FiberConnect®
FiberTech ®
FiberSwitch ®
FiberSplit®
Marine cables
265
FiberConnect® Universal cable with functional integrity 90 min
Outer jacket Out Strain relief elements / Str Out Outer fire protection barrier Rip cord
Fiber optic cables (SM / MM)
rodent-protected
Inner fire protection barrier Inn Loose tube, gel-filled Loo
GL U-D(ZN)BH n… FS
Functional integrity in the event of fire
Order no.
84 040 Q Q Q Q 222 ZGELO
Standardisation
IEC 60794-2
for at least 90 minutes
Description
Mechanical properties
Non-metallic, light and flexible cable with approval by Germani-
Min. bending radius static dynamic
scher Lloyd and Det Norske Veritas (DNV).
15 × outer diameter 20 × outer diameter
For fixed installation on ships and offshore facilities in safety-
Max. pull force
2500 N
related areas.
Max. crush resistance
3000 N/dm
Resistance to impacts
10 impacts/2 Nm
Composition Cable core
Loose tube, gel-filled
Fire performance
Inner fire protection barrier
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
multifunctional, reinforced glass rovings
Smoke density
IEC 61034
as non-metallic strain relief elements
Absence of halogen IEC 60754-1
and rodent protection
Acidity of combus-
Cable jacket
Halogen-free, flame-retardant material
tion gases
Colour of jacket
O orange
Armour
IEC 60754-2
Functional integrity test Thermal properties
According to IEC 60 331-11, IEC 60 331-25 and EN 50200
Transport/storage
– 25 °C to + 70 °C
Installation
– 5 °C to + 50 °C
Operating tempe-
– 20 °C to + 60 °C
90 min (VDE test report)
rature
Max. number of fibers
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
12 24
10.3 10.8
115 125
1.03 1.28
www.leoni-fiber-optics.com
09