-12E U1-14E LONG

1/8 X 1/8 3/16 X 1/8 3/16 X 1/4 1/4 X 1/8 1/4 X 1/4 1/4 X 3/8 1/4 X 1/2 5/16 X 1/8 5/16 X 1/4 5/16 X 3/8 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 1/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 1/2 3/4 X 3/4 7/8 X 3/4 3/8 X 3/8 3/8 X 1/2 1/2 X 1/2 5/8 X 1/2

SAE18MUN SAE316X18MUN SAE316X14MUN SAE14X18MUN SAE14MUN SAE14X38MUN SAE14X12MUN SAE516X18MUN SAE516X14MUN SAE516X38MUN SAE38X18MUN SAE38X14MUN SAE38X38MUN SAE38X12MUN SAE38X34MUN SAE12X14MUN SAE12X38MUN SAE12X12MUN SAE12X34MUN SAE58X14MUN SAE58X38MUN SAE58X12MUN SAE58X34MUN SAE34X12MUN SAE34ODX34MUN SAE78X34MUN SAE38X38MUNLNG SAE38X12MUNLNG SAE12X12MUNLNG SAE58X12MUNLNG

webb# 19769 19770 19771 19772 19773 19774 19775 19776 19777 19778 19779 19780 19781 19782 19783 19784 19785 19786 19787 19788 19789 19790 19791 368566 19793 19794 361612 361613 361614 361615

7

#446 Flare Cap Female Flare MfR# Code

Size

N5-3 N5-4 N5-5 N5-6 N5-8 N5-10

3/16 1/4 5/16 3/8 1/2 5/8

SAE316CAP SAE14CA SAE516CAP SAE38CA SAE12CA SAE58CAP

gas pipe, tubing & fittings

MfR# Code

#48 Flare X Male (MPT) Union

webb# 19735 19736 19737 19738 19739 19740

#447 Flare Plug Male Flare MfR# Code

Size Webb#

P2-4 P2-6 P2-8 P2-10

1/4 3/8 1/2 5/8

SAE14PL SAE38PL SAE12PL SAE58PL

19742 19744 19745 19746

#461 Flare Bonnets MfR# Code

Size

B1-4 B1-6 B1-8 B1-10

1/4 3/8 1/2 5/8

SAE461-4 SAE38BONNET SAE12BONNET SAE461-10

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

webb# 185393 185395 185396 185391

137


SECTION

7

Fittings Brass Flare Fittings #44 Flare X Flare X Flare Tee MfR# Code

Size

T2-2 T2-3 T2-4 T2-5 T2-6 T2-8 T2-10 T2-12

1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4

SAE18T SAE316T SAE14T SAE516T SAE38T SAE12T SAE58T SAE34T

webb# 19856 19857 19858 19859 19860 19861 19862 19863

#44R Flare X Flare X Flare Reducing Tee MfR# Code TR2-664 TR3-668 TR2-886 TR2-10106 TR2-10808 TR2-10810 TR2-868 TR2-8810

Size WEbb#

3/8 X 1/4 34826 SAE38X14T SAE38X12T 3/8 X 1/2 34827 SAE12X38T 1/2 X 3/8 34833 SAE58X38T 5/8 X 3/8 34838 SAE58X12T 5/8 X 1/2 34839 SAE58X12X58T 5/8 X 1/2 X 5/8 191825 SAE12X38X12T 1/2 X 3/8 X 1/2 192879 SAE12X58T 1/2 X 5/8 192880

#45 Flare X Flare X Male (MPT) Tee MfR# Code

Size webb#

T1-6C T1-8D T1-6B T1-10D

3/8 X 3/8 1/2 X 1/2 3/8 X 1/4 5/8 X 1/2

SAE38ODX38MT2 SAE12ODX12MT2 SAE38ODX14MT5 SAE58ODX12MT5

19872 19875 19883 19888

#481 Forged Flare Nut MfR# Code

Size Webb#

NS4-4 NS4-6 NS4-8 NS4-10 NSR4-86 NSR4-108

1/4 34570 3/8 34571 1/2 34572 5/8 34814 1/2 X 3/8 215886 5/8 X 1/2 215887

138

SAE14RNUT SAE38RNUT SAE12RNUT SAE58RNUT SAE12X38RNUT SAE58X12RNUT

Gas Equipment Catalog

#55 Flare X Flare Elbow MfR# Code

Size

E2-2 E2-3 E2-4 E2-5 E2-6 E2-8 E2-10 E2-12 ER2-64 ER2-86 ER2-106 ER2-108

1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 3/8 X 1/4 1/2 X 3/8 5/8 X 3/8 5/8 X 1/2

SAE1890 SAE31690 SAE1490 SAE51690 SAE3890 SAE1290 SAE5890 SAE3490 SAE38X1490 SAE12X3890 SAE58X3890 SAE58X1290

webb# 19847 19848 19849 19850 19851 19852 19853 19854 34823 34824 94502 94503

#49 Flare X Male (MPT) Elbow MfR# Code

Size

E1-2A E1-3A E1-3B E1-4A E1-4B E1-4C E1-4D E1-5A E1-5B E1-5C E1-6A E1-6B E1-6C E1-6D E1-6E E1-8B E1-8C E1-8D E1-8E E1-10C E1-10D E1-10E E1-12D

1/8 3/16 X 1/8 3/16 X 1/4 1/4 X 1/8 1/4 1/4 X 3/8 1/4 X 1/2 5/16 X 1/8 5/16 X 1/4 5/16 X 3/8 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 1/2

SAE18M90 SAE316X18M90 SAE316X14M90 SAE14X18M90 SAE14M90 SAE14X38M90 SAE14ODX12M90 SAE516X18M90 SAE516X14M90 SAE516X38M90 SAE38X18M90 SAE38X14M90 SAE38X38M90 SAE38X12M90 SAE38ODX34M90 SAE12X14M90 SAE12X38M90 SAE12X12M90 SAE12ODX34M90 SAE58X38M90 SAE58ODX12M90 SAE58ODX34M90 SAE34ODX12M90

webb# 19823 19824 19825 19826 19827 19828 19829 19830 19831 19832 19833 19834 19835 19836 19837 19838 19839 19840 19841 19843 19844 19845 19846

#564 Flare X Female (FPT) Elbow MfR# Code

Size Webb#

E3-6C E3-6D E3-8D E3-8E E3-10C E3-10D E3-10E

3/8 X 3/8 3/8 X 1/2 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4

SAE38ODX38F90 SAE38ODX12F90 SAE12ODX12F90 SAE12ODX34F90 SAE58ODX38F90 SAE58ODX12F90 SAE58ODX34F90

19813 19814 19818 19819 19820 19821 19822

victormfg.com


SECTION

7

Fittings

Propane Hose & Fittings Hose Barb to Male Pipe Fitting MFR# SAE14Hx18M SAE14Hx14M SAE14Hx38M SAE38Hx18M SAE38Hx14M SAE38Hx38M SAE38Hx12M

Description Webb# 1/4” I.D. Hose X 1/8” MPT 19964 1/4” I.D. Hose X 1/4” MPT 19965 1/4” I.D. Hose X 3/8” MPT 19966 3/8” I.D. Hose X 1/8” MPT 19969 3/8” I.D. Hose X 1/4” MPT 19970 3/8” I.D. Hose X 3/8” MPT 19971 3/8” I.D. Hose X 1/2” MPT 19972

Hose Barb to Female Flare Swivel MFR# SAE14Hx38FFL SAE38Hx38FFL SAE38Hx12FFL

Description Webb# 1/4” I.D. Hose X 3/8” Female Flare Swivel 110988 3/8” I.D. Hose X 3/8” Female Flare Swivel 184985 3/8” I.D. Hose X 1/2” Female Flare Swivel 223454

Hose Barb to Male Flare MFR# SAE14Hx38MFL SAE38Hx38MFL SAE38Hx12MFL

Description Webb# 1/4” I.D. Hose X 3/8” Male Flare 193397 3/8” I.D. Hose X 3/8” Male Flare 182631 3/8” I.D. Hose X 1/2” Male Flare

Hose Barb to Female Pipe Fitting Description Webb# 1/4” I.D. Hose X 1/8” FPT 184998 1/4” I.D. Hose X 1/4” FPT 19941 1/4” I.D. Hose X 3/8” FPT 19942 3/8” I.D. Hose X 1/8” FPT 185000 3/8” I.D. Hose X 1/4” FPT 19946 3/8” I.D. Hose X 3/8” FPT 19947 3/8” I.D. Hose X 1/2” FPT 19948

Hose Barb to 9/16”—18 LH Female Swivel

MFR# SAE622-201

Description Webb# 3/8” Hose Nip X 9/16”–18 LH Female Swivel 193398

Hose Barb X Soft Nose Hand Wheel POL

MFR# Description Webb# SAE14HxMPOLHW 1/4” I.D. Hose X Soft Nose Hand Wheel POL 182646

Hose Barb X POL MFR# Description Webb# 182655 SAE14HxMPOL 1/4” I.D. Hose X POL (7/8” Hex)

MFR# Description Webb# 182653 SAE14MX14MINV 1/4” I.D. Hose X 1/4” Inverted Flare Male

Gates LP Grill Hose MFR# HOS14-2 HOS3/8 HOS1/2 HOS3/4 HOS1ID

Description Webb# 1/4” Double Braid Hose 185588 3/8” Double Braid Hose 185605 1/2” Double Braid Hose 185581 3/4” Double Braid Hose 185604 1” Double Braid Hose 185591

Brass Hose Ferrule MFR# HOF7326 HOF7327 HOF7328 HOF7329 HOF7331 HOF7332 HOF7333 SPFKT-15

Size .593” .625” .656” .687” .750” — .812” —

Description Webb# Brass Hose Ferrule For 1/4” Hose 185561 Brass Hose Ferrule For 1/4” Hose 185562 Brass Hose Ferrule For 1/4” Hose 185563* Brass Hose Ferrule For 3/8” Hose 185564 Brass Hose Ferrule For 3/8” Hose 185565 Brass Hose Female for 3/8” Hose 252788* Brass Hose Ferrule For 3/8” Hose 185566 3-Hole Crimping Tool For Brass Ferrule 184210

* Use with current stock thermoid hose.

Ear Clamps & Jaw Pinchers MFR# Description Webb# OET10100011 Oetiker 2 Ear Clamp 3/8” 183382 OET14100082 Standard Jaw Pinchers 185559 OET10100016 Oetiker 2 Ear Clamp 1/2” 183383 OET10100019 Oetiker 2 Ear Clamp 9/16” (1/4” Single Braid Hose) 183384 OET10100022 Oetiker 2 Ear Clamp 19/32” (1/4” Double Braid Hose) 183385 OET10100024 Oetiker 2 Ear Clamp 5/8” (1/4” Double Braid Hose) 183386 OET10100027 Oetiker 2 Ear Clamp 3/4” (3/8” Double Braid Hose) 183388 OET10100032 Oetiker 2 Ear Clamp 15/16” 183387

Premade Hose with Male Ends MFR# SIZE (INCHES) LENGTH(FEET) VCT50A1900030 3/8 6 VCT50A1900100 3/8 12 VCT50A1900101 3/8 18 HFBLP350X12X6FT 1/2 6 HFBLP350X12X10FT 1/2 10 HFBLP350X12X15FT 1/2 15 HFBLP350X12X18FT 1/2 18 HFBLP350X12X20FT 1/2 20 HFBLP350X12X25FT 1/2 25 HFBLP350X12X50FT 1/2 50 HFBLP350X12X100FT 1/2 100

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

WEBB# 370042 370041 370040 438644 438645 438646 438647 438648 438649 438650 438651

139

7 gas pipe, tubing & fittings

MFR# SAE14Hx18F SAE14Hx14F SAE14Hx38F SAE38Hx18F SAE38Hx14F SAE38Hx38F SAE38Hx12F

Hose Barb X Inverted Flare


SECTION

7

Fittings Black Malleable Fittings

45° Elbow MFR#

SIZE WEBB#

MAL1845

1/8”

12559

MAL1445

1/4”

12560

MAL3845

3/8”

12561

MAL1245

1/2”

12562

MAL3445

3/4”

12563

MAL145

1”

12564

MAL11445

11/4”

12565

MAL11245

11/2”

12566

MAL245

2”

12567

MAL21245

21/2”

12568

MAL345

3”

12569

MFR#

90° Street Elbow MFR#

SIZE WEBB#

MAL18S90

1/8”

12547

MAL14S90

1/4”

12548

MAL38S90

3/8”

12549

MAL12S90

1/2”

12550

MAL34S90

3/4”

12551

MAL1S90

1”

12552

MAL114S90 11/4”

12553

MAL112S90 11/2”

12554

MAL2S90

12555

2”

MAL212S90 21/2”

45° Street Elbow

90° Reducing Elbow

12556

SIZE WEBB#

MAL14X1890 1/4” X 1/8”

12518

MAL38X1490 3/8” X 1/4”

12519

MAL12X3890 1/2” X 3/8”

12521

MAL12X1490 1/2” X 1/4”

12522

MAL34X1290 3/4” X 1/2”

12523

MAL34X3890 3/4” X 3/8”

12524

MAL34X1490 3/4” X 1/4”

12525

MAL1X3490

1” X 3/4”

12526

MAL1X1290

1” X 1/2”

12527

MAL114X190 11/4” X 1”

MAL114X1290 11/4” X 1/2” 12531 MAL112X11490 11/2” X 11/4” 12532 MAL112X190 11/2” X 1”

Cross

12529

MAL114X3490 11/4” X 3/4” 12530

12533

SIZE WEBB#

MFR#

SIZE WEBB#

MAL2X11290 2” X 11/2”

12535

MAL18S45

1/8”

12574

MAL14CR

1/4”

12760

MAL2X11490 2” X 11/4”

12536

MAL14S45

1/4”

12575

MAL38CR

3/8”

12761

MAL2X190

2” X 1”

12537

MAL38S45

3/8”

12576

MAL12CR

1/2”

12762

MAL2X3490

2” X 3/4”

12538

MAL12S45

1/2”

12577

MAL34CR

3/4”

12763

MAL212X290 21/2” X 2”

MAL34S45

3/4”

12578

MAL1CR

1”

12764

MAL212X11290 21/2” X 11/2” 12540

MAL1S45

1”

12579

MAL114CR

11/4”

12765

MAL3X21290 3” X 21/2”

MAL114S45 11/4”

12580

MAL112CR

11/2”

12766

MAL3X290

MAL112S45 11/2”

12581

MAL2CR

2”

12767

MAL2S45

12582

MFR#

SIZE WEBB#

MAL1890

1/8”

12503

MAL1490

1/4”

12504

MAL3890

3/8”

12505

MAL1290

1/2”

12506

MAL3490

3/4”

12507

MAL190

1”

12508

MAL11490

11/4”

12509

MAL11290

11/2”

12510

MAL290

2”

12511

MAL21290

21/2”

12512

MAL390

3”

12513

140

3” X 2”

12539 12541 12542

Plug

Coupling

90° Elbow

MFR#

SIZE WEBB#

MAL18CA

1/8”

12851

MAL14CA

1/4”

12852

MAL38CA

3/8”

12853

MAL12CA

1/2”

12854

MAL34CA

3/4”

12855

MAL1CA

1”

12856

MAL114CA

11/4”

12857

MAL112CA

11/2”

12858

MAL2CA

2”

12859

MAL212CA

21/2”

12860

MAL3CA

3”

12861

MAL112X3490 11/2” X 3/4” 12534

MFR#

2”

Cap

MFR#

SIZE WEBB#

MFR#

SIZE WEBB#

MAL18CO

1/8”

12774

Solid BCI18SOPL

1/8”

1380

MAL14CO

1/4”

12775

BCI14SOPL

1/4”

1381

MAL38CO

3/8”

12776

BCI38SOPL

3/8”

1382

1/2”

1383 1371

MAL12CO

1/2”

12777

BCI12SOPL

MAL34CO

3/4”

12778

BCI34SOPL

3/4”

MAL1CO

1”

12779

BCI1SOPL

1”

197665

MAL114CO

11/4”

12780

BCI2SOPL

2”

1388

MAL112CO

11/2”

12781

MAL2CO

2”

12782

Cored BCI12PL

1/2”

206693

MAL3CO

3”

12784

BCI34PL

3/4”

203284

BCI1PL

1”

1385

BCI114PL

11/4”

1373

BCI112PL

11/2”

1387

BCI2PL

2”

1375

BCI212PL

21/2”

BCI3PL

3”

Gas Equipment Catalog

Union MFR#

SIZE WEBB#

MAL18UN

1/8”

54291

MAL14UN

1/4”

30254

MAL38UN

3/8”

30255

MAL12UN

1/2”

30256

MAL34UN

3/4”

30257

MAL1UN

1”

30258

MAL114UN

11/4”

30259

MAL112UN

11/2”

30260

MAL2UN

2”

30261

MAL3UN

3”

30263

Tee MFR#

SIZE WEBB# 1/8”

1376

MAL18T MAL14T MAL38T MAL12T MAL34T MAL1T MAL114T MAL112T MAL2T MAL212T

1377

MAL3T

1/4” 3/8” 1/2” 3/4”

1” 11/4” 11/2” 2” 21/2” 3”

12586 12587 12588 12589 12590 12591 12592 12593 12594 12595 12596

victormfg.com


SECTION

7

Fittings

Black Malleable Fittings (continued) Reducing Tee SIZE WEBB# 12601 1/4” X 1/4” X 1/8” 12603 3/8” X 3/8” X 1/4” 12605 3/8” X 1/4” X 1/4” 12608 1/2” X 1/2” X 1” 12609 1/2” X 1/2” X 3/4” 12610 1/2” X 1/2” X 3/8” 12611 1/2” X 3/8” X 1/2” 12613 1/2” X 3/8” X 3/8” 12614 1/2” X 1/4” X 1/2” 12615 3/4” X 1/2” X 1/2” 12622 3/4” X 1/2” X 3/4” 12621 3/4” X 1/4” X 3/4” 12625 3/4” X 3/4” X 11/4” 12616 3/4” X 3/4” X 1/2” 12618 3/4” X 3/4” X 1/4” 12620 3/4” X 3/4” X 1” 12617 3/4” X 3/4” X 3/8” 12619 30252 1” X 1” X 1/2” 12627 1” X 1” X 11/2” 12628 1” X 1” X 11/4” 12631 1” X 1” X 3/8” 12632 1” X 1” X 1/4” 12633 1” X 3/4” X 1” 12634 1” X 3/4” X 3/4” 12635 1” X 3/4” X 1/2” 12636 1” X 1/2” X 1” 12637 1” X 1/2” X 3/4” 12638 1” X 1/2” X 1/2” 12639 1” X 1/4” X 1” 11/4” X 11/4” X 2” 12640 11/4” X 11/4” X 11/2” 12641 11/4” X 11/4” X 1” 12642 11/4” X 11/4” X 3/4” 12643 11/4” X 11/4” X 1/2” 12644 11/4” X 1” X 11/4” 12647 12648 11/4” X 1” X 1” 12649 11/4” X 1” X 3/4” 12650 11/4” X 1” X 1/2” 11/4” X 3/4” X 11/4” 12651 12652 11/4” X 3/4” X 1” 11/4” X 3/4” X 3/4” 12653 11/4” X 1/2” X 11/4” 12655 12656 11/4” X 1/2” X 1” 11/2” X 11/2” X 2” 12661 11/2” X 11/2” X 11/4” 12662 11/2” X 11/2” X 1” 12663 11/2” X 11/2” X 3/4” 12664 11/2” X 11/2” X 1/2” 12665 1/8” X 1/8” X 1/4”

MFR# MAL112X114X112T MAL112X114X114T MAL112X114X1T MAL112X114X34T MAL112X114X12T MAL112X1X112T MAL112X1X114T MAL112X1X1T MAL112X1X34T MAL112X34X112T MAL112X34X34T MAL112X12X112T MAL2X2X212T MAL2X2X112T MAL2X2X114T MAL2X2X1T MAL2X2X34T MAL2X2X12T MAL2X112X2T MAL2X112X112T MAL2X112X114T MAL2X112X1T MAL2X112X34T MAL2X114X2T MAL2X114X114T MAL2X1X2T MAL2X1X1T MAL2X34X2T MAL2X12X2T MAL212X212X2T MAL212X212X112T MAL212X212X114T MAL212X212X1T MAL212X212X34T MAL212X2X212T MAL212X2X2T MAL212X112X2T MAL3X3X212T MAL3X3X2T MAL3X3X112T MAL3X3X114T MAL3X3X1T MAL3X3X34T MAL3X212X2T MAL3X2X3T MAL3X2X2T

SIZE WEBB# 11/2” X 11/4” X 11/2” 12667 11/2” X 11/4” X 11/4” 12668 11/2” X 11/4” X 1” 12669 11/2” X 11/4” X 3/4” 12670 11/2” X 11/4” X 1/2” 12671 11/2” X 1” X 11/2” 12672 11/2” X 1” X 11/4” 12673 12674 11/2” X 1” X 1” 12675 11/2” X 1” X 3/4” 11/2” X 3/4” X 11/2” 12677 11/2” X 3/4” X 3/4” 12680 11/2” X 1/2” X 11/2” 12681 12684 2” X 2” X 21/2” 12685 2” X 2” X 11/2” 12686 2” X 2” X 11/4” 12687 2” X 2” X 1” 12688 2” X 2” X 3/4” 12689 2” X 2” X 1/2” 12690 2” X 11/2” X 2” 2” X 11/2” X 11/2” 12691 2” X 11/2” X 11/4” 12692 12693 2” X 11/2” X 1” 12694 2” X 11/2” X 3/4” 12695 2” X 11/4” X 2” 2” X 11/4” X 11/4” 12697 12699 2” X 1” X 2” 12702 2” X 1” X 1” 12704 2” X 3/4” X 2” 12706 2” X 1/2” X 2” 21/2” X 21/2” X 2” 12708 21/2” X 21/2” X 11/2” 12709 21/2” X 21/2” X 11/4” 12710 21/2” X 21/2” X 1” 12711 21/2” X 21/2” X 3/4” 12712 21/2” X 2” X 21/2” 12713 12714 21/2” X 2” X 2” 21/2” X 11/2” X 2” 12717 12719 3” X 3” X 21/2” 12720 3” X 3” X 2” 12721 3” X 3” X 11/2” 12722 3” X 3” X 11/4” 12723 3” X 3” X 1” 12724 3” X 3” X 3/4” 12727 3” X 21/2” X 2” 12729 3” X 2” X 3” 12730 3” X 2” X 2”

Reducing Coupling MFR# MAL14X18CO MAL38X14CO MAL38X18CO MAL12X38CO MAL12X14CO MAL12X18CO MAL34X12CO MAL34X38CO MAL34X14CO MAL34X18CO MAL1X34CO MAL1X12CO MAL1X38CO MAL1X14CO MAL114X1CO MAL114X34CO MAL114X12CO MAL114X38CO MAL112X114CO MAL112X1CO MAL112X34CO MAL112X12CO MAL2X112CO MAL2X114CO MAL2X1CO MAL2X34CO MAL2X12CO MAL212X2CO MAL212X112CO MAL212X114CO MAL212X1CO MAL3X212CO MAL3X2CO MAL3X112CO MAL3X114CO MAL3X1CO

SIZE WEBB# 12789 3/8” X 1/4” 12790 3/8” X 1/8” 12791 1/2” X 3/8” 12792 1/2” X 1/4” 12793 1/2” X 1/8” 12794 3/4” X 1/2” 12795 3/4” X 3/8” 12796 3/4” X 1/4” 12797 3/4” X 1/8” 12798 12799 1” X 3/4” 12800 1” X 1/2” 12801 1” X 3/8” 12802 1” X 1/4” 12803 11/4” X 1” 12804 11/4” X 3/4” 12805 11/4” X 1/2” 12806 11/4” X 3/8” 12808 11/2” X 11/4” 12809 11/2” X 1” 12810 11/2” X 3/4” 12811 11/2” X 1/2” 12813 2” X 11/2” 12814 2” X 11/4” 12815 2” X 1” 12816 2” X 3/4” 12817 2” X 1/2” 12818 21/2” X 2” 12819 21/2” X 11/2” 12820 21/2” X 11/4” 12821 21/2” X 1” 12822 3” X 21/2” 12823 3” X 2” 12824 3” X 11/2” 12825 3” X 11/4” 12826 3” X 1” 1/4” X 1/8”

Floor Flanges MFR# MAL12FLFLG MAL34FLFLG MAL1FLFLG MAL114FLFLG MAL112FLFLG MAL2FLFLG

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

SIZE WEBB# 12879 12880 1” 12881 11/4” 12882 11/2” 12883 2” 12884

1/2” 3/4”

141

7 gas pipe, tubing & fittings

MFR# MAL18X18X14T MAL14X14X18T MAL38X38X14T MAL38X14X14T MAL12X12X1T MAL12X12X34T MAL12X12X38T MAL12X38X12T MAL12X38X38T MAL12X14X12T MAL34X12X12T MAL34X12X34T MAL34X14X34T MAL34X34X114T MAL34X34X12T MAL34X34X14T MAL34X34X1T MAL34X34X38T MAL1X1X12T MAL1X1X112T MA1X1X114T MAL1X1X38T MAL1X1X14T MAL1X34X1T MAL1X34X34T MAL1X34X12T MAL1X12X1T MAL1X12X34T MAL1X12X12T MAL1X14X1T MAL114X114X2T MAL114X114X112T MAL114X114X1T MAL114X114X34T MAL114X114X12T MAL114X1X114T MAL114X1X1T MAL114X1X34T MAL114X1X12T MAL114X34X114T MAL114X34X1T MAL114X34X34T MAL114X12X114T MAL114X12X1T MAL112X112X2T MAL112X112X114T MAL112X112X1T MAL112X112X34T MAL112x112x12T

Reducing Tee (continued)


SECTION

7

Fittings Schedule 40 Nipples

1/8” — 1”

MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# 1/8” 1/4” 3/8” 1/2” 3/4” SIZE

MFR# WEBB# 1”

CLOSE NIP18XCLO

NIP1XCLO 14188

14121 NIP14XCLO 14132 NIP38XCLO 14143 NIP12XCLO 14154 NIP34XCLO 14171

1

NIP14X1

11/2

NIP18X112

14122 NIP14X112 14133 NIP38X112

90178 14144 NIP12X112 14155 NIP34X112

14172

14145 NIP12X2

14173

2

NIP18X2

14123 NIP14X2

21/2

NIP18X212

14124 NIP14X212 14135 NIP38X212 14146 NIP12X212 14157 NIP34X212 14174

14134 NIP38X2

NIP1X212

14190

3

NIP18X3

14125 NIP14X3

NIP1X3

14191

14136 NIP38X3

14147 NIP12X3

14156 NIP34X2 14158 NIP34X3

14175

NIP1X2

14189

31/2

NIP18X312

14126 NIP14X312 14137 NIP38X312 14148 NIP12X312 14159 NIP34X312 14176

NIP1X312

14192

4

NIP18X4

14127 NIP14X4

NIP1X4

14193

14138 NIP38X4

14149 NIP12X4

14160 NIP34X4

14177

41/2

NIP18X412

14128 NIP14X412 14139 NIP38X412 14150 NIP12X412 14161 NIP34X412 14178

NIP1X412

14194

5

NIP18X5

14129 NIP14X5

NIP1X5

14195

14140 NIP38X5

14151 NIP12X5

14162 NIP34X5

14179

51/2

NIP18X512

14130 NIP14X512 14141 NIP38X512 14152 NIP12X512 14163 NIP34X512 14180

NIP1X512

14196

6

NIP18X6

14131 NIP14X6

NIP1X6

14197

61/2

NIP12X612 90214 NIP34X612 86309

7

NIP18X7

NIP1X7

14198

71/2

NIP12X712 225065 NIP1X8

14199

NIP1X9

14200

NIP1X10

14201

110506 NIP14X7 89010 NIP14X8

14142 NIP38X6 93181 NIP38X7 90181 NIP38X8

14153 NIP12X6 67730 NIP12X7

14165 NIP34X7

14182

8

NIP18X8

9

NIP14X9

10

NIP18X10

90179 NIP38X10

79993 NIP12X10

14167 NIP34X9

14183

91/2

153238 NIP14X10

213167 NIP12X9

14166 NIP34X8

14181

81/2

86243 NIP38X9

110509 NIP12X8

14164 NIP34X6

14168 NIP34X10

14184 14185

101/2 11

NIP14X11 206628 NIP38X11

90199 NIP12X11

14169 NIP34X11

14186

NIP1X11

14202

90180 NIP38X12I 153004 NIP12X12

14170 NIP34X12

14187

NIP1X12

14203

14808

12

NIP14X12

13

14

15

16

17

171/2 18 19 20 21 22 24 26 27 28 30 36 40 42 43 48 53 54 60

NIP14X18 14776 NIP38X18 14784 NIP12X18 14792 NIP34X18 14800 NIP1X18

142

NIP34X20

90233

NIP14X24 14777 NIP38X24 14785 NIP12X24 14793 NIP34X24 14801

NIP1X24

NIP12X30 14794 NIP34X30 14802 NIP1X30 NIP14X36 14779 NIP12X36 14795 NIP34X36 14803 NIP1X36 NIP14X48 14781 NIP12X48 14797 NIP34X48 14805 NIP1X48 NIP12X60 14799 NIP34X60 14807 NIP1X60

Gas Equipment Catalog

14809

14810 14811

14813

14815

victormfg.com


SECTION

7

Fittings

Schedule 40 Nipples (continued)

11/4” — 3”

MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# 11/2” 2” 21/2” 3” SIZE 11/4”

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

14264

14265 14266 14267 14268 14269 14270 14271 14272 14273 14274 14275 14276 14277

67324

67325

67326 67327

143

7 gas pipe, tubing & fittings

LOSE NIP114XCLO 14204 NIP112XCLO 14219 NIP2XCLO C 14235 NIP212XCLO 14250 NIP3XCLO 1 2 NIP114X2 14205 NIP112X2 14220 21/2 NIP114X212 14206 NIP112X212 14221 NIP2X212 14236 3 NIP114X3 14207 NIP112X3 14222 NIP2X3 14237 NIP212X3 14251 NIP3X3 31/2 NIP114X312 14208 NIP112X312 14223 NIP2X312 14238 NIP212X312 14252 NIP3X312 4 NIP114X4 14209 NIP112X4 14224 NIP2X4 14239 NIP212X4 14253 NIP3X4 41/2 NIP114X412 14210 NIP112X412 14225 NIP2X412 14240 NIP212X412 14254 NIP3X412 5 NIP114X5 14211 NIP112X5 14226 NIP2X5 14241 NIP212X5 14255 NIP3X5 51/2 NIP114X512 14212 NIP112X512 14227 NIP2X512 14242 NIP212X512 14256 NIP3X512 6 NIP114X6 14213 NIP112X6 14228 NIP2X6 14243 NIP212X6 14257 NIP3X6 61/2 7 NIP114X7 14214 NIP112X7 14229 NIP2X7 14244 NIP212X7 14258 NIP3X7 71/2 8 NIP114X8 14215 NIP112X8 14230 NIP2X8 14245 NIP212X8 14259 NIP3X8 81/2 9 NIP114X9 14216 NIP112X9 14231 NIP2X9 14246 NIP212X9 14260 NIP3X9 91/2 10 NIP114X10 30269 NIP112X10 14232 NIP2X10 14247 NIP212X10 14261 NIP3X10 101/2 11 NIP114X11 14217 NIP112X11 14233 NIP2X11 14248 NIP212X11 14262 NIP3X11 12 NIP114X12 14218 NIP112X12 14234 NIP2X12 14249 NIP212X12 14263 NIP3X12 16 17 171/2 18 NIP114X18 14816 NIP112X18 14824 NIP2X18 14832 NIP212X18 67733 NIP3X18 21 22 24 NIP114X24 14817 NIP112X24 14825 NIP2X24 14833 NIP212X24 86476 NIP3X24 27 28 30 NIP114X30 14818 NIP112X30 14826 NIP2X30 14834 NIP212X30 200226 NIP3X30 36 NIP114X36 14819 NIP112X36 14827 NIP2X36 14835 NIP3X36 40 43 48 NIP114X48 14821 NIP112X48 14829 NIP2X48 14837 53 60 NIP114X60 14823 NIP2X60 14839


SECTION

7

Fittings Forged Steel Fittings, 3000# Socket Weld

45° Elbow

Tee

mfr# size

webb#

F/S12453SW

1/2”

8933

F/S34453SW

3/4”

8934

F/S1453SW

1”

8935

F/S114453SW

11/4”

8936

F/S112453SW

11/2”

8937

F/S2453SW

2”

8938

F/S212453SW

21/2”

8939

F/S3453SW

3”

8940

90° Elbow mfr# size

webb#

Reducer Coupling

mfr# size

webb#

1/2”

8945

F/S34T3SW

3/4”

8946

F/S12X38R3SW

1/2” X 3/8”

34915

F/S34X14CO3SW

3/4” X 1/4”

8986

86648

F/S1X12T3SW

1” X 1” X 1/2”

F/S114T3SW

11/4”

8948

F/S34X38R3SW

3/4” X 3/8”

34928

F/S112T3SW

11/2”

8949

F/S34X12R3SW

3/4” X 1/2”

34927

F/S2T3SW

2”

8950

F/S1X14CO3SW

1” X 1/4”

8991

F/S212T3SW

21/2”

8951

F/S1X38CO3SW

1” X 3/8”

8990

F/S3T3SW

3”

8952

F/S1X12R3SW

1” X 1/2”

34918

F/S1X34R3SW

1” X 3/4”

34919

F/S34X12T3SW

3/4” X 3/4” X 1/2”

177016

F/S112X1T3SW

11/2” X 11/2” X 1”

77863

F/S114X12R3SW

11/4” X 1/2”

34910

F/S2X1T3SW

2” X 2” X 1”

77864

F/S114X34R3SW

11/4” X 3/4”

34912

F/S2X112T3SW

2” X 11/2”

90134

F/S114X1R3SW

11/4” X 1”

34911

11/2” X 1/2”

34905

F/S1T3SW

1”

8947

F/S112X12R3SW

F/S112X34T3SW

11/2” X 11/2” X 3/4” 77862

F/S112X34R3SW

11/2” X 3/4”

34908

F/S112X1R3SW

11/2” X 1”

34906

8921

F/S34903SW

3/4”

8922

F/S1903SW

1”

8923

F/S114903SW

11/4”

8924

F/S112903SW

11/2”

8925

F/S2903SW

2”

8926

F/S212903SW

21/2”

8927

F/S12X14I3SW

1/2” X 1/4”

30641

F/S3903SW

3”

8928

F/S12X38ISW

1/2” X 3/8”

9050

F/S34X14I3SW

3/4” X 1/4”

9054

F/S34X38I3SW

3/4” X 3/8”

9053

F/S34X12I3SW

3/4” X 1/2”

9052

webb#

F/S12CA3SW

1/2”

9041

F/S34CA3SW

3/4”

9042

F/S1CA3SW

1”

9043

F/S114CA3SW

11/4”

9044

F/S112CA3SW

11/2”

9045

F/S2CA3SW

2”

9046

F/S212CA3SW

21/2”

F/S3CA3SW

3”

81754 9048

Cross

34914

F/S12T3SW

1/2”

mfr# size

webb#

1/2” X 1/4”

F/S12X14R3SW

F/S12903SW

Cap

mfr# size

F/S2X112T3SW

2” X 2” X 11/2”

90134

Insert mfr# size

webb#

F/S1X38I3SW

1” X 3/8”

9058

F/S1X12I3SW

1” X 1/2”

9057

F/S1X34I3SW

1” X 3/4”

9056

F/S114X12I3SW

11/4” X 1/2”

9063

F/S114X34I3SW

11/4” X 3/4”

30642

F/S114X1I3SW

11/4” X 1”

9061

F/S112X12I3SW

11/2” X 1/2”

9069

F/S112X34I3SW

11/2” X 3/4”

9068

F/S112X1I3SW

11/2” X 1”

9067

F/S112X114I3SW

11/2” X 11/4”

9066

F/S2X112I3SW

2” X 11/2”

9072

F/S2X114I3SW

2” X 11/4”

9073

F/S2X1I3SW

2” X 1”

9074

F/S2X34I3SW

2” X 3/4”

9075 9076

F/S112X114R3SW

11/2” X 11/4” 34903

F/S2X112R3SW

2” X 11/2”

34921

F/S2X114R3SW

2” X 11/4”

34922

F/S2X1R3SW

2” X 1”

9006

F/S2X34R3SW

2” X 3/4”

9007

F/S2X12R3SW

2” X 1/2”

9008

F/S212X2R3SW

21/2” X 2”

81774

F/S212X112R3SW

21/2” X 11/2” 202425

F/S212X114CO3SW 21/2” X 11/4” 200481

Union mfr# size

webb#

F/S12UN3SW

1/2”

9109

F/S34UN3SW

3/4”

9110

F/S1UN3SW

1”

9111

F/S114UN3SW

11/4”

9112

F/S112UN3SW

11/2”

9113

F/S2UN3SW

2”

9114

F/S212UN3SW

21/2”

9115

F/S3UN3SW

3”

9116

Reducing Elbow

F/S2X12I3SW

2” X 1/2”

F/S1CR3SW

1”

84306

F/S212X2I3SW

21/2” X 2”

200488

F/S34X12903SW

3/4” X 1/2”

172849

F/S2CRS3SW

2”

77868

F/S3X212I3SW

3” X 21/2”

69452

F/S1X12903SW

1” X 1/2”

172938

mfr# size

144

webb#

Gas Equipment Catalog

mfr# size

webb#

victormfg.com


SECTION

7

Fittings

Forged Steel Fittings

Flange Accessories

3000# Socket Weld

2H Nuts MFR#

Coupling

Half Coupling

mfr# size webb# F/S12CO3SW F/S34CO3SW F/S1CO3SW F/S114CO3SW F/S112CO3SW F/S2CO3SW F/S212CO3SW F/S3CO3SW

1/2” 3/4”

1” 11/4” 11/2” 2” 21/2” 3”

8957 8958 8959 8960 8961 8962 8963 8964

mfr# size webb# F/S12HCO3SW 1/2” F/S34HCO3SW 3/4” F/S1HCO3SW 1” F/S114HCO3SW 11/4” F/S112HCO3SW 11/2” F/S2HCO3SW 2” F/S212HCO3SW 21/2” F/S3HCO3SW 3”

8969 8970 8971 8972 8973 8974 8975 8976

Socket Welding Flanges Class 300

mfr# size webb# Threaded or Screwed Flanges W/F12300THDFLG 1/2” 27934 W/F34300THDFLG 3/4” 27935 W/F1300THDFLG 1” 27936 W/F114300THDFLG 11/4” 27937 W/F112300THDFLG 11/2” 73679 W/F2300THDFLG 2” 27939 W/F212300THDFLG 21/2” 27940 W/F3300THDFLG 3” 27941 W/F4300THDFLG 4” 27942 W/F6300THDFLG 6” 27943 Blind Flanges W/F12300BLFLG 1/2” 27944 W/F34300BLFLG 3/4” 27945 W/F1300BLFLG 1” 27946 W/F114300BLFLG 11/4” 27947 W/F112300BLFLG 11/2” 27948 W/F2300BLFLG 2” 27949 W/F212300BLFLG 21/2” 27950 W/F3300BLFLG 3” 27951 W/F4300BLFLG 4” 27952 W/F5300BLFLG 5” 27953 W/F6300BLFLG 6” 27954 W/F8300BLFLG 8” 27955 W/F10300BLFLG 10” 27956 W/F12I300BLFLG 12” 27957 Gaskets for SWG 300# Flange 1/2” 55404 3” 55411 3/4” 55405 4” 55413 1” 55406 5” 55414 55407 6” 55415 11/4” 55408 8” 55416 11/2” 2” 55409 10” 55417 55410 12” 55418 21/2”

size

Webb#

1/2”

119129 119130 119131 119132

5/8” 3/4” 7/8”

1”, 11/8” studs, available upon request.

