Brochure glasvezelkabels voor marine en offshore

Page 1

FiberConnect®

FiberTech ®

FiberSwitch ®

FiberSplit®

Marine cables

265

FiberConnect® Universal cable with functional integrity 90 min

Outer jacket Out Strain relief elements / Str Out Outer fire protection barrier Rip cord

Fiber optic cables (SM / MM)

rodent-protected

Inner fire protection barrier Inn Loose tube, gel-filled Loo

GL U-D(ZN)BH n… FS

Functional integrity in the event of fire

Order no.

84 040 Q Q Q Q 222 ZGELO

Standardisation

IEC 60794-2

for at least 90 minutes

Description

Mechanical properties

Non-metallic, light and flexible cable with approval by Germani-

Min. bending radius static dynamic

scher Lloyd and Det Norske Veritas (DNV).

15 × outer diameter 20 × outer diameter

For fixed installation on ships and offshore facilities in safety-

Max. pull force

2500 N

related areas.

Max. crush resistance

3000 N/dm

Resistance to impacts

10 impacts/2 Nm

Composition Cable core

Loose tube, gel-filled

Fire performance

Inner fire protection barrier

Flame retardancy

IEC 60332-1-2 and IEC 60332-3-22 Cat. A

multifunctional, reinforced glass rovings

Smoke density

IEC 61034

as non-metallic strain relief elements

Absence of halogen IEC 60754-1

and rodent protection

Acidity of combus-

Cable jacket

Halogen-free, flame-retardant material

tion gases

Colour of jacket

O orange

Armour

IEC 60754-2

Functional integrity test Thermal properties

According to IEC 60 331-11, IEC 60 331-25 and EN 50200

Transport/storage

– 25 °C to + 70 °C

Installation

– 5 °C to + 50 °C

Operating tempe-

– 20 °C to + 60 °C

90 min (VDE test report)

rature

Max. number of fibers

Outer Ø

Weight

Fire load

mm

kg/km

MJ/m

12 24

10.3 10.8

115 125

1.03 1.28

www.leoni-fiber-optics.com

09


Turn static files into dynamic content formats.

Create a flipbook