232
Outdoor cables
FiberConnect® Universal cable with functional integrity 90 min
Fiber optic cables (SM / MM)
rodent protected , with central multi-fiber loose tube (2500 N)
Outer jacket Loose tube, gel-filled Rip cord inner fire protection tape Strain relief elements and rodent protection/outer fire protection tape
Functional integrity in the event of fire
U-D(ZN)BH n…FS Order no.
84 040 Q Q Q Q
Standardisation
IEC 60794-2
for at least 90 minutes
Description
Mechanical properties
Non-metallic, light and flexible cable with increased tensile
Min. bending radius static dynamic
strength that can be used both inside and outside buildings. Installation in cable ducts, on cable trays or in cable conduits.
15 × outer diameter 20 × outer diameter
Max. pull force on jacket
2500 N
Max. crush resistance
3000 N/dm
Composition Cable core
Loose tube, gel-filled
Fire performance
inner fire protection tape
Flame retardancy
IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Multifunctional reinforced glass rovings,
Smoke density
IEC 61034
moisture blocking, as non-metallic strain
Absence of halogen IEC 60754-1
relief elements and rodent protection
Acidity of combus-
Cable jacket
Halogen-free, flame-retardant material
tion gases
Colour of jacket
O blue
Armour
IEC 60754-2
Functional integrity test Acc. to IEC 60 331-11, IEC 60 331-25 and EN 50200
Thermal properties
09
Transport/storage
– 25 °C to + 70 °C
Installation
– 5 °C to + 50 °C
Operating tempe-
– 20 °C to + 60 °C
90 min (VDE test report).
rature
Max. number of fibers
12 24
Outer Ø
Weight
Fire load
mm
kg/km
MJ/m
10.3 10.8
115 125
1.03 1.28