B7 Studs MFR# hgr12x2b7 hgr12x214b7 hgr12x212b7 hgr12x234b7 hgr58x212b7 hgr58x234b7 hgr58x3b7 hgr58x314b7 hgr58x312b7 hgr58x375b7 hgr34x3b7 hgr34x314b7 hgr34x312b7 hgr34x334b7 hgr34x4b7 hgr34x414b7 hgr78x4b7 hgr78x434b7

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

size

Webb#

1/2” X 2”

119109 119110 119111 119112 119113 119114 119115 119116 119117 424777 119118 119119 119120 119121 119122 119123 119124 119126

1/2” X 21/4” 1/2” X 21/2” 1/2” X 23/4” 5/8” X 21/2” 5/8” X 23/4” 5/8” X 3” 5/8” X 31/4” 5/8” X 31/2” 5/8” X 33/4” 3/4” X 3” 3/4” X 31/4” 3/4” X 31/2” 3/4” X 33/4” 3/4” X 4” 3/4” X 41/4” 7/8” X 4” 7/8” X 43/4”

7 gas pipe, tubing & fittings

mfr# size webb# Weld Neck Flanges 27896 W/F12300WNFLG 1/2” 27897 W/F34300WNFLG 3/4” W/F1300WNFLG 1” 27898 W/F114300WNFLG 11/4” 27899 W/F112300WNFLG 11/2” 27900 W/F2300WNFLG 2” 27901 W/F212300WNFLG 21/2” 27902 W/F3300WNFLG 3” 27903 W/F4300WNFLG 4” 27904 W/F5300WNFLG 5” 27905 W/F6300WNFLG 6” 27906 W/F8300WNFLG 8” 27907 W/F10300WNFLG 10” 27908 W/F12I300WNFLG 12” 27909 Slip On Flanges 27915 W/F12300SOFLG 1/2” 27916 W/F34300SOFLG 3/4” W/F1300SOFLG 1” 27917 W/F114300SOFLG 11/4” 27918 W/F112300SOFLG 11/2” 27919 W/F2300SOFLG 2” 27920 W/F212300SOFLG 21/2” 27921 W/F3300SOFLG 3” 27922 W/F4300SOFLG 4” 27923 W/F5300SOFLG 5” 27924 W/F6300SOFLG 6” 27925 W/F8300SOFLG 8” 27926 W/F10300SOFLG 10” 27927 W/F12I300SOFLG 12” 27928 Gaskets for Manway 150# SWG160010008 16” 308728 SWG180010017 18” 202009 SWG200010017 20” 202010

HGR12NUT2H HGR58NUT2H HGR34NUT2H HGR78NUT2H

145


SECTION

7

Fittings Flange Size Chart for Stud/Bolt Length Pipe size 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3” 31/2” 4” 5” 6” 7” 10” 12” 14” 16” 18” 20” 22” 24” 26” 30” 34” 36” 42”

diameter of bolt circle 25/8” 31/4” 31/2” 37/8” 41/2” 5” 57/8” 65/8” 71/4” 77/8” 91/4” 105/8” 13” 151/4” 173/4” 201/4” 221/2” 243/4” 27” 291/4” 32” 341/2” 391/4” 431/2” 46” 523/4”

diameter of bolt 1/2” 5/8” 5/8” 5/8” 3/4” 5/8” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 1” 11/8” 11/8” 11/4” 11/4” 11/4” 11/2” 11/2” 15/8” 13/4” 17/8” 2” 2”

Forged Steel Fittings Threaded

45° Elbow mfr# size webb# 3000# F/S14453SE 1/4” 8700 3/8” 8689 F/S38903SE 1/2” 8702 F/S12453SE 3/4” 8703 F/S34453SE F/S1453SE 1” 8704 8705 F/S114453SE 11/4” 8706 F/S112453SE 11/2” F/S2453SE 2” 8707 F/S3453SE 3” 154532 2000# 1/4” 8665 F/S14452SE 8670 F/S114452SE 11/4” F/S3452SE 3” 8674

146

90° Elbow mfr# size webb# 3000# F/S14903SE 1/4” 8688 1/2” 8690 F/S12903SE 3/4” 8691 F/S34903SE F/S1903SE 1” 8692 8693 F/S114903SE 11/4” 8694 F/S112903SE 11/2” F/S2903SE 2” 8695 8696 F/S212903SE 21/2” F/S3903SE 3” 8697 2000# F/S14902SE 1/4” 8654 1/2” 8656 F/S12902SE F/S2902SE 2” 8661 3/4” 8657 F/S34902SE F/S1902SE 1” 8658 8659 F/S114902SE 11/4” 8660 F/S112902SE 11/2” F/S2902SE 2” 8661 8662 F/S212902SE 21/2” F/S3902SE 3” 8663

Gas Equipment Catalog

no. of bolts 4 4 4 4 4 8 8 8 8 8 8 12 12 16 16 20 20 24 24 24 24 28 28 28 32 36

length of stud

1/16” raised face

90° Street Elbow — 3000# F/S14S903SE 1/4” F/S38S903SE 3/8” F/S12S903SE 1/2” F/S34S903SE 3/4” F/S1S903SE 1” F/S114S903SE 11/4” F/S112S903SE 11/2” F/S2S903SE 2”

bolt length 2” 21/2” 21/2” 23/4” 3” 3” 31/4” 31/2” 33/4” 33/4” 4” 41/4” 43/4” 51/4” 53/4” 6” 61/2” 63/4” 7” 71/2” 73/4” 83/4” 10” 103/4” 111/4” 131/2”

21/2” 23/4” 3” 3” 31/2” 31/4” 33/4” 4” 41/4” 41/4” 41/2” 43/4” 51/4” 6” 61/2” 63/4” 71/4” 71/2” 8” 83/4” 9” 10” 111/4” 121/4” 123/4” 133/4”

8723 8724 8725 8726 8727 8728 8729 8730

Reducing Elbow mfr# size webb# 3000# F/S1X34903SE 1” X 3/4” 216219 F/S1X12903SE 1” X 1/2” 210687 F/S2X112903SE 2” X 11/2” 206543

Square Head Plug mfr# size webb# 3000# F/S14PL 1/4” 8828 3/8” 8829 F/S38PL 1/2” 8830 F/S12PL 3/4” 8831 F/S34PL F/S1PL 1” 8832 8833 F/S114PL 11/4” 8834 F/S112PL 11/2” F/S2PL 2” 8835 8836 F/S212PL 21/2” F/S3PL 3” 8837

Coupling mfr# size webb# 3000# F/S14CO3SE 1/4” 8732 8733 F/S38CO3SE 3/8” 8734 F/S12CO3SE 1/2” 8735 F/S34CO3SE 3/4” F/S1CO3SE 1” 8736 8737 F/S114CO3SE 11/4” 8738 F/S112CO3SE 11/2” F/S2CO3SE 2” 8739 8740 F/S212CO3SE 21/2” F/S3CO3SE 3” 8741

Cross

Cross mfr# size webb# 3000# F/S38CR3SE 3/8” 222407 180085 F/S12CR3SE 1/2” 187210 F/S34CR3SE 3/4” F/S1CR3SE 1” 110425 F/S114CR3SE 11/4” 200465 F/S112CR3SE 11/2” 184610 F/S2CR3SE 2” 223961 F/S3CR3SE 3” 187211

victormfg.com


SECTION

7

Fittings

Forged Steel Fittings – Threaded Bushing

mfr# size webb# 3000# F/S14T3SE 1/4” 8712 F/S38T3SE 3/8” 8713 F/S12T3SE 1/2” 8714 F/S34T3SE 3/4” 8715 F/S1T3SE 1” 8716 F/S114T3SE 11/4” 8717 F/S112T3SE 11/2” 8718 F/S2T3SE 2” 8719 F/S212T3SE 21/2” 8720 2000# F/S14T2SE 1/4” 8676 F/S38T2SE 3/8” 8677 F/S12T2SE 1/2” 8678 F/S34T2SE 3/4” 8679 F/S1T2SE 1” 8680 F/S114T2SE 11/4” 8681 F/S112T2SE 11/2” 8682 F/S2T2SE 2” 8683 F/S212T2SE 21/2” 8684 F/S3T2SE 3” 8685

Cap mfr# size webb# 3000# F/S14CA3SE 1/4” 8816 F/S38CA3SE 3/8” 8817 F/S12CA3SE 1/2” 8818 F/S34CA3SE 3/4” 8819 F/S1CA3SE 1” 8820 F/S114CA3SE 11/4” 8821 F/S112CA3SE 11/2” 8822 F/S2CA3SE 2” 8823 F/S212CA3SE 21/2” 8824 F/S3CA3SE 3” 8825

Reducer Coupling

Half Coupling

mfr# size webb# 3000# F/S14X18R3SE 1/4” X 1/8” 8755 F/S38X14R3SE 3/8” X 1/4” 8756 F/S38X18RED3SE 3/8” X 1/8” 8757 F/S12X14R3SE 1/2” X 1/4” 8759 F/S12X38R3SE 1/2” X 3/8” 8758 F/S34X14R3SE 3/4” X 1/4” 166093 F/S34X38R3SE 3/4” X 3/8” 8762 F/S34X12R3SE 3/4” X 1/2” 8761 F/S1X14RED3SE 1” X 1/4” 8768 F/S1X12R3SE 1” X 1/2” 8766 F/S1X34R3SE 1” X 3/4” 8765 F/S114X12R3SE 11/4” X 1/2” 34909 F/S114X34R3SE 11/4” X 3/4” 8771 F/S114X1R3SE 11/4” X 1” 8770 F/S112X12R3SE 11/2” X 1/2” 34904 F/S112X34R3SE 11/2” X 3/4” 34907 F/S112X1R3SE 11/2” X 1” 8776 F/S112X114R3SE 11/2” X 11/4” 8775 F/S2X12R3SE 2” X 1/2” 34923 F/S2X34R3SE 2” X 3/4” 34925 F/S2X1R3SE 2” X 1” 34924 F/S2X114R3SE 2” X 11/4” 8782 F/S2X112R3SE 2” X 11/2” 8781 F/S212X2R3SE 21/2” X 2” 81759 F/S212X112R3SE 21/2” X 11/2” 81756 F/S212X1R3SE 21/2” X 1” 209413 F/S3X212R3SE 3” X 21/2” 81764 F/S3X2R3SE 3” X 2” 155613 F/S3X112R3SE 3” X 11/2” 209415

mfr# size webb# 3000# F/S14HCO3SE 1/4” 8744 F/S38HCO3SE 3/8” 8745 F/S12HCO3SE 1/2” 8746 F/S34HCO3SE 3/4” 8747 F/S1HCO3SE 1” 8748 F/S114HCO3SE 11/4” 8749 F/S112HCO3SE 11/2” 8750 F/S2HCO3SE 2” 8751 F/S212HCO3SE 21/2” 8752 F/S3HCO3SE 3” 110427

Union mfr# size webb# 3000# F/S14UN3SE 1/4” 9096 F/S38UN3SE 3/8” 9097 F/S12UN3SE 1/2” 9098 F/S34UN3SE 3/4” 9099 F/S1UN3SE 1” 9100 F/S114UN3SE 11/4” 9101 F/S112UN3SE 11/2” 9102 F/S2UN3SE 2” 9103 F/S212UN3SE 21/2” 9104 F/S3UN3SE 3” 9105

Schedules 40 & 80 Black Pipe S40 Plain End

mfr# size webb# Plain End D/P14BPE 1/4” 179384 D/P38BPE 3/8” 79878 D/P12BPE 1/2” 45484 D/P34BPE 3/4” 45500 D/P1BPE 1” 45518 D/P114BPE 11/4” 45533 D/P112BPE 11/2” 45488 D/P2BPE 2” 45504 D/P212BPE 21/2” 45522 D/P3BPE 3” 45474 D/P4BPE 4” 45508

S40 Threaded

mfr# size webb# Threaded & Capped Ends D/P38BTC 3/8” 45473 D/P12BTC 1/2” 45490 D/P34BTC 3/4” 45507 D/P1BTC 1” 45524 D/P114BTC 11/4” 45477 D/P112BTC 11/2” 45493 D/P2BTC 2” 45511 D/P212BTC 21/2” 45527 D/P3BTC 3” 45480 D/P4BTC 4” 45514

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

S80 mfr# size webb# Plain End D/P14XHBPE 1/4” 45475 D/P12XHBPE 1/2” 45525 D/P34XHBPE 3/4” 45478 D/P1XHBPE 1” 45494 D/P114XHBPE 11/4” 45512 D/P112XHBPE 11/2” 45528 D/P2XHBPE 2” 45482 D/P212XHBPE 21/2” 45498 D/P3XHBPE 3” 45516 D/P4XHBPE 4” 45486

147

7 gas pipe, tubing & fittings

mfr# size webb# 3000# F/S14X18BU 1/4” X 1/8” 8851 F/S38X18BU 3/8” X 1/8” 8853 F/S38X14BU 3/8” X 1/4” 8852 F/S12X18BU 1/2” X 1/8” 8856 F/S12X14BU 1/2” X 1/4” 8855 F/S12X38BU 1/2” X 1/8” 8854 F/S34X18BU 3/4” X 1/8” 8860 F/S34X14BU 3/4” X 1/4” 8859 F/S34X38BU 3/4” X 3/8” 8858 F/S34X12BU 3/4” X 1/2” 8857 F/S1X18BU 1” X 1/8” 8865 F/S1X14BU 1” X 1/4” 8864 F/S1X38BU 1” X 1/8” 8863 F/S1X12BU 1” X 1/2” 8862 F/S1X34BU 1” X 3/4” 8861 F/S114X14BU 11/4” X 1/4” 8870 F/S114X38BU 11/4” X 3/8” 8869 F/S114X12BU 11/4” X 1/2” 8868 F/S114X34BU 11/4” X 3/4” 8867 F/S114X1BU 11/4” X 1” 8866 F/S112X14BU 11/2” X 1/4” 8877 F/S112X38BU 11/2” X 3/8” 8876 F/S112X12BU 11/2” X 1/2” 8875 F/S112X34BU 11/2” X 3/4” 8874 F/S112X1BU 11/2” X 1” 8873 F/S112X114BU 11/2” X 11/4” 8872 F/S2X14BU 2” X 1/4” 8885 F/S2X38BU 2” X 3/8” 8884 F/S2X12BU 2” X 1/2” 8883 F/S2X34BU 2” X 3/4” 8882 F/S2X1BU 2” X 1” 8881 F/S2X114BU 2” X 11/4” 8880 F/S2X112BU 2” X 11/2” 8879 F/S212X14BU 21/2” X 1/4” 8894 F/S212X34BU 21/2” X 3/4” 8891 F/S212X1BU 21/2” X 1” 8890 F/S212X114BU 21/2” X 11/4” 8889 F/S212X112BU 21/2” X 11/2” 8888 F/S212X2BU 21/2” X 2” 8887 F/S3X12BU 3” X 1/2” 8902 F/S3X1BU 3” X 1” 8900 F/S3X114BU 3” X 11/4” 8899 F/S3X112BU 3” X 11/2” 8898 F/S3X2BU 3” X 2” 8897 F/S3X212BU 3” X 21/2” 8896

Tee


SECTION

7

Fittings Schedule 80 Nipples MFR# webb# MFR# SIZE 1/4” CLOSE 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12

3/8”

1/4” - 1” webb# MFR#

1/2”

webb# MFR#

3/4”

webb# MFR#

1”

NIP14XCLOXH 14541 NIP38XCLOXH 14558 NIP12XCLOXH 14575 NIP34XCLOXH 14592 NIP1XCLOXH NIP14X112XH 14542 NIP38X112XH 14559 NIP12X112XH 14576 NIP34X112XH 14593 NIP14X2XH 14543 NIP38X2XH 14560 NIP12X2XH 14577 NIP34X2XH 14594 NIP1X2XH NIP14X212XH 14544 NIP38X212XH 14561 NIP12X212XH 14578 NIP34X212XH 14595 NIP1X212XH NIP14X3XH 14545 NIP38X3XH 14562 NIP12X3XH 14579 NIP34X3XH 14596 NIP1X3XH NIP14X312XH 14546 NIP38X312XH 14563 NIP12X312XH 14580 NIP34X312XH 14597 NIP1X312XH NIP14X4XH 14547 NIP38X4XH 14564 NIP12X4XH 14581 NIP34X4XH 14598 NIP1X4XH NIP14X412XH 14548 NIP38X412XH 14565 NIP12X412XH 14582 NIP34X412XH 14599 NIP1X412XH NIP14X5XH 14549 NIP38X5XH 14566 NIP12X5XH 14583 NIP34X5XH 14600 NIP1X5XH NIP14X512XH 14550 NIP38X512XH 14567 NIP12X512XH 14584 NIP34X512XH 14601 NIP1X512XH NIP14X6XH 14551 NIP38X6XH 14568 NIP12X6XH 14585 NIP34X6XH 14602 NIP1X6XH NIP34X7XH 14603 NIP34X8XH 14604 NIP1X8XH NIP34X10XH 203165 NIP34X12XH 203167 NIP1X12XH

webb# 14609 14610 14611 14612 14613 14614 14615 14616 14617 14618 14620

14624

11/4” - 3” MFR# webb# MFR# webb# SIZE 11/4” 11/2” CLOSE NIP114XCLOXH 14625 NIP112XCLOXH 14641 11/2 2 NIP114X2XH 14626 NIP112X2XH 14642 21/2 NIP114X212XH 14627 NIP112X212XH 14643 3 NIP114X3XH 14628 NIP112X3XH 14644 31/2 NIP114X312XH 14629 NIP112X312XH 14645 4 NIP114X4XH 14630 NIP112X4XH 14646 41/2 NIP114X412XH 14631 NIP112X412XH 14647 5 NIP114X5XH 14632 NIP112X5XH 14648 51/2 NIP114X512XH 14633 NIP112X512XH 14649 6 NIP114X6XH 14634 NIP112X6XH 14650 7 NIP114X7XH 14635 NIP112X7XH 225118 8 NIP114X8XH 14636 NIP112X8XH 14652 9 NIP114X9XH 225124 NIP112X9XH 223049 10 NIP114X10XH 187212 NIP112X10XH 223048 11 12 NIP114X12IXH 187213 NIP112X12XH 14656

MFR#

2” NIP2XCLOXH

NIP2X212XH NIP2X3XH NIP2X312XH NIP2X4XH NIP2X412XH NIP2X5XH NIP2X512XH NIP2X6XH NIP2X7XH NIP2X8XH NIP2X9XH NIP2X10XH NIP2X11XH NIP2X12XH

Concentric Swedge Nipples XH Mfr# NIPCS1X34XH NIPCS114X1XH NIPCS112X114XH NIPCS2X114XH NIPCS2X112XH NIPCS3X2XH NIPES2X112XH

148

2” X 11/2” Nipple Eccentric Swedge

21/2” 14657 NIP212XCLOXH

webb# MFR#

3” 14672 NIP3XCLOXH

14658 14659 NIP212X3XH 14673 14660 NIP212X312XH 14674 14661 NIP212X4XH 14675 14662 NIP212X412XH 14676 14663 NIP212X5XH 14677 14664 NIP212X512XH 14678 14665 NIP212X6XH 14679 14666 NIP212X7XH 210655 14667 NIP212X8XH 110508 187216 14669 187214 14671

NIP3X3XH NIP3X312XH NIP3X4XH NIP3X412XH NIP3X5XH NIP3X512XH NIP3X6XH NIP3X7XH NIP3X8XH NIP3X9XH NIP3X11XH NIP3X12XH

webb# 14686

14687 14688 14689 14690 14691 152712 14693 192822 192823 187218 187217 14699

XH Nipple Sets (1 of each)

Description webb# 187219 1” X 3/4” Nipple Concentric Swedge 187220 11/4” X 1” Nipple Concentric Swedge 11/2” X 11/4” Nipple Concentric Swedge 187221 187222 2” X 11/4” Nipple Concentric Swedge 187223 2” X 11/2” Nipple Concentric Swedge 3” X 2” Nipple Concentric Swedge 187224

Eccentric Swedge Nipples XH

webb# MFR#

190099

Gas Equipment Catalog

Mfr# NIP14XCLO-6XH NIP38XCLO-6XH NIP12XCLO-6XH NIP34XCLO-6XH NIP1XCLO-6XH NIP114XCLO-6XH NIP112XCLO-6XH NIP2XCLO-6XH

Description

webb# 73366 3/8” X CLOSE-6” Nipple Set Black XH 73367 1/2” X CLOSE-6” Nipple Set Black XH 52875 3/4” X CLOSE-6” Nipple Set Black XH 52876 1” X CLOSE-6” Nipple Set Black XH 52877 93049 11/4” X CLOSE-6” Nipple Set Black XH 93050 11/2” X CLOSE-6” Nipple Set Black XH 2” X CLOSE-6” Nipple Set Black XH 93051 1/4” X CLOSE-6” Nipple Set Black XH

victormfg.com


SECTION

8

Ignition Modules Gas Ignition Controls Universal Ignition Controls

780-001

Robertshaw’s Universal Ignition Control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application. 780-001 (Nonlockout) The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner. 780-002 (Lockout) These kits have a lockout feature to shut off all gas in the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides 3 tries for ignition, each ignition period is 90 seconds followed by a 6 minute time delay between ignition attempts. After 3 tries if no pilot flame is sensed, unit goes into lockout and must be reset at the thermostat. mfr# 780-001 780-002

description Non-Lockout Lockout

webb# 118693 75124

780 Series Hot Surface Ignition Module The 780 Series Hot Surface Ignition Modules are designed for use on gas fired heating systems The system acts on a demand for heat by a switch or thermostat to supply power to the ignition control. On non pre-purge models, the ignitor will be energized immediately and remain on for wither of two optional selected ignitor heat-up time approximately 17 or 34 seconds. For models with the prepurge option, there is a time delay equal to the heat-up time selected before the ignitor is energized. 780-785

mfr# 780-785 780-787

description Gas Ignition Control Gas Ignition Control

webb# 167059 246666

780-910 Universal Hot Surface Ignition Module Uni-Kit®

780-910

mfr# 780-910

description Universal Hot Surface Ignition Module

webb# 155174

Test Equipment 900-575 Module Tester

The 900-575 Test Kit is designed specifically for the professional service technician. Now an electronic ignition module — intermittent pilot, direct spark, hot surface can be quickly and accurately diagnosed at the job site. The 900-575 Tester will diagnose all the circuit functions on an I.C.U. Checking for proper sequence of operation and/or failure. No more guessing which part to replace. With the 900-575 change out the defective part the first time, not on a return call back. 900-575

mfr# description 900-575 Ignition Module Tester 720001W Quick Look Tester Q/L

webb# 152947 360275

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

149

8 Gas heating

The 780-910 Universal Hot Surface Ignition Module Uni-Kit is designed for use on gas fired systems. It is equipped with a self diagnostic green LED for quick troubleshooting. The LED indicates if the system is in normal operati on, has gone into lockout, has a weak flame signal, or has an internal error (a defective module).


SECTION

8

Ignition Modules

Replacement Controls and Components Ignition Control Units

780-735

780-015 Add-on lockout module. Using the 780-015 module with 780-715 module will give application lockout timing function for use on LP gas, 60 second timing lockout on pilot and main gas flow. 780-735 Lockout Model. Flame rectification system. Use with gas valves 7000 BDER and 7100 DER. Has 60 second lockout timing. 780-845 Universal lockout model has three 90 second valve trials interrupted by a six minute purge cycle before 100% lockout. mfr# 780-015 780-735 780-845

description Non-Lockout Flame Rectification System Lockout Flame Rectification System Gas Ignition Control

webb# — 73462 167191

Automatic Pilot Relight Kits The Robertshaw 785 Series automatic Pilot Relight Kits are designed for use on rooftop heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other commercial, industrial, and residential appliances where the problem of pilot outage may occur. It should only be applied to those systems which already incorporate the necessary pilot-safety control system. 785-001

mfr# 785-001

description Automatic Pilot Relight Kit

webb# 79497

Pilot Relite Control The relite control generates sparks until a pilot flame is sensed between the electrode and ground. When flame current is sensed between the electrode and pilot burner ground, the relite control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.

5059-23

ELECTRICAL mfr# INPUT VOLTAGE RATING 5059-23 24 Vac 0.03 Amps

description Spark Plug and 1/4� Spade Connectors

webb# 118717

Ignition Module for Hot Surface Ignition Systems The Hot Surface ignition Unit is a microprocessor based gas ignition control designed primarily for direct ignition and burner supervision applications such as gas furnaces, boilers, water heaters and other similar devices.

MFR#

50E47-150

50E41-843

Lockout time

Ignitor warm-up time

50E47 Prepurge time (in seconds)

Webb#

4 Seconds

45 Seconds

0 Seconds

152586

50E47-140 50E47-150

17 Seconds 7 Seconds

50E47-170

150

Gas Equipment Catalog

45 Seconds

30 Seconds 0 Seconds

192971 85263 152586

victormfg.com


SECTION

8

Ignition Modules Ignition Controls G600, G670

G600/G760 ignition controls are reliable, proven circuitry replacements for G60, G67 controls. In most cases the replacement controls have mounting configurations identical to the original device. Replacement controls feature precision timing for lockout models. Note: G600/G670 ignition control replacement parts must be used only for field replacement of existing equipment. These replacement parts must not be used for new field applications. MFR#

100% Lockout

G600AX-1C

remarks

Webb#

Yes

24 VAC, Terminal Bard Wiring

97579

No

24 VAC, 1/4” Spade Wiring Connections

105895

No

G670AW-1C

G600

damper plug

Universal Replacement Intermittent Pilot Ignition Control G779

The G779 Universal Replacement Intermittent Pilot ignition Control replaces many existing intermittent pilot controls made by various manufacturers. It is a safety control designed for indirect burner ignition and supervision. The G779 can be used with all gas-fired appliances with a maximum firing rate of 400,000 Btu/hr.

G779

Applications The G779 replaces existing intermittent pilot ignition controls with the following specifications: • Flame detection using flame rectification technology (ability of a flame to conduct and rectify current). • Integral or remote flame sensing. • Non-100% lockout, 100% lockout, or 100% shutoff with continuous retry. • Trial for ignition period greater than or equal to 25 seconds. • Prepurge period less than 1 second. • Pilot burners with flow rates of 1,500 Btu-hr or less. • Operating with or without vent dampers.

8 Gas heating

The G779 is not designed to replace ignition controls with the following specifications: • Pilot flame detection by any means other than flame rectification. • Trial for ignition period of less than 25 seconds. • Prepurge period greater than or equal to 1 second. • Standing pilot applications. Specifications Operating voltage Ignition source Prepurge Number of trials before 100% shutoff Trial time for ignition Retry delay period Flame failure response time Type of gas mfr# G779LHA-1C

24 VAC at 50/60 Hz High voltage spark, cap active discharge Less than one second One 25 Seconds 5 Minutes 0.8 Seconds Natural, Liquified Petroleum (LP), manufactured, mixed or LP gas-air mix

description webb# Universal Intermittent Pilot Ignition Control 110805

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

151


SECTION

8

Ignition Modules Spark Ignitor Q347

Produces spark for direct ignition of main burner. • Includes inner Kanthal electrode with ceramic insulator, bracket and Kanthal ground strap. • Use with S87C, D, K; S89E, F and Q354A. mfr# Rod Angle Q347A1004 Standard Orientation Q347

webb# 188456

Universal Intermittent Pilot Module S8610U

S8610U3009

Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances. • Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances. • Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. • For use in single rod of dual rod/remote sense applications. • Includes relay contacts for use with any intermittent pilot has control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended. Ignition Lockout Ignition Trials mfr# Description trial time timing to lockout webb# S8610U3009 Intermittent Pilot Control Continuous Retry 90 Sec. Max. Continuous Retry 74468

Universal Hot Surface Ignition Module S8910U

Provides operating control of a direct ignition system using a 120 Vac hot surface ignitor. • Provides easy field-replacement of a wide range of hot surface ignition modules manufactured by Honeywell, Robertshaw, and White-Rodgers. Refer to the product specifications sheet for specific models that can be replaced by the S8910U. • For 120 VAC (up to 5.0A) hot surface igniter (Norton 201/271 or equivalent). S8910U1000

The S8910U can be used only for direct replacement of specific installed models. Check the product specification sheet before replacing an existing hot surface module with the S8910U. If the existing module is not listed, do not use the S8910U to replace it. Always use the selection tab specified in the product specification sheet for the existing module being replaced. Replacement of an unlisted module or use of a selection tab other than specified can result in appliance malfunction. mfr# Description S8610U1000 Hot Surface Ignition Control

152

Gas Equipment Catalog

Ignition Lockout Ignition Trials trial time timing to lockout webb# 4 Sec. or 7 Sec. 4 Sec. or 7 Sec. 1 or 3 92054

victormfg.com


SECTION

8

Ignition Modules Gas Ignition Modules S89C Hot Surface Ignition Module

Provide electronic control of 120V hot surface ignition systems used in furnaces, boilers and other heating appliances. • S89C is for systems with combination ignitor-sensor. • Use with Norton 201 Hot Surface Ignitors or equivalent. • Lockout after one trial for igniting if main burner fails to ignite. • Reset from thermostat after lockout. mfr# S89C1087 S89C1095

S89C

Lockout timing ignition Trial TIme 6 Sec. 6 Sec. 15 Sec. 15 Sec.

webb# 95080 152200

Y8610U Universal Retrofit Intermittent Pilot Gas Burner ignition Systems Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 VAC gas-fired atmospheric furnaces, boiler and heating appliances. • Y8610U kits are for use with natural or LP gas; provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. • Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. MFR#

Y8610U Y8610U3003

Ignition sequence

typical gas control

Gas type

Webb#

Continuous Retry (after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place)

VR8304M Dual Valve Combination Gas Control

LP/Natural

74467

S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control

MFR#

S9200U1000

AMBIENT TEMP. (F) –40° F to +175° F

PREPURGE

HSI WARMUP TIME

30 seconds

17/27 or 30/30 seconds

HEAT HEAT POST- ON FAN OFF FAN PURGE DELAY DELAY 15 seconds

30 or 60 seconds

60, 90, 120, or 180 seconds

COOL FAN ON DELAY

5 seconds

COOL FAN OFF DELAY

GAS CONTROL USED WITH

Webb#

0 or 60 seconds

Any 24 VAC redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.

372843

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

153

8 Gas heating

S9200U1000

Controls a standard induction-type circulating fan motor. • Main burner ignition using a 120V hot surface igniter. • Flame rectification circuit to monitor flame presence. • Monitoring of system pressure switch, high temperature limit, and rollout functions. • Appliance operation/safety requirements controlled via microprocessor. • Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM™ thermostat. • LED system status, performance and diagnostic indication. • Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. • Twinning capability • EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.


SECTION

8

Gas Valves Water Heating

Domestic, Commercial & Recreational Vehicle Water Heater Thermostat Uni-Kits® 110 Series The 110-Series Water Heater Thermostat Uni-Kit® and Commercial Water Heater Thermostat Uni-Kit were designed for universal replacement applications. All models feature built-in, noncycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by inlet and outlet size, shank length, regulator type and setting. MFR#

Inlet Size

Outlet size

shank length

PresSure regulator setting

Webb#

13/8”

4.0” W.C. Natural Gas

85376

23/8”

3.5” W.C. Natural Gas

246749

13/8”

3.5” W.C. Natural Gas

73452

110-202 1/2” Pipe

110-206

1/2” Inverted Flare

110-326

110-202

Domestic and Commercial LP Gas Water Heater Thermostat Uni-Kits® The 110 Series Water Heater Uni-Kits® are designed for universal replacement applications. All models feature built-in, non-cycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by shank length. MFR#

Temp. Setting

INLET size

Outlet Size

Shank Length

PresSure regulator setting

Webb#

Right Hand Thread — Outlet: Replaces Model RPL 110-262

160º

1/2” Inverted

1/2” Pipe

Flare

Preset @ 10.0 (Adjustable from 9” W.C. - 12” W.C.)

13/8”

73449

Left Hand Thread — Outlet: Replaces Model R65RR 110-265

160º

110-285

180º

1/2” Pipe

1/2” Inverted Flare (Left hand Threads)

13/8”

Preset @ 10.0 (Adjustable from 9” W.C. - 12” W.C.)

11/2”

73450 75123

700 (70000GO) Commercial 700-800 Series bleed gas diaphragm valves feature: automatic pilot valve, bleed gas operator, inlet and outlet screens, manual “gas cock” valve, pilot adjusting key, pilot gas filter and pressure regulator (optional by model). Pressure Regulator Factory set at 3.5” W.C. MFR#

INLET size (FPT)

Outlet SizE (FPT)

PresSure regulator setting

Reducer bushings included (NPT) Capacity 3/4” x 1/2”

Webb#

700 “Thermopile” Type Diaphragm Gas Valves 700-885

3/4”

3/4”

None

305,000

2

186756

Gas Water Heater Controls For replacement of standard gas water heater controls with built-in E.C.O. (energy cut-off ). Features • Automatic shut-off of amin and pilot gas in the event of pilot failure. • Pilot gas cock with safe lighting feature. • Pilot gas filter. Specifications Inlet Size: 1/2” NPT Outlet Size: 1/2” Inverted Flare Mounting: 3/4” NPT, 11/4”, shank length, 41/2” bulb insertion length Pilot Connection: 1/2” compression fitting 37C63U-114 MFR# 37C63U-114

154

main burner

pilot

Temp. Range

shank length

Webb#

3.5” W.C.

Adjustable

70° F – 160º F

11/4”

188187

Gas Equipment Catalog

victormfg.com


SECTION

8

Gas Valves Boxed ICON Direct Replacement Gas Controls and Valves Can be utilized as a Direct Replacement on all Atmospheric Vent and Direct Vent Residential and Light Duty Bradford White ICON System™, Robertshaw or White Rodgers models up to 65 gallons* Includes: Pre-assembled ICON Gas Control Valve, Pilot Assembly, Feedline Spring, and Feedline adaptor. Residential Suffix Examples: Natural Gas (FBN, BN, LN, CN, EN) LP Gas (FSX, FCX, CX). Light Duty Commercial Suffix Examples: Natural Gas (FB-3N, B-3N, E3N) LP Gas (FS-3X, C-3X). mfr# description 239-47463-01 Res. (160°F) Direct Replacement Nat. ICON Gas Control Kit 1” Cavity 239-47465-01 Res. (160°F) Direct Replacement LP ICON Gas Control Kit 1” Cavity

webb# 420169 420168

Boxed ICON Universal Replacement Gas Controls and Valves Can be utilized as a Universal Replacement on all Atmospheric Vent and Direct Vent Residential and Light Duty Bradford White ICON System™, Robertshaw or White Rodgers models up to 65 gallons* Includes: Gas Control Cover, Gas Valve Body, 1” Thermowell, 2” Thermowell, 1” Insertion Stick, 2” Insertion Stick, Piezo Igniter, Temperature Sensor, Pilot Assembly, Feedline Spring, and Feedline adaptor. Residential Suffix Examples: Natural Gas (FBN, BN, LN, CN, EN) LP Gas (FSX, FCX, CX). Light Duty Commercial Suffix Examples: Natural Gas (FB-3N, B-3N, E3N) LP Gas (FS-3X, C-3X). mfr# description 239-47851-00 Res. (160°F) Universal Replacement Nat. ICON Gas Control Kit 1” & 2” Cavity 239-47856-00 Res. (160°F) Universal Replacement LP ICON Gas Control Kit 1” & 2” Cavity

webb# 420167 420166

Gas Oven Safeties

1720 (TS) “J” and “K” Magnet Heads

1720-801

mfr# 1720-801 1720-802

description Pilot Size Gas Oven Safety With Tubing Kit – “J” Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing Gas Oven Safety With Tubing Kit – “K” Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing

webb# 75107 85431

4020 (FMDA) with Pilot Inlet and Outlet The 4020 Safety Pilot Valves provide gas shutoff in case of pilot outage. When the reset button is depressed, gas will flow to the pilot only. Main gas will not flow until the pilot is operating and the reset button has been released. Pilot inlet and outlet connections are 1/2”tubing, unless otherwise indicated. 100,000 BTU/HR capacity. Ambient Temperature 32° – 350°F. 4020-010

MFR#

main burner

4020-010

48”

4020-011

54”

pilot 1/2” Pipe

Temp. Range

Webb#

11/64”

186656

15/64”

75110

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

155

8 Gas heating

The 1720 Series Replacement Magnet Kit is used with 1710 Series Bodies in TS Automatic Safety Valve applications. All models have FLOW INTERRUPTION so that no gas can flow to the main burner while the reset button is depressed. 1720 Series Kits are designed to replace many individual TS magnet types. Each magnet head kit is tapped for 1/8” pipe with fittings to adapt to 3/16” and 1/4” compression tubing. Also included: spring and diaphragm components, gasket and assembly screws.


SECTION

8

Gas Valves Gas Valves

Pilot, Direct and Hot Surface Ignition 700 Series These 700 Series Gas Valve Uni-Kits® are designed for intermittent pilot, direct spark and hot surface applications. They incorporate a manual valve, pilot valve, and main gas pressure regulator. Each Uni-Kit includes all the necessary parts and instructions needed to convert to direct spark or hot surface applications. OUTLET SIZE (FPT)

straight through

pressure regulator setting

MFR#

Inlet size (FPT)

700-056

3/4”

3/8”

3.5” Nat. Gas

350,000

85381

700-059

1”

1”

4.0” Nat. Gas

720,000

167052

capacity

Webb#

Universal Models Intermittent Pilot, Direct Spark & Hot Surface

700 Millivolt The 700 millivolt gas valves are wall thermostat actuated combination gas valves. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. The automatic pilot safety is separate from the gas cock and provides gas shutoff in case of pilot outage. Standard features include: pilot outlet, pilot gas filter and pilot adjusting key. Valves can be mounted in any position except upside down. MFR#

700-506

Inlet Straight size Through (FPT) (FPT)

side (FPT) w/ plugs

pressure regulator setting

3/4”

1/2”

capacity

1/2”

3/8”

Webb#

X

X

700-501

1/2”

1/2”

1/2”

None

100,000

2

192864

700-502

1/2”

1/2”

1/2”

3.5” W.C. Nat. Gas

100,000

2

186752

700-503

1/2”

3/4”

1/2”

None

240,000

1

94207

700-505

3/4”

3/4”

Straight-Thru

None

300,000

2

73457

700-506

3/4”

3/4”

Straight-Thru 3.5” W.C. Nat. Gas

300,000

2

73458

700-507

1/2”

3/4”

Straight-Thru 3.5” W.C. Nat. Gas

240,000

1

192865

300,000

2

193214

Pool Heater Models 700-511

3/4”

3/4”

Straight-Thru 3.5” W.C. Nat. Gas

700 Snap-Action and Snap-Throttle Hydraulic The 700-200 Series snap-action and snap-throttle (modulating) hydraulic controls are combination gas valves, thermostatically operated by a remote temperature sensing bulb. These controls combine a manual valve (gas cock), an automatic pilot safety valve, pressure regulator (optional by model) and a snap-acting or snap-throttle hydraulic operator for total temperature control. All models feature 3-position main gas outlets and pilot outlet, pilot gas filter, pilot adjustment key and automatic pilot valve.

700-201

MFR#

internal Inlet 3 Position pressure size outlet capillary regulator (FPT) (FPT) length setting

capacity

Reducer bushings included (NPT) 1/2” X 3/8”

Webb#

100,000

2

73454

Snap Action Models 700-201

1/2”

1/2”

36”

None

700-204

1/2”

1/2”

36”

None

160,000

2

73455

36”

3.5” W.C. Nat. Gas

100,000

2

85383

Snap Throttle Models

700-205

156

1/2”

1/2”

Gas Equipment Catalog

victormfg.com


SECTION

8

Gas Valves Gas Valves (continued)

700 24 Volt Combination Valve These valves feature a manual valve (gas cock), an automatic pilot safety valve, inlet/outlet screens, pilot outlet, pilot gas filter and pilot adjustment key. The automatic pilot safety valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.

MFR#

700-406

700-400 700-401 700-402 700-406 700-426 700-438 700-442

3 position outlet Inlet straight side (FPT) Pressure size thru with regulator (FPT) (FPT) plugs setting Snap Action Models 1/2” 3/4” Straight-Thru Uni-Kit 1/2” 3/4” 1/2” None 1/2” 3/4” 1/2” Uni-Kit 3/4” 3/4” 3/4” 3/4” Straight-Thru 3.5” W.C. 1” 1” Nat. Gas 1” 1”

capacity

Reducer bushings included (NPT) 3/4” X 1/2”

Webb#

240,000 240,000 240,000 300,000 300,000 720,000 720,000

1 1 1 2 2 — —

186748 79496 192862 73456 204405 — 103214

700 Diaphragm/Solenoid Valves These controls are single function, diaphragm types and are excellent replacements for solenoid gas valves. Standard features include: pilot outlet, pilot gas filter and pilot adjustment key. Valves can be mounted in any position except upside down.

MFR#

3 position outlet Inlet straight side (FPT) size thru with (FPT) (FPT) plugs

Pressure regulator setting

capacity

Reducer bushings included (NPT) 3/4” X 1/2”

Webb#

2 1 2

118694 204528 167053

24 Volt Diaphragm Models – Have No Safety Magnet 700-417 700-422 700-424

1/2”

3/4”

1/2”

3/4”

3/4”

3/4”

Straight-Thru 1/2” Straight-Thru

None 3.5” W.C. Nat. Gas

300,000 240,000 300,000

700 Line Voltage

capacity

Reducer bushings included (NPT) 3/4” X 1/2”

Webb#

240,000

1

186750

300,000

2

75115

3 position outlet MFR#

Inlet straight size thru (FPT) (FPT)

700-451

1/2”

3/4”

700-454

3/4”

3/4”

side (FPT) Pressure with regulator plugs setting 120 Volt Models 1/2” None 3.5” W.C. Straight-Thru Nat. Gas

705 Millivolt Operators The 705 Series millivolt operator kit is designed to allow field conversion of 700 & 710 Series manual gas valves to wall thermostat control. These operators are also replacements for specific 700-500 Series gas valves. MFR# 4020-010

block color 48”

pressure sensitive setting None

Webb# 192867

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

157

8 Gas heating

These controls combine into one compact valve: a manual gas cock, automatic pilot safety valve and a silent line voltage operator. The automatic pilot valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.


SECTION

8

Gas Valves Gas Valves (continued)

710 Low Profile Gas Heating Valves The 710 low capacity gas heating valves are designed for recreational vehicles and other applications with limited space. All models include a manual valve (gas cock), automatic pilot safety valve, pilot outlet, pilot gas filter and pilot adjusting key. The control can be mounted in any position except upside down and all models have 3-position outlets. MFR#

710-203

710-201 710-203 710-205 710-402 710-501

Inlet reducer pressure size 3 position bushings cap. regulator (FPT) outlet incl. (fpt) length setting Application Hydraulic Models — Snap Action 18” Recreational None Vehicles 1/2” 1/2” (2) 1/2” X 3/8” 36” 3.5” W.C. Wall Furnaces Nat. Gas Replaces TV-27 24 Volt Models 3.5” W.C. Wall Furnaces 1/2” 1/2” (2) 1/2” X 3/8” N/A Nat. Gas 12 VDC, 24 VAC Millivolt Models Note: Use two lead thermopliles only. Space Heaters 1/2” 1/2” (2) 1/2” X 3/8” N/A None Replaced B-67

Webb# 73459 85422 186764 186765 94208

720 Series Hot Surface Gas Valves The 720 Electronic Ignition Gas Valves are designed for a wide variety of heating applications. The valves incorporate a manual valve, dual automatic valves and a main gas regulator. Controls are multiposition and can be mounted in any position (except upside down). MFR#

720-079

720-051 720-079

side outlet pressure 1/2” fpt with regulator plugs setting capacity Standard Model 1/2” 3/4” Uni Kit 150,000 • Universal Model — Intermittent Pilot — Direct Spark — Hot Surface 1/2” 3/4” — Uni Kit 150,000

InleT size (FPT)

outlet size

Webb# 75113 90878

720 Series Dual Valve Gas Controls The 720 Series Dual Valve Gas Controls are designed for a wide variety of heating applications and can be used to replace most constant pilot valves, including dual valve (six function) models. The 720 Series constant pilot gas valve is a six function valve incorporating the manual valve, safety shutoff magnet, dual automatic valves (hence the term dual valves”), main gas regulator, and pilot adjustment. 720-406

MFR# 720-400 720-401 720-402 720-403 720-406 720-474

158

Inlet size (FPT) 1/2” 1/2” 1/2”

SIDE OUTLET pressure REDUCER BUSHINGS STRAIGHT 1/2” FPT regulator THRU WITH PLUGS setting CAPACITY 3/4” X 1/2” 1/2” X 3/8” • — Uni IG 1 — • • None 150,000 1 — • • 1 — 3/4” • • — 1 — Uni IG • — 150,000 2 — Standing Pilot Models — Stop Opening with Convertible Pressure Regulator 1/2” • • • 150,000 — 1

OUTlet size (FPT)

Gas Equipment Catalog

Webb# 167056 73460 167057 186770 73461 186771

victormfg.com


SECTION

8

Gas Valves Commercial Gas Thermostats 4200 (FD) Body Type #2 and Body Type #3 MFR# 4200-005

InleT INLET/ size OUTLET (FPT) SIZE #2 1/2” Pipe

PILOT Side

CAPILLARY MOUNTING LENGTH POSITION 48” 4-Way

BULB SIZE

3/16” X 143/4” Nickel

Webb# 186685

4200 (FD) Body Type #1

4200

MFR#

BODY TYPE

4200-025 Uni-IGI

#2

4200-026 Uni-IGI

#2

INLET INLET OUTLET OUTLET SIDE REAR SIDE SIDE PILOT CAPILLARY MOUNTING “f” “H” “E” “G” OUTLET LENGTH POSITION 150° to 550° F (Degrees) 3/8” 3/8” 3/8” 3/8” Side & 54” 4-Way Pipe Pipe Pipe Pipe Rear Low (200° F) to 550° F (Degrees) 3/8” Pipe

3/8” Pipe

3/8” Pipe

3/8” Pipe

Side & Rear

Kits

54”

4-Way

BULB SIZE

Webb#

3/16” Nickel

3/16” x 143/4”

186688

Nickel

®

712 Series Intermittent Pilot Ignition Uni-Kits

The Uni-Line 712 series pilot ignition system features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 series pilot ignition system features quick and easy installation with complete in-depth instructions and trouble shooting information.

