Issuu on Google+

force668LM

manual


manual – force669LM

MANUAL  CONNECTING  POWER  SUPPLY  FORCE668LM  SLIDE  BOLT  

Unscrew  4  torxscrews  in  de  ForceIQ  control  box  and  put  the  control  board  upside  down  

Plug  the  power  supply  connectors  onto  the  main  board  (will   only  fit  one  way)  

take  the  power  supply  out   of  the  box  

Snap  the  power  supply  onto  the  plasRc   rail  of  the  circuitboard  housing  

Replace  the  control  box  housing  in  the  main  control   box  and  Rghten  the  4  torx  screws  

www.flexiforce.com

2


manual – force669LM

ConnecRng  LM668  to  Force  IQ  control  box.  If  lock  works  the   wrong  way  round  then  swap  KL14  and  KL15    

www.flexiforce.com

3


manual – force669LM SPECIAL  SETUP    

 PROGRAM  LOCK  668LM  IN  FORCE  IQ  

SPRECIAL  SETUP   AUTO  CLOSE  

SPECIAL  SETUP   AUTO  OPEN  

SPECIAL  SETUP   PARTIAL  OPEN  

SPECIAL  SETUP   RELAYS  

RELAY  1   INACTIVE  

R1  TYPE   INACTIVE  

R1  TYPE   END  POS.  

R1  TYPE     MOVEMENT  

R1  TYPE   EL.LOCK  

MODE     LOCK  OPEN  

PRERUN                                1  SEC  

CONFIRM:SAVE   OTHER  KEY:  ESC.  

www.flexiforce.com

4


manual – force669LM

MODE     LOCK  OPEN  

PRERUN                                1  SEC  

CONFIRM:SAVE   OTHER  KEY:  ESC.  

 RELAY  1   EL.LOCK  

RELAY  2   INACTIVE  

R2  TYPE   INACTIVE  

R2  TYPE   END  POS.  

R2  TYPE     MOVEMENT  

R2  TYPE   EL.LOCK  

MODE     LOCK  OPEN  

MODE   LOCK  CLOSE  

CONFIRM:SAVE   OTHER  KEY:  ESC.  

 RELAY  2   EL.LOCK  

SPECIAL  SETUP   RELAYS  

www.flexiforce.com

BACK  TO  MAIN  MENU  

5



force668LM