Uni-Kit

MFR# 712-016

GAS IGNITION VALVE UNIT DESCRIPTION Nonlockout Models — Caution: Do not use on LP. Gas Applications 700-055 780-715 Natural Gas Only — Nonlockout Pressure regulator is 3/4” X 3/4” (Nonlockout) factory-set at 3.5” W.C. 350,000 Btu Max

Webb# 189792

Cycle-Pilot ® Retrofit Kit

Packages Available MFR# 21D18-3

GAS VALVES 38C84-426

FLAME SENSOR 3098-134

ELECTRODE ASSEMBLY 760-56

PILOT RELIGHT 5059-23

WIRING HARNESS F115-0084

Specifications MFR# 21D18-3

COIL VOLTAGE 60 Hz 24 VAC

ELECTRICAL RATING 0.61 amps

INLET/ OUTLET SIZE 3/4” X 3/4”

CAPACITY A.G.A. STANDARD GAS 280,000

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

GAS TYPE Natural Only

Webb# 188186

159

8 Gas heating

21D18-3

Control system designed to eliminate standing pilots by converting to cycle–pilot controls with automatic spark ignition. Gas valve functions are terminated on a printed circuit board that exits through the mercury flame sensor receptacle housing, on the terminal panel side. Features • Eliminates gas wasted by a standing pilot. • Eliminates pilot outage problems due to occasional drafts. • Each package contains the controls and hardware needed for conversion to cycling pilot operation. • Uses existing pilot burner and wiring.


SECTION

8

Gas Valves SmartValve™ System SV9501

Combines gas flow control and electronic intermittent pilot sequencing functions into a single unit. • Suitable for a wide range of gas-fired appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units • Replaces SV9500, SV9501 and SV9502 control. See installation instructions for specific models. Ignition sequence includes timed trial for ignition. SV9501

MFR# SV9501M2528 SV9502H2522 SV9602P4816

TEMPERATURE size RATINGS 1/2” -40° F To 175° F 1/2” -40° F To 175° F 3/4” -40° F To 175° F

Accessories Q3400A1024 39369

PRESSURE REGULATOR SETTING 3.5” W.C. 3.2” W.C. 3.5” W.C.

PrePurge None 15 Sec. 30 Sec.

OPENING CHARACTERISTICS Standard Opening Slow Opening Step Opening

Ignitors Natural to LP Conversion Kit

Webb# 210277 214000 424578

154343 184601

Gas Valves,Electronic Single Stage — Standing Pilot V800 Low Voltage Combination Gas Controls

Provide complete control of continuous pilot gas-fired central furnaces and boilers. • Include pilot flow adjustment screw. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence.

V800

MFR# V800A1070 V800A1088

TYPE OF GAS

PRESSURE REGULATOR SETTING

Natural Or LP

3.5” W.C.

INLET/ OUTLET SIZE 3/4” X 3/4” 1/2” X 3/4”

INCLUDES One 3/4” X 1/2” Reducer Bushings/Adapters Two 3/4” X 1/2”, One 1/2” X 3/8” Reducer Bushings/Adapters

Webb# 35054 35055

VR8200 Continuous Pilot Dual Automatic Valve Combination Gas Controls

VR8200

MFR# VR8200A2132

160

TYPE OF GAS Natural

Combination gas controls for use in 24 VAC gas-fired, standing pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. LITE-RITE (OFF-PILOT-ON) lighting sequence. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. PRESSURE REGULATOR SETTING 3.5” W.C.

INLET/OUTLET SIZE 1/2” X 1/2”

Gas Equipment Catalog

OPENING CHARACTERISTICS Standard

INCLUDES

Webb#

1/2” X 3/8” Reducer Bushings; 38389014 bag assembly - 3/4” straight flange with O ring screws and wrench; and 393891 Natural to LP Gas Conversion Kit

68950

victormfg.com


SECTION

8

Gas Valves Gas Valves, Electronic Single Stage — Standing Pilot

VR8300 Continuous Pilot Dual Automatic Valve Combination Gas Control

VR8300

Combination gas control for use in 24 VAC gas-fired standing pilot appliances with capacities from 30 to 300 cfh. • Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. • LITE-RITE (OFF-PILOT-ON) lighting sequence. MFR# VR8300A4516

PRESSURE INLET/ REGULATOR OUTLET SETTING SIZE 3.5” w.c.

3/4” X 3/4”

INCLUDES Two 3/4” X 1/2” Reducer Bushings; 383200EOO adapter, Q340 (36”) thermocouple with adapters, 393691 Natural to LP Gas Conversion Kit

Webb# 86743

Gas Valves, Electronic Single Stage — Intermittent Pilot

VR8204 Intermittent Pilot Dual Automatic Valve Combination Gas Controls

VR8204 MFR# VR8204A2076

PRESSURE INLET/ OPENING TEMPERATURE REGULATOR OUTLET CHARACTERRATINGS SETTING SIZE ISTICS -18° F to +79° F

3.5” w.c.

1/2” X 1/2”

Standard

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

INCLUDES

Webb#

Bushing 393691 Natural to LP Gas Conversion Kit

76221

3/4” X 3/8” Reducer

161

8 Gas heating

Combination gas control for use in 24 VAC gas-fired intermitent pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Use with S86F,H; S8600F,H and S8610 Control Modules. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • ON-OFF lighting sequence.


SECTION

8

Gas Valves Gas Valves, Electronic Single Stage— Direct Ignition VR8345 Universal Electronic Ignition Combination Gas Control

VR8345

Universal electronic ignition combination gas control for use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 VAC, gas-fired appliances, with capacities from 30 to 415 cfh. • Control includes manual valve, two automatic operators, pressure regular, pilot adjustment, pilot plug and ignition adapter. • Replaces virtually any IP, HSI, or DSI gas control. • For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas. • Compact size. • All adjustments and wiring connections accessible from top of control. • Four-inch swing radius allows easy rotation into position inside the tightest furnace vestibules. • Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/ HSI jumper. • Internal inlet screen blocks contaminants in gas line from entering valve.

MFR#

INLET/ OUTLET SIZE

PRESSURE REGULATOR SETTING

TYPE OF GAS

VR8345M4302

3/4” X 3/4”

3.5” w.c.

Natural

INCLUDES Two 3/4” X 1/2” NPT Reducer Bushings and one 1/2” X 3/4” NPT Bushing

Webb# 93587

Gas Valves, Millivolt

VS830 Millivoltage Combination Gas Controls

VS830

Provide complete control of continuous pilot gas-fired central furnaces and boilers. • Include pilot flow adjustment screw. • Easy to install, adjust and service; all adjustments and connections are accessible from top of control. • Add separate energy cutoff (ECO) where codes call for dual safety shutoff. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence. • ECO connector for V800 models. Part No. 392451-1. MFR#

162

INLET/OUTLET SIZE

VR820A1047

1/2” X 3/4”

VR820A1054

3/4” X 3/4”

Gas Equipment Catalog

PRESSURE REGULATOR SETTING

TYPE OF GAS

3.5” w.c.

Natural

Webb# 35056 35057

victormfg.com


SECTION

8

Thermocouple & Thermopile Generators

Thermocouples and Pilots 1950 & 1951 Thermopiles

The 1950 and 1951 Thermopiles (pilot generators) are designed for use on self-positioned gas control systems.

Mfr# 1950-001 1950-002 1950-003 1950-532 1950-548 1951-001 1951-536

Includes PG9 Connection Length Pilot Adapter Webb# Type 36” 48” 60” 36” 48” 36” 36”

• • • — — • —

Two Lead

Coaxial

82642 194065 186640 192848 186641 73469 111602

1970 Uni-Couples 20 to 30 Millivolts The 1970 Series Uni-Couples unique design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermocouple’s rolled threads for proper positioning in every application. The stainless steel tip (longer life), extended cold junction (greater voltage output potential), copper tube (corrosion protection with low electrical resistance), and lock washer equipped coaxial connection (resists loosening due to vibration or changes in ambient temperature) make the Uni-Couple the single most versatile thermocouple available today. LENGTH 18” 24” 30” 36” 48” 60” 72”

webb# 167188 167189 167190 85375 155170 186644 85441

1980 Snap-Fit Thermocouples The 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. Both slim and standard thermocouple types are available in the 1980 Series without complicated adapters, but with the extra insulation from high ambient temperatures that the brass sheath offers when needed. The 1980 is constructed of the same materials as used in the 1970. mfr# 1980-018 1980-024 1980-030 1980-036 1980-048 1980-060 1980-072

LENGTH 18” 24” 30” 36” 48” 60” 72”

The 1960-027 is a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. Also found on many L.P. gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame. Note: Has standard thermocouple threads. Will not fit applications with metric threads. mfr# 1960-027

LENGTH 27”

webb# 217093

Replacement Parts Thermocouple Test Adapter

Adapter to test thermocouple and thermopile closed circuit. mfr# Description 10-238 Thermocouple Test Adapter

webb# 167043

Shank Extension Increases length of 11/4” and 13/8” shank models to approximately 3”. mfr# Description 10-250 Shank Extension

webb# 80696

Junction Block Adapter The 1922-001 adapter allows the high limit switch to be connected into the thermocouple cicuit on valves without the slotted magnet. mfr# Description 1922-001 Junction Box Adapter Y99AN-1H Junction Block Adapter

webb# 75109 178174

1922-001

webb# 73470 73471 186645 73472 152596 73473 188181

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

8 Gas heating

mfr# 1970-018 1970-024 1970-030 1970-036 1970-048 1970-060 1970-072

1960-027 Low Mass Thermocouple

Y99AN-1H

163


SECTION

8

Thermocouples & Thermopile Generators

K15 Series

The K15 Series Thermocouples are designed for use in standing pilot ignition systems. They are used primarily with BASO brand automatic pilot controls and pilot burners. K15DS models are standard thermocouples. K15FS models are snap-on thermocouples that allow for fast, easy assembly. The K15WS model is a wholesale thermocouple that is supplied with additional fittings. Mfr# K15DS-18H K15DS-24H K15DS-30H K15DS-36H K15FS-24H K15FS-36H K15WS-48H

Length(IN) 18 24 30 36 24 36 48

TYPE Standard BASO

Snap in BASO Standard BASO With Fittings

Webb# 184577 183556 183557 184579 183561 183562 183563

“Husky” High Performance Thermocouple K16 Series

The K16 Series are heavy-duty, high performance thermocouples that provide high output for residential, commercial, and industrial applications. The “Husky” is a replacement for BASO 17D, 50, 58D, 87D, 88D, 97D, 107D, and K15DA thermocouples. The K16 is packed with adapters to allow the necessary replacement. K16BT models are standard thermocouples. K16RA models are nickel plated thermocouples. K16WT models are wholesale thermocouples that are supplied with additional fittings. Mfr# K16BT-18H K16BT-24H K16BT-30H K16BT-36H K16RA-60C K16WT-48H

164

“Super Slim Jim™” Universal Replacement Thermocouples

Standard BASO® Thermocouple

Length (IN) 18 24 30 36 60 48

TYPE “Husky”

“Husky” Nickel Plated “Husky” With Fittings

Webb# 183564 152511 183565 96960 194088 183568

Gas Equipment Catalog

Mfr#

Length (IN)

K19AT-18H K19AT-24H K19AT-30H K19AT-36H K19AT-48H K19AT-60H

TYPE

18 24 30 36 48 60

Webb#

“Super Slim Jim”

183569 183570 183571 152513 155142 183574

Replacement Thermopile Generators Q313

Provide power for millivoltage, self-powered control systems. • Eliminate the need for outside power source. • Easy push-in installation. • Include spade terminals. • Individually skin packed, each unit ordered represents one thermopile generator. Mfr#

Lead Length Resistance

includes 1/2” thermopile

Webb#

attaching nut

188174

Q313A1139

Push-in clip

83335

Q313A1170

PG9 adapter (part #393948)

85874

Q313A1188

1/2” thermopile

Q313A1055

47”

2.90 ohm

35”

2.89 ohm

Q313B1005

Push-in clip,

attaching nut Includes junction box for series hook up with high limit switch

84659 86741

Universal 30 mV Thermocouple Q340

There is a Q340 for every gas-fired heating system application. • Replace almost any 30 mV thermocouple. • Average operating life of ten years. • Available in a variety of lead lengths. Mfr# Q340A1066 Q340A1074 Q340A1082 Q340A1090 Q340A1108

Length (IN) Webb# 18” 24” 30” 36” 48”

30876 30877 30878 30879 86216

victormfg.com


SECTION

8

Pilot Burner & Orifices

Anderson & Forrester Inc.

Gauging Drill Kit — GDK4080 Plastic box contains 41 drill sizes: #40 – 80, and GB3020H tapered broach. MFR# Description Webb# ANFGDK4080 Gauging Drill Kit 188739

Tapered Broach — GB3015 Gauging Drill Kit Tapered Broach

Three cornered broach. Tapered from .003” to .013”. A must for cleaning Pilot Orifices. MFR# Description Webb# ANFGB3015 Three Cornered Broach 180504

Gauging Reamer Kit — GRK5000 Have the correct size reamer when you need it. Our kit contains each size in a slim plastic case.

Gauging Reamer Kit

MFR# Description Webb# ANFGRK5000 Gauging Reamer Kit 180593 ANFGR5070 Gauging Reamer, #70, 5 Pack 180602 ANFGR5080 Gauging Reamer, #80 180598

Master Adapter Kit — MIK100 Includes all tools needed to assemble MI100 adapters.

Master Adapter Kit

MFR# Description Webb# ANFMIK100 Master Adapter Kit 180533 ANFMI100 Universal Adapter 180532

Serviceman’s Orifice Assortment Kit — MIK131LP The MIK131 orifice cabinet contains 23 of those orifices most commonly used. Over 300 orifices in proportion to normal demand. MFR# Description Webb# ANFMIK131LP Orifice Assortment 188738

8

Master Pilot Orifice Assortment Kit — MIK132LP In one kit you now have 32 of the most needed pilot orifices with over 100 pieces. These are replacement pilot orifices for Penn Baso, Robertshaw, General Controls, Honeywell and White-Rodgers. A must for every efficient serviceman. Cabinet is made of heavy gauge steel with durable baked enamel finish and radius bottom sections for easy removal. MFR# Description Webb# ANFMI132LP Pilot Orifice Assortment Kit 180534 Master Orifice Kit

Serviceman’s Friend — TL051 For use with flow meter and other applications. One end of fitting has 1/8” pipe thread, 1/4” pipe thread and special 5/16” X 32 thread. Opposite end has regular hose fitting, also 1/8” straight pipe thread. Hose can be used on either end. Serviceman’s Friend

MFR# Description Webb# ANFTL051 Serviceman’s Friend 180578

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

165

Gas heating

Serviceman’s Orifice Kit


SECTION

8

Pilot Burner & Orifices

Replacement Parts & Accessories

Gas Orifices & Gauging Drills (continued)

Pilot Tube Compression Fittings

Just bend and cut to length! Keep a few on your truck to take care of clogged pilots! 3/16” pilot tube, 17” long with 4 port orifice hood.

Break-away type separates upon tightening.

Mfr# 10-383 MFR# Description Webb# 1/8” Short Breakaway Nut 180414 ANFCF639 3/16” Short Breakaway Nut 180415 ANFCF640 1/4” Short Breakaway Nut 180388 ANFCF641 102371 HON386449-1 1/4” Breakaway Nut 1/4” Medium Breakaway Nut 180599 ANFCF642 181653 EMPR1633-2 1/8” Long Breakaway Nut 223431 HON386449-4 1/4” Long Breakaway Nut 1/4” Long Breakaway Nut EMPR2972 EMPR1633-4-2 1/4” X 1/8” Long Breakaway Nut

RBS4590-065 RBS4590-067 RBS4590-069 RBS4590-071 RBS4590-072

1/8” Short Breakaway Nut

3/16” Short Breakaway Nut 1/4” Short Breakaway Nut 3/8” Short Breakaway Nut

7/16” Short Breakaway Nut

181654 181653 93031 93030 93028 186719 189070

Orifice Caps mfr# Description ANFCO400-72 LP, 1/2” Hex, 3/8-40 UNS ANFCO401 Blank, 1/2” Hex, 1/2-27 NPT ANFCO403 Bored, 1/2” Hex, 3/8-27 UNS ANFCO404 Blank, 9/16” Hex, 1/2-27 UNS ANFCO406 Blank, 1/2” Hex, 3/8-27 UNS

webb# 180416 180419 180421 180422 180424

Anderson & Forrester Inc. Orifice Hex Plugs

mfr# Description webb# 180541 ANFPO505 Blank, 1/2” Hex, 1/8-27 NPT 180544 ANFPO508 Blank, 1/4” Hex, 1/4-28 UNF 180546 ANFPO511 Blank, 1/2” Hex, 7/16-27 UNS ANFPO518 Blank, 3/8” Round, 11/32-32 Special 180549

166

Gas Equipment Catalog

description 3/16” X 17” Pilot Tube

webb# 189026

Aluminum Tubing A full range of diameter sizes in 50’ lengths, and for convenience, 5’ lengths with fittings. Mfr# O.D. Size

Length webb#

11-016

7/16”

5’

94204

11-017

3/8”

5’

155172

11-191

1/8”

50’

153380

11-193

1/4”

50’

155171

11-195

3/8”

50’

155173

11-291

1/8”

5’

212789

11-292

3/16”

5’

73442

11-293

1/4”

5’

73443

Pilot Orifices mfr# Gas Type tube size orifice size webb# 1/4” or 3/16” .010 186598 10-030 LP 1/4” .0088 186605 10-261 LP Pilot gas mfr# usage type

tube orifice size size webb#

10-066 #70 & #71 10-043 #70 & #71 10-045 #40A

3/16”

Nat. Nat. & L.P. L.P.

10-028

3/16” 3/16”

.018 .014 .013

— 85387 186600

10-261

10-043 10-045 10-066

victormfg.com


SECTION

8

Pilot Burner & Orifices Pilot Burner Q314

Nonprimary-aerated, insert orifice type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation. • Use with Q313 Thermopile Generator for 750 mV powerpile applications. Mfr#

Q314

Q314A4586 Q314A6094 Q314A4585

TYPE OF GAS

MOUNTING BRACKET

DIRECTION OF FRONT TIP

Webb#

B

Front Left Right

80635 86742 —

LP; Natural

Q327 Primary-aerated, spud orifice-type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation. • Use with Q313 Thermopile Generator for 750 mV powerpile applications. MFR# Q327A1626

Q347

Description

Type of gas

Webb#

Bat Wing

LP; Natural

88371

Q345 Nonprimary-aerated, combination pilot burner and ignitor. Used with the S86, S8610, or S8670 in intermittent pilot systems. • Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark ignitor and ground strap. Mfr#

Direction of front tip

Q345A1305 Q345A1313

TYPE OF GAS Webb#

Front Left

152195 152196

Natural

Q345A

Combination Type Pilot Burner The J991MDA-2 through J999MDA-2 models are universal replacement pilot burners for J10(-)DDA, J11(-)DDA (D10and D11) types. The pilot burners are individually packaged in a plastic bag. 10 bags per carton. Mfr# J992MDA-2H J997MDA-2H J998MDA-2H J999MDA-2H

2 7 8 9

LP GAS ORIFICE

Webb#

Y90AA-4213 Y90AA-4211 Y90AA-4212 Y90AA-4212

183617 118696 118697 183554

Y90AA-3223 Y90AA-3221 Y90AA-3223 Y90AA-3223

Multi-Mount Universal Pilot Burner #8

J999MHA-2

#9

J999MKA-2

The J Series BASO universal replacement pilot burners are supplied in three models. Mounting brackets on all four sides of each burner permit adaptation to almost any application. The pilot burners are individually packed in a plastic bag. 10 bags per carton. • Three tapped holes in each bracket for vertical adjustment. • Natural and LP gas orifice supplied. • Nuts and bolts furnished in each package. Mfr#

J999MYA-2

J999MHA-2H J999MKA-2H J999MYA-211

TYPE OF PILOT NATURAL GAS ORIFICE LP GAS ORIFICE “L” Channel Shell “Y” Channel

Y90AA-7223 Y90AA-7221 Y90AA-6221

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Y90AA-4211 Y90AA-4210 Y90AA-4211

8 Gas heating

#2

#7

TIP POSITION NATURAL GAS ORIFICE

Webb# — 118699 183620

167


SECTION

8

Pilot Burner & Orifices Pilot Kits

1810-100 Universal 2BLC Pilot Uni-Kit®

1830-700 Pilot Electrode Series

The 1810-100 Universal 2 BLC Pilot Uni-Kit is designed to replace the obsolete Model 2B/2BLC Pilot which is no longer in production. The kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. Each kit comes with a Natural gas orifice installed and includes a separate L.P. gas orifice.

The 1830-700 Series Pilot Uni-Kits are designed for use with the O.E.M. style Pilot Ignition Systems. The electrode is permanently riveted to the pilot frame and the spark gap is fixed at 1/8”. These pilots can be used to replace existing pilot assemblies or when retrofitting standing pilot applications when and exact replacement is desired. Each Uni-Kit comes with a natural gas orifice installed and a separate L.P. gas orifice. Pilot tubing size is 1/4”.

mfr# description 1810-100 Universal Pilot Uni-Kit

MFR# 1890-705

webb# 87067

Flame pattern type Standard

lead length 24”

1820 Series PG9 Replacement Pilot Uni-Kits®

1850/1851 Mini Pilot 100’s

The 1820 Series UniKits are designed to replace those hard-to-find ITT-General PG9 type pilots. Each Uni-Kit come with a natrual gas orifice installed and a separate L.P. gas orifice. A special 1/4” tubing adapter is provided that allows use of original tubing with nut and ball sleeve.

Mini-Pilot 100’s are nonaerated (no primary air) and can be used on all gases with no orifice change. The pilots are positionsensitive and care should be taken to install them in their correct position. (TOP stamped into casting at top when applied).

Flame pattern MFR# (Degrees) 1820-009 90 Right 1820-019

90 Left

1820-029

90 Right

1820-039

90 Left

type of gas Natural and L.P. Gas Orificies Included

MFR#

with thermopile •

Webb# 186617

186618

Pilot Only

75116 —

1830 (2CH & 2C) Incinerator-Target Pilot Uni-Kits® The 1930 Series Pilot Uni-Kit is designed to be used with all Uni-Line and competithive thermocouples. Kits include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type model 2C. Each kit comes with a natural gas orifice installed, and a separate L.P. gas orifice. Hood MFR# type 1830-001 2 1830-002 1830-003 1830-004 1830-005 1830-011

5

mounting bracket type

6

2 4

flame pattern type Standard

Webb# 75118

90 Degrees Left

111048

90 Degrees Right

166784

25 Degrees Left

189032

3-Way (A)

111049

4

3-Way (C)

85399

1830-013

5

7

90 Degrees Left

152595

1830-015

3

4

1830-210

2

1830-213

4

1830-489

6

168

2 6

Standard

186622 75119

3-Way (A)

85434

3-Way (B )

192842

Gas Equipment Catalog

Tube Length

Inlet Size (Tubing)

Horizontal Angle Type #2 Kit 1851-051 24” 1851-052 36” Horizontal Angle Type #4 Kit 1851-152 36” Vertical Bottom Inlet Type #6 Kit 1851-252 24” 1851-253 36”

Webb# —

Webb#

3/16” & 1/4”

192844 192845

3/16” & 1/4”

192847

3/16” & 1/4”

167046 85438

1890-100 (#11) Pilot Uni-Kit® The 1890-100 Pilot Uni-Kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. The kit comes with a Natural gas orifice instlled and includes a separate L.P. gas orifice. mfr# description 1890-100 36” Mini-Pilot, Type #6

webb# 167187

1898 Series Pilots 1898 Series Pilots are used with 4060 (MSA and MSC) Series Safety Valves. Suitable for natural or L.P. gas using the .14 universal orifice. MFR# 1890-022

tubing size 3/16”

tubing size Webb# .14 —

Gas Ignition Controls Replacement Sensors mfr# 10-277

description S1 Sensor has 1/4” quick-connect terminal

webb# 203364

victormfg.com


SECTION

8

Regulators Mercury Flame Sensors The Mercury Flame Sensor is a mechanical device that provides the existence of an acceptable pilot flame. When the bulb is heated by a pilot flame, the mercury is vaporized, causing pressure in the capillary and diaphragm, causing the snap-switch to open one set of contacts, and close a second set. These contacts control the pilot valve and the main valve. MFR# 3098-134 3098-156

element Length

panel type

48”

E

bulb style description Webb# #19 Replaces Bulb Styles #9 or #13. 118711 #20 Replaces Bulb Styles #17 or #18. 205641

3098-134

Gas Valves

1751 Add-On Pressure Regulator Kits The 1751 Series Add-on pressure regulator kits are available for use on the following factory model types; 7000, 7010, 7100, 7200 & 7222. SUITABLE FOR MFR# 1721-003

REGULATOR TYPE 3.5” W.C. Nat. Gas

NAT. GAS —

L.P. GAS —

Webb# 85406

1751-007

Regulator Cover Plate

192839

1751-003

4080 Pressure Regulators The 4080 Series Pressure Regulators are designed for main burner and pilot duty applications. The regulator is convertible with settings at 4” W.C. Natural gas and 10” W.C. L.P. gas on the 4080-032 and 4080-035.

4080-035

4080-035

pipe size 3/4” X 3/4”

regulator type 4” (Fixed) W.C. Natural Gas 10” (Fixed) W.C. L.P. Gas

suitable for

Webb#

Nat. Gas

73478

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Gas heating

MFR#

8

169


SECTION

8

Hot Surface Ignitors Gas Ignition Controls

41-400 Series Hot Surface Furnace Ignitors

41-401

41-402

41-403

41-404

41-405

Robertshaw’s 41-400 Series Norton Hot Surface Ignitors deliver dependable ignition heating systems of every description. From furnaces and boilers to rooftop heaters, infrared burners, unit heaters, water heaters and many other types of HVAC equipment. The 41-400 Series Hot Surface Ignitors are made of high-purity recrystallized silicon carbide (Crystar™) which combines physical and thermal strength with stable electrical properties. The 41-400 Series are designed to reach ignition temperature(s) within 17 seconds. They have 8-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity. The lead wires are also enclosed with a special high-temperature fiberglass insulation providing total electrical protection. MFR# 41-401 41-402 41-403 41-404 41-405 41-406 41-407 41-408 41-409 41-410 41-411 41-412 41-413

Factory lead wire Model length Webb# 271A 41/2” 73444 271W 19” 73445 51/2” 73446 271M 41/2” 110330 271D 51/2” 111617 271Y 101/2” 73447 271 111061 271N 153382 271 41/2” 80697 111618 271N 111619 271NM 51/2” 111620 201C 13/8” 189061

41-406

41-407

41-409

41-411

41-408

41-410

41-412

41-600 Series Hot Surface Furnace Mini-Ignitors

41-602

Robertshaw’s 41-600 Series Norton Hot Surface Mini-Ignitors deliver dependable ignition heating systems of every description. All Norton ignitors are engineered for easy handling, simple installation and trouble-free operation. MFR# 41-602 41-604 41-605

41-605

170

Factory Model 601TB 601XBM 601XBM + Harness & Brackets

Gas Equipment Catalog

housing length None 4”

comments Amana #20165702 Armstrong #44744-2

Webb# 250353 241291

2.5”

York Replacement Conversion Kit #473-20937-001

241292

victormfg.com


SECTION

8

Hot Surface Ignitors GlowFly Ignitor The Q3200U Universal Hot Surface Igniter Kit is designed to provide a robust field service replacement igniter in gas fired appliances with Norton/St Gobain 120 VAC silicon carbide hot surface igniters. The Q3200U uses a 120 volt silicon nitride igniter design with long life and high resistance to damage or burn out in the appliance. The kit includes the specially designed silicon nitride igniter and six different bracket configurations to adapt the igniter to the specific appliance application along with accessory parts to allow mounting and wiring the igniter. Clear instructions and application templates are provided to simplify selection of the proper bracket and ease installation of the replacement. MFR# HONQ3200U1004 HONQ3200U2002

DESCRIPTION GLOWFLY UNIV HOT SUR IGNITOR GLOWFLY UNIV HOT SUR IGNITOR (6PC)

Webb# 417300 417299

Hot Surface Ignitor

Igniters Direct are a durable universal direct upgrade for replacing most silicon carbide igniters. MFR# URK24V URK120VF URK120VR

comments 24V Hot Surface Igniter 120V Flat Universal Kit 120V Round Ignitor Kit

Webb# 309804 268458 401572

Ignitors Replaced by URK24V

8

The smart-lite™ igniter flame rod assembly is a direct replacement for all 24 volt hot surface igniter SmartValve™ systems and includes equipment made by AO Smith, Armstrong Furnace, Bradford White, Ducane and Skymark.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Gas heating

Used in SmartValve™ Replaces Igniter Flame systems including: rod assembly including: SV9500 1009524 SV9500M2603 1149856 SV9500M2674 42640001 SV9500M2682 CARQ3400A1024 SV9500M-2682 Q3400A SV9501M2528 Q3400A1016 SV9600 Q3400A1024 SV9600H Q3400A1040 SV9401 Q3450 SV9402 Q3480 SV9403 Q3620 SV9501 SV9502 SV9503 SV9601 SV9602

171


SECTION

8

Hot Surface Ignitors Ignitors Replaced by URK120VG & URK120VR Note: URK120VR may be used as a flame rod sensor. URK120VF may NOT.

Manufacturer American Road Equip Acro Air Armstrong Air Carrier Corporation Claire Brothers Coleman Comfort Maker Detroit Radiant DMO Industries Dornback Furnace Ducane Enerco Tech Evcon Goodman Heil Hupp Industries Intercity Majestic Metzger Mor-Flo Nordyne Norton Raypak Rheem Roberts Gordon Robertshaw Smith HB Snyder General Superior Fireplace Tempstar Trane Company Viessman Wayne Home Equip Weil McLain White LB Company White-Rodgers Williamson York International

172

Part Number 201W 1096048 | 1380680 38322B001 LH33ZS001A | LH33ZS002 C-238 | C-242 1474-051 | 1474-052 1096048 201D 20834 271W 20015201 10399 1474-051 | 1474-052 B10401009 1096048 9050 1009604 | 1096048 75-92-104 | 75-92-105 201N | 201W 3200618 105141000 | 632-0770 | 632-0880 | 902661 | 902694 | 903110 | FC007 201 | 201D | 201K | 201L | 201R | 201W | 271 | 271D | 271M | 271N | 271NM | 271P | 271W 600915 62-22441-01 | 62-22868-82 | 62-22868-93 90434300 | 90436600 41-402 | 41-403 | 41-404 | 41-405 | 41-407 | 41-408 | 41-409 | 41-410 | 41-411 | 41-412 | 41-414 50018 1380654 | 1380672 | 1380680 94851 1096048 | 1148245 340039P01 | B138196P01 | B144676P01 | B144676P02 | B340039P01 | IGN21 | IGN23 | IGN26 | IGN30 9302-094 62821-001 | 62821-002 511-330-139 | 511-330-190 | 511-330-193 120-07549 767A-301 | 767A-303 | 767A-306 | 767A-310 | 767A-311 | 767A-350 | 767A-353 | 767A-354 767A-357 | 767A-361 | 767A-364 | 767A-365 | 767A-366 | F767A-357 | F767A-361 | F767A-365 | F767A-366 9050 025-27766-000 | 025-27774-000 | 025-29043-000 | 025-29050-000 025-32625-000 | 025-32626-000 | 025-33421-000 | 373-05342-700 | 473-12509-001

Gas Equipment Catalog

victormfg.com


SECTION

8

Regulators WAGS Water and Gas Safety Valve The WAGS Water and Gas Safety Valve™. The WAGS valve shuts off the water supply (plus has supply for gas-fired water heaters) when it detects a water leak, preventing disastrous flooding and damage to structures and belongings. WAGS

mfr# WAGS7200

size & Connection Water and Gas Safety Shut-Off Valve for Hot Water Heaters

webb# 243562

FloodMaster, inc. Water Feed

Alarm/Shut-off System Kit • • • • • •

Easy installation. No wiring — just plug in. No maintenance. Audible alarm and interface with your home security system. NSF 61/UL/CE/CSA. Reusable.

mfr# FLOODMASTER

description Alarm/Shut-Off Kit

webb# 242185

Gas Guardian System The Gas Guardian™ Carbon Monoxide & Gas Leak Protection system has taken the original gas leak protection system a step further by adding a carbon monoxide alarm. When the alarm detects carbon monoxide at dangerous levels (as defined by the UL2034 and EN50291 standards) it will cause the gas valve to close, shutting down all gas-appliances and preventing further accumulation of carbon monoxide. This is all done automatically to protect your property, and give you complete peace of mind.

8

Mfr# Description Webb# QMIQGC201RGRS CO/GAS DETECTOR 411881 QMIQGKM511GRS CO/GAS GUARDIAN 411882

Gas heating

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

173


SECTION

9

Pump Accessories Positive Displacement Meters MA™ Series Meters MA-4™/MA-5™

MA-4 Meters in Class 10 construction are designed specfically for LPG motor fuel applications (UL Listed): • Capacity: 30 GPM (115 L/min.) • Choice of 11/2” standard and 2” optional companion flanges. MA-5 Meters in Class 10 construction are designed for LPG truck and high speed LPG motor fuel applications (UL Listed) • Capacity: 60 GPM (225 L/min.) • Choice of 11/2” standard and 2” optional companion flanges. MA-7™

MA-4-CX-10

MA-7 Meters in Class 10 construction are designed for LPG truck and bulk loading applications (UL Listed). • Capacity: 100 GPM (380 L/min.). • Class 12 construction for NH3 (Anhydrous Ammonia) service available upon request. • Choice of 2” NPT standard, 11/2” optional companion flanges. MA-15™

MA-15 Meters in Class 10 construction are designed for LPG bulk delivery truck and bulk loading applications (UL Listed). • Capacity: 200 GPM (760 L/min.) • Standard 3” inlet, 2” outlet with choice of NPT, BSPT or steel welding flange (3” outlet optional). MFR#

Description

MA-4+

MA-7-GY-10

MA-5+ MA-7+

350 PSI 21 BAR 2068 kPa

MA-15+

maximum nominal Flow rate

Standard Flange size

30 GPM (113 L/min.)

11/2” NPT

60 GPM (227 L/min.)

11/2” NPT

100 GPM (380 L/min.)

2” NPT

200 GPM (757 L/min.)

3” NPT

primary material

Webb# —

Aluminum

— — 251204

Model Description Chart – Example shown is meter model MA-15-GY-10

174

Gas Equipment Catalog

victormfg.com


SECTION

9

Pump Accessories Power Rewind Reels with Bottom-Mounted Guidemaster To handle single 1” or 11/2” I.D. hose

Series PBGMB The Hannay Series PBGMB hose reel is designed specifically for open-deck or compartment mounting, especially when recovery is of an angle other than straight off the reel. Rewind: Choose chain and sprocket drive powered by an electric, hydraulic, or compressed air motor. Gear-driven mechanism with pinion shaft brake can be specified as auxiliary crank rewind on power rewind reels, at extra cost. Brakes & Locks: These reels are supplied with a strap brake. Other brake and locking devices may be specified. Inlet: Standard inlet is 90° ball bearing swivel joint with 11/2” female NPT threads. Outlet: Standard outlet is flanged riser with 11/2” female NPT threads. Standard inlet, outlet riser, and hub assembly are steel. Other sizes and/or threads can be furnished and must be specified. Operating Pressures and Temperatures: These reels operate at pressures to 350 psi (24 bar) and handle product temperatures from -40° F to +350° F (-40° C to + 177° C). Reels to operate at other pressures and temperatures can be furnished at extra cost.

Series PBGMB

Hose capacity of reel feet (m) I.D. (in) I.D. (mm)

1” 25.4

11/2” 38.1

o.D. (in) o.D. (mm)

1.5” 38.1

2.16” 54.8

— —

125 45.7

50 15.2

— —

150 45.7

— —

200 61.0

MFR# For Power Rewind See Note 2

Reel Dimensions Inches (mm)

A

B

C

D

E

F Elec.

F. Air

F. Hyd

PBGMB 24-23-24

21 533.4

15.5 393.7

10.5 266.7

20.5 520.7

22.75 577.9

29.25 743.0

28.25 717.6

28.25 717.6

75 22.9

PBGMB 30-23-24

27.5 698.5

22 558.8

10.5 266.7

20.5 520.7

22.75 577.9

35.75 908.1

34.75 882.7

34.75 882.7

110 33.5

PBGMB 28-25-26

27.5 698.5

22 558.8

10.5 266.7

25.5 647.7

24.75 628.7

33.75 857.3

32.75 831.9

32.75 831.9

Webb#

Specifications subject to change.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

175

pumps/compressors

Dimensions and Capacities

9


SECTION

9

Pump Accessories Power Rewind Reels with Bottom-Mounted Guidemaster (continued)

Hose capacity of reel feet (m) I.D. (in) I.D. (mm)

1” 25.4

11/2” 38.1

o.D. (in) o.D. (mm)

1.5” 38.1

2.16” 54.8

MFR#

Approx Weight lb. kg.

Reel Dimensions Inches (mm)

For Power Rewind See Note 2

G

H

J

k

l

net

ship

Webb#

23.5 596.9

12.12 307.8

51 1295.4

39.75 1009.7

33 838.2

160 73

185 84

— —

125 45.7

50 15.2

PBGMB 24-23-24

— —

150 45.7

75 22.9

PBGMB 30-23-24

23.5 596.9

12.12 307.8

51 1295.4

43 1092.2

35.25 920.8

170 77

200 91

— —

200 61.0

110 33.5

PBGMB 28-25-26

27.88 708.2

15.5 393.7

52 1320.8

42 1066.8

35.25 895.4

173 78

203 92

Specifications subject to change.

Notes:

1. Upon request, reels can be supplied with drum lengths other than shown and with disc sizes in other diameters. 2. When ordering power rewind models, prefix model number with: A = Air Rewind – Supplied with control valve and hose. E = Explosion Proof Electric Rewind (1/2 HP) – Supplied with explosion proof switch, solenoid and junction box. HD = Hydraulic Rewind – Not supplied with control valve. 3. Dimension J is maximum, with fully extended Guidemaster in operating position. Dimension K is maximum, with fully extended Guidemaster in traveling position opposite rewind motor, as shown in dimensional drawing. Dimension L is maximum, with fully extended Guidemaster in travelling position on same side as rewind motor. (The telescoping feature of the Guidemaster permits each of these dimensions to be reduced up to 4”.) Maximum distance from frame of reel to outside edge of Guidemaster locked in traveling position is 11”.

Victor/F.w. Webb stocks siemens generators.

176

Gas Equipment Catalog

victormfg.com


SECTION

9

Pump Accessories

Flex Connectors

Flex Hose

mfr# size Webb# 1/2” X 12” 187507 FLES50-12 3/4” X 12” 187508 FLES75-12 FLES100-12 1” X 12” 187500 187501 FLES125-12 11/4” X 12” 187502 FLES125-18 11/4” X 18” 187503 FLES150-12 11/2” X 12” FLES200-14 2” X 14” 187505 FLES300-24 3” X 24” 187506

Other sizes can be custom made.

Style B 112, 600#, Threaded, Ductile Iron SC000B112AD Size

Weight

Webb#

SCSB112AD-34

MFR#

3/4”

21/2 lbs.

184112

SCSB112AD-1

1”

41/2 lbs.

261609

SCSB112AD-114

11/4”

7 lbs.

184114

SCSB112AD-112

11/2”

8 lbs.

184115

2”

15 lbs.

193217

SCSB112AD-2

Style C 103, 600#, Threaded with Bolted Cover, Ductile Iron SC000C103AD Size

Weight

Webb#

MFR#

2”

20 lbs.

SCB112AD-3

3”

41 lbs.

202666

4”

100 lbs.

pumps/compressors

Applications: General purpose Stainless Steel double braided metal flexible gas hose assemblies code rated @ 350 psi available with NPT, ASME flanges, and pipe weld ends. For use typically as a vibration dampener/flexible connector 1/2” – 4” sizes on pump, compressor, and generators. Also available UL536 listed Metal Hose Assemblies suited for Natural Flammable and Combustible Liquid and Gas Service @ 175 psi. All flexible connectors pictured have schedule 80 NPT threaded end with a corrugated stainless hose covered with a double braided stainless steel assembly cover.

Self-Cleaning Strainers

Style A 105, 300#, Flanged, Ductile Iron SC000C103AD MFR#

Size Weight Webb#

2”

39 lbs.

SCSSC0300A105AD

3”

65 lbs.

S497139

SCSSC0400A105AD

4”

130 lbs.

S497138

9

LP Gas Flowmeter Internationally recognized for our superior flowmeter replacement parts, Liqua-Tech now offers the Model LPM-102 LP Gasliquid flowmeter. Designed for retail sales dispensing units, the LPM-102 offers the widest flow range, (3-18 gpm) available in a meter of this type. In addition, the LPM-102 contains all required accessories including vapor eliminator, strainer and differential valve. mfr# LIQLPM102 —

DescRIPTION SIZE Webb# 3/4” 182604 1 Gal. Register — 2” —

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

177


SECTION

9

Pump Accessories Swivel Connectors

Full-Circle offers a complete line of swivel connectors designed for use with thin to viscous liquids and liquefied gases. Straight-through hose end swivels allow the filler valve to rotate 360°. This enables the driver to make tank connections without fighting the hose. It also prevents hose twisting upon reel-up. For bulk-head use, the 90° swivel allows for the use of a shorter transfer hose and enables the operator to safely sweep the hose to one side for proper, out of the way storage. The design is ideally suited for hose reel use as the sealed high load ball bearing can tolerate misalignment problems that could cause product leakage in other swivel types. The tri-directional movement of the three-piece seal package continually compensates SMAC-112LN; 11/2” FNPT 90° Swivel for eccentric movement. Additional Notes The Zero maintenance design is of critical importance, especially for leading/unloading Temperature range: arms that must be constructed high in the air for railroad tankcar transfer operation. -40°F to + 350°F Safety First All swivels produced by Full-Circle for LP-gas, ammonia, and flammable liquids Hydrostatic test pressure: are listed by the Underwriters Laboratories and are designed and tested in accordance with 2000 psi for ammonia swivels, the U.L.-567 standard, your assurance that the product has been tested to a standard of 1750 psi for other liquid/ safety. liquefied gases No Maintenance Design All Full-Circle swivels unitize a sealed high load ball bearing. Maximum working pressure: No greasing or lubrication is ever required. 400 psi for ammonia swivels, 350 No Rotating Rubber Seals All full-circle swivels incorporate the superseal™ mechanical psi for other liquid/liquefied gases seal. This patented design allows the seal ring to “float” between two metallic seals. While Maximum rotatinal speed: in operation, the seal ring rotates at one-half the swivel rotational speed. The tri-directional 1000 RPM movement of the seal components allows for continuous adjustment due to vibration, Maximum load on ball bearing at misalignment, and temperature extremes. Upon depressurization, the seal spring maintains 33 RPM: a constant force on the seal package, preventing product leakage in zero to low pressure 5000 lbs for 11/2” and 2” swivels, environments. 2000 lbs for other SMAC prefix Misalignment Minimized All Full-Circle swivels utilize a radial contact ball bearing swivels, and 1000 lbs for JO prefix swivels with extremely high load ratings. The bearing is sealed for life and requires no periodic lubrication. The ball bearing completely supports the rotating portion of the swivel to U.L. Standard: ensure smooth and easy movement. 567 Field Replacement Components All full-circle swivels are designed so that replacement parts can be installed simply and easily in the field with no special tools required. 90° Type — Same thread size for inlet and outlet MFR#

90° Type

Size

SMAC-3490LN

3/4” X 3/4”

SMAC-190LN

1” X 1”

SMAC-114LN

11/4” X 11/4”

SMAC-112LN

11/2” X 11/2”

SMAC-200LN

2” X 2”

Threads

A

B

Weight

Webb#

3”

45/8”

63/4 lbs.

283972

31/4”

43/4”

131/8 lbs.

309126

Female NPT

Straight Through Type — Same thread size for inlet and outlet MFR#

Straight Through Type

Size

SMAC-34STLN

3/4” X 3/4”

SMAC-1STLN

1” X 1”

SMAC-114STLN

11/4” X 11/4”

SMAC-112STLN

11/2” X 11/2”

SMAC-200STLN

2” X 2”

Threads

A

B

Weight

Webb#

51/4”

31/16”

41/2 lbs.

511/16”

47/8”

113/4 lbs.

Female NPT

Straight Through Hose-End Filler Valve Type — Allows filler valve to rotate 360° Straight-Through Hose End Filler Valve Type

178

MFR#

Size

Threads

A

B

Weight

Webb#

JO-1LN

1” X 1”

Female X Male

33/8”

21/2”

11/2 lbs.

246584

Gas Equipment Catalog

victormfg.com


SECTION

9

Pump Accessories Krug Compressor mfr# description KRUH50LP Transfer Compressor, LP Engine KRUH50G Transfer Compressor, Gas Engine

webb# 182405 182404

Basic Hose Kit

pumps/compressors

qty mfr# description webb# Liquid Transfer Hose 30’ HOS3/4 3/4” LP Hose 185604 2 HOSHY12-12MP 3/4” Hydraulic Coupling, 2 pieces in kit 185576 Compressor Inlet Hose (Bobtail to Compressor) 12’ HOS1/2 1/2” LP Hose 185581 2 HOS7661-08MP08TY 1/2” Hydraulic Coupling 193208 Compressor Outlet Hose (Compressor to Tank to be Evacuated) 25’ HOS1/2 1/2” LP Hose 185581 2 HOS7661-08MP08TY 1/2” Hydraulic Coupling 193208 Fittings 1 RGO3175 3/4” Hose Coupling 162687 1 F/S34CO3SE 3/4” Hose Coupling, 3M 8735 1 RGO7550P 3/4” Transfer Angle Valve 162760 1 RGO3165CP 1/4” Bleeder Valve* 186852 1 RGO7590U-10 3/4” Check Lock Adapter* 162762 1 RGO3175B 1/2” Hose Coupling 186853 1 RGO3171A 1/2” Vapor Coupling 162686 2 JOM100-703 1/2” Ball Valve 151448 *Install in 7550P for new style Checklok

9

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

179


Pump Station Kits

SECTION

9

Pump Station Without Meter

180

Gas Equipment Catalog

victormfg.com


SECTION

9

Pump Station Kits

Pump Station Without Meter

(continued)

Pump Station Schematic Drawing Key No Meter Drawing

Qty Alpha Code Description Webb#

1

1

1

G/T1000AG

1000 Gal. Above Ground LP Tank

185224

1

G/T500AG-B

500 Gal. Above Ground LP Tank

215818

2 (A,B,C) 1

VCTTANKST

Victor Tank Stands, Pump Mount, and Meter Mount

184438

3

42’

D/P114BPE

11/4” X 21’ sch40 black pipe price per foot. Use 2 full lengths each leg for 1000 gal., cut 2 to 16’ for 500 gal.

4

Checklok Emergency Liquid Evacuation Valve (Possible Rego 7590U)

45533 —

5

POL Service/Vapor Evacuation Valve (Possible Rego 7556R12.0)

6

Double Check Filler Valve (Possible Rego 7579)

7

1

RGOA8017DP

Bottom Tank Valve Liquid Service 11/4” X 1”

8,9

1

CRKC12SMB

Corken Pump C12SMB 11/2” Pnlet 1” Putlet 1 HP Motor With Switch Mounted On Motor And B166 Bypass 181039

10

1

NIPCS114X1XH

11/4” X 1” Concentric Swedge Nipple XH

11

2

F/S114903SE

11/4” 90 Elbow 3000# Forged Steel Threaded

12

1

NIP114X10XH

11/4” X 10” XH Black Nipple

13

1

SCSB112AD-114 11/4” Ductile Iron Strainer Threaded

14

1

F/S34PL

3/4” Plug 3000# Forged Steel Square Head Threaded

15

1

NIP114X8XH

11/4” X 8” XH Black Nipple

1

FLES125-12

11/4” X 12” Stainless Steel Double Braided Flex Connector With SCH80 Threaded Ends

1

F/S114UN3SE

11/4” Union 3000# Forged Steel Threaded

18

1

F/S112X114BU

11/2” X 11/4” Bushing Forged Steel

19

1

NIPCS1X34XH

1” X 3/4” Concentric Swedge Nipple XH

20

1

F/S34T3SE

3/4” Tee 3000# Forged Steel Threaded

21

4

NIP34X6XH

3/4” X 6” XH Black Nipple

187220 8693 187212 184114 8831 14636 187501 9101 8872 187219 8715 14602 162428

22

1

RGO3127U

Rego 1/4” Hydrostatic Relief Valve 450#

25

1

F/S14S903SE

1/4” Street 90 Elbow 3000# Forged Steel Threaded

26

1

CRK1449

Corken Gauge Adapter/Pressure Snubber 1/4” M/F

181098

27

1

RGO1224WA

Rego 1/4” Needle Valve

186802

8723

28

1

F/S14C03SE

Coupling 3M FS TH 1/4”

29

1

GAUP300

Ashcroft 21/2” Dial 1/4” Bottom Connection 0-300 psi

36489

31

21

D/P34XHBPE

3/4” X 21’ SCH 80 Black Pipe Price Per Foot

45478

30

6

F/S34903SE

3/4” 90 Elbow 3000# Forged Steel Threaded

8691

32

1

RGO7550P

Rego 3/4” Angle Valve M/F

162760

33

1

RGO7590U-10

Rego Check-lok Adapter, Possible Alternate RGO7572-14C For Older Style Check-lok

162762

34

1

F/S34CO3SE

3/4” Coupling 3000# Forged Steel Threaded

35

2

HGR1GUBOLT

1” Galvanized U-Bolt With Nuts

8735 69033

36A

3

HOS3/4

3’ - 3/4” LP Dayco Hose

185604

36B

2

HOSHY12-12MP 3/4” Hydraulic Hose Ends For Dayco Hose

185576 162683

37

1

RGOA2141A6

Rego 3/4” Breakaway/Pullaway Coupling

38

1

F/S34X12BU

3/4” X 1/2” Bushing 3000# Forged Steel

39A

18

HOS1/2

18’ - 1/2” LP Dayco Hose

39B

2

HOS7661-08MP08TY 1/2” Hydraulic Hose Ends For Dayco Hose

40

1

RGO7901TB

Rego 1/2” X 1/4” Snap Acting Hose Valve

162488

41

1

RGO7193D-10

1/4” X MPOL Rego Hose Adapter

186884

not shown

1

RGO7193T-10

FPOL X 15/16 F Acme Adapter Rego FPOL-QCC1 Adapter

162472

not shown

1

FBS1124

Fairbanks 1124 1000# Scale

181957

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

8857 185581 193208

181

pumps/compressors

16 17

162493

9


Pump Station Kits

SECTION

9

Pump Station With Meter

182

Gas Equipment Catalog

victormfg.com


SECTION

9

Pump Station Kits

Pump Station With Meter

(continued)

Pump Station Schematic Drawing Key With Meter Drawing

Qty Alpha Code Description Webb#

1

1

G/T1000AG

Tank LP Above Ground 1000 Gal.

185224

1

1

G/T500AG-B

Tank LP Above Ground Bot./Drn. 500

215818

Nut Short Ref. 3/8” * NS45 E6NUT

2

2

SAE38RNUT

3

1

SAE38X14MUN Union 3/8 X 1/4 FLR X M * U1-6B

4

1

SAE38X14M90

ELL 90 3/8 X 1/4 FLR X M * E1-6B

5

1

PIG1005

POL X 3/8 Male Flare

34571 19780 19834 186522

6

2

SAE58X34MUN Union 5/8 X 3/4 FLR X M * U1-10E

19791

7

2

SAE58RNUT

Nut Short Ref 5/8 * NS410 E10NU

34814

8

1

RGO7550P

Valve Angle Trans. * 3/4

162760

9

1

RGO7590U-10

Adapter Check Lock * 3/4

162762

10

2

RGO3127U

Valve Relief Hydro 450 1/4”

162428

11

1

RGOA8017DP

Valve Multi Purpose 11/4 MN

162493

12

1

NIPCS114X1XH Nipple Conc. Swedge 11/4 X 1 X H

13

1

F/S1903SE

Elbow 90 3M FS TH 1”

1

NIP1X 3XH

Nipple Black X H 1 X 3 STL

1

F/S114903SE

Elbow 90 3M FS TH 11/4”

16

1

NIP114XHPAK

Nipple BLK X H PAK 1 EA 11/4 X CLO

17

1

SCSB112AD-114 STRNR 11/4 DI 600 THD 20” MESH

18

1

F/S1PL

Plug 3M FS SQ HD 1”

19

1

FLES125-12

Hose 11/4 X 12 SS SGL BRD S80MN Union 3M FS TH AAR 11/4”

20

1

F/S114UN3SE

21

1

NIPCS112X114XH Nipple Conc. Swedge 11/2 X 11/4 X H

8692 14612 8693 111655 184114 8832 187501 9101 187221

22

1

CRKC12SMB

Kit Pump 1 HP MTR MNT SW 3/4 BY

181039

23

1

NIPCS1X34XH

Nipple Conc. Swedge 1 X 3/4 X H

187219

24

1

F/S34T3SE

Tee 3M FS TH 3/4”

25

1

NIP34XHPAK

Nipple BLK X H PAK 1 EA 3/4 X CLO

26

1

F/S34UN3SE

Union 3M FS TH AAR 3/4”

27

1

NIP34X24XH

Nipple Black 34 X 24 X H WLD

8715 111669 9099 318897

28

3

F/S34903SE

Elbow 90 3M FS TH 3/4”

8691

29

1

F/S34T3SE

Tee 3M FS TH 3/4”

8715 8857

30

1

F/S34X12BU

Bushing 3M FS HEX 3/4 X 1/2

31

1

RGO3129U

Valve Relief Hydro 450 1/2”

32

1

LIQLPM102

Meter Flow With 1 Gallon Register

182604

33

1

RGO3272G

Valve Excess Flow 3/4”

162584

34

3

HOS3/4

Hose LP 3/4 7132-75354

35

2

HOSHY12-12MP Coupling Hydraulic 3/4

36

1

RGOA214A6

Valve Pull Away 3/4”

37

1

F/S34X12BU

Bushing 3M FS Hex 3/4 X 1/2

38

18

HOS1/2

Hose LP 1/2 7132-50354

39

2

HOS7661-08MP08TY Coupling Hydraulic 1/2

40

1

RGO7901TB

Valve Quick Act 1/4 FN X 1/2 FN

162488

41

1

RGO7193D-10

Connector Fill With Soft Nose

186884

42

1

RGO7193T-10

Adapter Fill FPOL X 15/16 AC

43

1

RGO07193L-10A Connector Fill

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

162432

185604 185576 162683 8857 185581 193208

162472 162471

183

pumps/compressors

14 15

187220

9


SECTION

9

Pump Station Kits Pump Station With Meter

(continued)

Pump Station Schematic Drawing Key With Meter Drawing

Qty Alpha Code Description Webb#

44

1

RGO5760A

Adapter FP X 1/4 FN

162457

45

1

SHR901H

FPOL X 13/4 Acme S

184119

46

1

CRK1449

Adapter Pressure Gauge

181098

47

1

F/S14S903SE

Elbow 90 3M FS TH ST 1/4”

48

1

RGO1224WA

Valve Needle Brass 1/4

49

1

F/S14CO3SE

Coupling 3M FS TH 1/4”

8723 186802 8732 110920

50

1

ASH00516

Gauge 63 3005PHL 02L 300

51

42

D/P2BPE

Pipe S40 BLK PE 2 X FT

52

8

HGR12GWASHER Washer Flat PLT 1/2 130 PG

53

4

HGR12GNUT

54

4

HGR12X2GBOLT Bolt HEX HD GAL 1/2 X 2 41 PG

55

1

VCTTANKST

Stands Tank With Pump

184438

56

1

FBS1124

Scale Portable Beam

181957

57

1

MIL48-89-1565

Bit Twist Drill 1/4

74665

58

1

MIL48-89-1645

Bit Twist Drill 1/2

247642

59

15 Feet 1/4 K Soft Copper

362953

60

10 Feet 1/2 K Soft Copper

360279

Nut HEX HD PLT 1/2” 110 HPG

45504 69051 69046 34458

Victor/F.w. Webb stocks york furnaces.

184

Gas Equipment Catalog

victormfg.com


SECTION

9

Pumps/Compressors Coro-Flo® Turbine Pumps Stationary Applications

C-Model With Close Coupled Motor

Designed specifically for LPG The Corken Coro-Flo® pump was designed for LPG, NH3 and other light liquids. For lowcapacity, medium-head pumping, the Coro-Flo pump is the pump of choice. Extremely quiet and free of vibration and pulsation, the Coro-Flo pump provides trouble-free service and long life for volatile liquids such as LPG. The exclusive turbine construction provides smooth continuous flow through the pump case, resulting in higher efficiency and greater capacity and pressure for the same size motor. The one moving part, the impeller, floats on the shaft without contacting adjacent surfaces, thus extending pump life. Simple to Service The Coro-Flo® pump has been designed for simplicity of inspection and service. The cover can be removed and the impeller and seal serviced without disturbing the piping. The balanced mechanical seal is furnished with its own sleeve, providing extremely reliable service. The Coro-Flo pump is listed by Underwriters’ Laboratories, Inc. for use in LP-Gas and anhydrous ammonia service. mfr# description Dispensing Station Pumps CRKC10S 3/4 HP, 115/230V Remote

webb# 181031

CRKC10SB

3/4 HP, Remote Switch, Bypass

181032

CRKC10SM

3/4 HP, 115/230V Switch

181033

CRKC10SMB

3/4 HP, SW Mount & Bypass

181034

CRKC12

1 HP Motor

181035

CRKC12S

1 HP 115/208/230 Remote

181036

CRKC12SB

1 HP Motor, Remote Switch

181037

CRKC12SM

1 HP 115/208/230 Switch

181038

CRKC12SMB

1 HP Kit, SW Mount 3/4 Bypass

181039

CRKC13

2 HP Motor

212890

CRKC14

3 HP Motor, SW Mount

204939

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

pumps/compressors

SPECIFICATIONS MODEL 10 12 13 14 Inlet 11/4” NPT 11/2” NPT 11/2” NPT 11/2” NPT Outlet 1” NPT 1” NPT 1” NPT 1” NPT RPM-60 Hz 3450 3450 3450 3450 Max. Differential Press. 50 Hz PSI (Bar) 60 (4.1) 75 (5.2) 75 (5.2) 75 (5.2) 60 Hz PSI (Bar) 70 (4.8) 100 (6.9) 125 (8.6) 125 (8.6) Mounting Options Close Coupled Yes Yes Yes Yes Direct Driven (101) Yes Yes Yes Yes V-Belt (103) Yes Yes Yes Yes Direct Mounted Frame (DS/DL) Yes Yes Yes Yes Double Seal Option (Except C-Model) Yes Yes Yes Yes Flange Option 11/2” X 1” — 300# Yes Yes Yes Yes (Except C-Model) Impeller Material Opt. Bronze (Standard), Ductile Iron, Stainless Steel O-Ring Material Opt. Teflon(r), Viton(r), Buna-N (Standard), Neoprene(r), Teflon(r), Ethylene-Propylene Viton(r), Ethylene-Propylene Seal Seat Material Options Ceramic Ni-Cast Iron, Cast Iron (Standard), Ni-Resist, Stainless Steel, SS304, Tungsten Carbide Tungsten Carbide, Ceramic Temperature -25/225°F -25/225°F -25/225°F -25/225°F (min/max) -32/107°C -32/107°C -32/107°C -32/107°C Maximum Driver 5 HP 10 HP 10 HP 20 HP 3.7 KW 7.5 KW 7.5 KW 15 KW

9

185


SECTION

9

Pumps/Compressors Coro-Flo® Turbine Pumps Stationary Applications (continued) Wire Sizing Chart Motor

Motor Phase 1 —

c12

1

1

c13

2

1

c14

3

3

Model c9 c10

HP 3/4

(a) recommended Wire Size, AWG approximate full load amperes 9.0 5.0 16.0 8.0 20.0 10.0 8.0 4.0

volts 115 230 115 230 115 230 230 460

Length of Run in Feet 0-100 12 12 8 12 8 12 12 12

to 200 8 12 6 12 4 10 12 10

to 300 6 12 4 10 2 8 12 8

Pump must rotate in the direction shown on pump case. If not, switch any two of the three incoming 3 phase lines.

115V 115V

208-230V 208-230V

208-230V 208-230V

2277-X12277-X1 OR 2277-X2 SWITCHSWITCH2277-X12277-X1 OR 2277-X2 SWITCHSWITCH OR 2277-X2 OR 2277-X2 T3

T3

T1

T1T1

T2

T1 L1

T1

L1 LINE

T2 LINE

T4

T4 T2

T2

L2

L2

LINE

T1 T1

T2 LINE

T1

L1

LINE

4

4 7

7 1

LINE 1

LINE 4

4 7

7 1

LINE 1

LINE

5

5 8

8 2

LINE 2

LINE 5

5 8

8 2

LINE 2

LINE

6

6 9

9 3

LINE 3

LINE 6

6 9

9 3

LINE 3

LINE

L1

T2

T3 LINE T4

460V 460V

T3 LINE

T4

T2

T2

L2

LINE

L2

FOR MODELS C9, C10, FOR MODELS C9,C12 C10,AND C12C13 AND C13

FOR MODELS C14 ONLY FOR MODELS C14 ONLY

Victor/F.w. Webb stocks electrical test equipment. See our tools section in this catalog.

186

Gas Equipment Catalog

victormfg.com


SECTION

9

Pumps/Compressors Coro-Flo® Pumps Autogas Pumps Corken Autogas Pump achieves new levels of performance with higher flows at high differential pressures, non-pulsating and quiet transfer, longer pump life and a design that is easy to repair. The pump is also versatile enough to be used in like applications such as cylinder filling, vaporizer feeding, or bulk transfer. mfr# description

FF150CD6A

webb#

Dispensing Station/Aerosol/Refrigerant Pumps CRKF10CD Pump f/10

181043

CRKF12CD

Bare Coro-Flo

181044

CRKF14CD

Bare Coro-Flo

181045

CRKDL14

Direct Mount, Large Frame

181211

CRKDS12CDC

Direct Mount, Small Frame

181216

FF150CD6A

Autogas Pump

369968

F-Model The F-Model pump is the base plate mounted version. Coro-Flo® pumps are design to operate at shaft speeds between 2880—3600 rpm. The F-Model provides the flexibility of motor selection. F-Model 101 Direct Drive

Autogas Pumps — Operating Specifications Models

DS/DL-Model Direct Mounted

Specifications Inlet Outlet RPM—50 Hz RPM—60 Hz Maximum Working Pressure Maximum Differential Pressure 50 Hz 60 Hz Mounting Options Direct Driven (101) V-Belt (103) Direct Mounted Frame Impeller Material Options O-Ring Material Options Seal Seat Material Options Temperature (Min/Max)

1 Neoprene®, Viton® and PTFE® are registered trademarks of the DuPont Company.

Maximum Driver Type of Electric Motor

FF150

dlf150

11/2” ANSI 300# R.F. Flange 1” ANSI 300# R.F. Flange 2,880 3,450 28.5 bar (400 psi)

11/2” ANSI 300# R.F. Flange 1” ANSI 300# R.F. Flange 2,880 3,450 28.5 bar (400 psi)

200 psi (13.8 bar) 200 psi (13.8 bar) 250 psi (17.2 bar) 250 psi (17.2 bar) — — Yes No Yes No No Yes Bronze (Standard), Ductile Iron, Stainless Steel Buna-N (Standard), Neoprene®1, PTFE®1, Viton®1, Ethylene-Propylene Cast Iron (Standard), Ni-Resist, Stainless Steel, Tungsten Carbide, Ceramic (-25) 225ºF (-25) 225ºF (-32) 107ºC (-32) 107ºC 20 hp 20 hp 15kW 15kW Rigid-Base C-Face

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

187

pumps/compressors

DS/DL Model The DS/DL Model pumps are designed to eliminate the need for a baseplate, coupling guard, and coupling alignment which makes the DS/DL series pumps compact and easy to install. The special bracket supports both the pump and the motor so they can be directly coupled.

9


SECTION

9

Pumps/Compressors Coro-Flo速 Pumps

(continued)

Autogas Capacity Chart 17.5

250

17.5 Curves based on L/min Capacity Power Required

15.0

15.0

20.0

200 12.5 15.0 10.0

10.0

7.5

7.5

5.0

5.0

bar

150

hp

100

kw

Differential Pressure psi

12.5

10.0 7.5

5.0

50 2.5

2.5 3.0

0

0

0

50

100

150

200

250

0

0

L/min. 0

10

20

30

40

50

60

gpm Capacity

Victor/F.w. Webb stocks the laars mascot gas boiler. it provides both heat and domestic hot water!

188

Gas Equipment Catalog

victormfg.com


SECTION

9

Pumps/Compressors Coro-Vane® Pumps Corken Coro-Vane® pumps are positive displacement pumps. They produce a maximum differential pressure of 125 psig (8.6 bar g). Corken manufactures four sizes of Coro-Vane pumps, ranging from 1gpm to 350 gpm (0.2–79.5 m3/hr). Corken offers these pumps with v-belt or direct-drive mounting options.

Z-Series Z3500 Stationary and Truck Pump The new three-inch Z3500 LPG pump is designed for stationary and foot mounted truck applications. The Z3500 stationary pump has the same locked rotor design used in the Corken Z-Series truck pumps to ensure long pump life and excellent performance. With higher flow rates than other three-inch pumps, the Z3500 retrofits Corken’s and other competitive pumps with little or no change in piping.

1021ef103

Bulk Filling, Carousel Filling & Cylinder Filling mfr#

webb#

Stationary Plant Pumps CRK521EF* Stationary Coro-Vane

181022

CRK521EG103*

Coro-Vane Pump With Mount

181023

CRK1021EF*

Bare Coro-Vane Pump

181013

CRK1021EF103*

Coro-Vane Pump With Mount 284T

181042

Z3500

Coro-Vane Z-Pump

401115

Z3500-103

Pump With Mount

401116

pumps/compressors

521 Cutaway

Description

*Soon to be obsolete.

M3/hr 10

20

30

40

50

60

80

950 860

RPM

640

100 PSID (6.90 Bar)

521

1021

1521

420 950 860 640

9

40 PSID (2.76 Bar)

521

1021

1521

420 100

150

200

250

300

GPM

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

189


SECTION

9

Pumps/Compressors Coro-Vane® Truck Pumps

The Z-Series Coro-Vane® truck pumps are specifically designed to perform in such severe operating conditions as high differential pressure, pump overspeeding, poor suction conditions and heavy thrust loads associated with a power take-off (PTO) drive system. mfr#

Description

webb#

Coro-Vane Pump Trucks CRKZ3200 Pump Truck

181234

CRKZ4200

204940

4” Transport

Specifications

Z3200

specifications models Z3200 Z4200 Suction Flange 3” 4” 300# ANSI 300# ANSI Discharge Flange 2” 2” NPT EI Dual NPT Maximum RPM 800 Minimum -25°F Temperature (-32°C) Maximum 225°F Temperature (107°C) Maximum 400 PSIG Working Pressure (28.6 Bar) Maximum 125 PSID Differential Pressure (8.6 Bar) Discharge Flange Open Yes No Internal Relief Valve Yes Yes Steel Slip-On Flange Option Yes Yes

Z4200

Z3200 Performance Chart Pump Speed rpm 800 800 650 650 500 500

190

Differential pressure psi 50 100 50 100 50 100

bar — 6.9 3.4 6.9 3.4 6.9

approximate delivery on propane gpm 121 110 98 88 73 63

Gas Equipment Catalog

lpm 460 420 371 333 276 238

brake hp required bhp 6.6 10.6 5.2 8.2 3.8 5.8

KW 4.9 7.9 3.9 6.1 2.8 4.3

pump torque required ft. lbs. 43.4 69.3 42.0 66.3 39.9 60.9

kg/m 6.0 9.6 5.8 9.2 5.5 8.4

victormfg.com


SECTION

9

Pumps/Compressors Compressor The “107” bulk plant gas compressor unit is complete with pressure gauges, steel baseplate, mechanical liquid trap, four-way valve, strainer, interconnecting piping, adjustable driverslide-base, v-belt drive and beltguard ready to receive an electric motor. This standard unit is typically used for liquid transfer and vapor recovery in applications including rail car and truck loading and unloading. Many options such as ASME liquid traps with Class1, Group D switches and total engineered packages can be provided.

Model 107

mfr# description Gas Transfer Compressors CRK91-107A (see table below) CRK291-107 (see table below) CRK491-107 (see table below) CRK691-107 (see table below)

webb# 181024 — — —

pumps/compressors

SPECIFICATIONS MODEL 91 291 491 691 891 Bore of Cylinder Inches (MM) 3.0 (76.2) 3.0 (76.2) 4.0 (101.6) 4.5 (114.3) 4.5 (113) Stroke Inches (MM) 2.5 (63.5) 2.5 (63.5) 3.0 (76.2) 4.0 (101.6) 4.0 (101.6) Piston Displacement CFM (m3/HR) Minimum @ 400 RPM 4.0 (6.8) 8.0 (13.6) 17.2 (29.2) 29.2 (49.6) 56.6 (96.2) 76.8 (130.5) Maximum @ 825 RPM 8.3 (14.1) 16.5 (28.0) 35.5 (60.3) 60.2 (102.3) 113.2 (192.0) Maximum @ 1200 RPM — — — — — Max. Working Pressure 350 (24.1) 350 (24.1) 350 (24.1) 350 (24.1) 465 (32.1) Max. Brake Horesepower (KW) 7.5 (5.6) 15 (11) 15 (11) 35 (26.1) 45 (34) Maximum Rod Load LP (KG) 3600 (1632.9) 3600 (1632.9) 4000 (1814.4) 5500 (3175.2) 7000 (3175.2) Max. Outlet Temp. °F (°C) — — — 350 (177) — Bare Unit Weight LB (KG) 115 (52.2) 160 (72.6) 260 (117.9) 625 (283.5) 855 (387.8) Maximum Flow-Propane 50 (11.4) 101 (22.9) 215 (48.8) 36 (82.0) 694 (157.6) GPM (m3/HR) ANSI/DIN Flange Option F91 F291 F491 F691 —

9 Victor/F.w. Webb stocks rinnai continuum water heaters. we can also help you size your job!

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

191


SECTION

9

Pumps/Compressors Compressor Selection Appendix C—Compressor Selection Propane Propane Compressor Selection Table Compressor Selection Table

Service Small bulk plants

Unloading single tank car or transport

Unloading two or more tank cars at one time or large transport with excess flow valves of adequate capacity

Unloading large tank cars, multiple vessels, barges or terminals

Capacity Displacement Compressor gpm1 cfm Model RPM 23 4 91 400 29 5 91 505 34 6 91 590 40 7 91 695 39 7 290, 291 345 45 8 91 795 44 8 290, 291 390 50 9 290, 291 435 56 10 290, 291 490 61 11 290, 291 535 66 12 290, 291 580 71 13 290, 291 625 79 14 290, 291 695 84 15 290, 291 735 84 15 490, 491 345 89 16 290, 291 780 89 16 490, 491 370 95 17 490, 491 390 101 18 490, 491 415 106 19 490, 491 435 108 20 490, 491 445 114 21 490, 491 470 119 22 490, 491 490 125 23 490, 491 515 130 24 490, 491 535 136 25 490, 491 560 141 26 490, 491 580 147 27 490, 491 605 152 28 490, 491 625 158 29 490, 491 650 163 30 490, 491 670 163 30 690, 691 400 168 31 490, 491 695 171 31 690, 691 420 179 32 490, 491 740 178 32 690, 691 440 186 34 690, 691 455 193 35 690, 691 475 200 36 690, 691 495 208 38 690, 691 510 215 39 690, 691 530 223 41 690, 691 550 230 42 690, 691 565 237 43 690, 691 585 245 45 690, 691 605 252 46 690, 691 620 260 47 690, 691 640 275 48 690, 691 675 297 54 690, 691 730 319 58 690, 691 785 334 60 690, 691 820 452 82 D891 580 623 113 D891 800

Driver Horsepower Liquid Liquid Transfer Transfer & Without Residual Residual Driver Sheave Size Vapor Vapor Pitch Diameter (inches)2 Recovery Recovery 1,750 RPM 1,450 RPM 100°F 80°F 100°F 80°F A 3.0 A 3.6 5 3 3 3 A 3.8 B 4.6 5 5 5 5 B 4.6 B 5.6 5 5 5 5 B 5.4 B 6.6 5 5 5 5 A 3.0 A 3.6 3 3 3 3 B 6.2 B 7.4 7-1/2 7-1/2 7-1/2 7-1/2 A 3.4 B 4.0 5 3 3 3 A 3.8 B 4.6 5 5 3 3 B 4.4 B 5.2 5 5 5 5 B 4.8 B 5.8 5 5 5 5 B 5.2 B 6.2 7-1/2 5 5 5 B 5.6 B 6.6 7-1/2 5 7-1/2 5 B 6.2 B 7.4 7-1/2 7-1/2 7-1/2 7-1/2 B 6.6 B 8.0 10 7-1/2 10 7-1/2 A 3.0 A 3.6 7-1/2 7-1/2 5 5 B 7.0 B 8.6 10 10 10 10 A 3.2 A 3.8 7-1/2 7-1/2 7-1/2 5 A 3.4 B 4.0 7-1/2 7-1/2 7-1/2 7-1/2 A 3.6 B 4.4 10 7-1/2 7-1/2 7-1/2 A 3.8 B 4.6 10 7-1/2 7-1/2 7-1/2 B 4.0 B 4.8 10 7-1/2 7-1/2 7-1/2 B 4.2 B 5.0 10 7-1/2 7-1/2 7-1/2 B 4.4 B 5.2 10 10 7-1/2 7-1/2 B 4.6 B 5.6 10 10 10 7-1/2 B 4.8 B 5.8 15 10 10 10 B 5.0 B 6.0 15 10 10 10 B 5.2 B 6.2 15 10 10 10 B 5.4 B 6.4 15 10 15 10 B 5.6 B 6.6 15 15 15 15 B 5.8 B 7.0 15 15 15 15 B 6.0 15 15 15 15 B 4.4 B 5.2 15 15 10 10 B 6.2 B 7.4 15 15 15 15 B 4.6 B 5.6 15 15 10 10 B 6.6 B 8.0 15 15 15 15 B 4.8 B 5.8 15 15 10 10 B 5.0 B 6.0 15 15 15 10 B 5.2 B 6.2 15 15 15 10 B 5.4 B 6.4 15 15 15 15 B 5.6 B 6.8 20 15 15 15 B 5.8 B 7.0 20 15 15 15 B 6.0 A 7.0 20 15 15 15 B 6.2 B 7.4 20 15 15 15 B 6.4 A 7.4 20 15 15 15 B 6.6 B 8.0 20 15 15 15 B 6.8 20 20 15 15 B 7.0 A 8.2 20 20 20 15 B 7.4 B 8.6 25 20 20 20 B 8.0 B 9.4 25 20 20 20 B 8.6 25 20 25 20 TB 9.0 A 10.6 30 25 25 20 5V 7.1 5V 8.5 30 30 30 30 5V 9.75 5V 11.8 40 40 30

Piping Size3 Vapor Liquid 3/4 1-1/4 3/4 1-1/4 1 1-1/4 1 1-1/2 1 1-1/2 1 1-1/2 1 1-1/2 1 1-1/2 1 2 1 2 1 2 1-1/4 2 1-1/4 2 1-1/4 2-1/2 1-1/4 2-1/2 1-1/4 2-1/2 1-1/4 2-1/2 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 4 1-1/2 4 1-1/2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 3 6 3 6

1

The capacities shown are based on 70°F, but will vary depending upon piping, fittings used, product being transferred and temperature. The factory can supply a detailed computer analysis if required. 2 Driver sheaves: 91 (2 belts); 290, 291, 490, 491 (3 belts); 690, 691 (4 belts). 3 The piping sizes shown are considered minimum. If the length exceeds 100 ft., use the next larger size. NOTE: Please consult factory for compressors with higher flows.

192

Gas Equipment Catalog

36

victormfg.com


SECTION

9

Bypass Valves Bypass Valves ZV200 Bypass Valve The two-inch ZV200 is a low pressure build-up bypass valve designed for applications requiring protection for positive displacement pumps. Specifically designed for protecting pumps with capacities up to 250 gpm (946 L/min). The continuous internal bleed will assist in the operation of systems with “air” or “electric” operated internal valves. Typical applications include bobtail, transport and stationary loading and unloading of LPG, NH3 and other light liquids. Applications Used for both truck and stationary applications for loading and unloading.

ZV200

Features and Benefits • Dimensionally interchangeable with commonly used two-inch bypass valves; no need to change piping configuration. • Ductile iron construction offers maximum strength for higher pressures. • Flow rates up to 250 gpm (946 L/min) at 120 psi (8.3 bar) differential. • Continuous bleed helps equalize pressure to assist remote operated internal valves. • Multiple spring options enable you to select the pressure required for your truck or stationary application.

Bypass Valves—Specifications for B166, T166, B177 and ZV200 pumps/compressors

Models Specifications

B166B

T166

B177

ZV200

Inlet

3/4”, 1”

11/4”, 11/2”

2”, 21/2”

2”

Outlet

3/4”, 1”

11/4”, 11/2”

2”, 21/2”

2”

No

No

2”, 21/2”

No

22 – 225 psi

22 – 225 psi

10 – 125 psi

91 – 125 psi

Slip-On Flange Option Differential Pressure Range

Buna-N (Standard), Neoprene 1, PTFE 1, Viton 1, Ethylene-Propylene*

O-Ring Material Options

®

®

®

* Ethylene-Proplyene not available for B177, 1 PTFE , Vitron and Neoprene® are registered trademarks of the DuPont Company. ®

MFR#

®

Description

WEBB#

B166B75B

3/4” Coro-Flo /Autogas

181026

B166B1B

1” Coro-Flo®/Autogas

181025

B177125B

11/4” Coro-Vane®

181027

B177150

11/2” Coro-Vane®

181028

B1772B

2” Coro-Vane®

181029

11/4” Truck Pump

181049

T166–1.25

®

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

9

193


SECTION

9

Bypass Valves Bypass Valves

(continued)

B166 (3/4” and 1”) Automatic Dual Purpose, Bypass Valves The B166B is a combination bypass and priming valve specifically designed for small cylinder filling type pumps, especially of the regenerative turbine type, such as the Coro-Flo pump series. The patented vapor elimination system keeps liquefied gas pumps primed to increase system reliability and decrease pump and seal wear. The B166B is a smooth operating bypass with moderate pressure buildup. Applications Used with all cylinder filling pumps. (Coro-Flo Models and low flow side channel pumps).

B166

T166 (11/4” and 11/2”) Pump Flow Control Valve The T166 valve provides smooth-acting flow control. Specifically designed for bypass protection for pumps in the 30–100 GPM (6.8–22.7 m3/hr) range, such as those used on delivery trucks. In contrast to the B177, the T166 valve opens gradually as pressure builds up to modulate the flow, bypassing the excess capacity smoothly and silently back to the supply tank. A continuous internal bleed in this valve assists in eliminating vapors. Applications Used with large capacity pumps filling various sizes of tanks and bottles such as those used with delivery trucks or multi-spot cylinder-filling plants.

B177 (2” and 21/2”) Differential Bypass Valve The B177 is a low-pressure buildup valve specifically designed for applications requiring protection for positive displacement pumps in the 50–350 GPM (11.4–79.5 m3/hr) for smooth-acting flow control. To properly function, this valve requires a pressure sensing line for the storage tank. This valve should be applied where horsepower is limited and accuracy set points and flow points are necessary. Applications Used in liquefied-gas bulk plant installations for the loading and unloading pumps. B177

194

Gas Equipment Catalog

victormfg.com


SECTION

9

Electric Motors Explosion Proof TEFC (IP54) UL and CSA Approved The WEG line of World Energy Guardian TM Motors are specifically designed to meet or exceed ALL APACT requirements for energy efficiency.

Standard Features: • 3 phase, 60 Hz, 208-230/460,460 or 575 V. • 143T up to 586/7 cast iron frame. • Squirrel cage rotor/Aluminum die cast. • Enclosure TEFS (IP54). • All motors supplied with ball bearings except roller bearings in drive end for frames 404T and up, in IV, VI, and VII pole. • Class “F” insulation. • Temperature rise: Class “B” (80°C). • Service factor: 1.15 (see electrical data for exceptions). • Dimensions according to NEMA standard. • NEMA ratings design “B” (except 900RPM Design “A”). • Continuous duty (S1). • 104°F (40°C) ambient temperature.

pumps/compressors

mFR# description webb# MTR00218XP3E245T HP 2 XProof 3 Phase 1800 RPM Motor 318199 206666 MTR00718XP3E213T Motor 71/2 HP 1800 RPM 3PH 208V MTR0108XP3E215T 10 HP 1800 RPM 3PH XProof Motor 183302 MTR01518XP3E254T #15 HP 3 Phase 1800 RPM X PR 254T FR — MTR02018XP3E256T #20 HP 3 Phase 1800 RPM EXP. Proof — MTR02518XP3E284T #25 HP 3 Phase 208V RPM 284T M —

9 Nema Frames 14 3T 14 5T 18 2T 18 4T 21 3T 21 5T 25 4T 25 6T

Mounting 2E 5.500 7.750 8.500 10.000

2f 4.000 5.000

h 0.344

4.500 5.500 5.500

10.000

A

2.250

6.457

2.750

8.661

3.500

9.764

0.406

7.000 8.252

ba

0.531

4.250

12.126

B

c

5.157

12.760

6.142

13.752

5.945

14.862

6.969

15.862

7.402

17.952

8.898

19.450

10.000

23.175

11.732

24.929

D

G

J

k

o

p

t

3.500

0.429

1.496

1.654

7.000

7.000

4.500

0.787

1.890

1.969

9.421

8.909

5.250

0.827

2.008

2.185

11.156

10.709

6.250

0.817

2.520

2.559

12.352

12.224

1.772

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

2.087

195


SECTION

9

Electric Motors Explosion Proof TEFC (IP54)

Nema Frames 14 3T 14 5T 18 2T 18 4T 21 3T 21 5T 25 4T 25 6T

keyway width

depth

key length

0.187

0.093

1.375

(continued)

Shaft Extension

bearings

n-w

u

ab

2.250

0.875

6.811

aa

d1

DE

od.e

6205-ZZ

6204-ZZ

6307-ZZ

6206-ZZ

NPT 3/4” 0.250

0.125

1.750

2.750

1.125

8.240 A4

0.313

0.156

2.375

3.375

1.375

9.252

NPT 1”

6308-ZZ

6207-ZZ

0.375

0.187

2.875

4.000

1.625

11.063

NPT 11/2”

6309-C3

6209-ZOC3

Victor/F.w. Webb stocks rinnai space heaters. we can also help you correctly size them with a building heat loss!

196

Gas Equipment Catalog

victormfg.com


SECTION

9

Repair Parts

Parts Details for Models C9 to C14

O-Ring Code

1

2

3 4

5

6

Buna-N

B

Neoprene ® 1

E

Teflon ® 1

MFR# 7001-031NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 10142 1014-12 2-246 2-247E2 1003-096 1003-06 1003-26 1003-36 1003-46 1003-56 113-CX_3 113-CXA 113-CXB 113-CXD 113-CXE 1004-1X 2, 3

1004-11X 7

1004-2X 1004-21X 1013

8

1013-1

Description

Qty Webb#

Ref#

MFR#

Description

9

2-224_3

Housing O-Ring

1

10

3442

Pipe Plug, 1/4” NPT

1

11

3444

Pipe Plug, 3/4” NPT

1

12

1002-09 1002-0 1002-2 1002-3 1002-4 1002-5

Case—Model 9 Case—Model 10 Case—Model 12 Case—Model 13 Case—Model 14 Case—Model 15

1 1 1 1 1 1

— — — — — —

1914-1 7012006SF019E 7002037NC087A 1015

Nameplate

1

Phillips Head Screw 6 – 32X1/4”

2

Socket Head Cap Screw

8

Adapter Ring

1

Woodruff Key, Steel Woodruff Key, SS Motor 3/4 HP Models 9, 10 Motor 1 HP Model 12 Motor 3 HP Models 14, 15 Motor 3/4 HP, Obsolete Models 9E, 10 Motor 11/2 HP, Obselete Model 12E Motor 2 HP Model 13

1 1 1 1 1 1

— — 181167 181168 — —

1

1

Hex Head Cap Screw

8

Cover—Model 9 Cover—Model 10 Cover—Model 12 Cover—Model 13 Cover—Model 14 Cover—Model 15 Case Clearance Shim (.002” Red) Case Clearance Shim (.003” Green) Case O-Ring (Non-Teflon®1) Case O-Ring Teflon®1 Impeller, Brass—Model 9 Impeller, Brass—Model 10 Impeller, Brass—Model 12 Impeller, Brass—Model 13 Impeller, Brass—Model 14 Impeller, Brass—Model 15 Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Housing Adjustment Shim (0.010”) Housing Adjustment Shim (0.020”)

1 1 1 1 1 1 As Req. As Req. 1 1 1 1 1 1 1 1 1 1 1 1 1 1

— — — — — — 181071 —

13

— — — 181060 181062 181063 181064 — — 181075 181076 181077 181057 310362

14

1

1

1

As Req. As Req.

181069 —

15 16 17

18

2497 2497-1 2555 2556 25575 28955 28965 4261

1

3 4 5 6 2

4

Qty Webb# —

Registered trademarks of the DuPont Company. Included with seal assembly/repair kit 113-CX_. _Denotes O-Ring Code. Prior to S.N. PR166727 motor part number was 3760. Starting with S.N. PW168290 will be new motor frame size. Add a 1 to # for iron or a 2 for stainless steel (example: model 10 with iron is 1003-01).

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

197

pumps/compressors

Ref#

A

9


SECTION

9

Repair Parts Parts Details for Models F9C to F15C, FF9 to FF15C and F109 to F115

O-Ring Code

Ref# 1

2

3 4

5

6

A

Buna-N

B

Neoprene ® 1

D

Vitron ® 1

E

Teflon ® 1

G

Ethylene Propylene ® 1

K

Kalrez ® 1

MFR# 7001031NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 10142 1014-12 2-246 2, 3 2-247E2 1003-094 1003-04 1003-24 1003-34 1003-44 1003-54 113-CX_3 113-CXA 113-CXB 113-CXD 113-CXE 1004-1X 1004-11X

7

1004-2X 1004-21X 1013

8 9 10 11

198

1013-1 2-224_3 3442 3444

Description

Qty Webb#

Ref#

MFR#

Description

12

1002-09 1002-0 1002-2 1002-3 1002-4 1002-5 4206-09 4206-0 4206-2 4206-3 4206-4 4206-5

Case—Model 9 Case—Model 10 Case—Model 12 Case—Model 13 Case—Model 14 Case—Model 15 Case—ANSI Flanged Model 9 Case—ANSI Flanged Model 10 Case—ANSI Flanged Model 12 Case—ANSI Flanged Model 13 Case—ANSI Flanged Model 14 Case—ANSI Flanged Model 15

Qty Webb# 1 1 1 1 1 1 1 1 1 1 1 1

— — — — — — — — — — — —

1914-1 Nameplate 7012Phillips Head Screw 6 – 32X1/4” 006SF019E 5002-281 Bearing Retainer Ring

1

2

1

Hex Head Cap Screw

8

Cover—Model 9 Cover—Model 10 Cover—Model 12 Cover—Model 13 Cover—Model 14 Cover—Model 15 Case Clearance Shim (.002 Red) Case Clearance Shim (.003 Green) Case O-Ring (Non-Teflon®1) Case O-Ring Teflon®1 Impeller—Model 9 Impeller—Model 10 Impeller—Model 12 Impeller—Model 13 Impeller—Model 14 Impeller—Model 15 Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Housing Adjustment Shim (0.010) Housing Adjustment Shim (0.020) O-Ring (Housing) Pipe Plug, 1/4” Pipe Plug, 3/4”

1 1 1 1 1 1 As Req. As Req. 1 1 1 1 1 1 1 1 1 1 1 1 1 1

— — — — — — 181071

— — — 181060 181062 181063 181064 — — 181075 181076 181077 181057 310362

1

23

3226

Key

1

1

24

2759

Ball Bearing

1

181177

1

25

Frame

1

As Req. As Req. 1 1 1

181069

Socket Head Screw

4

27

1010-2 7002037NC087A 2158

Grease Zerk

2

28

2159

Lubricap

2

— 13 14 15

Gas Equipment Catalog

1238

Bearing Cap

1

17

1006

Grease Seal

1

181067

18

5102-118

Bearing Retainer Ring

1

19

2758

Ball Bearing

1

181176

20

5000-281 24972 2497-12 1234 1234-1

Bearing Retainer Ring #5 Woodruff Key, Steel #5 Woodruff Key, SS Shaft Shaft, Stainless Steel

1 1 1 1 1

21 22

26

— — — —

16

1

3 4 5 6 2

— 181091 —

Registered trademarks of the DuPont Company. Included with seal assembly/repair kit 113-CX_. _Denotes O-Ring Code. Prior to S.N. PR166727 motor part number was 3760. Starting with S.N. PW168290 will be new motor frame size. Add a 1 to # for iron or a 2 for stainless steel (example: model 10 with iron is 1003-01).

victormfg.com


SECTION

9

Repair Parts

Parts Details For Stationary Coro-Vane® Pumps Models 521 and 1021

pumps/compressors

9

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

199


SECTION

9

Repair Parts Parts Details For Stationary Coro-Vane® Pumps Models 521 and 1021 (continued) Ref#

MFR#

Description

1162-2 1201-2 2832 2841 1172-2.53 1172-23 1206-34 2-234_2, a 2-245_2 2-249_2

Cam (521) Cam (1021) Case (521) Case (1021) 2.5” Flange (521) 2” Flange (521) 3” Flange (1021) Flange O-Ring (521) Flange O-Ring 3” (1021) Flange O-Ring 4” (1021)

1 1 1 1 1 1 2 2 2 2

181078 181086 — — — — — 181148 — —

5

2-112_2

Adjusting Screw O-Ring

1

6

2590

Flush Seal Plug 1/8” NPT

1

7

2252

Relief Valve Adjusting Screw

1

1 1 1 1 1 1 1 1 1 1 1 1 10 10 1 1

— — — — — — — — — — — — — 181094 — 181089

1 2 3 4

8 9 10 11 12 13 14 15

1174 Valve Cap (521) 1207 Valve Cap (1021) 1242-X Relief Valve Spring & Guide (521) 1227 Relief Valve Spring Guide (1021) Relief Valve Cap O-Ring (521) 2-224_2 2-228_2 Relief Valve Cap O-Ring (1021) 1241 Relief Valve (521) 1224 Relief Valve (1021) 1242 Relief Valve Spring (521) 1226 Relief Valve Spring (1021) 1170 Cam Key (521) 1309 Cam Key (1021) 1168-7 Blade (521) 1308-9 Blade (1021) 116-1X1R Rotor & Shaft Assembly (521) 1208-1X1R Rotor & Shaft Assembly (1021)

Qty Webb#

Ref#

MFR#

Description Hex Head Bolt 5/16 – 18X1 – 1/4 (521) Hex Head Bolt 3/8 – 16X1 – 1/4 (1021) Hex Head Bolt 3/8 – 16X1 – 1/4 (521) Hex Head Bolt 3/8 – 16X1 – 1/4 (1021)

37

7001-031 NC125A 7001-037 NC125A 7001-037 NC125A 7001-037 NC125A 7001-037 NC150A ———5

38

———5

39

2-227_2

40 41

34

35 36

42

4

4

28

32

Hex Head Bolt 3/8 – 16X1 – 1/2

8

Retainer

2

Seal Seat

2

Seal Seat O-Ring

2

2159

Lubricant #2

2

1359 7003-004 DR0198

Lubricant Instruction Tag Round Head Plated Drive Screw 4X3/16

2

2

Seal assemblies are available in two forms: a. Complete seal kit including bearing housing, seat adapter plate, bearings, retainer ring, seal and O-Rings. Part number 1769-X_2. b. Field replacement seal assembly containing only the seal and O-Rings. Part number 1769-XR_2. 1

_denotes O-Ring code

2

O-Ring Code

16

1358

Grease Seal

2

A

Buna-N

17

1164-1

Bearing Cap

2

B

Neoprene ® 6

D

Vitron ® 6

E

Teflon ® 6

18

2158

Grease Zerk 1/8” NPT

2

19

1769

Bearing Housing

2

20

1343

Relief Fitting (Seal Vent)

2

1769-X_1, 2, a 1769-XR_1,2,a 1163-28 1209-18 1161-4 1205-4 2754-X 2755 2754

Seal Assembly Seal Assembly—Replacement Sideplate (521) Sideplate (1021) Head (521) Head (1021) Roller Bearing—Complete Bearing Inner Race Bearing Outer Race

2 2 2 2 2 2 2 2 2

181126 181127 — — — — — — —

21 22 23 24

Optional flanges, (model 521): 1172-1.5 1/2” NPT 1172-1.5S 1/2” Weld 1172-2 2” NPT 1172-2S 2’ Weld 1172-2.5 21/2” NPT 1172.2.5S 2 1/2” Weld

3

25

2760-244

Retainer Ring

2

26

1343

Relief Fitting (Grease)

2

27

2-128_7

Shaft O-Ring

2

28

1882

Seal Adapter Plate

2

29

2-240_2

Adapter Plate O-Ring

2

Optional flanges, (model 1021): 1206-3S 3” Weld 1206-4 4” NPT 1206-4S 4’ Weld

5

30

2-261_ 2-268_2

Case O-Ring (521) Case O-Ring (1021)

2 2

181153 —

31

2270

1/4” Key

2

32

2949

Nameplate

1

7

33

3442

1/4” NPT Plug

1

8

200

2, a

Gas Equipment Catalog

Qty Webb#

4

Not available separately.

Neoprene®, Viton®, and Teflon® are registered trademarks of the Dupont company. 6

Available in Buna-N only. Sideplate replacement instructions. victormfg.com


SECTION

9

Repair Parts

Parts Details For Models Z/ZH3200 28 (60 ft•lb) 25 (25 ft•lb) 22 12 4

Inlet

4

29 (15 ft•lb) 28 (60 ft•lb)

O-Ring Code Buna-N

B

Neoprene ® 1

D

Vitron ® 1

Note: Hydraulic motor is not shown.

E

Teflon

See repair/re-build kits.

Outlet (25 ft•lb)

®1

CAUTION: Always relieve pressure in the unit before attempting any repairs.

MFR#

Description

1

4495-X2R

Rotor Shaft Assembly

1

2

4242

Cam

3

4232

Vane5

1

3 4 6

Qty Webb#

Ref#

MFR#

Description

22

2-262_

O-Ring—Case4

2

1

181217

23

2-224_

O-Ring_Relief Valve Cap4

1

6

254235

24

Relief Valve Spring

1

25

1240 7001037NC150A 2158

Bolt—3/8 – 16X11/2” Hex Head

16

1/8” NPT Grease Zerk

2

1/8” NPT Relief Fitting

4

Bolt—1/2 – 13X11/2” Hex Head

16

Bolt—5/16 – 16X11/4” Hex Head

4

4

4231

Sideplate

2

5

4488

Head

2

6

4239

Case

1

7

4417

Bearing Cap

2

8

4438

Grease Seal

2

26 27

Qty Webb# —

9

4435

Mounting Ring

2

Bearing Shim (.002) Red Bearing Shim (.010) Brown Bearing Shim (.020) Yellow

29

10

4439 4439-1 4439-2

As Req.

— — —

30

1343 7001050NC150A 7001031NC125A 1241

Relief Valve

1

31

4243

Outlet Flange—2” NPT Ell2

1

11

2270

Shaft Key

2

32

4241

Cam Key

1

12

4431-X_a, 2

Mech. Seal Assembly4

2

254236

33

3253

Cam Key Pin

1

28

13

2754

Bearing Outer Race

2

34

3442

1/4” NPT Pipe Plug

1

14

4432

Thrust Bearing Assembly

2

35

4262-X

Vane Driver

3

254237

15

2760-244

Retainer Ring

2

36

2-234_

O-Ring—Flange4

1

16

1174-2

Relief Valve Cap

1

37

2159

Lubricap

2

17

1359

Lubrication Instruction Plate

2

38

1172-2

Aux. Inlet Flange—2” NPT3

1

181084

18

Grease Seal

2

39

2649

Nameplate

1

4248

Relief Valve Nameplate

21

1 As Req. 8

20

4441 7012006SF019E —

Screw

8

40

Not Shown

41

4282

Relief Valve Shim

Not Shown

42

7206-037A

3/8” Lockwasher

— —

Registered trademarks of the DuPont Company. Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), 2” NPT (1172-2) and 1.5” NPT EII (1942). Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), blind (1920-3) and 2” NPT EII (4243). _denotes O-Ring code. See chart above. Slots in varies must face TOWARDS the direction of rotation.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

201

pumps/compressors

Ref#

19

2

A

9


SECTION

9

Repair Parts Parts Details For Models Z3500

O-Ring Code Buna-N

B

Neoprene ® 1

D

Vitron ® 1

Note: Hydraulic motor is not shown.

E

Teflon

See repair/re-build kits.

®1

CAUTION: Always relieve pressure in the unit before attempting any repairs.

Ref#

MFR#

Description

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

2-228 2-245 2-259 2-268 1206-4 1207-2 1208-1X6R 1224 1309 1343 1359 2158 2159 2270 2649 2754 2760-244 3253 3442 3935 3936 4248 4417 4432

O-Ring4 O-Ring4 O-Ring4 O-Ring4 Inlet Flange—3” NPT2 Relief Valve Cap Rotor Shaft Assembly Relief Valve Cam Key Grease Relief Fitting Lubrication Plate Grease Zerk Lubricap Shaft Key — 1/4” Nameplate Outer Bearing Retainer Ring Cam Key Pin Pipe Plug—1/4” NPT Sideplate Vane5 Relief Valve Warning Tag Bearing Cap Thrust Bearing Assembly

1

3 4 6 2

A

Qty Webb# 1 1 1 2 1 1 1 1 1 4 2 2 2 1 1 2 2 2 2 2 6 1 2 2

— — — — — — 181089 — — — — — — — — — — — — — — — — —

Ref#

MFR#

Description

25 26 27 28 29 30 31 32

Thrust Bearing Mounting Ring Greas Seal/Oil Seal Bearing Cap Shim—0.002” Bearing Cap Shim—0.010” Bearing Cap Shim—0.020” Grease Seal Mechanical Seal Assembly4 Coro-Vane Shaft Cover

2 2 2 2 2 2 2 1

— — — — — — — —

Hex Head Bolt

24

Hex Head Bolt

18

Hex Head Bolt

4

Screw

9

Screw

2

38 39 40 41

4435 4438 4439 4439-1 4439-2 4441 4431-X2 4985 7001037NC125A 7001037NC150A 7001037NC175A 7012006SF019E 7012010SF050E 7206-037A 5534 5537 5539

Lock Washer—0.375” Head Case Cam

8 2 1 1

— — — —

42

5538

Outlet Flange—3” NPT Elongated3

1

43 44

5548 5554-X

Spring Vane Driver

1 6

— —

33 34 35 36 37

Qty Webb#

Registered trademarks of the DuPont Company. Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), 2” NPT (1172-2) and 1.5” NPT EII (1942). Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), blind (1920-3) and 2” NPT EII (4243). _denotes O-Ring code. See chart above. Slots in varies must face TOWARDS the direction of rotation.

202

Gas Equipment Catalog

victormfg.com


SECTION

9

Repair Parts

Repair Kits and Spare Parts For Stationary Coro-Vane® Pumps C51/F51 Standard Repair Kits (no kit available) MFR# 2296-1X_5 2451-2 2-154_ 2491

Description Seal Assembly Vane Case O-Ring Sideplate

C51/F51 Additional Spare Parts

Qty Webb# 1 8 2 2

— — — —

521 Repair Kit 2904-X21 Description Sideplate Vane Grease Seal Seal Assembly (Replacement) O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N Flange Gasket Grease Seal, Thrust Roller Bearing

Description Sideplate Vane Grease Seal Seal Assembly (Replacement) O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N Grease Seal, Thrust Roller Bearing

Qty Webb# 2 10 2 2 1 1 181179 2 2 2 3 1 2

1358 1769-XRA 2-234A 2-238A 2-245A 2-249A 2-268A 2014 2754 3209 3476-L 3476-R 3477

Description Grease Seal Seal Assembly (Replacement) O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N Grease Seal, Thrust Bearing Outer Race Ball Bearing Sideplate, Left Sideplate, Right Vane

Rotor & Shaft Assembly Roller Bearing

1 2

— —

MFR# 1166-1X1R 1162-2

Description

Qty Webb#

Rotor & Shaft Assembly Cam (Liner)

1 1

— 181078

1021/F1021 Additional Spare Parts

Qty Webb# 2 10 2 2 1 1 181182 2 2 2 1 2

MFR# 1208-1X1R 1201-2

Description

Qty Webb#

Rotor & Shaft Assembly Cam (Liner)

1 1

181089 181086

9

F1521 Additional Spare Parts

F1521 Repair Kit 2907-X31 MFR#

2492-X 2471

Qty Webb#

521 Additional Spare Parts

1021/F1021 Repair Kit 2906-X2 MFR# 1209-1 1308-9 1358 1769-XRA 2-112A 2-228A 2-245A 2-249A 2-268A 2014 2754-X

Description

Qty Webb# 2 2 3 1 1 1 2 1 2 1 1 1 6

— — — — — — — — — — — — —

MFR# 3350-X1R 1792-1

Description Rotor & Shaft Assembly Cam (Liner)

Qty Webb# 1 1

— —

1 All repair kits have Buna-N O-Rings which are suitable for both LPG and NH3 applications.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

pumps/compressors

MFR# 1163-2 1168-7 1358 1769-XRA 2-112A 2-224A 2-227A 2-234A 2-261A 2010 2014 2754-X

MFR#

203


SECTION

9

Repair Parts Repair/Re-build Kits Z2000, ZH2000, ZX2000, ZXH2000 Repair Kit 3193-X1 MFR# 2-224A 2-231A 2754-X 4262-X 4428 4431-XA2 4432 4435 4439 4439-1 4439-2 4441 2270

Description O-Ring, Buna-N O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key

Qty Webb# 1 2 2 3 6 2 2 2 8 2 2 2 1

— — — — — — — — — — — — —

Z3200, ZH3200 Repair Kit 3195-X1 MFR# 2-224A 2-234A 2754-X 4262-X 4232 4431-XA2 4432 4435 4439 4439-1 4439-2 4441 2270

Description O-Ring, Buna-N O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key

Qty Webb# 1 2 2 3 6 2 2 181237 2 8 2 2 2 1

2-228A 2754-X 5554-X 3936 4431-XA2 4432 4435 4439 4439-1 4439-2 4441 2270

Description O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key

MFR# 2-231A 2-234A 4460-X 4449-X 4448 4464-XA2 4453 4454 4458 4458-1 4458-2 4463 4459

Qty Webb# 2 2 3 6 2 2 2 8 2 2 2 1

— — — — — — — — — — — —

MFR# 4414 4427

204

Gas Equipment Catalog

O-Ring, Buna-N O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key

Qty Webb# 1 2 2 5 6 2 2 2 8 2 2 2 1

— — — — — — — — — — — — —

Description Cam Sideplate

Qty Webb# 1 2

— —

Z3200, ZH3200 Re-Build Kit 3196-X1 includes all items in the Whole Kits Repair Kit (#181238)plus the following: MFR#

Description Cam Sideplate

Qty Webb# 1 2

181217

Z3500 Re-Build Kit 3196-X2 includes all items in the Repair Kit plus the following: MFR# 5539 3935

Description Cam Sideplate

Qty Webb# 1 2

— —

Z4200, ZH4200, Z4500 Re-Build Kit 3198-X1 includes all items in the Repair Kit plus the following: MFR#

1 All repair kits have Buna-N O-Rings which are suitable for both LPG and NH3 applications.

Description

Z2000, ZH2000, ZX2000, ZXH2000 Re-Build Kit 3194-X1 includes all items in the Repair Kit plus the following:

4242 4231

Z3500 Repair Kit 3195-X2 MFR#

Z4200, ZH4200, Z4500 Repair Kit 3197-X1

4443 4446

Description Cam Sideplate

Qty Webb# 1 2

— —

victormfg.com


SECTION

10

Generators Guardian® Series Standby Generators The G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing. Features: • True Power electrical technology • Two line LCD Tri-lingual digital Nexus controller • Electronic governor • External main circuit breaker and system status LED indicators 14KW Steel

20KW Aluminum

• Flexible fuel line connector • Composite mounting pad • Natural gas or LP gas operation • 3 Year limited warranty • UL 2200 listed

Generac Whole-House Propane / Natural Gas Generators MFR# GRC5882 GRC5883 GRC5884 GRC5885 GRC5886 GRC5887 GRCQT02516

DESCRIPTION AIR CLD GENERATOR 8KW STEEL AIR CLD GENERATOR 10KW STEEL AIR CLD GENERATOR 14KW STEEL AIR CLD GENERATOR 17KW STEEL AIR CLD GENERATOR 17KW ALUM AIR CLD GENERATOR 20KW ALUM LIQ COOLED GENERATOR 25KW STEEL

WEBB# 361729 361730 422548 361732 422549 422550 361734

Generac Load Centers DESCRIPTION 10-CIRC LOAD CENTER ATS NEMA 1 12-CIRC LOAD CENTER ATS NEMA 1 14-CIRC LOAD CENTER ATS - NEMA 1 16-CIRC LOAD CENTER ATS NEMA1 100 AMP SERV ENTR 120/240 1 NEMA 3R 200 AMP SERV ENTR 120/240 1 NEMA 3R 100 AMP 120/240 1 NEMA 3R 200 AMP 120/240 1 NEMA 3R 100 AMP 120/208 3 NEMA 3R 200 AMP 120/208 3 NEMA 3R 200 AMP 120/240 3 NEMA 3R PWR MGR 200A AMP 120/240 1 NEMA 3R

WEBB# 361743 361744 422564 361745 368691 361746 422567 422571 422568 422572 422573 422566

Misc Equipment

MFR# GRCRTS10EZA1 GRCRTS12EZA1 GRCRTS14EZA1 GRCRTS16EZA1 GRCRTSD100A3 GRCRTSD200A3 GRCRTSN100A3 GRCRTSX200A3 GRCRTSN100G3 GRCRTSN200G3 GRCRTSN200J3 GRCRTSS200A3

10 Generac Portable Gasoline Generators MFR# GRC5793 GRC5939 GRC5940

DESCRIPTION IX2000 PORT GEN 2000 WATTS GP5500 PORT GEN 5500 WATTS GP6500 PORT GEN 6500 WATTS

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

WEBB# 422562 422552 422553

205


SECTION

10

Generators ETQ Generators MFR# IN1800I TG32P12 TG72K12 TP30P11 PG60B12 W0001-T40-00

DESCRIPTION 1800W CLOSED FRAME GASOLINE 4000W OPEN FRAME GASOLINE 8250W OPEN FRAME GASOLINE 3500W OPEN FRAME LP 7000W OPEN FRAME LP WHEEL KIT FOR TP30P11

IN1800I

TG32P12

WEBB# 411953 411954 420781 411955 435132 415973

TP30P11

TG72K12

PG60B12

Generator Usage Chart Nat gas usage (btu/hr 1000's)

LP usage gal/hr (btu/hr 1000's)

Air cooled

Half load

Half load

Half load

7 KW

66

119

.82 (75)

1.47 (135)

10 KW

102

156

1.25 (115)

1.93 (178)

13 KW

156

220

1.55 (143)

2.18 (200)

16 KW

173

245

1.59 (147)

2.51 (231)

18 KW

181

262

1.97 (182)

2.85 (262)

Nat gas usage (btu/hr 1000's)

Half load

LP usage gal/hr / (btu/hr 1000's)

Liquid cooled

Exercise

Half load

Full load

18 KW

48

165

278

.52 (48)

1.8 (166)

3.04 (280)

20 KW

60

188

315

.65 (60)

2.05 (189)

3.44 (317)

25 KW

60

253

437

.65 (60)

2.77 (255)

4.81 (443)

30 KW

56

281

437

.65 (60)

3.17 (293)

5.0 (461)

45 KW

102

373

720

1.11 (102)

4.07 (375)

7.86 (723)

60 KW

123

500

960

1.34 (124)

5.46 (503)

10.48 (965)

70 KW

110

499

1020

1.20 (111)

5.46 (503)

11.17 (1028)

80 KW

131

600

1154

1.45 (134)

6.64 (611)

12.78 (1176)

100 KW

140

713

1374

1.53 (141)

7.81 (719)

15.05 (1385)

130 KW

135

927

1786

1.48 (137)

10.15 (934)

19.56 (1800)

150 KW

155

1070

2061

1.70 (157)

11.72 (1079)

22.57 (2077)

206

Gas Equipment Catalog

Exercise

Half load

Full load

victormfg.com


SECTION

10

Gas Burner G3B Power Gas Burner 60K - 180K BTU

The G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing. Features: • Converts from propane to natural gas with just an orifice change— no conversion kit needed. • Factory-packaged with combustion control and gas fuel train. • 60,000 to 180,000 Btuh­—ideal for small to large homes. • Quiet and clean. • Dependable, hot surface ignition for quick, clean light-off. • Compact, efficient flame pattern. • Does not require a refractory liner—fires with or without a combustion chamber. • Ideal for high-efficiency wet-based boilers. • Superior for use in 2, 3, 4 or 5-section boilers. • Calibrated air throttle for easy adjustment. • Universal mounting flange. • Low-energy motor—only 0.40 amp. • Includes 1-year warranty. mfr# description webb# 74245 G3B With 6” Tube 185221 74252 G3B With 9” Tube 95235

EZ-Gas Power Gas Burner 50K - 275K BTU

mfr# description webb# 9859210AFR1A EZ-Gas 10” A 150K - 275K 379487 9859210BFR1 EZ-Gas 10” B 50K - 175K 379488

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

207

Misc Equipment

Features: • Converts from propane to natural gas with just an orifice change— no conversion kit needed. • Fires negative or positive chambers from 50,000 to 275,000 Btuh input. • Provides dependable, direct-spark ignition of main flame—for quick, clean light offs. • Comes standard with time-tested solid state ignition and state-of-the-art microprocessor control technology. • Factory-packaged with combustion control and gas fuel train. • Shipped completely assembled and wired—for “EZ” installation and start-up. • Diagnostic LED lights annunciated operating mode: Self-check, Flame-on, Recycle, Lockout and Latch-up. • High-efficiency, compact flame pattern design ensures clean, quiet operation. • Does not require a refractory liner—fires with or without a combustion chamber. • Available with custom welded air tube flange (and/or optional pedestal) to accommodate most appliance mounting requirements. • Includes 1-year warranty.

10


SECTION

10

Vaporizers Direct Fired LPG Vaporizers

A propane vaporizer is actually a boiler. Instead of boiling water, it boils propane. It may sound strange that heat is required to vaporize propane when propane will boil at -44 F, but, when propane vaporizes by expansion alone, it causes a refrigeration action. In applications with high propane demand, the uncontrolled vaporization would freeze valves and burner nozzles. Therefore, heat is required to offset the refrigeration action. Direct fired vaporizers use a portion of the propane they vaporize to supply the heat for the vaporization process. AES direct fired vaporizers can be used to vaporize all forms of LPG (Liquefied Petroleum Gas), including Propane, Butane, Propylene, etc. • For Propane, Butane, & other LPG • Two-Stage Burner • Dual Liquid Level Control • Piezo Ignitor mfr# ALT1206H ALT4040H ALT8040H

WEBB# 424131 424133 424132

Capacity 120 gal/hr (10.9 MBH) 40 gal/hr (3.6 MBH) 80 gal/hr (7.3 MBH)

Comparative Thermal Value of Fuels Natural Gas.........................................................100,000 BTU’s =1 Therm Fuel Oil...............................................................42 Gallons = 1 barrel Gas Conversion Factors 1 Cubic Foot (CF)................................................Approximate 1,000 BTU’s 100 CF.................................................................100,000 BTU’s 1 Therm..............................................................100,000 BTU’s 10 Therms...........................................................1 Decartherm (DTH) 1 DTH.................................................................1,000,000 BTU’s 1 DTH.................................................................1 MM BTU Approximate Conversion Propane/Gallon..................................................91,500 BTU’s = .915 Therms/Gallon Butane/Gallon....................................................103,000 BTU’s = 1.03 Therms/Gallon #2 Heating Oil/Diesel/Gallon...........................138,500 BTU’s = 1.385 Therms/Gallon #6 Fuel Oil/Barrel..............................................6,350,000 BTU’s = 63.5 Therms/Gallon Coal (Short Ton).................................................21,900,000 BTU’s = 219 Therms/Short Ton 1 Truck & Trailer of Propane (9,300 Gallons) = 8,510 Therms 1 Truck & Trailer of Butane (9,300 Gallons) = 9,274 Therms 1 Truck & Trailer of Diesel (8,000 Gallons) = 11,080 Therms 1 Truck & Trailer of #6 Fuel (7,000 Gallons) = 10,500 Therms Convert Cents/Gallon to $/MM BTU Multiply Cents/Gallon by: Ethane.................................................................15.24 Gallons/MM BTU Propane...............................................................10.93 Gallons/MM BTU Normal Butane...................................................9.71 Gallons/MM BTU Iso-Butane...........................................................10.12 Gallons/MM BTU Mixed Butane (75/25).........................................9.81 Gallons/MM BTU Natural Gasoline.................................................8.00 Gallons/MM BTU #2 Oil..................................................................7.22 Gallons/MM BTU Convert $/Bbl to $/MM BTU Divide $Bbl by: #6 Oil..................................................................6.35 MM BTU/Barrel #6 Oil..................................................................151,190 MM BTU/Gallon

208

Gas Equipment Catalog

victormfg.com


10

Disconnects Hansen Gas-Mate Coupling

One-way shut-off Safety Couplings are designed for LP and natural gas applications where 3/8”, 1/2”, 3/4”, 1”, and 11/4” hose is used. 1/2 PSI Max Pressure. MFR#

Female End Conn. Dimensions Webb#

100-006 100-008 100-010 100-506 100-508 100-510

3/8” FPT, Socket Only 1/2” FPT, Socket Only 3/4” FPT, Socket Only 3/8” FPT, Plug Only 1/2” FPT, Plug Only 3/4” FPT, Plug Only

202616 182153 182146 182158 182154 182147

2.44 X 1.13 X 1.00 2.84 X 1.38 X 1.13 3.17 X 1.75 X 1.50 1.59 X 0.94 X 0.81 1.94 X 1.16 X 1.00 2.06 X 1.52 X 1.31

Burnaby Gas Outlet Box Model #G0101-5 Completely enclosed in a UV and fire protectant PVC box, manufactured to ISO 9220 standard, the gas outlet is an ideal means of safely and securely connecting your gas barbecue, patio heater, stove or dryer directly to your residential gas supply. • Eliminates refilling tanks, gas identification • Quick disconnect safety shutoff with easy access • C/W standoffs for siding installation • CGA & AGA approved for Indoor/Outdoor use • Approved for temperatures to -40° • Inlet connection – 3/8” N.P.T. • Hose connection – 3/8” Quick Disconnect • 75 MBH natural gas/118 MBH • Stainless models have lockable door To complete this installation, add: Mfr# SAE38X38MUN VCT50A1900030 VCT50A1900100 VCT50A1900101 Mfr# G0101-SS-50 GR0101-SS GR0101-SS-50 G0101-DBL-SS G0101-5W-50

6’ Hose

12’ Hose 18’ Hose

Webb#

Misc Equipment

And a hose:

Description

3/8” Female X Male Union

370042 370041 370040

Description

Webb# 283797 3/8” Recessed Mount SS 283798 1/2” Recessed Mount SS 283799 1/2” Surface Mount Double Connector 283800 191025 6” X 41/2” X 21/2”, 1/2” Surface Mount, White 1/2” Surface Mount SS

10

Gas Outlet Mfr# MXTGC10AA01

Description Plug1 Gas Outlet

Webb# 412565

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

209


SECTION

10

Gas Lights Galaxy Lights By Faulk MFR#

Description

Webb#

vct2703 vct2705 vct4globe

Single Wall Light Double Wall Light Glass Globe

316096 367629 316225

Lights Mfr# F220325 F220300 F220353 F220351 F220370 F220330

Description Light Indoor (Gray) Light Indoor (Brass) Soft Tie on Mantle Performed Mantle Chandelier Kit Glass Globe

Webb# 395850 396327 395846 395848 395849 395843

Rutland Fireplace Products Mfr# VCT304 VCT565 VCT570-6 VCT585 VCT587 VCT595 VCT63-G VCT641 VCT82 VCT83-6

210

Description Webb# CHIMNEY PAINT SS 401840 WHT OFF GLASS CLEANER 401841 GAS LOG SOOT REMOVER 401844 GLW EMBRS 12OZ TUB 433550 ROCK WOOL 401839 LAVA ROCK 401838 FIREPLACE MORTAR GRAY 408107 SEAL IT RIGHT 800F BLK LATEX 401843 FIREPLACE GLASS CLEANER 401842 BRICK & STOVE CLEANER 408108

Gas Equipment Catalog

victormfg.com


SECTION

11

Serviceman’s Tools

Leak Detector

Propane Flare

Dispenser With Brush

8 oz. Bottle & Dauber

Gallon MFR# TSTLTG4 TSTTLPINTUNLABE TSTBTL8DBRUNPRI TSTSTL16CYLUNPR

Description All Season, Gallon 16 oz. Bottle With Brush 8 oz Bottle With Dauber 16 oz. Bottle With Spray

Leak Tester Kit mfr# VCTPTK

DESCRIPTION webb# Tester Gas Kit 315690

WEBB# 184312 184310 184311 184309

• Electronic Ignition and proof of flame. • Safety feature offers automatic relight attempt — complete shutdown if unsuccessful. • Burns up to 529 gallons per hour. • Burns liquid or vapor propane. • Over 48,000,000 BTU/hr (1/2” Flare). • Flare burner stands 12’ above ground surface • 12’ power cord for 115 volt A.C. • 20’ remote switch cord. • Stable triangular base. • Setup in 5 minutes.

Available in three line sizes 1/4” • 3/8” • 1/2” MFR# PF-12 LPS PF-38 LPS PF-16 LPS

SIZE BTU/hr

Gals/hr Weight WEBB# Burns 75 100.5 lbs — 3/8” Flare 38,000,000 Burns 416 103.0 lbs — 1/2” Flare 48,300,000 Burns 529 105.5 lbs — 1/4” Flare 6,900,000

ARIBee Bopper II Wasp and Hornet Spray #61011 Beware of the wasp with an attitude. Bee Bopper II will knock him right out of the sky. With Bee Bopper II, you can spray the nest from 20 feet away. Bee Bopper II kills bees and hornets too.

Leak Detector Mfr# description webb# HER45-801 8 oz. 11293

Aim & Flame Lighters mfr# Desc. VCTAF Childproof VCTHW6T —

Webb# 184435

Webb# 184412 266447

Test Gauge Kit

Match Lighter Mfr# Z6-413

Webb# 193250

Tools & Chemicals

Mfr# Size VCT61011 14 oz.

11 mfr# PIGME295-1 VCT18SHVLV VCTPTG RIT00706

Description

1/8” MPOL X FPOL, No Plug 1/8” Union MPT Half

Pressure Test Gauge (0 – 300#) Hose Only

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

Webb# 303222 430102 394983 379916

211


SECTION

11

Serviceman’s Tools Low Pressure Test Set

This kit provides the equipment necessary for checking regulator delivery pressure (low pressure) at the appliances. The basic set contains a 2434A-2 low pressure gauge and a 3 foot — 3/16” O.D. flexible synthetic rubber tube. Adapters are also available. 2962

mfr# EM150 EM200

EM150

EM200

Features: • Measures postitive and negative pressure 20” water gauge. • Auto power off. • Rubber-boot with built-in magnet. • .05” resolution below 9.95”.

Features: • Dual scale: 60” water gauge and 150 mBar .01” wg resolution below 9.99”. • Ruggedized with sturdy metal fittings. • Rubber-boot with built-in magnet. • Min/Max. • Data hold. • Auto power off. • Back-lit display. • One year limited warranty. EM200

2434A

EM150

1212 KIT MFR#

Description

Webb#

2434A

Test Kit

162825

SJIGPTK

Test Kit

204982

1328

3/8” OD Adapter

162816

1331

1/2” OD Adapter

162817

1332

5/8” OD Adapter

162818

High Pressure Gauge Adapter

Inlet Outlet MFR# Connection connection 2962

Soft Nose M. POL

F. POL

Webb#

0 to 300

162829

The water manometer kit is especially suited for use with low pressure LP-Gas systems. It is ideal for pressure checks downstream of the low pressure regulator and at the appliances. Description

Webb#

Flexible Tube Water Manometer Kit

162815

MFR#

Description

Webb#

DWY1222-16

U Tube Manometer

185267

1212 KIT

Dwyer

212

Description

Webb#

DWY2030

0-30” Magnehelic Differential Gauge

2251109

DWYA432

Carry Case/Hoses for 2030 Gauges

359347

Quick Look 72

Pressure Gauge Range (PSIG)

Water Manometer Kit

MFR#

Series 2000 Magnehelic Differential Presssure Gauge MFR#

Designed for testing high pressure lines. Adapter has 0 to 300 PSIG gauge. A bleeder valve allows you to bleed down to correct pressure during pressure tests.

Webb# 193481 284231

Gas Equipment Catalog

mfr# 720001W

Webb# 360275

MetroTel Corp Cable Hound DSP

The Cable Hound DSP is an electronic device designed to accurately locate and determine depth of buried cable or metallic pipe. Features: • Improved depth and distance capabilities. • New receiver with digital signal processing (DSP). • Auto-Off switch saves battery life. • Quality padded headphones included. • Improved, more convenient case. mfr# MT99-0118

Webb# 308931

victormfg.com


SECTION

12

LP Container Requirements

Filling Instructions for the Vacuum Pre-Purged Propane Tank CAUTION: • Do not remove seals on valves before being properly instructed on how to initially fill a vacuum pre-purged propane tank. • Do not let any air enter the propane tank. If air is allowed in the tank before the pressure is normalized, it must be re-purged with propane vapor in accordance with NFPA Pamphlet #58 and government regulatory requirements. • Do not remove cap from fill valve until the vacuum has been neutralized. Begin filling through the service valve (a/k/a the multivalve) for the first fill or at least until the vacuum is neutralized. • Do not open the outage valve until the pressure in the tank has normalized or a positive pressure has been achieved in the tank. • The presence of a vacuum in the tank does not eliminate the need for the introduction of methanol into the tank. • Never prepare the propane tank for service on a customer’s property, but always at the bulk plant site or some other safe location. 1) 2) 3) 4) 5)

Verify that a vacuum exists in the tank. Remove the seal wrap from the service valve and verify that the service valve hand wheel is tightly closed. Connect a vacuum pressure gauge to the service valve outlet connection and open the hand wheel. Visually check the vacuum pressure gauge dial for the presence of a vacuum. Close the service valve and disconnect the vacuum pressure gauge. NOTE: If the vacuum is not in accordance with NPGA Safety Bulletin No. 133-89(a), the container must be re-purged with propane vapor.

The Tank Has Now Been Prepared For Service. • To transport the tank after preparation process, remove all propane gas in the tank in excess of the amount of propane permitted to be transported under applicable regulations, including those of the U.S. Department of Transportation. • Once the tank has been safely set for service, you may continue the filling process through the fill valve by removing the seal and cap of the fill valve and using your normal safe filling procedures.

CAUTION: The initial fill must be to the maximum allowable liquid level to counteract the possible depletion of ethyl mercaptan in the tank.

• If you did not do so earlier, you may also inject methanol into the tank at this point by including an injection device in your fill line. • Future fillings should be made through the fill valve.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

appendices

6) Add methanol to the propane tank by connecting a hose to the POL outlet of the service valve. 7) Submerge the other end of the hose in a safety container that has been filled with the required measure of methanol. 8) Gradually open the service valve and the metha nol will be drawn into the tank to partially fill the vacuum that exists. 9) To prevent air from getting into the propane tank, close the service valve as soon as the measured amount of methanol has been removed from the safety container. 10) Disconnect the methanol hose from the POL of the service valve. 11) Connect the propane fill hose to the POL connector on the service valve.

12) Open the service valve and start to fill the tank with propane. CAUTION: After the tank pressure has been normalized, close the outage valve (if it was opened after the pressure was normalized), the service valve and the fill hose valve. NOTE: The appropriate amount of propane to normalize the vacuum pressure in the tank will vary depending on the volume of the tank. If liquid is used, 1 to 4 gallons of propane is required for all tanks up to 1000 gal. water capacity. If vapor is used, wait until there is no longer an audible transfer of vapor from the filler hose to the tank. 13) Bleed off the fill connector pressure and disconnect.

12 213


SECTION

12

LP Container Requirements Liquified Petroleum Gas Code* Storage Within Residential Buildings. Storage of cylinders within a residential building, including the basement or any storage area in a common basement storage area in multiple-family buildings and attached garages, shall be limited to cylinders each with a maximum water capacity of 2.7 lb (1.2kg) and shall not exceed 5.4-lb (2.4-kg) aggregate water capacity for smaller cylinders per each living space unit. Each cylinder shall meet DOT specifications. 5.4 Storage Outside of Buildings.

Location of Storage Outside of Buildings. Storage outside of buildings for cylinders awaiting use, resale, or part of a cylinder exchange point shall be located as follows. 5.4.1.1 At least 5 ft. (1.5 m) from any doorway or opening in a building frequented by the public where occupants have at least two means of egress as defined by NFPA 101, Life Safety Code. For buildings, or sections of buildings, having only one means of egress, at least 10 ft. from the doorway or opening. 5.4.1.2 At least 20 ft. from any automotive service station fuel dispenser. 5.4.1.3 In accordance with Table 5.4.1.3 with respect to the following: (1) Nearest important building or group of buildings. (2) Line of adjoining property that may be built upon. (3) Busy thoroughfares or sidewalks. (4) Line of adjoining property occupied by schools, churches, hospitals, athletic fields, or other points of public gathering. (5) Dispensing station. Exception: Cylinders in the filling process shall not be considered to be in storage.

5.4.2 Protection of Cylinders. 5.4.2.1 Cylinders at a location open to the public shall be

protected by either of the following: (1) An enclosure in accordance with 3.3.6(a) (2) A lockable ventilated metal locker or rack that prevents tampering with valves and pilferage of the cylinder.

5.4.2.2* Protection against vehicle impact shall be provided

in accordance with good engineering practice where vehicle traffic normally is expected at the location. 5.4.3 Alternate Location and Protection of Storage.

Where the provisions of 5.4.1 and 5.4.2.1 are impractical at construction sites or at buildings or structures undergoing major renovation or repairs, alternate storage of cylinders shall be acceptable to the authority having jurisdiction. 5.5* Fire Protection. Storage locations, where the aggregate quantity of propane stored is in excess of 720 lb. (327 kg), shall be provided with at least one approved portable fire extinguisher having a minimum capacity of 18 lb. (9.2 kg) dry chemical with B-C rating. The required fire extinguisher shall be located no more than 50 ft. (15 m) from the storage location. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

Use of Liquid Volume Correction Factors, Table F.3.3. F.4.1 To correct the observed volume in gallons for any LP-Gas (the specific gravity and temperature of which is known) to gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the specific gravity and temperature as described in F.3.3. (b) Multiply the gallons observed by this correction factor to obtain the gallons at 60°F (16°C). Example: A container has in it 4055 gal of LP-Gas with a specific gravity of 0.560 at a liquid temperature of 75°F. The correction factors in the 0.560 column are 0.980 at 76°F and 0.983 at 74°F, or, interpolating, 0.9815 for 75°F. The volume of liquid at 60°F is 4055 x 0.9815, or 3980 gal. F.4.2 To determine the volume in gallons of a particular LP-

Gas at temperature t to correspond with a given number of gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the LP-Gas, using the column for its specific gravity and reading the factor for temperature t. (b) Divide the number of gallons at 60°F (16°C) by thiscorrection factor to obtain the volume at temperature t.

Table 5.4.1.3 Distances from Cylinders in Storage and Exposures Quantity of LP-Gas Stored lb kg £720 £227 721 to 2,500 227+ to 1,134 2,501 to 6,000 1,134+ to 2,721 6,001 to 10,000 2,721+ to 4,540 >10,000 >4,540

214

Horizontal Distance to . . . (1) & (2) (3) & (4) (5) ft m ft m ft m 0 0 0 0 5 1.5 0 0 10 3 10 3 10 3 10 3 10 3 20 6.1 20 6.1 20 6.1 25 7.6 25 7.6 25 7.6

Gas Equipment Catalog

victormfg.com


SECTION

12

LP Container Requirements

Liquified Petroleum Gas Code* Example: It is desired to pump 800 gal (3.03 m3) at 60°F (15.5°C) into a container. The LP-Gas has a specific gravity of 0.510, and the liquid temperature is 44°F. The correction factor in the 0.510 column for 44°F is 1.025. Volume to be pumped at 44°F is 800/1.025 = 780 gal (2.95 m3).

F.5 Maximum Liquid Volume Computations. F.5.1 Maximum Liquid LP-Gas Content of a Container at Any Given Temperature. F.5.1.1 The maximum liquid LP-Gas content of any container depends on the size of the container, whether it is installed above ground or under ground, the maximum permitted filling limit, and the temperature of the liquid [see Tables 4.4.2.2(a), (b), and (c).] F.5.1.2 The maximum volume fraction Vt (in percent of container capacity) of an LP-Gas at temperature t, having a specific gravity G and a filling limit and weight percent filling limit of L, is computed by use of the following formula: or:

Vt =

L G

Vt =

L GXF

÷F

where: Vt = percent of container capacity that can be filled with liquid L = maximum permitted filling limit by weight (see Table 4.4.2.1) G = specific gravity of particular LP-Gas F = correction factor to correct volume at temperature t to 60°F (16°C) Example: The maximum liquid content, in percent of container capacity, for an aboveground 30,000-gal (114-m3) water capacity container of LP-Gas having a specific gravity of 0.508 and at a liquid temperature of 80°F (27°C) is computed as follows: From Table 4.4.2.1, L = 0.45, and from Table F.3.3, F = 0.967. Thus,

0.45 0.508 X 0.967 = 0.915 (91%) or 27,300 gal (103 m3)

F.5.2 Alternate Method of Filling Containers. F.5.2.1 Containers equipped with fixed maximum level gauges or with variable liquid level gauges when temperature determinations are not practical can be filled with either gauge provided that the fixed maximum liquid level is installed or the variable gauge is set to indicate the volume equal to the maximum permitted filling limit as provided in 4.4.3.3(a). The level is computed on the basis of the liquid temperature being 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers. F.5.2.2 The percentage of container capacity that can be filled with liquid is computed by use of the formula shown in F.5.1.2, substituting the appropriate values as follows: Vt =

L GXF

where: t = the liquid temperature [assumed to be 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers]. L = the loading limit obtained from Table 4.4.2.1 for: (a) The specific gravity of the LP-Gas to be contained. (b) The method of installation, aboveground or underground, and if aboveground, then: (1) For containers of 1200 gal (4.5 m3) water capacity or less. (2) For containers of more than 1200-gal (4.5-m3) water capacity. G = the specific gravity of the LP-Gas to be contained. F = the correction factor (obtained from Table F.3.3, using G and 40°F (4°C) for aboveground contain ers or 50°F (10°C) for underground containers).

Example: The maximum volume of LP-Gas with a specific gravity of 0.508 that can be in a 1000-gal (3.8-m3) water capacity aboveground container that is filled by use of a fixed maximum liquid level gauge is computed as follows: t = is 40°F (4.4°C) for an aboveground container. L = for 0.508 specific gravity, and an aboveground container of less than 1200-gal (4.5-m3) water capacity, from Table 4.4.2.1, is 42 percent. G = is 0.508. F = for 0.508 specific gravity at 40°F (4.4°C) from Table F.3.3 is 1.033. Thus, V40 =

0.45 0.508 X 1.033 = 0.800 (80%) or 8000 gal (3 m3)

* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

215

appendices

V80 =

(continued)

12


SECTION

12

LP Container Requirements

Table 3.2.2.2 Separation Distances Between Containers, Important Buildings, and Other Properties* minimum distances Water capacity per container gal

m3

<125d

<0.5d

mounded or underground containersa ft

125-250

0.5 - 1.0

251-500

1.0+ - 1.9

501-2000

1.9+ - 7.6

m

10

3

aboveground containersb ft

M

FT

M

a

0e

0e

0

0

b

10

3

0

0

10

3

3

1

25

7.6

3

1

2001-30,000

7.6+ - 114

50

15

30,001-70,000

114+ - 265

75

23

70,001-90,000

265+ - 341

100

30

90,001-120,000

341+ - 454

125

38

50

15

120,001-200,000

454+ - 757

200

61

200,001-1,000,000

757+ - 3785

300

91

>1,000,000

>3785

400

122

Table 3.2.2.2(d) Separation Distance Between Container Pressure Relief Valve and Building Openings

distance Horizontally from relief valve discharge to opening below exchange discharge container or filled type on site ft M Cylinder

Exchange

3.0

0.9

discharge fROm relief valve, vent discharge, and filling connection to exterior source of ignition, openings into direct-vent appliances, mechanical ventilation air intakes FT

M

5.0

1.5

Cylinder

Filled On Site

3.0

0.9

10.0

3.0

ASME

Filled On Site

5.0

1.5

10.0

3.0

(f ) Where underground multicontainer installations are made of individual containers having a water capacity of 125 gal (0.5 m3) or more, such containers shall be installed so as to allow access at their ends or sides to facilitate working with cranes or hoists. (g) In applying the distance between buildings and ASME containers of 125-gal (0.5-m3) or more water capacity, a minimum of 50 percent of this horizontal distance shall also apply to all portions of the building that project more than 5 ft. (1.5 m) from the building wall and that are higher than the relief valve discharge outlet. This horizontal distance shall be measured from a point determined by projecting the outside edge of such overhanging structure vertically downward to grade or other level upon which the container is installed.

216

Gas Equipment Catalog

between containersc

See 3.2.2.2 Exception No. 2. See 3.2.2.2 (g). c See 3.2.2.2 (f ). s See 3.2.2.2 (a). e See 3.2.2.2 (b), (c), and (d).

1/4 of sum of

diameters of adjacent containers

Exception No. 1: Not applicable to installations in which overhanging structure is 50 ft. (15 m) or more above the relief valve discharge outlet. Exception No. 2: Where the distance from a 2001 to 30,000 gal. container to a building are in accordance with 3.11.2 and 3.11.4. 3.2.2.3 Where storage containers having an aggregate

water capacity of more than 4000 gal (15.1 m3) are located in heavily populated or congested areas, the siting provisions of 3.2.2.2 and Table 3.2.2.2 shall be permitted to be modified as indicated by the fire safety analysis described in 3.10.2.2. 3.2.2.4 Aboveground multicontainer installations comprised of containers having an individual water capacity of 12,000 gal (45 m3) or more and installed for use in a single location shall be limited to the number of containers in one group, with each group separated from the next group in accordance with the degree of fire protection provided in Table 3.2.2.4. Exception: Where the provisions of 3.11.3 and 3.11.4 are met the minimum separation distance between groups of ASME containers protected by hose stream only shall be one-half the distances in Table 3.2.2.4. 3.2.2.5 Underground or mounded containers shall be located outside of any buildings. Buildings shall not be constructed over any underground or mounded containers. Sides of adjacent containers shall be separated in accordance with Table 3.2.2.2 but shall not be separated less than 3 ft. (1 m). Where underground or mounded containers are installed parallel with ends in line, the number of containers in one group shall not be limited. Where more than one row is installed, the adjacent ends of the tanks in each row shall be separated by not less than 10 ft. (3 m). * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

victormfg.com


SECTION

12

LP Container Requirements

Important Safety Information for the Dealer and Your Service and Installation Personnel Why is the fill so important? It is important that the first time a new propane tank is filled that it be filled to its maximum allowable liquid level with propane. This will help counteract the possible depletion of the odorant added to propane as a warning device in the event of a gas leak. Why? This puts the maximum amount of gas in the tank, which in turn puts the highest volume of ethyl mercaptan in the tank at a time when the odorant is most likely to be absorbed, absorbed or broken down by oxidation in the tank. If the odor produced by ethyl mercaptan is allowed to fade too much, its effectiveness as a warning device is diminished or may even be eliminated. The propane dealer should advise and warn the customer: • About the presence of the odorant in propane gas and give the customer a scratch-and-sniff pamphlet to allow those using the propane gas to become familiar with the smell of the odorant. • That the odorant can fade or become less intense. Competing odors and a person’s inability to smell can also mask or cover up propane odor. • Gas detectors may provide an extra measure of safety. • They should not rely only upon the smell of propane for detection of propane gas. Failure to properly advise the users of propane about its properties and those of ethyl mercaptan could lead to a severe fire or explosion hazard, resulting in death or bodily injury. Why is putting methanol in a tank so important? Freeze-ups!!!

Warning and notice about the proper installation of propane tanks designed for use underground. When a tank is designed for use in the underground storage of propane gas, a licensed propane dealer or installer must install it. The party installing the tank must inspect the tank and ensure that at the time of installation the external coating applied to the tank by the manufacturer remains continuous and intact. Failure to install the propane tank with an intact and continuous external coating voids all warranties (but not disclaimers) of the manufacturer. It is the responsibility of the purchaser or installer 1) determine whether additional protection should be used and 2) determine mat the additional protection is compatible with the coating applied by the manufacturer. To help ensure long-term protection of the underground tank, cathodic protection; should be used and may be required by governing authorities having jurisdiction over the installation of underground propane tanks at the installation site. This tank is sold subject to and limited by the terms and conditions of sale, including, but not limited to, the manufacturer’s warranty. Periodic inspections of tanks installed underground are recommended and may be required by the jurisdiction where installed. The container and valves of propane tanks to be buried underground should also be carefully checked for leaks immediately prior to installation in the ground. The licensed propane dealer or installer should make sure they follow all applicable federal, state or local regulatory requirements for protective coatings when they install a propane tank underground. The purchaser and installer are responsible for compliance with such federal, state and local regulations.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

appendices

An LP-gas regulator can double for a fairly effective small refrigerator. This is because the high-pressure gas, coming into the regulator, expands as it goes through the orifice. This expansion of gas creates refrigeration. Therefore, if there is moisture in the gas, small droplets may freeze as they are attempting to pass through the cold orifice. If the flow of gas is large enough and there is enough moisture in the fuel, the orifice of the regulator could well be blocked by ice, stopping the flow of gas. Freeze-ups can occur even though outside temperatures are above freezing. How does moisture get in the tank? ASME tanks are hydrostatically tested during fabrication, thereby introducing moisture to the tank. Vacuum pre-purging of tanks should eliminate most of this moisture and air containing moisture from the tank. That is why it is important that air (which will contain moisture) not be allowed into the tank when the vacuum is neutralized when first filling a vacuum pre-purged tank. The easiest way to cure this type of freeze-up is to keep as much moisture as possible from your fuel. Adding genuine absolute anhydrous methanol (99.85 pure) to your tanks when you first fill them is extra insurance to prevent freezeups from any moisture that may still be in the new tank. Methanol will lower the freezing point of water sufficiently to prevent freezing. When mounting the regulator, be sure the regulator outlet is higher than the service valve outlet.

If pigtails are “looped,” be sure the loop is upward, preventing moisture from collecting and freezing at the bottom of the loop. Many times regulators are blamed for freeze-ups when ice frozen in the pigtails is the cause. Use larger pigtails (3/8” OD hogtails have more than three times the cross-sectional area of the standard 1/4” pigtail). Twostage regulation helps prevent freeze-ups.

12 217


LP Container Requirements

SECTION

12

Purging LP-Gas Containers

Up to 2,000 Water Gallon Capacity — ASME & DOT Containers, Including Motor Fuel Containers. Purging and Moisture Removal Methanol Injection Chart All new containers (and in some cases used containers) – Suggested Amounts may contain water, air, or other contaminants, and it is essential that these be removed before filling the container 1 pint of methanol per 100 gallons of container capacity and placing it into service. Water vapor present in the gas 100# I.C.C. or D.0.T. cylinder add 1/8 pint or 2 fluid ounces vapor may cause regulator freeze-up at the inlet orifice and interrupt the gas service. Also, it may have an effect on 100 gallon container add 1 pint the ability of the odorant to meet the present standards, 250 gallon container add 2.5 pints as water can cause oxidation (rusting) on the inside of the container and result in “odorant fade.” Air in the container 500 gallon container add 5 pints will cause abnormally high pressure, with the result that 1,000 gallon container add 10 pints the pressure relief valve may open. Air in the system is also 2,000 gallon container add 20 pints likely to cause pilot flames to go out and result in a service call. Additionally, air in the container carries moisture, which can cause service problems. If a container is suspected of being depressurized or open to the atmosphere for a period of Alternate Purge Method Utilizing a Compressor time, it must be re-purged as if it were a new container. An LP-Gas compressor can be used to evacuate air in a To purge a container, the following steps should be taken: container to about 26” of mercury vacuum (2 PSI absolute pressure) when discharging to atmosphere. Hose suitable 1. Purging of containers should be performed in an for vacuum service would be used and all unused valves approved area (see NFPA #58). must be closed. Protective caps on both liquid fill and vapor 2. Determine if the container pressure is zero. Should equalization valves must be screwed on tightly to prevent air the container contain only air pressure, the air may from entering the container when vacuum is applied. When be vented directly to the atmosphere through the pressure has been reduced to 26” of mercury vacuum LP service valve. gas vapor can be introduced until the container has reached 3. If free water is present in the container, it should atmospheric pressure. Add methanol as suggested and the be drained. container is then ready to be filled with liquid LP-gas. 4. Pressurize the container to approximately 15 PSIG This method effectively removes water vapor after the water with LP-gas vapor. Never purge with liquid LP-gas; is drained and reduces air in the container to about 10 of the to do so will cause the moisture vapor to chill and volume at atmospheric pressure. No LP-gas is released to remain in the container. he atmosphere with this process. Evacuation time with the 5. Fully open the container service valve and vent to a 36 CFM compressor is approximately 15 minutes per 1,000 safe atmosphere. gallons of tank capacity. A CFM comporssor would take 6. Repeat fourth and fifth steps for a total of five purgings. approximately 30 minutes per 1,000 gallons of tank capacity. 7. The usual five purge pressurization methods requires Addendum the venting of about 15-18 gallons of LP-gas A. See NFPA-58 for more information on purging. per 1,000 gallons of container capacity. B. Consult Material Safety Data Sheet (MSDS - Methanol) 8. Add the suggested amount of methanol (see chart for additional information on care and handling of on the next column) and close valve. Methanol must methanol. be used in an approved and safe manner. Refer to the C. Consult NPGA Safety Bulletin on “Static Electricity” methanol MSDS for proper handling and warnings. 9. Repressurize the container with odorized LP-gas vapor to 15 PSIG. 10. The container is now ready to be filled with LP-gas. 11. Once filled, all fittings and tank openings should be checked for leaks using an approved leak detecting solution. 12. The container is now ready to be placed in service.

218

Gas Equipment Catalog

victormfg.com


SECTION

12

LP Container Requirements

Why You Should Use Cathodic Protection When Installing an Underground Propane Tank What is Corrosion? Corrosion of a steel tank is an electrical and chemical deterioration of the metal. It is sometimes called “electrolysis”. It causes pits which lead to holes on one place and not another. What is Cathodic Protection? Cathodic protection is a procedure used to protect an object from corrosion by making it a cathode. To make a tank a cathode, you have to attach an anode to it. Both have to be in an electrolyte such as earth or water. To protect a propane tank, you would attach at least one anode consisting of a bar of magnesium metal packed inside a cloth bag containing conductive earth backfill with a wire that is attached to the magnesium and the tank. Usually, 17 lbs. of magnesium and 28 Ibs. of earth backfill are used. The magnesium is a source of electrons for the iron atoms and it is from where d.c. current originates. As long as enough electrons flow from the magnesium through the wire and the connections on the tank, the tank will not corrode.

appendices

Why You Should Use Cathodic Protection When Installing an Underground Propane Tank First, what makes soil corrosive? Soil contains water and dissolved minerals responsible for damaging underground tanks. If you answer any of the following questions yes, then the tank will be corroded by the soil. Will it ever rain or snow there? Will the property owner plant grass, flowers, shrubs or trees over or near the tank? Will the grass, flowers, shrubs or trees be fertilized? Will ground moisture condense on the outside of the tank? Will water condense out of thin air on the surface of a cold container? Will the tank be near a sidewalk or down gradient from a driveway? Will the property owner ever throw salt or calcium chloride on the pavement to melt snow and ice? Will the tank ever be located near or downhill from livestock where salt and urea from animal waste will leach into the earth? Does the irrigation water contain salt or alkali salts? If a tank is set in a hole blasted from solid rock, does the rock contain pyrites, graphite or acidic rock that will be fractured and exposed to the oxidizing effect of air and water? If the tank is backfilled with sand or gravel from a sand or gravel company, will the sand contain minerals mined from river deposits not representative of the site in which the tank is to be buried? Will the tank be downhill from a septic tank leach field? Will the soil contain gypsum? Will the tank be set in shale or clay? Will groundwater be present? Will the tank be set on undisturbed earth and backfilled with loose backfill?

hold up under constant contact with mineralized moisture in the earth. Therefore, specialized coatings are needed to withstand the corrosive environment underground and provide a barrier between the steel surface and air, water and even electricity without deteriorating over time. The first line of defense against corrosion on an underground tank is good coating. Paint and coating companies make a variety of coatings for a vast array of applications. It is important to apply those that will hold up over time to constant attack by water, oxygen, carbon dioxide, mild acids, mechanical abrasion from rocks, earth movements, roots, bacteria and other biological organisms as they feed on organic compounds in them. They must be applied correctly or they will not adhere to the steel surface. Quality Steel applies a tough chemical and water resistant coating at the factory — a hard, baked on polyurethane finish. This factory applied coating is designed to be the final coating for the tank prior to its burial in the ground, provided the tank has an intact and continuous external coating at the time of burial. It is the installer’s responsibility to thoroughly inspect the tank to determine whether the factory applied protective coating is intact and continuous. If the coating is not found to be intact and continuous, then additional protection that is compatible with the manufacturer’s coating must be applied in a way to obtain this important result prior to burial. Coatings alone may not protect a buried tank against corrosion. After inspection and touchup the tanks can still get scratched, scraped and gouged during handling, setting, backfilling and settling. As a result the coating can have small imperfections here and there. Corrosion pitting rates are greater at these flaws, scratches and gaps in the coating than they are on completely bare tanks. Therefore, cathodic protection with anodes is needed to protect the steel wherever it is exposed. So, what can you do to provide cathodic protection for the underground propane tank? Anodes of magnesium are used to make the propane tank a cathode, thus improving its protection against possible corrosion. Magnesium anodes come in all shapes and sizes. The magnesium in a packaged anode can weigh from 1 to 50 Ibs. The most commonly used anode in the United States is a 17 Ib. anode. With 28 Ibs. of powdered backfill packed around the magnesium, a packaged 17 lbs.anode weighs about 45 Ibs.

Second, let’s consider coatings, the traditional way of preparing underground propane tanks for installation. All steel objects are painted to keep them

from rusting. The paint is a waterproof barrier between the steel surface and moisture in the air. Similarly, underground tanks need a waterproof coating to protect them from corrosive groundwater. Ordinary paint coatings do not

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

12 219


SECTION

12

LP Container Requirements Why You Should Use Cathodic Protection When Installing an Underground Propane Tank (continued) Tests on underground propane tanks have shown that smaller anodes can be effective at controlling corrosion on a well coated tank. Small anodes are used when the surface area or object to be protected is small. They cost less but cost the same as a large anode to install. However, it is important to remember that the life of a small anode is shorter than for a larger one. One of the more common questions asked is, “How long will an anode last?” Design engineers prefer to use larger anodes (and in greater numbers) because they last longer. The conditions and environment in which tanks and anodes are buried are so varied (as well as change with time) so that there is no definitive answer. Finally, however, when an anode is 85 consumed, it becomes too small to be effective. Because soil conditions change with time, one can hope for the best but plan for the worst. How do you install the anode? This is a very important question, for if the anode is not properly installed, it will not work. Schmoldt recommends the following: Install one 17 Ib. magnesium anode on a 500 gal. tank and two on a 1,000 gal. tank. The reason for the latter is to ensure that enough cathodic protection current is available for many years. Bury the anode at the end of the excavation where the earth is the wettest and the most conductive to the anode current. If water is available, pour 5 gal. on the anode to “jump start” the flow of current. Otherwise, the dry backfill will have to absorb moisture from the soil before current will flow. Roll out the anode wire to either the flat plate fitting on top of the tank or to the lifting ear. Wrap the wire around the fitting or ear so that the connection can not be pulled off should someone trip on the wire. Leave slack in the wire so that it is not pulled apart when the excavation is backfilled.

The wire can be attached to the tank by a thermite weld or with a nut and bolt. Whether you use a thermite weld or nut and bolt, remove 1” insulation on the copper wire and file off any paint or coating at the connection so that the metal wire is making contact to the tank for the weld or connection. If you use a thermite weld, the weld will not ignite the propane in the tank, but it could ignite propane in sufficient concentration in the excavation around the tank. Propane is heavier than air and will collect at your feet. If you smell propane, do not make the connection with the weld. So, how do you know a tank is protected? It doesn’t take long to check, and a check should be made at least annually. If the voltage of steel is -0.85 volts or greater, it is protected. It takes a voltmeter and a copper sulfate electrode to take the reading. It can be taken by your service person with a basic understanding of cathodic protection. If the reading is >-0.85 volts, you can assume that the tank is protected at the location where the reading was taken on the date it was taken. If the reading is <-0.85 volts, the anode installed on the tank either has been consumed, or the tank is connected to the house utilities without dielectric union, or the wire has been disconnected. Occasionally, there is a problem with the testing equipment or contact to the tank. The voltmeter’s contact with the tank can be made on any metal connected to the tank, including the gauging device, the regulator, the pressure relief valve or other fittings. The dome is not a good contact point. It is recommended that you take at least four readings around the tank.

Victor/F.w. Webb stocks burnham boilers.

220

Gas Equipment Catalog

victormfg.com


SECTION

12

LP Container Requirements

Cylinders Figure I.1 (a)*

Windows air conditioner (source of ignition) tIntake to direc vent appliance 5 ft. (min) (Note 1)

Central AC Compressor (source of ignition)

5 ft. (min) (Note 1)

10 ft. (min) (Note 2)

Cylinders not filled on site from bulk truck

3 ft. (min) (Note 3)

3 ft. (min) (Note 3) Crawl space opening, windows, or exhaust fan

Cylinders not filled on site

For SI units, 1 ft. = 0.3048 m Note 1: 5 ft. minimum front relief valve in any direction away from any exterior sources of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 6.3.7(2). Note 2: If the cylinder is filled on site from a bulk truck, the filling connection and vent valve must be at least 10 ft. from any exterior source of ignition, openings into direct-vent appliances, ore mechanical ventilation air intakes. Refer to 6.3.10. Note 3: Refer to 6.3.7(1).

Aboveground ASME Containers Figure I.1 (b)*

Central AC Compressor (source of ignition) 10 ft. (min) (Note 1)

Intake to directvent appliance

125 Undel rw.c. ga

10 ft. (min) (Note 1) 5 ft. (min) (Note 2) 25 ft. (min) (Note 3)

Note 1: Regardless of its size, any ASME container filled on site must be located so that the filling connection and fixed maximum liquid level gauge are at least 10 ft. from any external source of ignition (e.g., open flame, window AC, compressor), intake to direct-vented gas appliance, or intake to a mechanical ventilation system. Refer to 6.3.10. Note 2: Refer to 6.3.9.

501

-20

00

gal

10 ft. (min) (Note 1)

125-

10 ft. (min) (Note 1) 500

Window air conditioner (source of ignition)

gal w .c.

10 ft. (min) (Note 1)

w.c .

25 ft. (min) (Note 3)

Note 3: This distance can be reduced to no less than 10 ft. for a single container of 1,200 gal. (4.5 m3) water capacity or less, provided such container is at least 25 ft. from any other LP-Gas container of more than 125 gal. (0.5 m3) water capacity. Refer to 6.3.3. * Figures are for illustrative purposes only; code shall govern.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

221

appendices

Under 125 gal. w.c.

12


SECTION

12

LP Container Requirements Underground ASME Containers Figure I.1 (c)*

Window air conditioner ition (source of ign Intake to directvent appliance

10 ft. (min) (Note 1) 10 ft. (min) (Note 1) 10 ft. (min) Central AC Compressor (Note 1) (source of ignition) 2000 g al w or less .c.

10 ft. (min) (Note 2)

Crawl space opening, window, or exhaust fan

10 ft. (min) (Note 2)

For SI units, 1 ft. = 0.3048 m Note 1: The relief valve, filling connection, and fixed maximum liquid level gauge vent connection at the container must be at least 10 ft. from any exterior source of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 6.3.10. Note 2: No part of an underground container can be less than 10 ft. from an important building or line of adjoining property that can be built upon. Refer to 6.3.4.2.

Victor/F.w. Webb stocks both lyco mechanical fittings and continential stab fittings for underground pe gas pipe.

* Figures are for illustrative purposes only; code shall govern.

222

Gas Equipment Catalog

victormfg.com


SECTION

12

Orifice Sizing and Properties of LP Gases

Table F.2 LP-Gases* (Btu per hour at sea level)

Propane Butane Btu per cubic foot = 2488 3280 Specific gravity = 1.50 2.01 Pressure at orifice, inches water column = 11 11 Orifice coefficient = 0.9 0.9 For altitudes above 2000 ft. first select the equivalent orifice size at sea level from Table F.4. Table F.2 LP-Gases (Btu per hour at sea level)

Propane 519 656 812 981 1169 1480 1708 2080 2629 3249 3581 4119 4678 5081 5495 6375 6934 7813 8320 8848 9955 10535 11125 11735 12367 13008 13660 14333 15026 17572 21939 24630 28769 32805

rifice O or Drill Size 51.000 50.000 49.000 48.000 47.000 46.000 45.000 44.000 43.000 42.000 41.000 40.000 39.000 38.000 37.000 36.000 35.000 34.000 33.000 32.000 31.000 30.000 29.000 28.000 27.000 26.000 25.000 24.000 23.000 22.000 21.000 20.000 19.000 18.000

Propane 36531 39842 43361 46983 50088 53296 54641 60229 64369 71095 74924 78029 80513 83721 87860 92207 98312 100175 103797 109385 117043 134119 150366 160301 168580 175617 181619 187828 192796 200350 205525 210699 223945 233466

Specific Gravity 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90

Specific Multiplier 1.155 1.095 1.045 1.000 0.961 0.926 0.894 0.866 0.840 0.817

Gravity 0.95 1.00 1.05 1.10 1.15 1.20 1.25 1.30 1.35 1.40

Multiplier 0.795 0.775 0.756 0.739 0.722 0.707 0.693 0.679 0.667 0.655

* This section is an excerpt from the NFPA 54 National Fuel Gas Code ­— 1999 Edition

Approximate Properties LP-Gases*

Commercial Propane Vapor Pressure In PSI (Absolute Pressure At) 70°F 100°F 105°F 130°F Specific Gravity Of Liquid At 60°F Initial Boiling Point At 14.7 psia, °F Weight Per Gallon Of Liquid At 60°F, lb. Specific Heat Of Liquid, btu/lb. At 60°F Cubic Feet Of Vapor Per Gallon At 60°F Cubic Feet Of Vapor Per Pound At 60°F Specific Gravity of Vapor (Air = 1) At 60°F Ignition Temperature In Air, °F Maximum Flame Temperature In Air, °F Limits Of Flammability In Air Percent Of Vapor In Air–Gas Mixture: Lower Upper

145 218 233 315 0.504 –44 4.20 .630 36.38 8.66 1.50 920 – 1,120 3,595

2.15 9.60

appendices

rifice O or Drill Size 00.008 00.009 00.010 00.011 00.012 80.000 79.000 78.000 77.000 76.000 75.000 74.000 73.000 72.000 71.000 70.000 69.000 68.000 67.000 66.000 65.000 64.000 63.000 62.000 61.000 60.000 59.000 58.000 57.000 56.000 55.000 54.000 53.000 52.000

Table F.3 Multipliers for Utility Gases of Another Specific Gravity*

atent Heat Of Vaporization At Boiling Point L btu Per Pound 184 btu Per Gallon 773 Total Heating Values After Vaporization btu Per Cubic Foot btu Per Pound btu Per Gallon

2,488 21,548 91,502

* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

223

12


SECTION

12

Orifice Sizing and Properties of LP Gases

Table F.1 Utility Gases*(or Natural Gas Specific Gravity .60) (cubic feet per hour at sea level)

Orifice Pressure at Orifice 3/4 Inches Water Column or Drill Size 3.5 4 7 80 0.52 0.55 0.73 79 0.59 0.64 0.84 78 0.76 0.78 1.04 77 0.95 0.99 1.31 76 1.13 1.21 1.61

Orifice Pressure at Orifice 3/4 Inches Water Column or Drill Size 3.5 4 7 35 34.95 36.86 48.78 34 35.05 37.50 49.75 33 36.08 38.79 51.46 32 38.30 40.94 54.26 31 40.85 43.83 58.01

75 74 73 72 71

1.25 1.44 1.63 1.77 1.97

1.34 1.55 1.76 1.90 2.06

1.79 2.05 2.32 2.52 2.73

30 29 28 27 26

46.87 52.33 55.92 58.83 61.27

50.39 56.19 59.50 63.17 65.86

66.72 74.45 79.50 83.59 87.24

70 69 68 67 66

2.22 2.43 2.72 2.91 3.09

2.39 2.61 2.93 3.12 3.32

3.16 3.47 3.88 4.13 4.39

25 24 23 22 21

63.58 65.67 67.07 70.08 71.83

68.22 70.58 72.20 75.21 77.14

90.36 93.47 94.55 99.60 102.29

65 64 63 62 61

3.39 3.68 3.92 4.08 4.34

3.72 4.14 4.19 4.39 4.66

4.84 5.23 5.55 5.81 6.15

20 19 18 17 16

73.68 77.98 81.57 84.82 88.77

79.08 83.69 87.56 91.10 95.40

104.75 110.67 116.03 120.33 126.78

60 59 58 57 56

4.55 4.76 5.03 5.23 6.13

4.89 5.11 5.39 5.63 6.58

6.47 6.78 7.13 7.44 8.73

15 14 13 12 11

92.02 94.40 97.11 101.41 103.62

98.84 100.78 104.32 108.52 111.31

131.07 133.22 138.60 143.97 147.20

55 54 53 52 51

7.68 8.59 10.04 11.46 12.77

8.22 9.23 10.80 12.31 13.69

10.85 12.25 14.29 16.34 18.16

10 9 8 7 6

106.16 109.07 112.20 114.40 117.88

114.21 117.11 120.65 123.01 126.78

151.50 154.71 160.08 163.31 167.51

50 49 48 47 46

13.92 15.20 16.36 17.52 18.57

14.94 16.28 17.62 18.80 19.98

19.77 21.60 23.31 24.93 26.43

5 4 3 2 1

119.97 123.93 128.79 138.76 147.26

128.93 133.22 137.52 148.61 158.25

170.82 176.18 182.64 197.66 209.48

45 44 43 42 41

19.15 21.01 22.39 24.95 25.98

20.52 22.57 24.18 26.50 28.15

27.18 29.87 32.02 35.24 37.17

40 39 38 37 36

27.03 28.20 29.25 30.63 32.14

29.23 30.20 31.38 32.99 34.59

38.79 39.97 41.58 43.62 45.77

For SI units, 1 Btu/hr = 0.293 W; 1 ft3 = 0.028 m3; 1 ft = 0.305 m; 1 in. water column = 249 pa. Notes: 1. Specific Gravity = 0.60; orifice coefficient = 0.90. 2. For utility gases of another specific gravity, select multiplier from Table F.3. For altitudes above 2000 ft, first select the equivalent orifice size at sea level from Table F.4.

* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

224

Gas Equipment Catalog

victormfg.com


SECTION

12 Liquid Volume Tables and Temperature Correction Factors

Appendix F Liquid Volume Tables, Computations and Graphs This appendix is not a part of the requirements of this NFPA document but is included for informational purposes only.

F.1 Scope.

F.1.1 Application. This appendix explains the basis

for Table 4.4.2.1, includes the LP-Gas liquid volume temperature correction table, Table F.3.3, and describes its use. It also explains the methods of making liquid volume computations to determine the maximum permissible LP-Gas content of containers in accordance with Tables 4.4.2.2(a), (b), and (c).

F.2 Basis for Determination of LP-Gas Container Capacity. The basis for determination of the maximum permitted filling limits shown in Table 4.4.2.1 is the maximum safe quantity that will assure that the container will not become liquid full when the liquid is at the highest anticipated temperature. F.2.1 For portable containers built to DOT specifications and other aboveground containers with water capacities of 1200 gal (4.5 m3) or less, this temperature is assumed to be 130°F (54°C). F.2.2 For other aboveground uninsulated containers with water capacities in excess of 1200 gal (4.5 m3), including those built to DOT portable or cargo tank specifications, this temperature is assumed to be 115°F (46°C). F.2.3 For all containers installed under ground, this temperature is assumed to be 105°F (41°C).

(2) If the container is not equipped with a well, but is essentially empty of liquid prior to loading, the temperature of the liquid in the container from which liquid is being withdrawn can be used. Otherwise, a thermometer can be inserted in a thermometer well or other temperature-sensing device installed in the loading line at a point close to the container being loaded. Read temperatures at intervals during trans fer and averaging. [See F.3.2(c).] (3) A suitable liquid should be used in thermometer wells to obtain an efficient heat transfer from the LP Gas liquid in the container to the thermometer bulb. The liquid used should be noncorrosive and should not freeze at the tem-peratures to which it will be subjected. Water should not be used. F.3.3 The volume observed or measured is corrected to 60....F (16....C) by use of Table F.3.3. The column headings, across the top of the tabulation, list the range of specific gravities for the LP-Gases. Specific gravities are shown from 0.500 to 0.590 by 0.010 increments, except that special columns are inserted for chemically pure propane, isobutane, and normal butane. To obtain a correction factor, follow down the column for the specific gravity of the particular LP-Gas to the factor corresponding with the liquid temperature. Interpolation between the specific gravities and temperatures shown can be used if necessary.

appendices

F.3 Liquid Volume Correction Table. Correction of observed volume to standard temperature condition (60°F and equilibrium pressure). F.3.1 The volume of a given quantity of LP-Gas liquid in a container is directly related to its temperature, expanding as temperature increases and contracting as temperature decreases. Standard conditions, often used for weights and measures purposes and, in some cases, to comply with safety regulations, specify correction of the observed volume to what it would be at 60°F (16°C). F.3.2 To correct the observed volume to 60°F (16°C), the specific gravity of LP-Gas at 60°F (16°C) in relation to water at 60°F (16°C) (usually referred to as “60°/60°F”) and its average temperature must be known. The specific gravity normally appears on the shipping papers. The average liquid temperature can be obtained as follows: (1) Insert a thermometer in a thermometer well in the container into which the liquid has been transferred, and read the temperature after the completion of the transfer. [see F.3.2(c) for proper use of a thermometer].

* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

225

12


SECTION

Liquid Volume Tables and Temperature Correction Factors 12 Liquid Volume Correction Factors* Specific Gravities at 60°F/60°F Observed Temp., Degrees Propane Fahrenheit 0.5079 –50 1.155 –45 1.148 –40 1.142 –35 1.135 –30 1.129 –25 1.122 –20 1.115 –15 1.109 –10 1.102 –5 1.094 0 1.088 2 1.086 4 1.083 6 1.080 8 1.078 10 1.075 12 1.072 14 1.070

Observed Temp., Degrees Propane Fahrenheit 0.5079 16 1.067 18 1.065 20 1.062 22 1.059 24 1.056 26 1.053 28 1.050 30 1.047 32 1.044 34 1.041 36 1.038 38 1.035 40 1.032 42 1.029 44 1.026 42 1.029 44 1.026 46 1.022

Observed Temp., Degrees Propane Fahrenheit 0.5079 48 1.019 50 1.016 52 1.013 54 1.010 56 1.007 58 1.003 60 1.000 62 0.997 64 0.993 66 0.990 68 0.986 70 0.983 72 0.980 74 0.976 76 0.973 78 0.970 80 0.967 82 0.963

Observed Temp., Degrees Propane Fahrenheit 0.5079 84 0.959 86 0.956 88 0.952 90 0.949 92 0.945 94 0.941 96 0.938 98 0.934 100 0.930 105 0.920 110 0.911 115 0.902 120 0.892 125 0.881 130 0.871 135 0.861 140 0.850

* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

226

Gas Equipment Catalog

victormfg.com


SECTION

12

Vaporizer and Electrical Requirements

3.6.3 Installation of Direct-Fired Vaporizers

3.6.3.1 Direct-fired vaporizers shall comply with 2.5.5.2

and shall be installed as follows.

3.6.3.2 Where a direct-fired vaporizer is installed in

a separate structure, the separate structure shall be constructed in accordance with Chapter 7. 3.6.3.3 The housing for direct-fired vaporizers shall not have any drains to a sewer or a sump pit that is shared with any other structure or to a sewer. Pressure relief valve discharges on direct-fired vaporizers shall be piped to a point outside the structure or building. 3.6.3.4 Direct-fired vaporizers shall be connected to the liquid space or to the liquid or vapor space of the container. A manually operated shutoff valve shall be installed in each connection of the container supplying the vaporizer. 3.6.3.5 Direct-fired vaporizers of any capacity shall be located in accordance with Table 3.6.3.5. Table 3.6.3.5 Minimum Separation Distances Between Direct-Fired Vaporizers and Exposures

3.7.2 Electrical Equipment 3.7.2.1 Electrical equipment and wiring shall be of a type

specified by, and installed in accordance with, NFPA 70, National Electrical Code®, for ordinary locations. Exception: Fixed electrical equipment in classified areas shall comply with 3.7.2.2. 3.7.2.2* Fixed electrical equipment and wiring installed within classified areas specified in Table 3.7.2.2 shall comply with Table 3.7.2.2 and shall be installed in accordance with NFPA 70, National Electrical Code. The provision shall apply to vehicle fuel operations. (See Figure 3.7.2.2.) Exception: This provision shall not apply to fixed electrical equipment at residential or commercial installations of LP-Gas systems or to systems covered by Section 3.8.

FIGURE 3.7.2.2 Extent of electrically classified area. (See Table 3.7.2.2.) 3.7.2.3 Fired vaporizers, calorimeters with open flames, and other areas where open flames are present either intermittently or constantly shall not be considered electrically classified areas.

Minimum Distance Required Exposure ft m Container 10 3.0 Container Shutoff Valves 15 4.6 Point Of Transfer 15 4.6 Nearest Important Buildings Or Group Of 25 7.6 Buildings Or Line Of Adjoining Property That Can Be Built Nearest Chapter 7 Building Or Room 10 3.0 Housing Gas–Air Mixer Cabinet Housing Gas–Air Mixer Outdoors 0 0 Note: Do not apply distances to the building in which a direct-fired vaporizer is installed.

appendices

3.6.6. Installation of Waterbath Vaporizers. Waterbath vaporizers shall comply with 2.5.5.3 and shall be installed as follows: 3.6.6.1 If a waterbath vaporizer is electrically heated and all electrical equipment is suitable for Class 1, Group D locations, the unit shall be treated as indirect-fired and shall be installed in accordance with 3.6.2. 3.6.6.2 All other waterbath vaporizers shall be treated as direct-fired vaporizers and shall be installed in accordance with 3.6.3. 3.6.7 Installation of Electric Vaporizers. Electric vaporizers, whether direct immersion or indirect immersion, shall be treated as indirect-fired and shall be installed in accordance with 3.6.2.

12

* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

227


Suggested Method of Leak Checking

SECTION

12

D. Suggested Method for Checking for Leakage* This appendix is not a part of the requirements of this code but is included for informational purposes only. D.1 Use of Lights. Artificial illumination used in connection with a search for gas leakage should be restricted to battery-operated flashlights (preferably of the safety type) or approved safety lamps. In searching for leaks, electric switches should not be operated. If electric lights are already turned on, they should not be turned off. D.2 Testing for Leakage Using the Gas Meter. Immediately prior to the test, it should be determined that the meter is in operating condition and has not been bypassed. Checking for leakage can be done by carefully watching the test dial of the meter to determine whether gas is passing through the meter. To assist in observing any movement of the test hand, wet a small piece of paper and paste its edge directly over the centerline of the hand as soon as the gas is turned on. This observation should be made with the test hand on the upstroke. Table D.2 can be used for determining the length of observation time. Table D.2 Test Observation Times for Various Meter Dials Dial Styles (ft3) 1/4 1/2 1 2 5 10

Test Time (minutes) 5 5 7 10 20 30

For SI units, 1 ft 3 = 0.028 m3.

In case careful observation of the test hand for a sufficient length of time reveals no movement, the piping should be purged and a small gas burner turned on and lighted, and the hand of the test dial again observed. If the dial hand moves (as it should), it will show that the meter is operating properly. If the test hand does not move or register flow of gas through the meter to the small burner, the meter is defective and the gas should be shut off and the serving gas supplier notified.

(1) (2)

appliance regulators, and control valves in the system. Accordingly, each individual equipment shutoff valve should be supplying pressure to its appliance for the leak check. This check will prove the integrity of the 100 percent pilot shutoff of each gas valve so equipped, so the manual gas cock of each gas valve incorporating a 100 percent pilot shutoff should be in the on position. Pilots not incorporating a 100 percent pilot shutoff valve and all manual gas valves not incorporating safety shutoff systems are to be placed in the off position prior to leak checking, by using one of the following methods: By inserting a pressure gauge between the container gas shutoff valve and the first regulator in the system, admitting full container pressure to the system and then closing the container shutoff valve. Enough gas should then be released from the system to lower the pressure gauge reading by 10 psi (69 kPa). The system should then be allowed to stand for 3 minutes without showing an increase or a decrease in the pressure gauge reading. For systems serving appliances that receive gas at pressures of 1/2 psi (3.5 kPa) or less, by inserting a water manometer or pressure gauge into the system downstream of the final system regulator, pressurizing the system with either fuel gas or air to a test pressure of 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column, and observing the device for a pressure change. If fuel gas is used as a pressure source, it is necessary to pressurize the system to full operating pressure, close the container service valve, and then release enough gas from the system through a range burner valve or other suitable means to drop the system pressure to 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column. This ensures that all regulators in the system are unlocked and that a leak anywhere in the system is communicated to the gauging device. The gauging device should indicate no loss or gain of pressure for a period of 3 minutes.

D.3 Testing for Leakage Not Using a Meter.

This test can be done by one of the following methods: (a) For Any Gas System. To an appropriate checkpoint, attach a manometer or pressure gauge between the inlet to the piping system and the first regulator in the piping system, and momentarily turn on the gas supply and observe the gauging device for pressure drop with the gas supply shut off. No discernible drop in pressure should occur during a period of 3 minutes. (b) For Gas Systems Using Undiluted Liquefied Petroleum Gas. System Preparation for Propane. A leak check performed on an LP-Gas system being placed back in service should include all regulators, including

228

Gas Equipment Catalog

victormfg.com


SECTION

12

Suggested Method of Leak Checking

D. Suggested Method for Checking for Leakage 3.2.15.3 Metallic pipe joints shall be permitted to be threaded, flanged, welded, or brazed using pipe and fittings that comply with 2.4.2 and 2.4.4 as follows. (a) Metallic threaded and welded pipe joints shall be in accordance with Table 3.2.15.3(a).

Table 3.2.15.3(a) Types of Metallic Pipe Joints in LP-Gas Service Service Schedule 40 Liquid Welded Vapor, £125 psig Threaded or (£0.9 MPag) Welded Vapor, >125 psig Welded (>0.9 MPag)

Schedule 80 Threaded or Welded Threaded or Welded Threaded or Welded

(b) Fittings and flanges shall be designed for a working pressure equal to or greater than the required working pressure of the service for which they are used. (c) Brazed joints shall be made with a brazing material having a melting point exceeding 1000°F (538°C). (d) Gaskets used to retain LP-Gas in flanged connections in piping shall be resistant to the action of LP-Gas. They shall be made of metal or material confined in metal having a melting point over 1500°F (816°C) or shall be protected against fire exposure. When a flange is opened, the gasket shall be replaced. Exception No. 1: Aluminum O-rings and spiral wound metal gaskets shall be permitted. Exception No. 2: Nonmetallic gaskets used in insulating fittings shall be permitted.

3.2.15.4 Metallic tubing joints shall be flared or brazed using tubing and fittings in accordance with 2.4.3 and 2.4.4. 3.2.15.5 Piping in systems shall be run as directly as is practical from one point to another, with as few fittings as practical.

Where condensation of vapor can occur, piping shall be sloped back to the container or means shall be provided for revaporizing the condensate.

(continued)

3.2.15.8 Buried metallic pipe and tubing shall be installed underground with a minimum 18 in. (460 mm) of cover. The cover shall be permitted to be reduced to 12 in. (300 mm) if external damage to the pipe or tubing is not likely to result. If a minimum 12 in. (300 mm) of cover cannot be maintained, the piping shall be installed in conduit or shall be bridged (shielded). Where underground piping is beneath driveways, roads, or streets, possible damage by vehicles shall be taken into account. 3.2.15.9 Underground metallic piping shall be protected against corrosion as warranted by soil conditions (see 3.2.24). 3.2.15.10 LP-Gas piping shall not be used as a grounding electrode.

3.2.16 Polyethylene Pipe, Tubing, and Fittings. 3.2.16.1 Polyethylene pipe, tubing and fittings shall be installed outdoors underground only. 3.2.16.2 Polyethylene pipe and tubing shall be buried as follows: (1) With a minimum 18 in. (460 mm) of cover (2) With a minimum of 12 in. (300 mm) of cover if external damage to the pipe or tubing is not likely to result (3) If a minimum 12 in. (300 mm) of cover cannot be provided, with piping installed in conduit or bridged (shielded). 3.2.16.3 Assembled anodeless risers shall be used to terminate underground polyethylene piping systems above ground. The horizontal portion of risers shall be buried at least 12 in. (300mm) below grade and the casing material used for the risers shall be protected against corrosion in accordance with 3.2.24. 3.2.16.4 Either the aboveground portion of the riser casing shall be provided with a plastic sleeve inside the riser casing or the pipe or tubing shall be centered in the riser casing. 3.2.16.5 Factory-assembled risers shall be sealed and leak tested by the manufacturer.

appendices

3.2.15.6 Piping systems including interconnecting of permanently installed containers shall compensate for expansion, contraction, jarring and vibration, and for settling. Using flexible connectors complying with 2.4.6 shall be permitted. The use of nonmetallic pipe, tubing, or hose for permanently interconnecting such containers shall be prohibited. 3.2.15.7 Aboveground piping shall be supported and

protected against physical damage by vehicles. The portion of aboveground piping in contact with a support or a corrosion-causing substance shall be protected against corrosion.

12 TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

229


Suggested Method of Leak Checking D. Suggested Method for Checking for Leakage*

SECTION

12

(continued)

3.2.16.6 Field-assembled risers shall be supplied only in kit form with all necessary hardware for installation. Field-assembled risers shall comply with the following: (1) Be design certified. (2) Be sealed and pressure tested by the installer. (3) Be assembled and installed in accordance with the riser manufacturer’s instructions. 3.2.16.7 The casing of the riser shall be constructed of one of the following materials: (1) ASTM A 53, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless, Schedule 40 steel pipe. (2) ASTM A 513, Standard Specification for Elec tric-Resistance-Welded Carbon and Alloy Steel Mechanical Tubing, mechanical steel tubing with a minimum wall thickness of 0.073in. (1.9 mm). (3) A flexible metal tubing with a minimum crush strength of 1000 lb (453.6 kg) and a tensile strength of 300 lb (136 kg) including the tran sition connection as tested by the manufacturer. 3.2.16.8* Polyethylene piping shall be installed so as to minimize thrust forces caused by contraction or expansion of the piping or by anticipated external or internal loading. The pipeline shall be designed and installed so that each joint will sustain these forces. 3.2.16.9 An electrically continuous corrosion-resistant tracer wire (minimum AWG 14) or tape shall be buried with the polyethylene pipe to facilitate locating. One end shall be brought aboveground at a building wall or riser. The wire or tape shall not be in direct contact with the polyethylene pipe. 3.2.16.10 Polyethylene piping that is installed in a vault or any other belowground enclosure shall be completely encased in gastight metal pipe and fittings that are protected from corrosion.

* This section is an excerpt from the NFPA 54 National Fuel Gas Code — 1999 Edition

230

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Table N-1 Low Pressure (Standard)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 6-7 inches W.C.; Pressure Drop: 0.5 inch W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

5 63 134 288 546 1109 1790 4142

10 44 95 206 383 789 1261 2934

15 35 77 169 310 646 1027 2398

20 31 67 147 269 561 888 2078

25 27 60 132 240 503 793 1860

30 25 55 121 218 460 723 1698

40 21 47 105 188 399 625 1472

50 19 42 94 168 358 559 1317

60 17 38 86 153 327 509 1203

70 16 36 80 141 303 471 1114

80 15 33 75 132 284 440 1042

90 14 32 71 125 268 415 983

100 13 30 67 118 254 393 933

150 10 23 55 94 208 320 762

200 9 21 48 82 181 277 661

250 8 19 43 74 162 247 591

300 7 17 39 67 148 226 540

Table N-2A Low Pressure (Canada & USA 1 inch drop)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 6-7 inches W.C.; Pressure Drop: 1 inch W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

5 82 182 403 734 1558 2541 5848

10 58 131 288 518 1109 1790 4142

15 48 108 237 423 908 1458 3386

20 42 94 206 366 789 1261 2934

25 37 85 185 327 707 1126 2626

30 34 78 169 299 646 1027 2398

40 30 68 147 259 561 888 2078

50 27 61 132 231 503 793 1860

60 24 56 121 211 460 723 1698

70 23 52 112 195 426 669 1573

80 21 48 105 183 399 625 1472

90 20 46 99 172 377 589 1388

100 19 44 94 163 358 559 1317

150 15 36 77 133 293 455 1076

200 13 31 67 115 254 393 933

250 12 28 60 103 228 351 835

300 11 26 55 94 208 320 762

Table N-2B Low Pressure (Canada & USA 2 inch drop)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 7-8 inches W.C.; Pressure Drop: 2 inches W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) EHD 15 19 25 31 37 46 62

5 115 254 564 1038 2191 3607 8257

10 82 182 403 734 1558 2541 5848

15 67 150 331 599 1277 2070 4780

20 58 131 288 518 1109 1790 4142

25 52 118 258 463 994 1599 3707

30 48 108 237 423 908 1458 3386

40 42 94 206 366 789 1261 2934

50 37 85 185 327 707 1126 2626

60 34 78 169 299 646 1027 2398

70 32 72 157 276 599 950 2221

80 30 68 147 259 561 888 2078

90 28 64 139 244 529 837 1960

100 27 61 132 231 503 793 1860

150 22 50 108 189 412 646 1520

200 19 44 94 163 358 559 1317

250 17 39 84 146 320 499 1179

300 15 36 77 133 293 455 1076

* Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length of tubing and n is the number of additonal fittings and/or bends. EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity; This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

231

appendices

Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

12


SECTION

12

Gas Line Sizing Table N-3 Regulator Outlet (8 inches W.C.)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 8 inches W.C.; Pressure Drop: 3 inches W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 5 15 160 19 327 25 687 31 1365 37 2673 46 4428 62 10103

10 112 231 491 958 1902 3119 7156

15 90 189 403 778 1558 2541 5848

20 78 164 351 672 1353 2197 5069

25 69 147 315 599 1213 1963 4536

30 63 134 288 546 1109 1790 4142

40 54 116 250 471 963 1548 3590

50 48 104 225 421 863 1383 3213

60 44 95 206 383 789 1261 2934

70 41 88 191 355 731 1166 2717

80 38 82 179 331 685 1090 2543

90 36 77 169 311 646 1027 2398

100 34 73 160 295 614 974 2276

150 27 60 132 240 503 793 1860

200 23 52 115 207 436 686 1612

250 21 46 103 184 391 613 1442

300 19 42 94 168 358 559 1317

Table N-3A 3P (11 inches W.C.)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas Gas Pressure: 11 inches W.C.; Pressure Drop: 5 inches W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 5 15 207 19 419 25 878 31 1766 37 3436 46 5732 62 13026

10 144 297 627 1237 2444 4038 9227

15 116 242 515 1005 2003 3290 7541

20 100 210 448 867 1739 2844 6535

25 89 188 402 773 1558 2541 5858

30 81 172 368 704 1425 2317 5341

40 70 149 320 607 1237 2004 4629

50 62 133 287 542 1109 1790 4142

60 56 122 263 493 1014 1632 3783

70 52 113 244 456 940 1510 3504

80 48 105 228 425 880 1411 3279

90 45 99 216 400 831 1330 3092

100 43 94 205 379 789 1261 2934

150 35 77 168 308 646 1027 2398

200 30 67 146 266 561 888 2078

250 26 60 131 237 503 793 1860

300 24 54 120 216 460 723 1698

Table N-4 Medium Pressure*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: .5 psi (12-14 inches W.C.); Pressure Drop: 6 inch W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 5 10 15 229 160 19 461 327 25 962 687 31 1946 1365 37 3757 2673 46 6286 4428 62 14263 10103

15 130 267 564 1110 2191 3607 8257

20 112 231 491 958 1902 3119 7156

25 99 207 441 855 1704 2786 6404

30 90 189 403 778 1558 2541 5848

40 78 164 351 672 1353 2197 5069

50 69 147 315 599 1213 1963 4536

60 63 134 288 546 1109 1790 4142

70 58 124 267 505 1028 1656 3837

80 54 116 250 471 963 1548 3590

90 51 109 237 444 908 1458 3386

100 48 104 225 421 863 1383 3213

150 39 85 185 342 707 1126 2626

200 34 73 160 295 614 974 2276

250 30 66 144 263 550 870 2036

300 27 60 132 240 503 793 1860

* Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length of tubing and n is the number of additonal fittings and/or bends. EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity; This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.

232

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Table N-5 Elevated Pressure (2 psi)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 2 psi; Pressure Drop: 1 psi (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

10 353 700 1444 2986 5670 9599 21637

25 220 444 926 1869 3615 6041 13715

30 200 405 847 1703 3305 5509 12526

40 172 351 737 1470 2870 4763 10855

50 154 314 661 1311 2572 4255 9715

75 124 257 543 1066 2108 3467 7940

80 120 249 527 1031 2042 3355 7689

100 107 222 473 920 1830 2997 6881

150 87 182 388 748 1499 2442 5624

200 75 157 338 645 1302 2111 4874

250 67 141 303 576 1167 1886 4362

300 61 129 277 525 1067 1720 3983

400 52 111 241 453 926 1487 3452

500 46 100 216 404 830 1329 3089

Table N-5A Elevated Pressure (2 psi)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 2 psi; Pressure Drop: 1.5 psi (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

10 438 855 1761 3687 6919 11782 26473

25 271 542 1129 2304 4412 7415 16781

30 247 495 1033 2098 4034 6762 15326

40 212 429 899 1810 3502 5847 13282

50 189 384 806 1614 3139 5223 11886

75 153 314 662 1311 2572 4255 9715

80 148 304 642 1268 2492 4119 9408

100 131 272 576 1131 2233 3679 8419

150 106 222 473 919 1830 2997 6881

200 91 193 411 793 1589 2592 5963

250 81 172 369 707 1424 2315 5337

300 74 157 338 644 1302 2111 4874

400 64 136 294 555 1130 1826 4224

500 56 122 264 495 1013 1631 3780

Table N-6 Elevated Pressure (5 psi)*

Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 5 psi; Pressure Drop: 3.5 psi (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) EHD 15 19 25 31 37 46 62

10 672 1304 2650 5659 10489 18080 40353

25 420 827 1699 3543 6688 11378 25580

30 382 755 1556 3228 6116 10377 23361

40 329 654 1353 2786 5310 8972 20246

50 293 586 1214 2486 4759 8015 18119

75 238 479 998 2021 3899 6530 14809

80 230 463 967 1955 3778 6320 14341

100 205 415 868 1744 3386 5646 12834

150 166 339 713 1418 2774 4600 10489

200 143 294 620 1224 2409 3977 9090

250 128 263 556 1092 2159 3553 8135

300 116 240 509 955 1974 3240 7430

400 100 208 443 858 1714 2802 6439

500 89 186 397 766 1536 2503 5762

* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

233

appendices

Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

12


SECTION

12

Gas Line Sizing Table P-1 Propane Low Pressure (Standard)*

Maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane Gas Gas Pressure: 11 inches W.C.; Pressure Drop: 0.5 W.C. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

5 99 211 456 863 1753 2830 6547

10 69 150 325 605 1247 1993 4638

15 55 121 267 490 1021 1623 3791

20 49 106 232 425 887 1404 3285

25 42 94 209 379 795 1254 2940

30 39 87 191 344 727 1143 2684

40 33 74 166 297 631 988 2327

50 30 66 149 265 566 884 2082

60 26 60 136 241 517 805 1902

70 25 57 126 222 479 745 1761

80 23 52 118 208 449 696 1647

90 22 50 112 197 424 656 1554

100 20 47 106 186 402 621 1475

150 15 36 87 143 329 506 1205

200 14 33 76 129 286 438 1045

250 12 30 68 117 256 390 934

300 11 26 62 107 234 357 854

Table P-2 Propane Medium Pressure*

Maximum Capacity of OmegaFlex TracPipe in Thousdands of BTU per Hour Propane Gas Gas Pressure: .5 psi (12-14 in. W.C.); Pressure Drop: 2.5 in. W.C. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 5 10 15 222 159 19 491 353 25 1094 782 31 2512 1863 37 3863 2749 46 6383 4496 62 14586 10330

15 131 290 642 1720 2253 3663 8443

20 114 254 559 1343 1955 3168 7317

25 102 228 501 1106 1753 2830 6547

30 93 209 459 976 1603 2580 5980

40 81 182 399 883 1391 2230 5183

50 73 164 358 825 1247 1993 4638

60 67 150 328 771 1140 1818 4236

70 62 140 304 719 1056 1682 3923

80 58 131 285 673 990 1571 3671

90 55 124 269 632 934 1481 3462

100 52 118 256 596 887 1404 3285

150 43 97 210 470 727 1143 2684

200 37 85 183 398 631 988 2327

250 33 76 164 352 566 884 2082

300 30 70 136 320 517 805 1902

Table P-3 Propane Elevated Pressure (2 psi)*

Maximum Capacity of OmegaFlex TracPipe in thousands of BTU per Hour Propane Gas Gas Pressure: 2 psi; Pressure Drop: 1 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

10 558 1106 2282 4720 8963 15174 34203

25 347 701 1464 2954 5714 9549 21680

30 316 640 1340 2692 5224 8708 19801

40 271 554 1165 2323 4537 7529 17159

50 243 496 1046 2072 4066 6726 15357

75 196 406 859 1685 3332 5480 12551

80 189 393 833 1629 3228 5303 12154

100 169 350 748 1454 2893 4738 10877

150 137 287 614 1182 2370 3860 8890

200 118 248 534 1019 2058 3337 7705

250 105 222 479 910 1845 2981 6895

300 96 203 439 829 1687 2719 6296

400 82 175 381 716 1464 2351 5457

500 72 158 342 638 1312 2101 4883

* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.

234

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Table P-3A Propane Elevated Pressure (2 psi)*

Maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane Gas Gas Pressure: 2 psi; Pressure Drop: 1.5 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

10 817 1588 3237 6838 10937 18624 41847

25 525 1041 2147 4436 6974 11721 26527

30 481 957 1978 4070 6377 10689 24227

40 419 839 1739 3553 5536 9243 20996

50 376 757 1574 3198 4962 8256 18789

75 310 628 1312 2641 4066 6726 15357

80 300 609 1275 2561 3939 6511 14872

100 269 550 1153 2305 3530 5816 13308

150 222 456 962 1903 2893 4738 10877

200 193 399 845 1661 2512 4097 9426

250 173 360 765 1495 2251 3659 8436

300 159 331 705 1372 2058 3337 7705

400 138 290 619 1198 1786 2886 6677

500 124 262 560 1078 1601 2578 5975

400 158 328 700 1356 2709 4429 10178

500 140 294 629 1210 2428 3957 9108

Table P-4 Propane Elevated Pressure (5 psi)*

Maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane Gas Gas Pressure: 5 psi; Pressure Drop: 3.5 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”

EHD 15 19 25 31 37 46 62

10 1065 2061 4189 8945 16581 28580 63788

25 664 1307 2686 5600 10572 17986 40436

30 603 1193 2459 5102 9668 16403 36928

40 520 1033 2139 4404 8394 14183 32004

50 463 926 1920 3929 7523 12670 28642

75 376 757 1577 3194 6163 10322 23409

80 363 731 1529 3090 5972 9990 22670

100 324 656 1310 2756 5352 8925 20287

150 262 535 1127 2241 4796 7271 16581

200 226 464 980 1934 4385 6287 14369

250 202 416 880 1726 3808 5616 12859

300 183 379 805 1572 3120 5122 11745

* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.

appendices

Victor/F.w. Webb stocks buderus boilers. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

12 235


SECTION

12

Gas Line Sizing Propane 10#

Table 6.3 (a) Schedule 40 Metallic Pipe SPECIAL USE: Pipe Sizing Between First Stage (High Pressure Regulator) and Second Stage (Low Pressure Regulator) Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 10.0 psi 1.0 psi 1.50 Pipe Size (inches)

Nominal Inside

1/2

3/4

1

11/4

11/2

2

21/2

3

4

Actual

0.622

0.824

1.049

1.380

1.610

2.067

2.469

3.068

4.026

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000

3,320 2,280 1,830 1,570 1,390 1,260 1,160 1,080 1,010 956 848 768 706 657 582 528 486 452 424 400 380 363 347 334 321 310 300 291 283 275 261 249 239 229 221 213 206 200 194 189

6,950 4,780 3,840 3,280 2,910 2,640 2,430 2,260 2,120 2,000 1,770 1,610 1,480 1,370 1,220 1,100 1,020 945 886 837 795 759 726 698 672 649 628 609 592 575 546 521 499 480 462 446 432 419 407 395

CapAcity in thousands of BTU per hour 124,000 77,600 40,300 26,900 13,100 85,000 53,300 27,700 18,500 9,000 68,200 42,800 22,200 14,800 7,220 58,400 36,600 19,000 12,700 6,180 51,700 32,500 16,900 11,300 5,480 46,900 29,400 15,300 10,200 4,970 43,100 27,100 14,100 9,380 4,570 40,100 25,200 13,100 8,730 4,250 37,700 23,600 12,300 8,190 3,990 35,600 22,300 11,600 7,730 3,770 31,500 19,800 10,300 6,850 3,340 28,600 17,900 9,300 6,210 3,020 26,300 16,500 8,560 5,710 2,780 24,400 15,300 7,960 5,320 2,590 21,700 13,600 7,060 4,710 2,290 19,600 12,300 6,400 4,270 2,080 18,100 11,300 5,880 3,930 1,190 16,800 10,500 5,470 3,650 1,780 15,800 9,890 5,140 3,430 1,670 14,900 9,340 4,850 3,240 1,580 14,100 8,870 4,610 3,070 1,500 13,500 8,460 4,400 2,930 1,430 12,900 8,110 4,210 2,810 1,370 12,400 7,790 4,040 2,700 1,310 12,000 7,500 3,900 2,600 1,270 11,500 7,240 3,760 2,510 1,220 11,200 7,010 3,640 2,430 1,180 10,800 6,800 3,530 2,360 1,150 10,500 6,600 3,430 2,290 1,110 10,200 6,420 3,330 2,230 1,080 9,720 6,100 3,170 2,110 1,030 9,270 5,820 3,020 2,020 982 8,880 5,570 2,890 1,930 940 8,530 5,350 2,780 1,850 903 8,220 5,160 2,680 1,790 870 1,730 840 7,940 4,980 2,590 1,670 813 7,680 4,820 2,500 789 7,450 4,670 2,430 1,620 766 7,230 4,540 2,360 1,570 745 7,030 4,410 2,290 1,530

219,000 150,000 121,000 103,000 91,500 82,900 76,300 70,900 66,600 62,900 55,700 50,500 46,500 43,200 38,300 34,700 31,900 29,700 27,900 26,300 25,000 23,900 22,800 21,900 21,100 20,400 19,800 19,200 18,600 18,100 17,200 16,400 15,700 15,100 14,500 14,000 13,600 13,200 12,800 12,400

446,000 306,000 246,000 211,000 187,000 169,000 156,000 145,000 136,000 128,000 114,000 103,000 94,700 88,100 78,100 70,800 65,100 60,600 56,800 53,700 51,000 48,600 46,600 44,800 43,100 41,600 40,300 39,100 37,900 36,900 35,000 33,400 32,000 30,800 29,600 28,600 27,700 26,900 26,100 25,400

Note: All table entries are rounded to 3 significant digits.

236

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Propane 2#

Table 6.3 (c) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 2.0 psi 1.0 psi 1.50

Pipe Size (inches) 1/2

3/4

1

11/4

11/2

2

21/2

3

4

Actual ID

0.622

0.824

1.049

1.380

1.610

2.067

2.469

3.068

4.026

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000

2,680 1,840 1,480 1,260 1,120 1,010 934 869 815 770 682 618 569 529 469 425 391 364 341 322 306 292 280 269 259 250 242 235 228 222 210 201 192 185 178 172 166 161 157 152

5,590 3,850 3,090 2,640 2,340 2,120 1,950 1,820 1,700 1,610 1,430 1,290 1,190 1,110 981 889 817 760 714 674 640 611 585 562 541 523 506 490 476 463 440 420 402 386 372 359 348 337 327 318

CapAcity in thousands of BTU per hour 99,500 62,400 32,400 21,600 10,500 68,400 42,900 22,300 14,900 7,240 54,900 34,500 17,900 11,900 5,820 47,000 29,500 15,300 10,200 4,980 41,700 26,100 13,600 9,060 4,410 37,700 23,700 12,300 8,210 4,000 34,700 21,800 11,300 7,550 3,680 32,300 20,300 10,500 7,020 3,420 30,300 19,000 9,880 6,590 3,210 28,600 18,000 9,330 6,230 3,030 25,400 15,900 8,270 5,520 2,690 23,000 14,400 7,490 5,000 2,440 21,200 13,300 6,890 4,600 2,240 19,700 12,300 6,410 4,280 2,080 17,400 10,900 5,680 3,790 1,850 15,800 9,920 5,150 3,440 1,670 14,500 9,120 4,740 3,160 1,540 13,500 8,490 4,410 2,940 1,430 12,700 7,960 4,130 2,760 1,340 12,000 7,520 3,910 2,610 1,270 11,400 7,140 3,710 2,480 1,210 10,900 6,820 3,540 2,360 1,150 10,400 6,530 3,390 2,260 1,100 9,990 6,270 3,260 2,170 1,060 9,630 6,040 3,140 2,090 1,020 9,300 5,830 3,030 2,020 985 9,000 5,640 2,930 1,960 953 8,720 5,470 2,840 1,900 924 8,470 5,310 2,760 1,840 897 8,240 5,170 2,680 1,790 873 7,830 4,910 2,550 1,700 829 7,470 4,680 2,430 1,620 791 7,150 4,490 2,330 1,550 757 6,870 4,310 2,240 1,490 727 6,620 4,150 2,160 1,440 701 1,390 677 6,390 4,010 2,080 1,340 655 6,180 3,880 2,010 635 6,000 3,760 1,950 1,300 617 5,820 3,650 1,900 1,270 600 5,660 3,550 1,840 1,230

176,000 121,000 97,100 83,100 73,700 66,700 61,400 57,100 53,600 50,600 44,900 40,700 37,400 34,800 30,800 27,900 25,700 23,900 22,400 21,200 20,100 19,200 18,400 17,700 17,000 16,400 15,900 15,400 15,000 14,600 13,800 13,200 12,600 12,100 11,700 11,300 10,900 10,600 10,300 10,000

359,000 247,000 198,000 170,000 150,000 136,000 125,000 116,000 109,000 103,000 91,500 82,900 76,300 71,000 62,000 57,000 52,400 48,800 45,800 43,200 41,100 39,200 37,500 36,000 34,700 33,500 32,400 31,500 30,500 29,700 28,200 26,900 25,800 24,800 23,900 23,000 22,300 21,600 21,000 20,400

Note: All table entries are rounded to 3 significant digits.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

237

appendices

Nominal

12


SECTION

12

Gas Line Sizing Propane 11” W.C.

Table 6.3 (d) Schedule 40 Metallic Pipe SPECIAL USE: Pipe Sizing Between Single or Second Stage (Low Pressure Regulator) and Appliance Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50 Pipe Size (inches)

Nominal Inside

1/2

3/4

1

11/4

11/2

2

21/2

3

4

Actual

0.622

0.824

1.049

1.380

1.610

2.067

2.469

3.068

4.026

Length (feet) 10 20 30 40 50 60 80 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000

291 200 160 137 122 110 101 94 89 84 74 67 62 58 51 46 42 40 37 35 33 32 30 29 28 27 26 25 25 24 23 22 21 20 19 19 18 18

608 418 336 287 255 231 212 197 185 175 155 140 129 120 107 97 89 83 78 73 70 66 64 61 59 57 55 53 52 50 48 46 44 42 40 39 38 37

1,150 787 632 541 480 434 400 372 349 330 292 265 243 227 201 182 167 156 146 138 131 125 120 115 111 107 104 100 97 95 90 86 82 79 76 74 71 69

CapAcity in thousands of BTU per hour 10,800 6,790 3,520 2,350 7,430 4,660 2,420 1,620 5,970 3,750 1,940 1,300 5,110 3,210 1,660 1,110 4,530 2,840 1,480 985 4,100 2,570 1,340 892 3,770 2,370 1,230 821 3,510 2,200 1,140 763 3,290 2,070 1,070 716 3,110 1,950 1,010 677 2,760 1,730 899 600 2,500 1,570 814 543 2,300 1,440 749 500 2,140 1,340 697 465 1,900 1,190 618 412 1,720 1,080 560 373 1,580 991 515 344 1,470 922 479 320 1,380 865 449 300 1,300 817 424 283 1,240 776 403 269 1,180 741 385 257 1,130 709 368 246 1,090 681 354 236 1,050 656 341 227 1,010 634 329 220 978 613 319 213 948 595 309 206 921 578 300 200 895 562 292 195 850 534 277 185 811 509 264 176 777 487 253 169 746 468 243 162 719 451 234 156 694 436 226 151 422 219 146 672 409 212 142 652

19,100 13,100 10,600 9,030 8,000 7,250 6,670 6,210 5,820 5,500 4,880 4,420 4,060 3,780 3,350 3,040 2,790 2,600 2,440 2,300 2,190 2,090 2,000 1,920 1,850 1,790 1,730 1,680 1,630 1,580 1,500 1,430 1,370 1,320 1,270 1,230 1,190 1,150

39,000 26,800 21,500 18,400 16,300 14,800 13,600 12,700 11,900 11,200 9,950 9,010 8,290 7,710 6,840 6,190 5,700 5,300 4,970 4,700 4,460 4,260 4,080 3,920 3,770 3,640 3,530 3,420 3,320 3,230 3,070 2,930 2,800 2,690 2,590 2,500 2,420 2,350

Note: All table entries are rounded to 3 significant digits.

238

This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Propane 10#

Table 6.3 (e) Semi-Rigid Copper Tubing SPECIAL USE: Tube Sizing Between First Stage (High Pressure Regulator) and Second Stage (Low Pressure Regulator) Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 10.0 psi 1.0 psi 1.50 Tube Size (inches)

K&L Nominal

ACR

1/4

3/8

1/2

5/8

3/4

1

11/4

11/2

2

1/2

5/8

3/4

7/8

11/8

13/8

0.375

0.500

0.625

0.750

0.875

1.125

1.375

1.625

2.125

Inside*

0.305

0.402

0.527

0.652

0.745

0.995

1.245

1.481

1.959

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000

513 352 283 242 215 194 179 166 156 147 131 118 109 101 90 81 75 70 65 62 59 56 54 51 50 48 46 45 44 42 40 38 37 35 34 33 32 31 30 29

1,060 727 584 500 443 401 369 343 322 304 270 244 225 209 185 168 155 144 135 127 121 115 111 106 102 99 96 93 90 88 83 79 76 73 70 68 66 64 62 60

CapAcity in thousands of BTU per hour 20,500 11,400 5,330 3,760 2,150 14,100 7,830 3,670 2,580 1,480 11,300 6,290 2,940 2,080 1,190 9,690 5,380 2,520 1,780 1,020 8,590 4,770 2,230 1,570 901 7,780 4,320 2,020 1,430 816 7,160 3,980 1,860 1,310 751 6,660 3,700 1,730 1,220 699 6,250 3,470 1,630 1,150 655 5,900 3,280 1,540 1,080 619 5,230 2,910 1,360 959 549 4,740 2,630 1,230 869 497 4,360 2,420 1,130 799 457 4,060 2,250 1,060 744 426 3,600 2,000 935 659 377 3,260 1,810 847 597 342 3,000 1,660 779 549 314 2,790 1,550 725 511 292 2,620 1,450 680 480 274 2,470 1,370 643 453 259 2,350 1,300 610 430 246 2,240 1,240 582 410 235 2,140 1,190 558 393 225 2,060 1,140 536 378 216 1,980 1,100 516 364 208 1,920 1,060 498 351 201 1,850 1,030 482 340 195 1,800 1,000 468 330 189 1,750 970 454 320 183 1,700 944 442 311 178 1,610 896 420 296 169 1,540 855 400 282 161 1,470 819 383 270 155 1,420 787 368 260 148 1,360 758 355 250 143 1,320 732 343 241 138 1,270 708 331 234 134 1,240 687 321 227 130 1,200 667 312 220 126 1,170 648 304 214 122

32,300 22,200 17,900 15,300 13,500 12,300 11,300 10,500 9,850 9,310 8,250 7,470 6,880 6,400 5,670 5,140 4,730 4,400 4,130 3,900 3,700 3,530 3,380 3,250 3,130 3,020 2,920 2,840 2,750 2,680 2,540 2,430 2,320 2,230 2,150 2,080 2,010 1,950 1,890 1,840

67,400 46,300 37,200 31,800 28,200 25,600 23,500 21,900 20,500 19,400 17,200 15,600 14,300 13,300 11,800 10,700 9,840 9,160 8,590 8,120 7,710 7,350 7,040 6,770 6,520 6,290 6,090 5,910 5,730 5,580 5,300 5,050 4,840 4,650 4,480 4,330 4,190 4,060 3,940 3,830

Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

239

appendices

3/8

outside

12


SECTION

12

Gas Line Sizing Propane 2#

Table 6.3 (g) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 2.0 psi 1.0 psi 1.50

Tube Size (inches) K&L Nominal

ACR

1/4

3/8

1/2

5/8

3/4

1

11/4

11/2

2

3/8

1/2

5/8

3/4

7/8

11/8

13/8

outside

0.375

0.500

0.625

0.750

0.875

1.125

1.375

1.625

2.125

Inside*

0.305

0.402

0.527

0.652

0.745

0.995

1.245

1.481

1.959

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000

413 284 228 195 173 157 144 134 126 119 105 95 88 82 72 66 60 56 53 50 47 45 43 41 40 39 37 36 35 34 32 31 30 28 27 26 26 25 24 23

852 585 470 402 356 323 297 276 259 245 217 197 181 168 149 135 124 116 109 103 97 93 89 86 82 80 77 75 72 71 67 64 61 59 57 55 53 51 50 48

CapAcity in thousands of BTU per hour 16,500 9,170 4,300 3,030 1,730 11,400 6,310 2,950 2,080 1,190 9,120 5,060 2,370 1,670 956 7,800 4,330 2,030 1,430 818 6,920 3,840 1,800 1,270 725 6,270 3,480 1,630 1,150 657 5,760 3,200 1,500 1,060 605 5,360 2,980 1,390 983 562 5,030 2,790 1,310 922 528 4,750 2,640 1,240 871 498 4,210 2,340 1,100 772 442 3,820 2,120 992 700 400 3,510 1,950 913 644 368 3,270 1,810 849 599 343 2,900 1,610 753 531 304 2,620 1,460 682 481 275 2,410 1,340 628 442 253 2,250 1,250 584 411 235 2,110 1,170 548 386 221 1,990 1,110 517 365 209 1,890 1,050 491 346 198 1,800 1,000 469 330 189 1,730 959 449 316 181 1,660 921 431 304 174 1,600 888 415 293 168 1,540 857 401 283 162 1,490 829 388 274 157 1,450 804 376 265 152 1,410 781 366 258 147 1,370 760 356 251 143 1,300 721 338 238 136 1,240 688 322 227 130 1,190 659 309 217 124 1,140 633 296 209 120 1,100 610 286 201 115 1,060 589 276 194 111 1,030 570 267 188 108 1,000 553 259 182 104 966 537 251 177 101 940 522 244 172 99

26,000 17,900 14,400 12,300 10,900 9,880 9,090 8,450 7,930 7,490 6,640 6,020 5,540 5,150 4,560 4,140 3,800 3,540 3,320 3,140 2,980 2,840 2,720 2,620 2,520 2,430 2,350 2,280 2,220 2,160 2,050 1,950 1,870 1,800 1,730 1,670 1,620 1,570 1,520 1,480

54,200 37,300 29,900 25,600 22,700 20,600 18,900 17,600 16,500 15,600 13,800 12,500 11,500 10,700 9,510 8,610 7,920 7,370 6,920 6,530 6,210 5,920 5,670 5,450 5,250 5,070 4,900 4,750 4,620 4,490 4,270 4,070 3,900 3,740 3,610 3,480 3,370 3,270 3,170 3,090

Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

240

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Propane 11” W.C.

Table 6.3 (f) Semi-Rigid Copper Tubing SPECIAL USE: Tube Sizing Between Single or Second Stage (Low Pressure Regulator) and Appliance Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50 Tube Size (inches)

K&L Nominal

ACR

1/4

3/8

1/2

5/8

3/4

1

11/4

11/2

2

1/2

5/8

3/4

7/8

11/8

13/8

0.375

0.500

0.625

0.750

0.875

1.125

1.375

1.625

2.125

Inside*

0.305

0.402

0.527

0.652

0.745

0.995

1.245

1.481

1.959

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000

45 31 25 21 19 17 16 15 14 13 11 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA

93 64 51 44 39 35 32 30 28 27 24 21 20 18 16 15 14 13 12 11 11 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA

CapAcity in thousands of BTU per hour 1,800 997 467 329 188 1,230 685 321 226 129 991 550 258 182 104 848 471 220 155 89 752 417 195 138 79 681 378 177 125 71 626 348 163 115 66 583 324 152 107 61 547 304 142 100 57 517 287 134 95 54 458 254 119 84 48 415 230 108 76 44 382 212 99 70 40 355 197 92 65 37 315 175 82 58 33 285 158 74 52 30 262 146 68 48 28 244 136 63 45 26 229 127 60 42 24 216 120 56 40 23 205 114 53 38 22 196 109 51 36 21 188 104 49 34 20 180 100 47 33 19 174 96 45 32 18 168 93 44 31 18 162 90 42 30 17 157 87 41 29 17 153 85 40 28 16 149 83 39 27 16 141 78 37 26 15 135 75 35 25 14 129 72 34 24 14 124 69 32 23 13 119 66 31 22 13 115 64 30 21 12 112 62 29 20 12 108 60 28 20 11 105 58 27 19 11 102 57 27 19 11

2,830 1,950 1,560 1,340 1,180 1,070 988 919 862 814 722 654 602 560 496 449 414 385 361 341 324 309 296 284 274 264 256 248 241 234 223 212 203 195 188 182 176 170 166 161

5,890 4,050 3,250 2,780 2,470 2,240 2,060 1,910 1,800 1,700 1,500 1,360 1,250 1,170 1,030 936 861 801 752 710 674 643 616 592 570 551 533 517 502 488 464 442 423 407 392 378 366 355 345 335

NA means a flow of less than 10,000 BTU/hr. Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.

This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

241

appendices

3/8

outside

12


SECTION

12

Gas Line Sizing Propane 10#

Table 15.1 (o) Polyethylene Plastic SPECIAL USE: Pipe Sizing Between First Stage and Second Stage Regulators Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 10 psi 1 psi 1.50 Nominal outside diameter (IPS) Pipe Size (inches)

Nominal OD

1/2

3/4

1

11/4

11/2

2

Designation

SDR 9.33

SDR 11.0

SDR 10.00

SDR 11.00

SDR 11.00

SDR 11.0

Actual ID

(0.660)

(0.860)

(1.077)

(1.328)

(1.554)

(1.943)

20,260 17,340 15,368 13,924 12,810 11,918 11,182 10,562 9,361 8,482 7,803 7,259 6,811 6,434 6,111 5,830 5,363 4,989 4,681 4,422 4,007 3,686 3,429 3,217 3,039 2,441 2,089

36,402 31,155 27,612 25,019 23,017 21,413 20,091 18,978 16,820 15,240 14,020 13,043 12,238 11,560 10,979 10,474 9,636 8,965 8,411 7,945 7,199 6,623 6,161 5,781 5,461 4,385 3,753

length (feet) 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 450 500 600 700 800 900 1000 1500 2000

2,143 1,835 1,626 1,473 1,355 1,261 1,183 1,117 990 897 826 778 721 681 646 617 567 528 495 468 424 390 363 340 322 258 221

4,292 3,673 3,256 2,950 2,714 2,525 2,369 2,238 1,983 1,797 1,653 1,539 1,443 1,363 1,294 1,235 1,136 1,057 992 937 849 781 726 682 644 517 443

CapAcity in thousands of BTU per hour 7,744 13,416 6,628 11,482 5,874 10,176 5,322 9,220 4,896 8,483 4,555 7,891 4,274 7,404 4,037 6,994 3,578 6,199 3,242 5,616 2,983 5,167 2,775 4,807 2,603 4,510 2,459 4,260 2,336 4,046 2,228 3,860 2,050 3,551 1,907 3,304 1,789 3,100 1,690 2,928 1,531 2,653 1,409 2,441 1,311 2,271 1,230 2,131 1,162 2,012 933 1,616 798 1,383

Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1 psi pressure drop. Capacities in 1000 BTU/hr. (2) Dimensions in parentheses are inside diameter.

This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition

242

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Propane 11” W.C.

Table 6.3 (k) Polyethylene Plastic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50

Pipe Size (inches) Nominal oD

1/2

3/4

1

11/4

11/2

2

Designation

SDR 9.33

SDR 11.00

SDR 11.00

SDR 10.00

SDR 11.00

SDR 11.00

actual ID

0.660

0.860

1.077

1.328

1.554

1.943

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500

340 233 187 160 142 129 119 110 103 98 87 78 72 67 60 54 50 46 43 41

680 468 375 321 285 258 237 221 207 196 173 157 145 135 119 108 99 92 87 82

3,210 2,210 1,770 1,520 1,340 1,220 1,120 1,040 978 924 819 742 683 635 563 510 469 436 409 387

5,770 3,970 3,180 2,730 2,420 2,190 2,010 1,870 1,760 1,660 1,470 1,330 1,230 1,140 1,010 916 843 784 736 695

CapAcity in thousands of BTU per hour 2,130 1,230 1,460 844 1,170 677 1,000 580 890 514 807 466 742 428 690 398 648 374 612 353 542 313 491 284 452 261 420 243 373 215 338 195 311 179 289 167 271 157 256 148

Note: All table entries are rounded to 3 significant digits.

appendices

Victor/F.w. Webb is weil mclain’s largest distributor.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

243

12


SECTION

12

Gas Line Sizing Propane 10#

Propane 11� W.C.

Table 15.1 (p) Polyethylene Plastic

Table 15.1 (q) Polyethylene Plastic

SPECIAL USE: Tube Sizing Between First Stage and Second Stage Regulators

SPECIAL USE: Tube Sizing Between First Stage and Second Stage Regulators

Gas Inlet Pressure Pressure Drop Specific Gravity

Gas Inlet Pressure Pressure Drop Specific Gravity

Undiluted Propane 10 psi 10 psi 1.50 Nominal outside diameter (CTS)

Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50 Nominal outside diameter (CTS)

Pipe Size (inches)

Pipe Size (inches)

Nominal OD

1/2

1

Nominal OD

1/2

1

Designation

SDR 7.00

SDR 11.00

Designation

SDR 7.00

SDR 11.00

Actual ID

(0.445)

(0.927)

Actual ID

(0.445)

(0.927)

length (feet) 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 450 500 600 700 800 900 1000 1500 2000

CapAcity in thousands of BTU per hour 762 5,225 653 4,472 578 3,964 524 3,591 482 3,304 448 3,074 421 2,884 397 2,724 352 2,414 319 2,188 294 2,013 273 1,872 256 1,757 242 1,659 230 1,576 219 1,503 202 1,383 188 1,287 176 1,207 166 1,140 151 1,033 139 951 129 884 121 830 114 784 92 629 79 539

Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1 psi pressure drop. Capacities in 1000 BTU/hr. (2) Dimensions in parentheses are inside diameter.

length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400

CapAcity in thousands of BTU per hour 121 829 83 569 67 457 57 391 51 347 46 314 42 289 39 269 37 252 35 238 31 211 28 191 26 176 24 164 22 154 21 145 20 138 19 132 18 121 16 113

Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 11 in. W.C. setting and a 0.5 in. W.C. pressure drop. Capacities in 1000 BTU/hr. (2) Dimensions in parentheses are inside diameter.

This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition

244

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Natural Gas Low Pressure

Table 6.2(b) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Natural Less than 2 psi 0.5 inches W.C. 0.60 PIPE Size (inches) 1/2

3/4

1

11/4

11/2

2

21/2

3

4

5

6

8

10

12

0.622

0.824

1.049

1.380

1.610

2.067

2.469

3.068

4.026

5.047

6.065

7.981

10.020

11.938

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

172 118 95 81 72 65 60 56 52 50 44 40 37 34 30 27 25 23 22 21 20 19 18 17 17 16 16 15 15 14

360 247 199 170 151 137 126 117 110 104 92 83 77 71 63 57 53 49 46 43 41 39 38 36 35 34 33 32 31 30

678 466 374 320 284 257 237 220 207 195 173 157 144 134 119 108 99 92 86 82 78 74 71 68 66 63 61 59 58 56

1,390 957 768 657 583 528 486 452 424 400 355 322 296 275 244 221 203 189 177 168 159 152 145 140 135 130 126 122 118 115

CapAcity in Cubic Feet of Gas per hour 11,300 23,100 41,800 6,400 4,020 2,090 7,780 15,900 28,700 4,400 2,760 1,430 6,250 12,700 23,000 3,530 2,220 1,150 5,350 10,900 19,700 3,020 2,900 985 17,500 9,660 4,740 2,680 1,680 873 15,800 8,760 4,290 2,430 1,520 791 14,600 8,050 3,950 2,230 1,400 728 13,600 7,490 3,670 2,080 1,300 677 12,700 7,030 3,450 1,950 1,220 635 12,000 6,640 3,260 1,840 1,160 600 10,600 5,890 2,890 1,630 1,020 532 9,650 5,330 2,610 1,480 928 482 8,880 4,910 2,410 1,360 854 443 8,260 4,560 2,240 1,270 794 412 7,320 4,050 1,980 1,120 704 366 6,630 3,670 1,800 1,020 638 331 6,100 3,370 1,650 935 587 305 5,680 3,140 1,540 870 546 283 5,330 2,940 1,440 816 512 266 5,030 2,780 1,360 771 484 251 4,780 2,640 1,290 732 459 239 4,560 2,520 1,240 699 438 228 4,360 2,410 1,180 669 420 218 4,190 2,320 1,140 643 403 209 4,040 2,230 1,090 619 389 202 3,900 2,160 1,060 598 375 195 3,780 2,090 1,020 579 363 189 3,660 2,020 992 561 352 183 3,550 1,960 963 545 342 178 3,460 1,910 937 530 333 173

67,600 46,500 37,300 31,900 28,300 25,600 23,600 22,000 20,600 19,500 17,200 15,600 14,400 13,400 11,900 10,700 9,880 9,190 8,620 8,150 7,740 7,380 7,070 6,790 6,540 6,320 6,110 5,930 5,760 5,600

139,000 95,500 76,700 65,600 58,200 52,700 48,500 45,100 42,300 40,000 35,400 32,100 29,500 27,500 24,300 22,100 20,300 18,900 17,700 16,700 15,900 15,200 14,500 14,000 13,400 13,000 12,600 12,200 11,800 11,500

252,000 173,000 139,000 119,000 106,000 95,700 88,100 81,900 76,900 72,600 64,300 58,300 53,600 49,900 44,200 40,100 36,900 34,300 32,200 30,400 28,900 27,500 26,400 25,300 24,400 23,600 22,800 22,100 21,500 20,900

399,000 275,000 220,000 189,000 167,000 152,000 139,000 130,000 122,000 115,000 102,000 92,300 84,900 79,000 70,000 63,400 58,400 54,300 50,900 48,100 45,700 43,600 41,800 40,100 38,600 37,300 36,100 35,000 34,000 33,100

1,100 1,200 1,300 1,400 1,500

14 13 12 12 11

28 27 26 25 24

53 51 49 47 45

109 104 100 96 93

164 156 150 144 139

316 301 289 277 267

503 480 460 442 426

890 849 813 781 752

1,810 1,730 1,660 1,590 1,530

3,280 3,130 3,000 2,880 2,780

5,320 5,070 4,860 4,670 4,500

10,900 10,400 9,980 9,590 9,240

19,800 18,900 18,100 17,400 16,800

31,400 30,000 28,700 27,600 26,600

1,600 1,700 1,800 1,900 2,000

11 11 10 10 NA

23 22 22 21 20

44 42 41 40 39

89 86 84 81 79

134 130 126 122 119

258 250 242 235 229

411 398 386 375 364

727 703 682 662 644

1,480 1,430 1,390 1,350 1,310

2,680 2,590 2,520 2,440 2,380

4,340 4,200 4,070 3,960 3,850

8,920 8,630 8,370 8,130 7,910

16,200 15,700 15,200 14,800 14,400

25,600 24,800 24,100 23,400 22,700

NA means a flow of less than 10,000 BTU/hr. Note: All table entries are rounded to 3 significant digits.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

245

appendices

Nominal Actual ID

12


SECTION

12

Gas Line Sizing Natural Gas 2#

Table 6.2(c) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Natural 2.0 psi 1.0 psi 0.60 PIPE Size (inches)

Nominal

1/2

3/4

1

11/4

11/2

2

21/2

3

4

Actual ID

0.622

0.824

1.049

1.380

1.610

2.067

2.469

3.068

4.026

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

1,510 1,070 869 753 673 615 569 532 502 462 414 372 344 318 279 253 232 216 203 192 182 174 166 160 154 149 144 139 135 132

3,040 2,150 1,760 1,520 1,360 1,240 1,150 1,080 1,010 934 836 751 695 642 583 528 486 452 424 401 381 363 348 334 322 311 301 292 283 275

5,560 3,930 3,210 2,780 2,490 2,270 2,100 1,970 1,850 1,710 1,530 1,370 1,270 1,170 1,040 945 869 809 759 717 681 650 622 598 576 556 538 522 507 493

CapAcity in Cubic Feet of Gas per hour 52,500 32,900 17,100 11,400 37,100 23,200 12,100 8,070 30,300 19,000 9,880 6,590 26,400 16,500 8,550 5,710 23,500 14,700 7,650 5,110 21,400 13,500 6,980 4,660 19,900 12,500 6,470 4,320 18,600 11,700 6,050 4,040 17,500 11,000 5,700 3,810 16,100 10,100 5,260 3,510 14,400 9,060 4,700 3,140 13,000 8,130 4,220 2,820 12,000 7,530 3,910 2,601 11,100 6,960 3,610 2,410 9,850 6,180 3,210 2,140 8,920 5,600 2,910 1,940 8,210 5150 2,670 1,790 7,640 4,790 2,490 1,660 7,170 4,500 2,330 1,560 6,770 4,250 2,210 1,470 6,430 4,030 2,090 1,400 6,130 3,850 2,000 1.330 5,870 3,680 1,910 1,280 5,640 3,540 1,840 1,230 5,440 3,410 1,770 1,180 5,250 3,290 1,710 1,140 5,080 3,190 1,650 1,100 4,930 3,090 1,600 1,070 4,780 3,000 1,560 1,040 4,650 2,920 1,520 1,010

92,800 65,600 53,600 46,400 41,500 37,900 35,100 32,800 30,900 28,500 25,500 22,900 21,200 19,600 17,400 15,800 14,500 13,500 12,700 12,000 11,400 10,800 10,400 9,970 9,610 9,280 8,980 8,710 8,460 8,220

189,000 134,000 109,000 94,700 84,700 77,300 71,600 67,000 63,100 58,200 52,100 46,700 43,300 40,000 35,500 32,200 29,600 27,500 25,800 24,400 23,200 22,100 21,200 20,300 19,600 18,900 18,300 17,800 17,200 16,800

1,100 1,200 1,300 1,400 1,500

125 119 114 110 106

262 250 239 230 221

468 446 427 411 396

960 917 878 843 812

1,440 1,370 1,320 1,260 1,220

2,770 2,640 2,530 2,430 2,340

4,420 4,220 4,040 3,880 3,740

7,810 7,450 7,140 6,860 6,600

15,900 15,200 14,600 14,000 13,500

1,600 1,700 1,800 1,900 2,000

102 99 96 93 91

214 207 200 195 189

382 370 358 348 339

784 759 736 715 695

1,180 1,140 1,100 1,070 1,040

2,260 2,190 2,120 2,060 2,010

3,610 3,490 3,390 3,290 3,200

6,380 6,170 5,980 5,810 5,650

13,000 12,600 12,200 11,900 11,500

Note: All table entries are rounded to 3 significant digits.

246

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Natural Gas 5#

Table 6.2(e) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Natural 5.0 psi 3.5 psi 0.60 PIPE Size (inches) 1/2

3/4

1

11/4

11/2

2

21/2

3

4

0.622

0.824

1.049

1.380

1.610

2.067

2.469

3.068

4.026

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

3,190 2,250 1,840 1,590 1,430 1,300 1,200 1,150 1,060 979 876 786 728 673 558 506 465 433 406 384 364 348 333 320 308 298 288 279 271 264

6,430 4,550 3,720 3,220 2,880 2,630 2,430 2,330 2,150 1,980 1,770 1,590 1,470 1,360 1,170 1,060 973 905 849 802 762 727 696 669 644 622 602 584 567 551

11,800 8,320 6,790 5,880 5,260 4,800 4,450 4,260 3,920 3,620 3,240 2,910 2,690 2,490 2,200 1,990 1,830 1,710 1,600 1,510 1,440 1,370 1,310 1,260 1,210 1,170 1,130 1,100 1,070 1,040

CapAcity in Cubic Feet of Gas per hour 111,000 69,700 36,200 24,200 78,600 49,300 25,600 17,100 64,200 40,300 20,900 14,000 55,600 34,900 18,100 12,100 49,700 31,200 16,200 10,800 45,400 28,500 14,800 9,860 42,000 26,400 13,700 9,130 39,300 24,700 12,800 8,540 37,000 23,200 12,100 8,050 34,200 21,400 11,100 7,430 30,600 19,200 9,950 6,640 27,400 17,200 8,940 5,960 25,400 15,900 8,270 5,520 23,500 14,700 7,650 5,100 20,800 13,000 6,760 4,510 18,800 11,800 6,130 4,090 17,300 10,900 5,640 3,760 16,100 10,100 5,250 3,500 15,100 9,480 4,920 3,290 14,300 8,950 4,650 3,100 13,600 8,500 4,420 2,950 12,900 8,110 4,210 2,810 12,400 7,770 4,030 2,690 11,900 7,460 3,880 2,590 11,500 7,190 3,730 2,490 11,100 6,940 3,610 2,410 10,700 6,720 3,490 2,330 10,400 6,520 3,380 2,260 10,100 6,330 3,290 2,190 9,810 6,150 3,200 2,130

196,000 139,000 113,000 98,200 87,900 80,200 74,300 69,500 65,500 60,400 54,000 48,500 44,900 41,500 36,700 33,300 30,600 28,500 26,700 25,200 24,000 22,900 21,900 21,000 20,300 19,600 18,900 18,400 17,800 17,300

401,000 283,000 231,000 200,000 179,000 164,000 151,000 142,000 134,000 123,000 110,000 98,900 91,600 84,700 74,900 67,800 62,400 58,100 54,500 51,500 48,900 46,600 44,600 42,900 41,300 39,900 38,600 37,400 36,400 35,400

1,100 1,200 1,300 1,400 1,500

250 239 229 220 212

524 400 478 460 443

987 941 901 866 834

2,030 1,930 1,850 1,780 1,710

3,030 2,900 2,770 2,660 2,570

5,840 5,580 5,340 5,130 4,940

9,320 8,890 8,510 8,180 7,880

16,500 15,700 15,000 14,500 13,900

33,600 32,000 30,700 29,500 28,400

1,600 1,700 1,800 1,900 2,000

205 198 192 186 181

428 414 401 390 379

806 780 756 734 714

1,650 1,600 1,550 1,510 1,470

2,480 2,400 2,330 2,260 2,200

4,770 4,620 4,480 4,350 4,230

7,610 7,360 7,140 6,930 6,740

13,400 13,000 12,600 12,300 11,900

27,400 26,500 25,700 25,000 24,300

Note: All table entries are rounded to 3 significant digits.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

247

appendices

Nominal Actual ID

12


SECTION

12

Gas Line Sizing Natural Gas Low Pressure

Table 6.2(g) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity

Natural Less than 2.0 psi 0.5 inches W.C. 0.60 PIPE Size (inches)

Nominal

k&l

1/4

3/8

1/2

5/8

3/4

1

11/4

11/2

2

Actual ID

acr

3/8

1/2

5/8

3/4

7/8

11/8

13/8

Outside

0.375

0.500

0.625

0.750

0.875

1.125

1.375

1.625

2.125

Inside*

0.305

0.402

0.527

0.652

0.745

0.995

1.245

1.481

1.959

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

27 18 15 13 11 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA

55 38 30 26 23 21 19 18 17 16 14 13 12 11 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA

CapAcity in Cubic Feet of Gas per hour 1,060 590 276 195 111 730 406 190 134 77 586 326 152 107 61 502 279 131 92 53 445 247 116 82 47 403 224 105 74 42 371 206 96 68 39 345 192 90 63 36 324 180 84 59 34 306 170 79 56 32 271 151 70 50 28 245 136 64 45 26 226 125 59 41 24 210 117 55 39 22 186 103 48 34 20 169 94 44 31 18 155 86 40 28 16 144 80 38 26 15 135 75 35 25 14 128 71 33 23 13 122 68 32 22 13 116 64 30 21 12 111 62 29 20 12 107 59 28 20 11 103 57 27 19 11 99 55 26 18 10 96 53 25 18 10 93 52 24 17 NA 90 50 24 17 NA 88 49 23 16 NA

1,680 1,150 925 791 701 635 585 544 510 482 427 387 356 331 294 266 245 228 214 202 192 183 175 168 162 156 151 147 143 139

3,490 2,400 1,930 1,650 1,460 1,320 1,220 1,130 1,060 1,000 890 806 742 690 612 554 510 474 445 420 399 381 365 350 338 326 315 306 297 289

1,100 1,200 1,300 1,400 1,500

NA NA NA NA NA

NA NA NA NA NA

NA NA NA NA NA

15 15 14 13 13

22 21 20 19 18

46 44 42 41 39

84 80 76 73 71

132 126 120 116 111

274 262 251 241 232

1,600 1,700 1,800 1,900 2,000

NA NA NA NA NA

NA NA NA NA NA

NA NA NA NA NA

13 12 12 11 11

18 17 17 16 16

38 37 36 35 34

68 66 64 62 60

108 104 101 98 95

224 217 210 204 199

NA means a flow of less than 10 cfh. Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

248

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Natural Gas 2#

Table 6.2(j) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity

Natural 2.0 psi 1.0 psi 0.60 Tube Size (inches)

k&l Nominal

1/4

3/8

1/2

5/8

3/4

1

11/4

11/2

2

3/8

1/2

5/8

3/4

7/8

11/8

13/8

Outside

0.375

0.500

0.625

0.750

0.875

1.125

1.375

1.625

2.125

0.527

0.652

0.745

0.995

1.245

1.481

1.959

CapAcity in Cubic Feet of Gas per hour 9,820 5,450 2,550 1,800 1,030 6,750 3,750 1,760 1,240 708 5,420 3,010 1,410 993 568 4,640 2,580 1,210 850 486 4,110 2,280 1,070 754 431 3,730 2,070 969 683 391 3,430 1,900 891 628 359 3,190 1,770 829 584 334 2,990 1,660 778 548 314 2,830 1,570 735 518 296 2,500 1,390 651 459 263 2,270 1,260 590 416 238 2,090 1,160 543 383 219 1,940 1,080 505 356 204 1,720 956 448 315 181 1,560 866 406 286 164 1,430 797 373 263 150 1,330 741 347 245 140 1,250 696 326 230 131 1,180 657 308 217 124 1,120 624 292 206 118 1,070 595 279 196 112 1,030 570 267 188 108 986 548 256 181 103 950 528 247 174 100 917 510 239 168 96 888 493 231 163 93 861 478 224 158 90 836 464 217 153 88 813 452 211 149 85

15,500 10,600 8,550 7,310 6,480 5,870 5,400 5,030 4,720 4,450 3,950 3,580 3,290 3,060 2,710 2,460 2,260 2,100 1,970 1,870 1,770 1,690 1,620 1,550 1,500 1,450 1,400 1,360 1,320 1,280

32,200 22,200 17,800 15,200 13,500 12,200 11,300 10,500 9,820 9,280 8,220 7,450 6,850 6,380 5,650 5,120 4,710 4,380 4,110 3,880 3,690 3,520 3,370 3,240 3,120 3,010 2,920 2,830 2,740 2,670

acr

0.305

0.402

245 169 135 116 103 93 86 80 75 71 63 57 52 49 43 39 36 33 31 30 28 27 26 25 24 23 22 22 21 20

506 348 279 239 212 192 177 164 154 146 129 117 108 100 89 80 74 69 65 61 58 55 53 51 49 47 46 44 43 42

1,100 1,200 1,300 1,400 1,500

19 18 18 17 16

40 38 36 35 34

81 77 74 71 68

142 135 129 124 120

201 192 183 176 170

429 409 392 376 363

772 737 705 678 653

1,220 1,160 1,110 1,070 1,030

2,540 2,420 2,320 2,230 2,140

1,600 1,700 1,800 1,900 2,000

16 15 15 14 14

33 31 30 30 29

66 64 62 60 59

116 112 108 105 102

164 159 154 149 145

350 339 329 319 310

630 310 592 575 559

994 962 933 906 881

2,070 2,000 1,940 1,890 1,830

Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

249

appendices

Inside* Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

12


SECTION

12

Gas Line Sizing Natural Gas 5#

Table 6.2(l) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity

Natural 5.0 psi 3.5 psi 0.60 PIPE Size (inches)

k&l Nominal

1/4

3/8

1/2

5/8

3/4

1

11/4

11/2

2

3/8

1/2

5/8

3/4

7/8

11/8

13/8

Outside

0.375

0.500

0.625

0.750

0.875

1.125

1.375

1.625

2.125

0.652

0.745

0.995

acr

Inside*

0.305

0.402

0.527

1.245

1.481

1.959

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

511 351 382 241 214 194 178 166 156 147 130 118 109 101 90 81 75 69 65 62 58 56 53 51 49 48 46 45 43 42

1,050 724 582 498 441 400 368 342 321 303 269 243 224 208 185 167 154 143 134 127 121 115 110 106 102 98 95 92 90 87

CapAcity in Cubic Feet of Gas per hour 20,400 11,400 5,320 3,750 2,140 14,000 7,800 3,650 2,580 1,470 11,300 6,270 2,930 2,070 1,180 9,660 5,360 2,510 1,770 1,010 8,560 4,750 2,230 1,570 898 7,750 4,310 2,020 1,420 813 7,130 3,960 1,860 1,310 748 6,640 3,690 1,730 1,220 696 6,230 3,460 1,620 1,140 653 5,880 3,270 1,530 1,080 617 5,210 2,900 1,360 955 547 4,720 2,620 1,230 866 495 4,350 2,410 1,130 796 456 4,040 2,250 1,050 741 424 3,580 1,990 932 657 376 3,250 1,800 844 595 340 2,990 1,660 777 547 313 2,780 1,540 722 509 291 2,610 1,450 678 478 273 2,460 1,370 640 451 258 2,340 1,300 608 429 245 2,230 1,240 580 409 234 2,140 1,190 556 392 224 2,050 1,140 534 376 215 1,980 1,100 514 362 207 1,910 1,060 497 350 200 1,850 1,030 481 339 194 1,790 1,000 466 328 188 1,740 967 452 319 182 1,690 940 440 310 177

32,200 22,200 17,800 15,200 13,500 12,200 11,200 10,500 9,820 9,270 8,220 7,450 6,850 6,370 5,650 5,120 4,170 4,380 4,110 3,880 3,690 3,520 3,370 3,240 3,120 3,010 2,910 2,820 2,740 2,670

67,100 46,100 37,000 31,700 28,100 25,500 23,400 21,800 20,400 19,300 17,100 15,500 14,300 13,300 11,800 10,700 9,810 9,120 8,560 8,090 7,680 7,330 7,020 6,740 6,490 6,270 6,070 5,880 5,710 5,560

1,100 1,200 1,300 1,400 1,500

40 38 37 35 34

83 79 76 73 70

169 161 154 148 143

295 281 269 259 249

418 399 382 367 353

893 852 816 784 755

1,610 1,530 1,470 1,410 1,360

2,530 2,420 2,320 2,220 2,140

5,280 5,040 4,820 4,630 4,460

1,600 1,700 1,800 1,900 2,000

33 32 31 32 29

68 65 63 62 60

138 133 129 125 122

241 233 226 219 213

341 330 320 311 302

729 705 684 664 646

1,310 1,270 1,230 1,200 1,160

2,070 2,000 1,940 1,890 1,830

4,310 4,170 4,040 3,930 3,820

Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

250

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Natural Gas Low Pressure

Table 6.2(s) Polyethylene Plastic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Natural Less than 2 psi 0.5 inches in W.C. 0.60 pipe Size (inches)

Nominal OD

1/2

3/4

1

11/4

11/2

2

Designation

SDR 9.33

SDR 11.00

SDR 11.00

SDR 10.00

SDR 11.00

SDR 11.00

Actual ID

0.660

0.860

1.077

1.328

1.554

1.943

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500

201 138 111 95 84 76 70 65 61 58 51 46 43 40 35 32 29 27 26 24

403 277 222 190 169 153 140 131 123 116 103 93 86 80 71 64 59 55 51 48

CapAcity in Cubic Feet of Gas per hour 1,900 1,260 726 1,310 865 499 1,050 695 401 898 594 343 796 527 304 721 477 276 663 439 254 617 409 236 579 383 221 547 362 209 485 321 185 439 291 168 404 268 154 376 249 144 333 221 127 302 200 115 278 184 106 258 171 99 242 160 93 229 152 88

3,410 2,350 1,880 1,610 1,430 1,300 1,190 1,110 1,040 983 871 789 726 675 598 542 499 464 435 411

appendices

12 Note: All table entries are rounded to 3 significant digits.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

251


SECTION

12

Gas Line Sizing Natural Gas 2#

Table 6.2(t) Polyethylene Plastic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity

Natural 2.0 psi 1.0 psi 0.60 pipe Size (inches)

Nominal OD

1/2

3/4

1

11/4

11/2

2

Designation

SDR 9.33

SDR 11.00

SDR 11.00

SDR 10.00

SDR 11.00

SDR 11.00

Actual ID

0.660

0.860

1.077

1.328

1.554

1.943

Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000

1,860 1,280 1,030 878 778 705 649 603 566 535 474 429 395 368 326 295 272 253 237 224 213 203 194 187 180 174 168 163 158 154

3,720 2,560 2,050 1,760 1,560 1,410 1,300 1,210 1,130 1,070 949 860 791 736 652 591 544 506 475 448 426 406 389 374 360 348 336 326 317 308

17,600 12,100 9,690 8,300 7,350 6,660 6,130 5,700 5,350 5.050 4,480 4,060 3,730 3,470 3,080 2,790 2,570 2,390 2,240 2,120 2,010 1,920 1,840 1,760 1,700 1,640 1,590 1,540 1,500 1,450

31,600 21,700 17,400 14,900 13,200 12,000 11,000 10,200 9,610 9,080 8,050 7,290 6,710 6,240 5,530 5,010 4,610 4,290 4,020 3,800 3,610 3,440 3,300 3,170 3,050 2,950 2,850 2,770 2,690 2,610

1,100 1,200 1,300 1,400 1,500

146 139 134 128 124

293 279 267 257 247

528 504 482 463 446

915 873 836 803 773

1,380 1,320 1,260 1,210 1,170

2,480 2,370 2,270 2,180 2,100

1,600 1,700 1,800 1,900 2,000

119 115 112 109 106

239 231 224 218 212

431 417 404 393 382

747 723 701 680 662

1,130 1,090 1,060 1,030 1,000

2,030 1,960 1,900 1,850 1,800

Note: All table entries are rounded to 3 significant digits.

252

CapAcity in Cubic Feet of Gas per hour 11,600 6,710 7,990 4,610 6,420 3,710 5,490 3,170 4,870 2,810 4,410 2,550 4,060 2,340 3,780 2,180 3,540 2,050 3,350 1,930 2,970 1,710 2,690 1,550 2,470 1,430 2,300 1,330 2,040 1,180 1,850 1,070 1,700 981 1,580 913 1,480 856 1,400 809 1,330 768 1,270 733 1,220 702 1,170 674 1,130 649 1,090 627 1,050 607 1,020 588 990 572 963 556

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

Gas Equipment Catalog

victormfg.com


SECTION

12

Gas Line Sizing

Natural Gas Low Pressure

Natural Gas 2#

Table 6.2 (u) Table 6.2 (v) Polyethylene Plastic Tubing Polyethylene Plastic Tubing Gas Inlet Pressure Pressure Drop Specific Gravity

Natural Less than 2.0 psi 0.3 inches W.C. 0.60

Gas Inlet Pressure Pressure Drop Specific Gravity

Natural Less than 2.0 psi 0.5 inches W.C. 0.60

Plastic tubing size (CTS)*

Plastic tubing size (CTS)*

Pipe Size (inches)

Pipe Size (inches)

Nominal OD

1/2

3/4

Nominal OD

1/2

3/4

Designation

SDR 7.00

SDR 11.00

Designation

SDR 7.00

SDR 11.00

Actual ID

0.445

0.927

Actual ID

(0.445)

(0.927)

length (feet) 10 20 30 40 50 60 70 80 90 100

CapAcity in Cubic Feet of GAS per hour 372 54 256 37 205 30 176 26 156 23 141 21 130 19 121 18 113 17 107 16

125 150 175 200

14 13 12 11

95 86 79 74

225 250 275 300

10 NA NA NA

350 400 450 500

NA NA NA NA

length (feet) 10 20 30 40 50 60 70 80 90 100

CapAcity in thousands of BTU per hour 490 72 337 49 271 39 232 34 205 30 186 27 171 25 159 23 149 22 141 21

125 150 175 200

18 17 15 14

125 113 104 97

69 65 62 59

225 250 275 300

13 12 11 11

91 86 82 78

54 51 47 45

350 400 450 500

10 NA NA NA

72 67 63 59

appendices

* CTS = Copper tube size. NA means a flow of less than 10 cfh. Note: All table entries are rounded to 3 significant digits.

This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

253

12



GAS INDEX

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004



Gas Index A Accessories, Meters & Meter Accessories . . . . . . . . 89 Adapters, Connectors & Fittings, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 64-68 Aluminum Tubing, Gas Heating . . . . . . . . . . . . . . . 166 Anodes, Cylinders, Tanks & Accessories . . . . . . . . . 98 Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 Gas Line Sizing . . . . . . . . . . . . . . . . . . . . . 231-253 Leak Checking Method . . . . . . . . . . . . . . . . 228-230 Liquid Volume Tables & Temperature Correction Factors . . . . . . . . . . . . . . . . . . 225-226 LP Container Requirements . . . . . . . . . . . . 213-222 Orifice Sizing & Propertites of LP Gases . . 223-224 Vaporizer & Electrical Requirements . . . . . . . . . 227 Application Diagrams, Valves & Accessories . . . 75-77 ASME & Dot Cylinders, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . .90-93 ASME Tanks, Cylinders, Tanks & Accessories . . 94-95

B Ball Valves, Valves & Accessories . . . . . . . . . . . 49-52 Barbed Hose Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Black Iron Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 140-143 Brackets, Regulators & Accessories . . . . . . . . . . . . 10 Bulk Hose, Gas Pipe, Tubing & Fittings . . . . . . . . . 123 Bypass Valves, Pumps & Compressors . . . . . 193-194

C Chemicals, Tools & Chemicals . . . . . . . . . . . . . . . . 211 Coated Copper Tubing, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Compressor Kits, Pumps & Compressors . . . . . . . 179 Compressor Selection Tables, Pumps & Compressors . . . . . . . . . . . . . . . . . . . . 192 Compressors, Pumps & Compressors . . . . . . . . . . 191 Continental Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 129-133 Copper Tubing, Gas Pipe, Tubing & Fittings . . . . . 122 Counter Strike, Gas Pipe, Tubing & Fittings . . . . . . 119 Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . 90 Anodes, Cylinders . . . . . . . . . . . . . . . . . . . . . . . . 98 ASME & Dot Cylinders . . . . . . . . . . . . . . . . . . 90-93 ASME Replacement Parts, . . . . . . . . . . . . . . . . . 101 ASME Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . 94-95 Cylinder Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . 96 Cylinder Inverters . . . . . . . . . . . . . . . . . . . . . . . . . 96 Cylinder Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . 90

Cylinder Vice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Hand Trucks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Methanol Injector . . . . . . . . . . . . . . . . . . . . . . . . . 97 Motor Fuel Cylinders . . . . . . . . . . . . . . . . . . . . . . 91 OPD Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Pipe Wrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Scales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Technical Information . . . . . . . . . . . . . . . . . . 98-101 Temperature Monitoring System . . . . . . . . . . . . . . 95 Cylinder & Service Valves, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 30-32 Cylinder Cabinets, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . 96 Cylinder Gauges, Gauges . . . . . . . . . . . . . . . 107-115 Cylinder Inverters, Cylinders, Tanks & Accessories . . . 96 Cylinder Pads, Cylinders, Tanks & Accessories . . . . 92 Cylinder Vice, Cylinders, Tanks & Accessories . . . . 96

D Decals & Signs, Paint & Supplies . . . . . . . . . . 104-106 Disconnects, Miscellaneous Equipment . . . . . . . . . 209 Dormont Connectors, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 134-136

E Excess Flow Valves, Valves & Accessories . . . . 53-61

F Filler Valves, Valves & Accessories . . . . . . . . . . . . . 60 Fireplace Products, Miscellaneous Equipment . . . 210 Fittings, Regulators & Accessories . . . . . . . . . . . . . 8-9 Flex Connectors, Pumps & Compressors . . . . . . . 177 Flow Meters, Pumps & Compressors . . . . . . . . . . . 177 Forged Steel Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 144-148

G Gas Conversion Burners, Miscellaneous Equipment . . . . . . . . . . . . . . . . . . 207 Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Aluminum Tubing . . . . . . . . . . . . . . . . . . . . . . . . 166 Gas Leak System . . . . . . . . . . . . . . . . . . . . . . . . 173 Gas Orifices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Gas Valve Pressure Regulators . . . . . . . . . . . . . 169 Gas Valves . . . . . . . . . . . . . . 155-158, 160-162, 169 Hot Surface Igniters . . . . . . . . . . . . . . . . . . 170-172 Ignition & Pilot Modules . . . . . . . . . . . . . . . 149-153 Ignitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Pilot Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Pilot Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

i


Gas Index G

I

Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Pilots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159, 163 Retrofit Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Thermocouple & Thermopiles . . . . . . . . . . .163-164 Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Water Feed Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Water Heater Controls . . . . . . . . . . . . . . . . 154-155 Water Safety Valves . . . . . . . . . . . . . . . . . . . . . . 173 Gas Leak System, Gas Heating . . . . . . . . . . . . . . . 173 Gas Lights, Miscellaneous Equipment . . . . . . . . . . 210 Gas Line Sizing, Appendices . . . . . . . . . . . . . 231-253 Gas Orifices, Gas Heating . . . . . . . . . . . . . . . . . . . 166 Gas Outlet Boxes, Miscellaneous Equipment . . . . 209 Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . 118 Barbed Hose Fittings . . . . . . . . . . . . . . . . . . . . . 139 Black Iron Fittings . . . . . . . . . . . . . . . . . . . . 140-143 Bulk Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Coated Copper Tubing . . . . . . . . . . . . . . . . . . . . 122 Continental Fittings . . . . . . . . . . . . . . . . . . . 129-133 Copper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Counter Strike . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Dormont Connectors . . . . . . . . . . . . . . . . . 134-136 Forged Steel Fittings . . . . . . . . . . . . . . . . . 144-148 Lyall Piping Systems . . . . . . . . . . . . . . . . . . 124-128 LycoFit Mechanical Fittings . . . . . . . . . . . . . . . . 124 LycoFit Tapping Tees . . . . . . . . . . . . . . . . . . . . . 126 LycoFit Installation Tools . . . . . . . . . . . . . . . . . . . 127 LycoRing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 SAE Fittings . . . . . . . . . . . . . . . . . . . . . . . . 137-138 Sediment Traps . . . . . . . . . . . . . . . . . . . . . . . . . 123 TracPipe . . . . . . . . . . . . . . . . . . . . . . . . . . . 118-121 Underground PE Pipe . . . . . . . . . . . . . . . . . . . . . 123 Gas Valve Pressure Regulators, Gas Heating . . . . 169 Gas Valves, Gas Heating . . . . . 155-158, 160-162, 169 Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Cylinder Gauges . . . . . . . . . . . . . . . . . . . . . 107-115 Pressure Gauges . . . . . . . . . . . . . . . . . . . . . . . . 117 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . 116 Tank Gauges . . . . . . . . . . . . . . . . . . . . . . . 107-115 Gauge Products, Regulators & Accessories . . . . . . . 9 Generators, Miscellaneous Equipment . . . . . 205-206 Globe & Angle Valves, Valves & Accessories . . . 44-48

Ignition & Pilot Modules, Gas Heating . . . . . . 149-153 Ignitors, Gas Heating . . . . . . . . . . . . . . . . . . . . . . . 152 Internal Vales & Accessories, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 62-63

H Hand Trucks, Cylinders, Tanks & Accessories . . . . . 97 Hose Reels, Pumps & Compressors . . . . . . . 175-176 Hot Surface Igniters, Gas Heating . . . . . . . . . 170-172

ii

Gas Equipment Catalog

L Leak Checking Method, Appendices . . . . . . . 228-230 Leak Detectors, Tools & Chemicals . . . . . . . . . . . . 211 Lighters, Tools & Chemicals . . . . . . . . . . . . . . . . . . 211 Liquid Volume Tables & Temperature Correction Factors, Appendices . . . . . . . . . . 225-226 LP Container Requirements, Appendices . . . 213-222 Lyall Piping Systems, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 124-128 Lyco Fittings, Gas Pipe, Tubing & Fittings . . . 124-128 LycoFit Mechanical Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 124 LycoFit Tapping Tees, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 126 LycoFit Installation Tools, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 127 LycoRing, Gas Pipe, Tubing & Fittings . . . . . . . . . . 128

M Manifolds, Meters & Meter Accessories . . . . . . . . . . 88 Manifolds, Regulators & Accessories . . . . . . . . . . . . 10 Meters & Meter Accessories . . . . . . . . . . . . . . . . . . . 86 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Meters Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86-87 Meters Bars, Meters & Meter Accessories . . . . . . . . 89 Meters, Meters & Meter Accessories . . . . . . . . . 86-87 Methanol Injector, Cylinders, Tanks & Accessories . 97 Miscellaneous Equipment . . . . . . . . . . . . . . . . . . . 207 Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Fireplace Products . . . . . . . . . . . . . . . . . . . . . . . 210 Gas Conversion Burners . . . . . . . . . . . . . . . . . . 207 Gas Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 Gas Outlet Boxes . . . . . . . . . . . . . . . . . . . . . . . . 209 Generators . . . . . . . . . . . . . . . . . . . . . . . . . 205-206 Vaporizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Miscellanous Equipment, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 69-74 Motor Fuel Cylinders, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . . 91 Motors, Pumps & Compressors . . . . . . . . . . . 195-197 Multivalve Assemblies, Valves & Accessories . . 33-36

victormfg.com


Gas Index O OPD Tools, Cylinders, Tanks & Accessories . . . . . . 97 Orifice Sizing & Propertites of LP Gases, Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . 223-224

P Paint & Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Decals & Signs . . . . . . . . . . . . . . . . . . . . . . 104-106 Tank Paint & Supplies . . . . . . . . . . . . . . . . . 102-103 Pigtails, Regulators & Accessories . . . . . . . . . . . . . 7-8 Pilot Burners, Gas Heating . . . . . . . . . . . . . . . . . . . 167 Pilot Kits, Gas Heating . . . . . . . . . . . . . . . . . . . . . . 168 Pilots, Gas Heating . . . . . . . . . . . . . . . . . . . . . 163, 168 Pipe Wrap, Cylinders, Tanks & Accessories . . . . . . . 98 POL Fittings, Regulators & Accessories . . . . . . . . . . 10 Pressure Gauges, Gauges . . . . . . . . . . . . . . . . . . . 117 Pressure Relief Valves & Relief Valve Manifolds, Valves & Accessories . . . . . . . . . . . . . . . . . . . . . 37-43 Propane Flare, Tools & Chemicals . . . . . . . . . . . . . 211 Propane Pumps, Pumps & Compressors . . . . 185-190 Pumps & Compressors . . . . . . . . . . . . . . . . . . . . . 175 Bypass Valves . . . . . . . . . . . . . . . . . . . . . . 193-194 Compressor Kits . . . . . . . . . . . . . . . . . . . . . . . . . 179 Compressor Selection Tables . . . . . . . . . . . . . . . 192 Compressors . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Flex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . 177 Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Hose Reels . . . . . . . . . . . . . . . . . . . . . . . . . 175-176 Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195-197 Positive Displacement Meters, . . . . . . . . . . . . . 174 Propane Pumps . . . . . . . . . . . . . . . . . . . . . 185-190 Pump Station Kits . . . . . . . . . . . . . . . . . . . . 180-184 Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . 197-204 Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Swivel Connectors . . . . . . . . . . . . . . . . . . . . . . . 178 Pump Station Kits, Pumps & Compressors . . 180-184

Repair Parts, Pumps & Compressors . . . . . . 197-204 Replacement Parts, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . 101 Replacement Parts, Gauges . . . . . . . . . . . . . . . . . 116 Retrofit Kits, Gas Heating . . . . . . . . . . . . . . . . . . . . 159

S SAE Fittings, Gas Pipe, Tubing & Fittings . . . 137-138 Scales, Cylinders, Tanks & Accessories . . . . . . . . . . 96 Sediment Traps, Gas Pipe, Tubing & Fittings . . . . . 123 Strainers, Pumps & Compressors . . . . . . . . . . . . . 177 Swivel Connectors, Pumps & Compressors . . . . . . 178

T Tank Gauges, Gauges . . . . . . . . . . . . . . . . . . 107-115 Tank Paint & Supplies, Paint & Supplies . . . . 102-103 Technical Information, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . .98-101 Temperature Monitoring System, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . 95 Test Gauge Kit, Tools & Chemicals . . . . . . . . . . . . 211 Test Kits, Tools & Chemicals . . . . . . . . . . . . . . . . . 212 Thermocouple & Thermopiles, Gas Heating . 163-164 Thermostats, Gas Heating . . . . . . . . . . . . . . . . . . . 159 Tools & Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . 211 Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Leak Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Lighters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Propane Flare . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Test Gauge Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Test Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 Tools, Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . 165 TracPipe, Gas Pipe, Tubing & Fittings . . . . . . 118-121

U Underground PE Pipe, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 123

R

V

Regulators & Accessories . . . . . . . . . . . . . . . . . . . . . 1 Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 Gauge Products . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1 Pigtails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 POL Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Regulator Accessories . . . . . . . . . . . . . . . . . . . . . . 6 Regulators . . . . . . . . . . . . . . . . . . . . . . . . 1-5, 11-29 Regulator Accessories, Regulators & Accessories . . . 6 Regulators, Regulators & Accessories . . . . . 1-5, 11-29 Repair Kits, Valves & Accessories . . . . . . . . . . . 78-85

Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . . 30 Adapters, Connectors & Fittings . . . . . . . . . . . 64-68 Application Diagrams . . . . . . . . . . . . . . . . . . . 75-77 Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 49-52 Cylinder & Service Valve . . . . . . . . . . . . . . . . 30-32 Excess Flow Valve . . . . . . . . . . . . . . . . . . . . . 53-61 Filler Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Globe & Angle Valves . . . . . . . . . . . . . . . . . . . 44-48 Internal Vales & Accessories . . . . . . . . . . . . . 62-63 Miscellanous Equipment, . . . . . . . . . . . . . . . . 69-74 Multivalve Assemblies . . . . . . . . . . . . . . . . . . 33-36 Pressure Relief Valves & Relief Valve Manifolds 37-43

TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004

iii


Gas Index V Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . . 30 Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . 78-85 Vapor Equalizing Valves . . . . . . . . . . . . . . . . . . . . 60 Vapor Equalizing Valves, Valves & Accessories . . . . 60 Vaporizer & Electrical Requirements, Appendices . 227 Vaporizers, Miscellaneous Equipment . . . . . . . . . . 208

W Water Feed Kit, Gas Heating . . . . . . . . . . . . . . . . . 173 Water Heater Controls, Gas Heating . . . . . . . 154-155 Water Safety Valves, Gas Heating . . . . . . . . . . . . . 173

iv

Gas Equipment Catalog

victormfg.com


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.